Am J Ophthalmol ; 108(2): 113-7, 1989 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-2502923

RESUMEN

Four patients developed corneal ulcers associated with the use of disposable extended-wear hydrogel contact lenses. Bacteria were recovered from corneal ulcers in three of the patients. Three patients discarded their contact lenses after ten or more days of extended wear; the corneal ulcers in these patients developed toward the end of the wearing cycle. The fourth patient removed her contact lenses every two days for cleaning and disinfection and discarded them for a new pair on a weekly basis. Improper lens hygiene was noted in only one patient. All corneal ulcers responded to antibiotic treatment. In three patients visual acuity returned to normal, but scarring of one patient's cornea resulted in a visual acuity of 20/60.


Asunto(s)
Lentes de Contacto de Uso Prolongado/efectos adversos , Úlcera de la Córnea/etiología , Equipos Desechables/efectos adversos , Polietilenglicoles , Adulto , Infecciones Bacterianas , Femenino , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato , Propionibacterium acnes , Infecciones por Pseudomonas , Pseudomonas aeruginosa , Infecciones Estreptocócicas
2.
JAMA ; 260(14): 2073-6, 1988 Oct 14.
Artículo en Inglés | MEDLINE | ID: mdl-3418871

RESUMEN

In 1986, the Centers for Disease Control, in collaboration with the Health Care Financing Administration, surveyed 1350 chronic hemodialysis centers in the United States to ascertain practices associated with the reuse of disposable hemodialyzers and the frequency of pyrogenic reactions and septicemia among patients. Reuse of hemodialyzers was reported by 63% of the centers. Centers that used RenNew-D (n = 5) for reprocessing hemodialyzers, compared with centers that did not reuse (n = 495), were more likely to report pyrogenic reactions (60% vs 13%) and episodes of septicemia (100% vs 55%) among their patients. Reusing hemodialyzers more than 20 times and, in some instances, also using manual reprocessing systems was significantly associated with clustering of pyrogenic reactions regardless of the type of germicide used. To detect membrane leaks developing after multiple reuses, air-pressure-leak tests should be performed on all reprocessed hemodialyzers.


Asunto(s)
Equipos Desechables , Riñones Artificiales , Desinfectantes , Equipos Desechables/efectos adversos , Formaldehído , Hepatitis B/epidemiología , Humanos , Riñones Artificiales/efectos adversos , Vigilancia de la Población , Pirógenos , Diálisis Renal/efectos adversos , Diálisis Renal/instrumentación , Sepsis/epidemiología , Agrupamiento Espacio-Temporal , Estados Unidos
3.
JAMA ; 260(14): 2077-81, 1988 Oct 14.
Artículo en Inglés | MEDLINE | ID: mdl-3418872

RESUMEN

We investigated 18 pyrogenic reactions (PRs) that occurred between July 1 and 13, 1987, in 16 patients receiving long-term hemodialysis at one dialysis center in Illinois. We defined a case of PR as the onset of chills or fever (oral temperature, greater than or equal to 37.8 degrees C) in a patient who was afebrile and had no signs or symptoms of infection before a dialysis treatment. Pyrogenic reactions to dialysis sessions during the epidemic period (July 1 through 14) were associated with the use of a reused dialyzer (risk ratio, 6.2; 95% confidence interval, 0.8 to 45). The water used to rinse the dialyzers after use and to dilute the germicide for disinfecting the dialyzers contained high concentrations of endotoxins (greater than 6 ng/mL) and bacteria (greater than 10(4) colony forming units/mL). After reuse of dialyzers was discontinued at the center, the PR rate fell to pre-epidemic levels. We concluded that PRs were associated with reuse of dialyzers, probably contaminated with endotoxins. Active surveillance for PRs among patients undergoing long-term hemodialysis should be routine at all dialysis centers; an increase in PRs should prompt timely review of water treatment and dialyzer reprocessing systems.


Asunto(s)
Equipos Desechables/efectos adversos , Contaminación de Equipos , Fiebre/etiología , Riñones Artificiales/efectos adversos , Pirógenos , Bacterias/aislamiento & purificación , Brotes de Enfermedades , Desinfección/métodos , Endotoxinas/aislamiento & purificación , Métodos Epidemiológicos , Contaminación de Equipos/prevención & control , Humanos , Illinois , Microbiología del Agua
7.
Radiology ; 122(3): 577-9, 1977 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-841092

RESUMEN

Recent government directives and manufacturers' warnings have strongly cautioned against reuse of angiographic catheters and guide wires following cleaning and sterilization. Though it is theoretically possible that complications might result from reuse, actual documentation is lacking. Complete sterility can be achieved by standard procedures even when the devices are intentionally infected. Survey data indicate no increased incidence of mechanical malfunction when these devices are reused.


Asunto(s)
Angiografía/instrumentación , Cateterismo/instrumentación , Equipos Desechables , Angiografía/efectos adversos , Cateterismo/efectos adversos , Equipos Desechables/efectos adversos , Riesgo , Esterilización/métodos
8.
Ann Surg ; 180(6): 831-5, 1974 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-4611359

RESUMEN

Two patients with postoperative granulomatous peritonitis were found to have lesions with a distinctive type of foreign body. Laboratory investigation revealed this foreign body to be cellulose, morphologically identical with fibers derived from disposable surgical gowns and drapes, and cotton. The same type of foreign body granulomas was produced experimentally by introducing lint prepared from these gowns and drapes into the peritoneal cavities of rats. Since disposable gowns and drapes are being used with increasing frequency, cellulose lint derived from these sources should be added to the list of hazardous foreign materials which are potential wound contaminants.


Asunto(s)
Celulosa/efectos adversos , Equipos Desechables/efectos adversos , Reacción a Cuerpo Extraño , Granuloma de Células Gigantes/etiología , Peritonitis/etiología , Equipo Quirúrgico/efectos adversos , Adolescente , Adulto , Animales , Femenino , Reacción a Cuerpo Extraño/patología , Granuloma de Células Gigantes/patología , Humanos , Masculino , Peritoneo/patología , Peritonitis/patología , Ratas