Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.361
Filtrar
1.
J Nepal Health Res Counc ; 21(4): 593-598, 2024 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-38616588

RESUMEN

BACKGROUND: Rheumatic heart disease is a major cause of cardiovascular morbidity and mortality in developing nations and is a leading cause of hospital admission due to cardiac problems in our country. This study will evaluate the association between left atrial size and the occurrence of atrial fibrillation and describe the clinical characteristics along with complications related to Rheumatic Mitral valve disease. METHODS: A retrospective cross-sectional study was conducted at a tertiary care center from January 2018 to December 2019. Reports of 207 patients admitted to medical and/or surgical wards with echocardiographic diagnosis of rheumatic mitral valve disease with or without atrial fibrillation were reviewed. Data were collected, entered, and analyzed using the Statistical Package for the Social Science version 25.0. RESULTS: Among 207 patients, atrial fibrillation was present in 90 (43.5%) patients. Atrial fibrillation was higher in patients with mixed mitral valvular lesions compared to isolated mitral stenosis or mitral regurgitation. Univariate and multivariate analysis revealed left atrial size [aOR=1.067, 95% CI: 1.023 - 1.113, P= 0.002] and age [aOR = 1.073, 95% CI: 1.042 - 1.105, P<0.001] as an independent predictor of atrial fibrillation. CONCLUSIONS: Larger left atrium was an independent predictor of atrial fibrillation. Besides this, atrial fibrillation was associated with increasing age, mixed mitral valvular lesion, and moderately reduced left ventricular ejection fraction, but not associated with gender and mitral stenosis severity. Left atrial clot was significantly higher in patients with atrial fibrillation than in sinus rhythm.


Asunto(s)
Fibrilación Atrial , Estenosis de la Válvula Mitral , Cardiopatía Reumática , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico por imagen , Cardiopatía Reumática/complicaciones , Cardiopatía Reumática/diagnóstico por imagen , Válvula Mitral/diagnóstico por imagen , Estudios Transversales , Estenosis de la Válvula Mitral/complicaciones , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estudios Retrospectivos , Volumen Sistólico , Función Ventricular Izquierda , Nepal , Ecocardiografía
2.
Inn Med (Heidelb) ; 65(5): 439-446, 2024 May.
Artículo en Alemán | MEDLINE | ID: mdl-38597993

RESUMEN

There is a broad spectrum of mitral valve diseases ranging from young patients with rheumatic mitral valve stenosis up to older patients with secondary mitral valve regurgitation and numerous comorbidities. A profound understanding of the etiology, anatomical characteristics of mitral valve diseases and current treatment options is necessary to be able to prepare a patient-centered treatment approach. The interdisciplinary collaboration of referring physicians, interventional cardiologists, cardiac surgeons, heart failure and imaging specialists as well as anesthesiologists is a cornerstone of optimal patient treatment.


Asunto(s)
Cateterismo Cardíaco , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Cateterismo Cardíaco/métodos , Válvula Mitral/cirugía , Válvula Mitral/patología , Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Implantación de Prótesis de Válvulas Cardíacas/métodos
3.
BMJ Case Rep ; 17(4)2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38684360

RESUMEN

A patient in his 60s with a bioprosthetic aortic and mitral valve replacement presented with dyspnoea, tiredness and dizziness 2 years postoperatively. Transthoracic echocardiography showed mitral valve stenosis and increased pulmonary artery pressure suggesting bioprosthetic valve failure. Cardiac CT confirmed the diagnosis of bioprosthetic mitral valve thrombosis. Treatment with anticoagulation resulted in a remarkable improvement of the valve area and gradient and complete resolution of the thrombus. Herein, we report a case of rare bioprosthetic mitral valve thrombosis.


