Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.505
Filtrar
1.
Neurosurg Focus ; 56(5): E9, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38691864

RESUMEN

OBJECTIVE: Chordomas are rare tumors of the skull base and spine believed to arise from the vestiges of the embryonic notochord. These tumors are locally aggressive and frequently recur following resection and adjuvant radiotherapy. Proton therapy has been introduced as a tissue-sparing option because of the higher level of precision that proton-beam techniques offer compared with traditional photon radiotherapy. This study aimed to compare recurrence in patients with chordomas receiving proton versus photon radiotherapy following resection by applying tree-based machine learning models. METHODS: The clinical records of all patients treated with resection followed by adjuvant proton or photon radiotherapy for chordoma at Mayo Clinic were reviewed. Patient demographics, type of surgery and radiotherapy, tumor recurrence, and other variables were extracted. Decision tree classifiers were trained and tested to predict long-term recurrence based on unseen data using an 80/20 split. RESULTS: Fifty-three patients with a mean ± SD age of 55.2 ± 13.4 years receiving surgery and adjuvant proton or photon therapy to treat chordoma were identified; most patients were male. Gross-total resection was achieved in 54.7% of cases. Proton therapy was the most common adjuvant radiotherapy (84.9%), followed by conventional or external-beam radiation therapy (9.4%) and stereotactic radiosurgery (5.7%). Patients receiving proton therapy exhibited a 40% likelihood of having recurrence, significantly lower than the 88% likelihood observed in those treated with nonproton therapy. This was confirmed on logistic regression analysis adjusted for extent of tumor resection and tumor location, which revealed that proton adjuvant radiotherapy was associated with a decreased risk of recurrence (OR 0.1, 95% CI 0.01-0.71; p = 0.047) compared with photon therapy. The decision tree algorithm predicted recurrence with an accuracy of 90% (95% CI 55.5%-99.8%), with the lowest risk of recurrence observed in patients receiving gross-total resection with adjuvant proton therapy (23%). CONCLUSIONS: Following resection, adjuvant proton therapy was associated with a lower risk of chordoma recurrence compared with photon therapy. The described machine learning models were able to predict tumor progression based on the extent of tumor resection and adjuvant radiotherapy modality used.


Asunto(s)
Cordoma , Recurrencia Local de Neoplasia , Fotones , Terapia de Protones , Neoplasias de la Columna Vertebral , Humanos , Cordoma/radioterapia , Cordoma/cirugía , Masculino , Femenino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/radioterapia , Terapia de Protones/métodos , Radioterapia Adyuvante/métodos , Adulto , Anciano , Neoplasias de la Columna Vertebral/radioterapia , Neoplasias de la Columna Vertebral/cirugía , Fotones/uso terapéutico , Estudios Retrospectivos , Resultado del Tratamiento
2.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(2): 156-159, 2024 Mar 30.
Artículo en Chino | MEDLINE | ID: mdl-38605614

RESUMEN

Objective: The distribution of the photon energy spectrum in isocenter plane of the medical linear accelerator and the influence of secondary collimator on the photon energy spectrum are studied. Methods Use the BEAMnrc program to simulate the transmission of the 6 MeV electrons and photons in 5 cm×5 cm,10 cm×10 cm,15 cm×15 cm and 20 cm×20 cm fields in treatment head of the medical linear accelerator, where a phase space file was set up at the isocenter plane to record the particle information passing through this plane. The BEAMdp program is used to analyze the phase space file, in order to obtain the distribution of the photon energy spectrum in isocenter plane and the influence of secondary collimator on the photon energy spectrum. Results: By analyzing the photon energy spectrum of a medical linear accelerator with a nominal energy of 6 MV, it is found that the secondary collimator has little effect on the photon energy spectrum; different fields have different photon energy spectrum distributions; the photon energy spectrum in different central regions of the same field have the same normalized distribution. Conclusion: In the dose calculation of radiation therapy, the influence of photon energy spectrum should be carefully considered.


