Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.828
Filtrar
1.
Swiss Dent J ; 134(2): 53-71, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38739770

RESUMEN

Oral healthcare among the frail is an underestimated geriatric care element. While neglected oral health (OH) is a well-established risk factor for frailty, frailty can be a risk factor for subsequent OH problems. The cross-sectional investigation nested into the SAPALDIA sub-cohort of citizens aged 52 years and older, aims to stimulate longitudinal research into aspects that accelerate poor OH among frail individuals. The hypothesis investigated was that (pre-) frail individuals are more likely to have missing teeth replaced with removable dental prostheses (RDP) resulting in difficulties with chewing. The study included 1489 participants undergoing geriatric assessments and oral examination. The main predictor was frailty status (non-frail; pre-frail; frail), based on Fried's frailty phenotype. The main outcomes of interest were non-functional dentition (presence of ≤ 19 natural teeth), presence of any RDP and self-reported difficulties with chewing. Pre-frailty and frailty were not associated with the presence of ≤ 19 natural teeth, but were associated with a higher RDP prevalence. The presence of at least one complete denture (CD) had 1.71 fold and 2.54 folds higher odds among pre-frail and frail, respectively, compared to non-frail individuals. Frail individuals with CD reported chewing difficulties 7.8 times more often than non-frail individuals without CD. The results are in line with the hypothesis that (pre-) frail individuals may be more likely to have tooth loss restored by RDPs. Future longitudinal research needs to assess potential barriers to oral hygiene and fixed dental prostheses among (pre-) frail and to study their oral health-related quality of life.


Asunto(s)
Anciano Frágil , Masticación , Humanos , Anciano , Femenino , Masculino , Masticación/fisiología , Persona de Mediana Edad , Estudios Transversales , Suiza/epidemiología , Estudios de Cohortes , Anciano de 80 o más Años , Evaluación Geriátrica , Salud Bucal/estadística & datos numéricos , Fragilidad/epidemiología , Dentadura Parcial Removible , Dentadura Completa/efectos adversos
2.
Comput Biol Med ; 175: 108550, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38701590

RESUMEN

BACKGROUND AND OBJECTIVE: Complete denture is a common restorative treatment in dental patients and the design of the core components (major connector and retentive mesh) of complete denture metal base (CDMB) is the basis of successful restoration. However, the automated design process of CDMB has become a challenging task primarily due to the complexity of manual interaction, low personalization, and low design accuracy. METHODS: To solve the existing problems, we develop a computer-aided Segmentation Network-driven CDMB design framework, called CDMB-SegNet, to automatically generate personalized digital design boundaries for complete dentures of edentulous patients. Specifically, CDMB-SegNet consists of a novel upright-orientation adjustment module (UO-AM), a dental feature-driven segmentation network, and a specific boundary-optimization design module (BO-DM). UO-AM automatically identifies key points for locating spatial attitude of the three-dimensional dental model with arbitrary posture, while BO-DM can result in smoother and more personalized designs for complete denture. In addition, to achieve efficient and accurate feature extraction and segmentation of 3D edentulous models with irregular gingival tissues, the light-weight backbone network is also incorporated into CDMB-SegNet. RESULTS: Experimental results on a large clinical dataset showed that CDMB-SegNet can achieve superior performance over the state-of-the-art methods. Quantitative evaluation (major connector/retentive mesh) showed improved Accuracy (98.54 ± 0.58 %/97.73 ± 0.92 %) and IoU (87.42 ± 5.48 %/70.42 ± 7.95 %), and reduced Maximum Symmetric Surface Distance (4.54 ± 2.06 mm/4.62 ± 1.68 mm), Average Symmetric Surface Distance (1.45 ± 0.63mm/1.28 ± 0.54 mm), Roughness Rate (6.17 ± 1.40 %/6.80 ± 1.23 %) and Vertices Number (23.22 ± 1.85/43.15 ± 2.72). Moreover, CDMB-SegNet shortened the overall design time to around 4 min, which is one tenth of the comparison methods. CONCLUSIONS: CDMB-SegNet is the first intelligent neural network for automatic CDMB design driven by oral big data and dental features. The designed CDMB is able to couple with patient's personalized dental anatomical morphology, providing higher clinical applicability compared with the state-of-the-art methods.