Asunto(s)
Bioprótesis , Prótesis Valvulares Cardíacas , Válvula Mitral , Trombosis , Tomografía Computarizada por Rayos X , Humanos , Masculino , Bioprótesis/efectos adversos , Trombosis/diagnóstico por imagen , Trombosis/etiología , Trombosis/tratamiento farmacológico , Prótesis Valvulares Cardíacas/efectos adversos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/diagnóstico por imagen , Anticoagulantes/uso terapéutico , Ecocardiografía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Persona de Mediana Edad , Falla de Prótesis
4.
Interv Cardiol Clin ; 13(2): 141-153, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38432758

RESUMEN

Echocardiographic imaging is the foundation for the evaluation of mitral valve dysfunction. Both transthoracic and transesophageal echocardiography provide insight into the anatomy, pathology, and classification mitral valve dysfunction. Echocardiography also provides a multi-parametric approach with semi-quantitative and quantitative parameters to assess the severity of mitral regurgitation and mitral stenosis. Transesophageal imaging is essential in the assessment of patients considered for surgical or transcatheter interventional strategies to treat mitral valve dysfunction. Cardiac computed tomography (CT) and cardiac MRI are useful adjunctive imaging techniques in mitral valve disease with CT providing detailed procedural specificity and MRI providing detailed ventricular and regurgitant flow analysis.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Estenosis de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Ecocardiografía
5.
J Pak Med Assoc ; 74(2): 243-246, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38419220

RESUMEN

Objectives: To evaluate accuracy of mitral leaflet separation index for the determination of mitral stenosis severity in patients with rheumatic mitral stenosis. METHODS: The prospective, cross-sectional study was conducted at the National Institute of Cardiovascular Diseases, Karachi, from March 2021 to February 2022, and comprised patients with rheumatic mitral stenosis detected on echocardiography. The best end-diastole parasternal long axis and apical four-chamber views were acquired and Mitral leaflet separation was measured as the distance between the inner edges of the tip of mitral leaflets. Pearson correlation coefficient was computed for mitral leaflet separation index and mitral valve area. Receiver operating characteristic curve was used to determine the cut-off value of the mitral leaflet separation indexto categorise mitral stenosis. Data was analysed using SPSS 19. RESULTS: Of the 277 patients, 205(74%) were females and 72(26%) were males. The overall mean age was 39.93±11.22 years. The mean mitral leaflet separation index value was 7.65±2.23. The correlation was significant and strong between mitral leaflet separation index and mitral valve area on planimetry (p<0.001), and was significant and moderate when measured by pressure half-time (p< 0.001). Mitral leaflet separation index cut-off value <8.625mm and <8.25mmcould predict severe mitral stenosis with 84% and 86.3% sensitivity and 84.6% and 78.3% specificity on planimetry and pressure half-time, respectively. CONCLUSIONS: The mitral leaflet separation index was found to be an independent, reliable and simple measure for assessing mitral stenosis severity.


Asunto(s)
Estenosis de la Válvula Mitral , Masculino , Femenino , Humanos , Adulto , Persona de Mediana Edad , Estenosis de la Válvula Mitral/diagnóstico por imagen , Válvula Mitral/diagnóstico por imagen , Estudios Prospectivos , Estudios Transversales , Índice de Severidad de la Enfermedad , Ecocardiografía
6.
West Afr J Med ; 41(1): 87-91, 2024 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-38412515

RESUMEN

It is not uncommon for congenital heart defects to occur in clusters. Those involving a right to left heart shunt commonly cause cyanosis and finger clubbing. Differential clubbing involving only the lower limb digits is a strong pointer to the presence of patent ductus arteriosus with reversal of shunt. We report a case of 25-year-old man with effort intolerance and differential clubbing. He was found to have the uncommon triad of patent ductus arteriosus, ventricular septal defect and supravalvular ring mitral stenosis. The presence of differential clubbing on a background of patent ductus arteriosus usually indicates a reversal of shunt and negates surgical intervention. This general rule may however not apply with co-existing mitral stenosis as the elevated pulmonary pressure may be predominantly post-capillary. The finding of mitral stenosis in a patient with patent ductus arteriosus and differential limb clubbing may signify a good prognostic surgical outcome.


Il n'est pas rare que des malformations cardiaques congénitales surviennent en clusters. Celles impliquant un shunt cardiaque droitegauche provoquent souvent une cyanose et un hippocratisme digital. L'hippocratisme digital différentiel touchant uniquement les orteils des membres inférieurs est un indicateur fort de la présence d'un canal artériel persistant avec inversion du shunt. Nous rapportons le cas d'un homme de 25 ans présentant une intolérance à l'effort et un hippocratisme digital différentiel. Il a été diagnostiqué avec la triade peu commune de canal artériel persistant, de communication interventriculaire et de sténose mitrale à anneau supravalvulaire. La présence d'un hippocratisme digital différentiel sur un fond de canal artériel persistant indique généralement une inversion du shunt et exclut une intervention chirurgicale. Cependant, cette règle générale peut ne pas s'appliquer en présence d'une sténose mitrale concomitante, car la pression pulmonaire élevée peut être principalement post-capillaire. La découverte d'une sténose mitrale chez un patient atteint de canal artériel persistant et d'un hippocratisme digital différentiel peut indiquer un bon pronostic pour l'intervention chirurgicale.


Asunto(s)
Conducto Arterioso Permeable , Defectos del Tabique Interventricular , Estenosis de la Válvula Mitral , Masculino , Humanos , Adulto , Conducto Arterioso Permeable/complicaciones , Conducto Arterioso Permeable/diagnóstico por imagen , Conducto Arterioso Permeable/cirugía , Estenosis de la Válvula Mitral/complicaciones , Estenosis de la Válvula Mitral/diagnóstico por imagen , Defectos del Tabique Interventricular/complicaciones , Defectos del Tabique Interventricular/diagnóstico por imagen , Defectos del Tabique Interventricular/cirugía
7.
Ann Cardiol Angeiol (Paris) ; 73(2): 101719, 2024 Apr.
Artículo en Francés | MEDLINE | ID: mdl-38266406

RESUMEN

Atrial myxoma is a rare and benign clinical entity. It remains common in women and mainly affects the left atrium. Its clinical picture is polymorphic. We report the case of a 53-year-old woman who consulted for dyspnea with cardiac failure's picture. The diagnosis of myxoma of the left atrium was made on echocardiography which also objectified the existence of mitral stenosis. The patient underwent surgical excision and mitral valve replacement with good postoperative outcomes.


Asunto(s)
Neoplasias Cardíacas , Estenosis de la Válvula Mitral , Mixoma , Humanos , Femenino , Persona de Mediana Edad , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/etiología , Estenosis de la Válvula Mitral/cirugía , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Ecocardiografía , Neoplasias Cardíacas/complicaciones , Neoplasias Cardíacas/diagnóstico por imagen , Neoplasias Cardíacas/cirugía , Mixoma/diagnóstico , Mixoma/diagnóstico por imagen
8.
Catheter Cardiovasc Interv ; 103(1): 238-242, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37971094

RESUMEN

A 75-year-old female was found to have mechanical mitral valve thrombosis complicated by severe mitral stenosis, pulmonary edema, and right heart failure. She was at prohibitive risk for surgical intervention. She did not tolerate thrombolysis due to bleeding. We performed percutaneous intervention with cerebral protection with subsequent restoration of mechanical mitral valve function, resolution of the mitral valve stenosis, and no neurologic complications.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Estenosis de la Válvula Mitral , Trombosis , Femenino , Humanos , Anciano , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Trombosis/diagnóstico por imagen , Trombosis/etiología , Trombosis/terapia , Prótesis Valvulares Cardíacas/efectos adversos
12.
Int J Cardiovasc Imaging ; 40(3): 535-543, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38104039

