1.
Vet Surg ; 53(6): 1052-1061, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39088191

RESUMEN

OBJECTIVE: To compare the efficacy and clinical outcomes of computed tomography (CT)-based virtual surgical planning (VSP) and a three-dimensional (3D)-printed, patient-specific reduction system to conventional indirect reduction techniques for diaphyseal tibial fractures stabilized using minimally invasive plate osteosynthesis (MIPO) in dogs. STUDY DESIGN: A prospective clinical study with a historic control cohort. SAMPLE POPULATION: Dogs undergoing MIPO stabilization of diaphyseal tibial fractures using a custom 3D-printed reduction system (3D-MIPO; n = 15) or conventional indirect reduction techniques (c-MIPO; n = 14). METHODS: Dogs were prospectively enrolled to the 3D-MIPO group and CT scans were used to design and fabricate a custom 3D-printed reduction system to facilitate MIPO. Medical records were searched to identify dogs for the c-MIPO group. Pre-, intra- and postoperative parameters were compared between groups. RESULTS: The duration from presentation until surgery was 23 h longer in the 3D-MIPO group (p = .002). Fewer intraoperative fluoroscopic images were acquired (p < .001) and mean surgical duration was 34 min shorter in the 3D-MIPO group (p = .014). Median postoperative tibial length, frontal alignment, and sagittal alignment were within 4 mm, 3° and 3°, respectively, of the contralateral tibia in both groups and did not differ between reduction groups (p > .1). Postoperative complications occurred in 27% and 14% of fractures in the 3D-MIPO and c-MIPO groups, respectively. CONCLUSION: Both reduction methods yielded comparable results. Although the preoperative planning and guide preparation was time consuming, surgery times were shorter and fluoroscopy use was less in the 3D-MIPO group. CLINICAL SIGNIFICANCE: VSP and the custom 3D-printed reduction system facilitated efficient MIPO.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas , Impresión Tridimensional , Fracturas de la Tibia , Animales , Perros/cirugía , Perros/lesiones , Fijación Interna de Fracturas/veterinaria , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/veterinaria , Fracturas de la Tibia/diagnóstico por imagen , Placas Óseas/veterinaria , Masculino , Femenino , Estudios de Casos y Controles , Estudios Prospectivos , Tomografía Computarizada por Rayos X/veterinaria , Procedimientos Quirúrgicos Mínimamente Invasivos/veterinaria , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Enfermedades de los Perros/cirugía , Cirugía Asistida por Computador/veterinaria , Cirugía Asistida por Computador/métodos
2.
Vet Surg ; 53(6): 1039-1051, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38850094

RESUMEN

OBJECTIVE: To evaluate the efficacy of a three-dimensional (3D)-printed, patient-specific reduction system for aligning diaphyseal tibial fractures stabilized using minimally invasive plate osteosynthesis (MIPO). STUDY DESIGN: Prospective clinical trial. SAMPLE POPULATION: Fifteen client owned dogs. METHODS: Virtual 3D models of both pelvic limbs were created. Pin guides were designed to conform to the proximal and distal tibia. A reduction bridge was designed to align the pin guides based on the guides' spatial location. Guides were 3D printed, sterilized, and applied, in conjunction with transient application of a circular fixator, to facilitate indirect fracture realignment before plate application. Alignment of the stabilized tibiae was assessed using postoperative computed tomography scans. RESULTS: Mean duration required for virtual planning was 2.5 h and a mean of 50.7 h elapsed between presentation and surgery. Guide placement was accurate with minor median discrepancies in translation and frontal, sagittal, and axial plane positioning of 2.9 mm, 3.6°, 2.7°, and 6.8°, respectively. Application of the reduction system restored mean tibial length and frontal, sagittal, and axial alignment within 1.7 mm, 1.9°, 1.7°, and 4.5°, respectively, of the contralateral tibia. CONCLUSION: Design and fabrication of a 3D-printed, patient-specific fracture reduction system is feasible in a relevant clinical timeline. Intraoperative pin-guide placement was reasonably accurate with minor discrepancies compared to the virtual plan. Custom 3D-printed reduction system application facilitated near-anatomic or acceptable fracture reduction in all dogs. CLINICAL SIGNIFICANCE: Virtual planning and fabrication of a 3D-printing patient-specific fracture reduction system is practical and facilitated acceptable, if not near-anatomic, fracture alignment during MIPO.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas , Impresión Tridimensional , Fracturas de la Tibia , Animales , Perros/lesiones , Perros/cirugía , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/veterinaria , Fijación Interna de Fracturas/veterinaria , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Placas Óseas/veterinaria , Estudios Prospectivos , Masculino , Femenino , Procedimientos Quirúrgicos Mínimamente Invasivos/veterinaria , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación
3.
Vet Surg ; 53(6): 1009-1018, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38923543

