Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
BMC Vet Res ; 15(1): 49, 2019 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-30717756

RESUMEN

BACKGROUND: Prostatic diseases are common and mostly associated with enlargement of the accessory gland. Thus, determining the prostate size has become a main criterion for evaluating prostate health status. Computed tomography (CT) is recommended as a beneficial tool for evaluating prostate size, morphology and surrounding tissues. The purpose of this study was to establish an accurate procedure for volume estimation and afterwards evaluate the prostate volume in CT. Data of 95 dogs were analysed (58 male intact, 37 male neutered) using the slice addition technique with the Amira program. Accuracy of volumetric measurements by CT was validated by comparing them with those of phantoms of known volume. Patients were grouped according to age (< 4 yrs., 4-8 yrs., > 8 yrs) and prostate morphology in CT (H = homogeneous, I = inhomogeneous, C = cystic). The length of the sixth lumbar vertebra was measured to relate prostate volume to body size. This ratio was generated to compare prostate volume between the groups, irrespective of body size (ratio volume = Rv). RESULTS: A high correlation between the CT-derived and phantom volume was found. Overall, the mean prostate volume was 58.6 cm3. The mean ratio volume was 1.3 in intact male dogs, this being significantly higher than in neutered dogs (0.7). The lowest ratio volume values were found in group H for intact (Rv = 0.9) and neutered dogs (Rv = 0.6), followed by group I (intact: Rv = 1.1; neutered: Rv = 0.7) and C (intact: Rv = 1.4; neutered: Rv = 0.8). The length of the sixth lumbar vertebra was well correlated with the prostate volume (intact: r = 0.63, p < 0.001; neutered: r = 0.48, p = 0.003), while age exhibited a correlation only in intact dogs (r = 0.52, p < 0.001). CONCLUSION: The present study is pioneering in applying a slice addition technique to volumetric measurements of the prostate gland in CT, resulting in a highly precise method. Volumetric measurements of the canine prostate gland in CT images provide information about the prostate structure, castration status, age and body size of the patients. Therefore, prostate volume is a relevant parameter for evaluating prostate health status.


Asunto(s)
Perros/anatomía & histología , Próstata/diagnóstico por imagen , Animales , Vértebras Lumbares/anatomía & histología , Vértebras Lumbares/diagnóstico por imagen , Masculino , Tamaño de los Órganos , Fantasmas de Imagen/veterinaria , Próstata/anatomía & histología , Reproducibilidad de los Resultados , Estudios Retrospectivos , Programas Informáticos , Tomografía Computarizada por Rayos X/veterinaria
2.
Vet Radiol Ultrasound ; 59(4): 432-443, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29424062

RESUMEN

Postcontrast, fluid-attenuated inversion recovery (FLAIR) sequences are reported to be of variable value in veterinary and human neuroimaging. The source of hyperintensity in postcontrast-T2 FLAIR images is inconsistently reported and has implications for the significance of imaging findings. We hypothesized that the main source of increased signal intensity in postcontrast-T2 FLAIR images would be due to gadolinium leakage into adjacent fluid, and that the resulting gadolinium-induced T1 shortening causes reappearance of fluid hyperintensity, previously nulled on precontrast FLAIR images. A retrospective, descriptive study was carried out comparing T2 weighted, pre- and postcontrast T1 weighted and pre- and postcontrast weighted T2 FLAIR images in a variety of intracranial diseases in dogs and cats. A prospective, experimental, phantom, in vitro study was also done to compare the relative effects of gadolinium concentration on T2 weighted, T1 weighted, and FLAIR images. A majority of hyperintensities on postcontrast-T2 FLAIR images that were not present on precontrast FLAIR images were also present on precontrast T2 weighted images, and were consistent with normal or pathological fluid filled structures. Phantom imaging demonstrated increased sensitivity of FLAIR sequences to low concentrations of gadolinium compared to T1 weighted sequences. Apparent contrast enhancement on postcontrast-T2 FLAIR images often reflects leakage of gadolinium across normal or pathology specific barriers into fluid-filled structures, and hyperintensity may therefore represent normal fluid structures as well as pathological tissues. Findings indicated that postcontrast-T2 FLAIR images may provide insight into integrity of biological structures such as the ependymal and subarachnoid barriers that may be relevant to progression of disease.