RESUMEN

An increase in the volume and pressure of the heart chambers has been shown to increase liver stiffness. The Albumin-Bilirubin (ALBI) score is useful and easy-to-use for objectively assessing liver function. There is no information in the literature regarding changes in ALBI scores in patients with rheumatic mitral stenosis (MS). The aim of our study was to investigate changes in ALBI score and its clinical impact in patients with MS. Of the 247 patients analyzed, 54 were excluded from the study. The remaining 193 patients with MS were divided into two groups: Group I (64 patients with mitral valve area > 1.5 cm2 and mean transmitral gradient < 10 mmHg) and Group II (129 patients with mitral valve area ≤ 1.5 cm2 and mean transmitral gradient ≥ 10 mmHg). The ALBI score was calculated based on serum albumin and total bilirubin levels using the following formula: ALBI= (log10 bilirubin [µmol/L] × 0.66) + (albumin [g/L] × - 0.085). A significant correlation was found between the ALBI score and mitral valve area in patients with MS (r = - 0.479, p < 0.001*) (Table 4; Fig. 3A). An ALBI score greater than - 2.61 was associated with severe MS (mitral valve area < 1.5 cm2), with a sensitivity of 72% and a specificity of 69% (Area under the ROC curve = 0.726; p < 0.001; 95% CI 0.650-0.802) (Fig. 4A). A significant correlation was found between the ALBI score and mean transmitral gradient in patients with MS (r = 0.476; p < 0.001*) (Table 4; Fig. 3B). An ALBI score greater than - 2.57 was associated with severe MS (mean transmitral gradient < 10 mmHg), with a sensitivity of 65% and a specificity of 67% (Area under the ROC curve = 0.684; p < 0.001; 95% CI 0.608-0.759) (Fig. 4B). In multivariate linear regression analysis, mitral valve area and mean transmitral gradient were significantly associated with increased ALBI scores (p < 0.05). Mitral valve area, mean transmitral gradient, and NT-proBNP levels were significantly associated with the ALBI score. The ALBI score could provide an information about the severity of MS. The ALBI score is a simple, evidence-based, objective, and discriminatory method for assessing liver function in patients with MS.Please check and confirm that the authors and their respective affiliations have been correctly identified and amend if necessary.Authors and their respective affiliations are correctly identified.


Asunto(s)
Estenosis de la Válvula Mitral , Humanos , Estenosis de la Válvula Mitral/diagnóstico por imagen , Válvula Mitral/diagnóstico por imagen , Bilirrubina , Valor Predictivo de las Pruebas , Ecocardiografía/métodos , Albúminas
13.
BMC Cardiovasc Disord ; 23(1): 616, 2023 12 14.
Artículo en Inglés | MEDLINE | ID: mdl-38097932

RESUMEN

BACKGROUND: Mitral valve stenosis can be a highly symptomatic condition with significant complications if left untreated. In such cases, mitral valve replacement with a bioprosthetic or mechanical valve may be a viable solution to prevent progressive disease. Current guidelines do not recommend continued anticoagulation beyond 6 months for patients who have undergone bioprosthetic valve replacement without a separate indication for anticoagulation. With this case discussion we aim to 1) Review the current indications for anticoagulation for bioprosthetic mitral valves in patients without atrial fibrillation and 2) Discuss the constellation of comorbidities that may affect the decision to begin anticoagulation therapy. CASE PRESENTATION: We present a case describing a 55-year-old male with end-stage renal disease, coronary artery disease with coronary artery bypass graft surgery, and bioprosthetic mitral valve replacement 2 years prior with rapid degeneration of the replaced valve and on warfarin without a clear indication for anticoagulation. The patient was admitted for symptomatic, severe mitral stenosis and consideration of transcatheter mitral valve-in-valve replacement. During hospital admission, warfarin was discontinued and replaced with prophylactic anticoagulation. However, 8 days after warfarin cessation an intraoperative transesophageal echocardiography revealed a newly developed large left atrial thrombus leading to cancellation of the planned operation. CONCLUSIONS: This patient developed a left atrial thrombus after discontinuing warfarin in the setting of rapidly deteriorating bioprosthetic valve stenosis and vascular comorbidities. The decision to discontinue warfarin was made in concordance with current guidelines, which do not indicate systemic anticoagulation post 3-6 months after bioprosthetic valve replacement without separate indication for anticoagulation. This case identifies the need to investigate rebound hypercoagulability and further risk stratify comorbidities which may independently increase the risk of clot formation in the setting of severe mitral valve stenosis.


Asunto(s)
Bioprótesis , Prótesis Valvulares Cardíacas , Estenosis de la Válvula Mitral , Trombosis , Humanos , Masculino , Persona de Mediana Edad , Anticoagulantes/efectos adversos , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/cirugía , Trombosis/diagnóstico por imagen , Trombosis/etiología , Trombosis/prevención & control , Warfarina/efectos adversos
14.
BMJ Case Rep ; 16(12)2023 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-38114299

RESUMEN

Double orifice mitral valve (DOMV) is an extremely rare congenital anomaly of the mitral valve (MV) wherein the MV orifice divides into two separate orifices by an accessory fibrous band.Isolated DOMV is a rarity and is often discovered incidentally. It may be associated with other congenital conditions wherein it is identified in early childhood. Its prevalence and prognostic relevance in adulthood remain unclear. DOMV patients may be asymptomatic or have symptoms due to mitral stenosis or regurgitation. We present a case of an asymptomatic young adult initially diagnosed with rheumatic mitral stenosis. However, after a thorough echocardiographic assessment, including three-dimensional transesophageal echocardiography, the accurate diagnosis of DOMV was made.


Asunto(s)
Cardiopatías Congénitas , Enfermedades de las Válvulas Cardíacas , Estenosis de la Válvula Mitral , Cardiopatía Reumática , Humanos , Adulto Joven , Errores Diagnósticos , Ecocardiografía Transesofágica , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/complicaciones , Enfermedades de las Válvulas Cardíacas/complicaciones , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/anomalías , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/complicaciones , Cardiopatía Reumática/diagnóstico por imagen , Cardiopatía Reumática/complicaciones
15.
BMC Cardiovasc Disord ; 23(1): 584, 2023 11 27.
Artículo en Inglés | MEDLINE | ID: mdl-38012599

RESUMEN

BACKGROUND: The present study aimed to detect subtle left ventricular (LV) dysfunction in patients with severe rheumatic mitral stenosis (MS) by measuring global and segmental longitudinal strain with a two-dimensional speckle tracking echocardiography (2D-STE) method. METHODS: In this case-control study, 65 patients with severe rheumatic MS and preserved ejection fraction (EF ≥ 50% measured by conventional echocardiographic methods) were compared with 31 otherwise healthy control subjects. All patients underwent LV strain measurement by the 2D-STE method in addition to conventional echocardiography using a VIVID S60 echocardiography device. RESULTS: Absolute strain values in myocardial segments 1-8, 10, and 12 (all basal, mid anterior, mid anteroseptal, mid inferior, and mid anterolateral segments) were significantly lower in patients with severe MS compared with the control group (P < 0.05 for all). The absolute global longitudinal strain (GLS) value was higher in the control group (-19.56 vs. -18.25; P = 0.006). After adjustment for age, gender, and systolic blood pressure, the difference in GLS between the two groups was as follows: mean difference=-1.16; 95% CI: -2.58-0.25; P = 0.110. CONCLUSION: In patients with severe rheumatic MS and preserved EF, the absolute GLS tended to be lower than healthy controls. Furthermore, the segmental strain values of LV were significantly lower in most of the basal and some mid-myocardial segments. Further studies are warranted to investigate the underlying pathophysiology and clinical implications of this subclinical dysfunction in certain segments of patients with severe rheumatic MS.


Asunto(s)
Estenosis de la Válvula Mitral , Disfunción Ventricular Izquierda , Humanos , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/etiología , Estudios de Casos y Controles , Tensión Longitudinal Global , Ecocardiografía/métodos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/etiología , Función Ventricular Izquierda/fisiología
17.
Int J Cardiovasc Imaging ; 39(11): 2183-2192, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37798420

RESUMEN

PURPOSES: Predicting hemodynamic changes of stenotic mitral valve (MV) lesions with mitral annular calcification (MAC) following transcatheter aortic valve implantation (TAVI) may inform clinical decision-making. This study aimed to investigate the association between the MAC severity quantified by computed tomography (CT) and changes in mean transmitral gradient (mTMG), mitral valve area (MVA) and stroke volume index (SVi) following TAVI. METHODS AND RESULTS: A total of 708 patients (median age 81, 52% male) with severe aortic stenosis (AS) underwent pre-procedural CT and pre- and post-TAVI transthoracic echocardiography. According to the classification of MAC severity determined by CT, 299 (42.2%) patients had no MAC, 229 (32.3%) mild MAC, 102 (14.4%) moderate MAC, and 78 (11.0%) severe MAC. After adjusting for age and sex, there was no significant change in mTMG following TAVI (Δ mTMG = 0.07 mmHg, 95% CI -0.10 to 0.23, P = 0.92) for patients with no MAC. In contrast, patients with mild MAC (Δ mTMG = 0.21 mmHg, 95% CI 0.01 to 0.40, P = 0.018), moderate MAC (Δ mTMG = 0.31 mmHg, 95% CI 0.02 to 0.60, P = 0.019) and severe MAC (Δ mTMG = 0.43 mmHg, 95% CI 0.10 to 0.76, P = 0.0012) had significant increases in mTMG following TAVI, with greater changes associated with increasing MAC severity. In contrast, there was no significant change in MVA or SVi following TAVI. CONCLUSION: In patients with severe AS undergoing TAVI, MAC severity was associated with greater increases in post-procedural mTMG whereas MVA or SVi remained unchanged. MAC severity should be considered for potential subsequent MV interventions if TAVI does not improve symptoms.


