1.
Appl Radiat Isot ; 127: 237-244, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28651206

RESUMEN

This study evaluates the role of defects on the performances of synthetic diamond sensors on exposure to mammography X-rays. Through systematic investigations, the main cause of instability of response of examined sensors necessitating pre-irradiation was isolated and ascribed to the presence of ambient light which has the effect of emptying shallow trapping levels. The changes in response between measurements in light and dark conditions varied from 2.8 ± 1.2% to 63.0 ± 0.3%. Sensitivities between 0.4 and 6.7nCGy-1mm-3 determined for the sensors varied with defect levels. The study indicates that differences in crystal quality due to the presence and influence of defects would cause a discrepancy in the dosimetric performances of various diamond detectors. Once a sensor plate is selected (based on the influence of defect levels) and coupled to the probe housing with the response of the diamond sensor stabilised and appropriately shielded from ambient light, daily priming is not needed.


Asunto(s)
Diamante , Mamografía , Radiometría/instrumentación , Diamante/química , Diamante/efectos de la radiación , Diamante/normas , Espectroscopía de Resonancia por Spin del Electrón , Femenino , Humanos , Mamografía/estadística & datos numéricos , Dosis de Radiación , Radiometría/estadística & datos numéricos , Espectroscopía Infrarroja por Transformada de Fourier , Espectrometría Raman , Dosimetría Termoluminiscente
2.
Sci Rep ; 7(1): 385, 2017 03 24.
Artículo en Inglés | MEDLINE | ID: mdl-28341859

RESUMEN

Ion irradiation is a widely employed tool to fabricate diamond micro- and nano-structures for applications in integrated photonics and quantum optics. In this context, it is essential to accurately assess the effect of ion-induced damage on the variation of the refractive index of the material, both to control the side effects in the fabrication process and possibly finely tune such variations. Several partially contradictory accounts have been provided on the effect of the ion irradiation on the refractive index of single crystal diamond. These discrepancies may be attributable to the fact that in all cases the ions are implanted in the bulk of the material, thus inducing a series of concurrent effects (volume expansion, stress, doping, etc.). Here we report the systematic characterization of the refractive index variations occurring in a 38 µm thin artificial diamond sample upon irradiation with high-energy (3 MeV and 5 MeV) protons. In this configuration the ions are fully transmitted through the sample, while inducing an almost uniform damage profile with depth. Therefore, our findings conclusively identify and accurately quantify the change in the material polarizability as a function of ion beam damage as the primary cause for the modification of its refractive index.


Asunto(s)
Diamante/química , Diamante/efectos de la radiación , Fenómenos Ópticos , Óptica y Fotónica , Protones , Refractometría
3.
Appl Radiat Isot ; 126: 66-72, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28161102

RESUMEN

Treated green diamonds can show residual radioactivity, generally due to immersion in radium salts. We report various activity measurements on two radioactive diamonds. The activity was characterized by alpha and gamma ray spectrometry, and the radon emanation was measured by alpha counting of a frozen source. Even when no residual radium contamination can be identified, measurable alpha and high-energy beta emissions could be detected. The potential health impact of radioactive diamonds and their status with regard to the regulatory policy for radioactive products are discussed.


Asunto(s)
Diamante/química , Diamante/efectos de la radiación , Joyas/análisis , Joyas/efectos de la radiación , Partículas alfa , Partículas beta , Bismuto/análisis , Color , Rayos gamma , Humanos , Joyas/efectos adversos , Polonio/análisis , Radiactividad , Radioisótopos/análisis , Radiometría , Radio (Elemento)/análisis , Radón/análisis , Espectrometría gamma , Propiedades de Superficie
4.
Phys Med Biol ; 61(17): 6413-29, 2016 09 07.
Artículo en Inglés | MEDLINE | ID: mdl-27499356

RESUMEN

Small diamond detectors are useful for the dosimetry of high-energy proton beams. However, linear energy transfer (LET) dependence has been observed in the literature with such solid state detectors. A novel synthetic diamond detector has recently become commercially available from the manufacturer PTW-Freiburg (PTW microDiamond type 60019). This study was designed to thoroughly characterize four microDiamond detectors in clinical proton beams, in order to investigate their response and their reproducibility in high LET regions. Very good dosimetric characteristics were observed for two of them, with good stability of their response (deviation less than 0.4% after a pre-irradiation dose of approximately 12 Gy), good repeatability (coefficient of variation of 0.06%) and a sensitivity of approximately 0.85 nC Gy(-1). A negligible dose rate dependence was also observed for these two microDiamonds with a deviation of the sensitivity less than 0.7% with respect to the one measured at the reference dose rate of 2.17 Gy min(-1), in the investigated dose rate range from 1.01 Gy min(-1) to 5.52 Gy min(-1). Lateral dose profile measurements showed the high spatial resolution of the microDiamond oriented with its stem perpendicular to the beam axis and with its small sensitive thickness of about 1 µm in the scanning profile direction. Finally, no significant LET dependence was found with these two diamond dosimeters in comparison to a reference ionization chamber (model IBA PPC05). These good results were in accordance to the literature. However, this study showed also a non reproducibility between the devices in terms of stability, sensitivity and LET dependence, since the two other microDiamonds characterized in this work showed different dosimetric characteristics making them not suitable for proton beam dosimetry with a maximum difference of the peak-to-plateau ratio of 6.7% relative to the reference ionization chamber in a clinical 138 MeV proton beam.


Asunto(s)
Terapia de Protones/métodos , Dosímetros de Radiación/normas , Diamante/química , Diamante/efectos de la radiación , Transferencia Lineal de Energía , Terapia de Protones/instrumentación , Terapia de Protones/normas , Radiometría/instrumentación , Radiometría/métodos
5.
Z Med Phys ; 26(1): 88-94, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26323984

RESUMEN

In this work, the performance of a microDiamond detector in a scanned proton beam is studied and its potential role in the dosimetric characterization of proton pencil beams is assessed. The linearity of the detector response with the absorbed dose and the dependence on the dose-rate were tested. The depth-dose curve and the lateral dose profiles of a proton pencil beam were measured and compared to reference data. The feasibility of calibrating the beam monitor chamber with a microDiamond detector was also studied. It was found the detector reading is linear with the absorbed dose to water (down to few cGy) and the detector response is independent of both the dose-rate (up to few Gy/s) and the proton beam energy (within the whole clinically-relevant energy range). The detector showed a good performance in depth-dose curve and lateral dose profile measurements; and it might even be used to calibrate the beam monitor chambers-provided it is cross-calibrated against a reference ionization chamber. In conclusion, the microDiamond detector was proved capable of performing an accurate dosimetric characterization of proton pencil beams.


Asunto(s)
Diamante/efectos de la radiación , Terapia de Protones/métodos , Radiometría/instrumentación , Relación Dosis-Respuesta en la Radiación , Diseño de Equipo , Análisis de Falla de Equipo , Dosificación Radioterapéutica , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
J Synchrotron Radiat ; 22(6): 1396-402, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26524304

RESUMEN

Fabrication and testing of a prototype transmission-mode pixelated diamond X-ray detector (pitch size 60-100 µm), designed to simultaneously measure the flux, position and morphology of an X-ray beam in real time, are described. The pixel density is achieved by lithographically patterning vertical stripes on the front and horizontal stripes on the back of an electronic-grade chemical vapor deposition single-crystal diamond. The bias is rotated through the back horizontal stripes and the current is read out on the front vertical stripes at a rate of ∼ 1 kHz, which leads to an image sampling rate of ∼ 30 Hz. This novel signal readout scheme was tested at beamline X28C at the National Synchrotron Light Source (white beam, 5-15 keV) and at beamline G3 at the Cornell High Energy Synchrotron Source (monochromatic beam, 11.3 keV) with incident beam flux ranges from 1.8 × 10(-2) to 90 W mm(-2). Test results show that the novel detector provides precise beam position (positional noise within 1%) and morphology information (error within 2%), with an additional software-controlled single channel mode providing accurate flux measurement (fluctuation within 1%).


Asunto(s)
Diamante/química , Diamante/efectos de la radiación , Radiometría/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Transductores , Difracción de Rayos X/instrumentación , Relación Dosis-Respuesta en la Radiación , Diseño de Equipo , Análisis de Falla de Equipo , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
7.
Sensors (Basel) ; 13(10): 13744-78, 2013 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-24152932

RESUMEN

Amorphous-selenium (a-Se) based photodetectors are promising candidates for imaging devices, due to their high spatial resolution and response speed, as well as extremely high sensitivity enhanced by an internal carrier multiplication. In addition, a-Se is reported to show sensitivity against wide variety of wavelengths, including visible, UV and X-ray, where a-Se based flat-panel X-ray detector was proposed. In order to develop an ultra high-sensitivity photodetector with a wide detectable wavelength range, a photodetector was fabricated using a-Se photoconductor and a nitrogen-doped diamond cold cathode. In the study, a prototype photodetector has been developed, and its response to visible and ultraviolet light are characterized.


Asunto(s)
Diamante/química , Electrodos , Fotometría/instrumentación , Selenio/química , Transductores , Diamante/efectos de la radiación , Diseño de Equipo , Análisis de Falla de Equipo , Luz , Selenio/efectos de la radiación , Temperatura
8.
Opt Express ; 21(10): 12843-8, 2013 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-23736503

RESUMEN

We report on a novel method to fabricate single, multiple and large-area high-density ensembles of nitrogen vacancy (NV) color centers in synthetic type Ib bulk diamond by femtosecond laser illumination. Electron beams generated in propagation of intense infrared laser pulses in air sputtered on a diamond sample under high temperature aroused by the laser illumination, creating NV color centers. Typical photoluminescence (PL) spectra of NV centers could be observed on the illuminated spots. Photon streams from individual photoluminescent points exhibited anti-bunching effect by the second-order correlation measurement, evidencing single and multiple photon-emitters around the laser illuminated spots.


Asunto(s)
Diamante/química , Diamante/efectos de la radiación , Rayos Láser , Iluminación/instrumentación , Iluminación/métodos , Nitrógeno/química , Nitrógeno/efectos de la radiación , Color , Ensayo de Materiales , Fotones
9.
Opt Express ; 21(7): 8051-61, 2013 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-23571895

RESUMEN

Focusing hard x-ray free-electron laser radiation with extremely high fluence sets stringent demands on the x-ray optics. Any material placed in an intense x-ray beam is at risk of being damaged. Therefore, it is crucial to find the damage thresholds for focusing optics. In this paper we report experimental results of exposing tungsten and diamond diffractive optics to a prefocused 8.2 keV free-electron laser beam in order to find damage threshold fluence levels. Tungsten nanostructures were damaged at fluence levels above 500 mJ/cm(2). The damage was of mechanical character, caused by thermal stress variations. Diamond nanostructures were affected at a fluence of 59 000 mJ/cm(2). For fluence levels above this, a significant graphitization process was initiated. Scanning Electron Microscopy (SEM) and µ-Raman analysis were used to analyze exposed nanostructures.


Asunto(s)
Diamante/química , Diamante/efectos de la radiación , Rayos Láser , Lentes , Refractometría/instrumentación , Tungsteno/química , Tungsteno/efectos de la radiación , Diseño de Equipo , Análisis de Falla de Equipo , Dosis de Radiación , Rayos X
10.
Opt Express ; 20(17): 19382-94, 2012 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-23038581

RESUMEN

An accurate control of the optical properties of single crystal diamond during microfabrication processes such as ion implantation plays a crucial role in the engineering of integrated photonic devices. In this work we present a systematic study of the variation of both real and imaginary parts of the refractive index of single crystal diamond, when damaged with 2 and 3 MeV protons at low-medium fluences (range: 10(15) - 10(17) cm(-2)). After implanting in 125 × 125 µm(2) areas with a scanning ion microbeam, the variation of optical pathlength of the implanted regions was measured with laser interferometric microscopy, while their optical transmission was studied using a spectrometric set-up with micrometric spatial resolution. On the basis of a model taking into account the strongly non-uniform damage profile in the bulk sample, the variation of the complex refractive index as a function of damage density was evaluated.


Asunto(s)
Diamante/química , Diamante/efectos de la radiación , Modelos Químicos , Refractometría/métodos , Simulación por Computador , Luz , Protones , Dispersión de Radiación
11.
Med Phys ; 39(7): 4493-501, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22830781

RESUMEN

PURPOSE: To determine the potentialities of synthetic single crystal diamond Schottky diodes for accurate dose measurements in radiation therapy small photon beams. METHODS: The dosimetric properties of a diamond-based detector were assessed by comparison with a reference microionization chamber. The diamond device was operated at zero bias voltage under irradiation with high-energy radiotherapic photon beams. The stability of the detector response and its dose and dose rate dependence were measured. Different square field sizes ranging from 1 × 1 cm(2) to 10 × 10 cm(2) were used during comparative dose distribution measurements by means of percentage depth dose curves (PDDs), lateral beam profiles, and output factors. The angular and temperature dependence of the diamond detector response were also studied. RESULTS: The detector response shows a deviation from linearity of less than ±0.5% in the 0.01-7 Gy range and dose rate dependence below ±0.5% in the 1-6 Gy∕min range. PDDs and output factors are in good agreement with those measured by the reference ionization chamber within 1%. No angular dependence is observed by rotating the detector along its axis, while ∼3.5% maximum difference is measured by varying the radiation incidence angle in the polar direction. The temperature dependence was investigated as well and a ±0.2% variation of the detector response is found in the 18-40 °C range. CONCLUSIONS: The obtained results indicate the investigated synthetic diamond-based detector as a candidate for small field clinical radiation dosimetry in advanced radiation therapy techniques.


Asunto(s)
Diamante/química , Diamante/efectos de la radiación , Radiometría/instrumentación , Cristalización , Diseño de Equipo , Análisis de Falla de Equipo , Ensayo de Materiales , Fotones/uso terapéutico , Dosis de Radiación , Radiometría/métodos
12.
J Phys Condens Matter ; 24(27): 275801, 2012 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-22713291

RESUMEN

A real-time and real-space time-dependent density functional is applied to simulate the nonlinear electron-photon interactions during shaped femtosecond laser pulse train ablation of diamond. Effects of the key pulse train parameters such as the pulse separation, spatial/temporal pulse energy distribution and pulse number per train on the electron excitation and energy absorption are discussed. The calculations show that photon-electron interactions and transient localized electron dynamics can be controlled including photon absorption, electron excitation, electron density, and free electron distribution by the ultrafast laser pulse train.


Asunto(s)
Diamante/química , Diamante/efectos de la radiación , Electrones , Rayos Láser , Simulación de Dinámica Molecular , Teoría Cuántica , Absorción , Luz , Fotones , Factores de Tiempo
13.
Opt Express ; 19(24): 24122-8, 2011 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-22109438

RESUMEN

Femtosecond laser fabrication of controlled three dimensional structures deep in the bulk of diamond is facilitated by a dual adaptive optics system. A deformable mirror is used in parallel with a liquid crystal spatial light modulator to compensate the extreme aberrations caused by the refractive index mismatch between the diamond and the objective immersion medium. It is shown that aberration compensation is essential for the generation of controlled micron-scale features at depths greater than 200 µm, and the dual adaptive optics approach demonstrates increased fabrication efficiency relative to experiments using a single adaptive element.


Asunto(s)
Diamante/química , Diamante/efectos de la radiación , Rayos Láser , Lentes , Refractometría/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Retroalimentación
14.
Opt Express ; 19(24): 24165-70, 2011 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-22109443

RESUMEN

Continuous-wave operation of a diamond Raman laser, intracavity-pumped by a diode-pumped InGaAs semiconductor disk laser (SDL), is reported. The Raman laser, which utilized a 6.5-mm-long synthetic single-crystal diamond, reached threshold for 5.3 W of diode laser pump power absorbed by the SDL. Output power up to 1.3 W at the first Stokes wavelength of 1227 nm was demonstrated with excellent beam quality and optical conversion efficiency of 14.4% with respect to absorbed diode laser pump power. Broad tuning of the Raman laser output between 1217 and 1244 nm was achieved via intracavity tuning of the SDL oscillation wavelength.


Asunto(s)
Diamante/química , Láseres de Semiconductores , Espectrometría Raman/instrumentación , Diamante/efectos de la radiación , Diseño de Equipo , Análisis de Falla de Equipo
15.
Nanoscale ; 3(3): 958-62, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21258697

RESUMEN

A reliable explanation for the underlying mechanism responsible for the persistent aggregation and self-assembly of colloidal 5 nm diamond nanoparticles is critical to the development of nanodiamond-based technologies. Although a number of mechanisms have been proposed, validation has been hindered by the inherent difficulty associated with the identification and characterisation of the inter-particle interfaces. In this paper we present results of high resolution aberration corrected electron microscopy and complementary computer simulations to explicate the features involved, and confirm the electrostatic interaction mechanism as the most probable cause for the formation of agglutinates and agglomerates of primary particles.


Asunto(s)
Diamante/química , Modelos Químicos , Modelos Moleculares , Nanoestructuras/química , Nanoestructuras/ultraestructura , Simulación por Computador , Diamante/efectos de la radiación , Sustancias Macromoleculares/química , Sustancias Macromoleculares/efectos de la radiación , Ensayo de Materiales , Conformación Molecular/efectos de la radiación , Nanoestructuras/efectos de la radiación , Tamaño de la Partícula , Electricidad Estática , Propiedades de Superficie/efectos de la radiación
16.
Med Phys ; 37(3): 1246-53, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20384262