Asunto(s)
Dentadura Completa , Humanos , Diseño de Dentadura/métodos , Redes Neurales de la Computación , Diseño Asistido por Computadora
3.
J Appl Oral Sci ; 32: e20230397, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38695444

RESUMEN

Specific products containing natural resources can contribute to the innovation of complete denture hygiene. OBJECTIVE: To conduct an in vitro evaluation of experimental dentifrices containing essential oils of Bowdichia virgilioides Kunth (BvK), Copaifera officinalis (Co), Eucalyptus citriodora (Ec), Melaleuca alternifolia (Ma) and Pinus strobus (Ps) at 1%. METHODOLOGY: The variables evaluated were organoleptic and physicochemical characteristics, abrasiveness (mechanical brushing machine) simulating 2.5 years, and microbial load (Colony Forming Units - CFU/mL), metabolic activity (XTT assay) and cell viability (Live/Dead® BacLight™ kit) of the multispecies biofilm (Streptococcus mutans: Sm, Staphylococcus aureus: Sa, Candida albicans: Ca and Candida glabrata: Cg). Specimens of heat-polymerized acrylic resins (n=256) (n=96 specimens for abrasiveness, n=72 for microbial load count, n=72 for biofilm metabolic activity, n=16 for cell viability and total biofilm quantification) with formed biofilm were divided into eight groups for manual brushing (20 seconds) with a dental brush and distilled water (NC: negative control), Trihydral (PC: positive control), placebo (Pl), BvK, Co, Ec, Ma or Ps. After brushing, the specimens were washed with PBS and immersed in Letheen Broth medium, and the suspension was sown in solid specific medium. The organoleptic characteristics were presented by descriptive analysis. The values of density, pH, consistency and viscosity were presented in a table. The data were analyzed with the Wald test in a generalized linear model, followed by the Kruskal-Wallis test, Dunn's test (mass change) and the Bonferroni test (UFC and XTT). The Wald test in Generalized Estimating Equations and the Bonferroni test were used to analyze cell viability. RESULTS: All dentifrices showed stable organoleptic characteristics and adequate physicochemical properties. CN, Ec, Ps, Pl and PC showed low abrasiveness. There was a significant difference between the groups (p<0.001) for microbial load, metabolic activity and biofilm viability. CONCLUSIONS: It was concluded that the BvK, Ec and Ps dentifrices are useful for cleaning complete dentures, as they have antimicrobial activity against biofilm. The dentifrices containing Bowdichia virgilioides Kunth showed medium abrasiveness and should be used with caution.


Asunto(s)
Biopelículas , Dentífricos , Dentadura Completa , Ensayo de Materiales , Aceites Volátiles , Biopelículas/efectos de los fármacos , Dentífricos/farmacología , Dentífricos/química , Aceites Volátiles/farmacología , Aceites Volátiles/química , Dentadura Completa/microbiología , Factores de Tiempo , Reproducibilidad de los Resultados , Cepillado Dental , Recuento de Colonia Microbiana , Staphylococcus aureus/efectos de los fármacos , Estadísticas no Paramétricas , Streptococcus mutans/efectos de los fármacos , Análisis de Varianza , Viabilidad Microbiana/efectos de los fármacos , Candida albicans/efectos de los fármacos , Valores de Referencia , Resinas Acrílicas/química , Resinas Acrílicas/farmacología
4.
Pan Afr Med J ; 47: 105, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38766568

RESUMEN

Denture-induced fibrous hyperplasia (DIFH) is a persistent lesion caused by low-intensity chronic injury of the tissue in contact with an ill-fitting, over-extended denture. This fibrous connective tissue lesion commonly occurs in oral mucosa in patients showing important alveolar ridge atrophy. Surgical excision is the treatment of choice for DIFH. This article describes a successful laser surgery to remove a DIFH on a lower alveolar ridge of a patient wearing an ill-fitting completely removable denture. The use of a diode laser may result in less surgical time, less bleeding during surgery, more vestibular depth, better re-epithelialization of the wound, and no need for suturing.


Asunto(s)
Hiperplasia , Láseres de Semiconductores , Humanos , Láseres de Semiconductores/uso terapéutico , Hiperplasia/cirugía , Femenino , Mucosa Bucal/patología , Terapia por Láser/métodos , Terapia por Láser/efectos adversos , Fibrosis , Dentadura Completa , Persona de Mediana Edad
5.
Clin Oral Investig ; 28(6): 320, 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38750145

