1.
J Robot Surg ; 18(1): 204, 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38714574

RESUMEN

Workflow for cortical bone trajectory (CBT) screws includes tapping line-to-line or under tapping by 1 mm. We describe a non-tapping, two-step workflow for CBT screw placement, and compare the safety profile and time savings to the Tap (three-step) workflow. Patients undergoing robotic assisted 1-3 level posterior fusion with CBT screws for degenerative conditions were identified and separated into either a No-Tap or Tap workflow. Number of total screws, screw-related complications, estimated blood loss, operative time, robotic time, and return to the operating room were collected and analyzed. There were 91 cases (458 screws) in the No-Tap and 88 cases (466 screws) in the Tap groups, with no difference in demographics, revision status, ASA grade, approach, number of levels fused or diagnosis between cohorts. Total robotic time was lower in the No-Tap (26.7 min) versus the Tap group (30.3 min, p = 0.053). There was no difference in the number of malpositioned screws identified intraoperatively (10 vs 6, p = 0.427), screws converted to freehand (3 vs 3, p = 0.699), or screws abandoned (3 vs 2, p = 1.000). No pedicle/pars fracture or fixation failure was seen in the No-Tap cohort and one in the Tap cohort (p = 1.00). No patients in either cohort were returned to OR for malpositioned screws. This study showed that the No-Tap screw insertion workflow for robot-assisted CBT reduces robotic time without increasing complications.


Asunto(s)
Hueso Cortical , Procedimientos Quirúrgicos Robotizados , Fusión Vertebral , Humanos , Procedimientos Quirúrgicos Robotizados/métodos , Procedimientos Quirúrgicos Robotizados/instrumentación , Masculino , Femenino , Persona de Mediana Edad , Hueso Cortical/cirugía , Anciano , Fusión Vertebral/métodos , Fusión Vertebral/instrumentación , Tempo Operativo , Tornillos Óseos , Flujo de Trabajo , Tornillos Pediculares , Adulto
2.
J Histochem Cytochem ; 72(5): 309-327, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38725403

RESUMEN

To clarify the cellular mechanism of cortical porosity induced by intermittent parathyroid hormone (PTH) administration, we examined the femoral cortical bone of mice that received 40 µg/kg/day (four times a day) human PTH (hPTH) (1-34). The PTH-driven cortical porosity initiated from the metaphyseal region and chronologically expanded toward the diaphysis. Alkaline phosphatase (ALP)-positive osteoblasts in the control mice covered the cortical surface, and endomucin-positive blood vessels were distant from these osteoblasts. In PTH-administered mice, endomucin-reactive blood vessels with TRAP-positive penetrated the ALP-positive osteoblast layer, invading the cortical bone. Statistically, the distance between endomucin-positive blood vessels and the cortical bone surface abated after PTH administration. Transmission electron microscopic observation demonstrated that vascular endothelial cells often pass through the flattened osteoblast layer and accompanied osteoclasts in the deep region of the cortical bone. The cell layers covering mature osteoblasts thickened with PTH administration and exhibited ALP, α-smooth muscle actin (αSMA), vascular cell adhesion molecule-1 (VCAM1), and receptor activator of NF-κB ligand (RANKL). Within these cell layers, osteoclasts were found near endomucin-reactive blood vessels. In PTH-administered femora, osteocytes secreted Dkk1, a Wnt inhibitor that affects angiogenesis, and blood vessels exhibited plasmalemma vesicle-associated protein, an angiogenic molecule. In summary, endomucin-positive blood vessels, when accompanied by osteoclasts in the ALP/αSMA/VCAM1/RANKL-reactive osteoblastic cell layers, invade the cortical bone, potentially due to the action of osteocyte-derived molecules such as DKK1.


Asunto(s)
Hueso Cortical , Células Endoteliales , Hormona Paratiroidea , Animales , Ratones , Hormona Paratiroidea/farmacología , Hormona Paratiroidea/administración & dosificación , Células Endoteliales/efectos de los fármacos , Células Endoteliales/metabolismo , Hueso Cortical/efectos de los fármacos , Hueso Cortical/metabolismo , Porosidad , Masculino , Osteoblastos/efectos de los fármacos , Osteoblastos/metabolismo , Inmunohistoquímica , Fémur/efectos de los fármacos , Fémur/irrigación sanguínea , Fémur/metabolismo , Humanos
3.
Int J Implant Dent ; 10(1): 23, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38713411

RESUMEN

PURPOSE: To analyze the visibility of the maxillary sinus septa (MSS) in panoramic radiography (PR) versus cone beam computed tomography (CBCT) and to investigate whether the buccal cortical bone thickness (BT) or the septa dimensions influence their visibility. METHODS: Corresponding PR and CBCT images of 355 patients were selected and examined for MSS visibility. The septa dimensions (width, height, depth) and the BT were measured. Results were analysed statistically. RESULTS: Comparing the corresponding regions on CBCT and PR, 170 MSS were identified; however, only 106 of these were also visible using PR. The MSS visibility was significantly higher on CBCT versus PR images (P1: p = 0.039, P2: p = 0.015, M1: p = 0.041, M2: p = 0.017, M3: p = 0.000), except region C (p = 0.625). Regarding the measurements of MSS dimensions, only the height in region M1 (p = 0.013) and the width in region P2 (p = 0.034) were significantly more visible on CBCT. The BT in the area of the MSS was found to have a marginal influence on its visibility on the PR images only in regions M3 and M1 (M3: p = 0.043, M1: p = 0.047). In terms of MSS visibility based on the dimensions, significance was found for all three influencing variables only in region P2 (width; p = 0.041, height; p = 0.001, depth; p = 0.007). There were only isolated cases of further significance: M3 for width (p = 0.043), M2 for height (p = 0.024), and P1 for depth (p = 0.034), no further significance was noted. CONCLUSION: MSS visibility appears significantly higher on CBCT versus PR images. It is concluded that the septa dimensions and BT can influence MSS visibility on PR images just in certain regions.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Hueso Cortical , Seno Maxilar , Radiografía Panorámica , Humanos , Tomografía Computarizada de Haz Cónico/métodos , Radiografía Panorámica/métodos , Seno Maxilar/diagnóstico por imagen , Seno Maxilar/anatomía & histología , Estudios Retrospectivos , Masculino , Femenino , Persona de Mediana Edad , Adulto , Hueso Cortical/diagnóstico por imagen , Hueso Cortical/anatomía & histología , Anciano , Adulto Joven , Anciano de 80 o más Años
4.
Jt Dis Relat Surg ; 35(2): 417-421, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38727123

RESUMEN

Although hemangiomas are the most common soft tissue tumors, intramuscular hemangiomas account for only 0.8% of all vascular tumors. These lesions are rarely located adjacent to the bone and cause changes in the adjacent bone. They are often mistakenly diagnosed as bone tumors. In this study, a case of a 19-year-old male patient with intramuscular hemangioma causing cortical thickening was reported.


Asunto(s)
Neoplasias Óseas , Hemangioma , Hipertrofia , Neoplasias de los Músculos , Humanos , Masculino , Hemangioma/patología , Hemangioma/diagnóstico , Hemangioma/diagnóstico por imagen , Diagnóstico Diferencial , Adulto Joven , Neoplasias Óseas/diagnóstico , Neoplasias Óseas/patología , Neoplasias de los Músculos/patología , Neoplasias de los Músculos/diagnóstico por imagen , Neoplasias de los Músculos/diagnóstico , Hipertrofia/patología , Imagen por Resonancia Magnética , Hueso Cortical/patología , Hueso Cortical/diagnóstico por imagen , Tomografía Computarizada por Rayos X
5.
Phys Med Biol ; 69(11)2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38631364

RESUMEN

Cortical bone is characterized by a dense solid matrix permeated by fluid-filled pores. Ultrasound scattering has potential for the non-invasive evaluation of changes in bone porosity. However, there is an incomplete understanding of the impact of ultrasonic absorption in the solid matrix on ultrasound scattering. In this study, maps were derived from scanning acoustic microscopy images of human femur cross-sections. Finite-difference time domain ultrasound scatter simulations were conducted on these maps. Pore density, diameter distribution of the pores, and nominal absorption values in the solid and fluid matrices were controlled. Ultrasound pulses with a central frequency of 8.2 MHz were propagated, both in through-transmission and backscattering configurations. From these data, the scattering, bone matrix absorption, and attenuation extinction lengths were calculated. The results demonstrated that as absorption in the solid matrix was varied, the scattering, absorption, and attenuation extinction lengths were significantly impacted. It was shown that for lower values of absorption in the solid matrix (less than 2 dB mm-1), attenuation due to scattering dominates, whereas at higher values of absorption (more than 2 dB mm-1), attenuation due to absorption dominates. This will impact how ultrasound attenuation and scattering parameters can be used to extract quantitative information on bone microstructure.


