Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41.854
Filtrar
1.
Sci Rep ; 14(1): 10504, 2024 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-38714788

RESUMEN

We compared cardiovascular parameters obtained with the Mobil-O-Graph and functional capacity assessed by the Duke Activity Status Index (DASI) before and after Heart Transplantation (HT) and also compared the cardiovascular parameters and the functional capacity of candidates for HT with a control group. Peripheral and central vascular pressures increased after surgery. Similar results were observed in cardiac output and pulse wave velocity. The significant increase in left ventricular ejection fraction (LVEF) postoperatively was not followed by an increase in the functional capacity. 24 candidates for HT and 24 controls were also compared. Functional capacity was significantly lower in the HT candidates compared to controls. Stroke volume, systolic, diastolic, and pulse pressure measured peripherally and centrally were lower in the HT candidates when compared to controls. Despite the significant increase in peripheral and central blood pressures after surgery, the patients were normotensive. The 143.85% increase in LVEF in the postoperative period was not able to positively affect functional capacity. Furthermore, the lower values of LVEF, systolic volume, central and peripheral arterial pressures in the candidates for HT are consistent with the characteristics signs of advanced heart failure, negatively impacting functional capacity, as observed by the lower DASI score.


Asunto(s)
Trasplante de Corazón , Análisis de la Onda del Pulso , Volumen Sistólico , Humanos , Trasplante de Corazón/métodos , Masculino , Proyectos Piloto , Femenino , Persona de Mediana Edad , Volumen Sistólico/fisiología , Adulto , Presión Sanguínea/fisiología , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/cirugía , Función Ventricular Izquierda/fisiología , Aorta/cirugía , Aorta/fisiopatología , Gasto Cardíaco/fisiología
2.
Curr Opin Crit Care ; 30(3): 251-259, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38690954

RESUMEN

PURPOSE OF REVIEW: To describe current and near future developments and applications of CO2 kinetics in clinical respiratory and cardiovascular monitoring. RECENT FINDINGS: In the last years, we have witnessed a renewed interest in CO2 kinetics in relation with a better understanding of volumetric capnography and its derived parameters. This together with technological advances and improved measurement systems have expanded the monitoring potential of CO2 kinetics including breath by breath continuous end-expiratory lung volume and continuous noninvasive cardiac output. Dead space has slowly been gaining relevance in clinical monitoring and prognostic evaluation. Easy to measure dead space surrogates such as the ventilatory ratio have demonstrated a strong prognostic value in patients with acute respiratory failure. SUMMARY: The kinetics of carbon dioxide describe many relevant physiological processes. The clinical introduction of new ways of assessing respiratory and circulatory efficiency based on advanced analysis of CO2 kinetics are paving the road to a long-desired goal in clinical monitoring of critically ill patients: the integration of respiratory and circulatory monitoring during mechanical ventilation.


Asunto(s)
Capnografía , Dióxido de Carbono , Humanos , Dióxido de Carbono/análisis , Capnografía/métodos , Monitoreo Fisiológico/métodos , Respiración Artificial/métodos , Cinética , Gasto Cardíaco/fisiología , Biomarcadores , Espacio Muerto Respiratorio/fisiología
3.
J Physiol ; 602(10): 2227-2251, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38690610

RESUMEN

Passive whole-body hyperthermia increases limb blood flow and cardiac output ( Q ̇ $\dot Q$ ), but the interplay between peripheral and central thermo-haemodynamic mechanisms remains unclear. Here we tested the hypothesis that local hyperthermia-induced alterations in peripheral blood flow and blood kinetic energy modulate flow to the heart and Q ̇ $\dot Q$ . Body temperatures, regional (leg, arm, head) and systemic haemodynamics, and left ventricular (LV) volumes and functions were assessed in eight healthy males during: (1) 3 h control (normothermic condition); (2) 3 h of single-leg heating; (3) 3 h of two-leg heating; and (4) 2.5 h of whole-body heating. Leg, forearm, and extracranial blood flow increased in close association with local rises in temperature while brain perfusion remained unchanged. Increases in blood velocity with small to no changes in the conduit artery diameter underpinned the augmented limb and extracranial perfusion. In all heating conditions, Q ̇ $\dot Q$ increased in association with proportional elevations in systemic vascular conductance, related to enhanced blood flow, blood velocity, vascular conductance and kinetic energy in the limbs and head (all R2 ≥ 0.803; P < 0.001), but not in the brain. LV systolic (end-systolic elastance and twist) and diastolic functional profiles (untwisting rate), pulmonary ventilation and systemic aerobic metabolism were only altered in whole-body heating. These findings substantiate the idea that local hyperthermia-induced selective alterations in peripheral blood flow modulate the magnitude of flow to the heart and Q ̇ $\dot Q$ through changes in blood velocity and kinetic energy. Localised heat-activated events in the peripheral circulation therefore affect the human heart's output. KEY POINTS: Local and whole-body hyperthermia increases limb and systemic perfusion, but the underlying peripheral and central heat-sensitive mechanisms are not fully established. Here we investigated the regional (leg, arm and head) and systemic haemodynamics (cardiac output: Q ̇ $\dot Q$ ) during passive single-leg, two-leg and whole-body hyperthermia to determine the contribution of peripheral and central thermosensitive factors in the control of human circulation. Single-leg, two-leg, and whole-body hyperthermia induced graded increases in leg blood flow and Q ̇ $\dot Q$ . Brain blood flow, however, remained unchanged in all conditions. Ventilation, extracranial blood flow and cardiac systolic and diastolic functions only increased during whole-body hyperthermia. The augmented Q ̇ $\dot Q$ with hyperthermia was tightly related to increased limb and head blood velocity, flow and kinetic energy. The findings indicate that local thermosensitive mechanisms modulate regional blood velocity, flow and kinetic energy, thereby controlling the magnitude of flow to the heart and thus the coupling of peripheral and central circulation during hyperthermia.


Asunto(s)
Gasto Cardíaco , Hipertermia , Humanos , Masculino , Adulto , Hipertermia/fisiopatología , Gasto Cardíaco/fisiología , Velocidad del Flujo Sanguíneo/fisiología , Flujo Sanguíneo Regional/fisiología , Fiebre/fisiopatología , Adulto Joven , Calor , Hemodinámica
4.
PLoS One ; 19(5): e0302793, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38739601

RESUMEN

BACKGROUND: In cardiology, cardiac output (CO) is an important parameter for assessing cardiac function. While invasive thermodilution procedures are the gold standard for CO assessment, transthoracic Doppler echocardiography (TTE) has become the established method for routine CO assessment in daily clinical practice. However, a demand persists for non-invasive approaches, including oscillometric pulse wave analysis (PWA), to enhance the accuracy of CO estimation, reduce complications associated with invasive procedures, and facilitate its application in non-intensive care settings. Here, we aimed to compare the TTE and oscillometric PWA algorithm Antares for a non-invasive estimation of CO. METHODS: Non-invasive CO data obtained by two-dimensional TTE were compared with those from an oscillometric blood pressure device (custo med GmbH, Ottobrunn, Germany) using the integrated algorithm Antares (Redwave Medical GmbH, Jena, Germany). In total, 59 patients undergoing elective cardiac catheterization for clinical reasons (71±10 years old, 76% males) were included. Agreement between both CO measures were assessed by Bland-Altman analysis, Student's t-test, and Pearson correlations. RESULTS: The mean difference in CO was 0.04 ± 1.03 l/min (95% confidence interval for the mean difference: -0.23 to 0.30 l/min) for the overall group, with lower and upper limits of agreement at -1.98 and 2.05 l/min, respectively. There was no statistically significant difference in means between both CO measures (P = 0.785). Statistically significant correlations between TTE and Antares CO were observed in the entire cohort (r = 0.705, P<0.001) as well as in female (r = 0.802, P<0.001) and male patients (r = 0.669, P<0.001). CONCLUSIONS: The oscillometric PWA algorithm Antares and established TTE for a non-invasive estimation of CO are highly correlated in male and female patients, with no statistically significant difference between both approaches. Future validation studies of the Antares CO are necessary before a clinical application can be considered.


Asunto(s)
Algoritmos , Gasto Cardíaco , Ecocardiografía Doppler , Análisis de la Onda del Pulso , Humanos , Masculino , Femenino , Gasto Cardíaco/fisiología , Anciano , Análisis de la Onda del Pulso/métodos , Ecocardiografía Doppler/métodos , Persona de Mediana Edad , Anciano de 80 o más Años , Oscilometría/métodos
5.
Acta Biochim Pol ; 71: 12377, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38721303

RESUMEN

Background: Goal-directed fluid therapy, as a crucial component of accelerated rehabilitation after surgery, plays a significant role in expediting postoperative recovery and enhancing the prognosis of major surgical procedures. Methods: In line with this, the present study aimed to investigate the impact of target-oriented fluid therapy on volume management during ERAS protocols specifically for gastrointestinal surgery. Patients undergoing gastrointestinal surgery at our hospital between October 2019 and May 2021 were selected as the sample population for this research. Results: 41 cases of gastrointestinal surgery patients were collected from our hospital over 3 recent years. Compared with T1, MAP levels were significantly increased from T2 to T5; cardiac output (CO) was significantly decreased from T2 to T3, and significantly increased from T4 to T5; and SV level was significantly increased from T3 to T5. Compared with T2, HR and cardiac index (CI) were significantly elevated at T1 and at T3-T5. Compared with T3, SVV was significantly decreased at T1, T2, T4, and T5; CO and stroke volume (SV) levels were increased significantly at T4 and T5. In this study, pressor drugs were taken for 23 days, PACU residence time was 40.22 ± 12.79 min, time to get out of bed was 12.41 ± 3.97 h, exhaust and defecation time was 18.11 ± 7.52 h, and length of postoperative hospital stay was 4.47 ± 1.98 days. The average HAMA score was 9.11 ± 2.37, CRP levels were 10.54 ± 3.38 mg/L, adrenaline levels were 132.87 ± 8.97 ng/L, and cortisol levels were 119.72 ± 4.08 ng/L. Prealbumin levels were 141.98 ± 10.99 mg/L at 3 d after surgery, and 164.17 ± 15.84 mg/L on the day of discharge. Lymphocyte count was 1.22 ± 0.18 (109/L) at 3 d after surgery, and 1.47 ± 0.17 (109/L) on the day of discharge. Serum albumin levels were 30.51 ± 2.28 (g/L) at 3 d after surgery, and 33.52 ± 2.07 (g/L) on the day of discharge. Conclusion: Goal-directed fluid therapy (GDFT) under the concept of Enhanced Recovery After Surgery (ERAS) is helpful in volume management during radical resection of colorectal tumors, with good postoperative recovery. Attention should be paid to the influence of pneumoperitoneum and intraoperative posture on GDFT parameters.


Asunto(s)
Procedimientos Quirúrgicos del Sistema Digestivo , Fluidoterapia , Humanos , Fluidoterapia/métodos , Masculino , Femenino , Persona de Mediana Edad , Procedimientos Quirúrgicos del Sistema Digestivo/métodos , Procedimientos Quirúrgicos del Sistema Digestivo/rehabilitación , Anciano , Recuperación Mejorada Después de la Cirugía , Volumen Sistólico , Tiempo de Internación/estadística & datos numéricos , Gasto Cardíaco , Adulto
6.
Artículo en Inglés | MEDLINE | ID: mdl-38684395

RESUMEN

PURPOSE: Goal-directed perfusion (GDP) refers to individualized goal-directed therapy using comprehensive monitoring and optimizing the delivery of oxygen during cardiopulmonary bypass (CPB). This study aims to determine whether the intraoperative GDP protocol method has better outcomes compared to conventional methods. METHODS: We searched the PubMed, Central, and Scopus databases up to October 12, 2023. We primarily examined the GDP protocol in adult cardiac surgery, using CPB with oxygen delivery index (DO2I) and cardiac index (CI) as the main parameters. RESULTS: In all, 1128 participants from seven studies were included in our analysis. The results showed significant differences in the duration of intensive care unit (ICU) stays (p = 0.01), with a mean difference of -0.33 (-0.59 to 0.07), and hospital length of stay (LOS) (p = 0.0002), with a mean difference of -0.84 (-1.29 to -0.39). There was also a notable reduction in postoperative complications (p <0.00001), odds ratio (OR) of 0.43 (0.32-0.60). However, there was no significant decrease in mortality rate (p = 0.54), OR of 0.77 (0.34-1.77). CONCLUSION: Postoperative acute kidney injury and ICU and hospital LOS are significantly reduced when GDP protocols with indicators of flow management, oxygen delivery index, and CI are used in intraoperative cardiac surgery using CPB.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Puente Cardiopulmonar , Tiempo de Internación , Humanos , Puente Cardiopulmonar/efectos adversos , Resultado del Tratamiento , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/mortalidad , Oxígeno/sangre , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Masculino , Anciano , Persona de Mediana Edad , Cuidados Intraoperatorios , Femenino , Factores de Tiempo , Monitoreo Intraoperatorio/métodos , Valor Predictivo de las Pruebas , Toma de Decisiones Clínicas , Gasto Cardíaco
8.
J Appl Physiol (1985) ; 136(5): 1276-1283, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38602000