RESUMEN

OBJECTIVES: The purpose of this scoping review was to identify different methods employed for recording the maxillomandibular relationship (MMR) for computer-aided designed and manufactured (CAD-CAM) complete dentures (CDs). MATERIALS AND METHODS: This scoping review followed the PRISMA-ScR guidelines and was developed according to Arksey and O'Malley and The Joanna Briggs Institute protocol. The methods were registered on the Open Science Framework (< osf.io/rf4xm> ). The focus question was: "What are the different techniques for recording the maxillomandibular relationship in the digital workflow used in CECDs?" Two investigators searched 3 online databases [MEDLINE (PubMed), Scopus, and Science Direct] independently. The inclusion criteria were clinical studies and reviews that assessed techniques for recording MMR using digital workflow for manufacturing of CECDs. A descriptive analysis was performed considering the study design, manufacturing system, clinical steps, and tools for the determination of MMR, and the difficulty level of procedures. RESULTS: 4779 articles were identified in the electronic search and 10 studies were included for data analysis. The review identified 4 commercially available CAD-CAM denture systems and 3 innovative methods suitable for abbreviating the number of appointments (2 to 4 visits). The trial denture is inherent to the procedure for the Baltic System and 3 innovative techniques. Three techniques (2 innovative and WholeYouNexteeth) demonstrated lower difficulty levels for performing the clinical procedures, regardless of the professional skills. CONCLUSIONS: The commercially available and innovative techniques for the recording of MMR may provide predictability of the treatment. The techniques are effective, however, rely on the learning curve and the patient's clinical condition. CLINICAL RELEVANCE: Recording of the maxillomandibular relationship is paramount for the manufacturing and functionality of complete dentures. Clinicians should be aware of the different tools and techniques described for registering the jaw relationship.


Asunto(s)
Diseño Asistido por Computadora , Diseño de Dentadura , Dentadura Completa , Humanos , Diseño de Dentadura/métodos , Registro de la Relación Maxilomandibular/métodos
6.
Clin Oral Investig ; 28(5): 255, 2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38630185

RESUMEN

OBJECTIVES: To evaluate the trueness of the digital maxillary occlusal records in comparison with the conventional records for the fabrication of complete-arch implant-supported fixed prostheses. MATERIALS AND METHODS: This randomized controlled clinical trial followed the recommendations of the CONSORT statement. Twenty participants who used a mandibular interim complete-arch fixed prosthesis and conventional complete maxillary dentures were included in the study. The participants were randomized into two types of maxillary occlusal records: conventional (COR) and digital (DOR) (TRIOS; Shape A/S). After fabricating the prostheses, the distribution and number of occlusal contact points, and the time taken to obtain the maxillary occlusal record and work model were evaluated. Descriptive analysis was used to evaluate the distribution of occlusal contact points. The Wilcoxon test was employed for assessing the number of occlusal contact points, while the Mann-Whitney U test was used for the time taken to obtain the working casts and the maxillary occlusal record and occlusal adjustment times (p < 0.05). RESULTS: There was a similarity in the jaw relation recording methods regarding the distribution of occlusal contact points. There was no difference in the number of occlusal contact points between the anterior (p = 0.439) and posterior (p = 0.227) teeth. No relationship was observed between the distribution and number of occlusal contact points (COR, p = 0.288; DOR, p = 0.183). DOR required less occlusal and clinical adjustment time, on the other hand more laboratory and total workflow time than COR (p < 0.001). CONCLUSION: The DOR may be an option for obtaining the functional space necessary for the assembly of teeth in complete-arch implant-supported fixed prostheses; however, it requires more working time. CLINICAL RELEVANCE: The digital occlusal recording method can be used to assess the interocclusal space for the virtual tooth setup of a complete-arch implant-supported fixed prosthesis.


Asunto(s)
Implantes Dentales , Humanos , Dentadura Completa , Registro de la Relación Maxilomandibular , Laboratorios , Mandíbula
7.
J Hist Dent ; 72(1): 74-88, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38642384

RESUMEN

The modern theory of complete denture retention using suction was applied to wooden plate dentures in Japan from the first half of the 16th century, which is an astonishing achievement since it was clinically applied in North America and Europe in the latter half of the 19th century nearly 300 years later. Wooden dentures are unique to Japan resulting from skilled Japanese craftsmanship and are not found in other countries. We comprehensively reviewed reports on wooden plate dentures, analyzed 145 complete and partial dentures, and discussed their history. Japanese wooden plate dentures are mainly made of box wood, and artificial teeth are made of pagodite, ivory, and natural teeth. Small nails were driven into the molar region. Many existing dentures revealed attrition on the occlusal faces, thereby indicating that the wearers were able to masticate sufficiently. Wooden plate dentures have been used for 400 years in the early 20th century. Although Japanese wooden dentures have not been mentioned in the history of dentistry in Western literature, they comprise an important part of the history of denture development.


Asunto(s)
Dentadura Completa , Boca Edéntula , Humanos , Japón , Succión , Dentadura Parcial
8.
BMC Oral Health ; 24(1): 473, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38641783