RESUMEN

OBJECTIVE: Medical records for dogs treated with tibial plateau leveling osteotomy (TPLO) using Arthrex 3.5 mm self-tapping screws (STS) were evaluated to determine the incidence rate of transcortical tibial fractures (TCTF) and development of complications. STUDY DESIGN: Retrospective case report. STUDY POPULATION: A total of 78 dogs. METHODS: Dogs that underwent a TPLO performed from March 2022 to August 2023 were reviewed. Postoperative TPLO radiographs were examined for evidence of a TCTF with Arthrex 3.5 mm STS. Records were reviewed for complications up to 14 weeks after surgery. RESULTS: Evidence of a TCTF was found in 42% of cases (33 of 78) and 14% (36 of 250) of STS screws distal to the osteotomy. TCTFs were only identified distal to the osteotomy. Three dogs had radiographic evidence of more than one TCTF. Of the dogs with radiographic TCTF, 6% of patients (2 of 33) developed a major complication that required surgical stabilization of a tibial fracture associated with screw angulation relative to the plate. CONCLUSION: Use of Arthrex 3.5 mm STS for TPLO is associated with risk of TCTF. TCTF can compromise the structural properties of the tibia and cause complete tibial fracture requiring major revision surgery. CLINICAL SIGNIFICANCE: Development of TCTF after use of STS for TPLO has been recognized, in contrast to use of non-self-tapping screws, and was considered a benign complication. Our findings suggest TCTF associated with Arthrex 3.5 mm STS use in TPLO can contribute to major complications after surgery, including complete tibial fracture, particularly if screws are not placed perpendicular to the plate.


Asunto(s)
Tornillos Óseos , Osteotomía , Fracturas de la Tibia , Animales , Perros/lesiones , Osteotomía/veterinaria , Osteotomía/efectos adversos , Osteotomía/métodos , Fracturas de la Tibia/veterinaria , Fracturas de la Tibia/cirugía , Tornillos Óseos/veterinaria , Tornillos Óseos/efectos adversos , Estudios Retrospectivos , Femenino , Masculino , Enfermedades de los Perros/cirugía , Tibia/cirugía , Complicaciones Posoperatorias/veterinaria
4.
Vet Surg ; 53(6): 1029-1038, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38519857

RESUMEN

OBJECTIVE: To report the surgical approaches and stabilization of lateral and medial tibial plateau fractures (TPF), as well as the long-term outcome following repair. STUDY DESIGN: Prospective series of three client-owned dogs. ANIMALS: Three dogs. METHODS: For the two lateral TPF cases (Unger type 41-B1), the surgical approach included separation of the lateral collateral ligament and long digital extensor tendon. The lateral meniscus was elevated to allow visualization of the tibial surface and assess fracture reduction. The first case was repaired using two 2.0 mm lag screws (with washers). The second case sustained a lateral TPF, fibular fracture and concurrent tubercle of Gerdy fracture. Both tibial fractures were stabilized using two 2.0 mm lag screws with washers and two 0.9 mm Kirschner wires (K-wires). A third case, diagnosed with an Unger type 41-B2 medial TPF, was treated using 0.9 mm K-wires and 22-gauge tension band. RESULTS: There were no major complications noted. One minor complication occurred (screw yield two weeks postoperatively). By 8 weeks, all patients reached clinical union with good limb function. Owners were contacted 9-36 months postoperatively. LOAD scores and examinations were performed for two of three patients; the third patient was not contactable after relocating out of state. Both cases with completed questionnaires had a LOAD score of 5/52. CONCLUSION: Tibial plateau fractures are rare in canine patients. While challenging, they can be successfully managed using a combination of lag screws, K-wires, and tension band. CLINICAL SIGNIFICANCE: Surgical stabilization of TPF is feasible and may reduce the risk of meniscal injury.


Asunto(s)
Fijación Interna de Fracturas , Fracturas de la Tibia , Perros/lesiones , Animales , Fracturas de la Tibia/veterinaria , Fracturas de la Tibia/cirugía , Masculino , Fijación Interna de Fracturas/veterinaria , Fijación Interna de Fracturas/métodos , Femenino , Estudios Prospectivos , Resultado del Tratamiento , Tornillos Óseos/veterinaria , Hilos Ortopédicos/veterinaria , Enfermedades de los Perros/cirugía , Fracturas de la Meseta Tibial
5.
Vet Med Sci ; 10(2): e1382, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38375978

RESUMEN

The jungle cat (Felis chaus) is a member of the genus Felis within the family Felidae, native to south-east Asia, west Asia and north Africa. A 2-year-old male jungle cat was referred with a history of lameness of 3 days duration. At the time of presentation, the animal had non-weight-bearing lameness of the right hindlimb. Examination identified crepitation and instability in the distal diaphyseal region of the right tibial bone. Radiographs confirmed the presence of fractures in the distal diaphyseal region of the right tibia and fibula. Double plating of the tibia was employed for used fixation. The animal was evaluated 2, 4 and 8 weeks post-operatively, and the procedure was considered to have been successful with no observed surgical complications.


