Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.452
Filtrar
1.
Trials ; 25(1): 305, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38711052

RESUMEN

BACKGROUND: To analyze the perioperative bleeding and hidden blood loss (HBL) of sacroiliac screw minimally invasive treatment of pelvic posterior ring injury and explore the influential factors of HBL after operation for providing reference for clinical treatment. METHOD: A retrospective analysis was conducted on data from 369 patients with posterior pelvic ring injuries treated with sacroiliac screws internal fixation at our hospital from January 2015 to January 2022. The research was registered in the Chinese Clinical Trial Registry in July 2022 (ChiCTR2200061866). The total blood loss (TBL) and HBL of patients were counted, and the factors such as gender, age, and surgical duration were statistically analyzed. The influential factors of HBL were analyzed by multiple linear regression. RESULTS: The TBL was 417.96 ± 98.05 ml, of which the visible blood loss (VBL) was 37.00 ± 9.0 ml and the HBL was 380.96 ± 68.8 ml. The HBL accounted for 91.14 ± 7.36% of the TBL. Gender, surgical duration, fixed position, and fixed depth had significant effects on the HBL (P < 0.05). CONCLUSIONS: The HBL was the main cause of anemia after minimally invasive treatment of posterior pelvic ring injury with a sacroiliac screw. Gender, surgical duration, fixed position, and fixed depth were closely related to the occurrence of HBL. In clinical treatment, we should consider these influential factors and take effective measures to reduce the impact of HBL on patients.


Asunto(s)
Pérdida de Sangre Quirúrgica , Tornillos Óseos , Fijación Interna de Fracturas , Huesos Pélvicos , Humanos , Masculino , Femenino , Estudios Retrospectivos , Huesos Pélvicos/lesiones , Huesos Pélvicos/cirugía , Adulto , Persona de Mediana Edad , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Resultado del Tratamiento , Factores de Riesgo , Adulto Joven , Fracturas Óseas/cirugía , Fracturas Óseas/diagnóstico por imagen , Factores de Tiempo , China , Anciano , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Anemia/etiología
2.
BMC Musculoskelet Disord ; 25(1): 384, 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38755628

RESUMEN

BACKGROUND: Customized 3D-printed pelvic implants with a porous structure have revolutionized periacetabular pelvic defect reconstruction after tumor resection, offering improved osteointegration, long-term stability, and anatomical fit. However, the lack of an established classification system hampers implementation and progress. METHODS: We formulated a novel classification system based on pelvic defect morphology and 3D-printed hemipelvis endoprostheses. It integrates surgical approach, osteotomy guide plate and prosthesis design, postoperative rehabilitation plans, and perioperative processes. RESULTS: Retrospectively analyzing 60 patients (31 males, 29 females), we classified them into Type A (15 patients: Aa = 6, Ab = 9), Type B (27 patients: Ba = 15, Bb = 12), Type C (17 patients). All underwent customized osteotomy guide plate-assisted tumor resection and 3D-printed hemipelvic endoprosthesis reconstruction. Follow-up duration was median 36.5 ± 15.0 months (range, 6 to 74 months). The mean operating time was 430.0 ± 106.7 min, intraoperative blood loss 2018.3 ± 1305.6 ml, transfusion volume 2510.0 ± 1778.1 ml. Complications occurred in 13 patients (21.7%), including poor wound healing (10.0%), deep prosthesis infection (6.7%), hip dislocation (3.3%), screw fracture (1.7%), and interface loosening (1.7%). VAS score improved from 5.5 ± 1.4 to 1.7 ± 1.3, MSTS-93 score from 14.8 ± 2.5 to 23.0 ± 5.6. Implant osseointegration success rate was 98.5% (128/130), with one Type Ba patient experiencing distal prosthesis loosening. CONCLUSION: The West China classification may supplement the Enneking and Dunham classification, enhancing interdisciplinary communication and surgical outcomes. However, further validation and wider adoption are required to confirm clinical effectiveness.


Asunto(s)
Acetábulo , Neoplasias Óseas , Impresión Tridimensional , Diseño de Prótesis , Humanos , Femenino , Masculino , Estudios Retrospectivos , Adulto , Persona de Mediana Edad , Acetábulo/cirugía , Acetábulo/diagnóstico por imagen , Neoplasias Óseas/cirugía , Neoplasias Óseas/diagnóstico por imagen , Adulto Joven , Osteotomía/métodos , Procedimientos de Cirugía Plástica/métodos , Procedimientos de Cirugía Plástica/instrumentación , Adolescente , Anciano , Resultado del Tratamiento , Complicaciones Posoperatorias/etiología , Estudios de Seguimiento , Huesos Pélvicos/cirugía , Huesos Pélvicos/diagnóstico por imagen
3.
Medicine (Baltimore) ; 103(20): e38258, 2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38758846

RESUMEN

BACKGROUND: The aim of this study was to compare the biomechanical performance of pedicle screw construction and locking compression plate fixation in posterior pelvic ring injuries analyzed by finite element method. METHODS: A 3-dimensional finite element model of the spine-pelvis-femur complex with ligaments was reconstructed from computed tomography images. An unstable posterior pelvic ring injury was created, which was fixed with a pedicle screw construction or locking compression plate. A follower load of 400 N was applied to the upper surface of the vertebrae to simulate the upper body weight, while the ends of the proximal femurs were fixed. The construct stiffness, the maximum vertical displacement, the maximum posterior displacement, the maximum right displacement, and the overall maximum displacement of the sacrum, and stress distributions of the implants and pelvises were assessed. RESULTS: The construct stiffness of the pedicle screw model (435.14 N/mm) was 2 times that of the plate model (217.01 N/mm). The maximum vertical displacement, the maximum posterior displacement, the maximum right displacement, and the overall maximum displacement of the sacrum in the pedicle screw model were smaller than those in the plate model (0.919, 1.299, 0.259, and 1.413 mm in the pedicle screw model, and 1.843, 2.300, 1.053, and 2.895 mm in the plate model, respectively). The peak stresses of the implant and pelvis in the pedicle screw model decreased by 80.4% and 25% when compared with the plate model (44.57 and 34.48 MPa in the pedicle screw model, and 227.47 and 45.97 MPa in the plate model, respectively). CONCLUSION: The study suggested that the pedicle screw construction could provide better fixation stability than the locking compression plate and serves as the recommended fixation method for the treatment of posterior pelvic ring injuries.


Asunto(s)
Placas Óseas , Análisis de Elementos Finitos , Fijación Interna de Fracturas , Tornillos Pediculares , Huesos Pélvicos , Humanos , Huesos Pélvicos/lesiones , Huesos Pélvicos/cirugía , Fenómenos Biomecánicos , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Tomografía Computarizada por Rayos X , Fracturas Óseas/cirugía
4.
Am J Case Rep ; 25: e942126, 2024 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-38734882

RESUMEN

BACKGROUND The rarity of ischiopagus tripus conjoined twins complicates the surgical separation, owing to the lack of cases and high complexity. We aim to report our experience in performing orthopedic correction for ischiopagus tripus twins. CASE REPORT A pair of 3-year-old conjoined boys presented with a fused body at the pelvis region and only 1 umbilicus. There were 2 legs separated by shared genitalia and an anus at the midline, and 1 fused leg, which could be felt and moved by both of the patients. The twins also shared internal organs of the bladder, intestine, and rectum, as visualized through angiography computerized tomography scan. After several team discussions with the institutional review board, the hospital ethics committee, and both parents, it was agreed to perform disarticulation of the fused third limb, followed by correction of the trunk alignment by pelvic closed wedge osteotomy and internal fixation. We successfully reconstructed the pelvis using locking plates and additional 3.5-mm cortical screws and 1.2-mm stainless steel wire. CONCLUSIONS This report describes the presentation and surgical management of a case of ischiopagus tripus conjoined twins. It highlights the challenges involved in surgery and the importance of investigating these infants for other congenital abnormalities. Although surgical approaches for different sets of twins should be individually tailored, interventions aimed to provide optimal outcomes should consider ethical issues and parental/patient expectations. Even in situations in which the twins are inseparable, there is still room for surgical correction to be performed.


Asunto(s)
Gemelos Siameses , Humanos , Gemelos Siameses/cirugía , Masculino , Preescolar , Calidad de Vida , Osteotomía/métodos , Huesos Pélvicos/cirugía , Huesos Pélvicos/anomalías , Isquion/anomalías , Isquion/cirugía , Pelvis/anomalías , Pelvis/cirugía
5.
BMC Geriatr ; 24(1): 314, 2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38575871

RESUMEN

BACKGROUND AND OBJECTIVES: It is known that difficulty sleeping after a fracture can have negative effects on both mental and physical health and may prolong the recovery process. The objective of this study is to explore how sleep quality and psychological health are linked in patients with pelvic and acetabulum fractures. METHODS: A study was conducted on 265 patients between 2018 and 2022 who had suffered pelvic and acetabulum fractures. The study examined various factors, including age, gender, cause of injury, post-operative complications, and injury severity. The study employed ordinal logistic regression to examine the relationship between various pelvic fractures and seven subscales of the Majeed Pelvic Score (MPS), as well as the Sleep Disorder Questionnaire (SDQ) and Beck Depression Inventory (BDI). The study focused on the postoperative outcome one year after surgery, and each patient was assessed at the one-year mark after surgical intervention. Additionally, the study evaluated the functional outcome, sleep quality, and psychological disorders of the patients. RESULTS: From 2018 to 2022, a total of 216 patients suffered from pelvic and acetabulum fractures. Among them, 6.6% experienced borderline clinical depression, and 45.2% reported mild mood disturbances. Anxiety was found to be mild to moderate in 46% of Tile C and posterior acetabulum wall fracture patients. About 24.8% of patients reported insomnia, while 23.1% reported sleep movement disorders. However, no significant correlation was found between fracture types and sleep disorders. The mean Majeed pelvic score (MPS) was 89.68. CONCLUSIONS: Patients with pelvic and acetabular fractures typically experience functional improvement, but may also be at increased risk for insomnia and sleep movement disorders, particularly for certain types of fractures. Psychological well-being varies between fracture groups, with signs of borderline clinical depression observed in some cases. However, anxiety levels do not appear to be significantly correlated with pelvic and acetabular fractures.


Asunto(s)
Fracturas Óseas , Fracturas de Cadera , Trastornos del Movimiento , Huesos Pélvicos , Trastornos del Inicio y del Mantenimiento del Sueño , Fracturas de la Columna Vertebral , Humanos , Acetábulo/lesiones , Estudios Transversales , Calidad del Sueño , Fracturas Óseas/complicaciones , Fracturas Óseas/epidemiología , Fracturas Óseas/cirugía , Huesos Pélvicos/cirugía , Huesos Pélvicos/lesiones , Estudios Retrospectivos
6.
Zhonghua Zhong Liu Za Zhi ; 46(4): 344-353, 2024 Apr 23.
Artículo en Chino | MEDLINE | ID: mdl-38644270

RESUMEN

Objective: To analyze the prognostic factors and the influence of surgical margin to prognosis. Methods: A retrospective analysis was performed for 208 pelvic tumors who received surgical treatment from January 2000 to December 2017 in our instituition. Survival analysis was performed using the Kaplan-Meier method and Log rank test, and impact factor analysis was performed using Cox regression models. Results: There were 183 initial patients and 25 recurrent cases. According to Enneking staging, 110 cases were stage ⅠB and 98 cases were stage ⅡB. 19 lesions were in zone Ⅰ, 1 in zone Ⅱ, 15 in zone Ⅲ, 29 in zone Ⅰ+Ⅱ, 71 in zone Ⅱ+Ⅲ, 29 in zone Ⅰ+Ⅳ, 35 in zone Ⅰ+Ⅱ+Ⅲ, 3 in zone Ⅰ+Ⅱ+Ⅳ, and 6 in zone Ⅰ+Ⅱ+Ⅲ+Ⅳ. Surgical margins including Intralesional excision in 7 cases, contaminated margin in 21 cases, marginal resection in 67 cases, and wide resection in 113 cases. Local recurrence occurred in 37 cases (17.8%), 25 cases were performed by reoperation and 12 cases received amputation finally. The 5-year recurrence rate of marginal resection was higher than wide resection (P<0.05), and the recurrence-free survival rate of marginal resection was lower than wide resection (P<0.05). There was significant differences in recurrence rate and recurrence-free survival rate between R0 and R1 resection (P<0.05). 92 cases were not reconstructed and 116 cases were reconstructed after pelvic surgery. At the last follow-up, 63 patients (30.3%) died, and the 5-year, 10-year and 15-year survival rates were 70.4%, 66.8% and 61.3%, respectively. The 5-year survival rate of stage ⅠB and ⅡB tumor was 90.4% and 46.8%, respectively. There were 29 cases had postoperative wound complications (13.8%), 1 case with pelvic organ injury. The final function was evaluated in 132 patients, with an average MSTS score of 25.1±3.6. Cox multivariate analysis showed that surgical staging, R0/R1 margin and metastasis were independent prognostic factors for pelvic tumors. Conclusions: The safe surgical margin is the key factor for recurrence-free of pelvic tumor. The survival rate of stage ⅡB pelvic tumors was significantly lower than that of stage ⅠB tumors. Wound infection is the main postoperative complication. Surgical staging, R0/R1 margin and metastasis were independent prognostic factors of pelvic tumors.


Asunto(s)
Neoplasias Óseas , Márgenes de Escisión , Recurrencia Local de Neoplasia , Huesos Pélvicos , Humanos , Estudios Retrospectivos , Huesos Pélvicos/cirugía , Neoplasias Óseas/cirugía , Pronóstico , Tasa de Supervivencia , Estadificación de Neoplasias , Modelos de Riesgos Proporcionales , Femenino , Reoperación , Masculino , Neoplasias Pélvicas/cirugía , Neoplasias Pélvicas/patología
7.
BMC Surg ; 24(1): 105, 2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38614998

RESUMEN

BACKGROUND: Most 3D-printed guiding templates require dissection of soft tissues to match the corresponding surfaces of the guiding templates. This study sought to explore the accuracy and acceptability of the novel 3D printed individualized guiding templates based on cutaneous fiducial markers in minimally invasive screw placement for pelvic fractures. METHODS: The printed template was tested on five high-fidelity biomimetic phantom models of the bony pelvis and its surrounding soft tissues as well as on two fresh frozen cadavers. Four cutaneous fiducial markers were transfixed on each phantom model prior to performing CT scans to reconstruct their 3D models. Personalized templates for guiding screw insertion were designed based on the positions of the fiducial markers and virtually planned target screw channels after scanning, followed by 3D printing of the guide. Phase 1 consisted of five expert surgeons inserting one anterograde supra-pubic screw and one sacroiliac screw percutaneously into each phantom model using the 3D-printed guide. The deviation of screw positions between the pre-operative planned and post-operative actual ones was measured after registering their 3D modelling. A Likert scale questionnaire was completed by the expert surgeons to assess their satisfaction and acceptability with the guiding template. Phase 2 consisted of repeating the same procedures on the fresh frozen cadavers in order to demonstrate face, content and concurrent validity. RESULTS: In Phase 1, all ten screws were successfully implanted with the assistance of the guiding template. Postoperative CT scans confirmed that all screws were safely positioned within the bony pelvic channels without breaching the far cortex. The mean longitudinal deviation at the bony entry point and screw tip between the pre-operative planned and post-operative actual screw paths were 2.83 ± 0.60 mm and 3.12 ± 0.81 mm respectively, with a mean angular deviation of 1.25 ± 0.41°. Results from the Likert questionnaire indicated a high level of satisfaction for using the guiding template among surgeons. In Phase 2, results were similar to those in Phase 1. CONCLUSIONS: The 3D-printed guiding template based on cutaneous fiducial markers shows potential for assisting in the accurate insertion of percutaneous screws in the pelvis.


Asunto(s)
Huesos Pélvicos , Cirujanos , Humanos , Marcadores Fiduciales , Pelvis , Huesos Pélvicos/diagnóstico por imagen , Huesos Pélvicos/cirugía , Cadáver
8.
Sci Rep ; 14(1): 9544, 2024 04 25.
Artículo en Inglés | MEDLINE | ID: mdl-38664538

RESUMEN

To compare the biomechanical properties of several anterior pelvic ring external fixators with two new configurations in the treatment of Tile C pelvic fractures, in order to evaluate the effectiveness of the new configurations and provide a reference for their clinical application. A finite element model of a Tile C pelvic ring injury (unilateral longitudinal sacral fracture and ipsilateral pubic fracture) was constructed. The pelvis was fixed with iliac crest external fixator (IC), anterior inferior iliac spine external fixator (AIIS), combination of IC and AIIS, combination of anterior superior iliac spine external fixator (ASIS) and AIIS, and S1 sacroiliac screw in 5 types of models. The stability indices of the anterior and posterior pelvic rings under vertical longitudinal load, left-right compression load and anterior-posterior shear load were quantified and compared. In the simulated bipedal standing position, the results of the vertical displacement of the midpoint on the upper surface of the sacrum are consistent with the displacement of the posterior rotation angle, and the order from largest to smallest is IC, AIIS, ASIS + AIIS, IC + AIIS and S1 screw. The longitudinal displacement of IC is greater than that of the other models. The displacements of ASIS + AIIS and IC + AIIS are similar and the latter is smaller. In the simulated semi-recumbent position, the vertical displacement and posterior rotation angle displacement of the midpoint on the upper surface of the sacrum are also consistent, ranking from large to small: IC, AIIS, ASIS + AIIS, IC + AIIS and S1 screw. Under the simulated left-right compression load state, the lateral displacements of the highest point of the lateral sacral fracture end are consistent with the highest point of the lateral pubic fracture end, and the order from large to small is S1 screw, IC, AIIS, ASIS + AIIS and IC + AIIS, among which the displacements of S1 screw and IC are larger, and the displacements of ASIS + AIIS and IC + AIIS are similar and smaller than those of other models. The displacements of IC + AIIS are smaller than those of ASIS + AIIS. Under the simulated anterior-posterior shear load condition, the posterior displacements of the highest point of the lateral sacral fracture end and the highest point of the lateral pubic fracture end are also consistent, ranking from large to small: IC, AIIS, ASIS + AIIS, IC + AIIS and S1 screw. Among them, the displacements of IC and AIIS are larger. The displacements of ASIS + AIIS and IC + AIIS are similar and the latter are smaller. For the unstable pelvic injury represented by Tile C pelvic fracture, the biomechanical various stabilities of the combination of IC and AIIS are superior to those of the external fixators of conventional configurations. The biomechanical stabilities of the combination of ASIS and AIIS are also better than those of the external fixators of conventional configurations, and slightly worse than those of the combination of IC and AIIS. Compared with sacroiliac screw and conventional external fixators, the lateral stabilities of IC + AIIS and ASIS + AIIS are particularly prominent.


Asunto(s)
Fijadores Externos , Fracturas Óseas , Huesos Pélvicos , Humanos , Fenómenos Biomecánicos , Huesos Pélvicos/lesiones , Huesos Pélvicos/cirugía , Fracturas Óseas/cirugía , Fijación de Fractura/métodos , Fijación de Fractura/instrumentación , Análisis de Elementos Finitos , Sacro/lesiones , Sacro/cirugía , Tornillos Óseos
9.
J Orthop Surg Res ; 19(1): 271, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38689343

RESUMEN

BACKGROUND: Precise and minimally invasive closed reduction is the premise of minimally invasive internal fixation. This paper aims to explore the safety and efficacy of a robot-assisted fracture reduction system (RAFR) in the treatment of pelvic fractures and to analyze its clinical advantages and existing problems. METHODS: The RAFR system intelligently designed the optimal reduction path and target position based on a preoperative three-dimensional(3D) CT scan of the patient. The reduction robotic arm automatically reduced the affected hemipelvis according to the pre-planned reduction path. RESULTS: The average residual displacement was the 6.65 ± 3.59 mm. According to Matta's criteria, there were 7 excellent, 10 good, and 3 fair, and the excellent and good rate was 85%. No postoperative complications occurred. CONCLUSION: In our study, the RAFR system could complete accurate and minimally invasive closed reduction for most patients with unstable pelvic fractures, which could achieve good fracture reduction quality and short-term efficacy.


Asunto(s)
Fracturas Óseas , Huesos Pélvicos , Procedimientos Quirúrgicos Robotizados , Humanos , Huesos Pélvicos/lesiones , Huesos Pélvicos/cirugía , Huesos Pélvicos/diagnóstico por imagen , Fracturas Óseas/cirugía , Fracturas Óseas/diagnóstico por imagen , Procedimientos Quirúrgicos Robotizados/métodos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Adulto Joven , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Anciano
10.
Sci Rep ; 14(1): 9747, 2024 04 28.
Artículo en Inglés | MEDLINE | ID: mdl-38679649

RESUMEN

The study aimed to explore an extra-articular screw placement strategy in Stoppa approach. Radiographic data of patients who underwent pelvic computed tomography from January 2016 to June 2017 were imported into Materiaise's interactive medical image control system software for three-dimensional reconstruction. Superior and lower margins of acetabulum and ipsilateral pelvic brim could be observed simultaneously through inlet-obturator view. A horizontal line from superior acetabular margin intersected pelvic brim at point "A" and another vertical line from lower margin intersected pelvic brim at point "B" were drawn, respectively. Lengths form sacroiliac joint to "A" (a), "A" to "B" (b), and "B" to pubic symphysis (c) were measured. Patients were divided into four groups depending on gender and side difference of measured hemi-pelvis: male left, male right, female left, and female right. Lengths of adjacent holes (d) and spanning different holes (e) of different plates were also measured. Mean lengths of a, b, c in four groups were 40.94 ± 1.85 mm, 40.09 ± 1.93 mm, 41.78 ± 3.62 mm, and 39.77 ± 2.23 mm (P = 0.078); 40.65 ± 1.58 mm, 41.48 ± 1.64 mm, 40.40 ± 1.96 mm, and 40.66 ± 1.70 mm (P = 0.265); 57.03 ± 3.41 mm, 57.51 ± 3.71 mm, 57.84 ± 4.40 mm, and 59.84 ± 4.35 mm (P = 0.165), respectively. Mean d length of different plates was 12.23 mm. Average lengths spanning 1, 2, 3 and 4 holes were 19.33 mm, 31.58 mm, 43.80 mm, and 55.93 mm. Our data showed that zones a and c could be safely inserted three and four screws. Penetration into hip joint could be avoided when vacant 3-hole drilling was conducted in zone b. Fracture line in zone b could serve as a landmark for screw placement.


Asunto(s)
Tornillos Óseos , Imagenología Tridimensional , Tomografía Computarizada por Rayos X , Humanos , Femenino , Masculino , Imagenología Tridimensional/métodos , Persona de Mediana Edad , Adulto , Fijación Interna de Fracturas/métodos , Anciano , Huesos Pélvicos/cirugía , Huesos Pélvicos/diagnóstico por imagen , Acetábulo/cirugía , Acetábulo/diagnóstico por imagen , Articulación Sacroiliaca/cirugía , Articulación Sacroiliaca/diagnóstico por imagen , Fracturas Óseas/cirugía , Fracturas Óseas/diagnóstico por imagen
11.
Artículo en Inglés | MEDLINE | ID: mdl-38447560

RESUMEN

PURPOSE OF THE STUDY: Pelvic reconstructions after massive bone resections are among the most challenging practices in orthopedic surgery. Whether the bone gap results after a trauma, a tumor resection, or it is due to a prosthetic revision, it is mandatory to reconstruct pelvic bone continuity and rebuild the functional thread that connects spine and hip joint. Several different approaches have been described in literature through the decades to achieve those goals. MATERIAL AND METHODS: To this date, 3D-printed implants represent one of the most promising surgical technologies in orthopedic oncology and complex reconstructive surgery. We present our experience with 3D-printed custom-made pelvic prostheses to fulfi ll bone gaps resulting from massive bone loss due to tumor resections. We retrospectively evaluated 17 cases treated with pelvic bone reconstruction using 3D-printed prostheses. Cases were evaluated in terms of both oncological and functional outcomes. RESULTS: At the last follow-up, local complications were found in 6 cases (36%): in 4 (23.5%) of them the cause was a local recurrence of the disease, whereas only 2 (12.5%) had non-oncologic issues. The mean MSTS score in our population increased from 8.2 before surgery to 22.3 at the latest clinical control after surgery. DISCUSSION: 3D-printing technology, used to produce cutting jigs and prosthetic implants, can lead to good clinical and functional outcomes. These encouraging results are comparable with the ones obtained with other more frequently used reconstructive approaches and support custom-made implants as a promising reconstructive approach. CONCLUSIONS: Our data confi rm 3D-printing and custom-made implants as promising technologies that could shape the next future of orthopedic oncology and reconstructive surgery. KEY WORDS: custom made prosthesis, pelvic reconstruction, orthopedic oncology, cutting jigs, 3D-printing.


Asunto(s)
Neoplasias , Huesos Pélvicos , Humanos , Estudios Retrospectivos , Impresión Tridimensional , Tecnología , Huesos Pélvicos/cirugía , Artrodesis
12.
Ann Surg Oncol ; 31(5): 3280-3299, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38459419

RESUMEN

BACKGROUND: Extended pelvic surgery with neurovascular or bony resections in gynecological oncology has significant impact on quality of life (QoL) and high morbidity. The objective of this systematic review was to provide an overview of QoL, morbidity and mortality following these procedures. METHODS: The registered PROSPERO protocol included database-specific search strategies. Studies from 1966 onwards reporting on QoL after extended pelvic surgery with neurovascular or bony resections for gynecological cancer were considered eligible. All others were excluded. Study selection (Rayyan), data extraction, rating of evidence (GRADE) and risk of bias (ROBINS-I) were performed independently by two reviewers. RESULTS: Of 349 identified records, 121 patients from 11 studies were included-one prospective study, seven retrospective studies, and three case reports. All studies were of very low quality and with an overall serious risk of bias. Primary tumor location was the cervix (n = 78, 48.9%), vulva (n = 30, 18.4%), uterus (n = 21, 12.9%), endometrium (n = 15, 9.2%), ovary (n = 8, 4.9%), (neo)vagina (n = 3, 1.8%), Gartner duct/paracolpium (n = 1, 0.6%), or synchronous tumors (n = 3, 1.8%), or were not reported (n = 4, 2.5%). Bony resections included the pelvic bone (n = 36), sacrum (n = 2), and transverse process of L5 (n = 1). Margins were negative in 70 patients and positive in 13 patients. Thirty-day mortality was 1.7% (2/121). Three studies used validated QoL questionnaires and seven used non-validated measurements; all reported acceptable QoL postoperatively. CONCLUSIONS: In this highly selected patient group, mortality and QoL seem to be acceptable, with a high morbidity rate. This comprehensive study will help to inform eligible patients about the outcomes of extended pelvic surgery with neurovascular or bony resections. Future collaborative studies can enable the collection of QoL data in a validated, uniform manner.


Asunto(s)
Huesos Pélvicos , Calidad de Vida , Femenino , Humanos , Estudios Retrospectivos , Estudios Prospectivos , Huesos Pélvicos/cirugía , Sacro/cirugía
13.
J Mech Behav Biomed Mater ; 153: 106488, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38437754

