Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.752
Filtrar
1.
J Am Heart Assoc ; 13(9): e034249, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38639354

RESUMEN

This comprehensive review explores the incidence, pathophysiology, and management of atrial fibrillation (AF) following percutaneous closure of patent foramen ovale (PFO). Although AF is considered a common adverse event post PFO closure, its incidence, estimated at <5%, varies based on monitoring methods. The review delves into the challenging task of precisely estimating AF incidence, given subclinical AF and diverse diagnostic approaches. Notably, a temporal pattern emerges, with peak incidence around the 14th day after closure and a subsequent decline after the 45th day, mimicking general population AF trends. The pathophysiological mechanisms behind post PFO closure AF remain elusive, with proposed factors including local irritation, device-related interference, tissue stretch, and nickel hypersensitivity. Management considerations encompass rhythm control, with flecainide showing promise, and anticoagulation tailored to individual risk profiles. The authors advocate for a personalized approach, weighing factors like age, comorbidities, and device characteristics. Notably, postclosure AF is generally considered benign, often resolving spontaneously within 45 days, minimizing thromboembolic risks. Further studies are required to refine understanding and provide evidence-based guidelines.


Asunto(s)
Fibrilación Atrial , Foramen Oval Permeable , Humanos , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/epidemiología , Fibrilación Atrial/etiología , Fibrilación Atrial/terapia , Fibrilación Atrial/diagnóstico , Foramen Oval Permeable/epidemiología , Foramen Oval Permeable/fisiopatología , Foramen Oval Permeable/terapia , Foramen Oval Permeable/complicaciones , Incidencia , Cateterismo Cardíaco/efectos adversos , Factores de Riesgo , Dispositivo Oclusor Septal/efectos adversos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/fisiopatología
2.
Catheter Cardiovasc Interv ; 103(6): 934-942, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38584522

RESUMEN

BACKGROUND: Transcatheter closure of the patent ductus arteriosus (PDA) in premature infants is currently dependent on fluoroscopic guidance and transportation to the catheterization laboratory. AIM: We describe a new echocardiographically guided technique to allow our team to move to the bedside at the neonatal intensive care unit (NICU) of the referring center for percutaneous treatment of PDA in premature infants. METHODS: This is a single-center, retrospective, primarily descriptive analysis. Clinical details about the procedure, its outcomes, and complications were collected. RESULTS: Fifty-eight neonates with a median weight of 1110 g (range 730-2800) and postnatal age of 28 days (range 9-95) underwent percutaneous PDA closure. Five of them were treated in our center with ultrasound guidance only and the other 53 in 18 different neonatology units in 12 towns. The median duration of the procedure was 40 min (range 20-195 min). There were no procedural deaths. There was one residual shunt for 3 weeks, in all other patients the duct closed completely in the first few hours after the intervention. In one patient the procedure had to be interrupted because of a pericardial effusion which had to be drained, the PDA was closed successfully interventionally 5 days later. One device-related aortic coarctation had to be stented. One embolization and one late migration occurred and required treatment. CONCLUSIONS: Echocardiographically guided transcatheter closure of the PDA in prematures was repeatedly possible and allowed that the procedure is performed at the bedside at the NICU with an acceptable rate of complications.


Asunto(s)
Cateterismo Cardíaco , Conducto Arterioso Permeable , Ultrasonografía Intervencional , Humanos , Conducto Arterioso Permeable/terapia , Conducto Arterioso Permeable/diagnóstico por imagen , Conducto Arterioso Permeable/fisiopatología , Recién Nacido , Estudios Retrospectivos , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Resultado del Tratamiento , Edad Gestacional , Valor Predictivo de las Pruebas , Masculino , Femenino , Factores de Tiempo , Índice de Severidad de la Enfermedad , Recien Nacido Prematuro , Recien Nacido Extremadamente Prematuro , Unidades de Cuidado Intensivo Neonatal , Sistemas de Atención de Punto , Pruebas en el Punto de Atención , Dispositivo Oclusor Septal , Lactante
3.
J Cardiovasc Electrophysiol ; 35(5): 1046-1049, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38468182

