Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
PLoS One ; 14(12): e0216023, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31800581

RESUMEN

The Mediterranean Sea is a biodiversity hotspot where intense fishing pressure is associated with high bycatch rates of protected species (sea turtles and cetaceans) and top predators (sharks). Since the conservation of these species has become a priority, fishery scientists are faced with the challenge of reducing incidental catch, which entails high rates of mortality. Among the species threatened by fishing activities, the loggerhead turtle (Caretta caretta) is a charismatic species considered as "vulnerable" at the global scale. In the Mediterranean Sea trawl nets are the gears with the highest probability of catching protected species incidentally. A new flexible Turtle Excluder Device (TED) was tested for the first time on commercial bottom trawlers to assess its effectiveness in reducing bycatch in the Mediterranean Sea. Analysis of the total catches of the hauls made with and without the TED showed that the difference in terms of weight was not significant. The catch of the main commercial species showed similar rates without a significant loss of size (i.e. total length) with the exception of the largest anglerfish (Lophius spp.). The bycatch of control nets included mostly rays and sharks, but never turtles, although the authors learned from the crews of other vessels operating in the same areas at the time of the trials that they had caught some loggerhead turtles. Our study demonstrates that TED scan be adopted without significantly affecting commercial catch. This informs fishers and managers for a practical and effective means that may reduce the bycatch of threatened species in coastal Mediterranean demersal multispecies fisheries. The measures involving gear modifications require significant investment but they are technically feasible and are capable of improving the conservation prospects of these endangered species. Besides ensuring normal earnings, the TED induced a significant reduction of debris and litter in the codend, thus reducing catch sorting time and improving catch quality.


Asunto(s)
Diseño de Equipo/clasificación , Abastecimiento de Alimentos/instrumentación , Tortugas/fisiología , Animales , Conservación de los Recursos Naturales , Especies en Peligro de Extinción , Explotaciones Pesqueras , Mar Mediterráneo
2.
JMIR Mhealth Uhealth ; 7(10): e14198, 2019 10 30.
Artículo en Inglés | MEDLINE | ID: mdl-31670695

RESUMEN

BACKGROUND: The spread of technology and dissemination of knowledge across the World Wide Web has prompted the development of apps for American Sign Language (ASL) translation, interpretation, and syntax recognition. There is limited literature regarding the quality, effectiveness, and appropriateness of mobile health (mHealth) apps for the deaf and hard-of-hearing (DHOH) that pose to aid the DHOH in their everyday communication and activities. Other than the star-rating system with minimal comments regarding quality, the evaluation metrics used to rate mobile apps are commonly subjective. OBJECTIVE: This study aimed to evaluate the quality and effectiveness of DHOH apps using a standardized scale. In addition, it also aimed to identify content-specific criteria to improve the evaluation process by using a content expert, and to use the content expert to more accurately evaluate apps and features supporting the DHOH. METHODS: A list of potential apps for evaluation was generated after a preliminary screening for apps related to the DHOH. Inclusion and exclusion criteria were developed to refine the master list of apps. The study modified a standardized rating scale with additional content-specific criteria applicable to the DHOH population for app evaluation. This was accomplished by including a DHOH content expert in the design of content-specific criteria. RESULTS: The results indicate a clear distinction in Mobile App Rating Scale (MARS) scores among apps within the study's three app categories: ASL translators (highest score=3.72), speech-to-text (highest score=3.6), and hard-of-hearing assistants (highest score=3.90). Of the 217 apps obtained from the search criteria, 21 apps met the inclusion and exclusion criteria. Furthermore, the limited consideration for measures specific to the target population along with a high app turnover rate suggests opportunities for improved app effectiveness and evaluation. CONCLUSIONS: As more mHealth apps enter the market for the DHOH population, more criteria-based evaluation is needed to ensure the safety and appropriateness of the apps for the intended users. Evaluation of population-specific mHealth apps can benefit from content-specific measurement criteria developed by a content expert in the field.


Asunto(s)
Diseño de Equipo/clasificación , Aplicaciones Móviles/normas , Personas con Deficiencia Auditiva/psicología , Diseño de Equipo/normas , Diseño de Equipo/estadística & datos numéricos , Humanos , Aplicaciones Móviles/estadística & datos numéricos , Personas con Deficiencia Auditiva/estadística & datos numéricos , Encuestas y Cuestionarios , Pesos y Medidas/instrumentación
3.
Urology ; 134: 79-83, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31476349

RESUMEN

OBJECTIVE: To better understand the impact of laser fiber-tip configuration on lithotripsy performance, we undertook an in vitro study comparing 3 fiber-tip configurations: (1) new (single-use), (2) cleaved (reusable), and (3) coated (cut with scissors). METHODS: Lithotripsy was performed using a Ho:YAG laser utilizing fragmentation (1 J × 10 Hz) and dusting (0.5 J × 20 Hz) settings. BegoStones were fragmented with a laser fiber advancing at a speed of 1 mm/s (220 seconds of activation). Three fiber-tip configurations were tested: new single-use standard (242 µm core) and cleaved (272 µm core), compared to the same fiber-tip coated/cut flush with scissors, respectively. Study outcome was difference in stone mass before and after each experiment. Power output was measured using a power meter. RESULTS: Fragmentation for new or cleaved fibers was greater than the coated/cut flush fiber-tip (P <.05). For 1 J × 10 Hz and 0.5 J × 20 Hz settings, fragmentation was 59% and 75% higher with new fiber-tip compared to the coated/cut flush fiber-tip, respectively. For 1J × 10 Hz and 0.5 J × 20 Hz settings, fragmentation was 51% and 45% higher with cleaved fiber-tip compared to the coated/cut flush fiber-tip, respectively. Power output at the end of laser activation was higher for new and cleaved fiber-tips. CONCLUSION: New and cleaved laser fibers demonstrated superior lithotripsy performance compared to fibers that were coated/cut flush with scissors. Cutting single-use laser fibers risks damaging the fiber-tip which can disperse the energy and reduce lithotripsy efficiency.


Asunto(s)
Diseño de Equipo , Láseres de Estado Sólido , Litotripsia por Láser , Cálculos Urinarios/terapia , Diseño de Equipo/efectos adversos , Diseño de Equipo/clasificación , Análisis de Falla de Equipo/métodos , Humanos , Láseres de Estado Sólido/normas , Láseres de Estado Sólido/uso terapéutico , Litotripsia por Láser/efectos adversos , Litotripsia por Láser/instrumentación , Litotripsia por Láser/métodos , Ensayo de Materiales/métodos
5.
Aktuelle Urol ; 45(3): 218-20, 2014 May.
Artículo en Alemán | MEDLINE | ID: mdl-24902071

RESUMEN

BACKGROUND: Complications after endoscopic retrieval of kidney and ureter stones are obviously related to the size of the stones as well as the experience of the surgeon and other factors. During the procedure it is sometimes difficult for surgeons to estimate stone size and therefore give prognostic advises. The visual perception of the stone size depends on the shape, colour, distance to the renoscope and dilatation of the ureter. This is the so-called binding problem, because shape, color and direction of motion are processed separately by different population of optical neurons. In order to establish a better prognostic ratio, especially for less experienced surgeons we established an intraoperative semi-quantitative measurement of the stone size supported by a stone basket. MATERIALS AND METHODS: We modified the tipped nitinol stone baskets from the company Urotech with diameters of 2.5, 3.0 and 4 Ch. The handle of this basket has a spring mechanism, which automatically closes the basket and provides a predefined fixation force of the stones within the basket. On the handle we established a non-linear scale in mm by grabbing standardized balls or standardized screws. RESULTS: The scales are nonlinear because of the nonlinear relation between the diameter of the stone and the distance of the slider. Also the scales differ in between the basket size, because of the different strain conditions due to the different wire sizes and materials or the spring and basket. CONCLUSIONS: This scale could be an important orientation for a surgeon during endourological procedures to estimate stone sizes. It could be used also for the documentation of the size of fragments after an endourologic lithotripsy and could help in the decision for or against an extraction. Finally it could be very interesting for other disciplines like gastroenterology. The scale should be validated in further clinical trials.


Asunto(s)
Aleaciones , Diseño de Equipo/clasificación , Cálculos Renales/clasificación , Cálculos Renales/terapia , Cálculos Ureterales/clasificación , Cálculos Ureterales/terapia , Ureteroscopía/instrumentación , Humanos , Cálculos Renales/diagnóstico , Percepción del Tamaño , Cálculos Ureterales/diagnóstico
6.
J Invasive Cardiol ; 26(2): 64-9, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24486663

RESUMEN

OBJECTIVES: The aim of this study was to determine the in vivo longitudinal strength and conformability of various stent platforms following stent implantation in rabbit iliac arteries. BACKGROUND: Recently, longitudinal coronary stent deformation has been highlighted and bench tests have demonstrated differences in longitudinal strength among various stent platforms. However, this has not been investigated in an in vivo setting. This is of interest because there may be a trade-off between longitudinal strength and conformability. METHODS: We evaluated 4 types of commercially available stents: Multi-Link 8 (Abbott Vascular); Omega (Boston Scientific); Integrity (Medtronic); and Nobori (Terumo Corporation). To investigate the longitudinal strength, constant axial force was applied to the stent edge by a guiding catheter after deployment in a rabbit iliac artery. The amount of longitudinal stent deformation was calculated by measuring stent length. In order to evaluate conformability, stents were deployed crossing over the iliac bifurcation and the bifurcation angles were measured before and after stent implantation. If the change in the angle was small, the stent was considered to be more conformable. RESULTS: The Omega stent demonstrated significantly greater longitudinal compression compared with other stents (Omega, 17.4 ± 9.3%; Multi-Link 8, 2.8 ± 2.3%; Integrity, 2.8 ± 1.4%; Nobori, 3.8 ± 3.2%; P=.01), but Omega showed better conformability, as evidenced by the smallest percent change in the bifurcation angle (Omega, 12.7 ± 0.8%; Multi-Link 8, 25.7 ± 2.4%; Integrity, 28.3 ± 1.1%; Nobori, 28.1 ± 6.8%; P=.03). CONCLUSION: In this rabbit model, the Omega stent, which has the platform of the Element stent, showed less longitudinal strength but greater conformability compared with the other stent platforms.


Asunto(s)
Cateterismo Periférico/instrumentación , Stents Liberadores de Fármacos/normas , Diseño de Equipo/normas , Arteria Ilíaca , Animales , Stents Liberadores de Fármacos/clasificación , Diseño de Equipo/clasificación , Ensayo de Materiales/métodos , Modelos Animales , Conejos , Resistencia a la Tracción
7.
J Clin Psychiatry ; 74(1): 38-42, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23419224

RESUMEN

Electroconvulsive therapy (ECT) is a safe and highly effective treatment for management of acute episodes of a variety of serious mental disorders, particularly for major depressive episodes that are resistant to multiple interventions with treatment alternatives. As such, the National Network of Depression Centers (NNDC), a consortium of major academic centers with interest and expertise in this area, believes there is an important public health need for ECT to remain available for clinical use. As with all medical devices, ECT is regulated by the US Food and Drug Administration (FDA), which is presently involved in formulating a proposed rule as to how such devices should be classified. Since such classification may have substantial effects on the availability of ECT to patients for whom it is clinically indicated, the NNDC has reviewed the information provided by the FDA to its Advisory Panel, as well as the subsequent deliberations of the Panel itself at a January 2011 public hearing. This review indicates that the FDA may have substantially underestimated the efficacy of ECT as a means to produce large clinical improvements for individuals suffering from severe major depressive disorders and that such an underestimate likely affected the Panel's willingness to recommend reclassification of ECT devices to a less restrictive category. In addition, the NNDC's review generates support for a variety of methods by which the safety of ECT can be ensured, which is an essential requirement for such reclassification.


Asunto(s)
Comités Consultivos , Trastorno Depresivo Mayor/terapia , Trastorno Depresivo Resistente al Tratamiento/terapia , Terapia Electroconvulsiva/instrumentación , Diseño de Equipo/clasificación , United States Food and Drug Administration , Enfermedad Aguda , Amnesia/diagnóstico , Amnesia/etiología , Trastorno Depresivo Mayor/diagnóstico , Trastorno Depresivo Mayor/psicología , Trastorno Depresivo Resistente al Tratamiento/diagnóstico , Trastorno Depresivo Resistente al Tratamiento/psicología , Aprobación de Recursos , Terapia Electroconvulsiva/efectos adversos , Humanos , Pruebas Neuropsicológicas , Resultado del Tratamiento , Estados Unidos
9.
Perfusion ; 22(3): 167-71, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-18018395

RESUMEN

Medical devices are one of the most highly regulated products in the world. Despite this, there is an unacceptable rate of medical error. Not solely due to the device, but also the user and/or system in which it is used. The current approach to testing of medical devices must be progressed so the concept of user beware is changed to user be aware. All health professionals should be well informed as to the various aspects of each new device. Also, testing in research facilities that are equipped with qualified personnel and the proper testing methods should be supported. The outcome of good research then can be translated into good practice. This implementation requires constant communication for quality improvements from and to professional committees, educational leaders, and experts in the field. Medical devices are thoroughly tested before they are marketed, but we, as clinicians and users, must continuously examine and improve the design of equipment, procedures, personnel, and the environment in which we work to optimize medical systems. Once the device is on the market, changes or modifications are costly. Finally, a factor for success in critical testing of new devices is not what is technically possible, but rather making a concrete contribution to improving medical problems.


Asunto(s)
Equipos y Suministros , Estudios de Evaluación como Asunto , Errores Médicos/prevención & control , Vigilancia de Productos Comercializados/métodos , Evaluación de la Tecnología Biomédica , Diseño de Equipo/clasificación , Diseño de Equipo/normas , Falla de Equipo/estadística & datos numéricos , Seguridad de Equipos/clasificación , Seguridad de Equipos/normas , Equipos y Suministros/normas , Ética en Investigación , Unión Europea , Humanos , Servicios de Información/normas , Vigilancia de Productos Comercializados/normas , Control de Calidad , Administración de la Seguridad/métodos
10.
J Anesth ; 20(4): 268-73, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-17072690

RESUMEN

PURPOSE: The use of low-flow anesthesia causes a discrepancy between the delivered fraction (FD) and the inspired fraction (FI) of inhaled gases. We compared the FI/FD ratios of a new circle (fresh gas inlet located between the inspiratory valve and the patient) to those of the conventional circle (fresh gas inlet located between the inspiratory valve and the CO2 absorber) in low-flow isoflurane and sevoflurane anesthesia, using three anesthetic machines (Dräger NM-GS, Dräger Fabius-GS, and ACOMA KMA-1300-III). METHODS: Eighty-two patients were randomly assigned to three experimental groups. For experiment 1, 32 patients were allocated to the NM-GS conventional/new, NM-GS new/conventional, ACOMA conventional/new, and ACOMA new/conventional groups. For experiment 2, 14 patients were allocated to ACOMA conventional/conventional and ACOMA new/new groups to measure isoflurane FI/FD ratios. For experiment 3, 36 patients were allocated to ACOMA conventional/conventional, ACOMA new/new, Fabius conventional/conventional, and Fabius new/new to measure sevoflurane FI/FD ratios. RESULTS: In experiment 1, the NM-GS showed no significant changes in the FI/FD ratios. However, in the ACOMA, the new circle improved the FI/FD ratio. In experiment 2, the isoflurane FI/FD ratios in the new circle of the ACOMA were significantly higher than those in the conventional circle. In experiment 3, the sevoflurane FI/FD ratios in the new circle of both the ACOMA and the Fabius were significantly higher than those in the conventional circles. CONCLUSION: The positioning of the fresh gas inlet between the inspiratory valve and the patient improved the FI/FD ratios of both isoflurane and sevoflurane during low-flow anesthesia in two decoupling-style anesthetic machines (ACOMA and Fabius).


Asunto(s)
Anestesia por Circuito Cerrado/instrumentación , Anestesia por Inhalación/instrumentación , Anestesiología/instrumentación , Adulto , Anciano , Anestesia General , Anestésicos por Inhalación/administración & dosificación , Anestésicos por Inhalación/análisis , Diseño de Equipo/clasificación , Diseño de Equipo/tendencias , Femenino , Humanos , Isoflurano/administración & dosificación , Isoflurano/análisis , Masculino , Éteres Metílicos/administración & dosificación , Éteres Metílicos/análisis , Persona de Mediana Edad , Sevoflurano
11.
Semin Pediatr Surg ; 15(4): 293-301, 2006 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17055960

RESUMEN

An examination of and recommendations regarding the approval process for medical devices are presented. The typical pathways and hurdles laid out by the Federal Food and Drug Administration (FDA) are discussed, and options for marketing and use of medical devices are addressed. The first step in the regulatory process is to establish that the new product is, in fact, a medical device. From there, the appropriate classification and the corresponding level of regulatory control that will be required can be identified. The appropriate marketing application will be submitted and is supported by the data necessary to reasonably assure safety and effectiveness. Once the application is submitted, reviewed, and eventually approved, the manufacturer may legally market and sell the medical device. The active involvement of physicians as advisors and innovators in medical device development is imperative to the successful development of safe and effective medical devices. Physicians also fulfill the important obligation of adverse event reporting with all medical devices that they use. The pediatric physician should additionally be aware of the FDA regulations and expectations with respect to devices that will serve pediatric patient populations, of the regulatory options for approval and unapproved use for some devices, and of the special measures taken to protect the rights, safety, and welfare of pediatric patients participating in investigational studies.


Asunto(s)
Aprobación de Recursos , Equipo Quirúrgico , Instrumentos Quirúrgicos , United States Food and Drug Administration , Altruismo , Niño , Aprobación de Recursos/legislación & jurisprudencia , Diseño de Equipo/clasificación , Diseño de Equipo/instrumentación , Diseño de Equipo/normas , Seguridad de Equipos/instrumentación , Seguridad de Equipos/normas , Humanos , Equipo Quirúrgico/clasificación , Equipo Quirúrgico/normas , Instrumentos Quirúrgicos/clasificación , Instrumentos Quirúrgicos/normas , Estados Unidos , United States Food and Drug Administration/legislación & jurisprudencia
13.
Acta Anaesthesiol Belg ; 57(4): 419-28, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-17236645

RESUMEN

In this review paper, the authors analyse advantages, pitfalls and economical considerations related to depth of anaesthesia monitoring. They first describe the most widely distributed monitors in Europe, and the physiological basis of each index. The optimal use of those monitors and their demonstrated clinical benefits are detailed, as well as the circumstances that can lead to erroneous information or interpretation. Knowledge of patients and practitioners, as well as beliefs and expectations regarding depth of anaesthesia monitoring are discussed. Finally, the authors give their own opinion regarding the use of depth of anaesthesia monitoring, according to clinical benefit and economical considerations.


Asunto(s)
Encéfalo/fisiología , Monitoreo Intraoperatorio/instrumentación , Anestesia/efectos adversos , Anestesiología/instrumentación , Diseño de Equipo/clasificación , Diseño de Equipo/economía , Europa (Continente) , Humanos , Monitoreo Intraoperatorio/economía
14.
Br J Sports Med ; 39(5): 278-81, 2005 May.
Artículo en Inglés | MEDLINE | ID: mdl-15849291

RESUMEN

OBJECTIVES: To present a grading system of the protection offered by various types of mouthguard, together with an indication of associated risks, in order to make athletes aware of the consequences of improper or no mouth protection. METHODS: A review of the literature on mouthguards, mouthguard materials, and novel laminates for mouthguards was carried out as it was apparent that information on mouthguards was lacking. Studies on stock (or unfitted) mouthguards, mouth formed (boil and bite) mouthguards, and custom mouthguards are reviewed. RESULTS: A scale of protection offered by various mouthguards and novel laminates has been produced, where 0 indicates no mouthguard and 10 indicates a custom made mouthguard offering excellent protection. CONCLUSIONS: From work carried out on laminates and the manufacturing processes of mouthguards, it became apparent that information was lacking to enable athletes make informed decisions about the best oral protection for their chosen sport.


Asunto(s)
Traumatismos en Atletas/prevención & control , Protectores Bucales/normas , Diseño de Equipo/clasificación , Diseño de Equipo/normas , Estudios de Evaluación como Asunto , Humanos , Protectores Bucales/clasificación , Equipo Deportivo/clasificación , Equipo Deportivo/normas , Traumatismos de los Dientes/prevención & control
15.
Fed Regist ; 69(237): 71702-4, 2004 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-15587485

RESUMEN

The Food and Drug Administration (FDA) is classifying the implantable radiofrequency transponder system for patient identification and health information into class II (special controls). The special control that will apply to the device is the guidance document entitled "Class II Special Controls Guidance Document: Implantable Radiofrequency Transponder System for Patient Identification and Health Information." The agency is classifying the device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of the device. Elsewhere in this issue of the Federal Register, FDA is publishing a notice of availability of a guidance document that is the special control for this device.


Asunto(s)
Electrónica Médica/clasificación , Registros Médicos , Sistemas de Identificación de Pacientes/clasificación , Radio/clasificación , Electrónica Médica/instrumentación , Electrónica Médica/legislación & jurisprudencia , Diseño de Equipo/clasificación , Seguridad de Equipos/clasificación , Humanos , Sistemas de Identificación de Pacientes/legislación & jurisprudencia , Radio/instrumentación , Radio/legislación & jurisprudencia , Estados Unidos , United States Food and Drug Administration
16.
Fed Regist ; 69(226): 68254-5, 2004 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-15562554

RESUMEN

The Food and Drug Administration (FDA) is classifying newborn screening test systems for amino acids, free carnitine, and acylcarnitines using tandem mass spectrometry into class II (special controls). The special control that will apply to the device is the guidance document entitled "Class II Special Controls Guidance Document: Newborn Screening Test Systems for Amino Acids, Free Carnitine, and Acylcarnitines Using Tandem Mass Spectrometry." The agency is taking this action in response to a petition submitted under the Federal Food, Drug, and Cosmetic Act (the act) as amended by the Medical Device Amendments of 1976, the Safe Medical Devices Act of 1990, the Food and Drug Administration Modernization Act of 1997, and the Medical Device User Fee and Modernization Act of 2002. The agency is classifying the device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of the device. Elsewhere in this issue of the Federal Register, FDA is publishing a notice of availability of a guidance document that is the special control for this device.


Asunto(s)
Química Clínica/instrumentación , Espectrometría de Masas/instrumentación , Tamizaje Neonatal/instrumentación , Toxicología/instrumentación , Aminoácidos/sangre , Carnitina/análogos & derivados , Carnitina/sangre , Química Clínica/clasificación , Química Clínica/legislación & jurisprudencia , Diseño de Equipo/clasificación , Seguridad de Equipos/clasificación , Humanos , Recién Nacido , Espectrometría de Masas/clasificación , Errores Innatos del Metabolismo/sangre , Tamizaje Neonatal/clasificación , Tamizaje Neonatal/legislación & jurisprudencia , Toxicología/clasificación , Toxicología/legislación & jurisprudencia , Estados Unidos , United States Food and Drug Administration
17.
Fed Regist ; 67(218): 68510-2, 2002 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-12428642

RESUMEN

The Food and Drug Administration (FDA) is classifying the intraoral devices for snoring and/or obstructive sleep apnea into class II (special controls). These devices are used to control or treat simple snoring and/or obstructive sleep apnea. This classification is based on the recommendations of the Dental Devices Panel (the Panel), and is being taken to establish sufficient regulatory controls that will provide reasonable assurance of the safety and effectiveness of these devices. This action is being taken under the Federal Food, Drug, and Cosmetic Act (the act), as amended by the Medical Device Amendments of 1976 (the 1976 amendments), the Safe Medical Devices Act of 1990 (the SMDA), and the Food and Drug Administration Modernization Act of 1997 (FDAMA). Elsewhere in this issue of the Federal Register, FDA is publishing a notice of availability of the guidance document that will serve as the special control for this final rule.


Asunto(s)
Dispositivos para el Autocuidado Bucal/clasificación , Apnea Obstructiva del Sueño/terapia , Ronquido/terapia , Aprobación de Recursos , Diseño de Equipo/clasificación , Seguridad de Equipos/clasificación , Humanos , Estados Unidos , United States Food and Drug Administration
18.
Appl Ergon ; 32(4): 379-87, 2001 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-11461039

RESUMEN

Foot injuries and deformations are more frequent at higher levels of sport climbing. These are accepted as unavoidable because it is assumed that, for optimal performance, a prerequisite is the wearing of a shoe, which is too tight and has an unnatural shape. Based on a biomechanical analysis, we came up with a different approach to shoe design. By using regional thinning of the sole, easy flexion and extension of the toes is made possible. The form of the shoe conforms to the natural form of the foot, the shoe closure provides a close fit for feet with width differences of up to 20 mm and a shoe-sizing system was developed. After testing prototypes, we conclude that the new shoe design can contribute to the prevention of foot injuries and deformations in sport climbing.


Asunto(s)
Traumatismos en Atletas/prevención & control , Diseño de Equipo/normas , Traumatismos de los Pies/prevención & control , Montañismo , Zapatos/normas , Fenómenos Biomecánicos , Diseño de Equipo/clasificación , Pie/fisiología , Humanos , Zapatos/clasificación
19.
J Okla Dent Assoc ; 92(2): 33-8, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11808071

RESUMEN

Ultrasonic instrumentation has added a new horizon to endodontic treatment possibilities. It is a tool in the arsenal of instruments currently used by almost every endodontist in the United States. The use of ultrasonic instrumentation was formerly confined solely to periodontics, but has slowly come to be an indispensable tool in endodontics as well.


Asunto(s)
Tratamiento del Conducto Radicular/instrumentación , Terapia por Ultrasonido/instrumentación , Cavidad Pulpar/patología , Diseño de Equipo/clasificación , Cuerpos Extraños/terapia , Humanos , Técnica de Perno Muñón/instrumentación , Pulpectomía/instrumentación , Retratamiento , Obturación Retrógrada/instrumentación , Obturación Retrógrada/métodos , Materiales de Obturación del Conducto Radicular/química , Tratamiento del Conducto Radicular/métodos , Propiedades de Superficie , Terapia por Ultrasonido/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA