Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 278
Filtrar
1.
Cardiovasc Ultrasound ; 19(1): 9, 2021 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-33472662

RESUMEN

PURPOSE: This study was a quality-control study of resting and exercise Doppler echocardiography (EDE) variables measured by 19 echocardiography laboratories with proven experience participating in the RIGHT Heart International NETwork. METHODS: All participating investigators reported the requested variables from ten randomly selected exercise stress tests. Intraclass correlation coefficients (ICC) were calculated to evaluate the inter-observer agreement with the core laboratory. Inter-observer variability of resting and peak exercise tricuspid regurgitation velocity (TRV), right ventricular outflow tract acceleration time (RVOT Act), tricuspid annular plane systolic excursion (TAPSE), tissue Doppler tricuspid lateral annular systolic velocity (S'), right ventricular fractional area change (RV FAC), left ventricular outflow tract velocity time integral (LVOT VTI), mitral inflow pulsed wave Doppler velocity (E), diastolic mitral annular velocity by TDI (e') and left ventricular ejection fraction (LVEF) were measured. RESULTS: The accuracy of 19 investigators for all variables ranged from 99.7 to 100%. ICC was > 0.90 for all observers. Inter-observer variability for resting and exercise variables was for TRV = 3.8 to 2.4%, E = 5.7 to 8.3%, e' = 6 to 6.5%, RVOT Act = 9.7 to 12, LVOT VTI = 7.4 to 9.6%, S' = 2.9 to 2.9% and TAPSE = 5.3 to 8%. Moderate inter-observer variability was found for resting and peak exercise RV FAC (15 to 16%). LVEF revealed lower resting and peak exercise variability of 7.6 and 9%. CONCLUSIONS: When performed in expert centers EDE is a reproducible tool for the assessment of the right heart and the pulmonary circulation.


Asunto(s)
Ecocardiografía Doppler/normas , Ventrículos Cardíacos/diagnóstico por imagen , Circulación Pulmonar/fisiología , Volumen Sistólico/fisiología , Disfunción Ventricular Derecha/diagnóstico , Función Ventricular Derecha/fisiología , Anciano , Prueba de Esfuerzo , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Curva ROC , Sístole , Disfunción Ventricular Derecha/fisiopatología , Función Ventricular Izquierda/fisiología
2.
Crit Care Med ; 48(10): e943-e950, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32885942

RESUMEN

OBJECTIVES: Evaluation of left atrial pressure is frequently required for mechanically ventilated critically ill patients. The objective of the present study was to evaluate the 2016 American Society of Echocardiography and the European Association of Cardiovascular Imaging guidelines for assessment of the pulmonary artery occlusion pressure (a frequent surrogate of left atrial pressure) in this population. DESIGN: A pooled analysis of three prospective cohorts of patients simultaneously assessed with a pulmonary artery catheter and echocardiography. SETTINGS: Medical-surgical intensive care department of two university hospitals in France. PATIENTS: Mechanically ventilated critically ill patients. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Of 98 included patients (males: 67%; mean ± SD age: 59 ± 16; and mean Simplified Acute Physiology Score 2: 54 ± 20), 53 (54%) experienced septic shock. Using the 2016 American Society of Echocardiography and the European Association of Cardiovascular Imaging guidelines, the predicted pulmonary artery occlusion pressure was indeterminate in 48 of the 98 patients (49%). Of the 24 patients with an elevated predicted left atrial pressure (grade II/III diastolic dysfunction), only 17 (71%) had a pulmonary artery occlusion pressure greater than or equal to 18 mm Hg. Similarly, 20 of the 26 patients (77%) with a normal predicted left atrial pressure (grade I diastolic dysfunction) had a measured pulmonary artery occlusion pressure less than 18 mm Hg. The sensitivity and specificity of American Society of Echocardiography and the European Association of Cardiovascular Imaging guidelines for predicting elevated pulmonary artery occlusion pressure were both 74%. The agreement between echocardiography and the pulmonary artery catheter was moderate (Cohen's Kappa, 0.48; 95% CI, 0.39-0.70). In a proposed alternative algorithm, the best echocardiographic predictors of a normal pulmonary artery occlusion pressure were a lateral e'-wave greater than 8 (for a left ventricular ejection fraction ≥ 45%) or an E/A ratio less than or equal to 1.5 (for a left ventricular ejection fraction < 45%). CONCLUSIONS: The American Society of Echocardiography and the European Association of Cardiovascular Imaging guidelines do not accurately assess pulmonary artery occlusion pressure in ventilated critically ill patients. Simple Doppler measurements gave a similar level of diagnostic performance with less uncertainly.


