Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biomed Chromatogr ; 35(11): e5203, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34145610

RESUMEN

An accurate and sensitive UPLC-MS/MS method was developed and validated for the simultaneous estimation of the newly developed combination of sacubitril and valsartan and the co-administered drugs nebivolol, chlorthalidone and esomeprazole in human plasma. Solid-phase extraction was conducted for the purification and extraction of the drugs from human plasma. Chromatographic separation was carried out on an Agilent SB-C18 (1.8 µm, 2.1 × 50 mm) column using losartan as internal standard. Isocratic elution was applied using acetonitrile-0.1% formic acid in water (85: 15, v/v) as mobile phase. Detection was carried out using a triple-quadrupole tandem mass spectrometer using multiple reaction monitoring, at positive mode at m/z 412.23 → 266.19 for sacubitril, m/z 436.29 → 235.19 for valsartan, m/z 405.8 → 150.98 for nebivolol, m/z 346.09 → 198 for esomeprazole and a selected combination of two fragments m/z 423.19 → 207.14 and 423.19 → 192.2 for losartan (internal standard), and in negative ionization mode at m/z 337.02 → 190.12 for chlorthalidone. The method was linear over the concentration ranges 30-2,000 ng/ml for sacubitril, 70-2,000 ng/ml for valsartan, esomeprazole and chlorthalidone and 70-5,000 pg/ml for nebivolol. The developed method is sensitive and selective and could be applied for dose adjustment, bioavailability and drug-drug interaction studies.


Asunto(s)
Aminobutiratos/sangre , Compuestos de Bifenilo/sangre , Cromatografía Líquida de Alta Presión/métodos , Extracción en Fase Sólida/métodos , Espectrometría de Masas en Tándem/métodos , Valsartán/sangre , Aminobutiratos/administración & dosificación , Aminobutiratos/aislamiento & purificación , Compuestos de Bifenilo/administración & dosificación , Compuestos de Bifenilo/aislamiento & purificación , Clortalidona/administración & dosificación , Clortalidona/sangre , Clortalidona/aislamiento & purificación , Combinación de Medicamentos , Estabilidad de Medicamentos , Esomeprazol/administración & dosificación , Esomeprazol/sangre , Esomeprazol/aislamiento & purificación , Humanos , Límite de Detección , Modelos Lineales , Nebivolol/administración & dosificación , Nebivolol/sangre , Nebivolol/aislamiento & purificación , Reproducibilidad de los Resultados , Valsartán/administración & dosificación , Valsartán/aislamiento & purificación
2.
PLoS One ; 15(8): e0236297, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32780750

RESUMEN

Naproxen is a widely used non-steroidal anti-inflammatory drug for the control of postoperative inflammatory signs and symptoms in dentistry. Its association with esomeprazole has been widely studied and has yielded good results for the control of acute pain, even with the delayed absorption of naproxen owing to the presence of esomeprazole. To further understand the absorption, distribution, and metabolism of this drug alone and in combination with esomeprazole, we will analyze the pharmacokinetic parameters of naproxen and its major metabolite, 6-O-desmethylnaproxen, in saliva samples. A rapid, sensitive, and selective liquid chromatography-tandem mass spectrometric method for the simultaneous determination of naproxen and 6-O-desmethylnaproxen in saliva will be developed and validated. Sequential saliva samples from six patients will be analyzed before and 0.25, 0.5, 0.75, 1, 1.5, 2, 3, 4, 5, 6 8, 11, 24, 48, 72, and 96 h after the ingestion of one naproxen tablet (500 mg) and esomeprazole-associated naproxen tablets (500 + 20 mg), at two different times. After liquid-liquid extraction with ethyl acetate and HCl, the samples will be analyzed using an 8040 Triple Quadrupole Mass Spectrometer (Shimadzu, Kyoto, Japan). Separation of naproxen and its major metabolic products will be performed using a Shim-Pack XR-ODS 75Lx2.0 column and C18 pre-column (Shimadzu, Kyoto, Japan) at 40°C using a mixture of methanol and 10 mM ammonium acetate (70:30, v/v) with an injection flow of 0.3 mL/min. The total analytical run time will be 5 min. The detection and quantification of naproxen and its metabolite will be validated, which elucidate the pharmacokinetics of this drug, thereby contributing to its proper prescription for the medical and dental interventions that cause acute pain.


Asunto(s)
Antiinflamatorios no Esteroideos/farmacocinética , Monitoreo de Drogas/métodos , Esomeprazol/farmacocinética , Naproxeno/análogos & derivados , Saliva/química , Administración Oral , Adolescente , Adulto , Antiinflamatorios no Esteroideos/aislamiento & purificación , Cromatografía Líquida de Alta Presión/métodos , Relación Dosis-Respuesta a Droga , Combinación de Medicamentos , Esomeprazol/administración & dosificación , Esomeprazol/aislamiento & purificación , Femenino , Absorción Gastrointestinal , Humanos , Masculino , Metanol/química , Persona de Mediana Edad , Naproxeno/administración & dosificación , Naproxeno/aislamiento & purificación , Naproxeno/farmacocinética , Dolor Asociado a Procedimientos Médicos/tratamiento farmacológico , Reproducibilidad de los Resultados , Comprimidos , Espectrometría de Masas en Tándem/métodos , Adulto Joven
3.
J Sep Sci ; 43(4): 696-707, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31724311

RESUMEN

An updated and improved method for analysis of omeprazole/esomeprazole and related substances on core-shell columns was developed using Fusion LC Method Development™. The method was optimized with respect to column type, column temperature, mobile phase pH level, and gradient time. Four different core-shell columns were examined to develop a method suitable for both high performance- and ultra-high performance liquid chromatography using a Quality by Design approach. The final method offers two alternative columns: Poroshell EC C18 (3.0 × 100 mm, 2.7 µm) or Poroshell HPH (3.0 × 100 mm, 2.7 µm) with the same gradient elution condition and mobile phase composition. Total run time is 18 min with 12 min of gradient elution. Phosphate buffer (15 mM, pH 7.8) is selected as the aqueous mobile phase and acetonitrile as the organic mobile phase. Column temperature is set at 40°C and ultraviolet detection at 302 nm. Furthermore, by studying parameters in a systematic way, an understanding of the effect of the input parameters enhances the method robustness and should allow for regulatory flexibility in terms of post-approval changes. Compared to the current United States Pharmacopeia method, the updated method is faster, more efficient and performs well above acceptance criteria.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Esomeprazol/aislamiento & purificación , Omeprazol/aislamiento & purificación , Cromatografía Líquida de Alta Presión/instrumentación , Esomeprazol/análisis , Omeprazol/análisis , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...