RESUMEN

BACKGROUND: The establishment of good facial esthetics is one of the main objectives of complete denture construction. Unfortunately, it may be the caused issue for patients having a prominent premaxilla due to excessive lip support by the labial flange of the maxillary denture. Open-face dentures (OFD) may suggest suitable prosthetic management for these patients. However, clinical evidence regarding the efficiency of OFD is scarce. METHODS: A total of 38 completely edentulous participants having prominent premaxilla and skeletal class I Angle's classification were enrolled in this study. Each participant received a mandibular complete denture and 2 opposing maxillary dentures; conventional (CD) and open-face (OFD). On the day of denture insertion, the participants were divided into 2 groups; CD-OFD and OFD-CD where CD-OFD group was instructed to use the mandibular denture and the maxillary CD for 3 months and then to use the maxillary OFD for another 3 months after a wash-out period of 2 weeks. While group OFD-CD was instructed to use the mandibular denture and the maxillary OFD for 3 months then to use the maxillary CD for another 3 months after a wash-out period of 2 weeks. The dislodging force of the maxillary dentures was evaluated using the universal testing machine and the patient perception of retention, esthetics, and comfort was evaluated using the Visual Analogue Scale (VAS). Evaluation was carried out 1 day, 1 month, and 3 months after denture insertion. The Student t-test was used to compare the 2 maxillary dentures and the intervals for each denture were compared by using the ANOVA test with repeated measures followed by a Post Hoc test (adjusted Bonferroni) for pairwise comparison. RESULTS: The significance of the obtained results was judged at the 5% level (P value). The dislodging force and patient perception of retention did not show significant differences between the 2 dentures, while the perception of esthetics showed significant differences throughout the follow-up period. Perception of comfort showed an insignificant difference only at the 3-month interval. CONCLUSIONS: Open-face maxillary dentures can be a suitable alternative for patients with prominent premaxilla to achieve satisfactory retention, aesthetics, and comfort.


Asunto(s)
Dentadura Completa Superior , Boca Edéntula , Humanos , Estudios Cruzados , Diseño de Dentadura/métodos , Dentadura Completa , Retención de Dentadura , Satisfacción del Paciente
9.
Sci Rep ; 14(1): 9559, 2024 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-38671220

RESUMEN

This study aims to examine the relationship between the locations of Fovea Palatinae and the posterior vibrating line in different classes of soft palate angulation (House Classification), accordingly determine its reliability as a landmark and a tool for determining the posterior limit of the maxillary complete denture. 280 completely edentulous patients with normal healthy mucosa from both genders were randomly selected. The House classification of the soft palate angulation was identified and recorded as Class I, II, or III. Phonation was used to determine the position of the vibrating line. The Fovea Palatinae was then marked. Then, the distance between the Fovea Palatinae and the vibrating line was measured and recorded. Finally, the relative position of the Fovea Palatinae to the vibrating line was recorded as being anterior, posterior, or on the vibrating line. The Chi Square test, the effect size measures (Eta and Cramer's V tests), The Spearman's Rho rank correlation test, and multinominal logistic regression analysis were utilized to analyse the data. House classification percentages were measured among people whose Fovea Palatinae was detectable; Class II palate was the most prevalent (47.14%), followed by Class I (43.93%), and then Class III (8.93%). Based on vibrating line position, 129 (58%) had a vibrating line anterior to Fovea Palatinae, 57 (26%) on the Fovea Palatinae, 36 (16%) posterior to Fovea Palatinae, and in 58 (21%) Fovea Palatinae were not detected. The mean distance between the vibrating line and Fovea Palatinae was 3.66 ± 1.6 mm anteriorly and 2.97 ± 1.36 mm posteriorly. No significant differences were found between males and females in regard to House classification and vibrating line position. The odds of having the fovea posterior to the vibrating line would increase by 5% for each year increase in the age (P = 0.035, odds ratio = 1.050). Class II House classification of the soft palate was found to be the most prevalent among the study participants. Also, the vibrating line was anterior to the Fovea Palatinae in the majority of cases. The odds of having the fovea posterior to the vibrating line would increase by age. The Fovea Palatinae could be considered a useful guide for locating the vibrating line.


Asunto(s)
Paladar Blando , Humanos , Femenino , Masculino , Persona de Mediana Edad , Paladar Blando/anatomía & histología , Anciano , Jordania , Boca Edéntula/epidemiología , Adulto , Vibración , Dentadura Completa
10.
J Appl Oral Sci ; 32: e20230326, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38656049