Asunto(s)
Presión Arterial/fisiología , Aterosclerosis/patología , Determinación de la Presión Sanguínea/métodos , Ecocardiografía Doppler/métodos , Arteria Pulmonar/patología , Respiración Artificial , Adulto , Anciano , Determinación de la Presión Sanguínea/normas , Enfermedad Crítica , Ecocardiografía Doppler/normas , Femenino , Hospitales Universitarios , Humanos , Unidades de Cuidados Intensivos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad
4.
Rev Port Cardiol (Engl Ed) ; 39(1): 47.e1-47.e5, 2020 Jan.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-32173092

RESUMEN

Pulmonary embolism due to primary antiphospholipid syndrome is rarely associated with chronic thromboembolic pulmonary hypertension, and therefore according to the latest guidelines on pulmonary hypertension, routine screening is not recommended. We describe a young patient with a late diagnosis of chronic thromboembolic pulmonary hypertension in the context of pulmonary embolism, primary antiphospholipid syndrome and suboptimal anticoagulation. Of note, mild cardiopulmonary symptoms were consistently misattributed to a depressive disorder because physical examination was normal, serial Doppler echocardiography failed to show pulmonary hypertension, and all other diagnostic tests were normal. Once symptoms became severe, positive screening tests led to the correct diagnosis and surgical referral, and bilateral pulmonary endarterectomy was successfully performed. This case demonstrates the need for extra awareness in patients with antiphospholipid syndrome and pulmonary embolism.


Asunto(s)
Síndrome Antifosfolípido/complicaciones , Disnea/etiología , Hipertensión Pulmonar/diagnóstico , Embolia Pulmonar/complicaciones , Adulto , Concienciación , Enfermedad Crónica , Trastorno Depresivo/diagnóstico , Ecocardiografía Doppler/efectos adversos , Ecocardiografía Doppler/normas , Endarterectomía/métodos , Femenino , Humanos , Embolia Pulmonar/cirugía , Resultado del Tratamiento
5.
BMC Cardiovasc Disord ; 20(1): 8, 2020 01 09.
Artículo en Inglés | MEDLINE | ID: mdl-31918676

RESUMEN

BACKGROUND: Ischemic cardiomyopathy is a high-cost, resource-intensive public health burden that is associated with a 1-year mortality rate of about 16% in western population. Different in patient ethnicity and pattern of practice may impact the clinical outcome. We aim to determine 1-year mortality and to identify factors that significantly predicts 1-year mortality of Thai patients with ischemic cardiomyopathy. METHODS: This prospective multicenter registry enrolled consecutive Thai patients that were diagnosed with ischemic cardiomyopathy at 9 institutions located across Thailand. Patients with left ventricular function < 40% and one of the following criteria were included: 1) presence of epicardial coronary stenoses > 75% in the left main or proximal left anterior descending artery or coronary angiography, and/or two major epicardial coronary stenoses; 2) prior myocardial infarction; 3) prior revascularization by coronary artery bypass graft or percutaneous coronary intervention; or, 4) magnetic resonance imaging pattern compatible with ischemic cardiomyopathy. Baseline clinical characteristics, coronary and echocardiographic data were recorded. The 1-year clinical outcome was pre-specified. RESULTS: Four hundred and nineteen patients were enrolled. Thirty-nine patients (9.9%) had died at 1 year, with 27 experiencing cardiovascular death, and 12 experiencing non-cardiovascular death. A comparison between patients who were alive and patients who were dead at 1 year revealed lower baseline left ventricular ejection fraction (LVEF) (26.7 ± 7.6% vs 30.2 ± 7.8%; p = 0.021), higher left ventricular end-diastolic volume (LVEDV) (185.8 ± 73.2 ml vs 155.6 ± 64.2 ml; p = 0.014), shorter mitral valve deceleration time (142.9 ± 57.5 ml vs 182.4 ± 85.7 ml; p = 0.041), and lower use of statins (94.7% vs 99.7%; p = 0.029) among deceased patients. Patients receiving guideline-recommended ß-blockers had lower mortality than patients receiving non-guideline-recommended ß-blockers (8.1% vs 18.2%; p = 0.05). CONCLUSIONS: The results of this study revealed a 9.9% 1-year mortality rate among Thai ischemic cardiomyopathy patients. Doppler echocardiographic parameters significantly associated with 1-year mortality were LVEF, LVEDV, mitral E velocity, and mitral valve deceleration time. The use of non-guideline-recommended ß-blockers rather than guideline recommended ß-blockers were associated with increased with 1-year mortality. Guidelines recommended ß-blockers should be preferred. TRIAL REGISTRATION: Thai Clinical Trials Registry TCTR20190722002. Registered 22 July 2019. "Retrospectively registered".