Asunto(s)
Fotones , Planificación de la Radioterapia Asistida por Computador , Método de Montecarlo , Fotones/uso terapéutico , Aceleradores de Partículas , Fantasmas de Imagen , Dosificación Radioterapéutica
3.
Phys Med Biol ; 69(11)2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38657630

RESUMEN

Objective. We provide optimal particle split numbers for speeding up TOPAS Monte Carlo simulations of linear accelerator (linac) treatment heads while maintaining accuracy. In addition, we provide a new TOPAS physics module for simulating photoneutron production and transport.Approach.TOPAS simulation of a Siemens Oncor linac was used to determine the optimal number of splits for directional bremsstrahlung splitting as a function of the field size for 6 MV and 18 MV x-ray beams. The linac simulation was validated against published data of lateral dose profiles and percentage depth-dose curves (PDD) for the largest square field (40 cm side). In separate simulations, neutron particle split and the custom TOPAS physics module was used to generate and transport photoneutrons, called 'TsPhotoNeutron'. Verification of accuracy was performed by comparing simulations with published measurements of: (1) neutron yields as a function of beam energy for thick targets of Al, Cu, Ta, W, Pb and concrete; and (2) photoneutron energy spectrum at 40 cm laterally from the isocenter of the Oncor linac from an 18 MV beam with closed jaws and MLC.Main results.The optimal number of splits obtained for directional bremsstrahlung splitting enhanced the computational efficiency by two orders of magnitude. The efficiency decreased with increasing beam energy and field size. Calculated lateral profiles in the central region agreed within 1 mm/2% from measured data, PDD curves within 1 mm/1%. For the TOPAS physics module, at a split number of 146, the efficiency of computing photoneutron yields was enhanced by a factor of 27.6, whereas it improved the accuracy over existing Geant4 physics modules.Significance.This work provides simulation parameters and a new TOPAS physics module to improve the efficiency and accuracy of TOPAS simulations that involve photonuclear processes occurring in high-Zmaterials found in linac components, patient devices, and treatment rooms, as well as to explore new therapeutic modalities such as very-high energy electron therapy.


Asunto(s)
Método de Montecarlo , Neutrones , Aceleradores de Partículas , Fotones , Fotones/uso terapéutico , Factores de Tiempo , Dosificación Radioterapéutica , Reproducibilidad de los Resultados , Simulación por Computador , Humanos , Radioterapia/métodos
4.
Radiother Oncol ; 195: 110264, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38561122

RESUMEN

BACKGROUND: High-level evidence on hypofractionated proton therapy (PT) for localized and locally advanced prostate cancer (PCa) patients is currently missing. The aim of this study is to provide a systematic literature review to compare the toxicity and effectiveness of curative radiotherapy with photon therapy (XRT) or PT in PCa. METHODS: PubMed, Embase, and the Cochrane Library databases were systematically searched up to April 2022. Men with a diagnosis of PCa who underwent curative hypofractionated RT treatment (PT or XRT) were included. Risk of grade (G) ≥ 2 acute and late genitourinary (GU) OR gastrointestinal (GI) toxicity were the primary outcomes of interest. Secondary outcomes were five-year biochemical relapse-free survival (b-RFS), clinical relapse-free, distant metastasis-free, and prostate cancer-specific survival. Heterogeneity between study-specific estimates was assessed using Chi-square statistics and measured with the I2 index (heterogeneity measure across studies). RESULTS: A total of 230 studies matched inclusion criteria and, due to overlapped populations, 160 were included in the present analysis. Significant lower rates of G ≥ 2 acute GI incidence (2 % vs 7 %) and improved 5-year biochemical relapse-free survival (95 % vs 91 %) were observed in the PT arm compared to XRT. PT benefits in 5-year biochemical relapse-free survival were maintained for the moderate hypofractionated arm (p-value 0.0122) and among patients in intermediate and low-risk classes (p-values < 0.0001 and 0.0368, respectively). No statistically relevant differences were found for the other considered outcomes. CONCLUSION: The present study supports that PT is safe and effective for localized PCa treatment, however, more data from RCTs are needed to draw solid evidence in this setting and further effort must be made to identify the patient subgroups that could benefit the most from PT.


Asunto(s)
Fotones , Neoplasias de la Próstata , Terapia de Protones , Hipofraccionamiento de la Dosis de Radiación , Humanos , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/mortalidad , Masculino , Terapia de Protones/métodos , Terapia de Protones/efectos adversos , Fotones/uso terapéutico
5.
Phys Med Biol ; 69(9)2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38537301