Asunto(s)
Enfermedades de los Gatos/diagnóstico por imagen , Enfermedades de los Perros/diagnóstico por imagen , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/veterinaria , Neuroimagen/instrumentación , Neuroimagen/veterinaria , Fantasmas de Imagen/veterinaria , Animales , Gatos , Líquido Cefalorraquídeo/diagnóstico por imagen , Perros , Gadolinio/química , Estudios Prospectivos , Estudios Retrospectivos
3.
Radiat Res ; 187(4): 433-442, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28140787

RESUMEN

Anatomically accurate phantoms are useful tools for radiation dosimetry studies. In this work, we demonstrate the construction of a new generation of life-like mouse phantoms in which the methods have been generalized to be applicable to the fabrication of any small animal. The mouse phantoms, with built-in density inhomogeneity, exhibit different scattering behavior dependent on where the radiation is delivered. Computer models of the mouse phantoms and a small animal irradiation platform were devised in Monte Carlo N-Particle code (MCNP). A baseline test replicating the irradiation system in a computational model shows minimal differences from experimental results from 50 Gy down to 0.1 Gy. We observe excellent agreement between scattered dose measurements and simulation results from X-ray irradiations focused at either the lung or the abdomen within our phantoms. This study demonstrates the utility of our mouse phantoms as measurement tools with the goal of using our phantoms to verify complex computational models.


Asunto(s)
Materiales Biomiméticos/efectos de la radiación , Fantasmas de Imagen/veterinaria , Radiometría/instrumentación , Radiometría/veterinaria , Dispersión de Radiación , Irradiación Corporal Total/veterinaria , Animales , Simulación por Computador , Diseño de Equipo , Análisis de Falla de Equipo , Ratones , Modelos Biológicos , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/veterinaria , Irradiación Corporal Total/instrumentación
4.
PLoS One ; 11(4): e0154193, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27101001

RESUMEN

Digital radiographic imaging is increasing in veterinary practice. The use of radiation demands responsibility to maintain high image quality. Low doses are necessary because workers are requested to restrain the animal. Optimizing digital systems is necessary to avoid unnecessary exposure, causing the phenomenon known as dose creep. Homogeneous phantoms are widely used to optimize image quality and dose. We developed an automatic computational methodology to classify and quantify tissues (i.e., lung tissue, adipose tissue, muscle tissue, and bone) in canine chest computed tomography exams. The thickness of each tissue was converted to simulator materials (i.e., Lucite, aluminum, and air). Dogs were separated into groups of 20 animals each according to weight. Mean weights were 6.5 ± 2.0 kg, 15.0 ± 5.0 kg, 32.0 ± 5.5 kg, and 50.0 ± 12.0 kg, for the small, medium, large, and giant groups, respectively. The one-way analysis of variance revealed significant differences in all simulator material thicknesses (p < 0.05) quantified between groups. As a result, four phantoms were constructed for dorsoventral and lateral views. In conclusion, the present methodology allows the development of phantoms of the canine chest and possibly other body regions and/or animals. The proposed phantom is a practical tool that may be employed in future work to optimize veterinary X-ray procedures.


Asunto(s)
Fantasmas de Imagen/veterinaria , Dosis de Radiación , Radiografía Torácica/veterinaria , Tomografía Computarizada por Rayos X/veterinaria , Animales , Perros , Radiografía Torácica/métodos , Reproducibilidad de los Resultados , Tórax , Tomografía Computarizada por Rayos X/métodos , Medicina Veterinaria/métodos , Rayos X
5.
J Environ Radioact ; 151 Pt 2: 480-6, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25971772