Asunto(s)
Antagonistas Adrenérgicos beta/uso terapéutico , Cardiomiopatías , Ecocardiografía Doppler/normas , Adhesión a Directriz/normas , Isquemia Miocárdica , Guías de Práctica Clínica como Asunto/normas , Pautas de la Práctica en Medicina/normas , Antagonistas Adrenérgicos beta/efectos adversos , Anciano , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/tratamiento farmacológico , Cardiomiopatías/mortalidad , Cardiomiopatías/fisiopatología , Causas de Muerte , Femenino , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/tratamiento farmacológico , Isquemia Miocárdica/mortalidad , Isquemia Miocárdica/fisiopatología , Valor Predictivo de las Pruebas , Estudios Prospectivos , Sistema de Registros , Factores de Riesgo , Volumen Sistólico/efectos de los fármacos , Tailandia , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda/efectos de los fármacos
6.
J Matern Fetal Neonatal Med ; 33(14): 2348-2353, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30541361

RESUMEN

Introduction: Fetal heart rate monitoring presents one of the few available methods for evaluating the fetus prior to birth. However, current devices on the market have significant shortcomings. We sought to describe the use and experiences with external fetal monitoring (EFM) devices among obstetrical providers.Materials and methods: We performed a cross-sectional survey in an academic medical center between April and July 2017 including nurse, midwife, and physician obstetrical providers (n = 217) who were invited to participate in this study regarding their experiences with the external fetal monitoring (EFM) device utilized by their hospital system in the outpatient, inpatient, and labor and delivery (L&D) settings. Associations between provider characteristics, device use, perception of challenging patients, and potential usefulness of an improved system were assessed by Fisher's exact test.Results: The 137 respondents (63.1%) reported difficulties monitoring obese women (98.5%), multiple gestation pregnancies (90.5%), and early gestational ages (71.5%). Over half (59.5%) of L&D nurses reported interacting with EFM devices for greater than 1-hour during a typical 12-hour shift and fewer than half (42.3%) reported being satisfied with current EFM devices. There were no statistically significant associations between provider age, experience, or time spent utilizing the devices with perception of challenging patient types.Conclusions: In conclusion, obstetrical providers perceive shortcomings of current EFM devices across all levels of provider experience and time utilizing these devices. Nurses reported significant time operating the devices, representing an opportunity to reduce time and costs with an improved device.


Asunto(s)
Actitud del Personal de Salud , Cardiotocografía/normas , Obstetricia/métodos , Centros Médicos Académicos/estadística & datos numéricos , Adulto , Cardiotocografía/instrumentación , Estudios Transversales , Ecocardiografía Doppler/métodos , Ecocardiografía Doppler/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Embarazo , Encuestas y Cuestionarios
7.
Int J Cardiovasc Imaging ; 35(12): 2157-2166, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31346831

RESUMEN

2016 guidelines for the echographic evaluation of left ventricular filling pressure (LVFP) proposed a single algorithm with limited number of criteria (E/A ratio, tricuspid regurgitation velocity, left atrial volume index and average E/e') mainly related to left atrial pressure. Pulmonary venous flow analysis, evaluating more specifically left ventricular end diastolic pressure (LVEDP) has been withdrawn. We aim to evaluate the proportion of patients diagnosed with normal LVFP according to 2016 recommendations, despite an abnormal pulmonary venous flow profile suggesting high LVEDP. We prospectively studied patients with stable ischemic cardiomyopathy and aortic stenosis, before cardiac surgery. Extensive echocardiography was performed including pulmonary and mitral A wave durations. We included 76 patients (mean age 72 ± 10 years, 78% were men), 37 (49%) with aortic stenosis and 22 (29%) with ischemic cardiomyopathy. Mean left ventricular ejection fraction was 67 ± 11%. Applying recommendations, 58 patients had normal LVFP and 15 patients had high LVFP. Among the 58 patients with normal LVFP, 26 patients had Apd-Amd duration > 30 ms highly suggestive of high LVEDP. These patients had higher LV mass (112 ± 30 g/m2 vs. 86 ± 20 g/m2, p = 0.004) and shorter A wave duration (120 ± 13.6 ms vs. 132 ± 16.5 ms, p = 0.006) as compared to the remaining 15 patients with concordant evaluation (normal LVFP and normal Apd-Amd). In the present study, we found that 26/58 patients with low LVFP according to the 2016 recommendations had Apd-Amd suggestive of high LVEDP. Pulmonary venous flow should be added to the algorithm, particularly in patients with unexplained symptom, high LV mass or truncated mitral A wave.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Cardiomiopatías/diagnóstico por imagen , Ecocardiografía Doppler/normas , Adhesión a Directriz/normas , Guías de Práctica Clínica como Asunto/normas , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda , Presión Ventricular , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/fisiopatología , Cardiomiopatías/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Disfunción Ventricular Izquierda/fisiopatología
8.
Adv Med Sci ; 64(2): 309-314, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30974403

RESUMEN

PURPOSE: Pulmonary hypertension (PH) is an ominous complication in systemic sclerosis patients (SSc) and echocardiography is a screening tool for its detection. The goal of this study was to assess the reliability of resting and exercise echo Doppler parameters with data obtained by right heart catheterization (RHC). MATERIAL AND METHODS: We included 91 patients (84 F, 53.3 ± 15.2 years) with SSc. Transthoracic echocardiography followed by exercise Doppler-echocardiography (EDE) were performed. A positive EDE was defined as a ≥20 mmHg increase in tricuspid regurgitation peak gradient (TRPG). RHC with exercise was performed in positive EDE patients and/or in subjects with resting TRPG > 31 mmHg. RESULTS: Finally, RHC was performed in 20 patients. The correlation for the echocardiography and invasive measurement of systolic (sPAP) and mean (mPAP) pulmonary artery pressure was r = 0.66 (p = 0.001) and r = 0.7 (p = 0.001), respectively. We also found significant correlation between echocardiography and invasive measurement of exercise sPAP r = 0.68 (p = 0.001) and exercise mPAP r = 0.67 (p = 0.002). There was a correlation between pulmonary vascular resistance (PVR) assessed by echocardiography and measured by RHC r = 0.49, p = 0.027. The equation derived within our population was: PVR by echocardiography = 9.6*TRV/TVIRVOT+0.068. We also performed ROC analysis to predict PVR > 2 WU. Our results highlight that sPAP has the highest AUC (0.802, 95% CI 0.585-1). CONCLUSION: Doppler resting and exercise echocardiography may provide a reliable, noninvasive method for determining resting and exercise sPAP, mPAP, and PVR in SSc patients, although it may underestimate or overestimate these values in some individuals. Doppler echocardiography does not replace RHC for definite hemodynamic assessment of suspected PH.


Asunto(s)
Ecocardiografía Doppler/normas , Hemodinámica/fisiología , Circulación Pulmonar/fisiología , Esclerodermia Sistémica/fisiopatología , Adulto , Anciano , Femenino , Humanos , Hipertensión Pulmonar/diagnóstico , Hipertensión Pulmonar/fisiopatología , Masculino , Persona de Mediana Edad , Esclerodermia Sistémica/diagnóstico
9.
Int J Cardiovasc Imaging ; 35(6): 991-998, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30891666

RESUMEN

Left atrial (LA) size and function have been demonstrated to be important imaging biomarkers with powerful potential in predicting clinical outcome in several disorders. The angle-independent three-dimensional (3D) speckle-tracking echocardiography (3DSTE) has a capability for quantitative assessment of LA volumes and strains in 3D space at the same time from the same 3D acquired datasets. Therefore, the objective of the present study was to define normal values of 3DSTE-derived LA strains in healthy subjects. It was also examined whether there is any age- and gender-dependency of these parameters. The present study comprised 309 healthy volunteers, from which 87 were excluded due to inadequate image quality. The remaining group consisted of 222 subjects (mean age: 36.3 ± 13.7 years, 112 males). Complete two-dimensional echocardiography and 3DSTE have been performed in all cases. Peak circumferential strain (CS) increased with age with a decline > 50 years in females, in males CS remained almost unchanged. While peak longitudinal strain (LS) increased with age with unchanged parameters > 50 years, parallel increase in peak area strain (AS) with age could be demonstrated in both genders with a decline in females > 50 years. While CS and AS at atrial contraction increased with age in females, parallel decrease could be demonstrated in males. LS at atrial contraction increased with age especially in females. Normal values of 3DSTE-derived LA peak strains and strains at atrial contraction are demonstrated together with their age- and gender-dependency.


Asunto(s)
Función del Atrio Izquierdo , Ecocardiografía Doppler , Ecocardiografía Tridimensional , Atrios Cardíacos/diagnóstico por imagen , Adolescente , Adulto , Factores de Edad , Ecocardiografía Doppler/normas , Ecocardiografía Tridimensional/normas , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Valores de Referencia , Factores Sexuales , Adulto Joven
10.
Int J Cardiol ; 291: 112-118, 2019 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-30851993

RESUMEN

BACKGROUND: The World Heart Federation (WHF) criteria, published in 2012, provided an evidence-based guideline for the minimal diagnosis of echocardiographically-detected RHD. Primary aim of the study was to determine whether use of the WHF criteria altered the threshold for the diagnosis of echocardiographically-detected RHD compared with the previous WHO/NIH criteria. A secondary aim was to explore the utility of a three reviewer reporting system compared to a single or two reviewer reporting structure. METHODS: 144 de-identified echocardiograms (RHD, congenital valvar abnormality, physiological valvar regurgitation) were independently reported using the WHF criteria by two reviewers blinded to the previous WHO/NIH diagnosis. If there was discordance between the two reviewers, a third cardiologist independently performed a tie-breaker review. RESULTS: There was a 21% reduction of cases classified as RHD using the WHF criteria compared to the modified WHO/NIH criteria (68 cases compared to 86, p = 0.04). There was a 60% consensus across the different diagnostic categories with 2 reviewers, 89% majority agreement with 3 reviewers. 11% required an open label discussion. There was moderate agreement between 2 reviewers for any RHD, kappa 0.57 (CI 0.44-0.70), with no significant difference in agreement between the different categories. CONCLUSION: The WHF criteria have raised the threshold for the diagnosis of RHD compared to the WHO/NIH criteria. However, inter-reporter variability of the WHF criteria is high. A three reviewer system is likely more accurate than a single or two reporter system for the diagnosis of mild RHD. This has resource implications for echocardiographic screening programmes.


Asunto(s)
Cardiólogos/normas , Ecocardiografía Doppler/normas , Tamizaje Masivo/normas , Cardiopatía Reumática/diagnóstico por imagen , Cardiopatía Reumática/epidemiología , Adolescente , Niño , Femenino , Humanos , Masculino , Tamizaje Masivo/clasificación , Tamizaje Masivo/métodos , Nueva Zelanda/epidemiología , Cardiopatía Reumática/clasificación
12.
Circ Cardiovasc Imaging ; 12(1): e008122, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-30632389

RESUMEN

BACKGROUND: Assessment of left ventricular (LV) filling pressure is among the important components of a comprehensive echocardiographic report. Previous studies noted wide limits of agreement using 2009 American Society of Echocardiography/European Association of Echocardiography guidelines, but reproducibility of 2016 guidelines update in estimating LV filling pressure is unknown. METHODS: Echocardiographic and hemodynamic data were obtained from 50 patients undergoing cardiac catheterization for clinical indications. Clinical and echocardiographic findings but not invasive hemodynamics were provided to 4 groups of observers, including experienced echocardiographers and cardiology fellows. Invasively acquired LV filling pressure was the gold standard. RESULTS: In group I of 8 experienced echocardiographers from the guidelines writing committee, sensitivity for elevated LV filling pressure was 92% for all observers, and specificity was 93±6%. Fleiss κ-value for the agreement in group I was 0.80. In group II of 4 fellows in training, sensitivity was 91±2%, and specificity was 95±2%. Fleiss κ-value for the agreement in group II was 0.94. In group III of 9 experienced echocardiographers who had not participated in drafting the guidelines, sensitivity was 88±5%, and specificity was 91±7%. Fleiss κ-value for the agreement in group III was 0.76. In group IV of 7 other fellows, sensitivity was 91±3%, and specificity was 92±5%. Fleiss κ-value for the agreement in group IV was 0.89. CONCLUSIONS: There is a good level of agreement and accuracy in the estimation of LV filling pressure using the American Society of Echocardiography/European Association of Cardiovascular Imaging 2016 recommendations update, irrespective of the experience level of the observer.


Asunto(s)
Ecocardiografía Doppler/normas , Cardiopatías/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Guías de Práctica Clínica como Asunto/normas , Función Ventricular Izquierda , Presión Ventricular , Anciano , Femenino , Cardiopatías/fisiopatología , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
13.
Int J Cardiovasc Imaging ; 35(5): 861-868, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30666551

RESUMEN

Echocardiographic assessment of diastolic dysfunction depends on surrogate parameters. In recent years, guideline committees attempted to combine these parameters to diagnostic flowcharts allowing for correct classification of left ventricular filling pressures (LVFP). The value of these diagnostic tools is limited if the applied surrogate parameters are elevated due to other reasons as is the case with maximal tricuspid regurgitation velocity. We aimed to compare the accuracy of the 2009 and the 2016 guideline recommendations in patients with pulmonary hypertension (PH). We included 101 consecutive patients who underwent right heart catheterization and transthoracic echocardiography for suspicion of PH. For the final analysis, only patients with PH were considered. The 2009 and 2016 recommendations for the assessment of diastolic function by echocardiography were applied on each patient. A total of 63 PH patients were included in the final analysis, 43% had elevated LVFP. By using the 2009 recommendations, sensitivity for correct classification of diastolic dysfunction was 67%, specificity was 82%, area under the curve (AUC) was 0.74. By using the 2016 recommendations, sensitivity for correct classification of diastolic dysfunction was 84%, specificity was 80%, AUC was 0.82. In ROC comparison, the AUC for the 2016 recommendations with 0.82 was significantly better compared to the AUC of 0.74 for the 2009 recommendations (p = 0.04). Our study demonstrates that the 2016 recommendations for echocardiographic evaluation of diastolic function are superior to the 2009 recommendations in estimating left ventricular filling pressures in patients with PH.


Asunto(s)
Ecocardiografía Doppler , Hipertensión Pulmonar/diagnóstico por imagen , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda , Presión Ventricular , Adulto , Anciano , Anciano de 80 o más Años , Cateterismo de Swan-Ganz , Diástole , Ecocardiografía Doppler/normas , Femenino , Humanos , Hipertensión Pulmonar/fisiopatología , Masculino , Persona de Mediana Edad , Guías de Práctica Clínica como Asunto , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Disfunción Ventricular Izquierda/fisiopatología , Adulto Joven
14.
Int J Cardiovasc Imaging ; 35(2): 259-265, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30269294