RESUMEN

OBJECTIVE: This study evaluated the surface roughness, wettability and adhesion of multispecies biofilms (Candida albicans, Staphylococcus aureus and Streptococcus mutans) on 3D-printed resins for complete denture bases and teeth compared to conventional resins (heat-polymerized acrylic resin; artificial pre-fabricated teeth). METHODOLOGY: Circular specimens (n=39; 6.0 mm Ø × 2.0 mm) of each group were subjected to roughness (n=30), wettability (n=30) and biofilm adhesion (n=9) tests. Three roughness measurements were taken by laser confocal microscopy and a mean value was calculated. Wettability was evaluated by the contact angle of sessile drop method, considering the mean of the three evaluations per specimen. In parallel, microorganism adhesion to resin surfaces was evaluated using a multispecies biofilm model. Microbial load was evaluated by determining the number of Colony Forming Units (CFU/mL) and by scanning electron microscopy (SEM). Data were subjected to the Wald test in a generalized linear model with multiple comparisons and Bonferroni adjustment, as well as two-way ANOVA (α=5%). RESULTS: The roughness of the conventional base resin (0.01±0.04) was lower than that of the conventional tooth (0.14±0.04) (p=0.023) and 3D-printed base (0.18±0.08) (p<0.001). For wettability, conventional resin (84.20±5.57) showed a higher contact angle than the 3D-printed resin (60.58±6.18) (p<0.001). Higher microbial loads of S. mutans (p=0.023) and S. aureus (p=0.010) were observed on the surface of the conventional resin (S. mutans: 5.48±1.55; S. aureus: 7.01±0.57) compared to the 3D-printed resin (S. mutans: 4.11±1.96; S. aureus: 6.42±0.78). The adhesion of C. albicans was not affected by surface characteristics. The conventional base resin showed less roughness than the conventional dental resin and the printed base resin. CONCLUSION: The 3D-printed resins for base and tooth showed less hydrophobicity and less adhesion of S. mutans and S. aureus than conventional resins.


Asunto(s)
Resinas Acrílicas , Adhesión Bacteriana , Biopelículas , Candida albicans , Bases para Dentadura , Ensayo de Materiales , Microscopía Confocal , Microscopía Electrónica de Rastreo , Impresión Tridimensional , Staphylococcus aureus , Streptococcus mutans , Propiedades de Superficie , Humectabilidad , Streptococcus mutans/fisiología , Staphylococcus aureus/fisiología , Candida albicans/fisiología , Bases para Dentadura/microbiología , Resinas Acrílicas/química , Análisis de Varianza , Reproducibilidad de los Resultados , Dentadura Completa/microbiología , Valores de Referencia , Recuento de Colonia Microbiana , Modelos Lineales
11.
Int J Prosthodont ; 37(2): 210-220, 2024 04 22.
Artículo en Inglés | MEDLINE | ID: mdl-38648166

RESUMEN

PURPOSE: To evaluate whether complete dentures (CDs) relined with long-term resilient liners (LTRLs) favor better masticatory function, satisfaction, and quality of life among completely edentulous patients compared to conventional CDs. MATERIALS AND METHODS: This review followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) checklist and was registered in PROSPERO (the International Prospective Register of Systematic Reviews; CRD42021258700). The population, intervention, comparison, and outcome (PICO) purpose was to determine whether CDs relined with LTRLs favor better masticatory function, satisfaction, and quality of life among completely edentulous patients when compared to CDs. Searches were performed in the PubMed/MEDLINE, Embase, Scopus, Lilacs, BBO, and OpenGrey databases. Manual searches were also performed to identify additional primary studies. RESULTS: Overall, 3,953 articles were found. After removing duplicates, reading the articles, and applying the inclusion and exclusion criteria, 15 articles were selected for qualitative analysis, totaling 422 patients with follow-up periods ranging from 1 week to 3 years. Among these, 8 studies assessed masticatory function using different methods, 2 assessed satisfaction, 1 assessed quality of life, and 4 assessed more than one outcome. Through qualitative analysis, LTRLs showed satisfactory results in most studies when compared to CDs in relation to masticatory function, satisfaction, and quality of life. CONCLUSIONS: LTRLs favor better masticatory function, satisfaction, and quality of life among completely edentulous patients compared to CDs.


Asunto(s)
Dentadura Completa , Masticación , Satisfacción del Paciente , Calidad de Vida , Humanos , Masticación/fisiología , Alineadores Dentales , Rebasado de Dentaduras , Boca Edéntula/rehabilitación , Boca Edéntula/psicología
12.
J Appl Oral Sci ; 32: e20230381, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38537031

