Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
Malar J ; 20(1): 365, 2021 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-34496850

RESUMEN

BACKGROUND: A malaria slide bank (MSB) is a useful asset for any malaria microscopy testing laboratory to have access to. However, it is not feasible for every country to have its own MSB. If countries are able to pool their resources, a regional MSB is a viable solution. This paper describes the methodology, costing and lessons learnt of establishing and maintaining an MSB over a 3-year period, for a Southern Africa Development Community region. METHODS: A national reference laboratory in South Africa was granted funding for setting up the MSB; it possessed experienced staff and suitable resources. Two additional full-time personnel were employed to carry out the activities of this project. Strict protocols for donor/patient blood sample screening, smear preparation, mass staining, quality control and slide validation were followed. Slides from the MSB were used for training and proficiency testing purposes. The initial and recurrent yearly costs to set up and maintain the MSB were calculated. RESULTS: Over 35 months, 154 batches (26,623 slides) were prepared; the majority were Plasmodium falciparum. Ninety-two percent (141/154) of batches passed internal quality control, and 89% (93/104) passed external validation. From these slides, two training slide sets and six proficiency testing slide sets were sent out. The initial year's cost to establish an MSB was calculated at approximately $165,000, and the recurrent year-on-year cost was $130,000. CONCLUSIONS: The key components for maintaining a high-quality MSB are consistent funding, competent staff and adherence to standardized protocols. Travel to malaria-endemic areas for access to non-falciparum malaria species, and dilution of P. falciparum blood to desired parasite densities, are extremely useful to ensure variety. The MSB created here supported multiple laboratories in eight countries, and has the potential to expand.


Asunto(s)
Cooperación Internacional , Laboratorios , Ensayos de Aptitud de Laboratorios/estadística & datos numéricos , Malaria/diagnóstico , Laboratorios/normas , Laboratorios/estadística & datos numéricos , Laboratorios/provisión & distribución , Plasmodium falciparum/aislamiento & purificación , Control de Calidad , Sudáfrica
2.
Arch Pathol Lab Med ; 145(2): 176-190, 2021 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-32886736

RESUMEN

CONTEXT.­: One goal of the joint College of American Pathologists/American College of Medical Genetics and Genomics Cytogenetics Committee is to ensure the accurate detection and description of chromosomal abnormalities in both constitutional and neoplastic specimens, including hematologic neoplasms. OBJECTIVE.­: To report a 20-year performance summary (1999-2018) of conventional chromosome challenges focusing on hematologic neoplasms. DESIGN.­: A retrospective review was performed from 1999 through 2018 to identify karyotype challenges specifically addressing hematologic neoplasms. The overall performance of participants was examined to identify potential recurring errors of clinical significance. RESULTS.­: Of 288 total conventional chromosome challenges from 1999-2018, 87 (30.2%) were presented in the context of a hematologic neoplasm, based on the provided clinical history, specimen type, and/or chromosomal abnormalities. For these 87 hematologic neoplasm challenges, 91 individual cases were provided and graded on the basis of abnormality recognition and karyotype nomenclature (ISCN, International System for Human Cytogenomic [previously Cytogenetic] Nomenclature). Of the 91 cases, 89 (97.8%) and 87 (95.6%) exceeded the required 80% consensus for grading of abnormality recognition and correct karyotype nomenclature, respectively. The 2 cases (2 of 91; 2.2%) that failed to meet the 80% consensus for abnormality recognition had complex karyotypes. The 4 cases (4 of 91; 4.4%) that failed to meet the 80% consensus for correct karyotype nomenclature were the result of incorrect abnormality recognition (2 cases), missing brackets in the karyotype (1 case), and incorrect breakpoint designation (1 case). CONCLUSIONS.­: This 20-year review demonstrates clinical cytogenetics laboratories have been and continue to be highly proficient in the detection and description of chromosomal abnormalities associated with hematologic neoplasms.


Asunto(s)
Aberraciones Cromosómicas , Neoplasias Hematológicas/diagnóstico , Ensayos de Aptitud de Laboratorios/estadística & datos numéricos , American Medical Association , Análisis Citogenético , Genética Médica , Genómica , Neoplasias Hematológicas/genética , Humanos , Cariotipo , Patólogos , Comité de Profesionales , Estados Unidos
3.
Am J Hum Genet ; 107(5): 932-941, 2020 11 05.
Artículo en Inglés | MEDLINE | ID: mdl-33108757

RESUMEN

Harmonization of variant pathogenicity classification across laboratories is important for advancing clinical genomics. The two CLIA-accredited Electronic Medical Record and Genomics Network sequencing centers and the six CLIA-accredited laboratories and one research laboratory performing genome or exome sequencing in the Clinical Sequencing Evidence-Generating Research Consortium collaborated to explore current sources of discordance in classification. Eight laboratories each submitted 20 classified variants in the ACMG secondary finding v.2.0 genes. After removing duplicates, each of the 158 variants was annotated and independently classified by two additional laboratories using the ACMG-AMP guidelines. Overall concordance across three laboratories was assessed and discordant variants were reviewed via teleconference and email. The submitted variant set included 28 P/LP variants, 96 VUS, and 34 LB/B variants, mostly in cancer (40%) and cardiac (27%) risk genes. Eighty-six (54%) variants reached complete five-category (i.e., P, LP, VUS, LB, B) concordance, and 17 (11%) had a discordance that could affect clinical recommendations (P/LP versus VUS/LB/B). 21% and 63% of variants submitted as P and LP, respectively, were discordant with VUS. Of the 54 originally discordant variants that underwent further review, 32 reached agreement, for a post-review concordance rate of 84% (118/140 variants). This project provides an updated estimate of variant concordance, identifies considerations for LP classified variants, and highlights ongoing sources of discordance. Continued and increased sharing of variant classifications and evidence across laboratories, and the ongoing work of ClinGen to provide general as well as gene- and disease-specific guidance, will lead to continued increases in concordance.


Asunto(s)
Enfermedades Cardiovasculares/genética , Variación Genética , Genómica/normas , Laboratorios/normas , Neoplasias/genética , Enfermedades Cardiovasculares/diagnóstico , Biología Computacional/métodos , Pruebas Genéticas , Genética Médica/métodos , Genoma Humano , Secuenciación de Nucleótidos de Alto Rendimiento , Humanos , Ensayos de Aptitud de Laboratorios/estadística & datos numéricos , Neoplasias/diagnóstico , Análisis de Secuencia de ADN , Programas Informáticos , Terminología como Asunto
4.
Ann Biol Clin (Paris) ; 78(5): 574-580, 2020 10 01.
Artículo en Francés | MEDLINE | ID: mdl-32716002

RESUMEN

Laboratories need to set up effective overall management of their internal quality control (IQC) and external quality assessment (EQA) results as key elements in statistical process control. Quality targets need to be defined, with methods to ensure durable control with respect to the relevant specifications. The hemostasis laboratory of the Lyon Hospitals Board (HCL, Lyon, France) uses model 3 from the Milan consensus conference, which is the state of the art in terms of quality targets, and uses a common EQA provider supplying as many real patient samples as possible. Giving priority to adopted methods, the lab optimizes the use of manufacturers' prior data: maximum acceptable inter assay coefficient of variation (CV) and prior IQC target values. Bayesian inference brings the method under control with respect to the manufacturers' prior data without the need for a preliminary phase. It links the IQC and EQA plans by the maximum acceptable CVs defined by the manufacturer.


Asunto(s)
Pruebas Hematológicas/estadística & datos numéricos , Pruebas Hematológicas/normas , Laboratorios de Hospital/estadística & datos numéricos , Garantía de la Calidad de Atención de Salud , Teorema de Bayes , Pruebas de Coagulación Sanguínea/instrumentación , Pruebas de Coagulación Sanguínea/métodos , Pruebas de Coagulación Sanguínea/normas , Pruebas de Coagulación Sanguínea/estadística & datos numéricos , Servicios de Laboratorio Clínico/organización & administración , Servicios de Laboratorio Clínico/normas , Servicios de Laboratorio Clínico/estadística & datos numéricos , Francia/epidemiología , Pruebas Hematológicas/instrumentación , Pruebas Hematológicas/métodos , Hemostasis/fisiología , Humanos , Laboratorios de Hospital/organización & administración , Laboratorios de Hospital/normas , Ensayos de Aptitud de Laboratorios/organización & administración , Ensayos de Aptitud de Laboratorios/normas , Ensayos de Aptitud de Laboratorios/estadística & datos numéricos , Práctica Profesional/organización & administración , Práctica Profesional/normas , Práctica Profesional/estadística & datos numéricos , Garantía de la Calidad de Atención de Salud/métodos , Garantía de la Calidad de Atención de Salud/organización & administración , Garantía de la Calidad de Atención de Salud/normas , Garantía de la Calidad de Atención de Salud/estadística & datos numéricos , Control de Calidad , Estudios Retrospectivos
5.
J Mycol Med ; 30(2): 100970, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32334948