RESUMEN

In patients with chronic obstructive pulmonary disease (COPD), pulmonary vascular dysfunction and destruction are observable before the onset of detectable emphysema, but it is unknown whether this is associated with central hypovolemia. We investigated if patients with COPD have reduced pulmonary blood volume (PBV) evaluated by 82Rb-positron emission tomography (PET) at rest and during adenosine-induced hyperemia. This single-center retrospective cohort study assessed 6,301 82Rb-PET myocardial perfusion imaging (MPI) examinations performed over a 6-yr period. We compared 77 patients with COPD with 44 healthy kidney donors (controls). Cardiac output ([Formula: see text]) and mean 82Rb bolus transit time (MBTT) were used to calculate PBV. [Formula: see text] was similar at rest (COPD: 3,649 ± 120 mL vs. control: 3,891 ± 160 mL, P = 0.368) but lower in patients with COPD compared with controls during adenosine infusion (COPD: 5,432 ± 124 mL vs. control: 6,185 ± 161 mL, P < 0.050). MBTT was shorter in patients with COPD compared with controls at rest (COPD: 8.7 ± 0.28 s vs. control: 11.4 ± 0.37 s, P < 0.001) and during adenosine infusion (COPD: 9.2 ± 0.28 s vs. control: 10.2 ± 0.37 s, P < 0.014). PBV was lower in patients with COPD, even after adjustment for body surface area, sex, and age at rest [COPD: 530 (29) mL vs. 708 (38) mL, P < 0.001] and during adenosine infusion [COPD: 826 (29) mL vs. 1,044 (38) mL, P < 0.001]. In conclusion, patients with COPD show evidence of central hypovolemia, but it remains to be determined whether this has any diagnostic or prognostic impact.NEW & NOTEWORTHY The present study demonstrated that patients with chronic obstructive pulmonary disease (COPD) exhibit central hypovolemia compared with healthy controls. Pulmonary blood volume may thus be a relevant physiological and/or clinical outcome measure in future COPD studies.


Asunto(s)
Volumen Sanguíneo , Tomografía de Emisión de Positrones , Enfermedad Pulmonar Obstructiva Crónica , Humanos , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Anciano , Volumen Sanguíneo/fisiología , Tomografía de Emisión de Positrones/métodos , Pulmón/fisiopatología , Pulmón/diagnóstico por imagen , Radioisótopos de Rubidio , Imagen de Perfusión Miocárdica/métodos , Adenosina/administración & dosificación , Gasto Cardíaco/fisiología
10.
Artículo en Inglés | MEDLINE | ID: mdl-38673361

RESUMEN

Adults who have had an amputation face barriers to having an active lifestyle which attenuates cardiorespiratory fitness. Prior studies in amputees typically involve treadmill walking or arm ergometry, yet physiological responses to bilateral leg cycling are less understood. This study assessed the hemodynamic and metabolic responses to moderate and vigorous cycle ergometry in men who have had a transtibial amputation (TTA). Five men who had had a unilateral TTA (age = 39 ± 15 yr) and six controls (CONs) without an amputation (age = 31 ± 11 yr) performed two 20 min bouts of cycling differing in intensity. Cardiac output (CO), stroke volume (SV), and oxygen consumption (VO2) were measured during moderate intensity continuous exercise (MICE) and high intensity interval exercise (HIIE) using thoracic impedance and indirect calorimetry. In response to MICE and HIIE, the HR and VO2 levels were similar (p > 0.05) between groups. Stroke volume and CO were higher (p < 0.05) in the CONs, which was attributed to their higher body mass. In men with TTAs, HIIE elicited a peak HR = 88%HRmax and substantial blood lactate accumulation, representing vigorous exercise intensity. No adverse events were exhibited in the men with TTAs. The men with TTAs show similar responses to MICE and HIIE versus the CONs.


Asunto(s)
Amputación Quirúrgica , Hemodinámica , Consumo de Oxígeno , Masculino , Humanos , Adulto , Persona de Mediana Edad , Prueba de Esfuerzo , Adulto Joven , Tibia/cirugía , Ciclismo/fisiología , Ejercicio Físico/fisiología , Gasto Cardíaco/fisiología
12.
J Am Heart Assoc ; 13(9): e033744, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38686853

RESUMEN

BACKGROUND: The heart can metabolize the microbiota-derived short-chain fatty acid butyrate. Butyrate may have beneficial effects in heart failure, but the underlying mechanisms are unknown. We tested the hypothesis that butyrate elevates cardiac output by mechanisms involving direct stimulation of cardiac contractility and vasorelaxation in rats. METHODS AND RESULTS: We examined the effects of butyrate on (1) in vivo hemodynamics using parallel echocardiographic and invasive blood pressure measurements, (2) isolated perfused hearts in Langendorff systems under physiological conditions and after ischemia and reperfusion, and (3) isolated coronary arteries mounted in isometric wire myographs. We tested Na-butyrate added to injection solutions or physiological buffers and compared its effects with equimolar doses of NaCl. Butyrate at plasma concentrations of 0.56 mM increased cardiac output by 48.8±14.9%, stroke volume by 38.5±12.1%, and left ventricular ejection fraction by 39.6±6.2%, and lowered systemic vascular resistance by 33.5±6.4% without affecting blood pressure or heart rate in vivo. In the range between 0.1 and 5 mM, butyrate increased left ventricular systolic pressure by up to 23.7±3.4% in isolated perfused hearts and by 9.4±2.9% following ischemia and reperfusion, while reducing myocardial infarct size by 81.7±16.9%. Butyrate relaxed isolated coronary septal arteries concentration dependently with an EC50=0.57 mM (95% CI, 0.23-1.44). CONCLUSIONS: We conclude that butyrate elevates cardiac output through mechanisms involving increased cardiac contractility and vasorelaxation. This effect of butyrate was not associated with adverse myocardial injury in damaged hearts exposed to ischemia and reperfusion.


Asunto(s)
Butiratos , Cardiotónicos , Contracción Miocárdica , Vasodilatación , Vasodilatadores , Función Ventricular Izquierda , Animales , Masculino , Contracción Miocárdica/efectos de los fármacos , Función Ventricular Izquierda/efectos de los fármacos , Vasodilatación/efectos de los fármacos , Cardiotónicos/farmacología , Butiratos/farmacología , Vasodilatadores/farmacología , Preparación de Corazón Aislado , Ratas , Daño por Reperfusión Miocárdica/fisiopatología , Daño por Reperfusión Miocárdica/prevención & control , Daño por Reperfusión Miocárdica/metabolismo , Gasto Cardíaco/efectos de los fármacos , Volumen Sistólico/efectos de los fármacos , Ratas Wistar , Vasos Coronarios/efectos de los fármacos , Vasos Coronarios/fisiopatología , Relación Dosis-Respuesta a Droga , Modelos Animales de Enfermedad , Ratas Sprague-Dawley
13.
Physiol Rep ; 12(9): e16027, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38684421

RESUMEN

Resistance breathing may restore cardiac output (CO) and cerebral blood flow (CBF) during hypovolemia. We assessed CBF and cerebral autoregulation (CA) during tilt, resistance breathing, and paced breathing in 10 healthy subjects. Blood velocities in the internal carotid artery (ICA), middle cerebral arteries (MCA, four subjects), and aorta were measured by Doppler ultrasound in 30° and 60° semi-recumbent positions. ICA blood flow and CO were calculated. Arterial blood pressure (ABP, Finometer), and end-tidal CO2 (ETCO2) were recorded. ICA blood flow response was assessed by mixed-models regression analysis. The synchronization index (SI) for the variable pairs ABP-ICA blood velocity, ABP-MCA velocities in 0.005-0.08 Hz frequency interval was calculated as a measure of CA. Passive tilting from 30° to 60° resulted in 12% decrease in CO (p = 0.001); ICA blood flow tended to fall (p = 0.04); Resistance breathing restored CO and ICA blood flow despite a 10% ETCO2 drop. ETCO2 and CO contributed to ICA blood flow variance (adjusted R2: 0.9, p < 0.0001). The median SI was low (<0.2) indicating intact CA, confirmed by surrogate date testing. The peak SI was transiently elevated during resistance breathing in the 60° position. Resistance breathing may transiently reduce CA efficiency. Paced breathing did not restore CO or ICA blood flow.


Asunto(s)
Circulación Cerebrovascular , Homeostasis , Humanos , Masculino , Circulación Cerebrovascular/fisiología , Homeostasis/fisiología , Proyectos Piloto , Adulto , Femenino , Velocidad del Flujo Sanguíneo/fisiología , Arteria Cerebral Media/fisiología , Arteria Cerebral Media/diagnóstico por imagen , Gasto Cardíaco/fisiología , Voluntarios Sanos , Arteria Carótida Interna/fisiología , Arteria Carótida Interna/diagnóstico por imagen , Presión Sanguínea/fisiología
14.
Comput Methods Programs Biomed ; 250: 108191, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38677079

RESUMEN

BACKGROUND AND OBJECTIVE: Enhanced external counterpulsation (EECP) is a mechanically assisted circulation technique widely used in the rehabilitation and management of ischemic cardiovascular diseases. It contributes to cardiovascular functions by regulating the afterload of ventricle to improve hemodynamic effects, including increased diastolic blood pressure at aortic root, increased cardiac output and enhanced blood perfusion to multiple organs including coronary circulation. However, the effects of EECP on the coupling of the ventricle and the arterial system, termed ventricular-arterial coupling (VAC), remain elusive. We aimed to investigate the acute effect of EECP on the dynamic interaction between the left ventricle and its afterload of the arterial system from the perspective of ventricular output work. METHODS: A neural network assisted optimization algorithm was proposed to identify the ordinary differential equation (ODE) relation between aortic root blood pressure and flow rate. Based on the optimized order of ODE, a lumped parameter model (LPM) under EECP was developed taking into consideration of the simultaneous action of cardiac and EECP pressure sources. The ventricular output work, in terms of aortic pressure and flow rate cooperated with the LPM, was used to characterize the VAC of ventricle and its afterload. The VAC subjected to the principle of minimal ventricular output work was validated by solving the Euler-Poisson equation of cost function, ultimately determining the waveforms of aortic pressure and flow rate. RESULTS: A third-order ODE can precisely describe the hemodynamic relationship between aortic pressure and flow rate. An optimized dual-source LPM with three energy-storage elements has been constructed, showing the potential in probing VAC under EECP. The LPM simulation results demonstrated that the VAC in terms of aortic pressure and flow rate yielded to the minimal ventricular output work under different EECP pressures. CONCLUSIONS: The ventricular-arterial coupling under EECP is subjected to the minimal ventricular output work, which can serve as a criterion for determining aortic pressure and flow rate. This study provides insight for the understanding of VAC and has the potential in characterizing the performance of the ventricular and arterial system under EECP.


Asunto(s)
Algoritmos , Contrapulsación , Ventrículos Cardíacos , Hemodinámica , Modelos Cardiovasculares , Humanos , Contrapulsación/métodos , Gasto Cardíaco , Arterias/fisiología , Presión Sanguínea , Simulación por Computador , Aorta/fisiología , Redes Neurales de la Computación
15.
Eur Radiol Exp ; 8(1): 51, 2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38517595

RESUMEN

BACKGROUND: To validate pulmonary computed tomography (CT) perfusion in a porcine model by invasive monitoring of cardiac output (CO) using thermodilution method. METHODS: Animals were studied at a single center, using a Swan-Ganz catheter for invasive CO monitoring as a reference. Fifteen pigs were included. Contrast-enhanced CT perfusion of the descending aorta and right and left pulmonary artery was performed. For variation purposes, a balloon catheter was inserted to block the contralateral pulmonary vascular bed; additionally, two increased CO settings were created by intravenous administration of catecholamines. Finally, stepwise capillary occlusion was performed by intrapulmonary arterial injection of 75-µm microspheres in four stages. A semiautomatic selection of AFs and a recirculation-aware tracer-kinetics model to extract the first-pass of AFs, estimating blood flow with the Stewart-Hamilton method, was implemented. Linear mixed models (LMM) were developed to calibrate blood flow calculations accounting with individual- and cohort-level effects. RESULTS: Nine of 15 pigs had complete datasets. Strong correlations were observed between calibrated pulmonary (0.73, 95% confidence interval [CI] 0.6-0.82) and aortic blood flow measurements (0.82, 95% CI, 0.73-0.88) and the reference as well as agreements (± 2.24 L/min and ± 1.86 L/min, respectively) comparable to the state of the art, on a relatively wide range of right ventricle-CO measurements. CONCLUSIONS: CT perfusion validly measures CO using LMMs at both individual and cohort levels, as demonstrated by referencing the invasive CO. RELEVANCE STATEMENT: Possible clinical applications of CT perfusion for measuring CO could be in acute pulmonary thromboembolism or to assess right ventricular function to show impairment or mismatch to the left ventricle. KEY POINTS: • CT perfusion measures flow in vessels. • CT perfusion measures cumulative cardiac output in the aorta and pulmonary vessels. • CT perfusion validly measures CO using LMMs at both individual and cohort levels, as demonstrated by using the invasive CO as a reference standard.


Asunto(s)
Cateterismo de Swan-Ganz , Arteria Pulmonar , Humanos , Porcinos , Animales , Gasto Cardíaco/fisiología , Arteria Pulmonar/diagnóstico por imagen , Cateterismo de Swan-Ganz/métodos , Perfusión , Tomografía Computarizada por Rayos X
16.
Int J Mol Sci ; 25(6)2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38542290

RESUMEN

Anaphylactic shock (AS) is the most severe form of acute systemic hypersensitivity reaction. Although epinephrine can restore patients' hemodynamics, it might also be harmful, supporting the need for adjuvant treatment. We therefore investigated whether NButGT, enhancing O-GlcNAcylation and showing beneficial effects in acute heart failure might improve AS therapy. Ovalbumin-sensitized rats were randomly allocated to six groups: control (CON), shock (AS), shock treated with NButGT alone before (AS+pre-Nbut) or after (AS+post-Nbut) AS onset, shock treated with epinephrine alone (AS+EPI) and shock group treated with combination of epinephrine and NButGT (AS+EPI+preNBut). Induction of shock was performed with an intravenous (IV) ovalbumin. Cardiac protein and cycling enzymes O-GlcNAcylation levels, mean arterial pressure (MAP), heart rate, cardiac output (CO), left ventricle shortening fraction (LVSF), mitochondrial respiration, and lactatemia were evaluated using Western blotting experiments, invasive arterial monitoring, echocardiography, mitochondrial oximetry and arterial blood samples. AS decreased MAP (-77%, p < 0.001), CO (-90%, p < 0.001) and LVSF (-30%, p < 0.05). Epinephrine improved these parameters and, in particular, rats did not die in 15 min. But, cardiac mitochondrial respiration remained impaired (complexes I + II -29%, p < 0.05 and II -40%, p < 0.001) with hyperlactatemia. NButGT pretreatment (AS+pre-Nbut) efficiently increased cardiac O-GlcNAcylation level as compared to the AS+post-Nbut group. Compared to epinephrine alone, the adjunction of NButGT significantly improved CO, LVSF and mitochondrial respiration. MAP was not significantly increased but lactatemia decreased more markedly. Pretreatment with NButGT increases O-GlcNAcylation of cardiac proteins and has an additive effect on epinephrine, improving cardiac output and mitochondrial respiration and decreasing blood lactate levels. This new therapy might be useful when the risk of AS cannot be avoided.


Asunto(s)
Anafilaxia , Compuestos Bicíclicos Heterocíclicos con Puentes , Humanos , Ratas , Animales , Anafilaxia/tratamiento farmacológico , Ovalbúmina/farmacología , Epinefrina/farmacología , Gasto Cardíaco , Hemodinámica , Respiración
17.
J Physiol Sci ; 74(1): 21, 2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38555424

RESUMEN

Mean circulatory filling pressure, venous return curve, and Guyton's graphical analysis are basic concepts in cardiovascular physiology. However, some medical students may not know how to view and interpret or understand them adequately. To deepen students' understanding of the graphical analysis, in place of having to perform live animal experiments, we developed an interactive cardiovascular simulator, as a self-learning tool, as a web application. The minimum closed-loop model consisted of a ventricle, an artery, resistance, and a vein, excluding venous resistance. The simulator consists of three modules: setting (parameters and simulation modes), calculation, and presentation. In the setting module, the user can interactively customize model parameters, compliances, resistance, Emax of the ventricular contractility, total blood volume, and unstressed volume. The hemodynamics are calculated in three phases: filling (late diastole), ejection (systole), and flow (early diastole). In response to the user's settings, the simulator graphically presents the hemodynamics: the pressure-volume relations of the artery, vein, and ventricle, the venous return curves, and the stroke volume curves. The mean filling pressure is calculated at approximately 7 mmHg at the initial setting. The venous return curves, linear and concave, are dependent on the venous compliance. The hemodynamic equilibrium point is marked on the crossing point of venous return curve and the stroke volume curve. Users can interactively do discovery learning, and try and confirm their interests and get their questions answered about hemodynamic concepts by using the simulator.


Asunto(s)
Hemodinámica , Venas , Animales , Humanos , Venas/fisiología , Volumen Sistólico , Presión Sanguínea/fisiología , Gasto Cardíaco/fisiología
18.
Physiol Rep ; 12(6): e15979, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38490814

RESUMEN

Postural orthostatic tachycardia syndrome (POTS) is characterized by an excessive heart rate (HR) response upon standing and symptoms indicative of inadequate cerebral perfusion. We tested the hypothesis that during lower body negative pressure (LBNP), individuals with POTS would have larger decreases in cardiac and cerebrovascular function measured using magnetic resonance (MR) imaging. Eleven patients with POTS and 10 healthy controls were studied at rest and during 20 min of -25 mmHg LBNP. Biventricular volumes, stroke volume (SV), cardiac output (Qc), and HR were determined by cardiac MR. Cerebral oxygen uptake (VO2 ) in the superior sagittal sinus was calculated from cerebral blood flow (CBF; MR phase contrast), venous O2 saturation (SvO2 ; susceptometry-based oximetry), and arterial O2 saturation (pulse oximeter). Regional cerebral perfusion was determined using arterial spin labelling. HR increased in response to LBNP (p < 0.001) with no group differences (HC: +9 ± 8 bpm; POTS: +13 ± 11 bpm; p = 0.35). Biventricular volumes, SV, and Qc decreased during LBNP (p < 0.001). CBF and SvO2 decreased with LBNP (p = 0.01 and 0.03, respectively) but not cerebral VO2 (effect of LBNP: p = 0.28; HC: -0.2 ± 3.7 mL/min; POTS: +1.1 ± 2.0 mL/min; p = 0.33 between groups). Regional cerebral perfusion decreased during LBNP (p < 0.001) but was not different between groups. These data suggest patients with POTS have preserved cardiac and cerebrovascular function.


Asunto(s)
Síndrome de Taquicardia Postural Ortostática , Humanos , Síndrome de Taquicardia Postural Ortostática/diagnóstico por imagen , Presión Negativa de la Región Corporal Inferior , Gasto Cardíaco/fisiología , Circulación Cerebrovascular/fisiología , Frecuencia Cardíaca/fisiología , Presión Sanguínea/fisiología
19.
Am J Physiol Heart Circ Physiol ; 326(5): H1131-H1137, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38456848

RESUMEN

A significant number of pregnancies occur at advanced maternal age (>35 yr), which is a risk factor for pregnancy complications. Healthy pregnancies require massive hemodynamic adaptations, including an increased blood volume and cardiac output. There is growing evidence that these cardiovascular adaptations are impaired with age, however, little is known about maternal cardiac function with advanced age. We hypothesized that cardiac adaptations to pregnancy are impaired with advanced maternal age. Younger (4 mo; ∼early reproductive maturity in humans) and aged (9 mo; ∼35 yr in humans) pregnant Sprague-Dawley rats were assessed and compared with age-matched nonpregnant controls. Two-dimensional echocardiographic images were obtained (ultrasound biomicroscopy; under anesthesia) on gestational day 19 (term = 22 days) and compared with age-matched nonpregnant rats (n = 7-9/group). Left ventricular structure and function were assessed using short-axis images and transmitral Doppler signals. During systole, left ventricular anterior wall thickness increased with age in the nonpregnant rats, but there was no age-related difference between the pregnant groups. There were no significant pregnancy-associated differences in left ventricular wall thickness. Calculated left ventricular mass increased with age in nonpregnant rats and increased with pregnancy only in young rats. Compared with young pregnant rats, the aortic ejection time of aged pregnant rats was greater and Tei index was lower. Overall, the greater aortic ejection time and lower Tei index with age in pregnant rats suggest mildly altered cardiac adaptations to pregnancy with advanced maternal age, which may contribute to adverse outcomes in advanced maternal age pregnancies.NEW & NOTEWORTHY We demonstrated that even before the age of reproductive senescence, rats show signs of age-related alterations in cardiac structure that suggests increased cardiac work. Our data also demonstrate, using an in vivo echocardiographic approach, that advanced maternal age in a rat model is associated with altered cardiac function and structure relative to younger pregnant controls.


Asunto(s)
Ecocardiografía , Corazón , Embarazo , Femenino , Humanos , Ratas , Animales , Edad Materna , Ratas Sprague-Dawley , Corazón/diagnóstico por imagen , Gasto Cardíaco
20.
Med Eng Phys ; 125: 104126, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38508803

RESUMEN

BACKGROUND: Increasingly, computational fluid dynamics (CFD) is helping explore the impact of variables like: cannula design/size/position/flow rate and patient physiology on venovenous (VV) extracorporeal membrane oxygenation (ECMO). Here we use a CFD model to determine what role cardiac output (CO) plays and to analyse return cannula dynamics. METHODS: Using a patient-averaged model of the right atrium and venae cava, we virtually inserted a 19Fr return cannula and a 25Fr drainage cannula. Running large eddy simulations, we assessed cardiac output at: 3.5-6.5 L/min and ECMO flow rate at: 2-6 L/min. We analysed recirculation fraction (Rf), time-averaged wall shear stress (TAWSS), pressure, velocity, and turbulent kinetic energy (TKE) and extracorporeal flow fraction (EFF = ECMO flow rate/CO). RESULTS: Increased ECMO flow rate and decreased CO (high EFF) led to increased Rf (R = 0.98, log fit). Negative pressures developed in the venae cavae at low CO and high ECMO flow (high CR). Mean return cannula TAWSS was >10 Pa for all ECMO flow rates, with majority of the flow exiting the tip (94.0-95.8 %). CONCLUSIONS: Our results underpin the strong impact of CO on VV ECMO. A simple metric like EFF, once supported by clinical data, might help predict Rf for a patient at a given ECMO flow rate. The return cannula imparts high shear stresses on the blood, largely a result of the internal diameter.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Humanos , Oxigenación por Membrana Extracorpórea/métodos , Cánula , Gasto Cardíaco , Atrios Cardíacos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...