RESUMEN

Radiation dose to biota is generally calculated using Monte Carlo simulations of whole body ellipsoids with homogeneously distributed radioactivity throughout. More complex anatomical phantoms, termed voxel phantoms, have been developed to test the validity of these simplistic geometric models. In most voxel models created to date, human tissue composition and density values have been used in lieu of biologically accurate values for non-human biota. This has raised questions regarding variable tissue composition and density effects on the fraction of radioactive emission energy absorbed within tissues (e.g. the absorbed fraction - AF), along with implications for age-dependent dose rates as organisms mature. The results of this study on rabbits indicates that the variation in composition between two mammalian tissue types (e.g. human vs rabbit bones) made little difference in self-AF (SAF) values (within 5% over most energy ranges). However, variable tissue density (e.g. bone vs liver) can significantly impact SAF values. An examination of differences across life-stages revealed increasing SAF with testis and ovary size of over an order of magnitude for photons and several factors for electrons, indicating the potential for increasing dose rates to these sensitive organs as animals mature. AFs for electron energies of 0.1, 0.2, 0.4, 0.5, 0.7, 1.0, 1.5, 2.0, and 4.0 MeV and photon energies of 0.01, 0.015, 0.02, 0.03, 0.05, 0.1, 0.2, 0.5, 1.0, 1.5, 2.0, and 4.0 MeV are provided for eleven rabbit tissues. The data presented in this study can be used to calculate accurate organ dose rates for rabbits and other small rodents; to aide in extending dose results among different mammal species; and to validate the use of ellipsoidal models for regulatory purposes.


Asunto(s)
Liebres/metabolismo , Modelos Biológicos , Fantasmas de Imagen/veterinaria , Dosis de Radiación , Monitoreo de Radiación/instrumentación , Monitoreo de Radiación/métodos , Animales , Carga Corporal (Radioterapia) , Simulación por Computador , Electrones , Femenino , Masculino , Método de Montecarlo , Fotones , Distribución Tisular
6.
Ultrasound Med Biol ; 41(8): 2232-9, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25957754

RESUMEN

Velocity measurement errors were investigated for an array-based preclinical ultrasound scanner (Vevo 2100, FUJIFILM VisualSonics, Toronto, ON, Canada). Using a small-size rotating phantom made from a tissue-mimicking material, errors in pulse-wave Doppler maximum velocity measurements were observed. The extent of these errors was dependent on the Doppler angle, gate length, gate depth, gate horizontal placement and phantom velocity. Errors were observed to be up to 172% at high beam-target angles. It was found that small gate lengths resulted in larger velocity errors than large gate lengths, a phenomenon that has not previously been reported (e.g., for a beam-target angle of 0°, the error was 27.8% with a 0.2-mm gate length and 5.4% with a 0.98-mm gate length). The error in the velocity measurement with sample volume depth changed depending on the operating frequency of the probe. Some edge effects were observed in the horizontal placement of the sample volume, indicating a change in the array aperture size. The error in the velocity measurements increased with increased phantom velocity, from 22% at 2.4 cm/s to 30% at 26.6 cm/s. To minimise the impact of these errors, an angle-dependent correction factor was derived based on a simple ray model of geometric spectral broadening. Use of this angle-dependent correction factor reduces the maximum velocity measurement errors to <25% in all instances, significantly improving the current estimation of maximum velocity from pulse-wave Doppler ultrasound.


Asunto(s)
Arterias/diagnóstico por imagen , Arterias/fisiología , Velocidad del Flujo Sanguíneo/fisiología , Fantasmas de Imagen/veterinaria , Ultrasonografía Doppler/instrumentación , Ultrasonografía Doppler/veterinaria , Animales , Diseño de Equipo , Análisis de Falla de Equipo/instrumentación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
7.
J Magn Reson Imaging ; 42(6): 1759-64, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26012876

RESUMEN

PURPOSE: To evaluate between-site agreement of apparent diffusion coefficient (ADC) measurements in preclinical magnetic resonance imaging (MRI) systems. MATERIALS AND METHODS: A miniaturized thermally stable ice-water phantom was devised. ADC (mean and interquartile range) was measured over several days, on 4.7T, 7T, and 9.4T Bruker, Agilent, and Magnex small-animal MRI systems using a common protocol across seven sites. Day-to-day repeatability was expressed as percent variation of mean ADC between acquisitions. Cross-site reproducibility was expressed as 1.96 × standard deviation of percent deviation of ADC values. RESULTS: ADC measurements were equivalent across all seven sites with a cross-site ADC reproducibility of 6.3%. Mean day-to-day repeatability of ADC measurements was 2.3%, and no site was identified as presenting different measurements than others (analysis of variance [ANOVA] P = 0.02, post-hoc test n.s.). Between-slice ADC variability was negligible and similar between sites (P = 0.15). Mean within-region-of-interest ADC variability was 5.5%, with one site presenting a significantly greater variation than the others (P = 0.0013). CONCLUSION: Absolute ADC values in preclinical studies are comparable between sites and equipment, provided standardized protocols are employed.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/instrumentación , Imagen de Difusión por Resonancia Magnética/veterinaria , Aumento de la Imagen/instrumentación , Interpretación de Imagen Asistida por Computador/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Europa (Continente) , Fantasmas de Imagen/veterinaria , Fantasmas de Imagen/virología , Estados Unidos
8.
Am J Vet Res ; 75(7): 642-7, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24959730