RESUMEN

A survey of mycology laboratories for antifungal susceptibility testing (AFST) was undertaken in France in 2018, to better understand the difference in practices between the participating centers and to identify the difficulties they may encounter as well as eventual gaps with published standards and guidelines. The survey captured information from 45 mycology laboratories in France on how they perform AFST (number of strains tested, preferred method, technical and quality aspects, interpretation of the MIC values, reading and interpretation difficulties). Results indicated that 86% of respondents used Etest as AFST method, with a combination of one to seven antifungal agents tested. Most of the participating laboratories used similar technical parameters to perform their AFST method and a large majority used, as recommended, internal and external quality assessments. Almost all the participating mycology laboratories (98%) reported difficulties to interpret the MIC values, especially when no clinical breakpoints are available. The survey highlighted that the current AFST practices in France need homogenization, particularly for MIC reading and interpretation.


Asunto(s)
Antifúngicos/uso terapéutico , Laboratorios , Pruebas de Sensibilidad Microbiana , Micología , Práctica Profesional/estadística & datos numéricos , Pruebas Antimicrobianas de Difusión por Disco/métodos , Pruebas Antimicrobianas de Difusión por Disco/normas , Pruebas Antimicrobianas de Difusión por Disco/estadística & datos numéricos , Farmacorresistencia Fúngica , Francia , Historia del Siglo XXI , Humanos , Laboratorios/normas , Laboratorios/estadística & datos numéricos , Ensayos de Aptitud de Laboratorios/métodos , Ensayos de Aptitud de Laboratorios/estadística & datos numéricos , Pruebas de Sensibilidad Microbiana/métodos , Pruebas de Sensibilidad Microbiana/normas , Pruebas de Sensibilidad Microbiana/estadística & datos numéricos , Micología/historia , Micología/métodos , Micología/normas , Micología/estadística & datos numéricos , Práctica Profesional/normas , Control de Calidad , Encuestas y Cuestionarios
6.
Artículo en Inglés | MEDLINE | ID: mdl-32087845

RESUMEN

A database of micronuclei counts for historical negative control data from rat in vivo micronuclei tests performed in 10 different laboratories was established. Data were available from over 4000 negative control rats from 10 laboratories. The mean frequency of micronucleated cells (MN)/1000 cells ranged from 0.44 to 2.22, a 5-fold range. Overall there were no major sex or strain differences in frequency, although there were some small but statistically significant differences within laboratories. There was appreciable variability between experiments compared with variability within experiments in some laboratories. No specific factor was identified which could explain this variability although it was noted that many different vehicles were used in the experiments. It is hoped that these data will help laboratories beginning studies with the rat micronucleus assay and those involved in the assessment of micronucleus assay results.


Asunto(s)
Ensayos de Aptitud de Laboratorios/estadística & datos numéricos , Micronúcleos con Defecto Cromosómico/estadística & datos numéricos , Pruebas de Micronúcleos/normas , Animales , Femenino , Masculino , Pruebas de Micronúcleos/estadística & datos numéricos , Variaciones Dependientes del Observador , Control de Calidad , Ratas , Ratas Sprague-Dawley , Ratas Wistar , Reproducibilidad de los Resultados
7.
J Clin Microbiol ; 57(8)2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31167846

RESUMEN

Quality management and independent assessment of high-throughput sequencing-based virus diagnostics have not yet been established as a mandatory approach for ensuring comparable results. The sensitivity and specificity of viral high-throughput sequence data analysis are highly affected by bioinformatics processing using publicly available and custom tools and databases and thus differ widely between individuals and institutions. Here we present the results of the COMPARE [Collaborative Management Platform for Detection and Analyses of (Re-)emerging and Foodborne Outbreaks in Europe] in silico virus proficiency test. An artificial, simulated in silico data set of Illumina HiSeq sequences was provided to 13 different European institutes for bioinformatics analysis to identify viral pathogens in high-throughput sequence data. Comparison of the participants' analyses shows that the use of different tools, programs, and databases for bioinformatics analyses can impact the correct identification of viral sequences from a simple data set. The identification of slightly mutated and highly divergent virus genomes has been shown to be most challenging. Furthermore, the interpretation of the results, together with a fictitious case report, by the participants showed that in addition to the bioinformatics analysis, the virological evaluation of the results can be important in clinical settings. External quality assessment and proficiency testing should become an important part of validating high-throughput sequencing-based virus diagnostics and could improve the harmonization, comparability, and reproducibility of results. There is a need for the establishment of international proficiency testing, like that established for conventional laboratory tests such as PCR, for bioinformatics pipelines and the interpretation of such results.


Asunto(s)
Biología Computacional/métodos , Simulación por Computador , Secuenciación de Nucleótidos de Alto Rendimiento/normas , Ensayos de Aptitud de Laboratorios/estadística & datos numéricos , Análisis de Secuencia de ADN/normas , Virus/genética , Análisis de Datos , Europa (Continente) , Genoma Viral , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Humanos , Colaboración Intersectorial , Ensayos de Aptitud de Laboratorios/organización & administración , Reproducibilidad de los Resultados , Análisis de Secuencia de ADN/estadística & datos numéricos , Virus/patogenicidad
8.
Arch Pathol Lab Med ; 143(10): 1203-1211, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-30969158

RESUMEN

CONTEXT.­: The performance of laboratory testing has recently come under increased scrutiny as part of important and ongoing debates on regulation and reimbursement. To address this critical issue, this study compares the performance of assay methods, using either commercial kits or assays designed and implemented by single laboratories ("home brews"), including next-generation sequencing methods, on proficiency testing provided by the College of American Pathologists Molecular Oncology Committee. OBJECTIVE.­: To compare the performance of different assay methods on College of American Pathologists proficiency testing for variant analysis of 3 common oncology analytes: BRAF, EGFR, and KRAS. DESIGN.­: There were 6897 total responses across 35 different proficiency testing samples interrogating 13 different variants as well as wild-type sequences for BRAF, EGFR, and KRAS. Performance was analyzed by test method, kit manufacturer, variants tested, and preanalytic and postanalytic practices. RESULTS.­: Of 26 reported commercial kits, 23 achieved greater than 95% accuracy. Laboratory-developed tests with no kit specified demonstrated 96.8% or greater accuracy across all 3 analytes (1123 [96.8%] acceptable of 1160 total responses for BRAF; 848 [97.5%] acceptable of 870 total responses for EGFR; 942 [97.0%] acceptable of 971 total responses for KRAS). Next-generation sequencing platforms (summed across all analytes and 2 platforms) demonstrated 99.4% accuracy for these analytes (165 [99.4%] acceptable of 166 total next-generation sequencing responses). Slight differences in performance were noted among select commercial assays, dependent upon the particular design and specificity of the assay. Wide differences were noted in the lower limits of neoplastic cellularity laboratories accepted for testing. CONCLUSIONS.­: These data demonstrate the high degree of accuracy and comparable performance across all laboratories, regardless of methodology. However, care must be taken in understanding the diagnostic specificity and reported analytic sensitivity of individual methods.


Asunto(s)
Laboratorios/normas , Ensayos de Aptitud de Laboratorios/estadística & datos numéricos , Juego de Reactivos para Diagnóstico/normas , Exactitud de los Datos , Receptores ErbB/genética , Secuenciación de Nucleótidos de Alto Rendimiento/normas , Humanos , Oncología Médica , Mutación , Patólogos , Patología Molecular , Proteínas Proto-Oncogénicas B-raf/genética , Proteínas Proto-Oncogénicas p21(ras)/genética , Sensibilidad y Especificidad
9.
Am J Trop Med Hyg ; 99(4): 1096-1104, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30141389

RESUMEN

Hypoxemia measured by pulse oximetry predicts child pneumonia mortality in low-resource settings (LRS). Existing pediatric oximeter probes are prohibitively expensive and/or difficult to use, limiting LRS implementation. Using a human-centered design, we developed a low-cost, reusable pediatric oximeter probe for LRS health-care workers (HCWs). Here, we report probe usability testing. Fifty-one HCWs from Malawi, Bangladesh, and the United Kingdom participated, and seven experts provided reference measurements. Health-care workers and experts measured the peripheral arterial oxyhemoglobin saturation (SpO2) independently in < 5 year olds. Health-care worker measurements were classed as successful if recorded in 5 minutes (or shorter) and physiologically appropriate for the child, using expert measurements as the reference. All expert measurements were considered successful if obtained in < 5 minutes. We analyzed the proportion of successful SpO2 measurements obtained in < 1, < 2, and < 5 minutes and used multivariable logistic regression to predict < 1 minute successful measurements. We conducted four testing rounds with probe modifications between rounds, and obtained 1,307 SpO2 readings. Overall, 67% (876) of measurements were successful and achieved in < 1 minute, 81% (1,059) < 2 minutes, and 90% (1,181) < 5 minutes. Compared with neonates, increasing age (infant adjusted odds ratio [aOR]; 1.87, 95% confidence interval [CI]: 1.16, 3.02; toddler aOR: 4.33, 95% CI: 2.36, 7.97; child aOR; 3.90, 95% CI: 1.73, 8.81) and being asleep versus being calm (aOR; 3.53, 95% CI: 1.89, 6.58), were associated with < 1 minute successful measurements. In conclusion, we designed a novel, reusable pediatric oximetry probe that was effectively used by LRS HCWs on children. This probe may be suitable for LRS implementation.


Asunto(s)
Hipoxia/diagnóstico , Ensayos de Aptitud de Laboratorios/estadística & datos numéricos , Oximetría/instrumentación , Oxígeno/sangre , Oxihemoglobinas/análisis , Neumonía/diagnóstico , Adulto , Bangladesh , Niño , Equipo Reutilizado , Personal de Salud , Humanos , Hipoxia/sangre , Hipoxia/economía , Lactante , Recién Nacido , Modelos Logísticos , Malaui , Oximetría/economía , Neumonía/sangre , Neumonía/economía , Reino Unido
10.
PLoS One ; 13(7): e0198784, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30028852

RESUMEN

BACKGROUND: In sub-Saharan Africa, HIV, syphilis, malaria and anaemia are leading preventable causes of adverse pregnancy outcomes. In Kenya, policy states women should be tested for all four conditions (malaria only if febrile) at first antenatal care (ANC) visit. In practice, while HIV screening is conducted, coverage of screening for the others is suboptimal and early pregnancy management of illnesses is compromised. This is particularly evident at rural dispensaries that lack laboratories and have parallel programmes for HIV, reproductive health and malaria, resulting in fractured and inadequate care for women. METHODS: A longitudinal eight-month implementation study integrating point-of-care diagnostic tests for the four conditions into routine ANC was conducted in seven purposively selected dispensaries in western Kenya. Testing proficiency of healthcare workers was observed at initial training and at three monthly intervals thereafter. Adoption of testing was compared using ANC register data 8.5 months before and eight months during the intervention. Fidelity to clinical management guidelines was determined by client exit interviews with success defined as ≥90% adherence. FINDINGS: For first ANC visits at baseline (n = 529), testing rates were unavailable for malaria, low for syphilis (4.3%) and anaemia (27.8%), and near universal for HIV (99%). During intervention, over 95% of first attendees (n = 586) completed four tests and of those tested positive, 70.6% received penicillin or erythromycin for syphilis, 65.5% and 48.3% received cotrimoxazole and antiretrovirals respectively for HIV, and 76.4% received artemether/lumefantrine, quinine or dihydroartemisinin-piperaquine correctly for malaria. Iron and folic supplements were given to nearly 90% of women but often at incorrect doses. CONCLUSIONS: Integrating point-of-care testing into ANC at dispensaries with established HIV testing programmes resulted in a significant increase in testing rates, without disturbing HIV testing rates. While more cases were detected and treated, treatment fidelity still requires strengthening and an integrated monitoring and evaluation system needs to be established.


Asunto(s)
Anemia/diagnóstico , Suplementos Dietéticos , Infecciones por VIH/diagnóstico , Malaria/diagnóstico , Complicaciones Hematológicas del Embarazo/prevención & control , Complicaciones Infecciosas del Embarazo/prevención & control , Sífilis/diagnóstico , Adulto , Anemia/tratamiento farmacológico , Anemia/metabolismo , Antibacterianos/uso terapéutico , Fármacos Anti-VIH/uso terapéutico , Antimaláricos/uso terapéutico , Combinación Arteméter y Lumefantrina/uso terapéutico , Artemisininas/uso terapéutico , Eritromicina/uso terapéutico , Femenino , Ácido Fólico/administración & dosificación , Adhesión a Directriz , Infecciones por VIH/tratamiento farmacológico , Infecciones por VIH/metabolismo , Personal de Salud , Humanos , Hierro de la Dieta/administración & dosificación , Kenia , Ensayos de Aptitud de Laboratorios/estadística & datos numéricos , Estudios Longitudinales , Malaria/tratamiento farmacológico , Malaria/metabolismo , Penicilinas/uso terapéutico , Pruebas en el Punto de Atención/estadística & datos numéricos , Embarazo , Complicaciones Hematológicas del Embarazo/diagnóstico , Complicaciones Hematológicas del Embarazo/metabolismo , Complicaciones Infecciosas del Embarazo/diagnóstico , Complicaciones Infecciosas del Embarazo/metabolismo , Atención Prenatal/estadística & datos numéricos , Quinina/uso terapéutico , Quinolinas/uso terapéutico , Sífilis/tratamiento farmacológico , Sífilis/metabolismo , Combinación Trimetoprim y Sulfametoxazol/uso terapéutico
12.
Biochem Med (Zagreb) ; 28(2): 020702, 2018 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-29666555

RESUMEN

INTRODUCTION: This survey was initiated to obtain knowledge on the current situation of internal quality control (IQC) practice for tumour markers (TMs) in China. Additionally, we tried to acquire the most appropriate quality specifications. MATERIALS AND METHODS: This survey was a current status survey. The IQC information had been collected via online questionnaires. All of 1821 clinical laboratories which participated in the 2016 TMs external quality assessment (EQA) programme had been enrolled. The imprecision evaluation criteria were the minimal, desirable, and optimal allowable imprecisions based on biological variations, and 1/3 total allowable error (TEa) and 1/4 TEa. RESULTS: A total of 1628 laboratories answered the questionnaires (89%). The coefficients of variation (CVs) of the IQC of participant laboratories varied greatly from 1% (5th percentile) to 13% (95th percentile). More than 82% (82 - 91%) of participant laboratories two types of CVs met 1/3 TEa except for CA 19-9. The percentiles of current CVs were smaller than cumulative CVs. A number of 1240 laboratories (76%) reported their principles and systems used. The electrochemiluminescence was the most used principle (45%) and had the smallest CVs. CONCLUSIONS: The performance of laboratories for TMs IQC has yet to be improved. On the basis of the obtained results, 1/3 TEa would be realistic and attainable quality specification for TMs IQC for clinical laboratories in China.


Asunto(s)
Biomarcadores de Tumor/sangre , Técnicas para Inmunoenzimas/normas , Laboratorios de Hospital/normas , Ensayos de Aptitud de Laboratorios/estadística & datos numéricos , Neoplasias/sangre , Neoplasias/diagnóstico , Automatización de Laboratorios , China , Humanos , Mediciones Luminiscentes/normas , Neoplasias/patología , Control de Calidad , Encuestas y Cuestionarios
13.
J Clin Lab Anal ; 32(2)2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28493522

RESUMEN

BACKGROUND: This survey was initiated to estimate the current status of turnaround time (TAT) monitoring of clinical biochemistry in China, provide baseline data for establishment of quality specifications and analyze the impact factors of TAT. METHODS: 738 laboratories were included. Questionnaires involved general information and data of related indicators of TAT during 1 week were provided to participating laboratories. Nine quality indicators were covered, which were medians, 90th and outlier rates of pre-examination, examination, and post-examination TAT. The 25th percentile, median, and 75th percentile of TATs were calculated as optimum, desirable, and minimum quality specifications. Percentages and sigma values were used to describe the outlier rates. Mann-Whitney and Kruskal-Wallis tests were used to identify the potential impacts of TAT. RESULTS: Response rate of this survey was 46.44%. More than 50% of the laboratories indicated they had set up target TATs in three time intervals and monitored TATs generally. The post-examination TAT of most laboratories was 0min, while the pre-examination and examination TAT varied. Sigma values of outlier rates for 45%~60% of laboratories were above 4, while 15%~20% of labs whose sigma values were below 3. Group comparisons suggested nurse or mechanical pipeline transportation, link laboratory information system with hospital information system, and using computer reporting instead of printing report were related to shorter TATs. CONCLUSIONS: Despite of the remarkable progresses of TATs in China, there was also room to improve. Laboratories should strengthen the construction of information systems, identify reasons for TAT delay to improve the service quality continuously.


Asunto(s)
Pruebas de Química Clínica/estadística & datos numéricos , Pruebas de Química Clínica/normas , Laboratorios/estadística & datos numéricos , Ensayos de Aptitud de Laboratorios/estadística & datos numéricos , China , Humanos , Encuestas y Cuestionarios , Factores de Tiempo
15.
J Lipid Res ; 58(12): 2275-2288, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28986437

RESUMEN

As the lipidomics field continues to advance, self-evaluation within the community is critical. Here, we performed an interlaboratory comparison exercise for lipidomics using Standard Reference Material (SRM) 1950-Metabolites in Frozen Human Plasma, a commercially available reference material. The interlaboratory study comprised 31 diverse laboratories, with each laboratory using a different lipidomics workflow. A total of 1,527 unique lipids were measured across all laboratories and consensus location estimates and associated uncertainties were determined for 339 of these lipids measured at the sum composition level by five or more participating laboratories. These evaluated lipids detected in SRM 1950 serve as community-wide benchmarks for intra- and interlaboratory quality control and method validation. These analyses were performed using nonstandardized laboratory-independent workflows. The consensus locations were also compared with a previous examination of SRM 1950 by the LIPID MAPS consortium. While the central theme of the interlaboratory study was to provide values to help harmonize lipids, lipid mediators, and precursor measurements across the community, it was also initiated to stimulate a discussion regarding areas in need of improvement.


Asunto(s)
Benchmarking , Ensayos de Aptitud de Laboratorios/estadística & datos numéricos , Lípidos/sangre , Humanos , Cooperación Internacional , Metabolismo de los Lípidos/fisiología , Lípidos/normas , Variaciones Dependientes del Observador , Estándares de Referencia , Reproducibilidad de los Resultados
16.
Appl Radiat Isot ; 126: 249-251, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28431893

RESUMEN

In Japan, we conducted proficiency testing of activity measurement by using high-purity germanium detectors for 134Cs and 137Cs in brown rice grains. Among 176 reported results, 86 % (for 134Cs) and 93 % (for 137Cs) of the results satisfied |En| â‰¦ 1. However, 58 reports for 134Cs and 51 reports for 137Cs had some failures in their evaluations of uncertainties. The proficiency testing was effective to improve the ability of uncertainty evaluation.


Asunto(s)
Radioisótopos de Cesio/análisis , Contaminación Radiactiva de Alimentos/análisis , Oryza/química , Radiometría/métodos , Radioisótopos de Cesio/normas , Accidente Nuclear de Fukushima , Germanio , Humanos , Japón , Ensayos de Aptitud de Laboratorios/métodos , Ensayos de Aptitud de Laboratorios/normas , Ensayos de Aptitud de Laboratorios/estadística & datos numéricos , Radiometría/normas , Radiometría/estadística & datos numéricos , Estándares de Referencia , Espectrometría gamma/métodos , Espectrometría gamma/normas , Espectrometría gamma/estadística & datos numéricos , Incertidumbre
17.
Appl Radiat Isot ; 126: 252-255, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28256377

RESUMEN

The International Atomic Energy Agency organised four proficiency tests between 2012 and 2015 to test the performance of participating laboratories in an analysis of radionuclides in sea water samples. These exercises were initiated to support IAEA Member States in sea water analyses of tritium, strontium-90 and caesium isotopes in relation to the accident at the Fukushima Daiichi nuclear power station, in March 2011, and subsequent contamination of the marine environment.


Asunto(s)
Radiometría/métodos , Agua de Mar/análisis , Contaminantes Radiactivos del Agua/análisis , Animales , Radioisótopos de Cesio/análisis , Accidente Nuclear de Fukushima , Humanos , Agencias Internacionales , Ensayos de Aptitud de Laboratorios/métodos , Ensayos de Aptitud de Laboratorios/estadística & datos numéricos , Mar Mediterráneo , Radiometría/estadística & datos numéricos , Radioisótopos de Estroncio/análisis , Tritio/análisis
18.
Appl Radiat Isot ; 126: 270-272, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28187931

RESUMEN

A radon in drinking water interlaboratory comparison (ILC) was conducted between eight laboratories in Europe. The majority of the measurement results submitted were in agreement with the assigned value, with a single result deemed questionable. The questionable result does not deviate significantly from the assigned value but the measurement uncertainties associated with this result could be too small. The results from this ILC indicate that there is good agreement between participating laboratories for radon in water measurements.


Asunto(s)
Agua Potable/análisis , Radón/análisis , Conteo por Cintilación/métodos , Contaminantes Radiactivos del Agua/análisis , Europa (Continente) , Humanos , Laboratorios , Ensayos de Aptitud de Laboratorios/métodos , Ensayos de Aptitud de Laboratorios/estadística & datos numéricos , Conteo por Cintilación/estadística & datos numéricos
19.
Artículo en Inglés | MEDLINE | ID: mdl-28093042

RESUMEN

Although the use of chloramphenicol (CAP) as a veterinary drug is banned in the European Union and many other countries, monitoring for CAP residues in food is routine. Positive detections are few, but taken extremely seriously. European Union laboratories analysing for CAP should validate methods according to European Commission Decision 2002/657/EC, must be accredited to ISO 17025, and will generally participate in proficiency testing (PT) schemes, such as those offered by the Food Analysis Performance Assessment Scheme (FAPAS®). The FAPAS PTs aim to cover a wide range of relevant matrices including honey, prawns, fish, milk and kidney. Test materials are prepared either by animal dosing studies or by spiking raw matrix. The most common method reported by FAPAS participants used to screen for CAP residues is LC-MS/MS, but ELISA kits are increasingly being used. A recent PT round highlighted that the result obtained might be correlated with the type of analytical method being employed. Follow-up investigations have demonstrated that some of these variations in data are a function of the different stereoisomeric forms of CAP. This paper discusses the implication of this research on method validation requirements and European Union legislation.


Asunto(s)
Antibacterianos/análisis , Cloranfenicol/análisis , Contaminación de Alimentos/análisis , Ensayos de Aptitud de Laboratorios/estadística & datos numéricos , Drogas Veterinarias/análisis , Animales , Antibacterianos/química , Cloranfenicol/química , Cromatografía Líquida de Alta Presión/normas , Control de Medicamentos y Narcóticos/legislación & jurisprudencia , Ensayo de Inmunoadsorción Enzimática/normas , Unión Europea , Peces/metabolismo , Miel/análisis , Humanos , Riñón/química , Leche/química , Estereoisomerismo , Espectrometría de Masas en Tándem/normas , Estudios de Validación como Asunto , Drogas Veterinarias/química
20.
Cytometry B Clin Cytom ; 92(4): 266-274, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-26934069

RESUMEN

BACKGROUND: Paroxysmal nocturnal haemoglobinuria (PNH) is a rare acquired genetic disorder, with an incidence of approximately 1.3 new cases per million population per year. Evidence from the UK National External Quality Assessment Service for Leucocyte Immunophenotyping (UK NEQAS LI) programme suggested major discrepancies on how PNH testing is undertaken. To investigate this we surveyed laboratories in the UK NEQAS LI PNH programme and report here the findings. METHODS: A questionnaire was distributed to all centres registered in UK NEQAS LI flow cytometry programmes (n = 1587). Comprising several subsections, it covered the majority of clinical flow cytometric practices. Participants completed a general section and then the subsections relevant to their laboratory repertoire. One subsection contained 34 questions regarding practices in PNH clone detection. RESULTS: A total of 105 laboratories returned results for the PNH section; the results demonstrated lack of consensus in all areas of PNH testing. Variation was seen in gating and testing strategies, sensitivity levels and final reporting of test results. Several incorrect practices were highlighted such as inappropriate antibody selection and failure to wash the red blood cells (RBCs) prior to analysis. CONCLUSION: Despite the availability of consensus guidelines there appears to be no agreement in the detection and monitoring of PNH. We found only fourteen centres using methods compatible with the International Clinical Cytometry Society guidelines. Of specific note we found that no two laboratories used the same method. This technical variation could lead to incorrect diagnoses, highlighting the need for better adoption and understanding of consensus practices. © 2016 International Clinical Cytometry Society.


Asunto(s)
Citometría de Flujo/normas , Hemoglobinuria Paroxística/diagnóstico , Inmunofenotipificación/normas , Ensayos de Aptitud de Laboratorios/estadística & datos numéricos , Leucocitos/patología , Células Clonales , Hemoglobinuria Paroxística/inmunología , Hemoglobinuria Paroxística/patología , Humanos , Leucocitos/inmunología , Guías de Práctica Clínica como Asunto , Control de Calidad , Encuestas y Cuestionarios , Reino Unido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...