RESUMEN

INTRODUCTION: Left atrial appendage (LAA) closure (LAAC) is considered a viable alternative to anticoagulation therapy for stroke prevention in nonvalvular atrial fibrillation, we report a case with a less common shunt resulting from a device-related coronary artery-appendage fistula (CAAF) following LAAC. METHODS AND RESULTS: A 67-year-old male with a history of LAAC was referred to our emergency room with recurrent chest pain and palpitations and was diagnosed with ischemic angina pectoris. Subsequent coronary angiography (CAG) revealed 70% in-stent restenosis and an abnormal shunt of contrast originating from the left circumflex artery (LCA) to the LAA tip which did not exist before. The restenosis was successfully dilated using a drug-coated balloon, the procedure was safely completed without pericardial effusion. The patient had been implanted with a LAmbre occluder (Lifetech Scientific Corp.) in the previous LAAC procedure. This occluder had a lobe-disk design, and the distal umbrella was not fully opened after release, particularly in the lower portion. This could make the hooks embedded on the umbrella contact the LAA wall more tightly, possibly resulting in microperforation and coincidental impingement of the LCA. The epicardial adipose and hyperplastic tissue then chronically wrapped the perforated site, prevented blood outflow into the epicardium, and ultimately formed a CAAF. CONCLUSION: CAAF is a rare complication after LAAC but may be underestimated, especially for lobe-disk designed occluders. Therefore, CAG is perhaps necessary to detect this complication.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Anciano , Humanos , Masculino , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/fisiopatología , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Vasos Coronarios/diagnóstico por imagen , Cierre del Apéndice Auricular Izquierdo , Diseño de Prótesis , Dispositivo Oclusor Septal/efectos adversos , Resultado del Tratamiento , Fístula Vascular/diagnóstico por imagen , Fístula Vascular/etiología
6.
Catheter Cardiovasc Interv ; 103(5): 741-750, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38451154

RESUMEN

BACKGROUND: The GCA is a well performing device in terms of efficacy despite complex anatomies (aortic rim <5 mm and ASD diameter >17 mm) with a good safety profile. AIMS: To evaluate atrial septal defect (ASD) features impacting on right disc device thrombosis in patients who underwent Gore Cardioform ASD Occluder (GCA) implantation. METHODS: A total of 44 consecutive patients undergoing percutaneous ASD with GCA device from January 2020 to September 2022 at our tertiary care Center were evaluated. The minimum follow-up was 6 months. RESULTS: The patients were stratified in two groups according to a cut-off value of ASD diameter equal to 20 mm at sizing balloon, derived from ROC analysis (AUC = 0.894; p = 0.024). Baseline characteristics were comparable between groups in terms of age, sex, weight, height, and interatrial septum dimensions. Patients with ASD > 20 mm (n = 9) had a higher ASD/device dimension ratio, both at echocardiography (p = 0.009) and at sizing balloon (p = 0.001), longer fluoroscopic time (p = 0.022), and higher incidence of device thrombosis (0.006). Right disc thrombosis was observed in three patients of the ASD > 20 mm group, always in the inferior portion of the right disc. On univariate analysis, ASD diameter at sizing balloon (OR 1.360; p = 0.036) was the only positive predictor of device thrombosis. CONCLUSIONS: Right disc thrombosis of the GCA device may be under-recognized at follow-up, hence deserving clinical attention, especially in those patients with larger ASD diameters.


Asunto(s)
Defectos del Tabique Interatrial , Dispositivo Oclusor Septal , Humanos , Ecocardiografía Transesofágica , Resultado del Tratamiento , Cateterismo Cardíaco/efectos adversos , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interatrial/terapia
8.
Int J Cardiol ; 405: 131939, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38458388

RESUMEN

BACKGROUND: Advances in imaging have led to procedural optimization of left atrial appendage closure (LAAC). Contrast-free approaches, guided merely by echocardiography, have been established, however data on this topic remains scarce. In this analysis, we assessed contrast-free procedural results with the LAMBRE LAAC device. METHODS: The multicenter retrospective BoBoMa (Bonn/Bordeaux/Mainz)-Registry included a total of 118 patients that underwent LAAC with LAMBRE devices omitting contrast-dye. Baseline and echocardiographic characteristics as well as intra- and postprocedural complications and outcomes were assessed. RESULTS: Patients were at a mean age of 77.5 ± 7.5 years with high thromboembolic and bleeding risk (CHADS-VASc-score 4.6 ± 1.4, HAS-BLED-score 3.7 ± 1.0, respectively). Renal function was impaired with a mean glomerular filtration rate (GFR) of 50 ± 22 ml/min. Mean procedural time was 47.2 ± 37.5  minutes with a mean radiation dose of 4.75 ± 5.25 Gy*cm2. Device success, defined as proper deployment in a correct position, was achieved in 97.5% (115/118) of cases with repositioning of the occluder in 7.6% (9/118) and resizing in 3.4% (4/118) of cases. No relevant peri-device leakage (>3 mm) was observed with 42% of occluders being implanted in an ostial position. Periprocedural complications occurred in 6.8% (8/118) of cases, including two cases of device embolization and one case of clinically-relevant pericardial effusion requiring surgical intervention. Other complications included pericardial effusion (2.5%, 3/118) and vascular access site complications (1.7%, 2/118). CONCLUSION: Echocardiography-guided contrast-free LAAC using the LAMBRE device is safe and feasible. Further prospective studies including the direct comparison of devices as well as imaging techniques are warranted in contrast-free LAAC.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Dispositivo Oclusor Septal , Humanos , Apéndice Atrial/cirugía , Apéndice Atrial/diagnóstico por imagen , Masculino , Femenino , Anciano , Estudios Retrospectivos , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Anciano de 80 o más Años , Sistema de Registros , Resultado del Tratamiento , Ecocardiografía Transesofágica/métodos , Medios de Contraste/administración & dosificación , Estudios de Seguimiento
9.
Turk Kardiyol Dern Ars ; 52(2): 149-152, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38465527

RESUMEN

Transcatheter closure of muscular ventricular septal defects (VSD) remains a safe and effective method with low complication rates. However, device migration can pose a significant challenge to interventional cardiologists due to potential mortal consequences. A 21-year-old female presented to our clinic with exertional dyspnea and was diagnosed with a muscular VSD. The defect was percutaneously closed using an Amplatzer occluder device. On the first post-procedural day, the patient experienced repeated episodes of coughing and mild hemoptysis. Imaging revealed migration of the VSD occluder device to the right pulmonary artery (PA). Percutaneous retrieval of the device was then decided upon. The right PA was accessed using a hydrophilic guidewire and a pigtail catheter. This catheter was exchanged for an 8-Fr sheathless guide catheter, and a 6-Fr Judkins right catheter was advanced into the right PA through the sheathless guide catheter using the mother-and-child technique. Multiple attempts using a snare were made to retrieve the migrated device. Eventually, the proximal marker point, the hub of the device, was grasped and pulled back from the PA, then externalized through the sheath without the need for surgical cutdown. Our report represents a case of complete percutaneous retrieval of an embolized VSD occluder device from the PA.


Asunto(s)
Defectos del Tabique Interventricular , Dispositivo Oclusor Septal , Femenino , Humanos , Adulto Joven , Adulto , Dispositivo Oclusor Septal/efectos adversos , Arteria Pulmonar/diagnóstico por imagen , Defectos del Tabique Interventricular/diagnóstico por imagen , Defectos del Tabique Interventricular/cirugía , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Catéteres , Resultado del Tratamiento
11.
Circ J ; 88(5): 663-671, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38325819

RESUMEN

BACKGROUND: Complications arising from transcatheter closure of perimembranous ventricular septal defects (pmVSD) in children, such as residual shunts and aortic regurgitation (AR), have been observed. However, the associated risk factors remain unclear. This study identified risk factors linked with residual shunts and AR following transcatheter closure of pmVSD in children aged 2-12 years.Methods and Results: The medical records of 63 children with pmVSD and a pulmonary-to-systemic blood flow ratio <2.0 who underwent transcatheter closure between 2011 and 2018 were analyzed with a minimum 3-year follow-up. The success rate of transcatheter closure was 98.4%, with no emergency surgery, permanent high-degree atrioventricular block, or mortality. Defects ≥4.5 mm had significantly higher odds of persistent residual shunt (odds ratio [OR] 6.85; P=0.03). The use of an oversize device (≥1.5 mm) showed a trend towards reducing residual shunts (OR 0.23; P=0.06). Age <4 years (OR 27.38; 95% confidence interval [CI] 2.33-321.68) and perimembranous outlet-type VSD (OR 11.94, 95% CI 1.10-129.81) were independent risk factors for AR progression after closure. CONCLUSIONS: Careful attention is crucial for pmVSDs ≥4.5 mm to prevent persistent residual shunts in transcatheter closure. Assessing AR risk, particularly in children aged <4 years, is essential while considering the benefits of pmVSD closure.


Asunto(s)
Cateterismo Cardíaco , Defectos del Tabique Interventricular , Humanos , Defectos del Tabique Interventricular/cirugía , Preescolar , Niño , Factores de Riesgo , Masculino , Femenino , Cateterismo Cardíaco/efectos adversos , Estudios Retrospectivos , Dispositivo Oclusor Septal/efectos adversos , Resultado del Tratamiento , Insuficiencia de la Válvula Aórtica/etiología , Factores de Edad , Factores de Tiempo , Estudios de Seguimiento , Complicaciones Posoperatorias/etiología
12.
J Invasive Cardiol ; 36(4)2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38412436

RESUMEN

Atrial septal abnormalities are common congenital lesions that remain asymptomatic in many patients until adulthood. Adults with atrial septal defects (ASD) most commonly have ostium secundum ASD. Transcatheter closure has become increasingly popular in recent years as a successful alternative method to surgery for treating ASD and patent foramen ovale (PFO). The overall rate of ASD transcatheter closure device embolization has been reported to be less than 1%; however, retrieving the device via surgery or by trans-catheter route can be necessary. The current manuscript describes a systematic review of the techniques used to retrieve ASD closure devices, as well as their success rates, complications, and limitations. A comprehensive search was performed covering various databases including PubMed, MEDLINE, SCOPUS, Google Scholar, and Cochrane Library from inception until April 2022 for English-published case reports, case series, and experimental studies investigating the indications, safety, and limitations of ASD closure and ASD device retrieval by trans-catheter approaches. Finally, 20 studies were included in our review. Our findings showed that most of the studies used a single snare technique; of these, all but one reported 100% success. Double tool retrieval methods (snare plus snare, snare plus bioptome, or snare plus forceps) and the gooseneck snare technique yielded 100% success. One study that used the lasso technique reported unsuccessful retrieval and the need for surgical intervention. More recently, the novel "coronary wire trap technique" was introduced, which provides a simpler method for embolized device removal by trapping the device for retrieval using coronary wire.


Asunto(s)
Foramen Oval Permeable , Defectos del Tabique Interatrial , Dispositivo Oclusor Septal , Adulto , Humanos , Foramen Oval Permeable/cirugía , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Defectos del Tabique Interatrial/diagnóstico , Defectos del Tabique Interatrial/cirugía , Catéteres Cardíacos
13.
J Invasive Cardiol ; 36(4)2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38412438

RESUMEN

OBJECTIVES: Percutaneous closure of a patent foramen ovale (PFO) for the prevention of recurrent paradoxical thromboembolic events has been shown to be safe and effective in randomized controlled trials. However, it remains uncertain if differences in the structure and design of the occluder devices impact the outcomes. The aim of this study was to compare results of percutaneous PFO closure using 2 widely used double-disc occluders. METHODS: Consecutive patients who underwent percutaneous PFO closure with the Abbott Amplatzer occluder (APO) or the Occlutech Figulla-Flex-II occluder (OPO) at the Heart Center Lucerne between February 2017 and December 2022 were included in a registry. The primary endpoint was effective closure of the PFO, defined as a residual shunt grade 0 or 1, assessed by contrast echocardiogram at 6-month follow-up. Secondary endpoints included procedural efficacy/safety and major adverse cardiovascular events during the hospital stay and at 6-month follow-up. RESULTS: One hundred ninety-three consecutive patients (mean age 51.7 ± 12.5 years; 39% women; Risk of Paradoxical Embolism (RoPE) score = 7, IQR = 6-8) underwent percutaneous PFO closure with the APO (120 patients, 62.2%) or the OPO (73 patients, 37.8%). Main indications for closure were crypotogenic stroke in 168 patients (87.1%) and peripheral embolism in 13 patients (6.7%). At baseline, right-to-left shunt (RLS) greater than or equal to grade 2 was present in 189 patients (97.9%). Immediate procedural success was 99.5%. In 1 patient, an air embolism occurred during positioning of the APO occluder with transient chest pain and electrocardiogram changes, but without further sequelae to the patient. At 6-month follow-up, effective closure was achieved in 185 patients (95.8%; APO: 96.6% vs OPO: 94.5%, P = .30). Rates of atrial fibrillation and recurrent thromboembolic events were 4.2 and 0.5%, respectively. CONCLUSIONS: PFO closure is safe and effective when performed with either the self-expanding Abbott Amplatzer or Occlutech Figulla Flex II PFO occluder.