RESUMEN

OBJECTIVE: To determine the effect of region of interest (ROI) setting and slice thickness on trabecular bone mineral density (BMD) measured with quantitative CT in dogs. ANIMALS: 14 healthy Beagles. PROCEDURES: CT of the lumbar vertebrae and a quantitative CT phantom was performed. The BMD of trabecular bone was measured from L1 to L7 in 2 ways in all dogs. First, sequential 9.6-mm-thick CT images were acquired and then CT images were reconstructed into transverse CT images with slice thicknesses of 2.4, 4.8, and 9.6 mm. The obtained images were analyzed by circular ROI and trace ROI methods. Second, lumbar vertebrae were scanned with the installed quantitative CT protocol with a slice thickness of 10 mm and then the CT images were analyzed by installed automatic BMD software. RESULTS: Interclass correlation coefficients of the automatic software (0.975 to 1.0) and the circular method (0.871 to 0.996) were high, compared with those of the trace method (0.582 to 0.996). The BMD measured with the automatic software was not significantly different from that measured with circular ROI and a slice thickness of 9.6 mm. The BMD measured by use of the circular method was not different according to slice thickness. CONCLUSIONS AND CLINICAL RELEVANCE: Results obtained by use of automatic software were similar to those obtained by use of more manual methods. The CT images with thinner slice thickness (2.4 and 4.8 mm) could be used in dogs of toy and small breeds to measure lumbar vertebrae BMD to reduce the limitations of the standard 10-mm slice thickness.


Asunto(s)
Densidad Ósea/fisiología , Perros/fisiología , Vértebras Lumbares/fisiología , Tomografía Computarizada por Rayos X/veterinaria , Animales , Femenino , Vértebras Lumbares/diagnóstico por imagen , Masculino , Fantasmas de Imagen/veterinaria , Programas Informáticos , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos
9.
Magn Reson Med ; 71(2): 880-4, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23440883

RESUMEN

PURPOSE: Magnetic resonance imaging (MRI) is widely used in human brain research to evaluate the effects of healthy aging and development, as well as neurological disorders. Although standardized methods for quality assurance of human MRI instruments have been established, such approaches have typically not been translated to small animal imaging. We present a method for the generation and analysis of customized phantoms for small animal MRI systems that allows rapid and accurate system stability monitoring. METHODS: Computer-aided design software was used to produce a customized phantom using a rapid prototyping printer. Automated registration algorithms were used on three-dimensional images of the phantom to allow system stability to be easily monitored over time. RESULTS: The design of the custom phantom allowed reliable placement relative to the imaging coil. Automated registration showed superior ability to detect gradient changes reflected in the images than with manual measurements. Registering images acquired over time allowed monitoring of gradient drifts of less than one percent. CONCLUSION: A low cost, MRI compatible phantom was successfully designed using computer-aided design software and a three-dimensional printer. Registering phantom images acquired over time allows monitoring of gradient stability of the MRI system.


Asunto(s)
Imagenología Tridimensional/instrumentación , Imagenología Tridimensional/veterinaria , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/veterinaria , Fantasmas de Imagen/veterinaria , Animales , Diseño de Equipo , Análisis de Falla de Equipo , Imagenología Tridimensional/normas , Imagen por Resonancia Magnética/normas , Fantasmas de Imagen/normas , Control de Calidad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
10.
Vet Radiol Ultrasound ; 54(6): 618-22, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23763334