RESUMEN

Thein vivoevolution of radiotherapy necessitates innovative platforms for preclinical investigation, bridging the gap between bench research and clinical applications. Understanding the nuances of radiation response, specifically tailored to proton and photon therapies, is critical for optimizing treatment outcomes. Within this context, preclinicalin vivoexperimental setups incorporating image guidance for both photon and proton therapies are pivotal, enabling the translation of findings from small animal models to clinical settings. TheSAPPHIREproject represents a milestone in this pursuit, presenting the installation of the small animal radiation therapy integrated beamline (SmART+ IB, Precision X-Ray Inc., Madison, Connecticut, USA) designed for preclinical image-guided proton and photon therapy experiments at University Proton Therapy Dresden. Through Monte Carlo simulations, low-dose on-site cone beam computed tomography imaging and quality assurance alignment protocols, the project ensures the safe and precise application of radiation, crucial for replicating clinical scenarios in small animal models. The creation of Hounsfield lookup tables and comprehensive proton and photon beam characterizations within this system enable accurate dose calculations, allowing for targeted and controlled comparison experiments. By integrating these capabilities,SAPPHIREbridges preclinical investigations and potential clinical applications, offering a platform for translational radiobiology research and cancer therapy advancements.


Asunto(s)
Fotones , Terapia de Protones , Radioterapia Guiada por Imagen , Fotones/uso terapéutico , Animales , Radioterapia Guiada por Imagen/métodos , Terapia de Protones/métodos , Método de Montecarlo , Protones , Ratones
6.
Comput Biol Med ; 173: 108334, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38520919

RESUMEN

Hypoxia contributes significantly to resistance in radiotherapy. Our research rigorously examines the influence of microvascular morphology on radiotherapy outcome, specifically focusing on how microvasculature shapes hypoxia within the microenvironment and affects resistance to a standard treatment regimen (30×2GyRBE). Our computational modeling extends to the effects of different radiation sources. For photons and protons, our analysis establishes a clear correlation between hypoxic volume distribution and treatment effectiveness, with vascular density and regularity playing a crucial role in treatment success. On the contrary, carbon ions exhibit distinct effectiveness, even in areas of intense hypoxia and poor vascularization. This finding points to the potential of carbon-based hadron therapy in overcoming hypoxia-induced resistance to RT. Considering that the spatial scale analyzed in this study is closely aligned with that of imaging data voxels, we also address the implications of these findings in a clinical context envisioning the possibility of detecting subvoxel hypoxia.


Asunto(s)
Hipoxia , Fotones , Humanos , Fotones/uso terapéutico , Carbono
7.
Semin Radiat Oncol ; 34(2): 218-228, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38508786

RESUMEN

FLASH is an emerging treatment paradigm in radiotherapy (RT) that utilizes ultra-high dose rates (UHDR; >40 Gy)/s) of radiation delivery. Developing advances in technology support the delivery of UHDR using electron and proton systems, as well as some ion beam units (eg, carbon ions), while methods to achieve UHDR with photons are under investigation. The major advantage of FLASH RT is its ability to increase the therapeutic index for RT by shifting the dose response curve for normal tissue toxicity to higher doses. Numerous preclinical studies have been conducted to date on FLASH RT for murine sarcomas, alongside the investigation of its effects on relevant normal tissues of skin, muscle, and bone. The tumor control achieved by FLASH RT of sarcoma models is indistinguishable from that attained by treatment with standard RT to the same total dose. FLASH's high dose rates are able to mitigate the severity or incidence of RT side effects on normal tissues as evaluated by endpoints ranging from functional sparing to histological damage. Large animal studies and clinical trials of canine patients show evidence of skin sparing by FLASH vs. standard RT, but also caution against delivery of high single doses with FLASH that exceed those safely applied with standard RT. Also, a human clinical trial has shown that FLASH RT can be delivered safely to bone metastasis. Thus, data to date support continued investigations of clinical translation of FLASH RT for the treatment of patients with sarcoma. Toward this purpose, hypofractionated irradiation schemes are being investigated for FLASH effects on sarcoma and relevant normal tissues.


Asunto(s)
Traumatismos por Radiación , Oncología por Radiación , Sarcoma , Humanos , Animales , Perros , Ratones , Sarcoma/radioterapia , Fotones/uso terapéutico , Hipofraccionamiento de la Dosis de Radiación , Dosificación Radioterapéutica
8.
Biomed Phys Eng Express ; 10(2)2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38306972