Asunto(s)
Foramen Oval Permeable , Dispositivo Oclusor Septal , Accidente Cerebrovascular , Tromboembolia , Humanos , Femenino , Adulto , Persona de Mediana Edad , Masculino , Foramen Oval Permeable/diagnóstico , Foramen Oval Permeable/cirugía , Foramen Oval Permeable/complicaciones , Resultado del Tratamiento , Ecocardiografía , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Dispositivo Oclusor Septal/efectos adversos , Tromboembolia/etiología , Cateterismo Cardíaco/métodos
14.
Eur J Pediatr ; 183(5): 2193-2201, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38381375

RESUMEN

Transcatheter patent ductus arteriosus (PDA) closure is a safe and effective alternative to surgical ligation in low-body-weight infants. Post-ligation cardiac syndrome (PLCS) is defined as severe hemodynamic and respiratory collapse within 24 h of PDA closure, requiring initiation or an increase of an inotropic agent by > 20% of preligation dosing and an absolute increase of at least 20% in ventilation parameters compared with the preoperative value. Whilst PLCS is routinely observed after surgery, its incidence remains poorly described following transcatheter closure. This study aimed to compare the incidence of PLCS after surgical versus transcatheter closure of PDA in low-body-weight premature infants. Propensity scores were used to compare surgical (N = 78) and transcatheter (N = 76) groups of preterm infants who underwent PDA closure at a procedural weight less than 2000 g in two tertiary institutions between 2009 and 2021. The primary outcome was the incidence of PLCS. Secondary outcomes included overall mortality before discharge, risk factors for PLCS, and post-procedural complications. Procedural success was 100% in both groups. After matching, transcatheter group experienced no PLCS vs 15% in the surgical group (p = 0.012). Furthermore, overall mortality (2% vs 17%; p = 0.03) and major complications (2% vs 23%; p = 0.002) were higher in the surgical group. Surgery (100% vs 47%; p < 0.01), gestation age (25 ± 1 vs 26 ± 2 weeks, p < 0.05) and inotropic support before closure (90% vs 29%; p < 0.001) were associated with PLCS occurrence.          Conclusion: Transcatheter PDA closure may be equally effective but safer than surgical PDA closure in low-body-weight premature infants. What is Known: • Post-ligation cardiac syndrome is a serious and common complication of surgical closure of the ductus arteriosus in preterm infants. • Transcatheter closure of preterm ductus arteriosus is a safe and effective technique that is becoming more and more common worldwide. What is New: • Device closure is safer than surgical ligation for patent ductus arteriosus closure in preterm infants and may be the first-line non-pharmacological therapeutic option in this indication in experienced teams. • Our findings should encourage neonatologists and pediatric cardiologists to start and/or strengthen a durable interventional program for transcatheter PDA closure in premature infants.


Asunto(s)
Cateterismo Cardíaco , Conducto Arterioso Permeable , Recien Nacido Prematuro , Complicaciones Posoperatorias , Humanos , Conducto Arterioso Permeable/cirugía , Estudios Retrospectivos , Recién Nacido , Femenino , Ligadura/métodos , Ligadura/efectos adversos , Masculino , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efectos adversos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Recién Nacido de Bajo Peso , Incidencia , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/métodos , Síndrome , Puntaje de Propensión , Dispositivo Oclusor Septal , Factores de Riesgo , Enfermedades del Prematuro/cirugía , Enfermedades del Prematuro/etiología , Enfermedades del Prematuro/terapia , Enfermedades del Prematuro/epidemiología
15.
Heart Vessels ; 39(6): 539-548, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38329512

RESUMEN

For pre-procedural planning of left atrial appendage (LAA) closure, sizing is crucial. Although transesophageal echocardiography (TEE) is a standard modality, cardiac computed tomography (CT) is also widely used. The virtual TEE (V-TEE) that our group developed enables us to reconstruct images similar to TEE images from CT images. The software should be helpful to understand and plan the procedure strategy. Accordingly, we investigated the utility of V-TEE. Sixty-six patients at 4 participating sites who completed both CT and TEE prior to LAA closure were included. The LAA diameter at the landing zone (LZ) for WATCHMAN™ device implantation was statistically compared at 0°, 45°, 90°, and 135° between V-TEE and TEE. Among 66 cases, only 3 cases were excluded due to poor imaging quality, and 63 cases were analyzed. The device LZ diameters based on V-TEE were strongly correlated with those based on TEE, despite the significantly greater diameter based on V-TEE with mean differences of 2.4 to 3.0 mm (all of them: P < 0.001). The discordances (V-TEE/TEE ratio) at most angles were significantly larger in the elliptical LAAs. V-TEE provides a valuable method for the evaluation of the LAA diameters. V-TEE-based measurements were larger than conventional TEE-based measurements, especially in cases of elliptical LAAs. The assessment by V-TEE has the potential benefit of ensuring proper device sizing regardless of the LAA morphology.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ecocardiografía Transesofágica , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Ecocardiografía Transesofágica/métodos , Femenino , Masculino , Anciano , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Tomografía Computarizada por Rayos X/métodos , Anciano de 80 o más Años , Estudios Retrospectivos , Cateterismo Cardíaco/métodos , Dispositivo Oclusor Septal , Persona de Mediana Edad , Tomografía Computarizada Multidetector/métodos , Reproducibilidad de los Resultados
17.
BMJ Case Rep ; 17(2)2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38331445

RESUMEN

A South Asian male in his early 60s presented with acute-onset dyspnoea on postoperative day 4 after undergoing middle hepatic vein sacrificing partial liver resection for epithelioid angiomyolipoma. The patient's SpO2 on presentation was 65% in standing position which improved to 90% in left lateral decubitus. He was suspected of having platypnea-orthodeoxia syndrome (POS) which was confirmed on echocardiogram with microbubble contrast showing a large intracardiac right-to-left shunt. The patient was taken up for transcatheter closure of patent foramen ovale (PFO). A 30 mm Amplatzer PFO Occluder was deployed across the PFO which reduced the intracardiac shunt resulting in an improved arterial saturation as well as immediate relief of patient's symptoms. This case illustrates the importance of suspecting and recognising POS clinically as well as the efficacy of transcatheter closure of PFO in such cases leading to resolution of hypoxaemia in a short span of time.


Asunto(s)
Foramen Oval Permeable , Dispositivo Oclusor Septal , Humanos , Masculino , Persona de Mediana Edad , Disnea/diagnóstico , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/diagnóstico por imagen , Foramen Oval Permeable/cirugía , Hipoxia/etiología , Hipoxia/terapia , Hipoxia/diagnóstico , Hígado , Síndrome de Platipnea Ortodesoxia
18.
Cardiovasc Interv Ther ; 39(2): 200-206, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38265606

RESUMEN

Transcatheter closure of patent foramen ovale (PFO) is an effective strategy for preventing recurrence of paradoxical embolism. However, PFO closure is often associated with residual shunt, which is a risk of recurrent stroke. This study aimed to evaluate the relationship between the anatomical features of PFO and residual shunt. The degree of residual shunt and its relationship with the anatomical features of PFO were evaluated in 106 patients who underwent PFO closure at our institution between March 2011 and January 2022 and in whom contrast transthoracic echocardiography was performed 1 year later. The mean PFO tunnel length was 9.3 ± 3.6 mm and the mean PFO height was 3.2 ± 2.2 mm. Atrial septal aneurysm (ASA) was found in 37 patients. After PFO closure, residual shunt was observed in 28 patients (grade 1, n = 8; grade 2, n = 16; grade 3, n = 3; grade 4, n = 1). Univariate logistic analysis identified ASA to be associated with residual shunt (odds ratio 2.78, 95% confidence interval 1.14 to 6.79; p = 0.024). There was no association of residual shunt with the size of the PFO, the length of PFO tunnel, or the size of the device used for closure. Two of four patients with a large residual shunt of grade 3 or grade 4 were found to have device size mismatch. Residual shunt after PFO closure was observed in a quarter of patients and was related to the presence of ASA. A few patients had a large residual shunt due to the device size mismatch.


Asunto(s)
Foramen Oval Permeable , Dispositivo Oclusor Septal , Accidente Cerebrovascular , Humanos , Foramen Oval Permeable/cirugía , Foramen Oval Permeable/complicaciones , Ecocardiografía , Resultado del Tratamiento , Cateterismo Cardíaco
19.
Ann Cardiol Angeiol (Paris) ; 73(2): 101718, 2024 Apr.
Artículo en Francés | MEDLINE | ID: mdl-38262253

RESUMEN

INTRODUCTION: Post-infarction ventricular septal defect (PIVSD) is one of the most serious mechanical complications of acute myocardial infarction (AMI). Over the last decade, percutaneous closure is increasingly undertaken, with results similar to cardiac surgery. We present a case of ST-elevated anterior AMI, complicated by apical PIVSD successfully treated with transcatheter closure. CASE REPORT: An 83-year-old man was hospitalized for chest pain occurred 18 hours before, during the night time. He was an active smoker. Clinical examination revealed normal heart sounds and pulmonary bibasilar crackles. ST-segment elevation with deep T waves inversion in anterior leads were detected on the electrocardiogram. A mildly-reduced ejection fraction (40%) was found by transthoracic echocardiogram. The patient underwent emergency coronary angiography, which revealed a subocclusive stenosis of the mid left anterior descending artery with a TIMI 2 flow, treated by balloon angioplasty and drug-eluting stent. Four days after revascularization, the patient developed an acute deterioration with signs of decompensated heart failure and a new holosystolic murmur with large irradiation. Inotropic agents' administration was required to maintain a precarious hemodynamic condition. A bedside Echo revealed an apical VSD, measuring 15 × 10 mm, with left-to-right shunting, and pulmonary hypertension. The patient was scheduled for transcatheter PIVSD closure. The procedure was performed under fluoroscopic guide. Two vascular access sites were placed, femoral arterial and right internal jugular vein. Through the right internal jugular vein, a 24-mm Amplatzer atrial septal occluder on a 9 French Amplatzer TREVISIO™ intravascular delivery system was advanced via right ventricle into the PIVSD. Contrast fluoroscopy was used to assess apposition and the degree of shunt reduction before release. Echocardiographic evaluation performed 48 hours later confirmed a correct apposition of the device with insignificant residual shunt. At 6 months follow-up, he was asymptomatic, with unchanged prosthetic findings. CONCLUSION: Percutaneous closure has been emerged as a valid cost-effective alternative to surgery and should be advised. However, debate remains on the optimal preprocedural optimization, timing of repair and modality of treatment.


Asunto(s)
Infarto de la Pared Anterior del Miocardio , Procedimientos Quirúrgicos Cardíacos , Stents Liberadores de Fármacos , Defectos del Tabique Interventricular , Infarto del Miocardio , Infarto del Miocardio con Elevación del ST , Dispositivo Oclusor Septal , Masculino , Humanos , Anciano de 80 o más Años , Resultado del Tratamiento , Stents Liberadores de Fármacos/efectos adversos , Cateterismo Cardíaco/métodos , Infarto del Miocardio/complicaciones , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Dispositivo Oclusor Septal/efectos adversos , Infarto de la Pared Anterior del Miocardio/complicaciones , Defectos del Tabique Interventricular/complicaciones , Defectos del Tabique Interventricular/diagnóstico , Defectos del Tabique Interventricular/cirugía , Infarto del Miocardio con Elevación del ST/cirugía , Infarto del Miocardio con Elevación del ST/complicaciones
20.
J Vet Cardiol ; 51: 214-219, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38232623

RESUMEN

A 16-month-old Labrador-Poodle cross (case 1) and a 3-month-old German shorthaired pointer (case 2) were referred for patent ductus arteriosus (PDA) occlusion. Two-dimensional transthoracic and two- and three-dimensional transesophageal echocardiography revealed a window-like PDA characterized by a wide and short ductus. Due to the atypical PDA morphology with no ampulla in case 1, ductal occlusion was attempted with non-canine-specific Amplatzer occluder devices. However, these were too small and failed to remain stable. Amplatz Canine Duct Occluder (ACDO) devices were used with success in both cases. Due to the defects' morphology, the proximal ACDO disc protruded into the aorta but there were no signs of obstruction to aortic blood flow 16 months (case 1) and 1 month (case 2) post-occlusion. We describe two cases of a window-like type PDA that were successfully occluded with an ACDO.


Asunto(s)
Enfermedades de los Perros , Conducto Arterioso Permeable , Dispositivo Oclusor Septal , Perros , Animales , Conducto Arterioso Permeable/diagnóstico por imagen , Conducto Arterioso Permeable/cirugía , Conducto Arterioso Permeable/veterinaria , Ecocardiografía Transesofágica/veterinaria , Enfermedades de los Perros/diagnóstico por imagen , Enfermedades de los Perros/cirugía , Dispositivo Oclusor Septal/veterinaria , Cateterismo Cardíaco/veterinaria , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...