Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 14.811
Filtrar
1.
PLoS One ; 19(5): e0302142, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38722957

RESUMEN

We explore theoretically Goos-Hänchen (GH) shift around the defect mode in superconducting defective photonic crystals (PCs) in cryogenic environment. The defective PCs are constructed by alternating semiconductors and superconductors. A defect mode arises in the photonic bandgap and sensitively depends on environment temperature and hydrostatic pressure. Reflection and transmission coefficient phases make an abruptly jump at the defect mode and giant GH shifts have been achieved around this mode. The maximum GH shift can get as high as 103λ (incident wavelength), which could be modulated by the values of temperature and hydrostatic pressure. This study may be utilized for pressure- or temperature-sensors in cryogenic environment.


Asunto(s)
Fotones , Cristalización , Superconductividad , Semiconductores , Presión Hidrostática , Temperatura
2.
Neurosurg Focus ; 56(5): E9, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38691864

RESUMEN

OBJECTIVE: Chordomas are rare tumors of the skull base and spine believed to arise from the vestiges of the embryonic notochord. These tumors are locally aggressive and frequently recur following resection and adjuvant radiotherapy. Proton therapy has been introduced as a tissue-sparing option because of the higher level of precision that proton-beam techniques offer compared with traditional photon radiotherapy. This study aimed to compare recurrence in patients with chordomas receiving proton versus photon radiotherapy following resection by applying tree-based machine learning models. METHODS: The clinical records of all patients treated with resection followed by adjuvant proton or photon radiotherapy for chordoma at Mayo Clinic were reviewed. Patient demographics, type of surgery and radiotherapy, tumor recurrence, and other variables were extracted. Decision tree classifiers were trained and tested to predict long-term recurrence based on unseen data using an 80/20 split. RESULTS: Fifty-three patients with a mean ± SD age of 55.2 ± 13.4 years receiving surgery and adjuvant proton or photon therapy to treat chordoma were identified; most patients were male. Gross-total resection was achieved in 54.7% of cases. Proton therapy was the most common adjuvant radiotherapy (84.9%), followed by conventional or external-beam radiation therapy (9.4%) and stereotactic radiosurgery (5.7%). Patients receiving proton therapy exhibited a 40% likelihood of having recurrence, significantly lower than the 88% likelihood observed in those treated with nonproton therapy. This was confirmed on logistic regression analysis adjusted for extent of tumor resection and tumor location, which revealed that proton adjuvant radiotherapy was associated with a decreased risk of recurrence (OR 0.1, 95% CI 0.01-0.71; p = 0.047) compared with photon therapy. The decision tree algorithm predicted recurrence with an accuracy of 90% (95% CI 55.5%-99.8%), with the lowest risk of recurrence observed in patients receiving gross-total resection with adjuvant proton therapy (23%). CONCLUSIONS: Following resection, adjuvant proton therapy was associated with a lower risk of chordoma recurrence compared with photon therapy. The described machine learning models were able to predict tumor progression based on the extent of tumor resection and adjuvant radiotherapy modality used.


Asunto(s)
Cordoma , Recurrencia Local de Neoplasia , Fotones , Terapia de Protones , Neoplasias de la Columna Vertebral , Humanos , Cordoma/radioterapia , Cordoma/cirugía , Masculino , Femenino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/radioterapia , Terapia de Protones/métodos , Radioterapia Adyuvante/métodos , Adulto , Anciano , Neoplasias de la Columna Vertebral/radioterapia , Neoplasias de la Columna Vertebral/cirugía , Fotones/uso terapéutico , Estudios Retrospectivos , Resultado del Tratamiento
3.
Med Phys ; 51(5): 3796-3805, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38588477

RESUMEN

BACKGROUND: The Relative Biological Effectiveness (RBE) of kilovoltage photon beams has been previously investigated in vitro and in silico using analytical methods. The estimated values range from 1.03 to 1.82 depending on the methodology and beam energies examined. PURPOSE: The focus of this work was to independently estimate RBE values for a range of clinically used kilovoltage beams (70-200 kVp) while investigating the suitability of using TOPAS-nBio for this task. METHODS: Previously validated spectra of clinical beams were used to generate secondary electron spectra at several depths in a water tank phantom via TOPAS Monte Carlo (MC) simulations. Cell geometry was irradiated with the secondary electrons in TOPAS-nBio MC simulations. The deposited dose and the calculated number of DNA strand breaks were used to estimate RBE values. RESULTS: Monoenergetic secondary electron simulations revealed the highest direct and indirect double strand break yield at approximately 20 keV. The average RBE value for the kilovoltage beams was calculated to be 1.14. CONCLUSIONS: TOPAS-nBio was successfully used to estimate the RBE values for a range of clinical radiotherapy beams. The calculated value was in agreement with previous estimates, providing confidence in its clinical use in the future.


Asunto(s)
Roturas del ADN de Doble Cadena , Método de Montecarlo , Efectividad Biológica Relativa , Roturas del ADN de Doble Cadena/efectos de la radiación , Humanos , Electrones , Dosificación Radioterapéutica , Fotones , Simulación por Computador , Fantasmas de Imagen
4.
Sci Rep ; 14(1): 9358, 2024 04 23.
Artículo en Inglés | MEDLINE | ID: mdl-38653758

RESUMEN

The goal of this experimental study was to quantify the influence of helical pitch and gantry rotation time on image quality and file size in ultrahigh-resolution photon-counting CT (UHR-PCCT). Cervical and lumbar spine, pelvis, and upper legs of two fresh-frozen cadaveric specimens were subjected to nine dose-matched UHR-PCCT scan protocols employing a collimation of 120 × 0.2 mm with varying pitch (0.3/1.0/1.2) and rotation time (0.25/0.5/1.0 s). Image quality was analyzed independently by five radiologists and further substantiated by placing normed regions of interest to record mean signal attenuation and noise. Effective mAs, CT dose index (CTDIvol), size-specific dose estimate (SSDE), scan duration, and raw data file size were compared. Regardless of anatomical region, no significant difference was ascertained for CTDIvol (p ≥ 0.204) and SSDE (p ≥ 0.240) among protocols. While exam duration differed substantially (all p ≤ 0.016), the lowest scan time was recorded for high-pitch protocols (4.3 ± 1.0 s) and the highest for low-pitch protocols (43.6 ± 15.4 s). The combination of high helical pitch and short gantry rotation times produced the lowest perceived image quality (intraclass correlation coefficient 0.866; 95% confidence interval 0.807-0.910; p < 0.001) and highest noise. Raw data size increased with acquisition time (15.4 ± 5.0 to 235.0 ± 83.5 GByte; p ≤ 0.013). Rotation time and pitch factor have considerable influence on image quality in UHR-PCCT and must therefore be chosen deliberately for different musculoskeletal imaging tasks. In examinations with long acquisition times, raw data size increases considerably, consequently limiting clinical applicability for larger scan volumes.


Asunto(s)
Fotones , Humanos , Tomografía Computarizada por Rayos X/métodos , Cadáver , Rotación , Dosis de Radiación , Tomografía Computarizada Espiral/métodos
5.
Tomography ; 10(4): 543-553, 2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-38668400

RESUMEN

This study introduces an application of innovative medical technology, Photon Counting Computer Tomography (PC CT) with novel detectors, for the assessment of shunt valves. PC CT technology offers enhanced visualization capabilities, especially for small structures, and opens up new possibilities for detailed three-dimensional imaging. Shunt valves are implanted under the skin and redirect excess cerebrospinal fluid, for example, to the abdominal cavity through a catheter. They play a vital role in regulating cerebrospinal fluid drainage in various pathologies, which can lead to hydrocephalus. Accurate imaging of shunt valves is essential to assess the rate of drainage, as their precise adjustment is a requirement for optimal patient care. This study focused on two adjustable shunt valves, the proGAV 2.0® and M. blue® (manufactured by Miethke, Potsdam, Germany). A comprehensive comparative analysis of PC CT and traditional X-ray techniques was conducted to explore this cutting-edge technology and it demonstrated that routine PC CT can efficiently assess shunt valves' adjustments. This technology shows promise in enhancing the accurate management of shunt valves used in settings where head scans are already frequently required, such as in the treatment of hydrocephalus.


Asunto(s)
Derivaciones del Líquido Cefalorraquídeo , Imagenología Tridimensional , Fantasmas de Imagen , Tomografía Computarizada por Rayos X , Tomografía Computarizada por Rayos X/métodos , Imagenología Tridimensional/métodos , Humanos , Derivaciones del Líquido Cefalorraquídeo/métodos , Fotones , Hidrocefalia/diagnóstico por imagen , Hidrocefalia/cirugía
6.
ACS Appl Mater Interfaces ; 16(17): 21486-21497, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38640485

RESUMEN

The combined effects of twisted intramolecular charge transfer (TICT) and aggregation-induced emission (AIE) phenomena have demonstrated a significant influence on excited-state chemistry. These combined TICT and AIE features have been extensively utilized to enhance photodynamic and photothermal therapy. Herein, we demonstrated the synergistic capabilities of TICT and AIE phenomena in the design of the photoremovable protecting group (PRPG), namely, NMe2-Napy-BF2. This innovative PRPG incorporates TICT and AIE characteristics, resulting in four remarkable properties: (i) red-shifted absorption wavelength, (ii) strong near-infrared (NIR) emission, (iii) viscosity-sensitive emission property, and (iv) accelerated photorelease rate. Inspired by these intriguing attributes, we developed a nanodrug delivery system (nano-DDS) using our PRPG for cancer treatment. In vitro studies showed that our nano-DDS manifested effective cellular internalization, specific staining of cancer cells, high-resolution confocal imaging of cancerous cells in the NIR region, and controlled release of the anticancer drug chlorambucil upon exposure to light, leading to cancer cell eradication. Most notably, our nano-DDS exhibited a substantially increased two-photon (TP) absorption cross section (435 GM), exhibiting its potential for in vivo applications. This development holds promise for significant advancements in cancer treatment strategies.


Asunto(s)
Naftiridinas , Fotones , Humanos , Naftiridinas/química , Naftiridinas/farmacología , Antineoplásicos/química , Antineoplásicos/farmacología , Clorambucilo/química , Clorambucilo/farmacología , Fotoquimioterapia , Línea Celular Tumoral , Supervivencia Celular/efectos de los fármacos , Neoplasias/tratamiento farmacológico , Neoplasias/patología , Nanopartículas/química
7.
Anal Chem ; 96(18): 7005-7013, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38657082

RESUMEN

Hydrogen sulfide (H2S), a critical gas signaling molecule, and N-acetyltransferase 2 (NAT2), a key enzyme in drug metabolism, are both known active biomarkers for liver function. However, the interactions and effects of H2S and NAT2 in living cells or lesion sites remain unknown due to the lack of imaging tools to achieve simultaneous detection of these two substances, making it challenging to implement real-time imaging and precise tracking. Herein, we report an activity-based two-photon fluorescent probe, TPSP-1, for the cascade detection of H2S and NAT2 in living liver cells. Continuous conversion from TPSP-1 to TPSP-3 was achieved in liver cells and tissues. Significantly, leveraging the outstanding optical properties of this two-photon fluorescent probe, TPSP-1, has been effectively used to identify pathological tissue samples directly from clinical liver cancer patients. This work provides us with this novel sensing and two-photon imaging probe, which can be used as a powerful tool to study the physiological functions of H2S and NAT2 and will help facilitate rapid and accurate diagnosis and therapeutic evaluation of hepatocellular carcinoma.


Asunto(s)
Arilamina N-Acetiltransferasa , Carcinoma Hepatocelular , Colorantes Fluorescentes , Sulfuro de Hidrógeno , Neoplasias Hepáticas , Fotones , Sulfuro de Hidrógeno/análisis , Sulfuro de Hidrógeno/metabolismo , Colorantes Fluorescentes/química , Colorantes Fluorescentes/síntesis química , Humanos , Arilamina N-Acetiltransferasa/metabolismo , Carcinoma Hepatocelular/metabolismo , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/metabolismo , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Animales , Ratones , Células Hep G2 , Imagen Óptica
8.
Nat Commun ; 15(1): 3192, 2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-38609354

RESUMEN

Neuronal ensembles are groups of neurons with correlated activity associated with sensory, motor, and behavioral functions. To explore how ensembles encode information, we investigated responses of visual cortical neurons in awake mice using volumetric two-photon calcium imaging during visual stimulation. We identified neuronal ensembles employing an unsupervised model-free algorithm and, besides neurons activated by the visual stimulus (termed "onsemble"), we also find neurons that are specifically inactivated (termed "offsemble"). Offsemble neurons showed faster calcium decay during stimuli, suggesting selective inhibition. In response to visual stimuli, each ensemble (onsemble+offsemble) exhibited small trial-to-trial variability, high orientation selectivity, and superior predictive accuracy for visual stimulus orientation, surpassing the sum of individual neuron activity. Thus, the combined selective activation and inactivation of cortical neurons enhances visual encoding as an emergent and distributed neural code.


Asunto(s)
Calcio , Neuronas , Animales , Ratones , Algoritmos , Inhibición Psicológica , Fotones
9.
Phys Med Biol ; 69(10)2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38565123

RESUMEN

Objective.To evaluate the reduction in energy dependence and aging effect of the lithium salt of pentacosa-10,-12-diynoic acid (LiPCDA) films with additives including aluminum oxide (Al2O3), propyl gallate (PG), and disodium ethylenediaminetetracetate (EDTA).Approach. LiPCDA films exhibited energy dependence on kilovoltage (kV) and megavoltage (MV) photon energies and experienced deterioration over time. Evaluations were conducted with added Al2O3and antioxidants to mitigate these issues, and films were produced with and without Al2O3to assess energy dependence. The films were irradiated at doses of 0, 3, 6, and 12 cGy at photon energies of 75 kV, 105 kV, 6 MV, 10 MV, and 15 MV. For the energy range of 75 kV to 15 MV, the mean and standard deviation (std) were calculated and compared for the values normalized to the net optical density (netOD) at 6 MV, corresponding to identical dose levels. To evaluate the aging effect, PG and disodium EDTA were incorporated into the films: sample C with 1% PG, sample D with 2% PG, sample E with 0.62% disodium EDTA added to sample D, and sample F with 1.23% disodium EDTA added to sample D.Main results. Films containing Al2O3demonstrated a maximum 15.8% increase in mean normalized values and a 15.1% reduction in std, reflecting a greater netOD reduction at kV than MV energies, which indicates less energy dependence in these films. When the OD of sample 1-4 depending on the addition of PG and disodium EDTA, was observed for 20 weeks, the transmission mode decreased by 8.7%, 8.3%, 29.3%, and 27.3%, respectively, while the reflection mode was 5.4%, 3.0%, 37.0%, and 34.5%, respectively.Significance. Al2O3effectively reduced the voltage and MV energy dependence. PG was more effective than disodium EDTA in preventing the deterioration of film performance owing to the aging effect.


Asunto(s)
Dosimetría por Película , Dosimetría por Película/instrumentación , Dosimetría por Película/métodos , Óxido de Aluminio/química , Ácido Edético/química , Galato de Propilo , Fotones
10.
Phys Med Biol ; 69(10)2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38588671

RESUMEN

Objective. A novel x-ray field produced by an ultrathin conical target is described in the literature. However, the optimal design for an associated collimator remains ambiguous. Current optimization methods using Monte Carlo calculations restrict the efficiency and robustness of the design process. A more generic optimization method that reduces parameter constraints while minimizing computational load is necessary. A numerical method for optimizing the longitudinal collimator hole geometry for a cylindrically-symmetrical x-ray tube is demonstrated and compared to Monte Carlo calculations.Approach. The x-ray phase space was modelled as a four-dimensional histogram differential in photon initial position, final position, and photon energy. The collimator was modeled as a stack of thin washers with varying inner radii. Simulated annealing was employed to optimize this set of inner radii according to various objective functions calculated on the photon flux at a specified plane.Main results. The analytical transport model used for optimization was validated against Monte Carlo calculations using Geant4 via its wrapper, TOPAS. Optimized collimators and the resulting photon flux profiles are presented for three focal spot sizes and five positions of the source. Optimizations were performed with multiple objective functions based on various weightings of precision, intensity, and field flatness metrics. Finally, a select set of these optimized collimators, plus a parallel-hole collimator for comparison, were modeled in TOPAS. The evolution of the radiation field profiles are presented for various positions of the source for each collimator.Significance. This novel optimization strategy proved consistent and robust across the range of x-ray tube settings regardless of the optimization starting point. Common collimator geometries were re-derived using this algorithm while simultaneously optimizing geometry-specific parameters. The advantages of this strategy over iterative Monte Carlo-based techniques, including computational efficiency, radiation source-specificity, and solution flexibility, make it a desirable optimization method for complex irradiation geometries.


Asunto(s)
Método de Montecarlo , Rayos X , Fotones , Modelos Teóricos
11.
PLoS One ; 19(4): e0301435, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38635642

RESUMEN

In radiotherapy, when photon energy exceeding 8 MV is utilized, photoneutrons can activate the components within the gantry of the linear accelerator (linac). At the end of the linac's lifecycle, radiation workers are tasked with its dismantling and disposal, potentially exposing them to unintentional radiation. This study aims to identify and measure the radioisotopes generated by this activation through spectroscopy, and to evaluate the effective dose rate. We selected nine medical linacs, considering various factors such as manufacturer (Siemens, Varian, and Elekta), model, energy, period of operation, and workload. We identified the radionuclides in the linac head by employing an in situ high-purity germanium (HPGe) detector. Spectroscopy and dose-rate measurements were conducted post-shutdown. We also measured the dose rates at the beam-exit window following irradiation with 10 MV and 15 MV photon beams. As a result of the spectroscopy, we identified approximately 20 nuclides including those with half-lives of 100 days or longer, such as 54Mn, 60Co, 65Zn, 122Sb, and 198Au. The dose rate measurements after 10 MV irradiation decreased to the background level in 10 min. By contrast, on 15 MV irradiation, the dose rate was 628 nSv/h after 10 min and decreased to 268 nSv/h after 1.5 hours. It was confirmed that the difference in the level of radiation and the type of nuclide depends on the period of use, energy, and workload. However, the type of nuclide does not differ significantly between the linacs. It is necessary to propose appropriate guidelines for the safety of workers, and disposal/move-install should be planned while taking into consideration the equipment's energy usage rate.


Asunto(s)
Manganeso , Radioisótopos , Humanos , Dosificación Radioterapéutica , Aceleradores de Partículas , Fotones , Análisis Espectral
12.
Methods Mol Biol ; 2794: 33-43, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38630218

RESUMEN

Two-photon FRET (Förster resonance energy transfer) and FLIM (fluorescence lifetime imaging microscopy) enable the detection of FRET changes of fluorescence reporters in deep brain tissues, which provide a valuable approach for monitoring target molecular dynamics and functions. Here, we describe two-photon FRET and FLIM imaging techniques that allow us to visualize endogenous and optogenetically induced cAMP dynamics in living neurons with genetically engineered FRET-based cAMP reporters.


Asunto(s)
Transferencia Resonante de Energía de Fluorescencia , Ingeniería Genética , Microscopía Fluorescente , Neuronas , Fotones
13.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(2): 156-159, 2024 Mar 30.
Artículo en Chino | MEDLINE | ID: mdl-38605614

RESUMEN

Objective: The distribution of the photon energy spectrum in isocenter plane of the medical linear accelerator and the influence of secondary collimator on the photon energy spectrum are studied. Methods Use the BEAMnrc program to simulate the transmission of the 6 MeV electrons and photons in 5 cm×5 cm,10 cm×10 cm,15 cm×15 cm and 20 cm×20 cm fields in treatment head of the medical linear accelerator, where a phase space file was set up at the isocenter plane to record the particle information passing through this plane. The BEAMdp program is used to analyze the phase space file, in order to obtain the distribution of the photon energy spectrum in isocenter plane and the influence of secondary collimator on the photon energy spectrum. Results: By analyzing the photon energy spectrum of a medical linear accelerator with a nominal energy of 6 MV, it is found that the secondary collimator has little effect on the photon energy spectrum; different fields have different photon energy spectrum distributions; the photon energy spectrum in different central regions of the same field have the same normalized distribution. Conclusion: In the dose calculation of radiation therapy, the influence of photon energy spectrum should be carefully considered.


Asunto(s)
Fotones , Planificación de la Radioterapia Asistida por Computador , Método de Montecarlo , Fotones/uso terapéutico , Aceleradores de Partículas , Fantasmas de Imagen , Dosificación Radioterapéutica
14.
Anal Chem ; 96(17): 6700-6706, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38621112

RESUMEN

Photonic crystals with specific wavelengths can realize surface-enhanced excitation and emission intensities of fluorophores and enhance the fluorescence signals of fluorescent molecules. Herein, stretchable photonic crystals with good mechanochromic properties provide continuously adjustable forbidden wavelengths by stretching to change the lattice spacing, with reflectance peaks blue-shifted up to 110 nm to match indicators of different wavelengths and produce differentiated optical enhancement effects. Glycoproteins are significantly identified as clinical markers. However, the wide participation of glycoproteins in various life processes poses enormous complexity and critical challenges for rapid, facile, high-throughput, and accurate clinical analysis or health assessment. In this work, we proposed a stretchable photonic crystal-assisted glycoprotein identification approach for early ovarian cancer diagnosis. Stretchable photonic crystals can provide rich optical information to efficiently identify glycoproteins in complex matrices. A double-indicator fluorescence sensor was designed to respond to the protein trunk and oligosaccharide segment of glycoproteins separately for improved recognition accuracy. Seven typical glycoproteins could be discriminated from proteins, saccharides, or mixture interferents. Clinical ovarian cancer samples for early, intermediate, and advanced ovarian cancer and healthy subjects were verified with 100% accuracy. This strategy of stretchable photonic crystal-assisted glycoprotein identification provides an effective method for accurate, rapid ovarian cancer diagnosis and timely clinical treatment.


Asunto(s)
Glicoproteínas , Neoplasias Ováricas , Femenino , Neoplasias Ováricas/diagnóstico , Humanos , Glicoproteínas/análisis , Fotones , Colorantes Fluorescentes/química , Biomarcadores de Tumor/análisis , Cristalización
15.
Anal Chem ; 96(17): 6674-6682, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38642044

RESUMEN

Photodynamic therapy (PDT) is a significant noninvasive therapeutic modality, but it is often limited in its application due to the restricted tissue penetration depth caused by the wavelength limitations of the light source. Two-photon (TP) fluorescence techniques are capable of having an excitation wavelength in the NIR region by absorbing two NIR photons simultaneously, which offers the potential to achieve higher spatial resolution for deep tissue imaging. Thus, the adoption of TP fluorescence techniques affords several discernible benefits for photodynamic therapy. Organic TP dyes possess a high fluorescence quantum yield. However, the biocompatibility of organic TP dyes is poor, and the method of coating organic TP dyes with silica can effectively overcome the limitations. Herein, based on the TP silica nanoparticles, a functionalized intelligent biogenic missile TP-SiNPs-G4(TMPyP4)-dsDNA(DOX)-Aptamer (TGTDDA) was developed for effective TP bioimaging and synergistic targeted photodynamic therapy and chemotherapy in tumors. First, the Sgc8 aptamer was used to target the PTK7 receptor on the surface of tumor cells. Under two-photon light irradiation, the intelligent biogenic missile can be activated for TP fluorescence imaging to identify tumor cells and the photosensitizer assembled on the nanoparticle surface can be activated for photodynamic therapy. Additionally, this intelligent biogenic missile enables the controlled release of doxorubicin (DOX). The innovative strategy substantially enhances the targeted therapeutic effectiveness of cancer cells. The intelligent biogenic missile provides an effective method for the early detection and treatment of tumors, which has a good application prospect in the real-time high-sensitivity diagnosis and treatment of tumors.


Asunto(s)
Imagen Óptica , Fotoquimioterapia , Fotones , Fármacos Fotosensibilizantes , Humanos , Animales , Fármacos Fotosensibilizantes/química , Fármacos Fotosensibilizantes/farmacología , Fármacos Fotosensibilizantes/uso terapéutico , Ratones , Nanopartículas/química , Doxorrubicina/química , Doxorrubicina/farmacología , Doxorrubicina/uso terapéutico , Dióxido de Silicio/química , Aptámeros de Nucleótidos/química , Colorantes Fluorescentes/química , Neoplasias/tratamiento farmacológico , Neoplasias/diagnóstico por imagen , Antineoplásicos/química , Antineoplásicos/farmacología , Ratones Desnudos , Línea Celular Tumoral , Ratones Endogámicos BALB C
16.
Acta Med Okayama ; 78(2): 135-142, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38688831

RESUMEN

This study aimed to evaluate the potential reduction in contrast medium utilization using photon-counting detector computed tomography (PCD-CT). One PCD-CT scan (CT1) and three conventional (non-PCD-CT) CT scans (CT2-CT4) were performed using a multi-energy CT phantom that contained eight rods with different iodine concentrations (0.2, 0.5, 1, 2, 5, 10, 15, and 20 mg/ml). The CT values of the seven groups (CT1 for 40, 50, 60, and 70 keV; and CT2-4) were measured. Noise and contrast-to-noise ratio (CNR) were assessed for the eight rods at various iodine concentrations. CT2 and CT1 (40 keV) respectively required 20 mg/ml and 5 mg/ml of iodine, indicating that a comparable contrast effect could be obtained with approximately one-fourth of the contrast medium amount. The standard deviation values increased at lower energy levels irrespective of the iodine concentration. The CNR exhibited a decreasing trend with lower iodine concentrations, while it remained relatively stable across all iodine levels (40-70 keV). This study demonstrated that virtual monochromatic 40 keV images offer a similar contrast effect with a reduced contrast medium amount when compared to conventional CT systems at 120 kV.


Asunto(s)
Medios de Contraste , Fantasmas de Imagen , Fotones , Tomografía Computarizada por Rayos X , Medios de Contraste/química , Tomografía Computarizada por Rayos X/métodos , Yodo , Humanos
17.
Talanta ; 274: 126018, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38593645

RESUMEN

Colorectum cancer has become one of the most fatal cancer diseases, in which NAD(P)H: quinone oxidoreductase 1 (NQO1) plays a role in intracellular free radical reduction and detoxification and has been linked to colorectum cancer and chemotherapy resistance. Therefore, rational design of optical probe for NQO1 detection is urgent for the early diagnosis of colorectum cancer. Herein, we have developed a novel two-photon fluorescent probe, WHFD, which is capable of selectively detecting of intracellular NQO1 with two-photon (TP) absorption (800 nm) and near-infrared emission (620 nm). Combination with a substantial Stokes shift (175 nm) and biocompatibility, we have assessed its suitability for in vivo imaging of endogenous NQO1 activities from HepG2 tumor-bearing live animals with high tissue penetration up to 300 µm. Particularly, we for the first time used the probe to image NQO1 activities from human colorectum cancer samples by using TP microscopy, and proving our probe possesses reliable diagnostic performance to directly in situ imaging of cancer biomarker and can clearly distinguish the boundary between human colorectum cancer tissue and their surrounding normal tissue, which shows great potential for the intraoperative navigation.


Asunto(s)
Neoplasias Colorrectales , Colorantes Fluorescentes , NAD(P)H Deshidrogenasa (Quinona) , Fotones , NAD(P)H Deshidrogenasa (Quinona)/metabolismo , NAD(P)H Deshidrogenasa (Quinona)/análisis , Humanos , Colorantes Fluorescentes/química , Colorantes Fluorescentes/síntesis química , Neoplasias Colorrectales/diagnóstico por imagen , Neoplasias Colorrectales/patología , Animales , Células Hep G2 , Imagen Óptica , Rayos Infrarrojos , Ratones , Ratones Desnudos
18.
Talanta ; 274: 126120, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38640603

RESUMEN

Peroxynitrite (ONOO-) and cell plasma membrane (CPM) are two key factors in cell pyroptosis during the progression of abdominal aortic aneurysm (AAA). However, their combined temporal and spatial roles in initiating AAA pathogenesis remain unclear. Herein, we developed a two-photon fluorescence probe, BH-Vis, enabling real-time dynamic detection of CPM and ONOO- changes, and revealing their interplay in AAA. BH-Vis precisely targets CPM with reduced red fluorescence intensity correlating with diminished CPM tension. Concurrently, a blue shift of the fluorescence signal of BH-Vis occurs in response to ONOO- offering a reliable ratiometric detection mode with enhanced accuracy by minimizing external testing variables. More importantly, two photon confocal imaging with palmitic acid (PA) and ganglioside (GM1) manipulation, which modulating cell pyroptosis, showcases reliable fluorescence fluctuations. This groundbreaking application of BH-Vis in a mouse AAA model demonstrates its significant potential for accurately identifying cell pyroptosis levels during AAA development.


Asunto(s)
Aneurisma de la Aorta Abdominal , Membrana Celular , Imagen Óptica , Ácido Peroxinitroso , Aneurisma de la Aorta Abdominal/metabolismo , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/patología , Ácido Peroxinitroso/metabolismo , Animales , Ratones , Membrana Celular/metabolismo , Membrana Celular/química , Humanos , Colorantes Fluorescentes/química , Piroptosis/efectos de los fármacos , Ratones Endogámicos C57BL , Masculino , Fotones
19.
ACS Sens ; 9(4): 1857-1865, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38597428

RESUMEN

Resonant photonic refractive index sensors have made major advances based on their high sensitivity and contact-less readout capability, which is advantageous in many areas of science and technology. A major issue for the technological implementation of such sensors is their response to external influences, such as vibrations and temperature variations; the more sensitive a sensor, the more susceptible it also becomes to external influences. Here, we introduce a novel bowtie-shaped sensor that is highly responsive to refractive index variations while compensating for temperature changes and mechanical (linear and angular) vibrations. We exemplify its capability by demonstrating the detection of salinity to a precision of 0.1%, corresponding to 2.3 × 10-4 refractive index units in the presence of temperature fluctuations and mechanical vibrations. As a second exemplar, we detected bacteria growth in a pilot industrial environment. Our results demonstrate that it is possible to translate high sensitivity resonant photonic refractive index sensors into real-world environments.


Asunto(s)
Fotones , Refractometría , Temperatura , Vibración , Salinidad
20.
Spectrochim Acta A Mol Biomol Spectrosc ; 316: 124311, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-38663131

RESUMEN

In this study, a set of potential quasi-intrinsic photosensitizers for two-photon photodynamic therapy (PDT) are proposed based on the unnatural 2-amino-8-(1'-ß-ᴅ-2'-deoxyribofuranosyl)-imidazo[1,2-ɑ]-1,3,5-triazin-4(8H)-one (P), which is paired with the 6-amino-5-nitro-3-(1'-ß-ᴅ-2'-deoxyribofuranosyl)-2(1H)-pyridone (Z) and can specifically recognize breast and liver cancer cells. Herein, the effects of sulfur substitution and electron-donating/electron-withdrawing groups on the photophysical properties in aqueous solution are systematically investigated. The one- and two-photon absorption spectra evidence that the modifications could result in red-shifted absorption wavelength and large two-photon absorption cross-section, which contributes to selective excitation and provides effective PDT for deep-seated tissues. To ensure the efficient triplet state population, the singlet-triplet energy gaps and spin-orbit coupling constants were examined, which is responsible for a rapid intersystem crossing rate. Furthermore, these thiobase derivatives are characterized by the long-lived T1 state and the large energy gap for radiationless transition to ensure the generation of cytotoxic singlet oxygen.


Asunto(s)
Fotoquimioterapia , Fotones , Fármacos Fotosensibilizantes , Fármacos Fotosensibilizantes/farmacología , Fármacos Fotosensibilizantes/química , Humanos , Oxígeno Singlete/metabolismo , Oxígeno Singlete/química , Línea Celular Tumoral
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...