Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36.763
Filtrar
1.
J Agric Food Chem ; 72(19): 11241-11250, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38709728

RESUMEN

The fungicide phenamacril has been employed to manage Fusarium and mycotoxins in crops, leading to persistent residues in the environment and plants. Detecting phenamacril is pivotal for ensuring environmental and food safety. In this study, haptens and artificial antigens were synthesized to produce antiphenamacril monoclonal antibodies (mAbs). Additionally, gold nanoparticles coated with a polydopamine shell were synthesized and conjugated with mAbs, inducing fluorescence quenching in quantum dots. Moreover, a dual-readout immunochromatographic assay that combines the positive signal from fluorescence with the negative signal from colorimetry was developed to enable sensitive and precise detection of phenamacril within 10 min, achieving detection limits of 5 ng/mL. The method's reliability was affirmed by using spiked wheat flour samples, achieving a limit of quantitation of 0.05 mg/kg. This analytical platform demonstrates high sensitivity, outstanding accuracy, and robust tolerance to matrix effects, making it suitable for the rapid, onsite, quantitative screening of phenamacril residues.


Asunto(s)
Colorimetría , Contaminación de Alimentos , Fungicidas Industriales , Residuos de Plaguicidas , Fungicidas Industriales/análisis , Contaminación de Alimentos/análisis , Colorimetría/métodos , Residuos de Plaguicidas/análisis , Anticuerpos Monoclonales/química , Cromatografía de Afinidad/métodos , Cromatografía de Afinidad/instrumentación , Fluorescencia , Triticum/química , Nanopartículas del Metal/química , Oro/química , Límite de Detección , Harina/análisis
2.
Se Pu ; 42(5): 410-419, 2024 Apr 08.
Artículo en Chino | MEDLINE | ID: mdl-38736384

RESUMEN

Protein A affinity chromatographic materials are widely used in clinical medicine and biomedicine because of their specific interactions with immunoglobulin G (IgG). Both the characteristics of the matrix, such as its structure and morphology, and the surface modification method contribute to the affinity properties of the packing materials. The specific, orderly, and oriented immobilization of protein A can reduce its steric hindrance with the matrix and preserve its bioactive sites. In this study, four types of affinity chromatographic materials were obtained using agarose and polyglycidyl methacrylate (PGMA) spheres as substrates, and multifunctional epoxy and maleimide groups were used to fix protein A. The effects of the ethylenediamine concentration, reaction pH, buffer concentration, and other conditions on the coupling efficiency of protein A and adsorption performance of IgG were evaluated. Multifunctional epoxy materials were prepared by converting part of the epoxy groups of the agarose and PGMA matrices into amino groups using 0.2 and 1.6 mol/L ethylenediamine, respectively. Protein A was coupled to the multifunctional epoxy materials using 5 mmol/L borate buffer (pH 8) as the reaction solution. When protein A was immobilized on the substrates by maleimide groups, the agarose and PGMA substrates were activated with 25% (v/v) ethylenediamine for 16 h to convert all epoxy groups into amino groups. The maleimide materials were then converted into amino-modified materials by adding 3 mg/mL 3-maleimidobenzoyl-N-hydroxysuccinimide ester (MBS) dissolved in dimethyl sulfoxide (DMSO) and then suspended in 5 mmol/L borate buffer (pH 8). The maleimide groups reacted specifically with the C-terminal of the sulfhydryl group of recombinant protein A to achieve highly selective fixation on both the agarose and PGMA substrates. The adsorption performance of the affinity materials for IgG was improved by optimizing the bonding conditions of protein A, such as the matrix type, matrix particle size, and protein A content, and the adsorption properties of each affinity material for IgG were determined. The column pressure of the protein A affinity materials prepared using agarose or PGMA as the matrix via the maleimide method was subsequently evaluated at different flow rates. The affinity materials prepared with PGMA as the matrix exhibited superior mechanical strength compared with the materials prepared with agarose. Moreover, an excellent linear relationship between the flow rate and column pressure of 80 mL/min was observed for this affinity material. Subsequently, the effect of the particle size of the PGMA matrix on the binding capacity of IgG was investigated. Under the same protein A content, the dynamic binding capacity of the affinity materials on the PGMA matrix was higher when the particle size was 44-88 µm than when other particle sizes were used. The properties of the affinity materials prepared using the multifunctional epoxy and maleimide-modified materials were compared by synthesizing affinity materials with different protein A coupling amounts of 1, 2, 4, 6, 8, and 10 mg/mL. The dynamic and static binding capacities of each material for bovine IgG were then determined. The prepared affinity material was packed into a chromatographic column to purify IgG from bovine colostrum. Although all materials showed specific adsorption selectivity for IgG, the affinity material prepared by immobilizing protein A on the PGMA matrix with maleimide showed significantly better performance and achieved a higher dynamic binding capacity at a lower protein grafting amount. When the protein grafting amount was 15.71 mg/mL, the dynamic binding capacity of bovine IgG was 32.23 mg/mL, and the dynamic binding capacity of human IgG reached 54.41 mg/mL. After 160 cycles of alkali treatment, the dynamic binding capacity of the material reached 94.6% of the initial value, indicating its good stability. The developed method is appropriate for the production of protein A affinity chromatographic materials and shows great potential in the fields of protein immobilization and immunoadsorption material synthesis.


