Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.715
Filtrar
1.
J Cardiothorac Surg ; 19(1): 196, 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38600556

RESUMEN

BACKGROUND: The transcarotid (TC) vascular access for transcatheter aortic valve implantation (TAVI) has emerged as the first-choice alternative to the transfemoral access, in patients unsuitable for the latter. The use of both the left and right common carotid arteries (CCAs) for TC-TAVI has been described, but the optimal side is subject to debate. We conducted this pilot study to compare the level of vessel tortuosity and plaque burden from either the left CCA to the aortic annulus, or the right CCA to the aortic annulus, considering them as surrogates for technical and procedural complexity. METHODS: Consecutive patients who underwent TC-TAVI between 2018 and 2021 in our institution were included. Using three-dimensional reconstruction, pre-TAVI neck and chest computed tomography angiography exams were reviewed to assess the tortuosity index (TI), sum of angles metric, as well as plaque burden, between each CCA and the aortic annulus. RESULTS: We included 46 patients who underwent TC-TAVI. No significant difference regarding the mean TIs between the left and right sides (respectively 1.20 and 1.19, p = 0.82), the mean sum of angles (left side: 396°, right side: 384°, p = 0.27), and arterial plaque burden (arterial plaque found in 30% of left CCAs and 45% of right CCAs, p = 0.19) was found. CONCLUSIONS: We found no convincing data favoring the use of one particular access side over the other one. The choice of the CCA side in TC-TAVI should to be made on a case-by-case basis, in a multidisciplinary fashion, and may also depend on the operators' experience.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Proyectos Piloto , Arteria Carótida Común/cirugía , Resultado del Tratamiento
2.
J Cardiothorac Surg ; 19(1): 192, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38594705

RESUMEN

BACKGROUND: Perceval-S has become a reliable and commonly used option in surgical aortic valve replacement (AVR) since its first implantation in humans 15 years ago. Despite the fact that this aortic valve has been proven efficient enough in the short and mid-term period, there is still lack of evidence for the long-term outcomes. MATERIALS AND METHODS: This is an observational retrospective study in a high-volume cardiovascular center. Pertinent data were collected for all the patients in whom Perceval-S was implanted from 2013 to 2020. RESULTS: The total number of patients was 205 with a mean age 76.4 years. Mean survival time was 5.5 years (SE = 0.26). The overall survival probability of patients undergoing aortic valve replacement with Perceval-S at 6 months was 91.0% (Standard Error SE = 2.0%), at one year 88.4% (SE = 2.3%) and at 5-years 64.8% (SE = 4.4%). A detrimental cardiac event leading to death was the probable cause of death in 35 patients (55.6%). The initiation of Transcatheter Aortic Valve Replacement (TAVR) program in our center in 2017 was associated with a decline in the number of very high-risk patients treated with sutureless bioprosthesis. This fact is demonstrated by the significant shift towards lower surgical risk cases, as median Euroscore II was reduced from 5,550 in 2016 to 3,390 in 2020. Mini sternotomy was implemented in 79,5% of cases favoring less invasive approach. Low incidence of reinterventions, patient prosthesis mismatch and structural valve degeneration was detected. CONCLUSIONS: The survival rate after aortic valve replacement with implantation of Perceval-S is satisfactory in the long-term follow-up. Cases of bioprosthesis dysfunction were limited. Mini sternotomy was used in the majority of cases. TAVR initiation program impacted on the proportion of patients treated with Perceval-S with reduction of high-risk patients submitted to surgery.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Anciano , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Estudios Retrospectivos , Diseño de Prótesis , Válvula Aórtica/cirugía , Resultado del Tratamiento
3.
J Cardiovasc Med (Hagerstown) ; 25(4): 259-270, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38488063

RESUMEN

Aortic stenosis is the most prevalent valvular heart disease requiring intervention, especially in the elderly population. Surgical aortic valve replacement and transcatheter aortic valve implantation (TAVI) are well established treatment options for symptomatic patients with severe aortic stenosis, as they provide a significant survival benefit. Aortic stenosis may have an important impact on patients' quality of life (QoL). However, advanced age, comorbidities and frailty may limit the beneficial effect of aortic stenosis interventions in terms of QoL. Current guidelines mention the importance of frailty and avoiding the futility of interventions, but lack specific indications about decision-making. Also, there are limited data on how to specifically assess QoL in aortic stenosis patients since the most used questionnaires are validated in different populations (i.e. heart failure). The aim of this review is to summarize all the available tools for QoL assessment in patients with aortic stenosis; to report current evidence on the impact of TAVI on QoL; and to discuss the role of frailty and comorbidities in this setting.


Asunto(s)
Estenosis de la Válvula Aórtica , Fragilidad , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Calidad de Vida , Fragilidad/complicaciones , Fragilidad/diagnóstico , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Resultado del Tratamiento , Factores de Riesgo , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
4.
Catheter Cardiovasc Interv ; 103(5): 808-814, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38461377

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a reasonable therapeutic approach among patients with symptomatic severe aortic stenosis irrespective of surgical risk. Data regarding sex-specific differences in the outcomes with newer generation valves are limited. METHODS: Electronic databases were searched for studies assessing sex differences in the outcomes of patients undergoing TAVR with newer generation valves (SAPIEN 3 or Evolut). Random effects model was constructed for summary estimates. RESULTS: Four observational studies with 4522 patients (44.8% women) were included in the meta-analysis. Women were older and had a lower prevalence of coronary artery disease and mean EuroScore. Women had a higher incidence of short-term mortality (up to 30 days) (risk ratio [RR]: 1.60, 95% confidence interval [CI]: 1.14-2.25), but no difference in 1-year mortality (RR: 0.92, 95% CI: 0.72-1.17). There was no significant difference in the incidence of major bleeding (RR: 1.16, 95% CI: 0.86-1.57), permanent pacemaker (PPM) (RR: 0.80, 95% CI: 0.62-1.04), or disabling stroke (RR: 1.16, 95% CI: 0.54-2.45). CONCLUSION: In this meta-analysis, we found that women undergoing TAVR with newer-generation devices were older but had a lower prevalence of comorbidities. Women had a higher incidence of short-term mortality but no difference in the 1-year mortality, bleeding, PPM, or stroke compared with men. Future studies are required to confirm these findings.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Femenino , Humanos , Masculino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Hemorragia/etiología , Factores de Riesgo , Caracteres Sexuales , Accidente Cerebrovascular/etiología , Resultado del Tratamiento
5.
J Am Heart Assoc ; 13(7): e033176, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38533939

RESUMEN

BACKGROUND: It remains controversial whether prosthesis-patient mismatch (PPM) impacts long-term outcomes after surgical aortic valve replacement. We aimed to evaluate the association of PPM with mortality, rehospitalizations, and aortic valve reinterventions. METHODS AND RESULTS: We performed a systematic review with meta-analysis of reconstructed time-to-event data of studies published by March 2023 (according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses). Sixty-five studies met our eligibility criteria and included 122 989 patients (any PPM: 68 332 patients, 55.6%). At 25 years of follow-up, the survival rates were 11.8% and 20.6% in patients with and without any PPM, respectively (hazard ratio [HR], 1.16 [95% CI, 1.13-1.18], P<0.001). At 20 years of follow-up, the survival rates were 19.5%, 12.1%, and 8.8% in patients with no, moderate, and severe PPM, respectively (moderate versus no PPM: HR, 1.09 [95% CI, 1.06-1.11], P<0.001; severe versus no PPM: HR, 1.29 [95% CI, 1.24-1.35], P<0.001). PPM was associated with higher risk of cardiac death, heart failure-related hospitalizations, and aortic valve reinterventions over time (P<0.001). Statistically significant associations between PPM and worse survival were observed regardless of valve type (bioprosthetic versus mechanical valves), contemporary PPM definitions unadjusted and adjusted for body mass index, and PPM quantification method (in vitro, in vivo, Doppler echocardiography). Our meta-regression analysis revealed that populations with more women tend to have higher HRs for all-cause death associated with PPM. CONCLUSIONS: The results of the present study suggest that any degree of PPM is associated with poorer long-term outcomes following surgical aortic valve replacement and provide support for implementation of preventive strategies to avoid PPM after surgical aortic valve replacement.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Femenino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Falla de Prótesis , Resultado del Tratamiento , Prótesis Valvulares Cardíacas/efectos adversos , Factores de Riesgo , Diseño de Prótesis
6.
Open Heart ; 11(1)2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38538065

RESUMEN

OBJECTIVE: A paucity of data exists on how transcatheter aortic valve implantation (TAVI) practice has evolved in Ireland. This study sought to analyse temporal trends in patient demographics, procedural characteristics, and clinical outcomes at an Irish tertiary referral centre. METHODS: The prospective Mater TAVI database was divided into time tertiles based on when TAVI was performed: Group A, November 2008-April 2013; Group B, April 2013-September 2017; and Group C, September 2017-February 2022. Patient and procedural characteristics and clinical outcomes were compared across groups. RESULTS: A total of 1063 (Group A, 59; Group B, 268; and Group C:, 736) patients were treated with TAVI during the study period (mean age 81.1±7.4, mean Society of Thoracic Surgeons score 5.9±5.1).Conscious sedation (Group A, 0%; Group B, 59.9%; and Group C, 90.2%, p<0.001) and femoral artery access (Group A, 76.3%; Group B, 90.7%; and Group C, 96.6%, p<0.001) were used more frequently over time. The median length of hospital stay reduced from 9 days (IQR 7, 18) in Group A to 2 days (IQR 2, 3) in Group C. In-hospital death was numerically higher in Group A compared with Group C (6.8% vs 1.9%, p=0.078). At 1-year follow-up, the rate of death and/or stroke was similar in Group A and Group C (20.3% vs 12.0%, adjusted HR 1.49, 95% CI (0.59 to 3.74)). CONCLUSION: There was exponential growth in TAVI procedural volume during the study period. A minimalist approach to TAVI emerged, and this was associated with significantly shorter procedure duration and hospital stay. Clinical outcomes at 1-year follow-up did not change significantly over time.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Estudios Prospectivos , Centros de Atención Terciaria , Mortalidad Hospitalaria , Resultado del Tratamiento
7.
Catheter Cardiovasc Interv ; 103(3): 490-498, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38329195

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has changed the landscape of aortic stenosis (AS) management. AIM: To describe and evaluate geographic variation in AS treatment and outcomes among a sample of Medicare beneficiaries. METHODS: A retrospective analysis of administrative claims data was conducted on a 20% sample of Medicare fee-for-service beneficiaries aged 65 and older with a diagnosis of AS (2015-2018). Estimates of demographic, comorbidity, and healthcare resources were obtained from Medicare claims and the Dartmouth Atlas of Health Care at the hospital referral region (HRR), which represents regional tertiary medical care markets. Linear regression was used to explain HRR-level variation in rates of surgical aortic valve replacement (SAVR) and TAVR, and 1-year mortality and readmission rates. RESULTS: A total of 740,899 beneficiaries with AS were identified with a median prevalence of AS of 39.9 per 1000 Medicare beneficiary years. The average HRR-level rate of SAVR was 26.3 procedures per 1000 beneficiary years and the rate of TAVR was 20.3 procedures per 1000 beneficiary years. HRR-level comorbidities and number of TAVR centers were associated with a lower SAVR rate. Demographics and comorbidities explained most of the variation in HRR-level 1-year mortality (15.2% and 18.8%) and hospitalization rates (20.5% and 16.9%), but over half of the variation remained unexplained. CONCLUSION: Wide regional variation in the treatment and outcomes of AS was observed but were largely unexplained by patient factors and healthcare utilization. Understanding the determinants of AS treatment and outcomes can inform population health efforts for these patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Estados Unidos/epidemiología , Medicare , Estudios Retrospectivos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Constricción Patológica , Factores de Riesgo
8.
JACC Cardiovasc Interv ; 17(4): 505-515, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38340102

RESUMEN

BACKGROUND: A single, multitiered valve center designation has been proposed to publicly identify centers with expertise for all valve therapies. The correlation between transcatheter aortic valve replacement (TAVR) and mitral transcatheter edge-to-edge repair (MTEER) procedures is unknown. OBJECTIVES: The authors sought to examine the relationship between site-level volumes and outcomes for TAVR and MTEER. We further explored variability between sites for MTEER outcomes. METHODS: Using the STS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) national registry, TAVR and MTEER procedures at sites offering both therapies from 2013 to 2022 were examined. Sites were ranked into deciles of adjusted in-hospital and 30-day outcomes separately for TAVR and MTEER and compared. Stepwise, hierarchical multivariable models were constructed for MTEER outcomes, and the median OR was calculated. RESULTS: Between 2013 and 2022, 384,394 TAVRs and 53,274 MTEERs (median annualized volumes: 93.6 and 18.8, respectively) were performed across 453 U.S. sites. Annualized TAVR and MTEER volumes were moderately correlated (r = 0.48; P < 0.001). After adjustment, 14.3% of sites had the same decile rank for TAVR and MTEER 30-day composite outcome, 50.6% were within 2 decile ranks; 35% had more discordant outcomes for the 2 procedures (P = 0.0005). For MTEER procedures, the median OR for the 30-day composite outcome was 1.57 (95% CI: 1.51-1.64), indicating a 57% variability in outcome by site. CONCLUSIONS: There is modest correlation between hospital-level volumes for TAVR and MTEER but low interprocedural correlation of outcomes. For similar patients, site-level variability for mortality/morbidity following MTEER was high. Factors influencing outcomes and "centers of excellence" as a whole may differ for TAVR and MTEER.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estados Unidos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Resultado del Tratamiento , Sistema de Registros , Hospitales , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Factores de Riesgo
9.
J Am Heart Assoc ; 13(5): e033768, 2024 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-38390797

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has seen indication expansion and thus exponential growth in demand over the past decade. In many jurisdictions, the growing demand has outpaced capacity, increasing wait times and preprocedural adverse events. In this study, we derived prediction models that estimate the risk of adverse events on the waitlist and developed a triage tool to identify patients who should be prioritized for TAVI. METHODS AND RESULTS: We included adult patients in Ontario, Canada referred for TAVI and followed up until one of the following events first occurred: death, TAVI procedure, removal from waitlist, or end of the observation period. We used subdistribution hazards models to find significant predictors for each of the following outcomes: (1) all-cause death while on the waitlist; (2) all-cause hospitalization while on the waitlist; (3) receipt of urgent TAVI; and (4) a composite outcome. The median predicted risk at 12 weeks was chosen as a threshold for a maximum acceptable risk while on the waitlist and incorporated in the triage tool to recommend individualized wait times. Of 13 128 patients, 586 died while on the waitlist, and 4343 had at least 1 hospitalization. A total of 6854 TAVIs were completed, of which 1135 were urgent procedures. We were able to create parsimonious models for each outcome that included clinically relevant predictors. CONCLUSIONS: The Canadian TAVI Triage Tool (CAN3T) is a triage tool to assist clinicians in the prioritization of patients who should have timely access to TAVI. We anticipate that the CAN3T will be a valuable tool as it may improve equity in access to care, reduce preventable adverse events, and improve system efficiency.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Listas de Espera , Triaje , Resultado del Tratamiento , Ontario , Válvula Aórtica/cirugía , Factores de Riesgo
10.
Sci Adv ; 10(9): eadj9793, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38416823

RESUMEN

In calcific aortic valve disease (CAVD), mechanosensitive valvular cells respond to fibrosis- and calcification-induced tissue stiffening, further driving pathophysiology. No pharmacotherapeutics are available to treat CAVD because of the paucity of (i) appropriate experimental models that recapitulate this complex environment and (ii) benchmarking novel engineered aortic valve (AV)-model performance. We established a biomaterial-based CAVD model mimicking the biomechanics of the human AV disease-prone fibrosa layer, three-dimensional (3D)-bioprinted into 96-well arrays. Liquid chromatography-tandem mass spectrometry analyses probed the cellular proteome and vesiculome to compare the 3D-bioprinted model versus traditional 2D monoculture, against human CAVD tissue. The 3D-bioprinted model highly recapitulated the CAVD cellular proteome (94% versus 70% of 2D proteins). Integration of cellular and vesicular datasets identified known and unknown proteins ubiquitous to AV calcification. This study explores how 2D versus 3D-bioengineered systems recapitulate unique aspects of human disease, positions multiomics as a technique for the evaluation of high throughput-based bioengineered model systems, and potentiates future drug discovery.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Válvula Aórtica/patología , Calcinosis , Humanos , Válvula Aórtica/química , Válvula Aórtica/metabolismo , Proteómica , Proteoma/metabolismo , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/metabolismo , Células Cultivadas
11.
J Am Heart Assoc ; 13(4): e033289, 2024 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-38362873

RESUMEN

BACKGROUND: The management of mixed aortic valve disease (MAVD), defined as the concomitant presence of aortic stenosis (AS) and aortic regurgitation, remains a clinical challenging. The present study assessed the impact of transcatheter aortic valve replacement (TAVR) on cardiac geometry and prognosis in patients with MAVD. METHODS AND RESULTS: A retrospective multicenter TAVR registry was conducted, including patients who underwent TAVR for severe symptomatic AS between January 2015 and March 2019. Patients were subdivided into 2 groups according to concomitant presence of moderate or more severe aortic regurgitation as the MAVD group, and with mild or less severe aortic regurgitation as the isolated AS group. The primary outcome was a composite of cardiovascular death and rehospitalization due to cardiovascular causes. A total of 1742 patients (isolated AS, 1522 patients; MAVD, 220 patients) were included (84.0±5.2 years). Although MAVD exhibited significantly larger left ventricular volumes and higher left ventricular mass index at the TAVR procedure than isolated AS (respectively, P<0.001), MAVD showed a greater improvement of left ventricular volumes and left ventricular mass index after TAVR (respectively, P≤0.001). During a median follow-up of 747 days, 301 patients achieved the primary event. The prognosis post-TAVR was comparable between the 2 groups (log-rank P=0.65). Even after adjustment using propensity score matching to reduce the potential bias between the 2 groups, similar results were obtained for the entire cohort. CONCLUSIONS: Despite more advanced cardiac remodeling in MAVD at the time of TAVR compared with isolated AS, a greater improvement of cardiac reverse remodeling was found in MAVD, and the prognosis following TAVR was comparable between the 2 groups.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Resultado del Tratamiento , Factores de Riesgo , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Pronóstico , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Función Ventricular Izquierda
13.
J Cardiovasc Med (Hagerstown) ; 25(4): 327-333, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38358902

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has become a largely used treatment for severe aortic stenosis. There are limited data, however, about predictors of long-term prognosis in this population. In this study, we assessed whether ventricular arrhythmias may predict clinical outcomes in patients undergoing TAVI. METHODS AND RESULTS: We performed a 24 h ECG Holter monitoring in 267 patients who underwent TAVI for severe aortic stenosis within 30 days from a successful procedure. The occurrence of frequent premature ventricular complexes (PVCs; ≥30/h), polymorphic PVCs and nonsustained ventricular tachycardia (NSVT) was obtained for each patient. Clinical outcome was obtained for 228 patients (85%), for an average follow-up of 3.5 years (range 1.0-8.6). Cardiovascular events (CVEs; cardiovascular death or resuscitated cardiac arrest) occurred in 26 patients (11.4%) and 63 patients died (27.6%). Frequent PVCs but not polymorphic PVCs and NSVT were found to be associated with CVEs at univariate analysis. Frequent PVCs were indeed found in 12 patients with (46.2%) and 35 without (17.3%) CVEs [hazard ratio 2.30; 95% confidence interval (CI) 1.03-5.09; P  = 0.04], whereas polymorphic PVCs were found in 11 (42.3%) and 54 (26.7%) patients of the two groups, respectively (hazard ratio 1.44; 95% CI 0.64-3.25; P  = 0.38), and NSVT in 9 (34.6%) and 43 patients of the two groups, respectively (hazard ratio 1.18; 95% CI 0.48-2.87; P  = 0.72). Frequent PVCs, however, were not significantly associated with CVEs at multivariate Cox regression analysis (hazard ratio 1.53; 95% CI 0.37-6.30; P  = 0.56). Both frequent PVCs, polymorphic PVCs and NSVT showed no significant association with mortality. CONCLUSION: In our study, the detection of frequent PVCs at Holter monitoring after TAVI was a predictor of CVEs (cardiovascular death/cardiac arrest), but this association was lost in multivariable analysis.


Asunto(s)
Estenosis de la Válvula Aórtica , Paro Cardíaco , Taquicardia Ventricular , Reemplazo de la Válvula Aórtica Transcatéter , Complejos Prematuros Ventriculares , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/epidemiología , Complejos Prematuros Ventriculares/etiología , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/epidemiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Paro Cardíaco/diagnóstico , Paro Cardíaco/etiología , Paro Cardíaco/terapia , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
15.
J Cardiothorac Surg ; 19(1): 95, 2024 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-38355617

RESUMEN

BACKGROUND: Rapid-deployment aortic valve replacement (RDAVR) is an alternative to conventional AVR (cAVR) for aortic stenosis. Benefits include a reduction in operative times, facilitation of minimal access surgery and superior haemodynamics compared to conventional valves. However, further evidence is required to inform guidelines, preferably in the form of propensity-matched studies that include mid-term follow-up data. METHODS: This was a single-centre, retrospective, propensity-matched cohort study comparing the Perceval and conventional Perimount Magna Ease valve for short- and mid-term clinical parameters and size-matched mid-term echocardiographic parameters (n = 102 in both groups) from 2014 to 2020. Data were extracted from a nationally managed dataset. RESULTS: There were no demographic differences between the matched groups. The Perceval group had shorter cross-clamp time (Perceval 62 [49-81] minutes; Perimount 79 [63-102] minutes, P < 0.001), shorter bypass time (Perceval 89 [74-114] minutes; Perimount 104 [84-137] minutes, P < 0.001), and more frequent minimally-invasive approaches (Perceval 28%; Perimount 5%, P < 0.001). Size-matched haemodynamics showed initially higher gradients in the Perceval group, but haemodynamics equalised at 12 + months. The Perceval group had a more favourable % change in the left ventricular posterior wall dimension at 2 + years (Perceval - 4.8 ± 18; Perimount 17 ± 2). CONCLUSIONS: The Perceval facilitated shorter operations, which may benefit intermediate-high-risk, elderly patients with comorbidities requiring concomitant procedures. It also facilitated minimally invasive surgery. Size-matched haemodynamic performance was similar at mid-term follow-up, with the Perceval possibly better facilitating regression of left ventricular hypertrophy.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Anciano , Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Estudios Retrospectivos , Estudios de Cohortes , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Diseño de Prótesis , Prótesis Valvulares Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología
16.
J Cardiothorac Surg ; 19(1): 3, 2024 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-38167451

RESUMEN

BACKGROUND: This study examined the characteristics and outcomes of surgical aortic valve replacement (SAVR) both isolated and in combination with other cardiac surgery in Malaysia from 2015 to 2021. METHODS: This was a retrospective study of 1346 patients analyzed on the basis of medical records, echocardiograms and surgical reports. The overall sample was both considered as a whole and divided into aortic stenosis (AS)/aortic regurgitation (AR)-predominant and similar-severity subgroups. RESULTS: The most common diagnosis was severe AS (34.6%), with the 3 most common etiologies being bicuspid valve degeneration (45.3%), trileaflet valve degeneration (36.3%) and rheumatic valve disease (12.2%). The second most common diagnosis was severe AR (25.5%), with the most common etiologies being root dilatation (21.0%), infective endocarditis (IE) (16.6%) and fused prolapse (12.2%). Rheumatic valve disease was the most common mixed disease. A total of 54.5% had AS-predominant pathology (3 most common etiologies: bicuspid valve degeneration valve, degenerative trileaflet valve and rheumatic valve disease), 36.9% had AR-predominant pathology (top etiologies: root dilatation, rheumatic valve disease and IE), and 8.6% had similar severity of AS and AR. Overall, 62.9% of patients had trileaflet valve morphology, 33.3% bicuspid, 0.6% unicuspid and 0.3% quadricuspid. For AS, the majority were high-gradient severe AS (49.9%), followed by normal-flow low-gradient (LG) severe AS (10.0%), paradoxical low-flow (LF)-LG severe AS (6.4%) and classical LF-LG severe AS (6.1%). The overall in-hospital and total 1-year mortality rates were 6.4% and 14.8%, respectively. Pure severe AS had the highest mortality. For AS-predominant pathology, the etiology with the highest mortality was trileaflet valve degeneration; for AR-predominant pathology, it was dissection. The overall survival probability at 5 years was 79.5% in all patients, 75.7% in the AS-predominant subgroup, 83.3% in the AR-predominant subgroup, and 87.3% in the similar-severity subgroup. CONCLUSIONS: The 3 most common causes of AS- predominant patients undergoing SAVR is bicuspid valve degeneration, degenerative trileaflet valve and rheumatic and for AR-predominant is root dilatation, rheumatic and IE. Rheumatic valve disease is an important etiology in our SAVR patients especially in mixed aortic valve disease. Study registration IJNREC/562/2022.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Endocarditis Bacteriana , Endocarditis , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Cardiopatía Reumática , Humanos , Válvula Aórtica/cirugía , Válvula Aórtica/patología , Estudios Retrospectivos , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/etiología , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Endocarditis Bacteriana/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Hemodinámica , Cardiopatía Reumática/complicaciones , Cardiopatía Reumática/cirugía , Endocarditis/cirugía , Endocarditis/complicaciones
17.
Circ J ; 88(4): 559-567, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-37019644

RESUMEN

BACKGROUND: Studies of the influence of smaller body type on the severity of prosthesis-patient mismatch (PPM) after small-sized surgical aortic valve replacement (SAVR) are few, but the issue is particularly relevant for Asian patients.Methods and Results: 695 patients who underwent SAVR with bioprosthetic valves had their hemodynamic valve performance analyzed at 3 months, 1 year, 3 years, and 5 years after operation, and clinical outcomes were assessed. The patients were stratified into 3 valve size groups: 19/21, 23, and 25/27 mm. A smaller valve was associated with higher mean pressure gradients at the 4 time points after operation (P trend <0.05). However, the 3 valve size groups demonstrated no significant differences in the risk of clinical events. At none of the time points did patients with projected PPM show increased mean pressure gradients (P>0.05), whereas patients with measured PPM did (P<0.05). Compared with patients with projected PPM, those with measured PPM demonstrated higher rates of infective endocarditis readmission (adjusted hazard ratio [aHR] 3.31, 95% confidence interval [CI] 1.06-10.39) and a higher risk of composite outcomes (aHR 1.45, 95% CI 0.95-2.22, P=0.087). CONCLUSIONS: Relative to those receiving larger valves, patients receiving small bioprosthetic valves had poorer hemodynamic performance but did not demonstrate differences in clinical events in long-term follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios de Seguimiento , Estenosis de la Válvula Aórtica/etiología , Resultado del Tratamiento , Prótesis Valvulares Cardíacas/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Diseño de Prótesis , Hemodinámica
19.
Int J Cardiol ; 399: 131637, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38065322