Asunto(s)
Estenosis de la Válvula Aórtica , Calcinosis , Estenosis de la Válvula Mitral , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Anciano de 80 o más Años , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Resultado del Tratamiento , Valor Predictivo de las Pruebas , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/complicaciones , Calcinosis/diagnóstico por imagen , Calcinosis/cirugía , Calcinosis/complicaciones , Hemodinámica , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/patología , Índice de Severidad de la Enfermedad
19.
Int J Cardiovasc Imaging ; 39(12): 2419-2426, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37658988

RESUMEN

PURPOSE: To assess reproducibility of Real time 3D echocardiography (RT3D) and ECG-gated 3D echocardiography (EG3D) when measuring the mitral valve area (MVA) in rheumatic mitral stenosis (MS). METHODS: MVA was assessed by three operators in 68 MS patients using RT3D and EG3D. Reproducibility of each technique was determined by calculating the standard error of measurements (SEM). RESULTS: SEM was similar between RT3D and EG3D. MVA variability was of 0.4 cm² or 30% of any RT3D or EG3D measured MVA. The minimal change in MVA above which two measurements should be considered to differ significantly for the same operator was of 0.4 cm² for RT3D and 0.5 cm² for EG3D. For two different operators making successive measurements, the minimum significant change was of 0.5 cm² for RT3D and 0.6 cm² for EG3D. The minimum significant difference when switching from RT3D to EG3D or vice versa is of 0.6 cm². Low temporal resolution of 6 Hz has the least variability when using RT3D (0.19 cm² vs. 0.26 cm², p = 0.009) but significantly underestimated MVA (1.3 ± 0.4 cm² vs. 1.4 ± 0.4 cm², p < 10- 3) when compared to EG3D. MVA variability was significantly higher in mild MS when compared to severe MS whether it is RT3D (0.23 cm² vs. 0.18 cm², p = 0.02) or EG3D (0.27 cm² vs. 0.16 cm², p < 0.001). CONCLUSION: RT3D and EG3D are equally reproducible in the assessment of MVA in patients with MS. Further measurements standardization is required to have a clinically acceptable estimations of the true 3D MVA and minimal detectable differences.


Asunto(s)
Ecocardiografía Tridimensional , Estenosis de la Válvula Mitral , Humanos , Estenosis de la Válvula Mitral/diagnóstico por imagen , Válvula Mitral/diagnóstico por imagen , Reproducibilidad de los Resultados , Valor Predictivo de las Pruebas , Ecocardiografía Tridimensional/métodos , Electrocardiografía
20.
Methodist Debakey Cardiovasc J ; 19(1): 61-63, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37636318

RESUMEN

A 56-year-old man with no significant past medical history presented with exertional shortness of breath. Echocardiogram, cardiac magnetic resonance, and computed tomography showed mitral stenosis and a left atrial thrombus. Left atrial thrombus formation is a well-known complication of severe mitral stenosis that can lead to systemic thromboembolism. The patient underwent mitral valve replacement, left atrial thrombus resection, and left atrial appendage closure that resulted in significant improvement in breathing.


Asunto(s)
Fibrilación Atrial , Estenosis de la Válvula Mitral , Tromboembolia , Trombosis , Masculino , Humanos , Persona de Mediana Edad , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/cirugía , Corazón , Trombosis/diagnóstico por imagen , Trombosis/etiología , Trombosis/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...