RESUMEN

The ability to read patient identification microchips relies on the use of radiofrequency pulses. Since radiofrequency pulses also form an integral part of the magnetic resonance imaging (MRI) process, the possibility of loss of microchip function during MRI scanning is of concern. Previous clinical trials have shown microchip function to be unaffected by MR imaging using a field strength of 1 Tesla and 1.5. As veterinary MRI scanners range widely in field strength, this study was devised to determine whether exposure to lower or higher field strengths than 1 Tesla would affect the function of different types of microchip. In a phantom study, a total of 300 International Standards Organisation (ISO)-approved microchips (100 each of three different types: ISO FDX-B 1.4 × 9 mm, ISO FDX-B 2.12 × 12 mm, ISO HDX 3.8 × 23 mm) were tested in a low field (0.5) and a high field scanner (3.0 Tesla). A total of 50 microchips of each type were tested in each scanner. The phantom was composed of a fluid-filled freezer pack onto which a plastic pillow and a cardboard strip with affixed microchips were positioned. Following an MRI scan protocol simulating a head study, all of the microchips were accurately readable. Neither 0.5 nor 3 Tesla imaging affected microchip function in this study.


Asunto(s)
Sistemas de Identificación Animal/veterinaria , Sistemas de Identificación Animal/instrumentación , Animales , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/veterinaria , Fantasmas de Imagen/veterinaria
11.
Ultrasound Med Biol ; 39(8): 1491-9, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23711503

RESUMEN

Preclinical ultrasound scanners are used to measure blood flow in small animals, but the potential errors in blood velocity measurements have not been quantified. This investigation rectifies this omission through the design and use of phantoms and evaluation of measurement errors for a preclinical ultrasound system (Vevo 770, Visualsonics, Toronto, ON, Canada). A ray model of geometric spectral broadening was used to predict velocity errors. A small-scale rotating phantom, made from tissue-mimicking material, was developed. True and Doppler-measured maximum velocities of the moving targets were compared over a range of angles from 10° to 80°. Results indicate that the maximum velocity was overestimated by up to 158% by spectral Doppler. There was good agreement (<10%) between theoretical velocity errors and measured errors for beam-target angles of 50°-80°. However, for angles of 10°-40°, the agreement was not as good (>50%). The phantom is capable of validating the performance of blood velocity measurement in preclinical ultrasound.


Asunto(s)
Evaluación Preclínica de Medicamentos/instrumentación , Evaluación Preclínica de Medicamentos/veterinaria , Fantasmas de Imagen/veterinaria , Ultrasonografía Doppler/instrumentación , Ultrasonografía Doppler/veterinaria , Animales , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Ratones , Miniaturización , Ratas , Reproducibilidad de los Resultados , Rotación , Sensibilidad y Especificidad
12.
Vet Radiol Ultrasound ; 54(4): 332-342, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23551960

RESUMEN

The purpose of this study was to describe application and machine accuracy for a new computed tomography (CT) guided, frameless, stereotactic brain biopsy system in dogs. Heads from ten canine cadavers were secured to a bite-plate with six attached fiducial markers and imaged using CT. Fiducialized CT images were imported into stereotactic software and spherical phantom lesions between 3.9 and 5.5 mm in diameter were created in six locations. Infrared cameras and reflective markers were used to register fiducials to the reconstructed image set. Coordinates in the X, Y, and Z planes were identified for each lesion center. Iohexol (1.5 µl of 240 mgI/ml) was injected into the center of each lesion and CT scans were repeated. Pre- and postinjection CT images for each cadaver were fused using the system software. Application accuracy was calculated using the center of each phantom lesion and the center of each injected contrast material location. Machine accuracy was calculated using a phantom with known distances between four fixed points in the X, Y, and Z planes. Mean application accuracy in the first 5 cadavers was 4.3 mm (95% confidence interval [CI] 2.9-4.3 mm) and in the second 5 cadavers was 2.9 mm (95% CI 2-3.9 mm). The more superficial lesions were targeted significantly less accurately than the deeper lesions (P = 0.0183). Median machine accuracy was 0.1 mm and the range was 0.1-0.2 mm. Findings supported use of the new biopsy system for canine brain lesions >3.9 mm in diameter.


Asunto(s)
Biopsia/métodos , Encéfalo/patología , Perros/anatomía & histología , Tomografía Computarizada por Rayos X/métodos , Animales , Biopsia/instrumentación , Biopsia/veterinaria , Cadáver , Medios de Contraste/química , Imagenología Tridimensional/instrumentación , Imagenología Tridimensional/métodos , Imagenología Tridimensional/veterinaria , Yohexol/química , Fantasmas de Imagen/veterinaria , Sensibilidad y Especificidad , Técnicas Estereotáxicas/instrumentación , Técnicas Estereotáxicas/veterinaria , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/veterinaria
13.
Appl Radiat Isot ; 75: 105-14, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23501360

RESUMEN

In this work we developed a Monte Carlo (MC) model of the Sedecal Argus pre-clinical PET scanner, using GATE (Geant4 Application for Tomographic Emission). This is a dual-ring scanner which features DOI compensation by means of two layers of detector crystals (LYSO and GSO). Geometry of detectors and sources, pulses readout and selection of coincidence events were modeled with GATE, while a separate code was developed in order to emulate the processing of digitized data (for example, customized time windows and data flow saturation), the final binning of the lines of response and to reproduce the data output format of the scanner's acquisition software. Validation of the model was performed by modeling several phantoms used in experimental measurements, in order to compare the results of the simulations. Spatial resolution, sensitivity, scatter fraction, count rates and NECR were tested. Moreover, the NEMA NU-4 phantom was modeled in order to check for the image quality yielded by the model. Noise, contrast of cold and hot regions and recovery coefficient were calculated and compared using images of the NEMA phantom acquired with our scanner. The energy spectrum of coincidence events due to the small amount of (176)Lu in LYSO crystals, which was suitably included in our model, was also compared with experimental measurements. Spatial resolution, sensitivity and scatter fraction showed an agreement within 7%. Comparison of the count rates curves resulted satisfactory, being the values within the uncertainties, in the range of activities practically used in research scans. Analysis of the NEMA phantom images also showed a good agreement between simulated and acquired data, within 9% for all the tested parameters. This work shows that basic MC modeling of this kind of system is possible using GATE as a base platform; extension through suitably written customized code allows for an adequate level of accuracy in the results. Our careful validation against experimental data confirms that the developed simulation setup is a useful tool for a wide range of research applications.


Asunto(s)
Tomografía de Emisión de Positrones/instrumentación , Tomografía de Emisión de Positrones/veterinaria , Animales , Ratones , Método de Montecarlo , Fantasmas de Imagen/veterinaria , Ratas , Tomografía Computarizada de Emisión/instrumentación , Tomografía Computarizada de Emisión/veterinaria
14.
Vet Radiol Ultrasound ; 54(1): 9-16, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23293957

RESUMEN

It is important to optimize digital radiographic technique settings for small animal imaging in order to maximize image quality while minimizing radiation exposure to personnel. The purpose of this study was to evaluate two objective methods for determining optimal kVp values for an indirect flat panel digital detector. One method considered both image quality and personnel exposure as endpoints and one considered only image quality. Phantoms simulated veterinary patients of varying thicknesses with lesions of varying sizes. Phantoms were exposed to a range of kVp values (60, 81, 100, and 121), using different mAs settings for each phantom. Additionally, all phantoms were exposed to a standard test exposure of 100 kVp/2.5 mAs. Scattered radiation was recorded and used as a measure of personnel exposure. When personnel exposure was considered, a figure of merit was calculated as an endpoint of optimization. The optimal kVp value for each phantom was determined based on the highest signal difference-to-noise ratio with or without inclusion of the figure of merit. When personnel exposure was not considered, increasing kVp resulted in higher signal difference-to-noise ratios and personnel exposure increased when both patient thickness and kVp increased. Findings indicated that a single standard technique of 100 kVp/2.5 mAs was only optimal for most medium-sized patients. Images of thinner patients should be made with a lower kVp. Very large patients require a higher kVp than 100 regardless of the optimization method used. Personnel exposure from optimized techniques was low and not expected to exceed annual occupational dose limits.


Asunto(s)
Técnicos de Animales , Exposición Profesional/prevención & control , Fantasmas de Imagen/normas , Monitoreo de Radiación/instrumentación , Intensificación de Imagen Radiográfica/métodos , Animales , Humanos , Fantasmas de Imagen/veterinaria , Control de Calidad , Dosis de Radiación , Monitoreo de Radiación/métodos , Intensificación de Imagen Radiográfica/instrumentación , Valores de Referencia , Relación Señal-Ruido
15.
Magn Reson Imaging ; 30(8): 1186-91, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22770689

RESUMEN

The increasing availability of rodent models of human cardiovascular disease has led to a need to translate noninvasive imaging techniques such as magnetic resonance imaging (MRI) from the clinic to the animal laboratory. The aim of this study was to develop phantoms simulating the short-axis view of left ventricular motion of rats and mice, thus reducing the need for live animals in the development of MRI. Cylindrical phantoms were moulded from polyvinyl alcohol (PVA) Cryogel and attached via stiff water-filled tubing to a gear pump. Pulsatile distension of the phantoms was effected by suitable programming of the pump. Cine MRI scanning was carried out at 7 T and compared with in vivo rodent cardiac imaging. Suitable pulsatile performance was achieved with phantoms for which the PVA material had been subjected to two freeze-thaw cycles, resulting in T1 and T2 relaxation time constants of 1656±124 ms and 55±10 ms, respectively. For the rat phantom operating at 240 beats per min (bpm), the dynamic range of the outer diameter was from 10.3 to 12.4 mm with the wall thickness varying between 1.9 and 1.2 mm. Corresponding figures for the mouse phantom at 480 bpm were outer diameter range from 5.4 to 6.4 mm and wall thickness from 1.5 to 1.2 mm. Dynamic cardiac phantoms simulating rodent left ventricular motion in the short-axis view were successfully developed and compared with in vivo imaging. The phantoms can be used for future development work with reduced need of live animals.


Asunto(s)
Corazón/anatomía & histología , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/veterinaria , Modelos Animales , Fantasmas de Imagen/veterinaria , Animales , Diseño de Equipo , Análisis de Falla de Equipo , Ratones , Ratas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
16.
Phys Med Biol ; 57(12): 3981-93, 2012 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-22647967

RESUMEN

Quantification accuracy and partial volume effect (PVE) of the Siemens Inveon PET scanner were evaluated. The influence of transmission source activities (40 and 160 MBq) on the quantification accuracy and the PVE were determined. Dynamic range, object size and PVE for different sphere sizes, contrast ratios and positions in the field of view (FOV) were evaluated. The acquired data were reconstructed using different algorithms and correction methods. The activity level of the transmission source and the total emission activity in the FOV strongly influenced the attenuation maps. Reconstruction algorithms, correction methods, object size and location within the FOV had a strong influence on the PVE in all configurations. All evaluated parameters potentially influence the quantification accuracy. Hence, all protocols should be kept constant during a study to allow a comparison between different scans.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Tomografía de Emisión de Positrones/veterinaria , Animales , Fantasmas de Imagen/veterinaria , Tomografía de Emisión de Positrones/métodos
17.
Phys Med Biol ; 57(12): N199-207, 2012 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-22617214

RESUMEN

Small-animal positron-emission tomography/computed tomography (PET/CT) scanners provide anatomical and molecular imaging, which enables the joint visualization and analysis of both types of data. A proper alignment calibration procedure is essential for small-animal imaging since resolution is much higher than that in human devices. This work presents an alignment phantom and two different calibration methods that provide a reliable and repeatable measurement of the spatial geometrical alignment between the PET and the CT subsystems of a hybrid scanner. The phantom can be built using laboratory materials, and it is meant to estimate the rigid spatial transformation that aligns both modalities. It consists of three glass capillaries filled with a positron-emitter solution and positioned in a non-coplanar triangular geometry inside the system field of view. The calibration methods proposed are both based on automatic line detection, but with different approaches to calculate the transformation of the lines between both modalities. Our results show an average accuracy of the alignment estimation of 0.39 mm over the whole field of view.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/instrumentación , Imagen Multimodal/veterinaria , Fantasmas de Imagen/veterinaria , Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X , Animales , Tamaño Corporal , Calibración , Imagen Multimodal/instrumentación , Reproducibilidad de los Resultados
18.
Vet Radiol Ultrasound ; 53(5): 507-12, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22612282

RESUMEN

A major disadvantage of computed tomography for abdominal screening in dogs has been the need for general anesthesia to prevent motion artifacts. With multidetector helical CT, it is possible to decrease examination time, allowing patients to be scanned under sedation. It is also desirable to decrease tube loading to prolong x-ray tube life. To develop a protocol that will allow for examination of sedated patients with minimal image artifacts, milliamperage (mA) and helical pitch were varied, providing 16 experimental scan protocols. A standard clinical protocol was also tested, providing 17 protocols for evaluation. These protocols were tested, using a standard CT phantom, canine tissues in a water bath, and a canine cadaver. The cadaver images were scored semiquantitatively by three reviewers to determine the protocol with the best combination of speed and minimal image artifact. The optimized protocol was then applied to 27 sedated canine patients of three body weight categories. The images obtained were compared to the standard protocol by two reviewers for presence of motion, streak, and quantum mottle artifacts. There was significantly more streak artifact noted by one observer using the optimized study protocol, but no significant difference in any other category. Scanning under sedation was well tolerated in all patients, and sedated CT examination is a promising tool for screening abdominal disease in dogs.


Asunto(s)
Artefactos , Medios de Contraste , Perros/anatomía & histología , Tomografía Computarizada Multidetector/veterinaria , Radiografía Abdominal/veterinaria , Animales , Sedación Consciente/veterinaria , Hígado/diagnóstico por imagen , Fantasmas de Imagen/veterinaria , Intensificación de Imagen Radiográfica , Bazo/diagnóstico por imagen
19.
Vet Radiol Ultrasound ; 53(3): 312-7, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22277053

RESUMEN

Magnetic resonance imaging (MRI) artifacts secondary to metallic implants and foreign bodies are well described. Herein, we provide quantitative data from veterinary implants including total hip arthroplasty implants, cranial cruciate repair implants, surgical screws, a skin staple, ligation clips, an identification microchip, ameroid constrictor, and potential foreign bodies including air gun and BB projectiles and a sewing needle. The objects were scanned in a gelatin phantom with plastic grid using standardized T2-weighted turbo-spin echo (TSE), T1-weighted spin echo, and T2*-weighted gradient recalled echo (GRE) image acquisitions at 1.5 T. Maximum linear dimensions and areas of signal voiding and grid distortion were calculated using a DICOM workstation for each sequence and object. Artifact severity was similar between the T2-weighted TSE and T1-weighted images, while the T2*-weighted images were most susceptible to artifact. Metal type influenced artifact size with the largest artifacts arising from steel objects followed by surgical stainless steel, titanium, and lead. For animals with metallic surgical implants or foreign bodies, the quantification of the artifact size will help guide clinicians on the viability of MRI.


Asunto(s)
Cuerpos Extraños/veterinaria , Imagen por Resonancia Magnética/veterinaria , Metales , Fantasmas de Imagen/veterinaria , Prótesis e Implantes/veterinaria , Animales , Artefactos , Cuerpos Extraños/diagnóstico
20.
Vet Radiol Ultrasound ; 53(1): 96-100, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22092982

RESUMEN

Bolus material is used commonly with electron treatments. The purpose of this study was to compare the electron beam attenuating properties of SuperFlab, Play-Doh, and wet gauze to that of plastic water, and evaluate their characteristics as bolus materials for electron beam therapy. Electron beams of 5, 6, 7, 8, 10, and 12 MeV were used. Dose reduction from a range of bolus thicknesses from 2 mm to a thickness well beyond the thickness required to reach peak ioization was measured for each of the bolus materials to establish independent isodose curves. Measurements performed at the known water Dmax for all bolus materials indicated similar results for SuperFlab and plastic water with less than 3% difference for most energies. Play-Doh resulted in more attenuation or less dose buildup compared with plastic water, especially at lower energies. The difference was as high as 24.7% for the beam energy of 5 MeV for Play-Doh. Evaluation of the dose build up curves for all materials indicated the peak dose build up for wet gauze and Play-Doh occurred at lesser thicknesses compared to plastic water and SuperFlab, particularly at lower energies. If Play-Doh and wet gauze are to be used for electron bolus materials, dose build up curves should be established for the machine being used and the appropriate thickness of bolus material be chosen based on those curves.


Asunto(s)
Electrones/uso terapéutico , Aceleradores de Partículas , Fantasmas de Imagen/veterinaria , Dosificación Radioterapéutica/veterinaria , Radioterapia de Alta Energía/veterinaria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA