Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Clin Biochem ; 112: 6-10, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36535386

RESUMEN

BACKGROUND: Urine drug testing (UDT) monitors prescription compliance and/or drug abuse. However, interpretation of UDT results obtained by liquid chromatography-tandem mass spectrometry (LC-MS-MS) can be complicated by the presence of drug impurities that are detected by highly sensitive methods. Hydrocodone is a drug impurity that can be found as high as 1% in oxycodone pills. OBJECTIVES: We evaluated the frequency and concentration of hydrocodone and its metabolite, hydromorphone, in patients taking oxycodone to check if the ratio of hydrocodone or hydromorphone to oxycodone could distinguish between oxycodone only use from those consuming additional opiates. DESIGN & METHODS: We correlated LC-MS/MS results with medication records of 319 patients with positive oxycodone results over 7 months (4/2021-11/2021). RESULTS: Fifteen of 319 patients with positive oxycodone results were taking oxycodone only. For these 15 patients, the mean ratio of hydrocodone to oxycodone was 0.57% (range 0.05%-3.35%), and the mean ratio of hydromorphone to oxycodone was 0.81% (range 0.18-3.51%). CONCLUSIONS: Hydrocodone and/or hydromorphone are detectable in patients taking only oxycodone and can likely be identified as an impurity if their calculated ratio to oxycodone is <1 %. Further validation of the ratios in a larger sample size is recommended.


Asunto(s)
Hidrocodona , Trastornos Relacionados con Opioides , Humanos , Hidrocodona/análisis , Hidromorfona/análisis , Oxicodona , Analgésicos Opioides , Cromatografía Liquida/métodos , Oximorfona , Espectrometría de Masas en Tándem/métodos
2.
Environ Toxicol Chem ; 41(11): 2658-2666, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35920352

RESUMEN

Active pharmaceutical ingredient (API) contamination of water sources, including opioid contamination, has become more common in recent years. Although drinking water-treatment plants help mitigate API infiltration, API contamination remains in some drinking water sources. Therefore, the ability to detect APIs at ultratrace concentrations is vital to ensure safe drinking water. A method for the ultratrace determination of fentanyl, hydrocodone, and codeine in drinking water via direct injection and high-performance liquid-chromatography tandem mass spectrometry (HPLC-MS/MS) was developed and validated. Drinking water samples (10 ml) are simply syringe-filtered and then analyzed by HPLC-MS/MS. A wide linear range (0.25-100 ng/L) and ultratrace limits of detection (80, 150, and 500 pg/L for fentanyl, hydrocodone, and codeine, respectively) were features of the method. The method produced excellent aggregate accuracies of 90%-115% and precisions of ≤11% for the three analytes tested. This method was used to test drinking water samples from 53 US locations, with hydrocodone and codeine detected in approximately 40% of the samples tested at concentrations between 0.3 and 20 ng/L. Codeine was detected at higher concentrations than hydrocodone (up to 7.3 times) for each sample containing these APIs. Fentanyl was not detected in any field drinking water sample. The detection of opioids in a large fraction of the US drinking water samples tested is cause for concern, and these levels should continue to be monitored to ensure that they do not become a threat to human health. Environ Toxicol Chem 2022;41:2658-2666. © 2022 SETAC.


Asunto(s)
Agua Potable , Humanos , Agua Potable/química , Cromatografía Líquida de Alta Presión , Analgésicos Opioides/análisis , Espectrometría de Masas en Tándem/métodos , Hidrocodona/análisis , Cromatografía Liquida/métodos , Prevalencia , Codeína/análisis , Preparaciones Farmacéuticas
3.
J Forensic Sci ; 64(1): 144-148, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29684941

RESUMEN

Heroin and fentanyl are the overwhelming and increasing cause of opioid deaths in Milwaukee County, Wisconsin. We reviewed all drug and opioid deaths from 2013 to 2017 to delineate the specific opioid drugs involved and changes in their incidence. From 2013 to 2017, 980 deaths were due to opioids, rising from 184 in 2013 to 337 in 2017. In 2017, opioid deaths exceeded combined non-natural deaths from homicide and suicide. Illicit heroin and fentanyl/analogs caused 84% of opioid deaths and 80% of drug deaths, with no increase in deaths due to oral prescription drugs such as oxycodone and hydrocodone. Any approach to decreasing this dramatic increase in opioid deaths should first focus on interdicting the supply and cheap availability of these illicit opioids. Fentanyl and its analogs represent the most deadly opioids and the greatest threat to human life in our population.


Asunto(s)
Analgésicos Opioides/envenenamiento , Fentanilo/envenenamiento , Heroína/envenenamiento , Drogas Ilícitas/envenenamiento , Trastornos Relacionados con Opioides/mortalidad , Analgésicos Opioides/análisis , Buprenorfina/análisis , Buprenorfina/envenenamiento , Médicos Forenses , Fentanilo/análisis , Heroína/análisis , Humanos , Hidrocodona/análisis , Hidrocodona/envenenamiento , Drogas Ilícitas/análisis , Incidencia , Metadona/análisis , Metadona/envenenamiento , Oxicodona/análisis , Oxicodona/envenenamiento , Trastornos Relacionados con Sustancias/mortalidad , Wisconsin/epidemiología
4.
Drug Alcohol Depend ; 193: 183-191, 2018 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-30391868

RESUMEN

BACKGROUND: Drug testing is recommended as part of comprehensive monitoring for medication-assisted treatment. Alternative matrices including oral fluid offer a number of advantages when compared with conventional urine testing but are not as well characterized. This study aims to compare positivity rates of drugs and drug classes in oral fluid and urine as a measure of the clinical utility of oral fluid in the evaluation and treatment of patients with opioid use disorders. METHODS: A retrospective review of paired oral fluid and urine test results from Millennium Health's laboratory database was performed for 2746 patients with reported prescriptions for buprenorphine products used in the treatment of opioid dependence. Specimens were tested using quantitative LC-MS/MS for 34 medications, metabolites and illicit drugs. RESULTS: A number of medications and illicit drugs were detected at comparable or higher rates in oral fluid vs. urine such as cocaine (15.7% vs. 7.9%), opiates (13.4% vs. 10.0%), oxycodone (8.6% vs. 3.7%), hydrocodone (3.0% vs. 1.2%) and others. Lower detection rates were observed in oral fluid vs. urine for benzodiazepines (6.6% vs. 8.7%), cannabinoids (15.5% vs. 19.5%), oxymorphone (1.8% vs. 3.1%) and hydromorphone (0.8% vs. 4.5%). CONCLUSIONS: Clinicians may find oral fluid advantageous for detection of specific drugs and medications in certain clinical situations. Understanding the relative differences between urine and oral fluid can help clinicians carefully select tests best suited for detection in their respective matrix. To our knowledge, this is the largest inter-matrix patient comparison study using paired collections and direct to definitive testing.


Asunto(s)
Buprenorfina/uso terapéutico , Drogas Ilícitas/análisis , Antagonistas de Narcóticos/uso terapéutico , Trastornos Relacionados con Opioides/tratamiento farmacológico , Detección de Abuso de Sustancias/métodos , Cannabinoides/análisis , Cromatografía Liquida , Humanos , Hidrocodona/análisis , Hidromorfona/análisis , Drogas Ilícitas/orina , Oxicodona/análisis , Oximorfona/análisis , Estudios Retrospectivos , Saliva/química , Espectrometría de Masas en Tándem
5.
J Anal Toxicol ; 42(6): 392-399, 2018 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-29554298

RESUMEN

Recent advances in analytical capabilities allowing for the identification and quantification of drugs and metabolites in small volumes at low concentrations have made oral fluid a viable matrix for drug testing. Oral fluid is an attractive matrix option due to its relative ease of collection, reduced privacy concerns for observed collections and difficulty to adulterate. The work presented here details the development and validation of a liquid chromatography tandem mass spectrometry (LC-MS-MS) method for the quantification of codeine, morphine, 6-acetylmorphine, hydrocodone, hydromorphone, oxycodone and oxymorphone in neat oral fluid. The calibration range is 0.4-150 ng/mL for 6-acetylmorphine and 1.5-350 ng/mL for all other analytes. Within-run and between-run precision were <5% for all analytes except for hydrocodone, which had 6.2 %CV between runs. Matrix effects, while evident, could be controlled using matrix-matched controls and calibrators with deuterated internal standards. The assay was developed in accordance with the proposed mandatory guidelines for opioid confirmation in federally regulated workplace drug testing. The use of neat oral fluid, as opposed to a collection device, enables collection of a single sample that can be split into separate specimens.


Asunto(s)
Analgésicos Opioides/análisis , Cromatografía Liquida , Codeína/análisis , Hidrocodona/análisis , Hidromorfona/análisis , Derivados de la Morfina/análisis , Morfina/análisis , Trastornos Relacionados con Opioides/diagnóstico , Oxicodona/análisis , Oximorfona/análisis , Saliva/química , Espectrometría de Masa por Ionización de Electrospray , Detección de Abuso de Sustancias/métodos , Espectrometría de Masas en Tándem , Calibración , Cromatografía Liquida/normas , Humanos , Trastornos Relacionados con Opioides/metabolismo , Valor Predictivo de las Pruebas , Estándares de Referencia , Reproducibilidad de los Resultados , Espectrometría de Masa por Ionización de Electrospray/normas , Detección de Abuso de Sustancias/normas , Espectrometría de Masas en Tándem/normas
6.
Ther Drug Monit ; 39(1): 88-90, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-28081042

RESUMEN

A retrospective analysis of oral fluid drug testing results using LC-MS/MS was performed to determine the prevalence rates in oral fluid for codeine (COD) and 3 COD metabolites-morphine (MOR), norhydrocodone (NHC), and hydrocodone (HCOD). Oral fluid samples were collected using Quantisal oral fluid collection device (Immunalysis Inc.) and submitted to Millennium Health, LLC for the routine drug analysis by LC-MS/MS. Consistent with previously published literature, COD was the primary analyte detected in oral fluid after the use of COD. In COD-positive samples, HCOD, MOR, and NHC were detected at rates of 68.4%, 18.4%, and 6.3%, respectively. Concentration ranges of these analytes were 1.0 to >2000 ng/mL for COD, 1.0-20.2 ng/mL for MOR, 1.0-740.0 ng/mL for HCOD, and 2.1-47.5 ng/mL for NHC. In contrast to urine, where HCOD is typically detected as a minor metabolite of COD, HCOD was the most commonly detected metabolite in oral fluid in samples testing positive for COD with reported prescriptions for COD. This observation suggests that care should be taken when interpreting HCOD positives in oral fluid results, and that the use of COD should be considered as one possible explanation for HCOD positives.


Asunto(s)
Analgésicos Opioides/farmacocinética , Cromatografía Liquida/métodos , Codeína/farmacocinética , Espectrometría de Masas en Tándem/métodos , Analgésicos Opioides/administración & dosificación , Codeína/administración & dosificación , Humanos , Hidrocodona/análogos & derivados , Hidrocodona/análisis , Hidrocodona/metabolismo , Morfina/análisis , Morfina/metabolismo , Estudios Retrospectivos , Detección de Abuso de Sustancias/métodos
7.
Bioanalysis ; 8(9): 953-64, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-27067523

RESUMEN

BACKGROUND: Identification of external contamination is a challenge in hair analysis. This study investigates metabolite ratios of hydromorphone to morphine and hydrocodone to codeine as indicators to distinguish contamination from heroin use provided that hydromorphone/hydrocodone intake is excluded. RESULTS: Hair samples after external contamination with street heroin proved to be negative for hydromorphone/hydrocodone. Hair samples from individuals with suspected street heroin use/contamination or opiate medication were analyzed for 6-monoacetylmorphine, morphine, acetylcodeine, codeine, hydromorphone and hydrocodone, and metabolite ratios of hydromorphone to morphine and hydrocodone to codeine were assessed. Hair samples from individuals with medicinal heroin/morphine/codeine use displayed significantly higher metabolite ratios than those with suspected street heroin use/contamination. CONCLUSION: Hydromorphone/hydrocodone are solely formed during body passage. Thus, metabolite ratios can be used to distinguish morphine/heroin use from external contamination.


Asunto(s)
Analgésicos Opioides/análisis , Cabello/química , Heroína/análisis , Hidrocodona/análisis , Hidromorfona/análisis , Alcaloides Opiáceos/análisis , Detección de Abuso de Sustancias/métodos , Cromatografía Liquida/métodos , Femenino , Dependencia de Heroína/diagnóstico , Humanos , Masculino , Morfina/análisis , Derivados de la Morfina/análisis , Espectrometría de Masas en Tándem/métodos
8.
Bull Environ Contam Toxicol ; 95(2): 139-44, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26067702

RESUMEN

Drug disposal programs have been seen as a remedy to the concern of environmental contamination resulting from pharmaceutical disposal down the toilet or sink; however a thorough review of peer-reviewed literature and publicly available information on these programs indicates limited research has been conducted to validate the effectiveness of these programs at reducing pharmaceuticals in the environment. The purpose of this research was to determine if drug disposal programs could actually reduce pharmaceutical residues in the environment. The concentration of hydrocodone in wastewater effluent released from a wastewater treatment plant in Denton, Texas was monitored before and after a take back program called Denton Drug Disposal Day (D4). Data collected and analyzed suggests D4 events were successful in contributing to a reduction of pharmaceutical loading to the environment; however there was insufficient evidence to demonstrate that D4 events were exclusively responsible for these improvements.


Asunto(s)
Analgésicos Opioides/análisis , Hidrocodona/análisis , Eliminación de Residuos Líquidos/métodos , Aguas Residuales/química , Contaminantes Químicos del Agua/análisis , Texas
9.
Forensic Sci Int ; 247: 36-40, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25541075

RESUMEN

Postmortem changes can alter the concentration of drugs in the vascular compartment as compared with concentrations originally present at the time of death. Numerous drugs have been reported to increase due to postmortem redistribution (PMR). The potential for PMR of hydrocodone, a therapeutic opioid analgesic used to manage pain, is of particular interest due to its wide use. Hydrocodone concentrations in 39 peripheral blood, central blood, and liver specimens were compared. Dihydrocodeine (DHC), a commonly encountered hydrocodone metabolite, was present in 61% of the cases with an average concentration that was 29% of the hydrocodone value. Central blood to peripheral blood hydrocodone ratios were well correlated (R(2)=0.965) with an average (±S.D.) of 1.3 (±0.35) and a median of 1.2. The liver to peripheral blood (L/P) hydrocodone ratio was also well correlated (R(2)=0.915) with an average (±S.D.) of 3.4 (±1.7) L/kg and a median of 3.0 L/kg. This low L/P ratio suggests that hydrocodone is unlikely to undergo substantial PMR changes.


Asunto(s)
Analgésicos Opioides/análisis , Analgésicos Opioides/farmacocinética , Hidrocodona/análisis , Hidrocodona/farmacocinética , Hígado/química , Cambios Post Mortem , Cromatografía de Gases , Codeína/análogos & derivados , Codeína/análisis , Toxicología Forense , Humanos , Extracción en Fase Sólida , Distribución Tisular
10.
J Opioid Manag ; 10(3): 177-86, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24944068

RESUMEN

OBJECTIVE: Hydrocodone undergoes metabolism via cytochrome P450 (CYP) 3A4 (N-demethylation) to norhydrocodone and via CYP2D6 (O-demethylation) to hydromorphone. Hydrocodone, hydromorphone, and norhydrocodone are excreted in urine and secreted in saliva. The goal was to characterize hydrocodone and its metabolites in oral fluid specimens of a pain population and compare to urine specimens. DESIGN: This retrospective analysis included more than 8,500 oral fluid specimens and more than 250,000 urine specimens collected between March and June 2012 that were sent to Millennium Laboratories (San Diego, CA) and analyzed for hydrocodone, hydromorphone, and norhydrocodone using liquid chromatography-tandem mass spectrometry. Statistical analyses and linear regressions were conducted using Microsoft Excel® 2010 and OriginPro v8.6. RESULTS: The median oral fluid concentrations of hydrocodone and norhydrocodone were 122 and 7.7 ng/mL, respectively. However, the oral fluid concentrations of hydromorphone were below detection in many specimens (<1 ng/mL). The positive detection rate of parent drug and metabolites in oral fluid (17-31 percent detection rates) was much lower than in urine (63-75 percent detection rates). The geometric median metabolic ratio (MR) of norhydrocodone to hydrocodone was 0.07 in oral fluid and 1.2 in urine. The observed hydrocodone oral fluid concentrations were approximately 10-fold greater than previously reported plasma concentrations. CONCLUSION: Oral fluid had a much lower norhydrocodone to hydrocodone MR compared to urine. Reference ranges for oral fluid drug concentrations should not be extrapolated from plasma ranges. The observed ranges of secreted hydrocodone and metabolite concentrations in oral fluid should help determine reference ranges for medication monitoring.


Asunto(s)
Analgésicos Opioides/metabolismo , Hidrocodona/metabolismo , Dolor/tratamiento farmacológico , Saliva/metabolismo , Monitoreo de Drogas , Humanos , Hidrocodona/análogos & derivados , Hidrocodona/análisis , Hidrocodona/orina , Hidromorfona/análisis , Hidromorfona/orina , Valores de Referencia , Estudios Retrospectivos
11.
J Anal Toxicol ; 36(2): 106-11, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22337779

RESUMEN

Our objective was to develop a "dilute and shoot" liquid chromatography-tandem mass spectrometry confirmatory procedure that uses full scan product ion spectra to identify drugs that are present above cutoff values as determined by isotope dilution relative to a deuterium-labeled internal standard. Deuterium-labeled internal standards are added to urine which is then diluted prior to analysis. Full scan product ion spectra were obtained in the data-dependent mode using a linear ion trap (ABI 4000 Qtrap). Identification was based on a purity fit of greater than 70. Ninety-seven urine specimens were analyzed by the method described, and results were compared to values obtained from a reference laboratory using selected reaction monitoring (SRM). The ion trap provided about 30-fold increase in signal-to-noise ratio as compared with the same instrument operated in a traditional full scan product ion mode. The assays were linear to at least 10 times the cutoff. Selecting appropriate triggers for obtaining full scan product ion spectra minimized space charging for specimens that contained high concentrations of drugs. There was 100% concordance between the full scan identification and the SRM results for identification of amphetamine, methamphetamine, benzoylecgonine, morphine, codeine, hydrocodone, and hydromorphone. The ability to "dilute and shoot" reduces the turnaround time for results. The data acquired with SRM and full scan product ion spectra provide accurate quantification and a high degree of specificity.


Asunto(s)
Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Cocaína/análogos & derivados , Cocaína/análisis , Cocaína/orina , Humanos , Hidrocodona/análisis , Hidrocodona/orina , Hidromorfona/análisis , Hidromorfona/orina , Iones/aislamiento & purificación , Metanfetamina/análisis , Metanfetamina/orina , Reproducibilidad de los Resultados , Relación Señal-Ruido , Detección de Abuso de Sustancias/métodos
12.
Clin Toxicol (Phila) ; 50(1): 1-14, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22148986

RESUMEN

Over the last few decades, the rate of breastfeeding has increased steadily in the developed countries of the world. During this time, opioid use in the general population has steadily increased as well. Despite this, clinicians remain unclear whether opioid use is safe during breastfeeding. While the vast majority of medications used during breastfeeding occur without incident, case reports and studies have reported possible opioid toxicity in breast-fed infants. Multiple enzymes are involved in the metabolism of opioids. CYP2D6 catabolizes O-demethylation of codeine, tramadol, oxycodone, and hydrocodone to more potent metabolites. CYP3A4 inactivates methadone, meperidine, and buprenorphine. Glucoronide conjugation by the UGT enzyme family inactivates morphine and hydromorphone. Genetic polymorphisms and interfering medications affect the maternal metabolism, which in turn determines the exposure and risk to the breast-fed neonate. We review the production of breast milk, the transfer of xenobiotics from blood to milk, the characteristics that alter xenobiotic breast-milk concentrations, and we review the evidence of specific common opioids and infant toxicity. The short-term maternal use of prescription opioids is usually safe and infrequently presents a hazard to the newborn.


Asunto(s)
Analgésicos Opioides/efectos adversos , Lactancia Materna/efectos adversos , Factores de Edad , Analgésicos Opioides/análisis , Analgésicos Opioides/farmacocinética , Buprenorfina/efectos adversos , Buprenorfina/análisis , Buprenorfina/farmacocinética , Codeína/efectos adversos , Codeína/análisis , Codeína/farmacocinética , Femenino , Humanos , Hidrocodona/efectos adversos , Hidrocodona/análisis , Hidrocodona/farmacocinética , Lactante , Recién Nacido , Meperidina/efectos adversos , Meperidina/análisis , Meperidina/farmacocinética , Metadona/efectos adversos , Metadona/análisis , Metadona/farmacocinética , Leche Humana/química , Morfina/efectos adversos , Morfina/análisis , Morfina/farmacocinética , Oxicodona/efectos adversos , Oxicodona/análisis , Oxicodona/farmacocinética
13.
Obstet Gynecol ; 117(3): 611-617, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21343764

RESUMEN

OBJECTIVE: To estimate the extent of passage of hydrocodone and its active metabolite, hydromorphone, into breast milk. METHODS: This is a pharmacokinetic study of 30 postpartum women receiving hydrocodone bitartrate for postpartum pain in the inpatient setting. Mothers donated timed breast milk samples for the analysis of hydrocodone and hydromorphone. RESULTS: Fully breastfed neonates received 1.6% (range 0.2%-9%) of the maternal weight-adjusted hydrocodone bitartrate dosage. When combined with hydromorphone, the total median opiate dosage from breast milk is 0.7% of a therapeutic dosage for older infants. Most mothers excreted little to no hydromorphone into breast milk. CONCLUSION: Standard postpartum dosages of hydrocodone bitartrate appear to be acceptable to use in women nursing newborns. Prolonged use of high dosages is not advisable.


Asunto(s)
Analgésicos Opioides/farmacocinética , Hidrocodona/farmacocinética , Hidromorfona/farmacocinética , Leche Humana/química , Acetaminofén/uso terapéutico , Adolescente , Adulto , Analgésicos no Narcóticos/uso terapéutico , Analgésicos Opioides/análisis , Analgésicos Opioides/uso terapéutico , Femenino , Humanos , Hidrocodona/análisis , Hidrocodona/uso terapéutico , Hidromorfona/análisis , Hidromorfona/uso terapéutico , Dolor/tratamiento farmacológico , Periodo Posparto , Embarazo , Adulto Joven
14.
Yao Xue Xue Bao ; 46(12): 1501-6, 2011 Dec.
Artículo en Chino | MEDLINE | ID: mdl-22375426

RESUMEN

The paper reports the establishment of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) for simultaneous analysis of 11 opiates in hair samples, and the study of presence of opiates in the hair of active heroin addicts. About 20 mg of decontaminated and pulverized hair sample was hydrolyzed with buffer solution for 30 min, in the presence of morphine-d3 and acetylmorphine-d6 used as internal standards, and then extracted with the mixture of dichlormethane and isopropanol, separated by the Allure PFP propyl column with a mobile phase consisting of acetonitrile and 20 mmol L(-1) ammonium acetate buffer, and then analyzed by LC-MS/MS. Multiple reaction monitoring (MRM) mode was used to analyze 11 opiates. Eleven opiates showed a fairly good linearity over the corresponding range (r > 0.996 0). The detection limits were less than 0.05 ng mg(-1). The recoveries were between 47.2% and 110%, and the deviations of intra- and inter-day precision were less than 14%. Heroin, acetylmorphine, morphine, codeine, acetylcodeine and hydrocodone were detected in hair samples of 21 herion addicts. The developed method shows high sensitivity and selectivity, and is suitable for the simultaneous analysis of 11 opiates in hair samples and identify legal and illegal use of opiates.


Asunto(s)
Analgésicos Opioides/análisis , Cabello/química , Detección de Abuso de Sustancias/métodos , Cromatografía Liquida/métodos , Codeína/análogos & derivados , Codeína/análisis , Heroína/análisis , Humanos , Hidrocodona/análisis , Límite de Detección , Morfina/análisis , Derivados de la Morfina/análisis , Sensibilidad y Especificidad , Espectrometría de Masas en Tándem/métodos
15.
J Forensic Leg Med ; 15(6): 395-7, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18586212

RESUMEN

We encountered a decedent with an unexpected glioblastoma multiforme. A 61-year-old retired African-American woman was found dead in her home, fully clothed in her bathtub, with a pillow under her head. At autopsy, the brain showed a glioblastoma multiforme. Toxicology showed elevated hydrocodone, propoxyphene, acetaminophen, and positive paroxetine. The presence of a brain tumor likely caused a severe headache. The use of her medications could have indicated a reaction to the escalating pain of the brain trauma, and overuse could be consistent with escalating pain or loss of rational thought processes. The present case is interesting in that it had evidence of behavioral dysfunction that could be related to the brain tumor, and death arising from the glioblastoma multiforme (cerebral hemorrhage and edema) with concurrent multiple drug intoxication.


Asunto(s)
Neoplasias Encefálicas/patología , Glioblastoma/patología , Cefaleas Secundarias/tratamiento farmacológico , Trastornos Mentales/etiología , Automedicación/efectos adversos , Acetaminofén/administración & dosificación , Acetaminofén/efectos adversos , Acetaminofén/análisis , Analgésicos no Narcóticos/administración & dosificación , Analgésicos no Narcóticos/efectos adversos , Analgésicos no Narcóticos/análisis , Analgésicos Opioides/administración & dosificación , Analgésicos Opioides/efectos adversos , Analgésicos Opioides/análisis , Edema Encefálico/etiología , Edema Encefálico/patología , Neoplasias Encefálicas/complicaciones , Dextropropoxifeno/administración & dosificación , Dextropropoxifeno/efectos adversos , Dextropropoxifeno/análogos & derivados , Dextropropoxifeno/análisis , Femenino , Patologia Forense , Toxicología Forense , Glioblastoma/complicaciones , Cefaleas Secundarias/etiología , Humanos , Hidrocodona/administración & dosificación , Hidrocodona/efectos adversos , Hidrocodona/análisis , Hemorragias Intracraneales/etiología , Hemorragias Intracraneales/patología , Persona de Mediana Edad , Paroxetina/administración & dosificación , Paroxetina/efectos adversos , Paroxetina/análisis , Inhibidores Selectivos de la Recaptación de Serotonina/administración & dosificación , Inhibidores Selectivos de la Recaptación de Serotonina/efectos adversos , Inhibidores Selectivos de la Recaptación de Serotonina/análisis , Cuerpo Vítreo/química
16.
J Anal Toxicol ; 31(1): 1-14, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17389078

RESUMEN

A liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for simultaneous analysis of six major opiates in urine, serum, plasma, whole blood, and meconium is described. The six opiates included are codeine, morphine, hydrocodone, hydromorphone, oxycodone, and 6-acetylmorphine (6-AM). The method was compared to an in-house gas chromatography (GC)-MS method and an LC-MS-MS method performed by another laboratory. The sample preparation time was decreased by eliminating the glucuronide hydrolysis and derivatization required for GC-MS analysis, as well as by adapting the solid-phase extraction to elute directly into autosampler vials. These improvements illustrate the advantages of an LC-MS-MS method over a GC-MS method for opiates. The structural similarity of these six opiates and others in the opiate class causes a high potential for interference and false-positive results. Twelve opiate analogues and metabolites were evaluated for interference. The potential for interference was reduced by altering the MRM transitions chosen for the six opiates. The increased specificity of LC-MS-MS decreased the interference rate in urine to 3.9% compared to 13.6% on the in-house GC-MS method. The rate of positivity for 6-AM in meconium is described for the first time. In urine, 11.0% of morphine positive specimens were also positive for 6-AM compared to 8.3% in serum/plasma and 0.9% in meconium. Although 6-AM is infrequent in meconium, it provides a definitive proof of illegal heroin abuse by the pregnant mother. This method has been routinely used in our laboratory over the last 6 months on more than 1500 patient specimens.


Asunto(s)
Cromatografía Líquida de Alta Presión , Meconio/química , Derivados de la Morfina/análisis , Espectrometría de Masa por Ionización de Electrospray , Detección de Abuso de Sustancias/métodos , Espectrometría de Masas en Tándem/métodos , Codeína/análisis , Cromatografía de Gases y Espectrometría de Masas , Humanos , Hidrocodona/análisis , Hidromorfona/análisis , Morfina/análisis , Oxicodona/análisis , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
J Anal Toxicol ; 30(6): 353-9, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16872564

RESUMEN

The use of prescription drugs, including synthetic opiates, is increasing in the U.S., with emergency room reports showing a dramatic rise in prescription opiate abuse. As part of an ongoing study, the hair of admitted opiate users was analyzed for hydrocodone and hydromorphone, as well as codeine, morphine, and 6-acetylmorphine in order to determine if there was any correlation between self-reported frequency of opiate intake and the concentration of drug detected in hair. The hairs were confirmed using gas chromatography-mass spectrometry following screening by enzyme linked immunosorbent assay (ELISA). Twenty-four hair specimens collected from volunteers showed the presence of hydrocodone (130-15,933 pg/mg); four of those also contained hydromorphone (59-504 pg/mg). The specimens were also analyzed for morphine, codeine, and 6-acetylmorphine. Hair specimens from five self-reported codeine users showed concentrations of hydrocodone between 592 and 15,933 pg/mg. In addition, codeine was present at concentrations of 575-20,543 pg/mg, but neither morphine nor hydromorphone were present in any of those hair specimens. Though the analysis of some opiates in hair has been previously published, this is the first study where the hydrocodone and hydromorphone concentrations have been measured following self-reported opiate intake.


Asunto(s)
Cabello/química , Hidrocodona/análisis , Narcóticos/análisis , Detección de Abuso de Sustancias , Codeína/análisis , Codeína/metabolismo , Ensayo de Inmunoadsorción Enzimática/métodos , Estudios de Evaluación como Asunto , Cromatografía de Gases y Espectrometría de Masas/métodos , Cabello/metabolismo , Heroína/metabolismo , Humanos , Hidromorfona/análisis , Metadona/metabolismo , Narcóticos/metabolismo , Reproducibilidad de los Resultados , Detección de Abuso de Sustancias/métodos
18.
Fa Yi Xue Za Zhi ; 22(1): 52-4, 57, 2006 Feb.
Artículo en Chino | MEDLINE | ID: mdl-16524188

RESUMEN

OBJECTIVE: Liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for the determination of opiates in biological samples according to the emerging problem in drugs abuse. METHODS: Opiates such as heroin, 6-acetylmorphine, morphine, codeine, acetylcodeine, hydrocodone and hydromorphone were isolated from human blood, urine, oral fluid and hair using a simple extraction and consequently analyzed using LC-MS/MS. The method was evaluated by real cases. RESULTS: The mobile phase give the optimum separation for opiates. The detection limit of morphine in urine with dilution and liquid-liquid extraction and in hair is 10ng/mL, 0.01 ng/mL and 0.01 ng/mg, respectively. CONCLUSION: The method is simple and rapid, offering superior sensitivity and selectivity for opiates. The target compounds comprising hydrocodone and hydromorphone enlarge the applied area.


Asunto(s)
Cromatografía Liquida , Cabello/química , Narcóticos/análisis , Saliva/química , Detección de Abuso de Sustancias/métodos , Codeína/análisis , Medicina Legal/métodos , Humanos , Hidrocodona/análisis , Hidromorfona/análisis , Morfina/análisis , Reproducibilidad de los Resultados , Espectrometría de Masas en Tándem
19.
Rapid Commun Mass Spectrom ; 20(1): 53-60, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16315140

RESUMEN

The recently developed technique of desorption electrospray ionization (DESI) has been applied to the rapid analysis of controlled substances. Experiments have been performed using a commercial ThermoFinnigan LCQ Advantage MAX ion-trap mass spectrometer with limited modifications. Results from the ambient sampling of licit and illicit tablets demonstrate the ability of the DESI technique to detect the main active ingredient(s) or controlled substance(s), even in the presence of other higher-concentration components. Full-scan mass spectrometry data provide preliminary identification by molecular weight determination, while rapid analysis using the tandem mass spectrometry (MS/MS) mode provides fragmentation data which, when compared to the laboratory-generated ESI-MS/MS spectral library, provide structural information and final identification of the active ingredient(s). The consecutive analysis of tablets containing different active components indicates there is no cross-contamination or interference from tablet to tablet, demonstrating the reliability of the DESI technique for rapid sampling (one tablet/min or better). Active ingredients have been detected for tablets in which the active component represents less than 1% of the total tablet weight, demonstrating the sensitivity of the technique. The real-time sampling of cannabis plant material is also presented.


Asunto(s)
Preparaciones Farmacéuticas/análisis , Espectrometría de Masa por Ionización de Electrospray/métodos , Acetaminofén/análisis , Alprazolam/análisis , Cannabis/química , Combinación de Medicamentos , Hidrocodona/análisis , Legislación de Medicamentos , Metanfetamina/análisis , N-Metil-3,4-metilenodioxianfetamina/análisis , Preparaciones Farmacéuticas/química , Prednisona/análisis , Detección de Abuso de Sustancias , Factores de Tiempo
20.
Journal of Forensic Medicine ; (6): 52-57, 2006.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-983130

RESUMEN

OBJECTIVE@#Liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for the determination of opiates in biological samples according to the emerging problem in drugs abuse.@*METHODS@#Opiates such as heroin, 6-acetylmorphine, morphine, codeine, acetylcodeine, hydrocodone and hydromorphone were isolated from human blood, urine, oral fluid and hair using a simple extraction and consequently analyzed using LC-MS/MS. The method was evaluated by real cases.@*RESULTS@#The mobile phase give the optimum separation for opiates. The detection limit of morphine in urine with dilution and liquid-liquid extraction and in hair is 10ng/mL, 0.01 ng/mL and 0.01 ng/mg, respectively.@*CONCLUSION@#The method is simple and rapid, offering superior sensitivity and selectivity for opiates. The target compounds comprising hydrocodone and hydromorphone enlarge the applied area.


Asunto(s)
Humanos , Cromatografía Liquida , Codeína/análisis , Medicina Legal/métodos , Cabello/química , Hidrocodona/análisis , Hidromorfona/análisis , Morfina/análisis , Narcóticos/análisis , Reproducibilidad de los Resultados , Saliva/química , Detección de Abuso de Sustancias/métodos , Espectrometría de Masas en Tándem
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...