Asunto(s)
Hueso Cortical , Dispersión de Radiación , Hueso Cortical/diagnóstico por imagen , Humanos , Ondas Ultrasónicas , Ultrasonografía/métodos , Matriz Ósea/metabolismo , Matriz Ósea/diagnóstico por imagen , Fémur/diagnóstico por imagen
6.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 55(2): 303-308, 2024 Mar 20.
Artículo en Chino | MEDLINE | ID: mdl-38645868

RESUMEN

Objective: To compare the clinical effects of cortical bone trajectory screws and traditional pedicle screws in posterior lumbar fusion. Methods: A retrospective study was conducted to analyze lumbar degeneration patients who underwent surgical treatment at our hospital between January 2016 and January 2019. A total of 123 patients who met the inclusion criteria were enrolled. The subjects were divided into two groups according to their surgical procedures and the members of the two groups were matched by age, sex, and the number of fusion segments. There were 63 patients in the traditional pedicle screws (PS) group and 60 in the cortical bone trajectory screws (CBTS) group. The outcomes of the two groups were compared. The primary outcome measures were perioperative conditions, including operation duration, estimated intraoperative blood loss (EBL), and length-of-stay (LOS), visual analog scale (VAS) score, Oswestry Disability Index (ODI) score, and interbody fusion rate. The secondary outcome measures were the time to postoperative ambulation and the incidence of complications. VAS scores and ODI scores were assessed before operation, 1 week, 1 month, 3 months, and 12 months after operation, and at the final follow-up. The interbody fusion rate was assessed in 1 year and 2 years after the operation and at the final follow-up. Results: The CBTS group showed a reduction in operation duration ([142.8±13.1] min vs. [174.7±15.4] min, P<0.001), LOS ([9.5±1.5] d vs. [12.0±2.0] d, P<0.001), and EBL ([194.2±38.3] mL vs. [377.5±33.1] mL, P<0.001) in comparison with the PS group. The VAS score for back pain in the CBTS group was lower than that in the PS group at 1 week and 1 month after operation and the ODI score in the CBTS group was lower than that in the PS group at 1 month after operation, with the differences being statistically significant (P<0.05). At each postoperative time point, the VAS score for leg pain and the interbody fusion rate did not show significant difference between the two groups. The VAS score for back and leg pain and the ODI score at each time point after operation in both the CBTS group and the PS group were significantly lower than those before operation (P<0.05). No significant difference was found in the time to postoperative ambulation or the overall complication incidence between the two groups. Conclusion: The CBTS technique could significantly shorten the operation duration and LOS, reduce EBL, and achieve the same effect as the PS technique does in terms of intervertebral fusion rate, pain relief, functional improvement, and complication incidence in patients undergoing posterior lumbar fusion.


Asunto(s)
Hueso Cortical , Vértebras Lumbares , Tornillos Pediculares , Fusión Vertebral , Humanos , Fusión Vertebral/métodos , Fusión Vertebral/instrumentación , Vértebras Lumbares/cirugía , Estudios Retrospectivos , Masculino , Femenino , Hueso Cortical/cirugía , Tempo Operativo , Tiempo de Internación , Persona de Mediana Edad , Resultado del Tratamiento , Degeneración del Disco Intervertebral/cirugía , Tornillos Óseos , Pérdida de Sangre Quirúrgica/estadística & datos numéricos
7.
J Mech Behav Biomed Mater ; 153: 106487, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38490048

RESUMEN

Computational models of mature bone have been used to predict fracture; however, analogous study of immature diaphyseal fracture has not been conducted due to sparse experimental mechanical data. A model of immature bone fracture may be used to aid in the differentiation of accidental and non-accidental trauma fractures in young, newly ambulatory children (0-3 years). The objective of this study was to characterize the evolution of tissue-level mechanical behavior, composition, and microstructure of maturing cortical porcine bone with uniaxial tension, Raman spectroscopy, and light microscopy as a function of maturation. We asked: 1) How do the monotonic uniaxial tensile properties change with maturation and displacement rate; 2) How does the composition and microstructure change with maturation; and 3) Is there a correlation between composition and tensile properties with maturation? Elastic modulus (p < 0.001), fracture stress (p < 0.001), and energy absorption (p < 0.014) increased as a function of maturation at the quasistatic rate by 110%, 86%, and 96%, respectively. Fracture stress also increased by 90% with maturation at the faster rate (p = 0.001). Fracture stress increased as a function of increasing displacement rate by 28% (newborn p = 0.048; 1-month p = 0.004; 3-month p= < 0.001), and fracture strain decreased by 68% with increasing displacement rate (newborn p = 0.002; 1-month p = 0.036; 3-month p < 0.001). Carbonate-to-phosphate ratio was positively linearly related to elastic modulus, and fracture stress was positively related to carbonate-to-phosphate ratio and matrix maturation ratio. The results of this study support that immature bone is strain-rate dependent and becomes more brittle at faster rates, contributing to the foundation upon which a computational model can be built to evaluate immature bone fracture.


Asunto(s)
Hueso Cortical , Fracturas Óseas , Niño , Recién Nacido , Humanos , Animales , Porcinos , Fenómenos Biomecánicos , Fosfatos , Carbonatos , Estrés Mecánico
8.
J Mech Behav Biomed Mater ; 153: 106468, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38493561

RESUMEN

A 2D plane strain extended finite element method (XFEM) model was developed to simulate three-point bending fracture toughness tests for human bone conducted in hydrated and dehydrated conditions. Bone microstructures and crack paths observed by micro-CT imaging were simulated using an XFEM damage model. Critical damage strains for the osteons, matrix, and cement lines were deduced for both hydrated and dehydrated conditions and it was found that dehydration decreases the critical damage strains by about 50%. Subsequent parametric studies using the various microstructural models were performed to understand the impact of individual critical damage strain variations on the fracture behavior. The study revealed the significant impact of the cement line critical damage strains on the crack paths and fracture toughness during the early stages of crack growth. Furthermore, a significant sensitivity of crack growth resistance and crack paths on critical strain values of the cement lines was found to exist for the hydrated environments where a small change in critical strain values of the cement lines can alter the crack path to give a significant reduction in fracture resistance. In contrast, in the dehydrated state where toughness is low, the sensitivity to changes in critical strain values of the cement lines is low. Overall, our XFEM model was able to provide new insights into how dehydration affects the micromechanisms of fracture in bone and this approach could be further extended to study the effects of aging, disease, and medical therapies on bone fracture.


Asunto(s)
Deshidratación , Fracturas Óseas , Humanos , Modelos Biológicos , Hueso Cortical/diagnóstico por imagen , Huesos , Fracturas Óseas/diagnóstico por imagen
9.
Medicina (Kaunas) ; 60(2)2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38399527

RESUMEN

Background and Objectives: Surgical guides might impede the flow of coolant to the implant drills during the preparation of the implant bed, potentially contributing to increased temperatures during bone drilling. The objective of this experimental study was to assess the cooling efficiency of various guiding cylinder designs for sleeveless surgical guides used in guided surgery. Materials and Methods: In this experimental study, surgical guides with three different guiding cylinder designs were printed. One group had solid cylinders (control) and two test groups (cylinders with pores and cylinders with windows). Forty customized polyurethane blocks with type III bone characteristics were fitted into the guide and fixed in a vise, and implant bed preparations were completed using a simplified drilling protocol with and without irrigation. An infrared thermographic camera was used to record the temperature changes during drilling at the coronal, middle, and apical areas. ANOVA test and Games-Howell post hoc test were used to determine significant thermal differences among groups. Results: A significant thermal increase was observed at the coronal area in the group without irrigation (39.69 ± 8.82) (p < 0.05). The lowest thermal increase was recorded at the surgical guides with windows (21.451 ± 0.703 °C) compared to solid (25.005 ± 0.586 °C) and porous surgical guides (25.630 ± 1.004) (p < 0.05). In the middle and apical areas, there were no differences between solid and porous cylinders (p > 0.05). Conclusions: 3D-printed sleeveless surgical guides with window openings at the guiding cylinders reduce the temperature elevation at the cortical bone in guided implant surgery.


Asunto(s)
Osteotomía , Prótesis e Implantes , Humanos , Hueso Cortical , Microcirugia , Impresión Tridimensional
10.
J Robot Surg ; 18(1): 78, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38358573

RESUMEN

Robot-assisted (RA) technology has been shown to be a safe aid in spine surgery, this meta-analysis aims to compare surgical parameters and clinical indexes between robot-assisted cortical bone trajectory (CBT) and fluoroscopy-assisted (FA) cortical bone trajectory in spinal surgery. We searched databases such as PubMed, Web of Science, the Cochrane Library, and the China National Knowledge Infrastructure. The study selection process was guided by the PICOS (Patient/Problem, Intervention, Comparison, Outcome, Study Design) strategy. The risk of bias in non-randomized comparative studies was assessed using the risk of bias in non-randomized studies of interventions (ROBINS-I) tool. We performed this meta-analysis using RevMan 5.3 software (Cochrane Collaboration, Copenhagen, Denmark), and the level of statistical significance was set at P < 0.05. Six articles involving 371 patients and 1535 screws were included in this meta-analysis. RA-CBT outperformed FA-CBT in terms of various parameters, such as accuracy of pedicle screw position (both Gertzbein-Robbins scale and Ding scale), avoidance of superior facet joint violation (FJV), and reduction of neurological injury. Our meta-analysis offered a thorough evaluation of the efficacy and safety of RA-CBT in spinal surgery. The findings revealed that RA-CBT produced statistically significant results in terms of pedicle screw position accuracy and superior facet joint violation prevention. In terms of surgical parameters and clinical indexes, future research and clinical practice should investigate the efficacy of RA-CBT further. The study was registered in the PROSPERO (CRD42023466280).


Asunto(s)
Tornillos Pediculares , Procedimientos Quirúrgicos Robotizados , Robótica , Humanos , Procedimientos Quirúrgicos Robotizados/métodos , Hueso Cortical , Fluoroscopía
11.
Bone ; 181: 117031, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38311304

RESUMEN

INTRODUCTION: Conventional bone imaging methods primarily use X-ray techniques to assess bone mineral density (BMD), focusing exclusively on the mineral phase. This approach lacks information about the organic phase and bone water content, resulting in an incomplete evaluation of bone health. Recent research highlights the potential of ultrashort echo time magnetic resonance imaging (UTE MRI) to measure cortical porosity and estimate BMD based on signal intensity. UTE MRI also provides insights into bone water distribution and matrix organization, enabling a comprehensive bone assessment with a single imaging technique. Our study aimed to establish quantifiable UTE MRI-based biomarkers at clinical field strength to estimate BMD and microarchitecture while quantifying bound water content and matrix organization. METHODS: Femoral bones from 11 cadaveric specimens (n = 4 males 67-92 yrs of age, n = 7 females 70-95 yrs of age) underwent dual-echo UTE MRI (3.0 T, 0.45 mm resolution) with different echo times and high resolution peripheral quantitative computed tomography (HR-pQCT) imaging (60.7 µm voxel size). Following registration, a 4.5 mm HR-pQCT region of interest was divided into four quadrants and used across the multi-modal images. Statistical analysis involved Pearson correlation between UTE MRI porosity index and a signal-intensity technique used to estimate BMD with corresponding HR-pQCT measures. UTE MRI was used to calculate T1 relaxation time and a novel bound water index (BWI), compared across subregions using repeated measures ANOVA. RESULTS: The UTE MRI-derived porosity index and signal-intensity-based estimated BMD correlated with the HR-pQCT variables (porosity: r = 0.73, p = 0.006; BMD: r = 0.79, p = 0.002). However, these correlations varied in strength when we examined each of the four quadrants (subregions, r = 0.11-0.71). T1 relaxometry and the BWI exhibited variations across the four subregions, though these differences were not statistically significant. Notably, we observed a strong negative correlation between T1 relaxation time and the BWI (r = -0.87, p = 0.0006). CONCLUSION: UTE MRI shows promise for being an innocuous method for estimating cortical porosity and BMD parameters while also giving insight into bone hydration and matrix organization. This method offers the potential to equip clinicians with a more comprehensive array of imaging biomarkers to assess bone health without the need for invasive or ionizing procedures.


Asunto(s)
Hueso Cortical , Imagen por Resonancia Magnética , Masculino , Femenino , Humanos , Niño , Estudios de Factibilidad , Microtomografía por Rayos X , Hueso Cortical/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Agua
12.
Bone ; 181: 117041, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38325648

RESUMEN

Chronic heavy alcohol consumption may influence the skeleton by suppressing intracortical bone remodeling which may impact the quality of bone and its mechanical properties. However, this aspect has not been thoroughly assessed in either humans or animal models whose cortical bone microstructure resembles the microstructure of human cortical bone. The current study is the first to investigate the effects of chronic heavy alcohol consumption on various mechanical properties of bone in a non-human primate model with intracortical remodeling. Male rhesus macaques (5.3 years old at the initiation of treatment) were induced to drink alcohol and then given the choice to voluntarily self-administer water or ethanol (4 % w/v) for approximately 14 months, followed by three abstinence phases (lasting 34, 41, and 39-46 days) with approximately 3 months of ethanol access in between. During the initial 14 months of open-access, monkeys in the alcohol group consumed an average of 2.9 ± 0.8 g/kg/d ethanol (mean ± SD) resulting in a blood ethanol concentration of 89 ± 47 mg/dl in longitudinal samples taken at 7 h after the daily sessions began. To understand the impact of alcohol consumption on material properties, various mechanical tests were conducted on the distal tibia diaphysis of 2-5 monkeys per test group, including dynamic mechanical analysis (DMA) testing, nano-indentation, microhardness testing, compression testing, and fracture resistance curve (R-curve) testing. Additionally, compositional analyses were performed using Fourier-transform infrared (FTIR) spectroscopy. Significant differences in microhardness, compressive stress-strain response, and composition were not observed with alcohol consumption, and only minor differences were detected in hardness and elastic modulus of the matrix and osteons from nanoindentation. Furthermore, the R-curves of both groups overlapped, with similar crack initiation toughness, despite a significant decrease in crack growth toughness (p = 0.032) with alcohol consumption. However, storage modulus (p = 0.029) and loss factor (p = 0.015) from DMA testing were significantly increased in the alcohol group compared to the control group, while loss modulus remained unchanged. These results indicate that heavy alcohol consumption may have only a minor influence on the material properties and the composition of cortical bone in young adult male rhesus macaques.


Asunto(s)
Huesos , Hueso Cortical , Animales , Masculino , Macaca mulatta , Consumo de Bebidas Alcohólicas , Etanol
13.
J Vet Med Sci ; 86(3): 325-332, 2024 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-38311401

RESUMEN

This study was performed to evaluate cortical bone strength in dogs using a quantitative ultrasound measurement device. In this study, 16 clinically healthy dogs with no lameness underwent measurement of the ultrasound propagation velocity of cortical bone (namely, speed of sound [SOS]) at the radius and tibia. Additionally, computed tomography examination with a calibration phantom was performed in 10 dogs. We calculated the bone mineral density (BMD) and Young's modulus from the computed tomography data using bone strength evaluation software. SOS, BMD, and Young's modulus were statistically compared between the radius and tibia. In addition, we examined the correlation between SOS and BMD and between SOS and Young's modulus. We also examined the correlation between SOS and age in the 13 dogs whose age was known. BMD and Young's modulus were not significantly different between the radius and tibia, but SOS was significantly different (P<0.05). Moreover, SOS and BMD showed a positive correlation in both radius and tibia. Similarly, SOS and Young's modulus showed a positive correlation. In addition, SOS and age showed a strong positive correlation (radius: r=0.77, P<0.05, tibia: r=0.83, P<0.05). Our finding that SOS of the radius and tibia cortical bone was correlated with BMD and Young's modulus indicates that quantitative ultrasound can be useful for evaluating cortical bone strength in dogs.


Asunto(s)
Densidad Ósea , Huesos , Perros , Animales , Huesos/diagnóstico por imagen , Ultrasonografía/veterinaria , Hueso Cortical/diagnóstico por imagen , Tibia/diagnóstico por imagen
14.
World Neurosurg ; 184: e546-e553, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38320649

RESUMEN

OBJECTIVE: We describe the incidence of, and identify the risk factors for, a medial breach of the pedicle wall during robotic-assisted cortical bone trajectory (RA-CBT) screw insertion. METHODS: We analyzed a consecutive series of adult patients who underwent RA-CBT screw placement from January 2019 to July 2022. To assess the pedicle wall medial breach, postoperative computed tomography (CT) images were analyzed. Patient demographic data and screw data were compared between patients with and without a medial breach. The Hounsfield units (HUs) on the L1 midvertebral axial CT scan was used to evaluate bone quality. RESULTS: Of 784 CBT screws in 145 patients, 30 (3.8%) had a medial breach in 23 patients (15.9%). One screw was grade 2, and the others were grade 1. Patients with a medial breach had a lower HU value compared with the patients without a medial breach (123.3 vs. 150.5; P = 0.027). A medial breach was more common in the right than left side (5.5% vs. 2.0%; P = 0.014). More than one half of the screws with a medial breach were found in the upper instrumented vertebra (UIV) compared with the middle construct or lowest instrumented vertebra (6.7% vs. 1.3% vs. 2.7%; P = 0.003). Binary logistic regression showed that low HU values, right-sided screw placement, and UIV were associated with a medial breach. No patients returned to the operating room for screw malposition. No differences were found in the clinical outcomes between patients with and without a medial breach. CONCLUSIONS: The incidence of pedicle wall medial breach was 3.8% of RA-CBT screws in the postoperative CT images. A low HU value measured in the L1 axial image, right-sided screw placement, and UIV were associated with an increased risk of medial breach for RA-CBT screw placement.


Asunto(s)
Tornillos Pediculares , Procedimientos Quirúrgicos Robotizados , Fusión Vertebral , Adulto , Humanos , Procedimientos Quirúrgicos Robotizados/efectos adversos , Procedimientos Quirúrgicos Robotizados/métodos , Tornillos Pediculares/efectos adversos , Hueso Cortical/diagnóstico por imagen , Hueso Cortical/cirugía , Factores de Riesgo , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Fusión Vertebral/efectos adversos , Fusión Vertebral/métodos , Estudios Retrospectivos
15.
Am J Biol Anthropol ; 184(1): e24902, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38400773

RESUMEN

OBJECTIVES: Reconstruction of fossil hominin manual behaviors often relies on comparative analyses of extant hominid hands to understand the relationship between hand use and skeletal morphology. In this context, the intermediate phalanges remain understudied. Thus, here we investigate cortical bone morphology of the intermediate phalanges of extant hominids and compare it to the cortical structure of the proximal phalanges, to investigate the relationship between cortical bone structure and inferred loading during manual behaviors. MATERIALS AND METHODS: Using micro-CT data, we analyze cortical bone structure of the intermediate phalangeal shaft of digits 2-5 in Pongo pygmaeus (n = 6 individuals), Gorilla gorilla (n = 22), Pan spp. (n = 23), and Homo sapiens (n = 23). The R package morphomap is used to study cortical bone distribution, cortical thickness and cross-sectional properties within and across taxa. RESULTS: Non-human great apes generally have thick cortical bone on the palmar shaft, with Pongo only having thick cortex on the peaks of the flexor sheath ridges, while African apes have thick cortex along the entire flexor sheath ridge and proximal to the trochlea. Humans are distinct in having thicker dorsal shaft cortex as well as thick cortex at the disto-palmar region of the shaft. DISCUSSION: Variation in cortical bone distribution and properties of the intermediate phalanges is consistent with differences in locomotor and manipulative behaviors in extant great apes. Comparisons between the intermediate and proximal phalanges reveals similar patterns of cortical bone distribution within each taxon but with potentially greater load experienced by the proximal phalanges, even in knuckle-walking African apes. This study provides a comparative context for the reconstruction of habitual hand use in fossil hominins and hominids.


Asunto(s)
Hominidae , Animales , Humanos , Hominidae/anatomía & histología , Gorilla gorilla/anatomía & histología , Locomoción , Pongo , Pongo pygmaeus/anatomía & histología , Hueso Cortical
16.
Eur Radiol Exp ; 8(1): 21, 2024 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-38316687

RESUMEN

BACKGROUND: We investigated the relationship of two commonly used quantitative ultrasound (QUS) parameters, speed of sound (SoS) and attenuation coefficient (α), with water and macromolecular contents of bovine cortical bone strips as measured with ultrashort echo time (UTE) magnetic resonance imaging (MRI). METHODS: SoS and α were measured in 36 bovine cortical bone strips utilizing a single-element transducer with nominal 5 MHz center frequency based on the time of flight principles after accommodating for reflection losses. Specimens were then scanned using UTE MRI to measure total, bound, and pore water proton density (TWPD, BWPD, and PWPD) as well as macromolecular proton fraction and macromolecular transverse relaxation time (T2-MM). Specimens were also scanned using microcomputed tomography (µCT) at 9-µm isometric voxel size to measure bone mineral density (BMD), porosity, and pore size. The elastic modulus (E) of each specimen was measured using a 4-point bending test. RESULTS: α demonstrated significant positive Spearman correlations with E (R = 0.69) and BMD (R = 0.44) while showing significant negative correlations with porosity (R = -0.41), T2-MM (R = -0.47), TWPD (R = -0.68), BWPD (R = -0.67), and PWPD (R = -0.45). CONCLUSIONS: The negative correlation between α and T2-MM is likely indicating the relationship between QUS and collagen matrix organization. The higher correlations of α with BWPD than with PWPD may indicate that water organized in finer structure (bound to matrix) provides lower acoustic impedance than water in larger pores, which is yet to be investigated thoroughly. RELEVANCE STATEMENT: This study highlights the importance of future investigations exploring the relationship between QUS measures and all major components of the bone, including the collagenous matrix and water. Investigating the full potential of QUS and its validation facilitates a more affordable and accessible tool for bone health monitoring in clinics. KEY POINTS: • Ultrasound attenuation demonstrated significant positive correlations with bone mechanics and mineral density. • Ultrasound attenuation demonstrated significant negative correlations with porosity and bone water contents. • This study highlights the importance of future investigations exploring the relationship between QUS measures and all major components of the bone.


Asunto(s)
Huesos , Protones , Animales , Bovinos , Microtomografía por Rayos X , Huesos/diagnóstico por imagen , Hueso Cortical/diagnóstico por imagen , Agua
17.
Acta Neurochir (Wien) ; 166(1): 74, 2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38332369

RESUMEN

BACKGROUND: Endoscopically assisted screw fixation with lumbar interbody fusion is rarely performed. We succeeded in implanting the cortical bone trajectory (CBT) screws under the guidance of unilateral biportal endoscopy (UBE). METHOD: We attempted endoscopically assisted screw fixation in a patient with degenerative spondylolisthesis. Through a third portal, ipsilateral CBT screws were implanted without complications. CONCLUSIONS: We successfully performed unilateral biportal endoscopic lumbar interbody fusion (ULIF) with CBT and reversed CBT screws. Compared with percutaneous pedicle screw (PPS) placement, this procedure is a minimally invasive, endoscopic alternative that allows precise screw placement.


Asunto(s)
Tornillos Pediculares , Fusión Vertebral , Espondilolistesis , Humanos , Espondilolistesis/diagnóstico por imagen , Espondilolistesis/cirugía , Endoscopía , Hueso Cortical/diagnóstico por imagen , Hueso Cortical/cirugía , Huesos , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Fusión Vertebral/métodos , Resultado del Tratamiento
18.
J Mech Behav Biomed Mater ; 152: 106442, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38330876

RESUMEN

Antlers are bony structures composed predominantly of primary osteons with unique mechanical properties due to their specific use by deer as weapon and shield. Antler bone fracture resistance has attracted prior scrutiny through experimental tests and theoretical models. To characterize antler mechanical properties, compression of cubes, or bending or tensioning of rectangular bars have been performed in the literature with variations in the protocols precluding comparisons of the data. Compression testing is a widely used experimental technique for determining the mechanical properties of specimens excised from cortical or cancellous regions of bone. However, the recommended geometry for compression tests is the cylinder, being more representative of the real performances of the material. The purpose of research was to report data for compressive strength and stiffness of antler cortical bone following current guidelines. Cylinders (n = 296) of dry antler cortical bone from either the main beam or the tines of Cervus elaphus, Rangifer tarandus, Cervus nippon and Damadama were tested. This study highlights the fact that compression of antler cortical bone cylinders following current guidelines is feasible but not applicable in all species. Standardization of the testing protocols could help to compare data from the literature. This study also confirms that sample localization has no effect on the mechanical properties, that sample density has a significant impact and allows enriching the knowledge of the mechanical properties of dry antler cortical bone.


Asunto(s)
Cuernos de Venado , Ciervos , Animales , Hueso Cortical , Fuerza Compresiva , Fenómenos Físicos
19.
J Mech Behav Biomed Mater ; 152: 106432, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38354566

RESUMEN

Various studies have shown that the water content affects the elastic behavior of cortical bone. However, there is disagreement regarding the reversibility of the elastic behavior with rewetting. This study investigates this issue using an intrinsic approach, i.e., moisture manipulation and material testing were always carried out on the same specimen. The test results were then evaluated separately for each of several specimens. In total, 24 specimens of human cortical bone from the ischiopubic ramus were examined. The water content was varied in 11 steps, and the corresponding elastic moduli were determined using three-point bending tests within the elastic range. Moisture adjustment was achieved mainly using desiccators, accelerated by forced convection. Reference samples stored in the same manner were evaluated microscopically. The experiments confirmed the known correlation between water content reduction and stiffness increase of cortical bone. Complete drying increased the elastic modulus by about 83 %. By rewetting, the stiffness was significantly reduced again, though not only to the initial state, but even about 24 % below this. Thus, an irreversible alteration of the elastic behavior was observed. Decay of the reference samples was not observed. Therefore, decay is not the main reason for the significant loss of stiffness. In terms of the storage conditions for cortical bone specimens, an environment with 100 % relative humidity yielded the best match with the initial state. This storage method can therefore be recommended for biomechanical specimens used to determine in-vivo-like material parameters.


Asunto(s)
Huesos Pélvicos , Humanos , Pelvis , Hueso Cortical , Módulo de Elasticidad , Agua
20.
J Mech Behav Biomed Mater ; 151: 106403, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38237206

RESUMEN

This study proposed and validated a 2D finite element (FE) model for conducting in-silico simulations of in-situ nanoindentation tests on mineralized collagen fibrils (MCF) and the extrafibrillar matrix (EFM) within human cortical bone. Initially, a multiscale cohesive FE model was developed by adapting a previous model of bone lamellae, encompassing both MCF and EFM. Subsequently, nanoindentation tests were simulated in-silico using this model, and the resulting predictions were compared to AFM nanoindentation test data to verify the model's accuracy. The FE model accurately predicted nanoindentation results under wet conditions, closely aligning with outcomes obtained from AFM nanoindentation tests. Specifically, it successfully mirrored the traction/separation curve, nanoindentation modulus, plastic energy dissipation, and plastic energy ratio obtained from AFM nanoindentation tests. Additionally, this in-silico model demonstrated its ability to capture alterations in nanoindentation properties caused by the removal of bound water, by considering corresponding changes in mechanical properties of the collagen phase and the interfaces among bone constituents. Notably, significant changes in the elastic modulus and plastic energy dissipation were observed in both MCF and EFM compartments of bone, consistent with observations in AFM nanoindentation tests. These findings indicate that the proposed in-silico model effectively captures the influence of ultrastructural changes on bone's mechanical properties at sub-lamellar levels. Presently, no experimental methods exist to conduct parametric studies elucidating the ultrastructural origins of bone tissue fragility. The introduction of this in-silico model presents an invaluable tool to bridge this knowledge gap in the future.


Asunto(s)
Huesos , Hueso Cortical , Humanos , Análisis de Elementos Finitos , Estrés Mecánico , Huesos/metabolismo , Hueso Cortical/metabolismo , Colágeno/química