RESUMEN

Several models have been used to establish pediatric Z-scores for echocardiographic right ventricle (RV) variables. This study aimed to determine the most appropriate mathematical model for RV function reference values in pediatrics. Prospective cross-sectional study among 314 healthy children ages 2 days to 18 years (46% female, 88 infants, 26 neonates, 226 children). RV parameters (S', E', A' waves, TEI index, TAPSE) were modelized with four explanatory variables: age, height, weight and body surface area. Four mathematical models were applied: a linear model, a polynomial model of degree 2, a linear regression model by spline with free knot, and a polynomial regression model of degree 2 by spline with a free knot. The choice of the best method used the adjusted coefficient of determination (aR2). The modelization of RV variables did not follow a linear model. A single explanatory variable could not determine all Z-scores, as specific and independent variables were required for each parameter. The quadratic spline model best adjusted the modelization of RV variables. The S' wave was best modelized by the spline model with the weight (knot at 6.86 kg). The E' wave was best modelized by the spline model with the age (knot at 0.29 years). The A' wave was best modelized by the model with the height (knot at 81 cm). The TAPSE was best modelized by the spline model with the weight (knot at 9.04 kg). The spline regression models best applies to echocardiographic RV reference values in pediatrics.


Asunto(s)
Ecocardiografía Doppler/normas , Ventrículos Cardíacos/diagnóstico por imagen , Función Ventricular Derecha , Adolescente , Factores de Edad , Niño , Preescolar , Estudios Transversales , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Modelos Cardiovasculares , Valor Predictivo de las Pruebas , Estudios Prospectivos , Estándares de Referencia , Reproducibilidad de los Resultados
16.
J Cardiovasc Med (Hagerstown) ; 19(10): 527-535, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30015781

RESUMEN

: Clinical presentation, diagnosis and outcomes of cardiac diseases are influenced by the activity of sex steroid hormones. These hormonal differences explain the later development of heart diseases in women in comparison with men and the different clinical picture, management and prognosis. Echocardiography is a noninvasive and easily available technique for the analysis of cardiac structure and function. The aim of the present review is to underline the most important echocardiographic differences between sexes. Several echocardiographic studies have found differences in healthy populations between women and men. Sex-specific difference of some of these parameters, such as left ventricular (LV) linear dimensions and left atrial volume, can be explained on the grounds of smaller body size of women, but other parameters (LV volumes, stroke volume and ejection fraction, right ventricular size and systolic function) are specifically lower in women, even after adjusting for body size and age. Sex-specific differences of standard Doppler and Tissue Doppler diastolic indices remain controversial, but it is likely for aging to affect LV diastolic function more in women than in men. Global longitudinal strain appears to be higher in women during the childbearing age - a finding that also highlights a possible hormonal influence in women. All these findings have practical implications, and sex-specific reference values are necessary for the majority of echocardiographic parameters in order to distinguish normalcy from disease. Careful attention on specific cut-off points in women could avoid misinterpretation, inappropriate management and delayed treatment of cardiac diseases such as valvular disease and heart failure.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico por imagen , Ecocardiografía Doppler/normas , Ecocardiografía Tridimensional/normas , Ventrículos Cardíacos/diagnóstico por imagen , Contracción Miocárdica , Volumen Sistólico , Función Ventricular Izquierda , Salud de la Mujer , Adulto , Factores de Edad , Enfermedades Cardiovasculares/fisiopatología , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Valores de Referencia , Factores Sexuales , Adulto Joven
18.
Indian Heart J ; 70(2): 316-318, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29716713

RESUMEN

In this retrospective study 420 echocardiograms from a single center were reviewed showing that TAPSE was acquired in 66% while TA TDI s' signals were recorded in 98% of all echocardiograms. Based on these results greater efforts are required to standardize acquisition and reporting of objective measurements of RV function.


Asunto(s)
Ecocardiografía Doppler/normas , Guías de Práctica Clínica como Asunto , Válvula Tricúspide/diagnóstico por imagen , Disfunción Ventricular Derecha/diagnóstico , Función Ventricular Derecha/fisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Retrospectivos , Válvula Tricúspide/fisiopatología , Disfunción Ventricular Derecha/fisiopatología
19.
Medicine (Baltimore) ; 97(20): e10723, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29768341

RESUMEN

Research is ongoing to find a noninvasive method of monitoring, which can predict fluid responsiveness in patients undergoing kidney transplantation.To compare the responses to fluid challenges with the Pleth Variability Index, a noninvasive dynamic index derived from plethysmographic variability (Radical 7 pulse oximeter; Masimo Corporation, Irvine, CA), and the esophageal Doppler, the criterion standard.Observational study.University hospital; study from May 2011 and May 2012.Forty-eight patients with end-renal function were included and 44 analyzed. Patients with cardiac failure were not eligible.Fluid challenges were administered during maintenance of general anesthesia but before skin incision and repeated if the patient was deemed to be a "responder" (increase in stroke volume ≥10%).The primary endpoint was to assess if the Pleth Variability Index is an accurate predictor of fluid responsiveness.Among 76 fluid challenges, 38 were considered as positive (increase in stroke volume measured by Doppler ≥10%). Pleth Variability Index was similar at baseline between responders and nonresponder patients. Fluid challenges were associated with a significant decrease in Pleth Variability Index in overall cases (12 [8-14] vs 10 [6-17], P = .050), but it was not able to discriminate between responders (12 [8-15] vs 10 [5-15], P = .650) and nonresponders (11 [6-16] vs 8 [5-14], P = .047). The area under the Receiver Operating Characteristic curve for Pleth Variability Index was 0.49 (0.36-0.62).Pleth Variability Index is not an accurate predictor of fluid responsiveness during kidney transplantation.


Asunto(s)
Ecocardiografía Doppler , Fluidoterapia/métodos , Fallo Renal Crónico/cirugía , Trasplante de Riñón/métodos , Monitoreo Intraoperatorio/métodos , Pletismografía/métodos , Volumen Sistólico/fisiología , Ecocardiografía Doppler/métodos , Ecocardiografía Doppler/normas , Ecocardiografía Transesofágica/métodos , Ecocardiografía Transesofágica/normas , Femenino , Hemodinámica/fisiología , Humanos , Fallo Renal Crónico/fisiopatología , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio/normas , Oximetría/métodos , Pletismografía/normas , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
20.
Rev Chil Pediatr ; 89(1): 79-85, 2018 Feb.
Artículo en Inglés, Español | MEDLINE | ID: mdl-29664507

RESUMEN

INTRODUCTION: The echocardiographic evaluation of patients after heart transplantation is a useful tool. However, it is still necessary to define an optimal follow-up protocol. OBJECTIVE: To describe the results of the application of a functional echocardiographic protocol in patients being followed after pediatric heart transplantation. PATIENTS AND METHOD: Alls patients being followed at our institution after pediatric heart transplantation underwent an echocardiographic examination with a functional protocol that included global longitudinal strain. Contemporaneous endomyocardial biopsy results and hemodynamic data were recorded. RESULTS: 9 patients were evaluated with our echocardiographic functional protocol. Of these patients, only 1 showed systolic left ventricular dysfunction according to classic parameters. However, almost all patients had an abnormal global longitudinal strain. Right ventricular systolic dysfunction was observed in all patients. No epidodes of moderate to severe rejectiom were recorded. No correlation was observed between these parameters and pulmonary artery pressure. CONCLUSIONS: Subclinical biventricular systolic dysfunction was observed in the majority of the patients in this study. No association with rejection episodes or pulmonary hypertension was observed, which may be related to the absence of moderate or severe rejection episodes during the study period, and to the small sample size. Long term follow-up of these patients may better define the clinical relevance of our findings.


Asunto(s)
Cuidados Posteriores/métodos , Ecocardiografía Doppler/métodos , Trasplante de Corazón , Cuidados Posoperatorios/métodos , Complicaciones Posoperatorias/diagnóstico por imagen , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Derecha/diagnóstico por imagen , Adolescente , Cuidados Posteriores/normas , Niño , Preescolar , Protocolos Clínicos , Ecocardiografía Doppler/normas , Femenino , Estudios de Seguimiento , Humanos , Lactante , Recién Nacido , Masculino , Proyectos Piloto , Cuidados Posoperatorios/normas , Estudios Prospectivos , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Derecha/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...