RESUMEN

BACKGROUND: International guidelines for the management of valvular heart disease recommend frailty assessment prior to Transcatheter Aortic Valve Implantation (TAVI), however there is no consensus how to assess frailty. We investigated whether frailty status assessed with the Edmonton Frail Scale (EFS, range 0-17 points) relates to length of stay (LOS), short- and long-term mortality and adverse outcomes after TAVI. METHODS: In this study we included 357 patients between April 2016 till December 2018. EFS was assessed at baseline. Patients were classified into low (0-3), intermediate (4-7) or high frailty status (8-17). LOS was defined as the number of days between admission and discharge. Mortality data were obtained up to four years after TAVI. Adverse events were defined by Valve Academic Research Consortium (VARC)-2 criteria and collected <30 days after TAVI. RESULTS: Patients with higher frailty status had longer median LOS (days (IQR): low 5 (3), intermediate 6 (4) and high 7 (5), p < 0.001) and higher mortality: low vs intermediate vs high at 30 days 0.5%, 2.2%, 7.0% (p = 0.050), 1 year 3.7%, 10.0%, 15.2% (p = 0.052), 2 years 9.2%, 17.8%, 31.7% (p = 0.003), 3 years 17.2%, 24.0, 47.0% (p = 0.001) and 4 years 19.6%, 30.8%, 55.6% (p < 0.001). Frail patients received more often a pacemaker (2.6%, 6.6%, 13.5%, p = 0.048). CONCLUSION: In clinical practice, the EFS is a useful tool to screen for frailty in TAVI patients. This tool may possibly be expanded to determine benefit versus harm-risk in these patients and whether specific pre-procedurally interventions are needed in order to reduce mortality.


Asunto(s)
Estenosis de la Válvula Aórtica , Fragilidad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Fragilidad/diagnóstico , Tiempo de Internación , Anciano Frágil , Medición de Riesgo , Factores de Riesgo , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Válvula Aórtica/cirugía , Resultado del Tratamiento
20.
Can J Cardiol ; 40(2): 300-312, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38072363

RESUMEN

With the expansion of transcatheter aortic valve replacement (TAVR) to younger and lower-surgical-risk patients, many younger and less comorbid patients will be treated with TAVR and are expected to have a life expectancy that will exceed the durability of their transcatheter heart valve. Consequently, the number of patients requiring reintervention will undoubtedly increase in the near future. Redo-TAVR and TAVR explantation followed by surgical aortic valve replacement are the different therapeutic options in the event of bioprosthetic valve failure and the need for reintervention. Patients often anticipate being able to benefit from a redo-TAVR in the event of bioprosthetic valve failure after TAVR, despite the lack of long-term data and the risk of unfavourable anatomy. Our understanding of the feasibility of redo-TAVR is constantly improving thanks to bench test studies and growing worldwide experience. However, much remains unknown. In clinical practice, one of the heart team's objectives is to anticipate the need to reaccess the coronary arteries and implant a second or even a third valve when life expectancy may exceed the durability of the transcatheter heart valve. In this review, we address key definitions in the diagnosis of structural valve deterioration and bioprosthetic valve failure, as well as patient selection and procedural planning for redo-TAVR to reduce periprocedural risk, optimise hemodynamic performance, and maintain coronary access. We describe the bench testing and literature in the redo-TAVR and TAVR explantation fields.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Factores de Riesgo , Bioprótesis/efectos adversos , Diseño de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...