Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 210
Filtrar
1.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38781099

RESUMEN

AIMS: Cardioneuroablation (CNA) is a catheter-based intervention for recurrent vasovagal syncope (VVS) that consists in the modulation of the parasympathetic cardiac autonomic nervous system. This survey aims to provide a comprehensive overview of current CNA utilization in Europe. METHODS AND RESULTS: A total of 202 participants from 40 different countries replied to the survey. Half of the respondents have performed a CNA during the last 12 months, reflecting that it is considered a treatment option of a subset of patients. Seventy-one per cent of respondents adopt an approach targeting ganglionated plexuses (GPs) systematically in both the right atrium (RA) and left atrium (LA). The second most common strategy (16%) involves LA GP ablation only after no response following RA ablation. The procedural endpoint is frequently an increase in heart rate. Ganglionated plexus localization predominantly relies on an anatomical approach (90%) and electrogram analysis (59%). Less utilized methods include pre-procedural imaging (20%), high-frequency stimulation (17%), and spectral analysis (10%). Post-CNA, anticoagulation or antiplatelet therapy is prescribed, with only 11% of the respondents discharging patients without such medication. Cardioneuroablation is perceived as effective (80% of respondents) and safe (71% estimated <1% rate of procedure-related complications). Half view CNA emerging as a first-line therapy in the near future. CONCLUSION: This survey offers a snapshot of the current implementation of CNA in Europe. The results show high expectations for the future of CNA, but important heterogeneity exists regarding indications, procedural workflow, and endpoints of CNA. Ongoing efforts are essential to standardize procedural protocols and peri-procedural patient management.


Asunto(s)
Ablación por Catéter , Síncope Vasovagal , Humanos , Síncope Vasovagal/fisiopatología , Síncope Vasovagal/cirugía , Síncope Vasovagal/diagnóstico , Europa (Continente) , Ablación por Catéter/métodos , Flujo de Trabajo , Frecuencia Cardíaca , Resultado del Tratamiento , Encuestas de Atención de la Salud , Pautas de la Práctica en Medicina/tendencias , Técnicas Electrofisiológicas Cardíacas , Encuestas y Cuestionarios , Ganglios Autónomos/cirugía , Ganglios Autónomos/fisiopatología , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Recurrencia
3.
Anatol J Cardiol ; 25(7): 491-495, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-34236324

RESUMEN

OBJECTIVE: This study aimed to explore the safety and effectiveness of selective cardiac autonomic ganglion plexus (GP) ablation on patients with bradyarrhythmia. The heart is controlled by its own intrinsic and central autonomic nerves. Increased cardiac vagal tone leads to sinus node dysfunction and atrioventricular conduction disorders, resulting in bradyarrhythmia. Pacemaker implantation can relieve the symptoms of arrhythmia caused by bradycardia, but it is not easy for patients to accept a pacemaker implantation as a form of treatment. Therefore, more and more attention has been paid to cardiac vagus nerve ablation. METHODS: In this study, 20 patients who met the inclusion criteria of GP ablation in the First Affiliated Hospital of Xinjiang Medical University from November 2019 to June 2020 were enrolled. Biochemical and other related examinations along with electrophysiological examinations were conducted before ablation, and then cardiac GP ablation was performed. The patients were followed up 3 times at 3, 6, and 12 months after the operation. RESULTS: The minimum HR and mean HR were significantly increased after treatment with cardiac autonomic GP ablation (p<0.01). Moreover, the SDNN (Standard deviation of Normal-to-Normal Intervals) and RMSSD (Root mean square successive differences between successive R-R intervals) was significantly decreased after treatment with cardiac autonomic ganglion plexus ablation for 6 months and 12 months (p<0.01). CONCLUSION: Cardiac GP ablation is relatively simple and easy to implement in units that have performed radiofrequency ablation for bradyarrhythmias. This procedure can be performed without any new equipment. Some patients with bradycardia may not have a permanent pacemaker implantation and may go in for additional treatment options.


Asunto(s)
Bradicardia , Ablación por Catéter , Vías Autónomas , Ganglios Autónomos/cirugía , Frecuencia Cardíaca , Humanos , Síndrome del Seno Enfermo
7.
Pacing Clin Electrophysiol ; 43(5): 520-523, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32324285

RESUMEN

Pulmonary vein isolation (PVI) may cause vagal response during radiofrequency application or increase on heart rate after ablation. All those responses are related to inadvertent ablation effect on ganglionated plexi. In the present case, we aimed to explain why vagal response effects of PVI are not same in all cases.


Asunto(s)
Bradicardia/cirugía , Ablación por Catéter , Desnervación , Ganglios Autónomos/cirugía , Venas Pulmonares/cirugía , Nervio Vago/fisiopatología , Nervio Vago/cirugía , Adulto , Electrocardiografía , Mapeo Epicárdico , Femenino , Frecuencia Cardíaca , Humanos
8.
J Vis Exp ; (157)2020 03 07.
Artículo en Inglés | MEDLINE | ID: mdl-32202526

RESUMEN

The bilateral major pelvic ganglia (MPG; synonym, pelvic ganglia) are the primary source of postganglionic sympathetic and parasympathetic neurons innervating pelvic organs of rodents; the functionally equivalent structure in humans is the inferior hypogastric plexus. The major pelvic ganglia also provide the route by which lumbar and sacral sensory axons reach the pelvic organs. These complex, mixed ganglia can prove challenging to identify and dissect for further experimental study of normal autonomic mechanisms or to establish preclinical models of disease, injury or visceral pain. Here we describe a protocol to access and visualize these ganglia and their associated nerve tracts. We provide this protocol with schematics for both male and female rats, as the ganglion size and landmarks for identification differ between sexes. The protocol describes removal of the ganglion for in vitro studies, but this method can be integrated into a surgical recovery protocol for experimental interventions (e.g., nerve crush, nerve resection) or for mapping neuronal circuits (e.g., by microinjection of neural tracers). We also demonstrate the primary structures of the ganglion and its associated nerves immediately following dissection and following immunohistochemical staining.


Asunto(s)
Disección , Ganglios Autónomos/cirugía , Tejido Nervioso/cirugía , Pelvis/inervación , Puntos Anatómicos de Referencia , Animales , Axones/fisiología , Femenino , Ganglios Simpáticos/cirugía , Masculino , Ratas Sprague-Dawley
9.
J Cardiovasc Electrophysiol ; 30(12): 3039-3049, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31670479

RESUMEN

The effect of ganglion plexus (GP) ablation in addition to pulmonary veins isolation (PVI) for atrial fibrillation (AF) remained controversial between the catheter and surgical-based studies. Eleven studies (five randomized controlled trials and six nonrandomized studies) of 1750 patients were included in a meta-analysis to elucidate the incremental benefit of additional GP ablation in patients undergoing catheter or surgical ablation. Risk ratios were calculated for freedom from AF or AT recurrence after a single procedure. Additional GP ablation was associated with a better rhythm outcome for patients undergone catheter ablation but did not seem to increase freedom from AF/AT for surgical patients. Both paroxysmal and non-paroxysmal AF showed a positive outcome comparing additional GP ablation with PVI alone.


Asunto(s)
Fibrilación Atrial/cirugía , Desnervación Autonómica , Ablación por Catéter , Ganglios Autónomos/cirugía , Venas Pulmonares/cirugía , Potenciales de Acción , Adulto , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Desnervación Autonómica/efectos adversos , Ablación por Catéter/efectos adversos , Supervivencia sin Enfermedad , Femenino , Ganglios Autónomos/fisiopatología , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/inervación , Recurrencia , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
10.
J Am Heart Assoc ; 8(22): e013985, 2019 11 19.
Artículo en Inglés | MEDLINE | ID: mdl-31726961

RESUMEN

Background We previously reported the benefit of linear ablation from the superior vena cava to the right atrial septum (SVC-L) within a year after circumferential pulmonary vein isolation (CPVI) in patients with paroxysmal atrial fibrillation (AF). We explored the long-term effects of SVC-L and its potential related mechanisms. Methods and Results Among 2140 consecutive patients with AF ablation, we included 614 patients (73.3% male, aged 57.8±10.7 years, 13.7% with persistent AF) who did not undergo an extra-pulmonary vein left atrial ablation after propensity score matching; of those, 307 had additional SVC-L and 307 had CPVI alone. We evaluated the heart rate variability and computational modeling study to explore mechanisms. Although the procedure time was longer in the SVC-L group than the CPVI group (P<0.001), the complication rates did not differ (P=0.560). During 40.5±24.4 months of follow-up, the rhythm outcome was significantly better in the SVC-L group than the CPVI group (log rank, P<0.001). At 2-year follow-up of heart rate variability, a significantly higher mean heart rate (P=0.018) and a lower ratio of low/high-frequency components (P=0.011) were found with SVC-L than CPVI alone. In realistic in silico biatrial modeling, which reflected the electroanatomies of 10 patients, SVC-L significantly reduced biatrial dominant frequency compared with CPVI alone (P<0.001) and increased AF termination and defragmentation rates (P=0.033). Conclusions SVC-L ablation in addition to CPVI significantly improved the long-term rhythm outcome over 2 years after AF catheter ablation by mechanisms involving autonomic modulation and AF organization.


Asunto(s)
Fibrilación Atrial/cirugía , Tabique Interatrial/cirugía , Ablación por Catéter/métodos , Ganglios Autónomos/cirugía , Venas Pulmonares/cirugía , Vena Cava Superior/cirugía , Anciano , Sistema Nervioso Autónomo , Femenino , Corazón/inervación , Atrios Cardíacos , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Modelación Específica para el Paciente , Complicaciones Posoperatorias/epidemiología , Resultado del Tratamiento
13.
J Cardiovasc Electrophysiol ; 30(4): 607-615, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30680839

RESUMEN

BACKGROUND: Endocardial radiofrequency ablation of epicardial ganglionic plexus (GP) for atrial fibrillation (AF) is complicated by myocardial damage. OBJECTIVES: We hypothesized that an epicardial approach with a novel nitinol catheter system capable of causing irreversible electroporation (IRE) with direct current (DC) could selectively and permanently destroy GP without collateral myocardial injury. METHODS: Acute studies and medium-term terminal studies (mean survival, 1137 days) were performed with seven dogs. In the acute studies, DC was used to target epicardial GP within the transverse sinus, oblique sinus, vein of Marshall, and right periaortic space. Successful electroporation was defined as the presence of ablative lesions in the GP without collateral myocardial damage. A four-point integer system was used to classify histologic changes in tissue harvested from the ablation sites. Atrial effective refractory period (AERP) was measured during the acute and medium-term studies. RESULTS: For six dogs in the medium-term studies, the postablation period was uneventful without complications. Lesions were successfully created at 20 of 21 sites (95.2%) with more than minimal myocardial damage in one dog. An increase in AERP occurred in both atria during the acute studies but was maintained only in the right atrium at medium-term follow-up (5032 milliseconds). No dog had damage to the esophagus, adjacent great arteries, or pulmonary veins. CONCLUSIONS: This proof-of-concept study suggests that safe, effective, and selective epicardial ablation of GP can be performed with DC by IRE with minimal collateral myocardial damage.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Electroporación , Ganglios Autónomos/cirugía , Frecuencia Cardíaca , Pericardio/inervación , Potenciales de Acción , Animales , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Catéteres Cardíacos , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Modelos Animales de Enfermedad , Perros , Electroporación/instrumentación , Ganglios Autónomos/fisiopatología , Lesiones Cardíacas/etiología , Lesiones Cardíacas/patología , Masculino , Miocardio/patología , Prueba de Estudio Conceptual
14.
Virchows Arch ; 474(3): 395-400, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30607555

RESUMEN

Eosinophilic myenteric ganglionitis (EMG) is characterised by eosinophilic infiltration of the myenteric plexus. EMG has been rarely reported as a cause of chronic intestinal pseudo-obstruction (CIPO), and its histopathological features are not fully elucidated. We analysed seven patients with CIPO. Three of them were diagnosed with EMG and four patients were categorised as non-EMG. Clinicopathological features were similar in both groups. These features included subtle to mild lymphocytic infiltration at the myenteric ganglia/muscularis propria, loss of myenteric ganglions and interstitial cells of Cajal (ICC), and no significant findings in the mucosa. The exceptions were moderate to severe degree of eosinophilic infiltration at the myenteric ganglia/muscularis propria in EMG. Functional gastrointestinal obstruction may be associated with inflammatory cell infiltration at the myenteric ganglia/muscularis propria, leading to subsequent hypoganglionosis and deficiency of ICC in EMG. Pathologists and clinicians should be aware of this distinction during differential diagnosis of patients with CIPO.


Asunto(s)
Enfermedades del Sistema Nervioso Autónomo/complicaciones , Colon/inervación , Seudoobstrucción Colónica/etiología , Eosinofilia/complicaciones , Eosinófilos/patología , Ganglios Autónomos/patología , Plexo Mientérico/patología , Recto/inervación , Adulto , Anciano , Enfermedades del Sistema Nervioso Autónomo/patología , Enfermedades del Sistema Nervioso Autónomo/cirugía , Estudios de Casos y Controles , Enfermedad Crónica , Colon/cirugía , Seudoobstrucción Colónica/patología , Seudoobstrucción Colónica/cirugía , Eosinofilia/patología , Eosinofilia/cirugía , Femenino , Ganglios Autónomos/cirugía , Humanos , Inmunohistoquímica , Masculino , Persona de Mediana Edad , Plexo Mientérico/cirugía , Recto/cirugía , Resultado del Tratamiento
16.
Pacing Clin Electrophysiol ; 42(1): 13-19, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30426527

RESUMEN

BACKGROUND: Atrial ganglionated plexus (GP) ablation was proved to have therapeutic effects on vasovagal syncope. The study aimed to investigate whether selective ablation of only right anterior GP (ARGP) and right inferior GP (IRGP) was effective in a canine model of vasovagal syncope. METHODS: Seventeen mongrel dogs were divided into control (N = 10) and ablation group (N = 7). Bilateral thoracotomy was performed at the fourth intercostal space and ARGP and IRGP were ablated in the ablation group. A bolus of veratridine (15 ug/kg) was injected into the left atrium to induce vasovagal reflex. Surface electrocardiogram and blood pressure (BP) were continuously monitored. Heart rate (HR) variability was calculated to represent cardiac autonomic tone. RESULTS: Veratridine injection induced vasovagal reflex in all dogs. HR decreased from 149 ± 17 to 89 ± 33 beats/min (P < 0.001) in the control group, while in the ablation group HR decreased from 141 ± 35 to 125 ± 34 beats/min (P = 0.032). The postveratridine HR in the ablation group was significantly higher than that in the control group (P = 0.045). A significantly less intense HR decrease was observed in the ablation group compared with control (-17 ± 16 vs -61 ± 34 beats/min, P = 0.006). Significant BP decreases were induced in both the groups (all P < 0.01), while no evident differences in postveratridine BP and the extent of BP decreases were found between the groups. HR variability revealed significant decrease in cardiac vagal tone after ablation [high-frequency power, 0.50 (0.17-1.05) vs 6.28 (0.68-8.99) ms2 , P = 0.005]. CONCLUSIONS: Selective ablation of ARGP + IRGP weakened cardiac parasympathetic control and significantly attenuated the cardioinhibitory response in an animal model of vasovagal reflex. This ablation strategy might be effective for vasovagal syncope with evident cardioinhibitory response.


Asunto(s)
Ablación por Catéter/métodos , Ganglios Autónomos/cirugía , Atrios Cardíacos/cirugía , Sistema de Conducción Cardíaco/fisiopatología , Síncope Vasovagal/cirugía , Animales , Modelos Animales de Enfermedad , Perros , Electrocardiografía , Ganglios Autónomos/fisiopatología , Atrios Cardíacos/fisiopatología , Síncope Vasovagal/fisiopatología , Toracotomía , Veratridina
18.
J Thorac Cardiovasc Surg ; 155(3): 972-980, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29089093

RESUMEN

OBJECTIVE: We evaluated health-related quality of life at 12 months after thoracoscopic surgical ablation in patients enrolled in the Atrial Fibrillation Ablation and Autonomic Modulation via Thoracoscopic Surgery study. The Atrial Fibrillation Ablation and Autonomic Modulation via Thoracoscopic Surgery study assessed the efficacy and safety of ganglion plexus ablation in patients with symptomatic advanced atrial fibrillation undergoing thoracoscopic surgical ablation. METHODS: Patients (n = 240) underwent thoracoscopic pulmonary vein isolation with additional ablation lines in patients with persistent atrial fibrillation. Subjects were randomized to additional ganglion plexus ablation or control. Short Form 36 quality of life questionnaires were collected at baseline and at 6 and 12 months of follow-up. RESULTS: A total of 201 patients were eligible for quality of life analysis (age 59 ± 8 years, 72% were men, 68% had an enlarged left atrium, 57% had persistent atrial fibrillation). Patients improved in physical and mental health at 6 months (both P < .01) and 12 months (both P < .01) relative to baseline, with no difference between the ganglion plexus (n = 101) and control (n = 100) groups. Short Form 36 subscores in patients with 1 or no atrial fibrillation recurrences were similar to those in the general Dutch population after 12 months. Patients with multiple atrial fibrillation recurrences (30%) improved in mental (P < .01), but not physical health, and 6 of 8 Short Form 36 subscales remained below those of the general Dutch population. Patients with irreversible, but not with reversible procedural complications had persistently diminished quality of life scores at 12 months. CONCLUSIONS: Thoracoscopic surgery for advanced atrial fibrillation results in improvement in quality of life, regardless of additional ganglion plexus ablation. Quality of life in patients with no or 1 atrial fibrillation recurrence increased to the level of the general Dutch population, whereas in patients with multiple atrial fibrillation recurrences quality of life remained lower. Irreversible but not reversible procedural complications were associated with persistently lower quality of life.


Asunto(s)
Fibrilación Atrial/cirugía , Desnervación Autonómica/métodos , Ablación por Catéter/métodos , Ganglios Autónomos/cirugía , Venas Pulmonares/cirugía , Calidad de Vida , Toracoscopía/métodos , Adulto , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Desnervación Autonómica/efectos adversos , Ablación por Catéter/efectos adversos , Electrocardiografía , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Países Bajos , Venas Pulmonares/fisiopatología , Recurrencia , Encuestas y Cuestionarios , Toracoscopía/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
19.
BMC Cardiovasc Disord ; 17(1): 292, 2017 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-29233092

RESUMEN

BACKGROUND: Ganglionated plexuses (GP) are terminal parts of cardiac autonomous nervous system (ANS). Radiofrequency ablation (RFA) for atrial fibrillation (AF) possibly affects GP. Changes in heart rate variability (HRV) after RFA can reflect ANS modulation. METHODS: Epicardial RFA of GP on the left atrium (LA) was performed under the general anesthesia in 15 mature Romanov sheep. HRV was used to assess the alterations in autonomic regulation of the heart. A 24 - hour ECG monitoring was performed before the ablation, 2 days after it and at each of the 12 following months. Ablation sites were evaluated histologically. RESULTS: There was an instant change in HRV parameters after the ablation. A standard deviation of all intervals between normal QRS (SDNN), a square root of the mean of the squared differences between successive normal QRS intervals (RMSSD) along with HRV triangular index (TI), low frequency (LF) power and high frequency (HF) power decreased, while LF/HF ratio increased. Both the SDNN, LF power and the HF power changes persisted throughout the 12 - month follow - up. Significant decrease in RMSSD persisted only for 3 months, HRV TI for 6 months and increase in LF/HF ratio for 7 months of the follow - up. Afterwards these three parameters were not different from the preprocedural values. CONCLUSIONS: Epicardial RFA of GP's on the ovine left atrium has lasting effect on the main HRV parameters (SDNN, HF power and LF power). The normalization of RMSSD, HRV TI and LF/HF suggests that HRV after epicardial RFA of GPs on the left atrium might restore over time.


Asunto(s)
Función del Atrio Izquierdo , Desnervación Autonómica/métodos , Ablación por Catéter , Ganglios Autónomos/cirugía , Atrios Cardíacos/inervación , Frecuencia Cardíaca , Animales , Electrocardiografía Ambulatoria , Femenino , Ganglios Autónomos/fisiopatología , Masculino , Oveja Doméstica , Factores de Tiempo
20.
J Interv Card Electrophysiol ; 50(3): 253-260, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28887742

RESUMEN

PURPOSE: Adjunctive ganglionated plexi (GP) ablation may improve success rates for treatment of atrial fibrillation (AF) when combined with pulmonary vein (PV) isolation. Existing meta-analyses on GP ablation have included observational studies and have not incorporated more recent randomized clinical trial data. Moreover, the impact of AF subtype (paroxysmal vs. persistent) on outcomes of GP ablation has not been well established. METHODS: We performed a meta-analysis of randomized controlled trials (RCTs) comparing GP ablation + pulmonary vein (PV) isolation versus PV isolation alone according to the subtype of AF. The primary endpoint was freedom from sustained AF or atrial tachyarrhythmia (AT) after a single procedure. RESULTS: Across four RCTs, 718 patients (358 and 360 that underwent GP ablation + PV isolation [intervention] vs. PV isolation alone [control], respectively) were included in the study. Mean left atrial size and left ventricular ejection fraction were 45.7 mm and 54.8%, respectively. Among paroxysmal AF patients, GP ablation was linked to significantly higher freedom from AT/AF (75.8 vs. 60.0% for the intervention vs. control arms respectively; OR [95% CI]: 2.22 [1.36-3.61], P = 0.001). Among persistent AF patients, GP ablation was associated with a non-significant trend towards higher rates of freedom from AT/AF (54.7 vs. 43.3% for the intervention vs. control arms respectively; OR [95% CI]: 1.55 [0.96-2.52], P = 0.08). In all cases, heterogeneity was found to be low (I 2 of 32% or lower). CONCLUSIONS: Compared to PV isolation alone, GP ablation + PV isolation is associated with better outcomes in patients with paroxysmal AF and without significant structural heart disease.


Asunto(s)
Fibrilación Atrial/cirugía , Desnervación Autonómica/métodos , Ablación por Catéter/métodos , Ganglios Autónomos/cirugía , Venas Pulmonares/cirugía , Taquicardia Paroxística/cirugía , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/mortalidad , Desnervación Autonómica/mortalidad , Ablación por Catéter/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Ensayos Clínicos Controlados Aleatorios como Asunto , Recurrencia , Medición de Riesgo , Análisis de Supervivencia , Taquicardia Paroxística/diagnóstico por imagen , Taquicardia Paroxística/mortalidad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...