Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 12.284
Filtrar
1.
EuroIntervention ; 20(9): 591-601, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38726722

RESUMEN

BACKGROUND: Little is known about the occurrence of subclinical new-onset atrial fibrillation (NOAF) after transcatheter aortic valve implantation (TAVI). AIMS: We aimed to evaluate the incidence, predictors, and clinical impact of subclinical NOAF after TAVI. METHODS: This was a multicentre study, including patients with aortic stenosis (AS) and no previous atrial fibrillation undergoing TAVI, with continuous ambulatory electrocardiogram (AECG) monitoring after TAVI. RESULTS: A total of 700 patients (79±8 years, 49% female, Society of Thoracic Surgeons score 2.9% [1.9-4.0]) undergoing transarterial TAVI were included (85% balloon-expandable valves). AECG was started 1 (0-1) day after TAVI (monitoring time: 14121314 days). NOAF was detected in 49 patients (7%), with a median duration of 185 (43-421) minutes (atrial fibrillation burden of 0.7% [0.3-2.8]). Anticoagulation was started in 25 NOAF patients (51%). No differences were found in baseline or procedural characteristics, except for a higher AS severity in the NOAF group (peak gradient: no NOAF: 71.9±23.5 mmHg vs NOAF: 85.2±23.8 mmHg; p=0.024; mean gradient: no NOAF: 44.4±14.7 mmHg vs NOAF: 53.8±16.8 mmHg; p=0.004). In the multivariable analysis, the baseline mean transaortic gradient was associated with a higher risk of NOAF after TAVI (odds ratio 1.04, 95% confidence interval: 1.01-1.06 for each mmHg; p=0.006). There were no differences between groups in all-cause mortality (no NOAF: 4.7% vs NOAF: 0%; p=0.122), stroke (no NOAF: 1.4% vs NOAF: 2.0%; p=0.723), or bleeding (no NOAF: 1.9% vs NOAF: 4.1%; p=0.288) from the 30-day to 1-year follow-up. CONCLUSIONS: NOAF detected with AECG occurred in 7% of TAVI recipients and was associated with a higher AS severity. NOAF detection determined the start of anticoagulation therapy in about half of the patients, and it was not associated with an increased risk of clinical events at 1-year follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica , Fibrilación Atrial , Electrocardiografía Ambulatoria , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Femenino , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Estenosis de la Válvula Aórtica/cirugía , Anciano de 80 o más Años , Electrocardiografía Ambulatoria/métodos , Factores de Riesgo , Resultado del Tratamiento
2.
Open Heart ; 11(1)2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38719499

RESUMEN

OBJECTIVE: Implantable loop recorders (ILRs) are increasingly used for long-term rhythm monitoring after ischaemic and cryptogenic stroke, with the goal of detecting atrial fibrillation (AF) and subsequent initiation of oral anticoagulation to reduce risk of adverse clinical outcomes. There is a need to determine the effectiveness of different rhythm monitoring strategies in this context. METHODS: We conducted a retrospective cohort analysis of individuals with commercial and Medicare Advantage insurance in Optum Labs Data Warehouse who had incident ischaemic or cryptogenic stroke and no prior cardiovascular implantable electronic device from 1 January 2016 to 30 June 2021. Patients were stratified by rhythm monitoring strategy: ILR, long-term continuous external cardiac monitor (>48 hours to 30 days) or Holter monitor (≤48 hours). The primary outcome was risk-adjusted all-cause mortality at 12 months. Secondary outcomes included new diagnosis of AF and oral anticoagulation, bleeding, and costs. RESULTS: Among 48 901 patients with ischaemic or cryptogenic stroke, 9235 received an ILR, 29 103 long-term continuous external monitor and 10 563 Holter monitor only. Mean age was 69.9 (SD 11.9) years and 53.5% were female. During the 12-month follow-up period, patients who received ILRs compared with those who received long-term continuous external monitors had a higher odds of new diagnosis of AF and oral anticoagulant initiation (adjusted OR 2.27, 95% CI 2.09 to 2.48). Compared with patients who received long-term continuous external monitors, those who received ILRs had similar 12-month mortality (HR 1.00; 95% CI 0.89 to 1.12), with approximately $13 000 higher costs at baseline (including monitor cost) and $2500 higher costs during 12-month follow-up. CONCLUSIONS: In this large real-world study of patients with ischaemic or cryptogenic stroke, ILR placement resulted in more diagnosis of AF and initiation of oral anticoagulation, but no difference in mortality compared with long-term continuous external monitors.


Asunto(s)
Fibrilación Atrial , Electrocardiografía Ambulatoria , Accidente Cerebrovascular Isquémico , Humanos , Femenino , Masculino , Anciano , Estudios Retrospectivos , Electrocardiografía Ambulatoria/instrumentación , Electrocardiografía Ambulatoria/economía , Electrocardiografía Ambulatoria/métodos , Accidente Cerebrovascular Isquémico/economía , Accidente Cerebrovascular Isquémico/mortalidad , Accidente Cerebrovascular Isquémico/diagnóstico , Accidente Cerebrovascular Isquémico/prevención & control , Accidente Cerebrovascular Isquémico/etiología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/economía , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/complicaciones , Fibrilación Atrial/mortalidad , Estados Unidos/epidemiología , Anticoagulantes/economía , Anticoagulantes/administración & dosificación , Factores de Tiempo , Persona de Mediana Edad , Estudios de Seguimiento , Análisis Costo-Beneficio , Anciano de 80 o más Años , Costos de la Atención en Salud
3.
Open Heart ; 11(1)2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38719497

RESUMEN

BACKGROUND: The treatment of pulmonary hypertension (PH) has improved rapidly in recent decades. There is increasing evidence to support the role of early intervention and treatment in affecting clinical outcomes in PH. OBJECTIVES: To assess treatment effects before and after the escalation of specific PH treatments using continuous heart monitoring with a Reveal LINQ loop recorder. METHODS: Patients were compared before and after treatment escalation. Treatment escalation was defined as an additional pulmonary arterial hypertension (PAH) drug, pulmonary endarterectomy, percutaneous balloon angioplasty or bilateral lung transplantation. Specifically, changes in heart rate variability (HRV), heart rate (HR) and physical activity were assessed. RESULTS: In this prospective study, 41 patients (27 with PAH and 14 with chronic thromboembolic pulmonary hypertension (CTEPH)) were enrolled. Among them, 15 (36.6%) patients underwent PH treatment escalation. Prior to escalation, patients were monitored for a median of 100 (range: 68-100) days and after therapy escalation for a median duration of 165 (range: 89-308) days. In the escalation group, there was a significant increase in HRV, physical activity indexed by daytime HR and a significant decrease in nighttime HR assessed at baseline and after treatment escalation in both the PAH and CTEPH groups. This was paralleled by significant improvements in WHO functional class, 6-min walking distance and N-terminal pro-b-type natriuretic peptide. CONCLUSIONS: This is the first study to demonstrate an association between specific PH therapies and changes in HRV, HR nighttime and physical activity. This indicates the potential of continuous monitoring in the evaluation of treatment effects in PH.


Asunto(s)
Frecuencia Cardíaca , Hipertensión Pulmonar , Humanos , Femenino , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Frecuencia Cardíaca/fisiología , Hipertensión Pulmonar/fisiopatología , Hipertensión Pulmonar/diagnóstico , Hipertensión Pulmonar/terapia , Resultado del Tratamiento , Endarterectomía/métodos , Anciano , Antihipertensivos/uso terapéutico , Factores de Tiempo , Angioplastia de Balón/métodos , Adulto , Trasplante de Pulmón , Electrocardiografía Ambulatoria/métodos , Arteria Pulmonar/fisiopatología
4.
Int J Cardiol ; 406: 132070, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38643802

RESUMEN

BACKGROUND: Cardiac involvement represents a major cause of morbidity and mortality in patients with myotonic dystrophy type 1 (DM1) and prevention of sudden cardiac death (SCD) is a central part of patient care. We investigated the natural history of cardiac involvement in patients with DM1 to provide an evidence-based foundation for adjustment of follow-up protocols. METHODS: Patients with genetically confirmed DM1 were identified. Data on patient characteristics, performed investigations (12 lead ECG, Holter monitoring and echocardiography), and clinical outcomes were retrospectively collected from electronic health records. RESULTS: We included 195 patients (52% men) with a mean age at baseline evaluation of 41 years (range 14-79). The overall prevalence of cardiac involvement increased from 42% to 66% after a median follow-up of 10.5 years. There was a male predominance for cardiac involvement at end of follow-up (74 vs. 44%, p < 0.001). The most common types of cardiac involvement were conduction abnormalities (48%), arrhythmias (35%), and left ventricular systolic dysfunction (21%). Only 17% of patients reported cardiac symptoms. The standard 12­lead ECG was the most sensitive diagnostic modality and documented cardiac involvement in 24% at baseline and in 49% at latest follow-up. However, addition of Holter monitoring and echocardiography significantly increased the diagnostic yield with 18 and 13% points at baseline and latest follow-up, respectively. Despite surveillance 35 patients (18%) died during follow-up; seven due to SCD. CONCLUSIONS: In patients with DM1 cardiac involvement was highly prevalent and developed during follow-up. These findings justify lifelong follow-up with ECG, Holter, and echocardiography. CLINICAL PERSPECTIVE: What is new? What are the clinical implications?


Asunto(s)
Distrofia Miotónica , Humanos , Distrofia Miotónica/complicaciones , Distrofia Miotónica/diagnóstico , Distrofia Miotónica/fisiopatología , Distrofia Miotónica/epidemiología , Masculino , Femenino , Adulto , Persona de Mediana Edad , Estudios de Seguimiento , Adulto Joven , Estudios Retrospectivos , Adolescente , Anciano , Electrocardiografía Ambulatoria/métodos , Ecocardiografía/métodos , Cardiopatías/etiología , Cardiopatías/diagnóstico , Cardiopatías/epidemiología , Electrocardiografía
5.
BMC Neurol ; 24(1): 120, 2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38605308

RESUMEN

BACKGROUND: Atrial fibrillation (AF) screening after ischemic stroke or transient ischemic attack (TIA) is given high priority in clinical guidelines. However, patient selection, electrocardiogram (ECG) modality and screening duration remains undecided and current recommendations vary. METHODS: The aim of this study was to investigate the clinical practice of AF screening after ischemic stroke or TIA at Swedish stroke units. In collaboration with the stakeholders of the Swedish Stroke Register (Riksstroke) a digital survey was drafted, then tested and revised by three stroke consultants. The survey consisted of 17 multiple choice/ free text questions and was sent by e-mail to the medical directors at all stroke units in Sweden. RESULTS: All 72 stroke units in Sweden responded to the survey. Most stroke units reported that ≥ 75% of ischemic stroke (69/72 stroke units) or TIA patients (67/72 stroke units), without previously known AF, were screened for AF. Inpatient telemetry ECG was the method of first-choice in 81% of the units, but 7% reported lack of access. A variety of standard monitoring durations were used for inpatient telemetry ECG. The second most common choice was Holter ECG (17%), also with considerable variations in monitoring duration. Other AF screening modalities were used as a first-choice method (handheld and patch ECG) but less frequently. CONCLUSIONS: Clinical practice for AF screening after ischemic stroke or TIA differed between Swedish stroke units, both in choice of AF screening methods as well as in monitoring durations. There is an urgent need for evidence and evidence-based recommendations in this field. TRIAL REGISTRATION: Not applicable.


Asunto(s)
Fibrilación Atrial , Ataque Isquémico Transitorio , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Ataque Isquémico Transitorio/complicaciones , Ataque Isquémico Transitorio/diagnóstico , Ataque Isquémico Transitorio/epidemiología , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Suecia/epidemiología , Electrocardiografía Ambulatoria , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología
6.
Korean J Intern Med ; 39(3): 469-476, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38632895

RESUMEN

BACKGROUND/AIMS: The reimbursement policy for cryptogenic stroke (CS) was expanded in November 2018 from recurrent strokes to the first stroke episode. No reports have demonstrated whether this policy change has affected trends in implantable loop recorder (ILR) utilization. METHODS: We identified patients who received an ILR implant using the Korea Health Insurance Review and Assessment Service database between July 2016 and October 2021. Patients meeting all the following criteria were considered to have CS indication: 1) prior stroke history, 2) no previous history of atrial fibrillation or flutter (AF/AFL), and 3) no maintenance of oral anticoagulant for ≥4 weeks within a year before ILR implant. AF/AFL diagnosed within 3 years after ILR implant or before ILR removal was considered ILR-driven. RESULTS: Among 3,056 patients, 1,001 (32.8%) had CS indications. The total ILR implant number gradually increased for both CS and non-CS indications and the number of CS indication significantly increased after implementing the expanded reimbursement policy. The detection rate for AF/AFL was 26.3% in CS patients over 3 years, which was significantly higher in patients implanted with an ILR within 2 months after stroke than those implanted later. CONCLUSION: The expanded coverage policy for CS had a significant impact on the number of ILR implantation for CS indication. The diagnostic yield of ILR for AF/AFL detection seems better when ILR is implanted within 2 months than later. Further investigation is needed to demonstrate other clinical benefits and the optimal ILR implantation timing.


Asunto(s)
Accidente Cerebrovascular Isquémico , Humanos , República de Corea , Masculino , Femenino , Persona de Mediana Edad , Anciano , Accidente Cerebrovascular Isquémico/diagnóstico , Bases de Datos Factuales , Factores de Tiempo , Reembolso de Seguro de Salud , Estudios Retrospectivos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/economía , Electrocardiografía Ambulatoria/instrumentación , Electrocardiografía Ambulatoria/economía , Adulto
7.
Sci Rep ; 14(1): 8969, 2024 04 18.
Artículo en Inglés | MEDLINE | ID: mdl-38637619

RESUMEN

Duchenne muscular dystrophy (DMD) patients exhibit a late left ventricular systolic dysfunction preceded by an occult phase, during which myocardial fibrosis progresses and some early functional impairments can be detected. These latter include electrocardiographic (ECG) and heart rate variability (HRV) abnormalities. This longitudinal study aimed at describing the sequence of ECG and HRV abnormalities, using Holter ECG in the GRMD (Golden retriever muscular dystrophy) dog model, known to develop a DMD-like disease, including cardiomyopathy. Most of the known ECG abnormalities described in DMD patients were also found in GRMD dogs, including increased heart rate, prolonged QT and shortened PR intervals, ventricular arrhythmias, and several of them could be detected months before the decrease of fractional shortening. The HRV was impaired like in DMD patients, one of the earliest evidenced abnormalities being a decrease in the very low frequency (VLF) component of the power spectrum. This decrease was correlated with the further reduction of fractional shortening. Such decreased VLF probably reflects impaired autonomic function and abnormal vasomotor tone. This study provides new insights into the knowledge of the GRMD dog model and DMD cardiomyopathy and emphasizes the interest to monitor the VLF power in DMD patients, still unexplored in this disease, whilst it is highly predictive of deleterious clinical events in many other pathological conditions.


Asunto(s)
Cardiomiopatías , Distrofia Muscular de Duchenne , Humanos , Perros , Animales , Distrofia Muscular de Duchenne/patología , Frecuencia Cardíaca , Electrocardiografía Ambulatoria , Estudios Longitudinales
8.
Comput Methods Programs Biomed ; 249: 108157, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38582037

RESUMEN

BACKGROUND AND OBJECTIVE: T-wave alternans (TWA) is a fluctuation in the repolarization morphology of the ECG. It is associated with cardiac instability and sudden cardiac death risk. Diverse methods have been proposed for TWA analysis. However, TWA detection in ambulatory settings remains a challenge due to the absence of standardized evaluation metrics and detection thresholds. METHODS: In this work we use traditional TWA analysis signal processing-based methods for feature extraction, and two machine learning (ML) methods, namely, K-nearest-neighbor (KNN) and random forest (RF), for TWA detection, addressing hyper-parameter tuning and feature selection. The final goal is the detection in ambulatory recordings of short, non-sustained and sparse TWA events. RESULTS: We train ML methods to detect a wide variety of alternant voltage from 20 to 100 µV, i.e., ranging from non-visible micro-alternans to TWA of higher amplitudes, to recognize a wide range in concordance to risk stratification. In classification, RF outperforms significantly the recall in comparison with the signal processing methods, at the expense of a small lost in precision. Despite ambulatory detection stands for an imbalanced category context, the trained ML systems always outperform signal processing methods. CONCLUSIONS: We propose a comprehensive integration of multiple variables inspired by TWA signal processing methods to fed learning-based methods. ML models consistently outperform the best signal processing methods, yielding superior recall scores.


Asunto(s)
Arritmias Cardíacas , Electrocardiografía Ambulatoria , Humanos , Electrocardiografía Ambulatoria/métodos , Frecuencia Cardíaca , Arritmias Cardíacas/diagnóstico , Muerte Súbita Cardíaca , Procesamiento de Señales Asistido por Computador , Electrocardiografía/métodos
10.
Medicina (Kaunas) ; 60(4)2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38674301

RESUMEN

Coronavirus disease 2019 (COVID-19) has affected medical practice. More than 7,000,000 patients died worldwide after being infected with COVID-19; however, no specific laboratory markers have yet been established to predict death related to this disease. In contrast, electrocardiographic changes due to COVID-19 include QT prolongation and ST-T changes; however, there have not been studies on the ambulatory electrocardiographic markers of COVID-19. We encountered three patients diagnosed as having COVID-19 who did not have a prior history of significant structural heart diseases. All patients had abnormalities in ambulatory echocardiogram parameters detected by high-resolution 24 h electrocardiogram monitoring: positive late potentials (LPs) and T-wave alternans (TWA), abnormal heart rate variability (HRV), and heart rate turbulence (HRT). Case 1 involved a 78-year-old woman with a history of chronic kidney disease, Case 2 involved a 76-year-old man with hypertension and diabetes, and Case 3 involved a 67-year-old man with renal cancer, lung cancer, and diabetes. None of them had a prior history of significant structural heart disease. Although no significant consistent increases in clinical markers were observed, all three patients died, mainly because of respiratory failure with mild heart failure. The LP, TWA, HRV, and HRT were positive in all three cases with no significant structural cardiac disease at the initial phase of admission. The further accumulation of data regarding ambulatory electrocardiographic markers in patients with COVID-19 is needed. Depending on the accumulation of data, the LP, TWA, HRV, and HRT could be identified as potential risk factors for COVID-19 pneumonia in the early phase of admission.


Asunto(s)
COVID-19 , Electrocardiografía Ambulatoria , SARS-CoV-2 , Humanos , COVID-19/complicaciones , COVID-19/fisiopatología , COVID-19/diagnóstico , Anciano , Femenino , Masculino
11.
Clin Cardiol ; 47(4): e24266, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38587231

RESUMEN

BACKGROUND: Electrocardiography (ECG) and 24 hours Holter monitoring (24 h-Holter) provided valuable information for premature ventricular and supraventricular contractions (PVC and PSVC). Currently, artificial intelligence (AI) based 2 hours single-lead Holter (2 h-Holter) monitoring may provide an improved strategy for PSVC/PVC diagnosis. HYPOTHESIS: AI combined with single-lead Holter monitoring improves PSVC/PVC detection. METHODS: In total, 170 patients were enrolled between August 2022 and 2023. All patients wore both devices simultaneously; then, we compared diagnostic efficiency, including the sensitivity/specificity/positive predictive-value (PPV) and negative predictive-value (NPV) in detecting PSVC/PVC by 24 h-Holter and 2 h-Holter. RESULTS: The PPV and NPV in patients underwent 2 h-Holter were 76.00%/87.50% and 96.35%/98.55, respectively, and the sensitivity and specificity were 79.17%/91.30%, and 95.65%/97.84% in PSVC/PVC detection compared with 24 h-Holter. The areas under the ROC curves (AUCs) for PSVC and PVC were 0.885 and 0.741, respectively (p < .0001). CONCLUSIONS: The potential advantages of the 2 h-Holter were shortened wearing period, improved convenience, and excellent consistency of diagnosis.


Asunto(s)
Electrocardiografía Ambulatoria , Complejos Prematuros Ventriculares , Humanos , Inteligencia Artificial , Complejos Prematuros Ventriculares/diagnóstico , Electrocardiografía , Valor Predictivo de las Pruebas
12.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38584469

RESUMEN

AIMS: Brugada syndrome (BrS) diagnosis and risk stratification rely on the presence of a spontaneous type 1 (spT1) electrocardiogram (ECG) pattern; however, its spontaneous fluctuations may lead to misdiagnosis and risk underestimation. This study aims to assess the role for repeat high precordial lead (HPL) resting and ambulatory ECG monitoring in identifying a spT1, and evaluate its prognostic role. METHODS AND RESULTS: HPL resting and ambulatory monitoring ECGs of BrS subjects were reviewed retrospectively, and the presence of a spT1 associated with ventricular dysrhythmias and sudden cardiac death (SCD). Three-hundred and fifty-eight subjects (77 with spT1 pattern at presentation, Group 1, and 281 without, Group 2) were included. In total, 1651 resting HPL resting and 621 ambulatory monitoring ECGs were available for review, or adequately described. Over a median follow-up of 72 months (interquartile range - IQR - 75), 42/77 (55%) subjects in Group 1 showed a spT1 in at least one ECG. In Group 2, 36/281 subjects (13%) had a newly detected spT1 (1.9 per 100 person-year) and 23 on an HPL ambulatory recording (8%). Seven previously asymptomatic subjects, five of whom had a spT1 (four at presentation and one at follow-up), experienced arrhythmic events; survival analysis indicated that a spT1, either at presentation or during lifetime, was associated with events. Univariate models showed that a spT1 was consistently associated with increased risk [spT1 at presentation: hazard ratio (HR) 6.3, 95% confidence interval (CI) 1.4-28, P = 0.016; spT1 at follow-up: HR 3.1, 95% CI 1.3-7.2, P = 0.008]. CONCLUSION: Repeated ECG evaluation and HPL ambulatory monitoring are vital in identifying transient spT1 Brugada pattern and its associated risk.


Asunto(s)
Síndrome de Brugada , Muerte Súbita Cardíaca , Electrocardiografía Ambulatoria , Humanos , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/fisiopatología , Masculino , Femenino , Electrocardiografía Ambulatoria/métodos , Persona de Mediana Edad , Estudios Retrospectivos , Pronóstico , Adulto , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/prevención & control , Medición de Riesgo , Valor Predictivo de las Pruebas , Factores de Riesgo , Frecuencia Cardíaca , Anciano
13.
Brain Behav ; 14(5): e3489, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38688880

RESUMEN

OBJECTIVE: To investigate the circadian changes of the autonomic function in patients with zoster-associated pain (ZAP). METHODS: A total of 37 patients with ZAP from April 2022 to October 2022 were enrolled as the observation group, and 37 normal volunteers at the same time were selected as the control group. All participants were required to wear a 24-h Holter, which was used to compare the heart rate variability (HRV) between the two groups. HRV analysis involved time- and frequency-domain parameters. RESULTS: There was no statistically significant difference in general information between two groups. Patients with ZAP had an increased mean heart rate and decreased the standard deviation of normal-to-normal (SDNN) R-R interval, the root mean square of the differences (RMSSD) in successive RR interval, low frequency (LF), and high frequency (HF) compared with control groups in all periods (p < .05). The ratio of LF/HF between two groups had no significant difference (p = .245). SDNN had no significant difference between day and night in the control group (p > .05), whereas SDNN of ZAP patients in night period was reduced than that in day period (p < .001). The level of RMSSD during the day was lower than those at night in the control group (p < .05), whereas no significant difference of RMSSD between two periods was observed in patients with ZAP (p > .05). CONCLUSION: The results of this study indicated that ZAP contributes to the decline of autonomic nervous system (ANS) function, especially parasympathetic components. The patients with ZAP lost parasympathetic advantage and had a worse ANS during the night.


Asunto(s)
Sistema Nervioso Autónomo , Ritmo Circadiano , Frecuencia Cardíaca , Herpes Zóster , Humanos , Masculino , Frecuencia Cardíaca/fisiología , Femenino , Ritmo Circadiano/fisiología , Persona de Mediana Edad , Sistema Nervioso Autónomo/fisiopatología , Anciano , Herpes Zóster/fisiopatología , Herpes Zóster/complicaciones , Electrocardiografía Ambulatoria , Adulto
14.
Pacing Clin Electrophysiol ; 47(5): 702-705, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38491749

RESUMEN

BACKGROUND: Individuals with developmental and/or intellectual disabilities (I/DD) are at a greater risk for atrial fibrillation (AF), the most common type of cardiac arrhythmia. AF is associated with heart failure, stroke, poor mental health, and reduced quality of life. Management and treatment decisions are based on the ability to detect AF; however, noninvasive, remote cardiac monitoring may not be tolerated by individuals with I/DD. OBJECTIVE: To examine adherence to the placement of an ambulatory cardiac rhythm monitoring patch device by adult patients with I/DD. METHODS: Investigators extracted chart data from a consecutive series of adult patients (18 years+) who received the patch device as part of standard treatment at an adult health center between November 1, 2015 and October 31, 2019. RESULTS: A total of 95 patients were included in data analysis. Average age of subjects was 53.8 ± 13.9 years (range: 20.2-88.5); 66.7% were male. All subjects had intellectual disabilities as follows: mild, 37.9%; moderate, 29.5%; severe, 21.0%; and, profound, 11.6%. With a prescribed duration of 14 days, subjects wore the device a median (interquartile range [IQR]) of 12.2 days (4.1-14.0); total analysis time was a median of 9.5 days (3.4-13.5). A total of 29 subjects (30.5%) received cardiac diagnoses not previously identified (median = 1 new diagnosis; range: 1-5). CONCLUSIONS: This pilot study suggests the possible utility of an ambulatory monitoring patch device in an adult population with I/DD. Investigators recommend larger studies to confirm such preliminary findings to ultimately improve clinical management and patient quality of life.


Asunto(s)
Electrocardiografía Ambulatoria , Cooperación del Paciente , Humanos , Masculino , Femenino , Persona de Mediana Edad , Adulto , Anciano , Anciano de 80 o más Años , Fibrilación Atrial , Adhesivos , Personas con Discapacidad , Discapacidad Intelectual/complicaciones
15.
J Med Internet Res ; 26: e46098, 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38512332

RESUMEN

BACKGROUND: Wearable electrocardiogram (ECG) monitoring devices are used worldwide. However, data on the diagnostic yield of an adhesive single-lead ECG patch (SEP) to detect premature ventricular complex (PVC) and the optimal duration of wearing an SEP for PVC burden assessment are limited. OBJECTIVE: We aimed to validate the diagnostic yield of an SEP (mobiCARE MC-100, Seers Technology) for PVC detection and evaluate the PVC burden variation recorded by the SEP over a 3-day monitoring period. METHODS: This is a prospective study of patients with documented PVC on a 12-lead ECG. Patients underwent simultaneous ECG monitoring with the 24-hour Holter monitor and SEP on the first day. On the subsequent second and third days, ECG monitoring was continued using only SEP, and a 3-day extended monitoring was completed. The diagnostic yield of SEP for PVC detection was evaluated by comparison with the results obtained on the first day of Holter monitoring. The PVC burden monitored by SEP for 3 days was used to assess the daily and 6-hour PVC burden variations. The number of patients additionally identified to reach PVC thresholds of 10%, 15%, and 20% during the 3-day extended monitoring by SEP and the clinical factors associated with the higher PVC burden variations were explored. RESULTS: The recruited data of 134 monitored patients (mean age, 54.6 years; males, 45/134, 33.6%) were analyzed. The median daily PVC burden of these patients was 2.4% (IQR 0.2%-10.9%), as measured by the Holter monitor, and 3.3% (IQR 0.3%-11.7%), as measured in the 3-day monitoring by SEP. The daily PVC burden detected on the first day of SEP was in agreement with that of the Holter monitor: the mean difference was -0.07%, with 95% limits of agreement of -1.44% to 1.30%. A higher PVC burden on the first day was correlated with a higher daily (R2=0.34) and 6-hour burden variation (R2=0.48). Three-day monitoring by SEP identified 29% (12/42), 18% (10/56), and 7% (4/60) more patients reaching 10%, 15%, and 20% of daily PVC burden, respectively. Younger age was additionally associated with the identification of clinically significant PVC burden during the extended monitoring period (P=.02). CONCLUSIONS: We found that the mobiCARE MC-100 SEP accurately detects PVC with comparable diagnostic yield to the 24-hour Holter monitor. Performing 3-day PVC monitoring with SEP, especially among younger patients, may offer a pragmatic alternative for identifying more individuals exceeding the clinically significant PVC burden threshold.


Asunto(s)
Complejos Prematuros Ventriculares , Masculino , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Complejos Prematuros Ventriculares/diagnóstico , Electrocardiografía , Electrocardiografía Ambulatoria , Tecnología
16.
Stroke ; 55(4): 946-953, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38436115

RESUMEN

BACKGROUND: Covert atrial fibrillation (AF) is a major cause of cryptogenic stroke. This study investigated whether a dose-dependent relationship exists between the frequency of premature atrial contractions (PACs) and AF detection in patients with cryptogenic stroke using an insertable cardiac monitor (ICM). METHODS: We enrolled consecutive patients with cryptogenic stroke who underwent ICM implantation between October 2016 and September 2020 at 8 stroke centers in Japan. Patients were divided into 3 groups according to the PAC count on 24-hour Holter ECG: ≤200 (group L), >200 to ≤500 (group M), and >500 (group H). We defined a high AF burden as above the median of the cumulative duration of AF episodes during the entire monitoring period. We evaluated the association of the frequency of PACs with AF detection using log-rank trend test and Cox proportional hazard model and with high AF burden using logistic regression model, adjusting for age, sex, CHADS2 score. RESULTS: Of 417 patients, we analyzed 381 patients with Holter ECG and ICM data. The median age was 70 (interquartile range, 59.5-76.5), 246 patients (65%) were males, and the median duration of ICM recording was 605 days (interquartile range, 397-827 days). The rate of new AF detected by ICM was higher in groups with more frequent PAC (15.5%/y in group L [n=277] versus 44.0%/y in group M [n=42] versus 71.4%/y in group H [n=62]; log-rank trend P<0.01). Compared with group L, the adjusted hazard ratios for AF detection in groups M and H were 2.11 (95% CI, 1.24-3.58) and 3.23 (95% CI, 2.07-5.04), respectively, and the adjusted odds ratio for high AF burden in groups M and H were 2.57 (95% CI, 1.14-5.74) and 4.25 (2.14-8.47), respectively. CONCLUSIONS: The frequency of PACs was dose-dependently associated with AF detection in patients with cryptogenic stroke.


Asunto(s)
Fibrilación Atrial , Complejos Atriales Prematuros , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Masculino , Humanos , Anciano , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/complicaciones , Complejos Atriales Prematuros/diagnóstico , Complejos Atriales Prematuros/epidemiología , Complejos Atriales Prematuros/complicaciones , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular Isquémico/complicaciones , Electrocardiografía Ambulatoria
17.
Eur J Pediatr ; 183(5): 2375-2382, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38446228

RESUMEN

Although the mechanisms underlying the pathophysiology of long COVID condition are still debated, there is growing evidence that autonomic dysfunction may play a role in the long-term complications or persisting symptoms observed in a significant proportion of patients after SARS-CoV-2 infection. However, studies focused on autonomic dysfunction have primarily been conducted in adults, while autonomic function has not yet been investigated in pediatric subjects. In this study, for the first time, we assessed whether pediatric patients with long COVID present abnormalities in autonomic cardiac function. Fifty-six long COVID pediatric patients (mean age 10.3 ± 3.8 y) and 27 age-, sex-, and body surface area-matched healthy controls (mean age 10.4 ± 4.5y) underwent a standard 12-lead electrocardiography (ECG) and 24-h ECG Holter monitoring. Autonomic cardiac function was assessed by time-domain and frequency-domain heart rate variability parameters. A comprehensive echocardiographic study was also obtained by two-dimensional echocardiography and tissue Doppler imaging. Data analysis showed that pediatric patients with long COVID had significant changes in HRV variables compared to healthy controls: significantly lower r-MSSD (root mean square of successive RR interval differences, 47.4 ± 16.9 versus 60.4 ± 29.1, p = 0.02), significant higher values VLF (very low frequency, 2077.8 ± 1023.3 versus 494.3 ± 1015.5 ms, p = 0.000), LF (low frequency, 1340.3 ± 635.6 versus 354.6 ± 816.8 ms, p = 0.000), and HF (high frequency, 895.7 ± 575.8 versus 278.9 ± 616.7 ms, p = 0.000). No significant differences were observed between the two groups both in systolic and diastolic parameters by echocardiography.  Conclusion: These findings suggest that pediatric patients with long COVID have an imbalance of cardiac autonomic function toward a relative predominance of parasympathetic tone, as already reported in adult patients with long COVID. Further studies are needed to clarify the clinical significance of this autonomic dysfunction and demonstrate its role as a pathophysiological mechanism of long COVID, paving the way for effective therapeutic and preventive strategies. What is Known: • Long Covid in children has been described globally, but studies have mostly focused on collecting the temporal evolution of persisting symptoms. What is New: • Cardiac autonomic imbalance toward a relative predominance of parasympathetic tone is a mechanism underlying Long Covid in children, as also described in adults.


Asunto(s)
Sistema Nervioso Autónomo , COVID-19 , Electrocardiografía Ambulatoria , Frecuencia Cardíaca , Humanos , Masculino , Femenino , Niño , Estudios de Casos y Controles , COVID-19/fisiopatología , COVID-19/complicaciones , Adolescente , Frecuencia Cardíaca/fisiología , Sistema Nervioso Autónomo/fisiopatología , Síndrome Post Agudo de COVID-19 , Corazón/fisiopatología , Electrocardiografía , Ecocardiografía , SARS-CoV-2
18.
Ital J Pediatr ; 50(1): 54, 2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38500213

RESUMEN

BACKGROUND: There are different findings on heart rate variability (HRV) and pediatric obstructive sleep apnea (pOSA) by an overnight HRV or a 1-hr HRV. However, there is limited data of HRV and pOSA diagnosis by using a 24-h HRV test. This study aimed to evaluate if HRV had potential for OSA diagnosis by using a 24-h HRV test. METHODS: This was a prospective study included children age between 5 and 15 years old, presenting with snoring, underwent polysomnography and a 24-h Holter monitoring. Predictors for pOSA diagnosis were analyzed using logistic regression analysis. RESULTS: During the study period, there were 81 pediatric patients met the study criteria. Of those, 65 patients (80.25%) were diagnosed as OSA. There were three factors were independently associated with OSA: standard deviation of all normal interval (SDNN), high frequency (HF), and low frequency (LF). The adjusted odds ratios of these factors were 0.949 (95% confidence interval 0.913, 0.985), 0.786 (95% confidence interval 0.624, 0.989), and 1.356 (95% confidence interval 1.075, 1.709). CONCLUSIONS: HRV parameters including SDNN, HF, and LF were associated with pOSA diagnosis in children by using the 24-h Holter monitoring.


Asunto(s)
Apnea Obstructiva del Sueño , Humanos , Niño , Preescolar , Adolescente , Frecuencia Cardíaca/fisiología , Estudios Prospectivos , Apnea Obstructiva del Sueño/diagnóstico , Electrocardiografía Ambulatoria , Polisomnografía
19.
Kardiol Pol ; 82(3): 353-359, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38493471

RESUMEN

Implantable loop recorders (ILR) are considered increasingly helpful in diagnosing cardio-neurological conditions, especially if arrhythmic events are of high clinical importance but are unlikely to be captured by standard methods of electrocardiogram recording due to the low frequency of events and short duration of a single event. The compelling evidence from randomized trials and observational studies strongly supports ILR utilization in patients after cryptogenic stroke or transient ischemic attack and in patients with recurrent transient loss of consciousness of unknown origin. These two groups of patients are expected to gain the most from initiating ILR-driven clinically effective management strategies. Stroke or transient ischemic attack survivors with detected subclinical atrial fibrillation can be switched from antiplatelets to anticoagulants, whilst patients with recurrent syncope may avoid severe injuries and/or substantial impairment of their quality of life. This joint opinion of the Heart Rhythm Association of the Polish Cardiac Society and experts from the Polish Neurological Society summarizes the up-to-date rationale for using ILR in everyday clinical practice and describes the road map for implementing this technology in Poland. Special emphasis is placed on the most recent guidelines issued by both cardiological and neurological scientific societies.


Asunto(s)
Fibrilación Atrial , Ataque Isquémico Transitorio , Humanos , Polonia , Testimonio de Experto , Calidad de Vida , Fibrilación Atrial/diagnóstico , Electrocardiografía Ambulatoria
20.
Europace ; 26(3)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38466042

RESUMEN

AIMS: Premature ventricular contractions (PVC) and non-sustained ventricular tachycardia (NSVT) are commonly observed in light chain cardiac amyloidosis (AL-CA), but their association with prognosis is still unclear. We aimed to evaluate the prognostic value of PVCs and NSVT in patients with moderate-to-advanced AL-CA. METHODS AND RESULTS: We retrospectively included patients with AL-CA at modified 2004 Mayo stages II-IIIb between February 2014 and December 2020. Twenty-four-hour Holter recordings were assessed on admission. The outcomes included (i) new onset of adverse ventricular arrhythmia (VA) or sudden cardiac death (SCD) and (ii) cardiac death during follow-up. Of the 143 patients studied (60.41 ± 11.06 years, male 64.34%), 132 (92.31%) had presence of PVC, and 50 (34.97%) had NSVT on Holter. Twelve (8.4%) patients died in hospital and 131 patients were followed up (median 24.4 months), among whom 71 patients had cardiac death, and 15 underwent adverse VA/SCD. NSVT [hazard ratio (HR): 13.57, 95% confidence interval (CI): 3.06-60.18, P < 0.001], log-transformed PVC counts (HR: 1.46, 95%CI: 1.15-1.86, P = 0.002) and PVC burden (HR: 1.43 95%CI:1.14-1.80, P = 0.002) were predictive of new onset of adverse VA/SCD. The highest tertile of PVC counts (HR: 2.33, 95%CI: 1.27-4.28, P = 0.006) and PVC burden (HR: 2.58, 95%CI: 1.42-4.69, P = 0.002), rather than NSVT (HR: 1.16, 95%CI: 0.67-1.98, P = 0.603), was associated with cardiac death. Higher PVC counts/burden provided incremental value on modified 2004 Mayo stage in predicting cardiac death, with C index increasing from 0.681 to 0.712 and 0.717, respectively (P values <0.05). CONCLUSION: PVC count, burden, and NSVT significantly correlated with adverse VA/SCD during follow-up in patients with AL-CA. Higher PVC counts/burdens added incremental value for predicting cardiac death.


Asunto(s)
Taquicardia Ventricular , Complejos Prematuros Ventriculares , Humanos , Masculino , Pronóstico , Estudios Retrospectivos , Electrocardiografía Ambulatoria , Muerte Súbita Cardíaca
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...