RESUMEN

BACKGROUND: Denture biofilm acts as a potential reservoir for respiratory pathogens, considerably increasing the risk of lung infections, specifically aspiration pneumonia, mainly 48h after hospital admission. The establishment of a straightforward, affordable, and applicable hygiene protocol in a hospital environment for the effective control of denture biofilm can be particularly useful to prevent respiratory infections or reduce the course of established lung disease. OBJECTIVES: To evaluate the anti-biofilm effectiveness of denture cleaning protocols in hospitalized patients. METHODOLOGY: The maxillary complete dentures (MCDs) of 340 hospitalized participants were randomly cleaned once using one of the following 17 protocols (n=20): brushing with distilled water, toothpaste, or neutral liquid soap (controls); immersion in chemical solutions (1% sodium hypochlorite, alkaline peroxide, 0.12% or 2% chlorhexidine digluconate), or microwave irradiation (650 W for 3 min) combined or not with brushing. Before and after the application of the protocols, the biofilm of the intaglio surface of the MCDs was evaluated using two methods: denture biofilm coverage area (%) and microbiological quantitative cultures on blood agar and Sabouraud Dextrose Agar (CFU/mL). Data were subjected to the Wilcoxon and Kruskal-Wallis tests (α=0.05). RESULTS: All 17 protocols significantly reduced the percentage area of denture biofilm and microbial and fungal load (P<0.05). The highest percentage reductions in the area of denture biofilm were observed for 1% hypochlorite solution with or without brushing and for 2% chlorhexidine solution and microwave irradiation only in association with brushing (P<0.05). The greatest reductions in microbial and fungal load were found for the groups that used solutions of 2% chlorhexidine and 1% hypochlorite and microwave irradiation, regardless of the association with brushing (P<0.05). CONCLUSIONS: A single immersion for 10 min in 1% sodium hypochlorite, even in the absence of brushing, proved to be a straightforward, rapid, low-cost, and effective protocol for cleaning the dentures of hospitalized patients.


Asunto(s)
Clorhexidina , Hipoclorito de Sodio , Humanos , Agar/farmacología , Biopelículas , Clorhexidina/farmacología , Limpiadores de Dentadura/farmacología , Dentadura Completa/microbiología , Dentaduras/microbiología , Ácido Hipocloroso/farmacología , Hipoclorito de Sodio/farmacología
13.
BMC Oral Health ; 24(1): 405, 2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38555452

RESUMEN

OBJECTIVE: To assess stress distribution in peri-implant bone and attachments of mandibular overdentures retained by small diameter implants, and to explore the impact of implant distribution on denture stability. METHODS: Through three-dimensional Finite Element Analysis (3D FEA), four models were established: three models of a two mandibular implants retained overdenture (IOD) and one model of a conventional complete denture (CD). The three IOD models consisted of one with two implants in the bilateral canine area, another with implants in the bilateral lateral incisor area, and the third with one implant in the canine area, and another in the lateral incisor area. Three types of loads were applied on the overdenture for each model: a 100 N vertical load and a inclined load on the left first molar, and a100N vertical load on the lower incisors. The stress distribution in the peri-implant bone, attachments, and the biomechanical behaviors of the overdentures were analyzed. RESULTS: Despite different distribution of implants, the maximum stress values in peri-implant bone remained within the physiological threshold for all models across three loading conditions. The dispersed implant distribution design (implant in the canine area) exhibited the highest maximum stress in peri-implant bone (822.8 µe) and the attachments (275 MPa) among the three IOD models. The CD model demonstrated highest peak pressure on mucosa under three loading conditions (0.8188 Mpa). The contact area between the denture and mucosa of the CD model was smaller than that in the IOD models under molar loading, yet it was larger in the CD model compared to the IOD model under anterior loading. However, the contact area between the denture and mucosa under anterior loading in all models was significantly smaller than those under molar loading. The IOD in all three models exhibited significantly less rotational movement than the complete denture. Different implant positions had minimal impact on the rotational movement of the IOD. CONCLUSION: IOD with implants in canine area exhibited the highest maximum stress in the peri-implant bone and attachments, and demonstrated increased rotational movement. The maximum principal stress was concentrated around the neck of the small diameter one-piece implant, rather than in the abutment. An overdenture retained by two implants showed better stability than a complete denture.


Asunto(s)
Implantes Dentales , Humanos , Prótesis de Recubrimiento , Análisis de Elementos Finitos , Dentadura Completa , Mandíbula , Prótesis Dental de Soporte Implantado , Análisis del Estrés Dental/métodos , Retención de Dentadura
14.
Int J Oral Maxillofac Implants ; 39(1): 127-134, 2024 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-38416006

RESUMEN

PURPOSE: To evaluate the precision and efficiency of a novel guide system for single implant placement in the mandibular symphyses and to evaluate whether the outcome is affected by the level of operator experience. MATERIALS AND METHODS: A total of 90 implants were placed in three different mandibular cast types (Cawood and Howell class III, IV, and V). For each model, a complete denture was 3D printed. A polyether ether ketone rail with a guide sleeve was embedded in the middle of the denture. To determine the ideal implant position, the sleeve could be moved in a buccolingual direction. Adjustment of implant angulation was possible, and an angle correction of 0, 12, or 24 degrees was available. A total of 30 clinicians were divided into three groups: group 1 (experienced, n = 10), group 2 (beginner, n = 10), and group 3 (inexperienced, n = 10). Each clinician was asked to plan and perform a guided flapless implant placement in the mandibular symphysis. Two preoperative CBCT scans were taken; the first was to verify the planning, and the second was to adjust the planning if needed. Finally, a postoperative CBCT scan was taken to compare the planning to the final implant position. RESULTS: Based on the first CBCT, the clinicians adjusted their planning by an average of 1.66 ± 1.65 mm coronally, 2.41 ± 2.44 mm apically, and by a mean angular correction of 6.08 ± 0.77 degrees. After implant placement, the mean deviation from the planned implant position was 0.87 ± 0.58 mm at the coronal aspect and 0.98 ± 0.64 mm at the apical aspect. The mean angular deviation was 6.05 ± 0.71 degrees. Overall, there were no significant differences in coronal and apical deviation (P > .05) based on the level of experience. In terms of angulation, a significant difference was found in both planning (P = .049) and placement (P = .038) between beginners and experienced clinicians. CONCLUSIONS: Guided implant placement of a single implant in the mandibular symphysis using a removable denture with guide sleeve had an acceptable level of accuracy. Clinicians with limited experience spent more time on the procedure, resulting in less angular deviation during implant planning and placement compared to experienced clinicians.


