Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.330
Filtrar
1.
Science ; 384(6696): eadm7168, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38723062

RESUMEN

Despite a half-century of advancements, global magnetic resonance imaging (MRI) accessibility remains limited and uneven, hindering its full potential in health care. Initially, MRI development focused on low fields around 0.05 Tesla, but progress halted after the introduction of the 1.5 Tesla whole-body superconducting scanner in 1983. Using a permanent 0.05 Tesla magnet and deep learning for electromagnetic interference elimination, we developed a whole-body scanner that operates using a standard wall power outlet and without radiofrequency and magnetic shielding. We demonstrated its wide-ranging applicability for imaging various anatomical structures. Furthermore, we developed three-dimensional deep learning reconstruction to boost image quality by harnessing extensive high-field MRI data. These advances pave the way for affordable deep learning-powered ultra-low-field MRI scanners, addressing unmet clinical needs in diverse health care settings worldwide.


Asunto(s)
Aprendizaje Profundo , Imagen por Resonancia Magnética , Imagen de Cuerpo Entero , Imagen por Resonancia Magnética/métodos , Imagen de Cuerpo Entero/métodos , Humanos , Imagenología Tridimensional/métodos
2.
Cancer Imaging ; 24(1): 57, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38711135

RESUMEN

BACKGROUND: PSMA PET/CT is a predictive and prognostic biomarker for determining response to [177Lu]Lu-PSMA-617 in patients with metastatic castration resistant prostate cancer (mCRPC). Thresholds defined to date may not be generalizable to newer image reconstruction algorithms. Bayesian penalized likelihood (BPL) reconstruction algorithm is a novel reconstruction algorithm that may improve contrast whilst preventing introduction of image noise. The aim of this study is to compare the quantitative parameters obtained using BPL and the Ordered Subset Expectation Maximization (OSEM) reconstruction algorithms. METHODS: Fifty consecutive patients with mCRPC who underwent [68Ga]Ga-PSMA-11 PET/CT using OSEM reconstruction to assess suitability for [177Lu]Lu-PSMA-617 therapy were selected. BPL algorithm was then used retrospectively to reconstruct the same PET raw data. Quantitative and volumetric measurements such as tumour standardised uptake value (SUV)max, SUVmean and Molecular Tumour Volume (MTV-PSMA) were calculated on both reconstruction methods. Results were compared (Bland-Altman, Pearson correlation coefficient) including subgroups with low and high-volume disease burdens (MTV-PSMA cut-off 40 mL). RESULTS: The SUVmax and SUVmean were higher, and MTV-PSMA was lower in the BPL reconstructed images compared to the OSEM group, with a mean difference of 8.4 (17.5%), 0.7 (8.2%) and - 21.5 mL (-3.4%), respectively. There was a strong correlation between the calculated SUVmax, SUVmean, and MTV-PSMA values in the OSEM and BPL reconstructed images (Pearson r values of 0.98, 0.99, and 1.0, respectively). No patients were reclassified from low to high volume disease or vice versa when switching from OSEM to BPL reconstruction. CONCLUSIONS: [68Ga]Ga-PSMA-11 PET/CT quantitative and volumetric parameters produced by BPL and OSEM reconstruction methods are strongly correlated. Differences are proportional and small for SUVmean, which is used as a predictive biomarker. Our study suggests that both reconstruction methods are acceptable without clinical impact on quantitative or volumetric findings. For longitudinal comparison, committing to the same reconstruction method would be preferred to ensure consistency.


Asunto(s)
Algoritmos , Teorema de Bayes , Isótopos de Galio , Radioisótopos de Galio , Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata Resistentes a la Castración , Humanos , Masculino , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Neoplasias de la Próstata Resistentes a la Castración/diagnóstico por imagen , Neoplasias de la Próstata Resistentes a la Castración/patología , Anciano , Persona de Mediana Edad , Estudios Retrospectivos , Oligopéptidos , Ácido Edético/análogos & derivados , Imagen de Cuerpo Entero/métodos , Radiofármacos , Anciano de 80 o más Años , Metástasis de la Neoplasia , Procesamiento de Imagen Asistido por Computador/métodos , Dipéptidos/uso terapéutico
3.
J Nucl Med ; 65(Suppl 1): 54S-63S, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38719233

RESUMEN

In recent decades, researchers worldwide have directed their efforts toward enhancing the quality of PET imaging. The detection sensitivity and image resolution of conventional PET scanners with a short axial field of view have been constrained, leading to a suboptimal signal-to-noise ratio. The advent of long-axial-field-of-view PET scanners, exemplified by the uEXPLORER system, marked a significant advancement. Total-body PET imaging possesses an extensive scan range of 194 cm and an ultrahigh detection sensitivity, and it has emerged as a promising avenue for improving image quality while reducing the administered radioactivity dose and shortening acquisition times. In this review, we elucidate the application of the uEXPLORER system at the Sun Yat-sen University Cancer Center, including the disease distribution, patient selection workflow, scanning protocol, and several enhanced clinical applications, along with encountered challenges. We anticipate that this review will provide insights into routine clinical practice and ultimately improve patient care.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Imagen de Cuerpo Entero , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Imagen de Cuerpo Entero/métodos , Neoplasias/diagnóstico por imagen , Centros de Atención Terciaria , Instituciones Oncológicas , Procesamiento de Imagen Asistido por Computador/métodos
4.
Semin Arthritis Rheum ; 66: 152437, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38564998

RESUMEN

Inter-reader reliability of a new scoring system for evaluating joint inflammation and enthesitis in whole body MRI (WBMRI) in juvenile idiopathic arthritis was tested. The scoring system grades 732 item-region combinations of bone marrow and soft tissue changes for commonly involved joints and entheseal sites. Five radiologists rated 17 WBMRI scans through an online rating platform. Item-wise reliability was calculated for 117 items with non-zero scores in >10 % of readings. Interquartile ranges of the five-reader Kappa reliability coefficients were 0.58-0.73 (range: 0.36-0.88) for the joints, 0.65-0.81 (range: 0.39-0.95) for the entheses, and 0.62-0.75 (range: 0.60-0.76) for chronic nonbacterial osteomyelitis-like lesions.


Asunto(s)
Artritis Juvenil , Imagen por Resonancia Magnética , Imagen de Cuerpo Entero , Humanos , Artritis Juvenil/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Reproducibilidad de los Resultados , Niño , Imagen de Cuerpo Entero/métodos , Masculino , Índice de Severidad de la Enfermedad , Femenino , Adolescente , Articulaciones/diagnóstico por imagen , Preescolar
5.
Neuroimage ; 293: 120611, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38643890

RESUMEN

Dynamic PET allows quantification of physiological parameters through tracer kinetic modeling. For dynamic imaging of brain or head and neck cancer on conventional PET scanners with a short axial field of view, the image-derived input function (ID-IF) from intracranial blood vessels such as the carotid artery (CA) suffers from severe partial volume effects. Alternatively, optimization-derived input function (OD-IF) by the simultaneous estimation (SIME) method does not rely on an ID-IF but derives the input function directly from the data. However, the optimization problem is often highly ill-posed. We proposed a new method that combines the ideas of OD-IF and ID-IF together through a kernel framework. While evaluation of such a method is challenging in human subjects, we used the uEXPLORER total-body PET system that covers major blood pools to provide a reference for validation. METHODS: The conventional SIME approach estimates an input function using a joint estimation together with kinetic parameters by fitting time activity curves from multiple regions of interests (ROIs). The input function is commonly parameterized with a highly nonlinear model which is difficult to estimate. The proposed kernel SIME method exploits the CA ID-IF as a priori information via a kernel representation to stabilize the SIME approach. The unknown parameters are linear and thus easier to estimate. The proposed method was evaluated using 18F-fluorodeoxyglucose studies with both computer simulations and 20 human-subject scans acquired on the uEXPLORER scanner. The effect of the number of ROIs on kernel SIME was also explored. RESULTS: The estimated OD-IF by kernel SIME showed a good match with the reference input function and provided more accurate estimation of kinetic parameters for both simulation and human-subject data. The kernel SIME led to the highest correlation coefficient (R = 0.97) and the lowest mean absolute error (MAE = 10.5 %) compared to using the CA ID-IF (R = 0.86, MAE = 108.2 %) and conventional SIME (R = 0.57, MAE = 78.7 %) in the human-subject evaluation. Adding more ROIs improved the overall performance of the kernel SIME method. CONCLUSION: The proposed kernel SIME method shows promise to provide an accurate estimation of the blood input function and kinetic parameters for brain PET parametric imaging.


Asunto(s)
Encéfalo , Tomografía de Emisión de Positrones , Humanos , Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones/normas , Encéfalo/diagnóstico por imagen , Imagen de Cuerpo Entero/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos
6.
Injury ; 55(5): 111494, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38521635

RESUMEN

BACKGROUND: Whole-Body CT (WBCT) is frequently used in emergency situations for promptly diagnosing paediatric polytrauma patients, given the challenges associated with obtaining precise details about the mechanism and progression of trauma. However, WBCT does not lead to reduced mortality in paediatric patients, but is associated with high radiation exposure. We therefore wanted to develop a screening tool for CT demand-driven emergency room (ER)-trauma diagnostic to reduce radiation exposure in paediatric patients. METHODS: A retrospective study in a Level I trauma centre in Germany was performed. Data from 344 paediatric emergency patients with critical mechanism of injury who were pre-announced by the ambulance for the trauma room were collected. Patients' symptoms, clinical examination, extended Focused Assessment with Sonography for Trauma (eFAST), routinely, laboratory tests and blood gas and - when obtained - WBCT images were analysed. To identify potential predictors of severe injuries (ISS > 23), 300 of the 344 cases with complete data were subjected to regression analyses model. RESULTS: Multiple regression analysis identified cGCS, base excess (BE), medically abnormal results from eFAST screening, initial unconsciousness, and injuries involving three or more body regions as significant predictors for a screening tool for decision-making to perform WBCT or selective CT. The developed Paediatric polytrauma CT-Indication (PePCI)-Score was divided into three risk categories and achieved a sensitivity of 87 % and a specificity of 71 % when comparing the low and medium risk groups with the high risk group. Comparing only the low-risk group with the high-risk group for the decision to perform WBCT, 32/35 (91 %) of patients with an ISS >23 were correctly identified, as were 124/137 (91 %) with lower ISS scores. CONCLUSION: With the newly developed PePCI-Score, the frequency of WBCT in a paediatric emergency patients collective can be significantly reduced according to our data. After prospective validation, the initial assessment of paediatric trauma patients in the future could be made not only by the mechanism of injury, but also by the new PePCI-Score, deriving on clinical findings after thorough clinical assessment and the discretion of the trauma team.


Asunto(s)
Traumatismo Múltiple , Imagen de Cuerpo Entero , Humanos , Niño , Estudios Retrospectivos , Pronóstico , Imagen de Cuerpo Entero/métodos , Tomografía Computarizada por Rayos X/métodos , Puntaje de Gravedad del Traumatismo
7.
Emerg Radiol ; 31(2): 251-268, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38396199

RESUMEN

Trauma is a significant cause of mortality and morbidity. It is crucial to diagnose trauma patients quickly to provide effective treatment interventions in such conditions. Whole-body computed tomography (WBCT)/pan-scan is an imaging technique that enables a faster and more efficient diagnosis for polytrauma patients. The purpose of this systematic review and meta-analysis is to evaluate the efficacy of WBCT in diagnosing injuries in polytrauma patients. We will also assess its impact on the mortality rate and length of hospital stay among trauma centers between patients who underwent WBCT and those who did not (non-WBCT). Twenty-seven studies meeting our inclusion criteria were selected among PubMed, Scopus, Web of Science, and Google Scholar. The criteria were centered on the significance of WBCT/pan-scan application in trauma patients. Stata version 15 was used to perform statistical analysis on the data. The authors have also used I2 statistics to evaluate heterogeneity. Egger and Begg's tests were performed to rule out any publication bias. Total of twenty-seven studies including 68,838 trauma patients with a mean age of 45.0 ± 24.7 years were selected. Motor vehicle collisions were the most common cause of blunt injuries (80.0%). Head, neck, and face injuries were diagnosed in 44% (95% CI, 0.28-0.60; I2 = 99.8%), 6% (95% CI, 0.02-0.09; I2 = 97.2%), and 9% (95% CI, 0.05-0.13; I2 = 97.1%), respectively. Chest injuries were diagnosed by WBCT in 39% (95% CI, 0.28-0.51; I2 = 99.8%), abdominal injuries in 23% (95% CI, 0.03-0.43; I2 = 99.9%) of cases, spinal injuries 19% (95% CI, 0.11-0.27; I2 = 99.4%), extremity injuries 33% (95% CI, 0.23-0.43; I2 = 99.2%), and pelvic injuries 11% (95% CI, 0.04-0.18; I2 = 97.4%). A mortality odd ratio of 0.94 (95% CI, 0.83-1.06; I2 = 40.1%) was calculated while comparing WBCT and non-WBCT groups. This systematic review and meta-analysis provide insight into the possible safety, efficacy, and efficiency of WBCT/pan-scan as a diagnostic tool for trauma patients with serious injuries, regardless of their hemodynamic status. In patients with serious injuries from trauma, whether or not there are indicators of hemodynamic instability, our recommended approach is to, wherever possible, perform a WBCT without stopping the hemostatic resuscitation. By using this technology, the optimal surgical strategy for these patients can be decided upon without causing any delays in their final care or greatly raising their radiation dose.


Asunto(s)
Traumatismo Múltiple , Traumatismos Torácicos , Heridas no Penetrantes , Humanos , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Traumatismo Múltiple/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Centros Traumatológicos , Imagen de Cuerpo Entero/métodos , Estudios Retrospectivos
8.
Clin Radiol ; 79(6): e791-e798, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38403540

RESUMEN

AIM: To evaluate arterial enhancement, its depiction, and image quality in low-tube potential whole-body computed tomography (CT) angiography (CTA) with extremely low iodine dose and compare the results with those obtained by hybrid-iterative reconstruction (IR) and deep-learning image-reconstruction (DLIR) methods. MATERIALS AND METHODS: This prospective study included 34 consecutive participants (27 men; mean age, 74.2 years) who underwent whole-body CTA at 80 kVp for evaluating aortic diseases between January and July 2020. Contrast material (240 mg iodine/ml) with simultaneous administration of its quarter volume of saline, which corresponded to 192 mg iodine/ml, was administered. CT raw data were reconstructed using adaptive statistical IR-Veo of 40% (hybrid-IR), DLIR with medium- (DLIR-M), and high-strength level (DLIR-H). A radiologist measured CT attenuation of the arteries and background noise, and the signal-to-noise ratio (SNR) was then calculated. Two reviewers qualitatively evaluated the arterial depictions and diagnostic acceptability on axial, multiplanar-reformatted (MPR), and volume-rendered (VR) images. RESULTS: Mean contrast material volume and iodine weight administered were 64.1 ml and 15.4 g, respectively. The SNRs of the arteries were significantly higher in the following order of the DLIR-H, DLIR-M, and hybrid-IR (p<0.001). Depictions of six arteries on axial, three arteries on MPR, and four arteries on VR images were significantly superior in the DLIR-M or hybrid-IR than in the DLIR-H (p≤0.009 for each). Diagnostic acceptability was significantly better in the DLIR-M and DLIR-H than in the hybrid-IR (p<0.001-0.005). CONCLUSION: DLIR-M showed well-balanced arterial depictions and image quality compared with the hybrid-IR and DLIR-H.


Asunto(s)
Angiografía por Tomografía Computarizada , Medios de Contraste , Aprendizaje Profundo , Dosis de Radiación , Imagen de Cuerpo Entero , Humanos , Masculino , Femenino , Anciano , Estudios Prospectivos , Angiografía por Tomografía Computarizada/métodos , Medios de Contraste/administración & dosificación , Imagen de Cuerpo Entero/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Algoritmos , Persona de Mediana Edad , Anciano de 80 o más Años , Enfermedades de la Aorta/diagnóstico por imagen
9.
Radiography (Lond) ; 30(2): 634-640, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38335690

RESUMEN

INTRODUCTION: Breast cancer is a common malignant tumor among women, and the effectiveness of diagnosing its metastasis and recurrence has been demonstrated using diffusion-weighted whole-body imaging with background body signal suppression (DWIBS). However, DWIBS causes distress to patients due to the unique circumstances of magnetic resonance imaging (MRI). This study aimed to investigate the various distress factors caused by DWIBS among women with breast cancer and assess the effectiveness of a new MRI system designed with an environment incorporating relaxing technology. METHODS: From May to September 2022, we conducted a questionnaire survey regarding DWIBS-related distress among women with breast cancer. The questionnaire was administered to participants who underwent DWIBS on a conventional MRI system (19 women) and on a new system (20 women) equipped with relaxing technology equipped features, including projection images, illumination, and sound. Participants rated the degree of various stress factors on a face-scale rating scale (0-10). The scores of both systems were compared using the Mann-Whitney U test. RESULTS: In the conventional system, women experienced distress due to MRI-specific situations, such as immobility in a confined space, noise, feeling trapped, and concerns about not moving. These results did not show a specific tendency among women with breast cancer undergoing DWIBS. For almost all distress parameters, the new system had significantly lower distress scores than the conventional system (p > 0.05). CONCLUSIONS: A comfortable environment using new and relaxing technology is effective in alleviating patient's anxiety by approaching the human senses. IMPLICATIONS FOR PRACTICE: Reducing distress caused by DWIBS among women with breast cancer could provide a comfortable examination environment, potentially assisting them during longer treatment periods.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Neoplasias de la Mama/diagnóstico , Imagen por Resonancia Magnética , Imagen de Cuerpo Entero/métodos , Sensibilidad y Especificidad , Ansiedad
10.
Cancer Imaging ; 24(1): 22, 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38326850

RESUMEN

BACKGROUND: Whole-body magnetic resonance imaging (WB-MRI) has emerged as a valuable tool for cancer detection. This study evaluated the prevalence rates of cancer in asymptomatic individuals undergoing WB-MRI according to the Oncologically Relevant Findings Reporting and Data System (ONCO-RADS) classifications in order to assess the reliability of the classification method. METHODS: We retrospectively enrolled 2064 asymptomatic individuals who participated in a WB-MRI cancer screening program between 2017 and 2022. WB-MRI was acquired on a 3-T system with a standard protocol, including regional multisequence and gadolinium-based contrast agent-enhanced oncologic MRI. Results of further examinations, including additional imaging and histopathology examinations, performed at our institute were used to validate the WB-MRI findings. Two radiologists blinded to the clinical outcome classified the WB-MRI findings according to the ONCO-RADS categories as follows: 1 (normal), 2 (benign finding highly likely), 3 (benign finding likely), 4 (malignant finding likely), and 5 (malignant finding highly likely). Firth logistic regression analysis was performed to determine the associations between participant characteristics and findings of ONCO-RADS category ≥ 4. RESULTS: Of the 2064 participants with median age of 55 years, 1120 (54.3%) were men, 43 (2.1%) had findings of ONCO-RADS category ≥ 4, and 24 (1.2%) had confirmed cancer. The cancer prevalence rates were 0.1%, 5.4%, 42.9%, and 75% for ONCO-RADS categories 2, 3, 4, and 5, respectively. In the multivariable model, older age (OR: 1.035, p = 0.029) and history of hypertension (OR: 2.051, p = 0.026), hepatitis B carrier (OR: 2.584, p = 0.013), or prior surgery (OR: 3.787, p < 0.001) were independently associated with the findings for ONCO-RADS category ≥ 4. CONCLUSIONS: The ONCO-RADS categories for cancer risk stratification were validated and found to be positively correlated with cancer risk. The application of ONCO-RADS facilitates risk-based management after WB-MRI for cancer screening.


Asunto(s)
Detección Precoz del Cáncer , Neoplasias , Masculino , Humanos , Persona de Mediana Edad , Femenino , Estudios Retrospectivos , Detección Precoz del Cáncer/métodos , Imagen por Resonancia Magnética/métodos , Reproducibilidad de los Resultados , Imagen de Cuerpo Entero/métodos , Neoplasias/diagnóstico por imagen , Neoplasias/epidemiología
11.
Semin Arthritis Rheum ; 65: 152384, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38325053

RESUMEN

OBJECTIVE: To develop a reference image atlas for the Outcome Measures in Rheumatology whole-body MRI scoring system for inflammation in peripheral joints and entheses (OMERACT MRI-WIPE) of the knee region. METHODS: Image examples of each pathology, location and grade, were collected and discussed at web-based, interactive meetings within the OMERACT MRI in Arthritis Working Group. Subsequently, reference images were selected by consensus. RESULTS: Reference images for each grade, pathology and location are depicted, along with definitions, reader rules and recommended MRI-sequences. CONCLUSION: The atlas guides scoring whole-body MRIs for inflammation in joints and entheses of the knee region according to MRI-WIPE methodology in clinical trials and cohorts.


Asunto(s)
Inflamación , Espondiloartritis , Humanos , Inflamación/diagnóstico por imagen , Espondiloartritis/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Imagen de Cuerpo Entero/métodos , Índice de Severidad de la Enfermedad , Reproducibilidad de los Resultados
12.
Clin Imaging ; 108: 110099, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38401295

RESUMEN

Whole-Body Magnetic Resonance Imaging (WB-MRI) has cemented its position as a pivotal tool in oncological diagnostics. It offers unparalleled soft tissue contrast resolution and the advantage of sidestepping ionizing radiation. This review explores the diverse applications of WB-MRI in oncology. We discuss its transformative role in detecting and diagnosing a spectrum of cancers, emphasizing conditions like multiple myeloma and cancers with a proclivity for bone metastases. WB-MRI's capability to encompass the entire body in a singular scan has ushered in novel paradigms in cancer screening, especially for individuals harboring hereditary cancer syndromes or at heightened risk for metastatic disease. Additionally, its contribution to the clinical landscape, aiding in the holistic management of multifocal and systemic malignancies, is explored. The article accentuates the technical strides achieved in WB-MRI, its myriad clinical utilities, and the challenges in integration into standard oncological care. In essence, this review underscores the transformative potential of WB-MRI, emphasizing its promise as a cornerstone modality in shaping the future trajectory of cancer diagnostics and treatment.


Asunto(s)
Neoplasias Óseas , Mieloma Múltiple , Humanos , Imagen por Resonancia Magnética/métodos , Imagen de Cuerpo Entero/métodos , Neoplasias Óseas/patología , Cintigrafía
13.
Sci Rep ; 14(1): 2169, 2024 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-38272956

RESUMEN

The Advanced Trauma Life Support (ATLS) approach is generally accepted as the standard of care for the initial management of severely injured patients. While whole body computed tomography (WBCT) is still considered a contraindication in haemodynamically unstable trauma patients, there is a growing amount of data indicating the absence of harm from cross sectional imaging in this patient group. Our study aimed to compare the early mortality of unstable trauma patients undergoing a WBCT during the initial workup with those who did not. Single-center retrospective observational study based on the local trauma registry including 3525 patients with an ISS > 15 from January 2008 to June 2020. We compared the 24-h mortality of injured patients in circulatory shock undergoing WBCT with a control group undergoing standard workup only. Inclusion criteria were the simultaneous presence of a systolic blood pressure < 100 mmHg, lactate > 2.2 mmol/l and base excess < - 2 mmol/l as surrogate markers for circulatory shock. To control for confounding, a propensity score matched analysis with conditional logistic regression for adjustment of residual confounders and a sensitivity analysis using inverse probability weighting (IPW) with and without adjustment were performed. Of the 3525 patients, 161 (4.6%) fulfilled all inclusion criteria. Of these, 132 (82%) underwent WBCT and 29 (18%) standard work-up only. In crude and matched analyses, no difference in early (24 h) mortality was observed (WBCT, 23 (17.4%) and no-WBCT, 8 (27.6%); p = 0.21). After matching and adjustment for main confounders, the odds ratio for the event of death at 24 h in the WBCT group was 0.36 (95% CI 0.07-1.73); p = 0.20. In the present study, WBCT did not increase the risk of death at 24 h among injured patients in shock. This adds to the growing data indicating that WBCT may be offered to trauma patients in circulatory shock without jeopardizing early survival.


Asunto(s)
Choque , Imagen de Cuerpo Entero , Humanos , Imagen de Cuerpo Entero/métodos , Puntaje de Gravedad del Traumatismo , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Choque/diagnóstico por imagen , Ácido Láctico
14.
Cancer Imaging ; 24(1): 21, 2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38291522

RESUMEN

BACKGROUND: I-131 treatment (RAI) decision relies heavily on serum thyroglobulin (Tg) levels, as higher Tg levels are assumed to be correlated with higher I-131 uptake. Tg elevation, negative iodine scintigraphy (TENIS) definition is becoming more clinically relevant as alternative treatment methods are available. This study examined the correlation between Tg levels with I-131 uptake in remnant thyroid gland to evaluate the reliability of serum Tg levels in predicting I-131 uptake. METHODS: From March 2012 to July 2019, 281 papillary thyroid cancer patients treated with 150 mCi RAI were retrospectively enrolled. Early (2nd day) and Delayed (7th day) post-RAI whole-body scan (WBS) neck counts were correlated with clinical and pathologic findings. Patients with normal neck ultrasound and undetectable level of serum Tg (< 0.2 ng/mL) and thyroglobulin antibody (TgAb) (< 10 IU/mL) were defined as ablation success within 2 years after I-131 ablation. RESULTS: Thyroid gland weight, tumor size and thyroiditis were independent factors of preoperative serum Tg levels. Serum off-Tg levels correlated with Early and Delayed WBS neck counts, and thyroiditis pathology contributed to lower neck counts in both Early and Delayed WBSs. In multivariable analysis, Delayed WBS neck count, serum off-Tg and off-TgAb were significant factors for predicting ablation success. CONCLUSION: I-131 uptake and retention in remnant thyroid gland correlates with serum off-Tg levels, thyroiditis, and ablation success in thyroid cancer patients receiving high-dose I-131 therapy. Semi-quantitative I-131 analysis with Early and Delayed WBSs provides additional information in evaluating ablation success, with the potential application for metastasis treatment response evaluation.


Asunto(s)
Neoplasias de la Tiroides , Tiroiditis , Humanos , Imagen de Cuerpo Entero/métodos , Tiroglobulina , Radioisótopos de Yodo/uso terapéutico , Estudios Retrospectivos , Reproducibilidad de los Resultados , Neoplasias de la Tiroides/diagnóstico por imagen , Neoplasias de la Tiroides/radioterapia , Tiroiditis/tratamiento farmacológico
15.
Eur Radiol ; 34(1): 165-178, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37555959

RESUMEN

OBJECTIVE: The aim of this study was to assess the diffusion-weighted whole-body-MRI (WBMRI) in the initial staging of breast cancer at high risk of metastases in comparison with positron emission tomography (PET)-CT. METHODS: Forty-five women were prospectively enrolled. The inclusion criteria were female gender, age >18, invasive breast cancer, an initial PET-CT, and a performance status of 0-2. The exclusion criteria were contraindication to WB-MRI and breast cancer recurrence. The primary outcome was the concordance of WB-MRI and PET-CT in the diagnosis of distant metastases, whereas secondary outcomes included their concordance for the primary tumor and regional lymph nodes (LN), as well as the agreement of WB-MRI interpretation between two radiologists. RESULTS: The mean age was 51.2 years with a median size of the primary tumor of 30 mm. Concordance between the two modalities was almost perfect for metastases staging, all sites included (k = 0.862), with excellent interobserver agreement. The accuracy of WB-MRI for detecting regional LN, distant LN, lung, liver, or bone metastases ranged from 91 to 96%. In 2 patients, WB-MRI detected bone metastases that were overlooked by PET-CT. WB-MRI showed a substantial agreement with PET-CT for staging the primary tumor, regional LN status, and stage (k = 0.766, k = 0.756, and k = 0.785, respectively) with a high interobserver agreement. CONCLUSION: WB-MRI including DWI could be a reliable and reproducible examination in the initial staging of breast cancer patients at high risk of metastases, especially for bone metastases and therefore could be used as a surrogate to PET-CT. CLINICAL RELEVANCE STATEMENT: Whole-body-MRI including DWI is a promising technique for detecting metastases in the initial staging of breast cancer at high risk of metastases. KEY POINTS: Whole-body-MRI (WB-MRI) was effective for detecting metastases in the initial staging of 45 breast cancer patients at high risk of metastases in comparison with PET-CT. Concordance between WB-MRI and PET-CT was almost perfect for metastases staging, all sites included, with excellent interobserver agreement. The accuracy of WB-MRI for detecting bone metastases was 92%.


Asunto(s)
Neoplasias Óseas , Neoplasias de la Mama , Humanos , Femenino , Persona de Mediana Edad , Masculino , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Neoplasias de la Mama/diagnóstico por imagen , Estudios Prospectivos , Estadificación de Neoplasias , Recurrencia Local de Neoplasia , Imagen por Resonancia Magnética/métodos , Tomografía de Emisión de Positrones/métodos , Neoplasias Óseas/diagnóstico por imagen , Imagen de Cuerpo Entero/métodos , Fluorodesoxiglucosa F18
16.
Eur Radiol ; 34(1): 643-653, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37542653

RESUMEN

OBJECTIVE: To compare tumor therapy response assessments with whole-body diffusion-weighted imaging (WB-DWI) and 18F-fluorodeoxyglucose ([18F]FDG) PET/MRI in pediatric patients with Hodgkin lymphoma and non-Hodgkin lymphoma. MATERIALS AND METHODS: In a retrospective, non-randomized single-center study, we reviewed serial simultaneous WB-DWI and [18F]FDG PET/MRI scans of 45 children and young adults (27 males; mean age, 13 years ± 5 [standard deviation]; age range, 1-21 years) with Hodgkin lymphoma (n = 20) and non-Hodgkin lymphoma (n = 25) between February 2018 and October 2022. We measured minimum tumor apparent diffusion coefficient (ADCmin) and maximum standardized uptake value (SUVmax) of up to six target lesions and assessed therapy response according to Lugano criteria and modified criteria for WB-DWI. We evaluated the agreement between WB-DWI- and [18F]FDG PET/MRI-based response classifications with Gwet's agreement coefficient (AC). RESULTS: After induction chemotherapy, 95% (19 of 20) of patients with Hodgkin lymphoma and 72% (18 of 25) of patients with non-Hodgkin lymphoma showed concordant response in tumor metabolism and proton diffusion. We found a high agreement between treatment response assessments on WB-DWI and [18F]FDG PET/MRI (Gwet's AC = 0.94; 95% confidence interval [CI]: 0.82, 1.00) in patients with Hodgkin lymphoma, and a lower agreement for patients with non-Hodgkin lymphoma (Gwet's AC = 0.66; 95% CI: 0.43, 0.90). After completion of therapy, there was an excellent agreement between WB-DWI and [18F]FDG PET/MRI response assessments (Gwet's AC = 0.97; 95% CI: 0.91, 1). CONCLUSION: Therapy response of Hodgkin lymphoma can be evaluated with either [18F]FDG PET or WB-DWI, whereas patients with non-Hodgkin lymphoma may benefit from a combined approach. CLINICAL RELEVANCE STATEMENT: Hodgkin lymphoma and non-Hodgkin lymphoma exhibit different patterns of tumor response to induction chemotherapy on diffusion-weighted MRI and PET/MRI. KEY POINTS: • Diffusion-weighted imaging has been proposed as an alternative imaging to assess tumor response without ionizing radiation. • After induction therapy, whole-body diffusion-weighted imaging and PET/MRI revealed a higher agreement in patients with Hodgkin lymphoma than in those with non-Hodgkin lymphoma. • At the end of therapy, whole-body diffusion-weighted imaging and PET/MRI revealed an excellent agreement for overall tumor therapy responses for all lymphoma types.


Asunto(s)
Enfermedad de Hodgkin , Linfoma no Hodgkin , Masculino , Adulto Joven , Humanos , Niño , Lactante , Preescolar , Adolescente , Adulto , Fluorodesoxiglucosa F18 , Enfermedad de Hodgkin/diagnóstico por imagen , Enfermedad de Hodgkin/terapia , Enfermedad de Hodgkin/patología , Estudios Retrospectivos , Radiofármacos , Imagen por Resonancia Magnética/métodos , Imagen de Difusión por Resonancia Magnética/métodos , Linfoma no Hodgkin/diagnóstico por imagen , Linfoma no Hodgkin/terapia , Linfoma no Hodgkin/patología , Tomografía de Emisión de Positrones/métodos , Imagen de Cuerpo Entero/métodos
17.
Indian J Cancer ; 60(3): 303-309, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37787189

RESUMEN

Background: Whole-body diffusion-weighted imaging (WB-DWI) is commonly used for the detection of multiple myeloma (MM). Comparative data on the efficiency of WB-DWI compared with F-18 fluoro-2-deoxy-d-glucose positron emission tomography-computed tomography (18F-FDG PET/CT) to detect MM is limited. Methods: This was a retrospective, single-center study of 22 patients with MM enrolled from January 2018 to December 2019. All patients underwent WB-DWI and 18F-FDG PET/CT. Pathological and clinical manifestations, as well as radiologic follow-up, were used for diagnosis. The overall accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of both methods were compared. The apparent diffusion coefficient (ADC) values of MM lesions and false-positive lesions were estimated. Results: A total of 214 MM bone lesions were evaluated. There was no significant difference in the accuracy of WB-DWI and PET/CT (86.92 versus 88.32%). Though WB-DWI had a higher sensitivity (99.26% versus84.56%) and PET-CT had a higher specificity (96.10% versus 64.56%), these differences were not statistically significant. There was a statistically significant difference in PPV (83.33% versus 96.64%) and NPV (98.08% versus 77.89%) of WB-DWI and PET/CT, respectively. The ADC value for MM lesions was significantly lower than that for false-positive lesions (P < 0.001). Receiver operating curve analysis showed that the AUC was 0.846, and when the cut-off value was 0.745 × 10-3 mm2/s, the sensitivity and specificity were 86.3 and 83.4%, respectively, which distinguished MM lesions from non-MM lesions. Conclusion: WB-DWI and PET-CT scans have similar overall accuracy for detecting MM lesions. The higher PPV of PET-CT and NPV of WB-DWI make them complementary imaging modalities. The ADC value for MM lesions is significantly lower than that for false-positive lesions. An ADC cutoff value of 0.745 × 10-3 mm2/s results in sensitivity and specificity of 86.3 and 83.4%, respectively.


Asunto(s)
Mieloma Múltiple , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Fluorodesoxiglucosa F18 , Mieloma Múltiple/diagnóstico por imagen , Estudios Retrospectivos , Tomografía de Emisión de Positrones/métodos , Sensibilidad y Especificidad , Radiofármacos , Imagen de Cuerpo Entero/métodos
18.
Pediatr Radiol ; 53(13): 2683-2691, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37814104

RESUMEN

BACKGROUND: Whole-body magnetic resonance imaging (MRI) has been investigated by multiple authors as a radiation-free alternative to positron emission tomography computed tomography (PET-CT) in children with lymphoma. OBJECTIVE: To evaluate the sensitivity, specificity, and diagnostic odds ratio of whole-body MRI compared to PET-CT for the staging of pediatric lymphoma. METHODS: The databases PubMed, Embase, and Scopus were searched for studies that reported the accuracy of whole-body MRI compared to PET-CT for lymphoma staging in children. Data was collected from included studies to formulate 2 × 2 contingency tables, including the number of true positive, true negative, false positive, and false negative. The pooled sensitivity, specificity, and diagnostic odds ratio (DOR) were calculated. Summary receiver operating characteristic curves were drawn and the area under the curve (AUC) calculated. In addition, the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS 2) tool was used to assess the risk of bias and applicability concerns. RESULTS: A total of seven studies were included in the final analysis. Of these, six studies used unenhanced whole-body MRI. The pooled sensitivity of whole-body MRI-based staging was 95.8%, while the pooled specificity was 21.8%. The DOR for whole-body MRI was 1.19. For extranodal staging, the pooled sensitivity was 88.9%, specificity was 97.4%, and DOR was 25.29. The partial AUC for overall staging was 0.63, whereas that for extranodal staging stood at 0.88. Based on the QUADAS 2 tool, all seven studies were at risk of bias (six at high risk, one at unclear risk). CONCLUSION: Whole-body MRI has high sensitivity for staging of pediatric lymphoma and may be a useful alternative to PET-CT.


Asunto(s)
Linfoma , Tomografía Computarizada por Tomografía de Emisión de Positrones , Niño , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X/métodos , Sensibilidad y Especificidad , Imagen de Cuerpo Entero/métodos , Linfoma/diagnóstico por imagen , Linfoma/patología , Tomografía de Emisión de Positrones , Estadificación de Neoplasias , Fluorodesoxiglucosa F18 , Radiofármacos
19.
Radiol Med ; 128(8): 960-969, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37395842

RESUMEN

INTRODUCTION: Whole body magnetic resonance imaging (WB-MRI) is a promising emerging imaging technology for detecting bone and soft tissue pathology, especially in the onco-hematological field. This study aims to evaluate cancer patients' experience of WB-MRI performed on a 3T scanner compared to other diagnostic total body examinations. MATERIAL AND METHOD: In this prospective committee-approved study, patients completed a questionnaire in person (n = 134) after undergoing a WB-MRI scan to collect data on their physical and psychological reactions during the scan, the global satisfaction level, and preference for other types of MRI or computed tomography (CT), or positron emission tomography (PET/CT). Of all patients who had performed a CT or PET/CT the previous year, 61.9% had already undergone an MRI. The most common symptoms reported were: 38.1% perceived a localized increase in temperature and 34.4% numbness and tingling of the limbs. The scan time averaged 45 min and was well tolerated by most patients (112, 85.5%). Overall, WB-MRI was appreciated by the majority (121/134-90.3%) of patients who said they would probably undergo the procedure again. Patients preferred the WB-MRI in 68.7% of cases (92/134), followed by CT in 15.7% of cases (21/134) and by PET/CT in 7.4% (10/134), with 8.4% (11/134) of patients without any preference. The preference for imaging modalities was age-dependent (p = 0.011), while (p > 0.05) was independent of sex and a primary cancer site. CONCLUSION: These results demonstrate a high degree of WB-MRI acceptance from a patient's point of view.


Asunto(s)
Neoplasias , Radiología , Humanos , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Estudios Prospectivos , Imagen de Cuerpo Entero/métodos , Neoplasias/diagnóstico por imagen , Tomografía de Emisión de Positrones , Atención Dirigida al Paciente , Fluorodesoxiglucosa F18 , Estadificación de Neoplasias
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...