RESUMEN

INTRODUCTION: This systematic review aims to identify previously used techniques in biomechanics to assess pelvic instability following pelvic injury, focusing on external fixation constructs. METHODS: A systematic literature search was conducted to include biomechanical studies and to exclude clinical trials. RESULTS: Of an initial 4666 studies found, 38 met the inclusion criteria. 84% of the included studies were retrieved from PubMed, Scopus, and Web of Science. The studies analysed 106 postmortem specimens, 154 synthetic bones, and 103 computational models. Most specimens were male (97% synthetic, 70% postmortem specimens). Both the type of injury and the classification system employed varied across studies. About 82% of the injuries assessed were of type C. Two different fixators were tested for FFPII and type A injury, five for type B injury, and fifteen for type C injury. Large variability was observed for external fixation constructs concerning device type and configuration, pin size, and geometry. Biomechanical studies deployed various methods to assess injury displacement, deformation, stiffness, and motion. Thereby, loading protocols differed and inconsistent definitions of failure were determined. Measurement techniques applied in biomechanical test setups included strain gauges, force transducers, and motion tracking techniques. DISCUSSION AND CONCLUSION: An ideal fixation method should be safe, stable, non-obstructive, and have low complication rates. Although biomechanical testing should ensure that the load applied during testing is representative of a physiological load, a high degree of variability was found in the current literature in both the loading and measurement equipment. The lack of a standardised test design for fixation constructs in pelvic injuries across the studies challenges comparisons between them. When interpreting the results of biomechanical studies, it seems crucial to consider the limitations in cross-study comparability, with implications on their applicability to the clinical setting.


Asunto(s)
Fracturas Óseas , Huesos Pélvicos , Humanos , Fenómenos Biomecánicos , Fijadores Externos , Fijación de Fractura/métodos , Huesos Pélvicos/cirugía
14.
Arch Orthop Trauma Surg ; 144(5): 2381-2389, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38554208

RESUMEN

INTRODUCTION: This study aimed to investigate the accuracy of cup position and assess the changes in pelvic tilt during primary total hip arthroplasty (THA) in the lateral decubitus position using a new computed tomography (CT)-based navigation system with augmented reality (AR) technology. MATERIALS AND METHODS: There were 37 cementless THAs performed using a CT-based navigation system with AR technology in the lateral decubitus position and 63 cementless THAs performed using manual implant techniques in the lateral decubitus position in this retrospective study. Postoperative cup radiographic inclination and anteversion were measured using postoperative CT, and the proportion of hips within Lewinnek's safe zone was analyzed and compared between the two groups. The mean absolute values of navigation error were assessed. Intraoperative pelvic tilt angles were also recorded using navigation system. RESULTS: The percentage of cups inside Lewinnek's safe zone was 100% in the navigation group and 35% in the control group (p < 0.001). The mean absolute values of navigation error in inclination and anteversion were 2.9° ± 2.1° and 3.3° ± 2.4°, respectively. The mean abduction angle of the pelvis was 5.1° ± 4.8° after placing the patients in the lateral decubitus position and 4.1° ± 6.0° after cup placement. The mean posterior tilt angle was 6.8° ± 5.1° after placing the patients in the lateral decubitus position and 9.3° ± 5.9° after cup placement. The mean internal rotation angle was 14.8° ± 7.4° after cup placement. There were no correlations between the navigation error in inclination or anteversion and the absolute values of changes of the pelvic tilt angle at any phase. CONCLUSIONS: Although progressive pelvic motion occurred in THA in the lateral decubitus position, especially during cup placement, the CT-based navigation system with AR technology improved cup placement accuracy.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Posicionamiento del Paciente , Tomografía Computarizada por Rayos X , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Cadera/instrumentación , Femenino , Masculino , Tomografía Computarizada por Rayos X/métodos , Estudios Retrospectivos , Persona de Mediana Edad , Anciano , Posicionamiento del Paciente/métodos , Prótesis de Cadera , Realidad Aumentada , Sistemas de Navegación Quirúrgica , Cirugía Asistida por Computador/métodos , Pelvis/diagnóstico por imagen , Huesos Pélvicos/diagnóstico por imagen , Huesos Pélvicos/cirugía
15.
Eur J Orthop Surg Traumatol ; 34(4): 2205-2211, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38554164

RESUMEN

Pelvic fixation is commonly used in correcting pelvic obliquity in pediatric patients with neuromuscular scoliosis and in preserving stability in adult patients with lumbosacral spondylolisthesis or instances of traumatic or osteoporotic fracture. S2-alar-iliac screws are commonly used in this role and have been proposed to reduce implant prominence when compared to traditional pelvic fusion utilizing iliac screws. The aim of this technical note is to describe a technique for robotically navigated placement of S2-alar-iliac screws in pediatric patients with neuromuscular scoliosis, which (a) minimizes the significant exposure needed to identify a bony start point, (b) aids in instrumenting the irregular anatomy often found in patients with neuromuscular scoliosis, and (c) allows for greater precision than traditional open or fluoroscopic techniques. We present five cases that underwent posterior spinal fusion to the pelvis with this technique that demonstrate the safety and efficacy of this procedure.


Asunto(s)
Tornillos Óseos , Procedimientos Quirúrgicos Robotizados , Escoliosis , Fusión Vertebral , Humanos , Escoliosis/cirugía , Fusión Vertebral/métodos , Fusión Vertebral/instrumentación , Procedimientos Quirúrgicos Robotizados/métodos , Procedimientos Quirúrgicos Robotizados/instrumentación , Femenino , Niño , Adolescente , Masculino , Ilion/cirugía , Huesos Pélvicos/cirugía , Huesos Pélvicos/diagnóstico por imagen , Huesos Pélvicos/lesiones , Sacro/cirugía , Sacro/diagnóstico por imagen , Enfermedades Neuromusculares/complicaciones , Enfermedades Neuromusculares/cirugía , Vértebras Lumbares/cirugía , Vértebras Lumbares/diagnóstico por imagen , Cirugía Asistida por Computador/métodos
16.
Eur J Orthop Surg Traumatol ; 34(4): 2107-2112, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38548873

RESUMEN

BACKGROUND: Minimally invasive percutaneous screw fixation for pelvic ring and acetabular fractures has become increasingly popular due to its numerous benefits. However, the precise placement of the screw remains a critical challenge, necessitating a modification of the current techniques. This paper introduces a refined technique employing a modified guidewire to enhance the precision and efficiency of percutaneous fixation in pelvic and acetabular fractures. METHODS: This study details the surgical techniques implemented for correcting guidewire misdirection in percutaneous screw fixation and includes a retrospective analysis of patients treated with this modified approach over a three-year period. RESULTS: In this study, 25 patients with pelvic ring and acetabular fractures underwent percutaneous screw fixation. The cohort, predominantly male (23 out of 25), had an average age of 38 years. The majority of injuries were due to traffic accidents (18 out of 25). Types of injuries included pelvic ring (6 cases), acetabular fractures (8 cases), and combined injuries (11 cases). Various screw types, including antegrade and retrograde anterior column screws, retrograde posterior column screws, and lateral compression screws, were used, tailored to each case. Over an average follow-up of 18 months, there were no additional procedures or complications, such as neurovascular injury or hardware failure, indicating successful outcomes in all cases. CONCLUSIONS: This study introduces a simple yet effective method to address guidewire misdirection during percutaneous fixation for pelvic and acetabular fractures, offering enhanced precision and potentially better patient outcomes. Further research with a larger patient cohort is required for a more comprehensive understanding of its efficacy compared to traditional methods. LEVEL OF EVIDENCE: IV. Therapeutic Study (Surgical technique and Cases-series).


Asunto(s)
Acetábulo , Tornillos Óseos , Fijación Interna de Fracturas , Fracturas Óseas , Huesos Pélvicos , Humanos , Acetábulo/lesiones , Acetábulo/cirugía , Masculino , Huesos Pélvicos/lesiones , Huesos Pélvicos/cirugía , Adulto , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/efectos adversos , Femenino , Fracturas Óseas/cirugía , Estudios Retrospectivos , Persona de Mediana Edad , Adulto Joven , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Resultado del Tratamiento , Hilos Ortopédicos
17.
Eur J Orthop Surg Traumatol ; 34(4): 1917-1925, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38459970

RESUMEN

INTRODUCTION: Pelvic ring fractures, particularly those involving the posterior pelvis, pose significant challenges due to their inherent instability. The posterior pelvic ring is critical in providing structural support and stability to the pelvis. This study evaluates the functional outcomes and health-related Quality of life (HRQOL) of patients who underwent internal fixation for unstable pelvic fractures. Various factors influencing the outcomes are also investigated. MATERIAL AND METHODS: A single-center cross-sectional study was conducted on patients with unstable sacral fractures treated with posterior tension band plate or sacroiliac plating with or without symphyseal plating between 2016 and 2020. Patient demographics, injury mechanisms, associated injuries, surgical details, complications, and return-to-work data were collected. HRQOL was assessed using specific pelvic fracture instruments and general HRQOL questionnaires. Logistic regression analysis was performed to identify factors associated with lower SF-12 and SF-36 scores RESULTS: The study included 54 patients, predominantly males (55.6%), aged 18-70 years, with high-energy trauma mechanisms, such as road traffic accidents and occupational injuries. The majority of patients had lateral compression pelvic fractures. Overall, the functional outcomes were favorable, with excellent or good outcomes observed in 86.1% of cases. Patients with associated injuries, such as abdominal, chest, or head injuries, were likelier to have lower SF-12 physical component scores. Sexual satisfaction scores remained stable for most patients post-surgery. DISCUSSION: This study highlights the favorable functional outcomes and HRQOL for patients undergoing fixation for unstable pelvic ring fractures. Younger, working-age males were the most commonly affected demographic. Associated injuries significantly affected physical HRQOL scores. Despite high-energy trauma, patients generally reported satisfactory sexual function post-surgery.


Asunto(s)
Fijación Interna de Fracturas , Fracturas Óseas , Huesos Pélvicos , Calidad de Vida , Humanos , Masculino , Estudios Transversales , Huesos Pélvicos/lesiones , Huesos Pélvicos/cirugía , Persona de Mediana Edad , Femenino , Adulto , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/efectos adversos , Fracturas Óseas/cirugía , Fracturas Óseas/psicología , Anciano , Adolescente , Adulto Joven , Placas Óseas , Resultado del Tratamiento , Recuperación de la Función
18.
Orthop Surg ; 16(4): 989-997, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38389215

RESUMEN

OBJECTIVE: Closed reduction of pelvic injuries is a prerequisite and critical step in minimally invasive treatment. Achieving non-invasive closed reduction of pelvic injuries is a challenging clinical problem. This study demonstrated a non-invasive traction technique for closed reduction called countertraction closed reduction technique (CCRT) and evaluated its effectiveness for type C pelvic ring injuries. METHOD: The data of patients with unstable pelvic fractures treated with CCRT and minimally invasive fixation were retrospectively reviewed from January 2017 to February 2022. Sacroiliac screws were placed to fix the posterior pelvic ring, and internal or external fixation was used to fix the anterior pelvic ring. Operation time, intraoperative blood loss, duration of hospital stay, fracture union and postoperative complications were recorded. Fracture reduction quality was evaluated using the Matta scoring criteria. Functional recovery and general quality of life were evaluated using the Majeed functional scoring criteria. RESULTS: Thirteen patients (nine males and four females), with an average age of 49.6 years were treated with CCRT and followed up for a mean of 18.5 months. The average operation time was 137.2 minutes (range 92-195 minutes), the average intraoperative blood loss was 31.2 mL (range 10-120 mL) and the average duration of hospital stay was 14.3 days (range 4-32 days). All patients achieved bony union with an average union time of 11.9 weeks (range 10-16 weeks). According to the Matta radiographic criteria, the quality of fracture reduction was excellent in eight patients, good in four, and fair in one. The average Majeed functional score was 89.7 (range 78-100). The functional evaluation revealed that the outcomes were excellent in nine patients, and good in four patients. Complications included incision fat liquefaction in one patient, and heterotopic ossification in another patient. There were no surgical complications as a result of CCRT. CONCLUSION: CCRT is a non-invasive closed reduction method for minimally invasive fixation of fresh Tile C1 and C2 pelvic fractures. The advantages of CCRT combined with minimally invasive treatment include a small surgical incision, reduced intraoperative bleeding, satisfactory fracture reduction, bone healing and functional recovery.


Asunto(s)
Fracturas Óseas , Huesos Pélvicos , Masculino , Femenino , Humanos , Persona de Mediana Edad , Fijación Interna de Fracturas/métodos , Estudios Retrospectivos , Pérdida de Sangre Quirúrgica , Calidad de Vida , Fracturas Óseas/cirugía , Huesos Pélvicos/cirugía , Huesos Pélvicos/lesiones , Resultado del Tratamiento
19.
Arch Orthop Trauma Surg ; 144(4): 1627-1635, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38353686

RESUMEN

INTRODUCTION: From transiliac Harrington rods to minimally invasive (MIS) percutaneous 3D-navigated transsacral-transiliac screw (TTS) fixation, concepts of fixation methods in pelvic injuries with spinopelvic dissociation (SPD) are steadily redefined. This narrative review examines the literature of recent years regarding surgical treatment options and trends in SPD, outlining risks and benefits of each treatment option and addressing biomechanical aspects of sacral injuries and common classification systems. MATERIALS AND METHODS: A literature search on the search across relevant online databases was conducted. As a scale for quality assessment, the SANRA-scoring system was taken into account. RESULTS: Sacral Isler type 1 injuries of the LPJ in U- and H-type fractures are frequently treated with stand-alone TTS. Fractures with higher instability (Isler types 2 and 3) require unilateral or bilateral LPF, subject to side involvement, as a buttressing construct, or triangular fixation as additional compression and neutralization, determined by fracture radiation. A more comprehensive classification from which to derive stabilization options is provided by the 2023 301SPD classification. MIS techniques are on the rise and offer shorter OR time, less blood loss, fewer infections, and fewer wound complications. It is advisable to implement MIS techniques as much as possible, as long as decompression is not required and closed fracture reduction succeeds satisfactorily. CONCLUSION: SPD is characteristic of severe injuries, mostly in polytraumatized patients. The complication rates are decreasing due to the increasing adaptation of MIS techniques.


Asunto(s)
Fracturas Óseas , Huesos Pélvicos , Enfermedades de la Columna Vertebral , Fracturas de la Columna Vertebral , Humanos , Fracturas de la Columna Vertebral/cirugía , Fracturas de la Columna Vertebral/etiología , Fracturas Óseas/cirugía , Fracturas Óseas/etiología , Fijación Interna de Fracturas/métodos , Sacro/cirugía , Sacro/lesiones , Huesos Pélvicos/cirugía , Huesos Pélvicos/lesiones
20.
Int J Surg ; 110(5): 2636-2648, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38320104

RESUMEN

OBJECT: A novel technique, percutaneous elastic stable intramedullary nail fixation (ESIN), proposed by our team for the treatment of anterior pelvic ring injury. Finite element analysis and retrospective case-control study were used to compare biomechanical properties and clinical outcomes between ESIN and other techniques. METHODS: Four groups of finite element models of pelvic anterior ring injury were simulated, including ESIN (model A), retrograde transpubic screw fixation (RTSF, model B), subcutaneous internal fixator (model C), and external fixator (model D), and a vertical downward load of 500 N was applied to the S1 vertebral endplate. Stress and displacement distributions of intact pelvis, displacement distributions of pubic fracture fragments, and stress distributions of fixation devices were analysed. Then 31 patients with anterior pelvic ring injury (15 in the ESIN group and 16 in the RTSF group) were reviewed. Clinical outcomes were evaluated at the final follow-up. Postoperative complications were also recorded. RESULTS: Under 500N loading, the intact stability of the pelvis was compared as follows: model B (20.58 mm, 121.82 MPa), model A (20.80 mm, 129.97 MPa), model C (22.02 mm, 141.70 MPa), and model D (22.57 mm, 147.06 MPa). The regional stability of superior pubic ramus was compared as follows: model B (9.48 mm), model A (10.16 mm), model C (10.52 mm), and model D (10.76 mm). All 31 patients received follow-up at least 12 months postsurgery (range 12-20 months). Age, sex, injury mechanism, fracture type, time between the injury and operation, American Society of Anesthesiologists score, intraoperative blood loss, hospital stay, follow-up period, time to union, and Majeed scores did not differ significantly between the two groups ( P >0.05). However, the differences in the duration of unilateral surgery, unilateral intraoperative fluoroscopy and one-time success rate were significant ( P <0.05). CONCLUSIONS: With sufficient biomechanical stability and minimally invasive advantage, the percutaneous technique using ESIN can be used to successfully treat anterior pelvic ring injuries. In addition, advantages over RTSF include a shorter duration of surgery, reduced requirement for intraoperative fluoroscopy, and a higher one-time success rate. ESIN therefore constitutes a good alternative to RTSF.


Asunto(s)
Análisis de Elementos Finitos , Procedimientos Quirúrgicos Mínimamente Invasivos , Huesos Pélvicos , Humanos , Huesos Pélvicos/lesiones , Huesos Pélvicos/cirugía , Estudios de Casos y Controles , Masculino , Femenino , Adulto , Estudios Retrospectivos , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Fracturas Óseas/cirugía , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/instrumentación , Fenómenos Biomecánicos , Clavos Ortopédicos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...