Asunto(s)
Felis , Fracturas de la Tibia , Masculino , Animales , Cojera Animal , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/veterinaria , Peroné/cirugía
6.
Vet Comp Orthop Traumatol ; 36(5): 266-272, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37336471

RESUMEN

OBJECTIVE: The aim of this study was to describe the use of a procedure-specific fixation method for tibial tuberosity transposition and report clinical outcome. STUDY DESIGN: This is a multi-institutional case series, evaluating 37 cases that were treated surgically for medial patellar luxation (MPL) and in which the tibial tuberosity transposition (TTT) was performed using the Rapid Luxation Plating System (RLPS). Surgical technique, implants, clinical outcome, and complications are reported. RESULTS: Surgery was successfully performed in dogs weighing 2.5 to 36.2 kg. Postoperative minor complications occurred in 13 cases (35%) and major complications occurred in 3 cases (8%). No implant-related complications or tibial tuberosity avulsions or fractures were seen. Outcome related to surgery was good or excellent in all cases. CONCLUSION: The RLPS for TTT provides a feasible technique in a large range of patients with MPL and lowers the occurrence of implant-related complications and tibial tuberosity avulsion or fracture.


Asunto(s)
Enfermedades de los Perros , Luxaciones Articulares , Luxación de la Rótula , Fracturas de la Tibia , Animales , Perros , Enfermedades de los Perros/cirugía , Luxaciones Articulares/veterinaria , Luxación de la Rótula/veterinaria , Complicaciones Posoperatorias/veterinaria , Estudios Retrospectivos , Tibia/cirugía , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/veterinaria
7.
Vet Surg ; 52(5): 739-746, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37073566

RESUMEN

OBJECTIVE: To determine whether one larger or two smaller diameter pins used for tibial tuberosity avulsion fracture (TTAF) stabilization provides greater axial tensile strength and stiffness when subjected to monotonic mechanical load to failure in normal skeletally mature canine cadavers. STUDY DESIGN: Paired ex vivo biomechanical study. SAMPLE POPULATION: Eleven pairs of adult cadaveric dog tibias. METHODS: Twenty-two tibias from 11 dogs were collected to model a TTAF. Each limb of a pair was randomly assigned a one or two-pin fixation. Tibias were subjected to monotonic, axial load to failure. Fixation stiffness, strength, and pin insertion angles were analyzed with parametric testing. Significance was set at p < .05. RESULTS: The mean strength of the single-pin fixation was 426.2 ± 50.5 N compared to two-pin fixation at 639.2 ± 173.5 N (p = .003). The mean stiffness of the single-pin fixation was 57.3 ± 18.7 N/mm and the two-pin fixation was 71.7 ± 20.5 N/mm (p = .029). The normalized ratio between one and two-pin fixation had a mean stiffness of 68% ± 25.8% and strength of 82.8% ± 24.6%. CONCLUSIONS: In an ex vivo cadaveric TTAF model, vertically aligned two-pin fixation offers greater strength and stiffness when compared to a single-pin fixation. CLINICAL SIGNIFICANCE: When repairing TTAF, surgeons should aim to apply two vertically aligned pins rather than a single pin for greater strength and stiffness.


Asunto(s)
Enfermedades de los Perros , Fracturas por Avulsión , Fracturas de la Tibia , Perros , Animales , Fracturas por Avulsión/veterinaria , Clavos Ortopédicos/veterinaria , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/veterinaria , Tibia/cirugía , Cadáver , Fenómenos Biomecánicos , Fijación de Fractura/veterinaria
8.
J Vet Sci ; 24(2): e28, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37012036

RESUMEN

A three-year-old female spayed Lurcher was referred for the treatment of a highly comminuted distal tibial articular fracture. Resection of the area of comminution with a transverse osteotomy of the tibial diaphysis and talar ridges was performed, followed by modified pantarsal arthrodesis and a calcaneotibial screw. The treatment resulted in 7 cm of tibial shortening, equating to a 28% reduction in the total tibial length. Radiographic union of the arthrodesis was successful. Fair use of the pelvic limb was documented long-term. Combined acute limb shortening and modified pantarsal arthrodesis resulted in an acceptable outcome and could be considered in cases of highly comminuted distal tibial fractures.


Asunto(s)
Enfermedades de los Perros , Fracturas Conminutas , Fracturas de la Tibia , Femenino , Perros , Animales , Resultado del Tratamiento , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/veterinaria , Tibia/cirugía , Fracturas Conminutas/diagnóstico por imagen , Fracturas Conminutas/cirugía , Fracturas Conminutas/veterinaria , Artrodesis/veterinaria , Enfermedades de los Perros/cirugía
9.
Vet Med Sci ; 9(2): 591-599, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36639946

RESUMEN

A 10-week-old male, Xoloitzcuintle (Mexican hairless dog), weighing 8.9 kg was presented after its owner accidentally stepped on its paw. The dog presented with acute pain, inflammation and grade IV lameness in the right hind paw. A complete transverse fracture in the right proximal tibia was diagnosed from radiography. The dog underwent a minimally invasive plate osteosynthesis (MIPO) procedure. After surgery, photobiomodulation therapy combined with static magnetic field (PBMT-sMF) was applied twice daily for 21 days. A multi-wavelength PBMT-sMF device was applied at three sites using different frequencies: proximal and distal of the fracture zone (3000 Hz, 40.35 J per site, and 300 s per site) and in the fracture zone (250 Hz, 39.11 J and 300 s per site). Follow up radiographies were performed after surgery and treatment with PBMT-sMF. Eighteen days post-surgery the healing process of bone was advanced. Fifty-five days post-surgery the callus was enlarged. In addition, radiographic union and clinical union was evidenced by closure of the fracture gap. This case report has reported the use of PBMT-sMF in order to accelerate and improve bone healing following a MIPO procedure on a complete transverse fracture in the proximal tibia of a puppy.


Asunto(s)
Enfermedades de los Perros , Terapia por Luz de Baja Intensidad , Fracturas de la Tibia , Masculino , Perros , Animales , Tibia/cirugía , Curación de Fractura , Terapia por Luz de Baja Intensidad/veterinaria , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/veterinaria , Campos Magnéticos , Enfermedades de los Perros/radioterapia , Enfermedades de los Perros/cirugía
10.
Vet Surg ; 52(2): 249-256, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36382668

RESUMEN

OBJECTIVE: The objective of this study was to evaluate the use of linear external skeletal fixation (ESF) applied using minimally invasive techniques in dogs and cats. STUDY DESIGN: Retrospective study. ANIMALS: Forty-nine dogs and 6 cats. METHODS: Medical records of cases with nonarticular tibial fractures, repaired using linear ESF at a single academic institution between July 2010 and 2020, were reviewed. All records of cases that had nonarticular tibial fractures repaired using linear ESF were included. Information was collected regarding signalment, surgical procedures performed, perioperative care, radiographic evaluation, and postoperative complications. RESULTS: Intraoperative imaging was used in 40/55 (72%) of cases. Tibal plateau angle (TPA), tibial mechanical medial proximal and distal tibial angles (mMPTA and mMDTA, respectively) were not affected by intraoperative imaging (P = .344, P = .687, P = .418). A total of 22 (40%) complications occurred. Of these, 18 were considered minor and 4 were considered major. Open fractures had more major complications than closed fractures (P = .019). All fractures reached radiographic union of the fracture. The mean ± SD time to external fixator removal was 71 ± 48 days. CONCLUSION: Linear ESF applied using minimally invasive techniques with or without intraoperative imaging was an effective treatment for nonarticular tibial fractures. CLINICAL SIGNIFICANCE: Closed application of linear ESF should be considered as a minimally invasive option for stabilizing nonarticular tibial fractures.


Asunto(s)
Enfermedades de los Gatos , Enfermedades de los Perros , Fracturas de la Tibia , Gatos , Perros , Animales , Estudios Retrospectivos , Enfermedades de los Gatos/diagnóstico por imagen , Enfermedades de los Gatos/cirugía , Placas Óseas/veterinaria , Enfermedades de los Perros/cirugía , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/veterinaria , Fijación de Fractura/veterinaria , Fijadores Externos/veterinaria , Resultado del Tratamiento , Procedimientos Quirúrgicos Mínimamente Invasivos/veterinaria , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos
11.
Vet Comp Orthop Traumatol ; 36(1): 53-62, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36150695

RESUMEN

OBJECTIVE: Our objectives were to report complications associated with stabilization of long-bone fractures in cats using a 3.5-mm titanium interlocking nail and to examine the influences of signalment, fracture type and fixation evaluations on the occurrence of complications. STUDY DESIGN: Retrospective clinical study. MATERIAL AND METHODS: Medical and radiographic records of cats with long-bone fractures treated with an interlocking nail were reviewed. Data included age, sex, weight, cause of the fracture, fractured bone(s) and fracture type. Complications were classified as minor and major complications. Fisher's exact tests and logistic regression analysis were used to test whether certain variables of signalment and interlocking nail configuration had an effect on the occurrence of complications. RESULTS: Sixty-seven fractures of 67 cats were examined in this study. Forty-eight femora, sixteen tibiae and three humeri were included. Complications occurred in 11/67 fractures. Major complications occurred in 8/67 fractures and included screw breakage (n = 3), nail breakage (n = 2), nail bending (n = 1), screw loosening (n = 1), non-union (n = 1). Statistical analysis showed a significant difference between fracture types and the occurrence of major complications (p = 0.02). CONCLUSION: In conclusion, use of this commercially available standard 3.5-mm titanium interlocking nail for stabilization of comminuted and oblique humeral, femoral and tibial fractures in cats is feasible.


Asunto(s)
Enfermedades de los Gatos , Fracturas del Fémur , Fijación Intramedular de Fracturas , Fracturas del Húmero , Fracturas de la Tibia , Gatos/cirugía , Animales , Titanio , Fijación Intramedular de Fracturas/veterinaria , Clavos Ortopédicos/veterinaria , Estudios Retrospectivos , Fracturas del Húmero/diagnóstico por imagen , Fracturas del Húmero/cirugía , Fracturas del Húmero/veterinaria , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/veterinaria , Fracturas del Fémur/cirugía , Fracturas del Fémur/veterinaria , Enfermedades de los Gatos/cirugía
12.
Vet Rec ; 192(3): e2344, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36349546

RESUMEN

BACKGROUND: Limb fractures represent the most common orthopaedic disease in pet rabbits. However, only a few studies have evaluated therapeutic details of limb fractures. There are no data available for long-term outcomes of limb fracture treatment. METHODS: The medical records of six institutions were reviewed retrospectively to identify cases of traumatic limb bone fractures in pet rabbits between 1999 and 2020. The medical records (n = 387) were analysed for details of fracture prevalence, aetiology, therapy protocols, treatment complications, outcome and long-term effects. In addition to the retrospective data evaluation, 13 rabbits were re-evaluated in person in recent clinical analyses, including orthopaedic examination, radiography and computed-tomographic imaging. Details of long-term effects of fracture treatment were requested over the telephone for a further 232 animals using a standardised questionnaire. RESULTS: Long bone fractures accounted for the majority of all fractures (296/387; 76.5%). Hindlimb fractures (301/387; 77.7%) were more common than forelimb fractures (86/387; 22.2%), and tibial fractures and combined fractures of the tibia and fibula (119/387; 30.8%) were observed most frequently. Most fracture treatments were based on osteosynthesis procedures (243/328; 74.1%). Treatment complications occurred in 130 out of 328 (39.6%) cases. A high bodyweight (p = 0.047) and an older age (p = 0.01) were found to be significant risk factors for the emergence of therapy complications. Overall, 75.4% of animals (175/232) had a satisfactory long-term outcome. Limb posture anomalies were evaluated in 61 cases (26.3%). LIMITATIONS: The multi-centre approach led to the inclusion of various institutions, veterinarians, treatment protocols and rabbit populations that might have influenced the results. The medical records were reviewed retrospectively, so there were some data that were lacking or could not be collected in a standardised manner. Furthermore, rabbit owners' evaluation of long-term outcomes might be prone to error, despite the use of a standardised interview questionnaire. CONCLUSION: Limb fractures are a common orthopaedic issue in pet rabbits. The patient's bodyweight and age are significant risk factors for the emergence of complications during the fracture treatment process. Long-term orthopaedic effects, such as abnormal limb posture and permanent lameness of the affected limb, were observed regularly.


Asunto(s)
Fracturas de la Tibia , Conejos , Animales , Estudios Retrospectivos , Fracturas de la Tibia/epidemiología , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/veterinaria , Fijación Interna de Fracturas/veterinaria , Extremidades , Tibia , Resultado del Tratamiento
13.
Equine Vet J ; 55(2): 171-181, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35569040

RESUMEN

Equine tibial fractures are relatively infrequent in racing and non-racing sport horses, but limitations in successful treatment of tibial fractures in adult horses result in relatively high mortality compared with other musculoskeletal injuries. The aetiology of tibial fracture can be classified into two general categories: traumatic impact or fatigue failure. Tibial stress fractures, also known as fatigue fractures, are often rated as the second most common stress fracture in racing Thoroughbreds; young age, early stage in race training, and initiation of training after a period of rest are the reported risk factors. Both impact and fatigue fracture propagation are dependent on the magnitude of force applied and on the local composition/alignment of mineralised collagen in the tibial lamella. Extensive research has characterised the pattern of strain distribution and stress remodelling within the equine tibia, but in vivo measurement of load and angular moments are currently not feasible. Further research is warranted to correlate biomechanical theory of tibia fatigue fracture propagation with current histopathological data. Preventative measures for fatigue fractures aim to optimise diagnostic efficiency, reduce the interval between injury and diagnosis and modify racing and training conditions to reduce non-specific fracture risk. Treatment options for complete tibial fractures in adult horses are limited, but with careful case selection, successful outcomes have been reported after open reduction and internal fixation. On the other hand, tibial stress fractures and minimally displaced incomplete fractures are typically treated conservatively and have good prognosis for athletic recovery. This review aims to describe the current literature regarding tibial fracture aetiology, prevalence, risk factors, fracture biomechanics, treatment, prognosis and prevention.


Asunto(s)
Fracturas por Estrés , Enfermedades de los Caballos , Condicionamiento Físico Animal , Deportes , Fracturas de la Tibia , Caballos , Animales , Fracturas por Estrés/diagnóstico , Fracturas por Estrés/veterinaria , Condicionamiento Físico Animal/efectos adversos , Fracturas de la Tibia/veterinaria , Fracturas de la Tibia/epidemiología , Fracturas de la Tibia/etiología , Pronóstico , Enfermedades de los Caballos/terapia
14.
Open Vet J ; 13(12): 1744-1751, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38292707

RESUMEN

Background: Pediatric fractures are relatively common in dogs, and several treatment options exist, particularly for fractures in the distal extremities. Regardless of the choice of treatment, the overall goal is rapid restoration and excellent long-term functional recovery, with minimal discomfort and morbidity during healing. This case series aims to report the long-term outcome after minimally invasive percutaneous elastic plate osteosynthesis (MIPEPO) in the treatment of pediatric tibial fractures in dogs and compare this to other treatment options, where all techniques emphasize biological osteosynthesis. We especially accentuate surgery time, patient comfort level during osteosynthesis, time to clinical union, and complications, including long-term follow-up. Case Description: Medical records of five skeletally immature (juvenile) dogs <6 months old with an isolated tibial diaphyseal fracture or a combination of tibial and fibular diaphyseal fractures, treated with MIPEPO aided by fluoroscopy. All dogs experienced excellent levels of comfort and limb functionality and exhibited preserved muscle mass throughout the healing process. The mean duration until plate removal was 27.6 days, with a standard deviation [(SD) ± 9.61; range of 15-36 days] following the operation. Subsequently, four dogs underwent a follow-up examination approximately 1.5 years after plate removal, during which bilateral orthogonal radiographs of the tibia were obtained. These radiographs revealed minimal discrepancies in terms of limb length, frontal plane alignment, and rotational alignment. Furthermore, the owners expressed complete satisfaction with their dogs' recovery and restoration of intended function. Conclusion: MIPEPO is quick to perform and well tolerated, with rapid fracture healing in juvenile dogs and excellent long-term outcomes. It can be considered along with external fixators and external coaptation when dealing with juvenile diaphyseal fractures.


Asunto(s)
Enfermedades de los Perros , Fracturas de la Tibia , Perros , Animales , Tibia , Procedimientos Quirúrgicos Mínimamente Invasivos/veterinaria , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/veterinaria , Fijación Interna de Fracturas/veterinaria , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/métodos , Curación de Fractura , Enfermedades de los Perros/etiología
15.
Vet Rec ; 191(12): e2279, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36264666

RESUMEN

BACKGROUND: This study is a retrospective review of the demography, management, complications and outcomes of canine physeal fractures. METHODS: Clinical records were reviewed for dogs with appendicular physeal fractures, and descriptive statistical analysis was applied to the data set. RESULTS: One hundred and three fractures were included, of which 68 had follow-up. Fractures of the distal humerus were the most common (n = 57), followed by proximal tibial fractures (n = 16). Outcome was fair for most fractures at all locations, aside from the distal humerus, where most outcomes were good. At radiographic follow-up, most physes were closed at all locations aside from the distal tibia. Implant removal to allow ongoing physeal growth was performed in only 3/18 (17%) fractures, in 15/18 (83%) implant removal related to complications. LIMITATIONS: Only short-term follow-up data were present, and hence it is not possible to give a longer term indication of return to function. CONCLUSIONS: The management and demography of canine physeal fractures have evolved considerably from previous publications. Routine implant removal to allow ongoing growth was not regularly performed at all locations in this cohort.


Asunto(s)
Enfermedades de los Perros , Fracturas de la Tibia , Perros , Animales , Fracturas de la Tibia/veterinaria , Epífisis , Placa de Crecimiento , Estudios Retrospectivos , Demografía , Enfermedades de los Perros/cirugía
16.
Vet Surg ; 51(8): 1231-1239, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36169234

RESUMEN

OBJECTIVE: To evaluate the inter- and intra-rater reliability of the tibial plateau leveling osteotomy (TPLO) modified radiographic union scale for tibial fractures (mRUST), a semiquantitative scoring system, as compared with the subjective evaluation of radiographic union for staged TPLOs. STUDY DESIGN: Retrospective study. ANIMALS: Forty-eight dogs, 96 stifles. METHODS: Medical records were reviewed for dogs with bilateral cranial cruciate ligament injuries diagnosed at presentation that underwent staged bilateral TPLOs within 6 months and had both immediate and recheck postoperative radiographs. Radiographs were anonymized, reviewers were blinded, radiographic union was evaluated subjectively, and TPLO mRUST scores were assigned. RESULTS: The subjective evaluation's intra-rater reliability was 0.72 (Kappa 95% CI 0.65-0.79) and inter-rater reliability was 0.33 (Kappa 95% CI 0.28-0.39). The TPLO mRUST scoring system intra-rater reliability was 0.73 (95% CI 0.68-0.78) and inter-rater reliability was 0.56 (95% CI 0.41-0.68). There was no difference in the degree of bone healing quantified by the TPLO mRUST scoring system (95% CI - 0.1-1.2, P = .09) or subjective evaluation (P = .48) between the first and second side TPLOs. The TPLO mRUST scores were positively correlated with subjective healing (r = 0.94, 95% CI 0.92-0.96, P < .0001, and for scores ≥10/12, 99%, 244/246) were subjectively assigned as radiographically healed. CONCLUSION: The TPLO mRUST scoring system improved inter-rater reliability compared to subjective evaluation of radiographic union. CLINICAL SIGNIFICANCE: The TPLO mRUST scoring system should be considered as a semiquantitative supplemental tool for evaluating radiographic union.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Enfermedades de los Perros , Fracturas de la Tibia , Perros , Animales , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/veterinaria , Ligamento Cruzado Anterior/diagnóstico por imagen , Ligamento Cruzado Anterior/cirugía , Estudios Retrospectivos , Reproducibilidad de los Resultados , Osteotomía/veterinaria , Osteotomía/métodos , Tibia/diagnóstico por imagen , Tibia/cirugía , Tibia/lesiones , Rodilla de Cuadrúpedos/cirugía , Lesiones del Ligamento Cruzado Anterior/diagnóstico por imagen , Lesiones del Ligamento Cruzado Anterior/cirugía , Lesiones del Ligamento Cruzado Anterior/veterinaria , Enfermedades de los Perros/diagnóstico por imagen , Enfermedades de los Perros/cirugía
17.
Am J Vet Res ; 83(9)2022 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-35895760

RESUMEN

OBJECTIVE: To assess the feasibility and accuracy of using 2 methods for reduction and alignment of simulated comminuted diaphyseal tibial fractures in conjunction with 3-D-printed patient-specific pin guides. SAMPLE: Paired pelvic limbs from 8 skeletally mature dogs weighing 20 to 35 kg. METHODS: CT images of both tibiae were obtained, and 3-D reconstructions of the tibiae were used to create proximal and distal patient-specific pin guides. These guides were printed and used to facilitate fracture reduction and alignment in conjunction with either a 3-D-printed reduction guide or a linear type 1A external fixator. Postreduction CT images were used to assess the accuracy of pin guide placement and the accuracy of fracture reduction and alignment. RESULTS: The 3-D-printed guides were applied with acceptable ease. Guides for both groups were placed with minor but detectable deviations from the planned location (P = .01), but deviations were not significantly different between groups. Fracture reduction resulted in similar minor but detectable morphological differences from the intact tibiae (P = .01). In both groups, fracture reduction and alignment were within clinically acceptable parameters for fracture stabilization by means of minimally invasive plate osteosynthesis. CLINICAL RELEVANCE: Virtual surgical planning and fabrication of patient-specific 3-D-printed pin guides have the potential to facilitate fracture reduction and alignment during use of minimally invasive plate osteosynthesis for fracture stabilization.


Asunto(s)
Enfermedades de los Perros , Fracturas de la Tibia , Animales , Placas Óseas/veterinaria , Cadáver , Perros , Fijadores Externos , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/veterinaria , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/veterinaria , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/veterinaria
18.
Vet Comp Orthop Traumatol ; 35(3): 184-190, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35679872

RESUMEN

OBJECTIVE: The aim of this study was to evaluate factors contributing to the need for non-elective explant following surgical repair of tibial tuberosity avulsion fractures. STUDY DESIGN: Retrospective multicentre case-control study. Over a 5-year period, dogs (n = 63) that underwent surgical repair of tibial tuberosity avulsion fractures (n = 64) were considered. Dogs that underwent a non-elective explant were compared with those that did not. Continuous variables were compared with the Mann-Whitney U test. Categorical variables were compared with the Fisher's exact test. Variables which were significant on univariate analysis were entered into a multiple logistic regression model. Significance was set at p < 0.05. RESULTS: Non-elective explant was performed in 20/64 fractures and elective explant was performed in 2/64 fractures. Neutered dogs were found to be 19 times (95% confidence interval: 2.1-172) more likely to require explant compared with intact dogs (p = 0.009). Every 0.25 mm increase in average pin size was found to make it 2.5 times (95% confidence interval: 1.3-4.9) more likely to require explant (p = 0.006). CONCLUSION: The findings suggest that use of the smallest appropriate pin should be considered for standard surgical repair of tibial tuberosity avulsion fractures to minimize the risk of requiring non-elective explant.


Asunto(s)
Enfermedades de los Perros , Fracturas por Avulsión , Fracturas de la Tibia , Animales , Estudios de Casos y Controles , Enfermedades de los Perros/cirugía , Perros , Fijación Interna de Fracturas/veterinaria , Fracturas por Avulsión/veterinaria , Estudios Retrospectivos , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/veterinaria
19.
BMC Vet Res ; 18(1): 183, 2022 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-35578200

RESUMEN

BACKGROUND: One of the traumatic fractures occurring in the hindlimb of the foals is physeal fractures of the tibia. The most common type of proximal tibial fracture in foals is reported to be Salter-Harris type II. CASE PRESENTATION: This case report describes the history, clinical signs, radiographic findings, and surgical management of a proximal physeal fracture of the tibia due to the kick trauma in a 2-weeks-old Kurdish female foal, with signs of left pelvic limb lameness, valgus deviation with non-weight-bearing, non-mobility in stifle region and crepitation in the affected area. In this case, radiography was utilized to confirm the fracture and detect the exact location of the fracture fragments. The Salter-Harris type I accompanied by tibial tuberosity fracture was diagnosed. In this case, a size 4.5 mm seven-hole, T-plate, and cortical bone screws were employed to fix the physeal fracture, and a cortical bone screw was utilized to fix the tibial tuberosity in the normal position. Case follow-up during two months showed no significant complications, and the patient was fully recovered (no lameness anymore). CONCLUSIONS: To our knowledge, this is the first report of Salter-Harris type I fracture in proximal tibia accompanied by tibial tuberosity fracture in a foal treated by a T-plate implant. A cortical screw in lag fashion for tibial tuberosity was utilized in this case for the first time, and the results were satisfying. T-Plate fixation can be recommended as an effective surgical treatment for proximal tibial fractures in foals.


Asunto(s)
Enfermedades de los Caballos , Fracturas de la Tibia , Animales , Placas Óseas/veterinaria , Tornillos Óseos/veterinaria , Femenino , Caballos , Radiografía , Tibia/diagnóstico por imagen , Tibia/cirugía , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/veterinaria
20.
J Small Anim Pract ; 63(7): 542-549, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35137955

RESUMEN

OBJECTIVES: To describe the occurrence, management and outcome of proximal metaphyseal curvilinear tibial fractures in skeletally immature dogs. MATERIALS AND METHODS: A multi-centre retrospective review was conducted, searching for skeletally immature dogs presenting with proximal metaphyseal curvilinear tibial fractures between January 2009 and September 2020. Signalment, fracture description and case management data were retrieved. Outcome was assessed by retrospectively evaluating follow-up radiographs, hospital records and an owner questionnaire. RESULTS: Twenty-five dogs met the inclusion criteria. All but one fracture was a result of minimal trauma. Twenty fractures were managed with internal fixation, two with external fixation and three conservatively. All 25 fractures healed. Eight major complications occurred in seven of 25 (28%) dogs. Twelve minor complications occurred in 10 of 25 (40%) dogs. Owner questionnaire data were available for 12 of 25 dogs; 11 of 12 were reported as having full function and one of 12 as having acceptable function at the time of questioning (median 34.5 months following presentation). At final follow-up, either by clinical examination or owner questionnaire, full function was achieved in 22 of 25 patients and acceptable function in three of 25. CLINICAL SIGNIFICANCE: This study reported a series of proximal metaphyseal tibial fractures in skeletally immature dogs. The most common fixation method was internal fixation, which frequently resulted in full limb function at final follow-up. Owners reported outcome as fully functional in all dogs that underwent surgery at first presentation and had owner follow-up available, though positive outcomes may have been affected by participation bias.


Asunto(s)
Enfermedades de los Perros , Fracturas de la Tibia , Animales , Enfermedades de los Perros/diagnóstico por imagen , Enfermedades de los Perros/cirugía , Perros , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/veterinaria , Radiografía , Estudios Retrospectivos , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/veterinaria , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA