Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.569
Filtrar
1.
Sci Rep ; 14(1): 10055, 2024 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-38698058

RESUMEN

Endoscopic transgastric necrosectomy is crucial in the management of complications resulting from necrotizing pancreatitis. However, both real-time and visual-spatial information is lacking during the procedure, thereby jeopardizing a precise positioning of the endoscope. We conducted a proof-of-concept study with the aim of overcoming these technical difficulties. For this purpose, a three-dimensional (3D) phantom of a stomach and pancreatic necroses was 3D-printed based on spatial information from individual patient CT scans and subsequently integrated into a silicone torso. An electromagnetic (EM) sensor was adjusted inside the endoscope´s working channel. A software interface enabled real time visualization. The accuracy of this novel assistant system was tested ex vivo by four experienced interventional endoscopists who were supposed to reach seven targets inside the phantom in six different experimental runs of simulated endoscopic transgastric necrosectomy. Supported by endoscopic camera view combined with real-time 3D visualization, all endoscopists reached the targets with a targeting error ranging between 2.6 and 6.5 mm in a maximum of eight minutes. In summary, the EM tracking system might increase efficacy and safety of endoscopic transgastric necrosectomy at the experimental level by enhancing visualization. Yet, a broader feasibility study and further technical improvements are mandatory before aiming at implementation into clinical setting.


Asunto(s)
Fenómenos Electromagnéticos , Humanos , Fantasmas de Imagen , Estómago/cirugía , Estómago/diagnóstico por imagen , Pancreatitis Aguda Necrotizante/cirugía , Pancreatitis Aguda Necrotizante/diagnóstico por imagen , Endoscopía/métodos , Páncreas/cirugía , Impresión Tridimensional , Sistemas de Navegación Quirúrgica , Imagenología Tridimensional/métodos
2.
Otolaryngol Pol ; 78(2): 50-54, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38623855

RESUMEN

<b><br>Aim:</b> The aim of the study was to evaluate the results of electrical safety results of a prototype electromagnetic ear stimulation device in patients with tinnitus.</br> <b><br>Material and methods:</b> The electrical safety tests of the prototype device for electro- and magnetostimulation of the hearing organ were carried out at the Center for Attestation and Certification Tests in Gliwice. The tests concerned selected parameters including the PN-EN standard.</br> <b><br>Results:</b> Safety studies of the prototype electrical stimulation device for the ear in patients with tinnitus were necessary to perform the planned further preclinical studies. Obtained results regarding: identification and labeling of the device; protection against electric shock; checking protective earthing, functional earthing and potential equalization; checking the leakage current and auxiliary currents of the patient; checking the distances through the solid insulation and the use of thin insulating spacers; checking the electrical strength of the device insulation; checking protection against mechanical hazards of the device; checking the risk associated with surfaces, corners and edges, and checking the protection against excessive temperatures and other threats comply with the standard PN-EN.</br> <b><br>Conclusions:</b> No risk to the patient and medical staff. Tests of protection against mechanical hazards of the device have shown that the only movable part whose contact with the patient could cause an unacceptable risk is the fan installed inside the housing.</br>.


Asunto(s)
Acúfeno , Humanos , Acúfeno/terapia , Fenómenos Electromagnéticos
3.
J Robot Surg ; 18(1): 149, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38564059

RESUMEN

Pulmonary nodules are frequently encountered in high-risk patients. Often these require biopsy which can be challenging. We relate our experience comparing use of electromagnetic navigational bronchoscopy (ENB) to a robotic bronchoscopy system (RB). A retrospective review of patients undergoing bronchoscopic biopsy from 2015 to 2021. The timeframe overlapped with transition from ENB using Veran SPiN system to RB using Ion system by Intuitive. Patient and nodule characteristics were collected. Primary end point was overall diagnostic yield which was defined by pathologic confirmation of malignancy or benign finding. Secondary outcomes included diagnostic yield based on overall size of nodules and need for further work up and testing. 116 patients underwent ENB or RB of 134 nodules. No perioperative complications occurred. Diagnostic yield of ENB was 49.5% (41/91 nodules) versus 86.1% (37/43 nodules) for RB. Average nodule size for ENB was 2.55 cm versus 1.96 cm for RB. When divided based on size, ENB had a 30% diagnostic yield for nodules 1-2 cm (11/37 nodules, mean size 1.46 cm) and 64% yield for nodules 2-3 cm (14/22 nodules, mean size 2.38 cm). RB had an 81% yield for nodules 1-2 cm (mean size 1.41 cm) and 100% yield for nodules 2-3 cm (mean 2.3 cm). RB showed superiority over ENB in early implementation trials for biopsy of suspicious pulmonary nodules. It is a safe technology allowing for increased access to all lung fields and utilization in the thoracic surgical practice will be paramount to advancing the field.


Asunto(s)
Procedimientos Quirúrgicos Robotizados , Cirugía Torácica , Humanos , Broncoscopía , Procedimientos Quirúrgicos Robotizados/métodos , Biopsia , Fenómenos Electromagnéticos
4.
BMJ Open Ophthalmol ; 9(1)2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38575345

RESUMEN

OBJECTIVE: Preclinical validation study to assess the feasibility and accuracy of electromagnetic image-guided systems (EM-IGS) in orbital surgery using high-fidelity physical orbital anatomy simulators. METHODS: EM-IGS platform, clinical software, navigation instruments and reference system (StealthStation S8, Medtronic) were evaluated in a mock operating theatre at the Royal Victoria Eye and Ear Hospital, a tertiary academic hospital in Dublin, Ireland. Five high-resolution 3D-printed model skulls were created using CT scans of five anonymised patients with an orbital tumour that previously had a successful orbital biopsy or excision. The ability of ophthalmic surgeons to achieve satisfactory system registration in each model was assessed. Subsequently, navigational accuracy was recorded using defined anatomical landmarks as ground truth. Qualitative feedback on the system was also attained. RESULTS: Three independent surgeons participated in the study, one junior trainee, one fellow and one consultant. Across models, more senior participants were able to achieve a smaller system-generated registration error in a fewer number of attempts. When assessing navigational accuracy, submillimetre accuracy was achieved for the majority of points (16 landmarks per model, per participant). Qualitative surgeon feedback suggested acceptability of the technology, although interference from mobile phones near the operative field was noted. CONCLUSION: This study suggests the feasibility and accuracy of EM-IGS in a preclinical validation study for orbital surgery using patient specific 3D-printed skulls. This preclinical study provides the foundation for clinical studies to explore the safety and effectiveness of this technology.


Asunto(s)
Cirugía Asistida por Computador , Humanos , Órbita/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Programas Informáticos , Fenómenos Electromagnéticos
5.
Hum Brain Mapp ; 45(5): e26638, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38520365

RESUMEN

Connectome spectrum electromagnetic tomography (CSET) combines diffusion MRI-derived structural connectivity data with well-established graph signal processing tools to solve the M/EEG inverse problem. Using simulated EEG signals from fMRI responses, and two EEG datasets on visual-evoked potentials, we provide evidence supporting that (i) CSET captures realistic neurophysiological patterns with better accuracy than state-of-the-art methods, (ii) CSET can reconstruct brain responses more accurately and with more robustness to intrinsic noise in the EEG signal. These results demonstrate that CSET offers high spatio-temporal accuracy, enabling neuroscientists to extend their research beyond the current limitations of low sampling frequency in functional MRI and the poor spatial resolution of M/EEG.


Asunto(s)
Conectoma , Humanos , Conectoma/métodos , Electroencefalografía/métodos , Encéfalo/diagnóstico por imagen , Encéfalo/fisiología , Imagen por Resonancia Magnética/métodos , Fenómenos Electromagnéticos
7.
ACS Appl Mater Interfaces ; 16(11): 13597-13610, 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38453642

RESUMEN

Atmospheric pressure coaxial gaseous discharge tubes (DTs) with helium have demonstrated potential for in vitro inactivation or sensitization of glioblastoma cancer cells. Here, we study the effect of two configurations of the DT electrode system on its electromagnetic emissivity as well as other physical factors (heating and UV emission) that form in the vicinity of this device. We demonstrate that the configuration of the DT electrodes that concentrates the discharge streamers near the top of the device has a distant (cm scale) deactivation effect on U87-MG glioblastoma cancer cells when irradiated, without measurable UV components in the DT optical emission spectra. This effect persists even through different barriers such as glass, plastic, or quartz Petri dishes but is eliminated when glass or plastic dishes are filled with water. These findings demonstrate the potential for development of noninvasive, physical-based treatment methods of deep-tissue tumors.


Asunto(s)
Glioblastoma , Gases em Plasma , Humanos , Gases em Plasma/farmacología , Helio , Glioblastoma/terapia , Fenómenos Electromagnéticos , Presión Atmosférica
8.
Proc Natl Acad Sci U S A ; 121(11): e2312761121, 2024 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-38446852

RESUMEN

By masterfully balancing directed growth and passive mechanics, plant roots are remarkably capable of navigating complex heterogeneous environments to find resources. Here, we present a theoretical and numerical framework which allows us to interrogate and simulate the mechanical impact of solid interfaces on the growth pattern of plant organs. We focus on the well-known waving, coiling, and skewing patterns exhibited by roots of Arabidopsis thaliana when grown on inclined surfaces, serving as a minimal model of the intricate interplay with solid substrates. By modeling growing slender organs as Cosserat rods that mechanically interact with the environment, our simulations verify hypotheses of waving and coiling arising from the combination of active gravitropism and passive root-plane responses. Skewing is instead related to intrinsic twist due to cell file rotation. Numerical investigations are outfitted with an analytical framework that consistently relates transitions between straight, waving, coiling, and skewing patterns with substrate tilt angle. Simulations are found to corroborate theory and recapitulate a host of reported experimental observations, thus providing a systematic approach for studying in silico plant organs behavior in relation to their environment.


Asunto(s)
Arabidopsis , Ciclo Celular , Proliferación Celular , Fenómenos Electromagnéticos , Raíces de Plantas
9.
Int J Biol Macromol ; 265(Pt 2): 130957, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38499121

RESUMEN

Deterioration in mechanical performances and aging resistance due to the introduction of flame retardants is a major obstacle for bio-based fire-safety polypropylene (PP). Herein, we reported a kind of functionalized lignin nanoparticles assembled with MXene (MX@LNP), and applied it to construct the flame-retardant PP composites (PP-MA) with superior fire safety, excellent mechanical performance, electromagnetic shielding effects and aging resistance. Specifically, the PP-MA doped with only 18 wt% flame-retardant additives (PP-MA18) achieved the UL-94 V-0 rating. In comparison to pure PP, PP-MA18 presented a greatly decreased peak of heat release rate (pHRR), total heat rate (THR), and peak smoke production rate (pSPR) by 79.7 %, 69.0 % and 75.8 %, respectively, and satisfactory decrease in total flammable and toxic volatiles evolved. The formed fine solid microstructure of carbon residuals effectively promoted the compactness of char layers. More importantly, the nano-effect and the strong interface interaction between the complexed MX@LNP and PP enhanced the tensile strength (45.78 MPa) and elongation at break (725.95 %) of PP-MA. Additionally, the significant ultraviolet absorption and electromagnetic wave dissipation performance of MXene and lignin enabled excellent aging resistance and electromagnetic shielding effects of PP-MA compared with PP. This achieved MX@LNP afforded a novel approach for developing flame retardant materials with excellent application performance.


Asunto(s)
Retardadores de Llama , Nanopartículas , Nitritos , Elementos de Transición , Lignina , Polipropilenos , Fenómenos Electromagnéticos
10.
Nanomedicine ; 57: 102742, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38460654

RESUMEN

Modification of T-lymphocytes, which are capable of paracellular transmigration is a promising trend in modern personalized medicine. However, the delivery of required concentrations of functionalized T-cells to the target tissues remains a problem. We describe a novel method to functionalize T-cells with magnetic nanocapsules and target them with electromagnetic tweezers. T-cells were modified with the following magnetic capsules: Parg/DEX (150 nm), BSA/TA (300 nm), and BSA/TA (500 nm). T-cells were magnetonavigated in a phantom blood vessel capillary in cultural medium and in whole blood. The permeability of tumor tissues to captured T-cells was analyzed by magnetic delivery of modified T-cells to spheroids formed from 4T1 breast cancer cells. The dynamics of T-cell motion under a magnetic field gradient in model environments were analyzed by particle image velocimetry. The magnetic properties of the nanocomposite capsules and magnetic T-cells were measured. The obtained results are promising for biomedical applications in cancer immunotherapy.


Asunto(s)
Nanocápsulas , Nanocompuestos , Sistemas de Liberación de Medicamentos/métodos , Linfocitos T , Fenómenos Electromagnéticos , Cápsulas
11.
Med Eng Phys ; 125: 104116, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38508792

RESUMEN

The purpose of this study was to evaluate the accuracy of a method for estimating the tip position of a fiber optic shape-sensing (FOSS) integrated instrument being inserted through a bronchoscope. A modified guidewire with a multicore optical fiber was inserted into the working channel of a custom-made catheter with three electromagnetic (EM) sensors. The displacement between the instruments was manually set, and a point-based method was applied to match the position of the EM sensors to corresponding points on the shape. The accuracy was evaluated in a realistic bronchial model. An additional EM sensor was used to sample the tip of the guidewire, and the absolute deviation between this position and the estimated tip position was calculated. For small displacements between the tip of the FOSS integrated tool and the catheter, the median deviation in estimated tip position was ≤5 mm. For larger displacements, deviations exceeding 10 mm were observed. The deviations increased when the shape sensor had sharp curvatures relative to more straight shapes. The method works well for clinically relevant displacements of a biopsy tool from the bronchoscope tip, and when the path to the lesion has limited curvatures. However, improvements must be made to our configuration before pursuing further clinical testing.


Asunto(s)
Broncoscopía , Fenómenos Electromagnéticos , Broncoscopía/métodos , Fantasmas de Imagen , Catéteres
12.
BMC Pulm Med ; 24(1): 108, 2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-38438922

RESUMEN

BACKGROUND: Safely implementing transbronchial lung cryobiopsy (TBLC) in patients with interstitial lung disease (ILD) requires accurate navigation. Traditional fluoroscopy falls short in reducing the risk of post-procedure pneumothorax. The potential of electromagnetic navigation bronchoscopy (ENB) as a more precise navigation method warrants further exploration. METHODS: A prospective cohort study was conducted on ILD patients undergoing TBLC. Patients were assigned either fluoroscopy or ENB for cryoprobe positioning. Navigation accuracy was evaluated using cone beam computed tomography (CBCT) images as the standard. Safety and diagnostic yield were also observed. RESULTS: Seventeen patients underwent TBLC, with 10 guided by fluoroscopy and seven by ENB. Fluoroscopy-guided cryoprobe navigation required more adjustments [9/15 (60%) v.s. 1/9 (11%), p = 0.018] for subsequent TBLC compared to ENB, as confirmed by CBCT images. Clinical characteristics, post-procedure complications, and biopsy specimen size showed no significant differences between the groups. Fourteen patients obtained a pathological diagnosis, and 15 received a multidisciplinary discussion (MDD) diagnosis. In the fluoroscopy group, three patients failed to obtain a pathological diagnosis, and two failed to obtain an MDD diagnosis. CONCLUSIONS: ENB demonstrates significantly superior accuracy in TBLC navigation compared to traditional fluoroscopy when CBCT images are used as a reference. Further studies are necessary to determine the value of ENB in TBLC navigation for ILD patients.


Asunto(s)
Broncoscopía , Enfermedades Pulmonares Intersticiales , Humanos , Estudios Prospectivos , Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Fluoroscopía , Pulmón/diagnóstico por imagen , Fenómenos Electromagnéticos
13.
Sci Rep ; 14(1): 5760, 2024 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-38459073

RESUMEN

Stroke is a leading cause of death and disability worldwide, and early diagnosis and prompt medical intervention are thus crucial. Frequent monitoring of stroke patients is also essential to assess treatment efficacy and detect complications earlier. While computed tomography (CT) and magnetic resonance imaging (MRI) are commonly used for stroke diagnosis, they cannot be easily used onsite, nor for frequent monitoring purposes. To meet those requirements, an electromagnetic imaging (EMI) device, which is portable, non-invasive, and non-ionizing, has been developed. It uses a headset with an antenna array that irradiates the head with a safe low-frequency EM field and captures scattered fields to map the brain using a complementary set of physics-based and data-driven algorithms, enabling quasi-real-time detection, two-dimensional localization, and classification of strokes. This study reports clinical findings from the first time the device was used on stroke patients. The clinical results on 50 patients indicate achieving an overall accuracy of 98% in classification and 80% in two-dimensional quadrant localization. With its lightweight design and potential for use by a single para-medical staff at the point of care, the device can be used in intensive care units, emergency departments, and by paramedics for onsite diagnosis.


Asunto(s)
Encéfalo , Accidente Cerebrovascular , Humanos , Encéfalo/diagnóstico por imagen , Fenómenos Electromagnéticos , Cabeza , Accidente Cerebrovascular/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Imagen por Resonancia Magnética
14.
Sci Rep ; 14(1): 5940, 2024 03 11.
Artículo en Inglés | MEDLINE | ID: mdl-38467672

RESUMEN

Microwave thermal ablation is an established therapeutic technique for treating malignant tissue in various organs. Its success greatly depends on the knowledge of dielectric properties of the targeted tissue and on how they change during the treatment. Innovation in lung navigation has recently increased the clinical interest in the transbronchial microwave ablation treatment of lung cancer. However, lung tissue is not largely characterized, thus its dielectric properties investigation prior and post ablation is key. In this work, dielectric properties of ex-vivo ovine lung parenchyma untreated and ablated at 2.45 GHz were recorded in the 0.5-8 GHz frequency range. The measured dielectric properties were fitted to 2-pole Cole-Cole relaxation model and the obtained model parameters were compared. Based on observed changes in the model parameters, the physical changes of the tissue post-ablation were discussed and validated through histology analysis. Additionally, to investigate the link of achieved results with the rate of heating, another two sets of samples, originating from both ovine and porcine tissues, were heated with a microwave oven for different times and at different powers. Dielectric properties were measured in the same frequency range. It was found that lung tissue experiences a different behavior according to heating rates: its dielectric properties increase post-ablation while a decrease is found for low rates of heating. It is hypothesized, and validated by histology, that during ablation, although the tissue is losing water, the air cavities deform, lowering air content and increasing the resulting tissue properties.


Asunto(s)
Calor , Microondas , Ovinos , Animales , Porcinos , Microondas/uso terapéutico , Oveja Doméstica , Pulmón , Fenómenos Electromagnéticos , Hígado
15.
World J Urol ; 42(1): 124, 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38453751

RESUMEN

BACKGROUND: Extracorporeal shock wave lithotripsy represents one option for the non-surgical management of Peyronie's disease. Despite promising results, several questions are still pending. We want to present the long-term results of a retrospective study using high-energy extracorporeal shock wave lithotripsy. MATERIAL AND METHODS: We evaluated retrospectively 110 patients treated between 1996 and 2020 at the Department of Urology, SLK Kliniken Heilbronn for chronic phase Peyronie's disease using two electromagnetic lithotripters (Siemens Lithostar Plus Overhead Module, Siemens Lithoskop) applying high-energy shock waves under local anesthesia and sonographic or fluoroscopic control. A standardized questionnaire focused on the change in pain, curvature, sexual function and the need of penile surgery. RESULTS: In 85 of the 110 patients (mean age 54 years) we had sufficient data for evaluation. The median follow-up was 228 (6-288) months. There were no significant complications. Pain reduction was achieved in all patients, 65 (76%) patients were free of pain. Improvement of penile curvature was achieved in 43 patients (51%) ranging from 25% improvement (deflected angle < 30°) to 95% (angle 30-60°). 59 patients (69%) reported problems with sexual intercourse, 40 of those (68%) reported improvement. Only 9 (10.5%) patients underwent surgical correction. We did not observe any significant differences between both electromagnetic devices with stable long-term results. CONCLUSIONS: High-energy shock wave therapy delivered by two standard electromagnetic lithotripters is safe and efficient providing stable long-term results. In cases with significant plaque formation, the concept of high-energy ESWT should be considered in future studies.


Asunto(s)
Ondas de Choque de Alta Energía , Litotricia , Induración Peniana , Masculino , Humanos , Persona de Mediana Edad , Induración Peniana/terapia , Estudios Retrospectivos , Pene , Dolor , Fenómenos Electromagnéticos , Resultado del Tratamiento
16.
Med Phys ; 51(5): 3184-3194, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38456608

RESUMEN

BACKGROUND: Electromagnetic tracking (EMT) systems have proven to be a valuable source of information regarding the location and geometry of applicators in patients undergoing brachytherapy (BT). As an important element of an enhanced and individualized pre-treatment verification, EMT can play a pivotal role in detecting treatment errors and uncertainties to increase patient safety. PURPOSE: The purpose of this study is two-fold: to design, develop and test a dedicated measurement protocol for the use of EMT-enabled afterloaders in BT and to collect and compare the data acquired from three different radiation oncology centers in different clinical environments. METHODS: A novel quality assurance (QA) phantom composed of a scaffold with supports to fix the field generator, different BT applicators, and reference sensors (sensor verification tools) was used to assess the precision (jitter error) and accuracy (relative distance errors and target registration error) of the EMT sensor integrated into an afterloader prototype. Measurements were repeated in different environments where EMT measurements are likely to be performed, namely an electromagnetically clean laboratory, a BT suite, an operating room, and, if available, a CT suite and an MRI suite dedicated to BT. RESULTS: The mean positional jitter was consistently under 0.1 mm across all measurement points, with a slight trend of increased jitter at greater distances from the field generator. The mean variability of sensor positioning in the tested tandem and ring gynecological applicator was also below 0.1 mm. The tracking accuracy close to the center of the measurement volume was higher than at its edges. The relative distance error at the center was 0.2-0.3 mm with maximum values reaching 1.2-1.8 mm, but up to 5.5 mm for measurement points close to the edges. In general, similar accuracy results were obtained in the clinical environments and in all investigated institutions (median distance error 0.1-0.4 mm, maximum error 1.0-2.0 mm), however, errors were found to be larger in the CT suite (median distance error up to 1.0 mm, maximum error up to 3.6 mm). CONCLUSION: The presented quality assessment protocol for EMT systems in BT has demonstrated that EMT offers a high-accuracy determination of the applicator/implant geometry even in clinical environments. In addition to that, it has provided valuable insights into the performance of EMT-enabled afterloaders across different radiation oncology centers.


Asunto(s)
Braquiterapia , Fenómenos Electromagnéticos , Garantía de la Calidad de Atención de Salud , Braquiterapia/instrumentación , Humanos , Fantasmas de Imagen , Control de Calidad
17.
Int J Biol Macromol ; 262(Pt 2): 130212, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38365142

RESUMEN

A novel electromagnetic heat extraction method was presented, whereby mandarin peels residue solution was located in a winding coil subjected to an oscillating magnetic field, and the pectin was extracted under appropriate conditions. Numerical relationships between applied magnetic field and induced electric field (IEF) in the extraction process were elaborated. The results showed that the induced current density, IEF and terminal temperature increased with increasing magnetic field. The maximum current density of 0.35 A/cm corresponds to the highest terminal temperature of 84.6 °C and IEF intensity of 26.6 V/cm. When magnetic field intensity was 1.39 T and the extraction time was 15 min, the maximum yield of pectin reached 9.16 %. In addition, all treatments impacted the ash content, protein content, water-holding capacity (WHC), and oil-holding capacity (OHC) of the obtained pectin. The pectin extracted by electromagnetic heat had the lowest DE value of 71.3 % with 126.55 kDa molecular weight, while the GalA content was at the highest level of 76.18 %. After different treatments, the composition of pectin monosaccharides changed, but there were slight differences in the composition of pectin polysaccharides. Moreover, the electromagnetic heat extracted pectin had light color and an obvious surface fragmentation of the peel residue.


Asunto(s)
Calor , Pectinas , Pectinas/química , Polisacáridos , Monosacáridos , Fenómenos Electromagnéticos
18.
Curr Oncol ; 31(2): 962-974, 2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38392066

RESUMEN

BACKGROUND: Stereotactic Body Radiotherapy (SBRT) is as a standard treatment for prostate cancer (PCa). Tight margins and high dose gradients are needed, and the precise localization of the target is mandatory. Our retrospective study reports our experience regarding the evaluation of intrafraction prostate motion during LINAC-based SBRT evaluated with a novel electromagnetic (EM) tracking device. This device consists of an integrated Foley catheter with a transmitter connected to a receiver placed on the treatment table. METHODS: We analyzed 31 patients who received LINAC-based SBRT using flattening filter-free (FFF) volumetric modulated arc therapy (VMAT). The patients were scheduled to be treated for primary (n = 27) or an intraprostatic recurrent PCa (n = 4). A simulation CT scan was conducted while the patients had a filled bladder (100-150 cc) and an empty rectum, and an EM tracking device was used. The same rectal and bladder conditions were employed during the treatment. The patients received 36.25 Gy delivered over five consecutive fractions on the whole prostate and 40 Gy on the nodule(s) visible via MRI, both delivered with a Simultaneous Integrated Boost approach. The CTV-to-PTV margin was 2 mm for both the identified treatment volumes. Patient positioning was verified with XVI ConeBeam-CT (CBCT) matching before each fraction. When the signals exceeded a 2 mm threshold in any of the three spatial directions, the treatment was manually interrupted. A new XVI CBCT was performed if this offset lasted >20 s. RESULTS: We analyzed data about 155 fractions. The median and mean treatment times, calculated per fraction, were 10 m31 s and 12 m44 s (range: 6 m36 s-65 m28 s), and 95% of the fractions were delivered with a maximum time of 27 m48 s. During treatment delivery, the mean and median number of XVI CBCT operations realized during the treatment were 2 and 1 (range: 0-11). During the treatment, the prostate was outside the CTV-to-PTV margin (2 mm), thus necessitating the stoppage of the delivery +/- a reacquisition of the XVI CBCT for 11.2%, 8.9%, and 3.9% of the delivery time in the vertical, longitudinal, and lateral direction, respectively. CONCLUSIONS: We easily integrated an EM-transmitter-based gating for prostate LINAC-based SBRT into our normal daily workflow. Using this system, a 2 mm CTV-to-PTV margin could be safely applied. A small number of fractions showed a motion exceeding the predefined 2 mm threshold, which would have otherwise gone undetected without intrafraction motion management.


Asunto(s)
Próstata , Radiocirugia , Masculino , Humanos , Planificación de la Radioterapia Asistida por Computador , Estudios Retrospectivos , Fenómenos Electromagnéticos
19.
Bioelectromagnetics ; 45(4): 171-183, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38348647

RESUMEN

In recent years, an increasing number of studies have discussed the mechanisms of vestibular activation in strong magnetic field settings such as occur in a magnetic resonance imaging scanner environment. Amid the different hypotheses, the Lorentz force explanation currently stands out as the most plausible mechanism, as evidenced by activation of the vestibulo-ocular reflex. Other hypotheses have largely been discarded. Nonetheless, both human data and computational modeling suggest that electromagnetic induction could be a valid mechanism which may coexist alongside the Lorentz force. To further investigate the induction hypothesis, we provide, herein, a first of its kind dosimetric analysis to estimate the induced electric fields at the vestibular system and compare them with what galvanic vestibular stimulation would generate. We found that electric fields strengths from induction match galvanic vestibular stimulation strengths generating vestibular responses. This review examines the evidence in support of electromagnetic induction of vestibular responses, and whether movement-induced time-varying magnetic fields should be further considered and investigated.


Asunto(s)
Reflejo Vestibuloocular , Vestíbulo del Laberinto , Humanos , Estimulación Eléctrica/métodos , Reflejo Vestibuloocular/fisiología , Vestíbulo del Laberinto/fisiología , Fenómenos Electromagnéticos , Imagen por Resonancia Magnética
20.
Phys Med Biol ; 69(5)2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38316038

RESUMEN

Objective.In our recent work pertinent to modeling of brain stimulation and neurophysiological recordings, substantial modeling errors in the computed electric field and potential have sometimes been observed for standard multi-compartment head models. The goal of this study is to quantify those errors and, further, eliminate them through an adaptive mesh refinement (AMR) algorithm. The study concentrates on transcranial magnetic stimulation (TMS), transcranial electrical stimulation (TES), and electroencephalography (EEG) forward problems.Approach.We propose, describe, and systematically investigate an AMR method using the boundary element method with fast multipole acceleration (BEM-FMM) as the base numerical solver. The goal is to efficiently allocate additional unknowns to critical areas of the model, where they will best improve solution accuracy. The implemented AMR method's accuracy improvement is measured on head models constructed from 16 Human Connectome Project subjects under problem classes of TES, TMS, and EEG. Errors are computed between three solutions: an initial non-adaptive solution, a solution found after applying AMR with a conservative refinement rate, and a 'silver-standard' solution found by subsequent 4:1 global refinement of the adaptively-refined model.Main results.Excellent agreement is shown between the adaptively-refined and silver-standard solutions for standard head models. AMR is found to be vital for accurate modeling of TES and EEG forward problems for standard models: an increase of less than 25% (on average) in number of mesh elements for these problems, efficiently allocated by AMR, exposes electric field/potential errors exceeding 60% (on average) in the solution for the unrefined models.Significance.This error has especially important implications for TES dosing prediction-where the stimulation strength plays a central role-and for EEG lead fields. Though the specific form of the AMR method described here is implemented for the BEM-FMM, we expect that AMR is applicable and even required for accurate electromagnetic simulations by other numerical modeling packages as well.


Asunto(s)
Cabeza , Plata , Humanos , Cabeza/fisiología , Estimulación Magnética Transcraneal/métodos , Electroencefalografía/métodos , Fenómenos Electromagnéticos , Encéfalo/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...