RESUMEN

PURPOSE: To determine the properties of a megavoltage cone-beam CT system using the unflattened beam from a sintered diamond target at 4 and 6 MV. METHODS: A sintered diamond target was used in place of a graphite target as part of an imaging beam line (an unflattened beam from a graphite target) installed on a linear accelerator. The diamond target, with a greater density than the graphite target, permitted imaging at the lower beam energy (4 MV) required with the graphite target and the higher beam energy (6 MV) conventionally used with the tungsten/stainless steel target and stainless steel flattening filter. Images of phantoms and patients were acquired using the different beam lines and compared. The beam spectra and dose distributions were determined using Monte Carlo simulation. RESULTS: The diamond target allowed use of the same beam energy as for treatment, simplifying commissioning and quality assurance. Images acquired with the diamond target at 4 MV were similar to those obtained with the graphite target at 4 MV. The slight reduction in low energy photons due to the higher-Z sintering material in the diamond target had minimal effect on image quality. Images acquired at 6 MV with the diamond target showed a small decrease in contrast-to-noise ratio, resulting from a decrease in the fraction of photons in the beam in the energy range to which the detector is most sensitive. CONCLUSIONS: The diamond target provides images of a similar quality to the graphite target. Diamond allows use of the higher beam energy conventionally used for treatment, provides a higher dose rate for the same beam current, and potentially simplifies installation and maintenance of the beam line.


Asunto(s)
Tomografía Computarizada de Haz Cónico/instrumentación , Diamante/efectos de la radiación , Aumento de la Imagen/instrumentación , Tomografía Computarizada de Haz Cónico/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
Radiat Prot Dosimetry ; 139(4): 580-3, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-20083489

RESUMEN

Nanodiamond thin films were deposited onto Si (100) substrates using Tequila as precursor by pulsed-liquid injection chemical vapour deposition at 850 degrees C. Some samples were exposed to beta particle irradiation in the dose range from 100 to 1600 Gy, and it was found that the thermoluminescence (TL) response is a linear function of dose. The glow curve displays two maxima centred at 170 and 350 degrees C, which does not shift when dose changes, indicating that first-order kinetics processes are involved. From the results, it is concluded that the new nanodiamond films are promising high-dose TL dosimeters.


Asunto(s)
Diamante/química , Diamante/efectos de la radiación , Nanoestructuras/química , Nanoestructuras/efectos de la radiación , Dosimetría Termoluminiscente/métodos , Relación Dosis-Respuesta en la Radiación , México , Dosis de Radiación
18.
Opt Express ; 17(20): 18044-53, 2009 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-19907594

RESUMEN

We present the first optical measurement of a single nitrogen-vacancy (NV) center in a three-dimensional photonic crystal. The photonic crystal, fabricated by self-assembly of polystyrene microspheres, exhibits a photonic stopband that overlaps the NV photoluminescence spectrum. A modified emission spectrum and photon antibunching were measured from the NV centers. Time-resolved fluorescence measurements revealed a 30% increase in the source lifetime. Encapsulation of single NV centers in a three-dimensional photonic crystal is a step towards controlling emission properties of a single photon source.


Asunto(s)
Diamante/química , Modelos Químicos , Nanopartículas/química , Poliestirenos/química , Simulación por Computador , Cristalización/métodos , Diamante/efectos de la radiación , Luz , Nanopartículas/efectos de la radiación , Fotones , Poliestirenos/efectos de la radiación , Dispersión de Radiación
19.
Opt Express ; 16(16): 12139-47, 2008 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-18679489

RESUMEN

We demonstrate broadband light generation in diamond pumped by two-color femtosecond laser pulses. We find that phase matching plays a critical role in the output angle and frequency of the generated sidebands. When a third femtosecond probe pulse is applied to the crystal in the boxed Coherent anti-Stokes Raman Scattering geometry, a two-dimensional array of multi-color beams is generated through the Raman, four-wave mixing, and six-wave-mixing processes. We test the mutual coherence between the generated sidebands. Such coherence, maintained over the broad spectrum, opens possibilities for synthesis of subfemtosecond light waveforms.


Asunto(s)
Diamante/química , Diamante/efectos de la radiación , Rayos Láser , Iluminación/instrumentación , Modelos Teóricos , Transductores , Simulación por Computador , Diseño de Equipo , Análisis de Falla de Equipo
20.
Appl Radiat Isot ; 65(8): 952-8, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17482827

RESUMEN

The utilization of a probe with synthetic diamond as the sensing material developed to measure radiation doses from mammography X-ray beams is described. The computer code system PENELOPE was used, with a geometry model simulating the experimental conditions, to compute the doses from the mammography X-ray beams to the diamond sensing material. The orientation of the diamond sensor to provide maximum absorption of the incident X-ray beam during exposure was also investigated using the PENELOPE code. The results from the theoretical model and experimental measurements are compared.


Asunto(s)
Diamante/química , Diamante/efectos de la radiación , Modelos Químicos , Radiometría/métodos , Programas Informáticos , Simulación por Computador , Relación Dosis-Respuesta en la Radiación , Método de Montecarlo , Dosis de Radiación , Rayos X