RESUMEN

Objectives.In an addendum to AAPM TG-51 protocol, McEwenet al, (DOI:10.1118/1.4866223) introduced a new factorPrpto account for the radial dose distribution of the photon beam over the detector volume mainly in flattening filter free (FFF) beams.Prpand its extension to non-FFF beam reference dosimetry is investigated to see its impact in a clinical situation.Approches.ThePrpwas measured using simplified version of Sudhyadhomet al(DOI:10.1118/1.4941691) for Elekta and Varian FFF beams with two commonly used calibration detectors; PTW-30013 and Exradin-A12 ion chambers after acquiring high resolution profiles in detectors cardinal coordinates. For radial dose correction factor, the ion chambers were placed in a small water phantom and the central axis position was set to center of the sensitive volume on the treatment table and was studied by rotating the table by 15-degree interval from -90 to +90 degrees with respect to the initial (zero) position.Main results.The magnitude ofPrpvaries very little with machine, detector and beam energies to a value of 1.003 ± 0.0005 and 1.005 ± 0.0005 for 6FFF and 10FFF, respectively. The radial anisotropy for the Elekta machine with Exradin-A12 and PTW-30013 detector the magnitudes are in the range of (0.9995±0.0011 to 1.0015±0.0010) and (0.9998±0.0007 to 1.0015±0.0010), respectively. Similarly, for the Varian machine with Exradin-A12 and PTW-30013 ion chambers, the magnitudes are in the range of (1.0004±0.0010 to 1.0018±0.0018) and (1.0006±0.0009 to 1.0027±0.0007), respectively.Significance.ThePrpis ≤ 0.3% and 0.5% for 6FFF and 10FFF, respectively. The radial dose correction factor in regular beams also does not impact the dosimetry where the maximum magnitude is ±0.2% which is within experimental uncertainty.


Asunto(s)
Fotones , Radiometría , Fotones/uso terapéutico , Radiometría/métodos , Fantasmas de Imagen , Calibración , Incertidumbre , Carmustina
9.
Radiother Oncol ; 194: 110157, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38367939

RESUMEN

BACKGROUND AND PURPOSE: Ependymoma is the third most frequent childhood braintumor. Standard treatment is surgery followed by radiation therapy including proton therapy (PBT). Retrospective studies have reported higher rates of brainstem injury after PBT than after photon therapy (XRT). We report a national multicenter study of the incidence of brainstem injury after XRT versus PBT, and their correlations with dosimetric data. MATERIAL AND METHODS: We included all patients aged < 25 years who were treated with PBT or XRT for intracranial ependymoma at five French pediatric oncology reference centers between 2007 and 2020. We reviewed pre-irradiation MRI, follow-up MRIs over the 12 months post-treatment and clinical data. RESULTS: Of the 83 patients, 42 were treated with PBT, 37 with XRT, and 4 with both (median dose: 59.4 Gy, range: 53­60). No new or progressive symptomatic brainstem injury was found. Four patients presented asymptomatic radiographic changes (punctiform brainstem enhancement and FLAIR hypersignal), with median onset at 3.5 months (range: 3.0­9.4) after radiation therapy, and median offset at 7.6 months (range: 3.7­7.9). Two had been treated with PBT, one with XRT, and one with mixed XRT-PBT. Prescribed doses were 59.4, 55.8, 59.4 and 54 Gy. CONCLUSION: Asymptomatic radiographic changes occurred in 4.8% of patients with ependymoma in a large national series. There was no correlation with dose or technique. No symptomatic brainstem injury was identified.


Asunto(s)
Neoplasias Encefálicas , Tronco Encefálico , Ependimoma , Terapia de Protones , Humanos , Ependimoma/radioterapia , Ependimoma/diagnóstico por imagen , Terapia de Protones/efectos adversos , Estudios Retrospectivos , Femenino , Masculino , Niño , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/diagnóstico por imagen , Adolescente , Preescolar , Tronco Encefálico/efectos de la radiación , Tronco Encefálico/diagnóstico por imagen , Adulto Joven , Francia , Fotones/uso terapéutico , Fotones/efectos adversos , Traumatismos por Radiación/etiología , Imagen por Resonancia Magnética , Lactante , Dosificación Radioterapéutica
11.
Phys Med Biol ; 69(5)2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38385258

RESUMEN

Objective. Prompt gamma photon, prompt x-ray, and induced positron imaging are possible methods for observing a proton beam's shape from outside the subject. However, since these three types of images have not been measured simultaneously nor compared using the same subject, their advantages and disadvantages remain unknown for imaging beam shapes in therapy. To clarify these points, we developed a triple-imaging-modality system to simultaneously measure prompt gamma photons, prompt x-rays, and induced positrons during proton beam irradiation to a phantom.Approach. The developed triple-imaging-modality system consists of a gamma camera, an x-ray camera, and a dual-head positron emission tomography (PET) system. During 80 MeV proton beam irradiation to a polymethyl methacrylate (PMMA) phantom, imaging of prompt gamma photons was conducted by the developed gamma camera from one side of the phantom. Imaging of prompt x-rays was conducted by the developed x-ray camera from the other side. Induced positrons were measured by the developed dual-head PET system set on the upper and lower sides of the phantom.Main results. With the proposed triple-imaging-modality system, we could simultaneously image the prompt gamma photons and prompt x-rays during proton beam irradiation. Induced positron distributions could be measured after the irradiation by the PET system and the gamma camera. Among these imaging modalities, image quality was the best for the induced positrons measured by PET. The estimated ranges were actually similar to those imaged with prompt gamma photons, prompt x-rays and induced positrons measured by PET.Significance. The developed triple-imaging-modality system made possible to simultaneously measure the three different beam images. The system will contribute to increasing the data available for imaging in therapy and will contribute to better estimating the shapes or ranges of proton beam.


Asunto(s)
Terapia de Protones , Protones , Rayos X , Electrones , Terapia de Protones/métodos , Tomografía Computarizada por Rayos X , Fotones/uso terapéutico , Rayos gamma , Fantasmas de Imagen , Método de Montecarlo
12.
Sci Rep ; 14(1): 4510, 2024 02 24.
Artículo en Inglés | MEDLINE | ID: mdl-38402259

RESUMEN

Grid therapy recently has been picking momentum due to favorable outcomes in bulky tumors. This is being termed as Spatially Fractionated Radiation Therapy (SFRT) and lattice therapy. SFRT can be performed with specially designed blocks made with brass or cerrobend with repeated holes or using multi-leaf collimators where dosimetry is uncertain. The dosimetric challenge in grid therapy is the mystery behind the lower percentage depth dose (PDD) in grid fields. The knowledge about the beam quality, indexed by TPR20/10 (Tissue Phantom Ratio), is also necessary for absolute dosimetry of grid fields. Since the grid may change the quality of the primary photons, a new [Formula: see text] should be evaluated for absolute dosimetry of grid fields. A Monte Carlo (MC) approach is provided to resolving the dosimetric issues. Using 6 MV beam from a linear accelerator, MC simulation was performed using MCNPX code. Additionally, a commercial grid therapy device was used to simulate the grid fields. Beam parameters were validated with MC model for output factor, depth of maximum dose, PDDs, dose profiles, and TPR20/10. The electron and photon spectra were also compared between open and grid fields. The dmax is the same for open and grid fields. The PDD with grid is lower (~ 10%) than the open field. The difference in TPR20/10 of open and grid fields is observable (~ 5%). Accordingly, TPR20/10 is still a good index for the beam quality in grid fields and consequently choose the correct [Formula: see text] in measurements. The output factors for grid fields are 0.2 lower compared to open fields. The lower depth dose with grid therapy is due to lower depth fluence with scatter radiation but it does not impact the dosimetry as the calibration parameters are insensitive to the effective beam energies. Thus, standard dosimetry in open beam based on international protocol could be used.


Asunto(s)
Fotones , Radiometría , Radiometría/métodos , Fotones/uso terapéutico , Electrones , Fantasmas de Imagen , Método de Montecarlo , Aceleradores de Partículas , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
13.
Phys Med Biol ; 69(3)2024 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-38198720

RESUMEN

Objective. A discrete ordinates Boltzmann solver has recently been developed for use as a fast and accurate dose engine for calculation of photon and proton beams. The purpose of this study is to apply the algorithm to the inverse planning process for photons and protons and to evaluate the impact that this has on the quality of the final solution.Approach.The method was implemented into an iterative least-squares inverse planning optimiser, with the Boltzmann solver used every 20 iterations over the total of 100 iterations. Elemental dose distributions for the intensity modulation and the dose changes at the intermediate iterations were calculated by a convolution algorithm for photons and a simple analytical model for protons. The method was evaluated for 12 patients in the heterogeneous tissue environment encountered in radiotherapy of lung tumours. Photon arc and proton arc treatments were considered in this study. The results were compared with those for use of the Boltzmann solver solely at the end of inverse planning or not at all.Main results.Application of the Boltzmann solver at the end of inverse planning shows the dose heterogeneity in the planning target volume to be greater than calculated by convolution and empirical methods, with the median root-mean-square dose deviation increasing from 3.7 to 5.3 for photons and from 1.9 to 3.4 for proton arcs. Use of discrete ordinates throughout inverse planning enables homogeneity of target coverage to be maintained throughout, the median root-mean-square dose deviation being 3.6 for photons and 2.3 for protons. Dose to critical structures is similar with discrete ordinates and conventional methods. Time for inverse planning with discrete ordinates takes around 1-2 h using a contemporary computing environment.Significance.By incorporating the Boltzmann solver into an iterative least squares inverse planning optimiser, accurate dose calculation in a heterogeneous medium is obtained throughout inverse planning, with the result that the final dose distribution is of the highest quality.


Asunto(s)
Terapia de Protones , Radioterapia de Intensidad Modulada , Humanos , Protones , Fotones/uso terapéutico , Pulmón , Planificación de la Radioterapia Asistida por Computador/métodos , Algoritmos , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos
14.
Phys Eng Sci Med ; 47(1): 371-379, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37943444

RESUMEN

The TRS-483 Code of Practice (CoP) provides generic relative output correction factors, [Formula: see text], for a range of detectors and beam energies as used in small field dosimetry. In this work, the convergence of the relative output factors (ROFs) for 6 MV X-ray beams with and without flattening filters was investigated under different combinations of beam collimation and published detector correction factors. The SFD, PFD and CC04 (IBA) were used to measure ROFs of a TrueBeam STx linear accelerator with small fields collimated by the high-definition MLC, which has 2.5 and 5.0 mm projected leaves. Two configurations were used for the collimators: (1) fixed jaws at 10 × 10 cm2 and (2) with a 2 mm offset from the MLC edge, in line with the recommended geometry from IROC-H as part of their auditing program and published dataset. The [Formula: see text] factors for the three detectors were taken from the TRS483 CoP and other published works. The average differences of ROFs measured by detectors under MLC fields with fixed jaws and with 2 mm jaws offset for the 6 MV-WFF beam are 1.4% and 1.9%, respectively. Similarly, they are 2.3% and 2.4% for the 6MV-FFF beam. The relative differences between the detector-average ROFs and the corresponding IROC-H dataset are 2.0% and 3.1% for the 6 MV-WFF beam, while they are 2.4% and 3.2% for the 6MV-FFF beam at the smallest available field size of 2 × 2 cm2. For smaller field sizes, the average ROFs of the three detectors and corresponding results from Akino and Dufreneix showed the largest difference to be 6.6% and 6.2% under the 6 MV-WFF beam, while they are 3.4% and 3.6% under the 6 MV-WFF beam at the smallest field size of 0.5 × 0.5 cm2. Some well-published specific output correction factors for different small field detector types give better convergence in the calculation of the relative output factor in comparison with the generic data provided by the TRS-483 CoP. Relative output factor measurements should be performed as close as possible to the clinical settings including a combination of collimation systems, beam types and using at least three different types of small field detector for more accurate computation of the treatment planning system. The IROC-H dataset is not available for field size smaller than 2 × 2 cm2 for double checks and so that user should carefully check with other publications with the same setting.


Asunto(s)
Fotones , Radiometría , Fotones/uso terapéutico , Aceleradores de Partículas , Fantasmas de Imagen
15.
Asia Pac J Clin Oncol ; 20(2): 188-197, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37194387

RESUMEN

Cancer management is an expansive, growing, and evolving field. In the last decade or so, immunotherapy (IT) and particle beam therapy have made a tremendous impact in this domain. IT has already established itself as the fourth pillar of oncology. Recent emphasis has been centred around combination therapy, postulating additive or multiplicative effects of combining IT with one or more of the three conventional "pillars," that is, surgery, chemotherapy, and radiotherapy. Radio-IT is being increasingly explored and has shown promising outcomes in both preclinical and clinical settings. Particle beam therapy such as protons, when used as the radiotherapeutic modality in conjunction with IT, can potentially limit toxicities and improve this synergism further. Modern proton therapy has demonstrated a reduction in integral dose of radiation and radiation-induced lymphopenia in various sites. Protons, by virtue of their inherent clinically desirable physical and biological characteristics, namely, high linear energy transfer, relative biological effectiveness of range 1.1-1.6, and proven anti-metastatic and immunogenic potential in preclinical studies, might have a superior immunogenic profile than photons. Proton-IT combination is being studied currently by various groups in lung , head neck and brain tumors, and should be evaluated further in other subsites to replicate preclinical outcomes in a clinical setting. In this review, we summarize the currently available evidence for combinatorial approaches and feasibility of proton and IT combination, and thereafter highlight the emerging challenges for practical application of the same in clinics, while also proposing plausible solutions.


Asunto(s)
Neoplasias Encefálicas , Terapia de Protones , Oncología por Radiación , Humanos , Terapia de Protones/efectos adversos , Protones , Fotones/uso terapéutico
16.
Radiother Oncol ; 190: 109958, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37871751

RESUMEN

Proton radiotherapy offers a dosimetric advantage compared to photon therapy in sparing normal tissue, but the clinical evidence for toxicity reductions in the treatment of head and neck cancer is limited. The Danish Head and Neck Cancer Group (DAHANCA) has initiated the DAHANCA 35 randomised trial to clarify the value of proton therapy (NCT04607694). The DAHANCA 35 trial is performed in an enriched population of patients selected by an anticipated benefit of proton therapy to reduce the risk of late dysphagia or xerostomia based on normal tissue complication probability (NTCP) modelling. We present our considerations on the trial design and a test of the selection procedure conducted before initiating the randomised study.


Asunto(s)
Neoplasias de Cabeza y Cuello , Terapia de Protones , Radioterapia de Intensidad Modulada , Humanos , Protones , Neoplasias de Cabeza y Cuello/radioterapia , Terapia de Protones/métodos , Fotones/uso terapéutico , Probabilidad , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador , Dosificación Radioterapéutica
17.
J Appl Clin Med Phys ; 25(2): e14240, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38150580

RESUMEN

BACKGROUND: Monte Carlo (MC) simulations or measurements in anthropomorphic phantoms are recommended for estimating fetal dose in pregnant patients in radiotherapy. Among the many existing phantoms, there is no commercially available physical phantom representing the entire pregnant woman. PURPOSE: In this study, the development of a low-cost, physical pregnant female phantom was demonstrated using commercially available materials. This phantom is based on the previously published computational phantom. METHODS: Three tissue substitution materials (soft tissue, lung and bone tissue substitution) were developed. To verify Tena's substitution tissue materials, their radiation properties were assessed and compared to ICRP and ICRU materials using MC simulations in MV radiotherapy beams. Validation of the physical phantom was performed by comparing fetal doses obtained by measurements in the phantom with fetal doses obtained by MC simulations in computational phantom, during an MV photon breast radiotherapy treatment. RESULTS: Materials used for building Tena phantom are matched to ICRU materials using physical density, radiation absorption properties and effective atomic number. MC simulations showed that percentage depth doses of Tena and ICRU material comply within 5% for soft and lung tissue, up to 25 cm depth. In the bone tissue, the discrepancy is higher, but again within 5% up to the depth of 5 cm. When the phantom was used for fetal dose measurements in MV photon breast radiotherapy, measured fetal doses complied with fetal doses calculated using MC simulation within 15%. CONCLUSIONS: Physical anthropomorphic phantom of pregnant patient can be manufactured using commercial materials and with low expenses. The files needed for 3D printing are now freely available. This enables further studies and comparison of numerical and physical experiments in diagnostic radiology or radiotherapy.


Asunto(s)
Mujeres Embarazadas , Radiometría , Embarazo , Humanos , Femenino , Fotones/uso terapéutico , Planificación de la Radioterapia Asistida por Computador , Simulación por Computador , Fantasmas de Imagen , Método de Montecarlo , Dosificación Radioterapéutica
18.
Sci Rep ; 13(1): 21466, 2023 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-38052891

RESUMEN

In modern radiotherapy with photons, the absorbed dose outside the radiation field is generally investigated. But it is well known that the biological damage depends not only on the absorbed dose but also on LET. This work investigated the dose-average LET (LΔ,D) outside several small radiotherapy fields to provide information that can help for better evaluating the biological effect in organs at risk close to the tumour volume. The electron fluences produced in liquid water by a 6 MV X-rays Varian iX linac were calculated using the EGSnrc Monte Carlo code. With the electron spectra, LΔ,D calculations were made for eight open small square fields and the reference field at water depths of 0.15 cm, 1.35 cm, 9.85 cm and 19.85 cm and several off-axis distances. The variation of LΔ,D from the centre of the beam to 2 cm outside the field's edge depends on the field size and water depth. Using radiobiological data reported in the literature for chromosomal aberrations as an endpoint for the induction of dicentrics determined in Human Lymphocytes, we estimated the maximum low-dose relative biological effectiveness, (RBEM) finding an increase of up to 100% from the centre of the beam to 2 cm from the field's edge.


Asunto(s)
Transferencia Lineal de Energía , Radiometría , Humanos , Rayos X , Fotones/uso terapéutico , Método de Montecarlo , Aceleradores de Partículas , Agua , Dosificación Radioterapéutica
19.
Asian Pac J Cancer Prev ; 24(12): 4133-4138, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-38156848

RESUMEN

PURPOSE/OBJECTIVE: The purpose of this study is to investigate the effect of treatment couch and immobilization devices on surface dose for megavoltage photon beams. MATERIAL/METHODS: Percentage surface dose (PSD) measurement was carried out in Elekta Synergy™ Linear accelerator using PTW Markus® Parallel plate ionization chamber of volume 0.05cm3 with water equivalent RW3 Slab phantom (PTW, Germany). The measurement depth was considered at 0.07mm. The reference PSD was measured at 0° gantry angle with 10×10cm2, 20×20cm2 and 30×30cm2 field sizes and 100cm SSD for 4MV, 6MV and 15MV photon beams. For comparison, PSD measurement was carried out at 180° gantry angle inclusion of treatment couch (TC), All in One positioning system (AIO - PS) and Vac lok Cushions (VLC). RESULTS: Beam angle at 0°, for field sizes 10×10cm2, 20×20cm2 and 30×30cm2, the PSD was observed as 30.9%, 40.5%, 48.7% for 4MV; 23.7%, 33.8%, 42.2% for 6MV; and 17.0%, 29.6%, 38.6% for 15MV respectively. Beam angle at 180° with TC, an increase in PSD by maximum of 65.0% for 4MV, 64.9% for 6MV and 55.9% for 15MV as compared to 0° angle. The PSD increased when beam angle was 180° with TC and AIO - PS were 65.0% for 4MV, 67.4% for 6MV, and 60.9% for 15MV than 0° angle. Similarly, increased PSD for beam angle at 180° with TC and VLC were 66.8% for 4MV, 66.8% for 6MV and 61.3% for 15MV as compared to 0° angle. CONCLUSION: For all three-photon energies, at 180° gantry angle, the PSD increased significantly in case of TC, VLC, and AIO - PS for all the field sizes as compared to gantry angle at 0°. It is necessary to consider TC, AIO - PS and VLC during dose calculation to ensure accuracy of patient treatment delivery.


Asunto(s)
Fotones , Planificación de la Radioterapia Asistida por Computador , Humanos , Fotones/uso terapéutico , Fantasmas de Imagen , Aceleradores de Partículas , Agua , Dosificación Radioterapéutica
20.
Acta Oncol ; 62(11): 1412-1417, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37815913

RESUMEN

BACKGROUND: Patients with head and neck squamous cell carcinoma of unknown primary (HNCUP) are often treated with extensive radiotherapy (RT). Frequently, the bilateral nodal clinical target volume (nCTV) and the volumes of suspected mucosal primary sites (mCTV) of the pharynx and larynx is irradiated. This treatment is effective but toxic. New data suggest that omission of the contralateral nCTV and mCTV, results in few recurrences. The present study explores photon versus proton therapy, in the primary and recurrent setting. MATERIAL AND METHODS: An analysis of twelve patients previously treated for HNCUP was performed. A fictitious recurrence was defined in patients treated for unilateral disease. Independently a volumetric arc photon plan and an intensity-modulated proton plan was made for all cases and scenarios. RESULTS: Compared to the standard bilateral treatment this study shows that limiting the target to unilateral nCTV leads to a significant decrease in dysphagia of 18% and 17% and xerostomia of 4.0% and 5% for photon and protons, respectively. Comparing photon RT directly to proton RT shows a small and often insignificant gain, using protons for both bilateral and unilateral targets. Focusing on re-irradiation, benefits from using protons in both the primary setting and at re-irradiation were limited. However, using protons for re-irradiation only leads to a decrease in the tissue volume receiving a specific dose outside the target overlapping region, e.g., V90Gymean was 31, 25, and 22 cm3 for photons-photons, photons-protons, and protons-protons, respectively. For V100Gy of the ipsilateral carotid artery, no differences were observed. CONCLUSION: Omitting contralateral nCTV irradiation and mCTV irradiation will significantly reduce toxicity. The accumulated high dose volumes can be minimised using protons for re-irradiation. However, the use of protons for primary treatment provides limited benefit in most patients.


Asunto(s)
Neoplasias de Cabeza y Cuello , Neoplasias Primarias Desconocidas , Terapia de Protones , Radioterapia de Intensidad Modulada , Humanos , Protones , Carcinoma de Células Escamosas de Cabeza y Cuello/radioterapia , Dosificación Radioterapéutica , Terapia de Protones/efectos adversos , Terapia de Protones/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/efectos adversos , Radioterapia de Intensidad Modulada/métodos , Fotones/uso terapéutico , Neoplasias de Cabeza y Cuello/radioterapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...