Asunto(s)
Cromatografía de Afinidad , Proteína Estafilocócica A , Cromatografía de Afinidad/métodos , Proteína Estafilocócica A/química , Adsorción , Inmunoglobulina G/química , Ácidos Polimetacrílicos/química , Sefarosa/química
3.
Mikrochim Acta ; 191(6): 311, 2024 05 08.
Artículo en Inglés | MEDLINE | ID: mdl-38717575

RESUMEN

Urine retinol-binding protein 4 (RBP4) has recently been reported as a novel earlier biomarker of chronic kidney disease (CKD) which is a global public health problem with high morbidity and mortality. Accurate and rapid detection of urine RBP4 is essential for early monitor of impaired kidney function and prevention of CKD progression. In the present study, we developed a time-resolved fluorescence immunochromatographic test strip (TRFIS) for the quantitative and rapid detection of urine RBP4. This TRFIS possessed excellent linearity ranging from 0.024 to 12.50 ng/mL for the detection of urine RBP4, and displayed a good linearity (Y = 239,581 × X + 617,238, R2 = 0.9902), with the lowest visual detection limit of 0.049 ng/mL. This TRFIS allows for quantitative detection of urine RBP4 within 15 min and shows high specificity. The intra-batch coefficient of variation (CV) and the inter-batch CV were both < 8%, respectively. Additionally, this TRFIS was applied to detect RBP4 in the urine samples from healthy donors and patients with CKD, and the results of TRFIS could efficiently discern the patients with CKD from the healthy donors. The developed TRFIS has the characteristics of high sensitivity, high accuracy, and a wide linear range, and is suitable for rapid and quantitative determination of urine RBP4.


Asunto(s)
Cromatografía de Afinidad , Insuficiencia Renal Crónica , Proteínas Plasmáticas de Unión al Retinol , Humanos , Proteínas Plasmáticas de Unión al Retinol/orina , Cromatografía de Afinidad/métodos , Insuficiencia Renal Crónica/orina , Insuficiencia Renal Crónica/diagnóstico , Límite de Detección , Tiras Reactivas , Biomarcadores/orina , Inmunoensayo/métodos
4.
Methods Mol Biol ; 2799: 13-27, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38727900

RESUMEN

N-methyl-D-aspartate (NMDA) receptors are critical for brain function and serve as drug targets for the treatment of neurological and psychiatric disorders. They typically form the tetrameric assembly of GluN1-GluN2 (2A to 2D) subtypes, with their diverse three-dimensional conformations linked with the physiologically relevant function in vivo. Purified proteins of tetrameric assembled NMDA receptors have broad applications in the structural elucidation, hybridoma technology for antibody production, and high-throughput drug screening. However, obtaining sufficient quantity and monodisperse NMDA receptor protein is still technically challenging. Here, we summarize a paradigm for the expression and purification of diverse NMDA receptor subtypes, with detailed descriptions on screening constructs by fluorescence size-exclusion chromatography (FSEC), generation of recombinant baculovirus, expression in the eukaryotic expression system, protein purification by affinity chromatography and size-exclusion chromatography (SEC), biochemical and functional validation assays.


Asunto(s)
Baculoviridae , Cromatografía de Afinidad , Cromatografía en Gel , Receptores de N-Metil-D-Aspartato , Receptores de N-Metil-D-Aspartato/metabolismo , Receptores de N-Metil-D-Aspartato/genética , Receptores de N-Metil-D-Aspartato/aislamiento & purificación , Receptores de N-Metil-D-Aspartato/química , Animales , Baculoviridae/genética , Cromatografía de Afinidad/métodos , Humanos , Proteínas Recombinantes/aislamiento & purificación , Proteínas Recombinantes/genética , Proteínas Recombinantes/metabolismo , Expresión Génica , Células Sf9
5.
Anal Chim Acta ; 1306: 342513, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38692783

RESUMEN

Over the past decades, the proteomics field has undergone rapid growth. Progress in mass spectrometry and bioinformatics, together with separation methods, has brought many innovative approaches to the study of the molecular biology of the cell. The potential of affinity chromatography was recognized immediately after its first application in proteomics, and since that time, it has become one of the cornerstones of many proteomic protocols. Indeed, this chromatographic technique exploiting the specific binding between two molecules has been employed for numerous purposes, from selective removal of interfering (over)abundant proteins or enrichment of scarce biomarkers in complex biological samples to mapping the post-translational modifications and protein interactions with other proteins, nucleic acids or biologically active small molecules. This review presents a comprehensive survey of this versatile analytical tool in current proteomics. To navigate the reader, the haphazard space of affinity separations is classified according to the experiment's aims and the separated molecule's nature. Different types of available ligands and experimental strategies are discussed in further detail for each of the mentioned procedures.


Asunto(s)
Cromatografía de Afinidad , Proteómica , Cromatografía de Afinidad/métodos , Proteómica/métodos , Humanos , Proteínas/aislamiento & purificación , Proteínas/análisis , Proteínas/química
6.
Mikrochim Acta ; 191(6): 325, 2024 05 13.
Artículo en Inglés | MEDLINE | ID: mdl-38739279

RESUMEN

Glial fibrillary acidic protein (GFAP) in serum has been shown as a biomarker of traumatic brain injury (TBI) which is a significant global public health concern. Accurate and rapid detection of serum GFAP is critical for TBI diagnosis. In this study, a time-resolved fluorescence immunochromatographic test strip (TRFIS) was proposed for the quantitative detection of serum GFAP. This TRFIS possessed excellent linearity ranging from 0.05 to 2.5 ng/mL for the detection of serum GFAP and displayed good linearity (Y = 598723X + 797198, R2 = 0.99), with the lowest detection limit of 16 pg/mL. This TRFIS allowed for quantitative detection of serum GFAP within 15 min and showed high specificity. The intra-batch coefficient of variation (CV) and the inter-batch CV were both < 4.0%. Additionally, this TRFIS was applied to detect GFAP in the serum samples from healthy donors and patients with cerebral hemorrhage, and the results of TRFIS could efficiently discern the patients with cerebral hemorrhage from the healthy donors. Our developed TRFIS has the characteristics of high sensitivity, high accuracy, and a wide linear range and is suitable for rapid and quantitative determination of serum GFAP on-site.


Asunto(s)
Cromatografía de Afinidad , Proteína Ácida Fibrilar de la Glía , Límite de Detección , Proteína Ácida Fibrilar de la Glía/sangre , Humanos , Cromatografía de Afinidad/métodos , Tiras Reactivas , Hemorragia Cerebral/sangre , Hemorragia Cerebral/diagnóstico , Biomarcadores/sangre
7.
J Vis Exp ; (206)2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38738876

RESUMEN

Functional characterization of proteins requires them to be expressed and purified in substantial amounts with high purity to perform biochemical assays. The Fast Protein Liquid Chromatography (FPLC) system allows high-resolution separation of complex protein mixtures. By adjusting various parameters in FPLC, such as selecting the appropriate purification matrix, regulating the protein sample's temperature, and managing the sample's flow rate onto the matrix and the elution rate, it is possible to ensure the protein's stability and functionality. In this protocol, we will demonstrate the versatility of the FPLC system to purify 6X-His-tagged flap endonuclease 1 (FEN1) protein, produced in bacterial cultures. To improve protein purification efficiency, we will focus on multiple considerations, including proper column packing and preparation, sample injection using a sample loop, flow rate of sample application to the column, and sample elution parameters. Finally, the chromatogram will be analyzed to identify fractions containing high yields of protein and considerations for proper recombinant protein long-term storage. Optimizing protein purification methods is crucial for improving the precision and reliability of protein analysis.


Asunto(s)
Cromatografía de Afinidad , Cromatografía de Afinidad/métodos , Endonucleasas de ADN Solapado/química , Endonucleasas de ADN Solapado/aislamiento & purificación , Endonucleasas de ADN Solapado/metabolismo , Cromatografía Liquida/métodos , Histidina/química , Escherichia coli/genética , Escherichia coli/química , Escherichia coli/metabolismo , Oligopéptidos/química , Oligopéptidos/aislamiento & purificación , Proteínas Recombinantes de Fusión/química , Proteínas Recombinantes de Fusión/aislamiento & purificación , Proteínas Recombinantes de Fusión/genética , Proteínas Recombinantes de Fusión/metabolismo
8.
J Chromatogr A ; 1722: 464902, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38636150

RESUMEN

Although immobilized metal ion affinity chromatography (IMAC) is one of the most effective methods for purifying his-tagged proteins, it has limitations such as expensive commercial resins and non-specific binding of unwanted proteins to the nickel immobilized on the resin. In this study, biocompatible chitosan and porous chitosan membranes as alternative resins were synthesized for protein immobilization and purification, but finally porous chitosan membrane was selected due to its higher porosity and consequently higher nickel adsorption. Once the membrane was functionalized with nickel ions and its metal adsorption confirmed by EDS and ICP methods, it was used to immobilize and purify recombinant ß-NGF as a protein model with his-tag tail in batch-fashion. Protein binding and purification were also approved by FTIR and UV-Vis spectroscopy and SDS-PAGE technique. Our results indicated that the protein of interest could bind to the nickel-functionalized porous chitosan membrane with high efficiency at pH=7. Furthermore, for protein purification, the pH value of 6 and an imidazole concentration of 750 mM were suggested for the final elution buffer. In conclusion, nickel-functionalized porous chitosan membrane could be a suitable alternative to IMAC for low cost and specific protein immobilization and purification.


Asunto(s)
Quitosano , Cromatografía de Afinidad , Histidina , Membranas Artificiales , Níquel , Níquel/química , Quitosano/química , Cromatografía de Afinidad/métodos , Histidina/química , Porosidad , Adsorción , Proteínas Inmovilizadas/química , Concentración de Iones de Hidrógeno , Proteínas Recombinantes/química , Proteínas Recombinantes/aislamiento & purificación
9.
Molecules ; 29(7)2024 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-38611935

RESUMEN

Immobilized metal ion affinity chromatography (IMAC) adsorbents generally have excellent affinity for histidine-rich proteins. However, the leaching of metal ions from the adsorbent usually affects its adsorption performance, which greatly affects the reusable performance of the adsorbent, resulting in many limitations in practical applications. Herein, a novel IMAC adsorbent, i.e., Cu(II)-loaded polydopamine-coated urchin-like titanate microspheres (Cu-PDA-UTMS), was prepared via metal coordination to make Cu ions uniformly decorate polydopamine-coated titanate microspheres. The as-synthesized microspheres exhibit an urchin-like structure, providing more binding sites for hemoglobin. Cu-PDA-UTMS exhibit favorable selectivity for hemoglobin adsorption and have a desirable adsorption capacity towards hemoglobin up to 2704.6 mg g-1. Using 0.1% CTAB as eluent, the adsorbed hemoglobin was easily eluted with a recovery rate of 86.8%. In addition, Cu-PDA-UTMS shows good reusability up to six cycles. In the end, the adsorption properties by Cu-PDA-UTMS towards hemoglobin from human blood samples were analyzed by SDS-PAGE. The results showed that Cu-PDA-UTMS are a high-performance IMAC adsorbent for hemoglobin separation, which provides a new method for the effective separation and purification of hemoglobin from complex biological samples.


Asunto(s)
Hemoglobinas , Imidazoles , Indoles , Polímeros , Humanos , Microesferas , Cromatografía de Afinidad , Iones
10.
Sci Rep ; 14(1): 8938, 2024 04 18.
Artículo en Inglés | MEDLINE | ID: mdl-38637629

RESUMEN

Heart failure is a serious medical condition with a poor prognosis. Current treatments can only help manage the symptoms and slow the progression of heart failure. However, there is currently no cure to prevent and reverse cardiac remodeling. Transcription factors are in a central role in various cellular processes, and in the heart, GATA4 and NKX2-5 transcription factors mediate hypertrophic responses and remodeling. We have identified compounds that modulate the synergistic interaction of GATA4 and NKX2-5 and shown that the most promising compound (1, 3i-1000) is cardioprotective in vitro and in vivo. However, direct evidence of its binding site and mechanism of action has not been available. Due to the disordered nature of transcription factors, classical target engagement approaches cannot be utilized. Here, we synthesized a small-molecule ligand-binding pulldown probe of compound 1 to utilize affinity chromatography alongside CETSA, AlphaScreen, and molecular modeling to study ligand binding. These results provide the first evidence of direct physical binding of compound 1 selectively to GATA4. While developing drugs that target transcription factors presents challenges, advances in technologies and knowledge of intrinsically disordered proteins enable the identification of small molecules that can selectively target transcription factors.


Asunto(s)
Insuficiencia Cardíaca , Factores de Transcripción , Humanos , Proteína Homeótica Nkx-2.5/metabolismo , Ligandos , Factores de Transcripción/metabolismo , Cromatografía de Afinidad , Factor de Transcripción GATA4/metabolismo , Proteínas de Homeodominio/metabolismo
11.
J Chromatogr A ; 1722: 464890, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38598892

RESUMEN

The rapidly growing market of monoclonal antibodies (mAbs) within the biopharmaceutical industry has incentivised numerous works on the design of more efficient production processes. Protein A affinity chromatography is regarded as one of the best processes for the capture of mAbs. Although the screening of Protein A resins has been previously examined, process flexibility has not been considered to date. Examining performance alongside flexibility is crucial for the design of processes that can handle disturbances arising from the feed stream. In this work, we present a model-based approach for the identification of design spaces, enhanced by machine learning. We demonstrate its capabilities on the design of a Protein A chromatography unit, screening five industrially relevant resins. The computational results favourably compare to experimental data and a resin performance comparison is presented. An improvement on the computational time by a factor of 300,000 is achieved using the machine learning aided methodology. This allowed for the identification of 5,120 different design spaces in only 19 h.


Asunto(s)
Anticuerpos Monoclonales , Cromatografía de Afinidad , Diseño Asistido por Computadora , Aprendizaje Automático , Proteína Estafilocócica A , Cromatografía de Afinidad/métodos , Anticuerpos Monoclonales/química , Proteína Estafilocócica A/química
12.
J Chromatogr A ; 1722: 464891, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38608368

RESUMEN

Particle size is a critical parameter of chromatographic resins that significantly affects protein separation. In this study, effects of resin particle sizes (31.26 µm, 59.85 µm and 85.22 µm named Aga-31, Aga-60 and Aga-85, respectively) on antibody adsorption capacity and separation performance of a hybrid biomimetic ligand were evaluated. Their performance was investigated through static adsorption and breakthrough assays to quantify static and dynamic binding capacity (Qmax and DBC). The static adsorption results revealed that the Qmax for hIgG was 152 mg/g resin with Aga-31, 151 mg/g resin with Aga-60, and 125 mg/g resin with Aga-85. Moreover, the DBC at 10% breakthrough for hIgG with a residence time of 2 min was determined to be 49.4 mg/mL for Aga-31, 45.9 mg/mL for Aga-60, and 38.9 mg/mL for Aga-85. The resins with smaller particle sizes exhibited significantly higher capacity compared to typical commercial agarose resins and a Protein A resin (MabSelect SuRe). Furthermore, the Aga-31 resin with the hybrid biomimetic ligand demonstrated exceptional performance in terms of IgG purity (>98%) and recovery (>96%) after undergoing 20 separation cycles from CHO cell supernatant. These findings are helpful in further chromatographic resin design for the industrial application of antibody separation and purification.


Asunto(s)
Inmunoglobulina G , Tamaño de la Partícula , Adsorción , Ligandos , Inmunoglobulina G/química , Inmunoglobulina G/aislamiento & purificación , Cromatografía de Afinidad/métodos , Materiales Biomiméticos/química , Animales , Biomimética/métodos , Cricetulus , Células CHO
13.
J Chromatogr A ; 1722: 464873, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38626540

RESUMEN

3D printing offers the unprecedented ability to fabricate chromatography stationary phases with bespoke 3D morphology as opposed to traditional packed beds of spherical beads. The restricted range of printable materials compatible with chromatography is considered a setback for its industrial implementation. Recently, we proposed a novel ink that exhibits favourable printing performance (printing time ∼100 mL/h, resolution ∼200 µm) and broadens the possibilities for a range of chromatography applications thanks to its customisable surface chemistry. In this work, this ink was used to fabricate 3D printed ordered columns with 300 µm channels for the capture and polishing of therapeutic monoclonal antibodies. The columns were initially assessed for leachables and extractables, revealing no material propensity for leaching. Columns were then functionalised with protein A and SO3 ligands to obtain affinity and strong cation exchangers, respectively. 3D printed protein A columns showed >85 % IgG recovery from harvested cell culture fluid with purities above 98 %. Column reusability was evaluated over 20 cycles showing unaffected performance. Eluate samples were analysed for co-eluted protein A fragments, host cell protein and aggregates. Results demonstrate excellent HCP clearance (logarithmic reduction value of > 2.5) and protein A leakage in the range of commercial affinity resins (<100 ng/mg). SO3 functionalised columns employed for polishing achieved removal of leaked Protein A (down to 10 ng/mg) to meet regulatory expectations of product purity. This work is the first implementation of 3D printed columns for mAb purification and provides strong evidence for their potential in industrial bioseparations.


Asunto(s)
Anticuerpos Monoclonales , Cricetulus , Inmunoglobulina G , Impresión Tridimensional , Proteína Estafilocócica A , Anticuerpos Monoclonales/aislamiento & purificación , Anticuerpos Monoclonales/química , Proteína Estafilocócica A/química , Inmunoglobulina G/aislamiento & purificación , Inmunoglobulina G/química , Células CHO , Cromatografía de Afinidad/métodos , Animales , Cromatografía por Intercambio Iónico/métodos , Tinta
14.
Analyst ; 149(9): 2747-2755, 2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38563739

RESUMEN

Avian leukemia is an infectious tumorous disease of chickens caused by subgroup A of the avian leukemia virus (ALV-A), which mainly causes long-term viremia, slow growth, immune suppression, decreased production performance, multi-tissue tumors, and even death. The infection rate of this disease is very high in chicken herds in China, causing huge economic losses to the poultry industry every year. We successfully expressed the specific antigen protein of ALV (P27) through recombinant protein technology and screened a pair of highly sensitive monoclonal antibodies (mAbs) through mouse immunity, cell fusion, and antibody pairing. Based on this pair of antibodies, we established a dual antibody sandwich ELISA and gold nanoparticle immunochromatographic strip (AuNP-ICS) detection method. In addition, the parameters of the dual antibody sandwich ELISA and AuNP-ICS were optimized under different reaction conditions, which resulted in the minimum detection limits of 0.2 ng mL-1 and 1.53 ng ml-1, respectively. Commonly available ELISA and AuNP-ICS products on the market were compared, and we found that our established immune rapid chromatography had higher sensitivity. This established AuNP-ICS had no cross-reactivity with Influenza A (H1N1), Influenza A (H9N2), respiratory syncytial virus (RSV), varicella-zoster virus (VZV), Listeria monocytogenes listeriolysin (LLO), and Staphylococcal enterotoxin SED or SEC. Finally, the established AuNP-ICS was used to analyze 35 egg samples, and the results showed 5 positive samples and 30 negative samples. The AuNP-ICS rapid detection method established by our group had good specificity, high sensitivity, and convenience, and could be applied to the clinical sample detection of ALV-A.


Asunto(s)
Virus de la Leucosis Aviar , Cromatografía de Afinidad , Ensayo de Inmunoadsorción Enzimática , Oro , Nanopartículas del Metal , Oro/química , Nanopartículas del Metal/química , Animales , Virus de la Leucosis Aviar/aislamiento & purificación , Virus de la Leucosis Aviar/inmunología , Cromatografía de Afinidad/métodos , Ensayo de Inmunoadsorción Enzimática/métodos , Antígenos Virales/inmunología , Antígenos Virales/análisis , Clara de Huevo/química , Tiras Reactivas , Pollos , Límite de Detección , Ratones , Anticuerpos Monoclonales/inmunología , Anticuerpos Monoclonales/química
15.
Sci Rep ; 14(1): 8714, 2024 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-38622266

RESUMEN

Green, photosynthesizing plants can be proficiently used as cost-effective, single-use, fully biodegradable bioreactors for environmentally-friendly production of a variety of valuable recombinant proteins. Being near-infinitely scalable and most energy-efficient in generating biomass, plants represent profoundly valid alternatives to conventionally used stationary fermenters. To validate this, we produced a plastome-engineered tobacco bioreactor line expressing a recombinant variant of the protein A from Staphylococcus aureus, an affinity ligand widely useful in antibody purification processes, reaching accumulation levels up to ~ 250 mg per 1 kg of fresh leaf biomass. Chromatography resin manufactured from photosynthetically-sourced recombinant protein A ligand conjugated to agarose beads demonstrated the innate pH-driven ability to bind and elute IgG-type antibodies and allowed one-step efficient purification of functional monoclonal antibodies from the supernatants of the producing hybridomas. The results of this study emphasize the versatility of plant-based recombinant protein production and illustrate its vast potential in reducing the cost of diverse biotechnological applications, particularly the downstream processing and purification of monoclonal antibodies.


Asunto(s)
Cromatografía , Proteína Estafilocócica A , Proteína Estafilocócica A/química , Ligandos , Plantas Modificadas Genéticamente/metabolismo , Proteínas Recombinantes/genética , Proteínas Recombinantes/metabolismo , Anticuerpos Monoclonales/metabolismo , Inmunoglobulina G/metabolismo , Proteínas de Plantas/metabolismo , Cromatografía de Afinidad/métodos
16.
Appl Microbiol Biotechnol ; 108(1): 283, 2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38573435

RESUMEN

Porcine reproductive and respiratory syndrome (PRRS) is an immunosuppressive disease caused by the porcine reproductive and respiratory syndrome virus (PRRSV). Current vaccine prevention and treatment approaches for PRRS are not adequate, and commercial vaccines do not provide sufficient cross-immune protection. Therefore, establishing a precise, sensitive, simple, and rapid serological diagnostic approach for detecting PRRSV antibodies is crucial. The present study used quantum dot fluorescent microspheres (QDFM) as tracers, covalently linked to the PRRSV N protein, to develop an immunochromatography strip (ICS) for detecting PRRSV antibodies. Monoclonal antibodies against PRRSV nucleocapsid (N) and membrane (M) proteins were both coated on nitrocellulose membranes as control (C) and test (T) lines, respectively. QDFM ICS identified PRRSV antibodies under 10 min with high sensitivity and specificity. The specificity assay revealed no cross-reactivity with the other tested viruses. The sensitivity assay revealed that the minimum detection limit was 1.2 ng/mL when the maximum dilution was 1:2,048, comparable to the sensitivity of enzyme-linked immunosorbent assay (ELISA) kits. Moreover, compared to PRRSV ELISA antibody detection kits, the sensitivity, specificity, and accuracy of QDFM ICS after analyzing 189 clinical samples were 96.7%, 97.9%, and 97.4%, respectively. Notably, the test strips can be stored for up to 6 months at 4 °C and up to 4 months at room temperature (18-25 °C). In conclusion, QDFM ICS offers the advantages of rapid detection time, high specificity and sensitivity, and affordability, indicating its potential for on-site PRRS screening. KEY POINTS: • QDFM ICS is a novel method for on-site and in-lab detection of PRRSV antibodies • Its sensitivity, specificity, and accuracy are on par with commercial ELISA kits • QDFM ICS rapidly identifies PRRSV, aiding the swine industry address the evolving virus.


Asunto(s)
Síndrome Respiratorio y de la Reproducción Porcina , Virus del Síndrome Respiratorio y Reproductivo Porcino , Puntos Cuánticos , Animales , Porcinos , Microesferas , Síndrome Respiratorio y de la Reproducción Porcina/diagnóstico , Colorantes , Anticuerpos Antivirales , Cromatografía de Afinidad
17.
J Vis Exp ; (206)2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38647283

RESUMEN

Adeno-associated virus (AAV) has become an increasingly valuable vector for in vivo gene delivery and is currently undergoing human clinical trials. However, the commonly used methods to purify AAVs make use of cesium chloride or iodixanol density gradient ultracentrifugation. Despite their advantages, these methods are time-consuming, have limited scalability, and often result in vectors with low purity. To overcome these constraints, researchers are turning their attention to chromatography techniques. Here, we present an optimized heparin-based affinity chromatography protocol that serves as a universal capture step for the purification of AAVs. This method relies on the intrinsic affinity of AAV serotype 2 (AAV2) for heparan sulfate proteoglycans. Specifically, the protocol entails the co-transfection of plasmids encoding the desired AAV capsid proteins with those of AAV2, yielding mosaic AAV vectors that combine the properties of both parental serotypes. Briefly, after the lysis of producer cells, a mixture containing AAV particles is directly purified following an optimized single-step heparin affinity chromatography protocol using a standard fast protein liquid chromatography (FPLC) system. Purified AAV particles are subsequently concentrated and subjected to comprehensive characterization in terms of purity and biological activity. This protocol offers a simplified and scalable approach that can be performed without the need for ultracentrifugation and gradients, yielding clean and high viral titers.


Asunto(s)
Cromatografía de Afinidad , Dependovirus , Vectores Genéticos , Heparina , Dependovirus/genética , Dependovirus/aislamiento & purificación , Dependovirus/química , Cromatografía de Afinidad/métodos , Heparina/química , Vectores Genéticos/química , Vectores Genéticos/genética , Humanos , Células HEK293
18.
J Chromatogr A ; 1723: 464912, 2024 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-38643740

RESUMEN

Since the outbreak of coronavirus disease 2019, the global demand for vaccines has increased rapidly to prevent infection and protect high-risk populations. However, identifying viral mutations poses an additional challenge for chromatographic purification of vaccines and subunit vaccines. In this study, a new affinity peptide model, X1VX2GLNX3WX4RYSK, was established, and a library of 612 peptides was generated for ligand screening. Based on a multistep strategy of ligand screening, 18 candidate peptides were obtained. The top ranking peptide, LP14 (YVYGLNIWLRYSK), and two other representative peptides, LP02 and LP06, with lower rankings were compared via molecular dynamics simulation. The results revealed that peptide binding to the receptor binding domain (RBD) was driven by hydrophobic interactions and the key residues involved in the binding were identified. Surface plasmon resonance analysis further confirmed that LP14 had the highest affinity for the wild RBD (Kd=0.520 µmol/L), and viral mutation had little influence on the affinity of LP14, demonstrating its great potential as a broad-spectrum ligand for RBD purification. Finally, chromatographic performance of LP14-coupled gel-packed column verified that both wild and omicron RBDs could be purified and were eluted by 0.1 mol/L Gly-HCl buffer (pH 3.0). This research identified a broad-spectrum peptide for RBD purification based on rational design and demonstrated its potential application in the purification of RBDs from complex feedstock.


Asunto(s)
Péptidos , Glicoproteína de la Espiga del Coronavirus , Glicoproteína de la Espiga del Coronavirus/química , Glicoproteína de la Espiga del Coronavirus/aislamiento & purificación , Glicoproteína de la Espiga del Coronavirus/metabolismo , Ligandos , Péptidos/química , Péptidos/aislamiento & purificación , Simulación de Dinámica Molecular , Humanos , SARS-CoV-2/química , SARS-CoV-2/aislamiento & purificación , Unión Proteica , COVID-19/virología , Cromatografía de Afinidad/métodos , Resonancia por Plasmón de Superficie
19.
PDA J Pharm Sci Technol ; 78(2): 147-156, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38609153

RESUMEN

This session deals with the rational design of viral clearance studies for biopharmaceuticals including recombinant proteins such as monoclonal antibodies and, as new in scope of the symposium, also viral clearance for adeno-associated viral (AAV) vectors. For recombinant proteins, large datasets were accumulated over the last decades and are intended to be used for accelerated product process development and streamlining of viral clearance studies. How to utilize prior knowledge in viral clearance validation and how it can be used in a risk assessment tool to decide whether additional virus clearance studies are necessary during product development is being addressed by three of the presentations of this session. This also includes an a priori intended design and generation of validation data for a new kind of detergent such as CG-110, to build up a platform dataset to be used as prior knowledge in future marketing application. Another presentation investigates the virus removal mechanism of a newly developed hydrophobic interaction chromatography (HIC) resin and demonstrates for highly hydrophobic antibodies appropriate reduction for a retrovirus and impurities in a defined process range in contrast to the moderate to poor virus reduction of recent HIC resins. The last two presentations deal with virus clearance approaches for AAV, which will become mandatory with approval of the ICH Q5A revision. Appropriate virus removal and virus inactivation procedures can be implemented into the manufacturing processes of AAV vectors including viral filtration, viral inactivation (e.g., heat inactivation), affinity chromatography, and anion-exchange chromatography with which it seems possible to achieve a good clearance for helper and also adventitious viruses. The heat treatment step can be even a robust step for adenovirus helper inactivation for AAV products when product characteristics and process conditions are understood.


Asunto(s)
Anticuerpos Monoclonales , Productos Biológicos , Cromatografía de Afinidad , Comercio , Proteínas Recombinantes
20.
Artículo en Inglés | MEDLINE | ID: mdl-38663075

RESUMEN

In this Part IV of the article series dealing with the functionalization of the precursor carboxy silica with various chromatographic ligands, immuno affinity (IA) columns were prepared with immobilized anti-apolipoprotein B (AAP B) and anti-haptoglobin (AHP) antibodies for use in immuno affinity chromatography (IAC) in the aim of selectivily capturing their corresponding antigens from healthy and cancer human sera. Diseased human serum with adenocarcinoma cancer was selected as a typical diseased biological fluid. Besides preferentially capturing their corresponding antigens, the AAP B column captured from disease-free and cancer sera, 34 proteins and 33 proteins, respectively, while the AHP column enriched 38 and 47 proteins, respectively. This nonspecific binding can be attributed to the many proteins human serum have, which could mediate protein-protein interactions thus leading to the so-called "sponge effect". This kind of behavior can be exploited positively in the determination of differentially expressed proteins (DEPs) for diseased serum with respect to healthy serum and in turn allow the identification of an array of potential biomarkers for cancer. In fact, For AHP column, 13 upregulated and 22 downregulated proteins were identified whereas for AAP B column the numbers were 23 and 10, respectively. The DEPs identified with both columns match those reported in the literature for other types of cancers. The different expression of proteins in each IAC column can be related to the variability of protein-protein interactions. In addition, an array of a few biomarkers is more indicative of a certain disease than a single biomarker.


Asunto(s)
Anticuerpos Inmovilizados , Cromatografía de Afinidad , Dióxido de Silicio , Humanos , Cromatografía de Afinidad/métodos , Anticuerpos Inmovilizados/química , Anticuerpos Inmovilizados/inmunología , Dióxido de Silicio/química , Ligandos , Cromatografía Líquida de Alta Presión/métodos , Proteínas Sanguíneas/química , Biomarcadores de Tumor/sangre
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...