Asunto(s)
Implantes Dentales , Prótesis de Recubrimiento , Proyectos de Investigación , Dentadura Completa , Mandíbula/cirugía
15.
Medicina (Kaunas) ; 60(2)2024 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-38399547

RESUMEN

With the life expectancy increasing, there is a growing need for prosthetic dental treatments to restore the oral health, function, and quality of life of edentulous patients. Presently, only a few articles are available describing the oral rehabilitation of patients with severely resorbed ridges with milled complete dentures. This clinical case report provides a straightforward protocol consisting of a combination of analog and digital techniques for the rehabilitation of edentulous patients with severely resorbed ridges with milled fixed and removable complete dentures. This technique permits the minimization of the number of appointments, improves patient comfort, allows for the digital archiving of important clinical data, and permits the manufacture of prostheses with improved mechanical properties. These favorable outcomes were achieved by using the patient's existing PMMA complete denture as a custom tray for a final impression with light-bodied Polyvinylsiloxane. Subsequently, the resulting models were digitized, and a digital complete denture was designed and manufactured in an expedited manner using CAD-CAM techniques. Therefore, this case report highlights the potential of CAD/CAM technology to predictably restabilize oral functions and improve patients' quality of life.


Asunto(s)
Boca Edéntula , Calidad de Vida , Humanos , Dentadura Completa , Boca Edéntula/rehabilitación , Diseño Asistido por Computadora
16.
Br Dent J ; 236(3): 213, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38332095
17.
Clin Exp Dent Res ; 10(1): e829, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38345518

RESUMEN

OBJECTIVES: Patient perception and satisfaction with dentures are important indicators in prosthodontic treatment. This study aimed to compare patients' satisfaction with VertexThermosens dentures versus conventional acrylic dentures during a 12-month study period. MATERIAL AND METHODS: This randomized study involved 60 participants aged between 45 and 80 with representation of both sexes. The patients were divided into two groups: The first group (experimental group), which had complete dentures from VertexThermosens base material included 30 participants. The second group (control group), which had complete dentures from convectional rigid acrylic base material, included 30 participants. Patient satisfaction with the dentures was assessed in each of the two Vertex/Acrylic groups through a specially created questionnaire of five questions with a five-point Likert scale of possible answers (0 = never; 1 = rarely; 2 = occasionally; 3 = often; and 4 = very often). RESULTS: After 12 months, intergroup comparison with Mann-Whitney U Test related to Q2 (p = 0.193), Q3 (p = 0.960), Q4 (p = 0.317), Q5 (p = 1.000) patient satisfactions indicated that there was no significant difference between the two groups (Vertex/Acrylic), except  Q1 (p = 0.010) question, Vertex group was more satisfied. The results regarding the patients of both groups (Vertex/Acrylic) showed that after 12 months of wearing the denture, the satisfaction level regarding to all questions increased, except Q5-question for Vertex group, where the difference was not significant due to the already achieved maximum satisfaction at zero time. CONCLUSION: Based on the findings of this clinical study, it can be concluded that higher satisfaction is seen in patients rehabilitated with VertexThermosens dentures than with conventional rigid acrylic dentures.


Asunto(s)
Dentadura Completa , Satisfacción del Paciente , Masculino , Femenino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años
18.
J Prosthet Dent ; 131(4): 706.e1-706.e8, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38310062

RESUMEN

STATEMENT OF PROBLEM: Technological advances in digital acquisition tools have increased the scope of intraoral scanners (IOSs), including scanning a removable complete denture (RCD) to replicate it. However, studies assessing the accuracy of IOSs for replicating a maxillary or mandibular RCD are lacking. PURPOSE: The purpose of this in vitro study was to evaluate the accuracy (trueness and precision) of 3 IOSs while replicating a maxillary and mandibular RCD. MATERIAL AND METHODS: One maxillary and 1 mandibular RCD were scanned with a desktop scanner (D2000) to obtain the reference model. Two operators scanned each RCD 5 times with 3 different IOSs (TRIOS 4, Primescan, and IS3800), following a predefined acquisition protocol. The 60 study models obtained were compared with the reference model using the Geomagic software program. For each comparison, the mean and standard deviation of discrepancy were calculated. Distances were measured on both the reference and the study model, and differences were calculated to assess whether sagittal or transverse deformations were present. The tolerance percentage of the volume of the digital model compared with the volume of the reference model was determined (difference tolerance was set at 0.1 mm). A univariate analysis of variance followed by a post hoc analysis using the Student-Newman-Keuls (α=.05) test was performed to determine the truest and the most precise IOS. RESULTS: The TRIOS 4 and Primescan IOSs had comparable trueness, with mean dimensional variations of 47 ±27 µm and 57 ±8 µm respectively compared with the reference model. The IS3800 had a lower trueness (98 ±35 µm). Primescan was significantly more precise with a mean standard deviation of 64 ±15 µm (P<.05). The TRIOS 4 (141 ±48 µm) and IS3800 (129 ±24 µm) had comparable precision. Primescan showed the least sagittal and transverse deformation. CONCLUSIONS: This study determined that an RCD can be replicated using an IOS, although all IOSs did not have equal accuracy. An in vivo study needs to assess whether this procedure is clinically acceptable.


Asunto(s)
Diseño Asistido por Computadora , Imagenología Tridimensional , Humanos , Técnica de Impresión Dental , Modelos Dentales , Arco Dental , Dentadura Completa
19.
J Oral Rehabil ; 51(6): 931-937, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38356185

RESUMEN

BACKGROUND: Denture-induced oral Lesions (DIOLs) often manifests shortly after the placement or adjustment of new or realigned dentures, frequently resulting in severe pain and discomfort. OBJECTIVES: This study aimed to classify DIOLs placing a particular emphasis on assessing the associated pain. METHODS: A prospective case study was conducted involving 126 patients who were fitted with a total of 193 dentures of various types at the Hadassah School of Dental Medicine. All patients underwent comprehensive intra-oral examinations within 1-8 weeks following denture delivery, completed symptom questionnaires and had their medical records reviewed. Key variables documented included age, gender, overall health status, denture type, and a detailed description of the DIOLs. The description encompassed factors such as lesion location, shape, colour, size, border characteristics, ulcerative appearance, membrane coverage, 3D morphology (elevated, immersed and flat) and patient-reported Verbal Pain Score (VPS) when touching the DIOLs, when wearing the denture, and when not wearing the denture. RESULTS: Notably, 25.4% of denture wearers required no adjustments, while 14.4% necessitated more than three revisions. A majority (71.8%) of DIOLs cases were associated with mandibular complete dentures, primarily situated on the alveolar ridge. The mean VPS indicated a pain intensity of 7 ± 2.1, with temporary dentures in both jaws causing the most discomfort. Implant-supported overdentures were particularly painful when placed in the mandible. Additionally, VPS scores were higher among older individuals and those with prior prosthetic experiences. A significant correlation was observed between pain intensity and presence of chronic health condition (0.036). CONCLUSIONS: This study revealed distinct characteristics of DIOLs and highlighted the multifactorial nature of pain experienced following the development of DIOLs. Insights into the influence of patient and denture characteristics on DIOLs and pain intensity can guide healthcare professionals in optimising patient comfort and satisfaction.


Asunto(s)
Dimensión del Dolor , Humanos , Femenino , Masculino , Estudios Prospectivos , Anciano , Persona de Mediana Edad , Anciano de 80 o más Años , Dentadura Completa/efectos adversos , Dentaduras/efectos adversos , Estomatitis Subprotética/etiología , Adulto
20.
Gerodontology ; 41(2): 305-309, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38422399

RESUMEN

OBJECTIVE: To describe the clinical procedures of complete denture set fabrication in three appointments. BACKGROUND: Simplified approaches have proven not to be inferior to conventional ones in terms of quality, patient satisfaction and masticatory ability. MATERIALS AND METHODS: The patient was a 77-year-old edentulous adult with mobility impairment seeking dental rehabilitation in a small number of appointments due to commuting difficulties. RESULTS: A set of complete dentures was delivered within three appointments. The second appointment was dedicated to set-up trial due to the patient's aesthetic demands. CONCLUSION: Under certain circumstances and after a thorough study of each case, dental clinicians may propose the fabrication of complete dentures in a three-appointment protocol incorporating a set-up trial session.


Asunto(s)
Diseño de Dentadura , Dentadura Completa , Humanos , Anciano , Boca Edéntula/rehabilitación , Limitación de la Movilidad , Masculino , Femenino , Citas y Horarios , Técnica de Impresión Dental
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...