Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29.171
Filtrar
1.
Laeknabladid ; 110(5): 247-253, 2024 May.
Artículo en Islandés | MEDLINE | ID: mdl-38713559

RESUMEN

INTRODUCTION: One of the most serious complications of surgical aortic valve replacement (SAVR) is stroke that can result in increased rates of complications, morbidity and mortality postoperatively. The aim of this study was to investigate incidence, risk factors and short-term outcome in a well defined cohort of SAVR-patients. MATERIALS AND METHOD: A retrospective study on 740 consecutive aortic stenosis patients who underwent SAVR in Iceland 2002-2019. Patients with stroke were compared with non-stroke patients; including preoperative risk factors of cardiovascular disease, echocardiogram-results, rate of early postoperative complications other than stroke and 30 day mortality. RESULTS: Mean age was 71 yrs (34% females) with 57% of the patients receiving stented bioprosthesis, 31% a stentless Freestyle®-valve and 12% a mechanical valve. Mean EuroSCORE-II was 3.6, with a maximum preop-gradient of 70 mmHg and an estimated valvular area of 0.73 cm2. Thirteen (1.8%) patients were diagnosed with stroke where hemiplegia (n=9), loss of consciousness (n=3) and/or aphasia (n=4) were the most common presenting symptoms. In 70% of cases the neurological symptoms resolved or disappeared in the first weeks and months after surgery. Only one patient out of 13 died within 30-days (7.7%). Stroke-patients had significantly lower BMI than non-stroke patients, but other risk factors of cardiovascular diseases, intraoperative factors or the rate of other severe postoperative complications than stroke were similar between groups. Total length of stay was 14 days vs. 10 days median, including 2 vs. 1 days in the ICU, in the stroke and non-stroke-groups, respectively. CONCLUSIONS: The rate of stroke after SAVR was low (1.8%) and in line with other similar studies. Although a severe complication, most patients with perioperative stroke survived 30 days postoperatively and in majority of cases neurological symptoms recovered.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Humanos , Femenino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Masculino , Anciano , Factores de Riesgo , Estudios Retrospectivos , Islandia/epidemiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/mortalidad , Accidente Cerebrovascular/etiología , Incidencia , Factores de Tiempo , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Medición de Riesgo , Anciano de 80 o más Años , Persona de Mediana Edad
2.
Ann Card Anaesth ; 27(1): 68-69, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38722126

RESUMEN

ABSTRACT: The occurrence of pulmonary artery thrombus in association with rheumatic mitral stenosis is a rare complication. Pulmonary artery thrombus formation may worsen pulmonary artery pressures, and this may precipitate acute right heart failure. The possible mechanisms behind pulmonary artery thrombus formation during mitral valve replacement surgery could be acute coagulopathy following surgery, the presence of chronic pulmonary thromboembolism, or chronic atrial fibrillation. We report an unusual case of pulmonary artery thrombus in a patient with rheumatic MS which was diagnosed with transoesophageal echocardiography after MVR.


Asunto(s)
Diagnóstico Tardío , Ecocardiografía Transesofágica , Implantación de Prótesis de Válvulas Cardíacas , Válvula Mitral , Arteria Pulmonar , Trombosis , Humanos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Arteria Pulmonar/diagnóstico por imagen , Ecocardiografía Transesofágica/métodos , Trombosis/diagnóstico por imagen , Trombosis/etiología , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/cirugía , Femenino , Cardiopatía Reumática/complicaciones , Cardiopatía Reumática/cirugía , Embolia Pulmonar/etiología , Embolia Pulmonar/diagnóstico por imagen , Persona de Mediana Edad
4.
J Cardiothorac Surg ; 19(1): 279, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38715032

RESUMEN

OBJECTIVE: Reports on long-term outcomes of surgical aortic valve replacement (AVR) for patients aged < 60 years are scarce in Japan. Hence, we aimed to evaluate these outcomes in patients aged < 60 years. METHODS: Between March 2000 and December 2020, 1477 patients underwent aortic valve replacement. In total, 170 patients aged < 60 years who underwent aortic valve replacement were recruited. Patients aged < 18 years were excluded. Patient data collected from the operative records and follow-up assessments were reviewed. RESULTS: The mean age was 49 ± 9 years, and 64.1% of patients were male. One-hundred-and-fifty-two patients (89.4%) underwent aortic valve replacement with a mechanical valve and 18 (10.6%) with a bioprosthetic valve. The mean follow-up period was 8.1 ± 5.5 years. No operative mortality occurred, and in-hospital mortality occurred in one patient (0.6%). Ten late deaths occurred, with seven cardiac-related deaths. The overall survival rate was 95.4 ± 1.7%, 93.9 ± 2.3%, 90.6 ± 3.9%, and 73.2 ± 11.8% at 5, 10, 15, and 20 years, respectively. Freedom from major bleeding was 96.4 ± 1.6% at 5, 10, and 15 years, and 89.0 ± 7.3% at 20 years. Freedom from thromboembolic events was 98.7 ± 1.3%, 97.3 ± 1.9%, 90.5 ± 4.5%, and 79.0 ± 11.3% at 5, 10, 15, and 20 years, respectively. Freedom from valve-related reoperation was 99.4 ± 0.6% at 5 years, 97.8 ± 1.7% at 10 and 15 years, and 63.9 ± 14.5% at 20 years. CONCLUSIONS: Patients aged < 60 years undergoing aortic valve replacement with a high mechanical valve implantation rate had favorable long-term outcomes.


Asunto(s)
Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Aórtica/cirugía , Adulto , Bioprótesis , Estudios Retrospectivos , Complicaciones Posoperatorias/epidemiología , Japón/epidemiología , Estudios de Seguimiento , Resultado del Tratamiento , Tasa de Supervivencia/tendencias , Factores de Edad , Factores de Tiempo , Mortalidad Hospitalaria
5.
Artículo en Inglés | MEDLINE | ID: mdl-38787287

RESUMEN

Aortic root reconstruction during aortic root replacement for a patient with prosthetic valve endocarditis and aortic root abscess can be a difficult procedure with many possible complications. In this video case report, we describe our novel technique using a single bovine pericardial patch that avoids deep stitches or external sutures to support the friable annulus. Compared with more standard methods, this approach has shorter cross-clamp and cardiopulmonary bypass times and is less demanding technically.


Asunto(s)
Válvula Aórtica , Prótesis Valvulares Cardíacas , Humanos , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Infecciones Relacionadas con Prótesis/cirugía , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/etiología , Masculino , Endocarditis/cirugía , Endocarditis Bacteriana/cirugía , Endocarditis Bacteriana/diagnóstico , Pericardio/trasplante , Procedimientos de Cirugía Plástica/métodos , Persona de Mediana Edad , Animales , Bovinos
6.
Open Heart ; 11(1)2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38769066

RESUMEN

OBJECTIVE: Patients with moderate aortic stenosis (AS) exhibit high morbidity and mortality. Limited evidence exists on the role of aortic valve replacement (AVR) in this patient population. To investigate the benefit of AVR in moderate AS on survival and left ventricular function. METHODS: In a retrospective cohort study, patients with moderate AS between 2008 and 2016 were selected from the Cleveland Clinic echocardiography database and followed until 2018. Patients were classified as receiving AVR or managed medically (clinical surveillance). All-cause and cardiovascular mortality were assessed by survival analyses. Temporal haemodynamic and structural changes were assessed with longitudinal analyses using linear mixed effects models. RESULTS: We included 1421 patients (mean age, 75.3±5.4 years and 39.9% women) followed over a median duration of 6 years. Patients in the AVR group had lower risk of all-cause (adjusted HR (aHR)=0.51, 95% CI: 0.34 to 0.77; p=0.001) and cardiovascular mortality (aHR=0.50, 95% CI: 0.31 to 0.80; p=0.004) compared with those in the clinical surveillance group irrespective of sex, receipt of other open-heart surgeries and underlying malignancy. These findings were seen only in those with preserved left ventricular ejection fraction (LVEF) ≥50%. Further, patients in the AVR group had a significant trend towards an increase in LVEF and a decrease in right ventricular systolic pressure compared with those in the clinical surveillance group. CONCLUSIONS: In patients with moderate AS, AVR was associated with favourable clinical outcomes and left ventricular remodelling.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Función Ventricular Izquierda , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/diagnóstico , Femenino , Masculino , Estudios Retrospectivos , Anciano , Implantación de Prótesis de Válvulas Cardíacas/métodos , Función Ventricular Izquierda/fisiología , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Resultado del Tratamiento , Factores de Tiempo , Índice de Severidad de la Enfermedad , Estudios de Seguimiento , Factores de Riesgo , Ecocardiografía/métodos , Anciano de 80 o más Años , Tasa de Supervivencia/tendencias , Medición de Riesgo/métodos , Volumen Sistólico/fisiología
7.
JACC Cardiovasc Interv ; 17(9): 1079-1090, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38749587

RESUMEN

Tetralogy of Fallot (TOF) is the most common form of cyanotic congenital heart disease. Palliative procedures, either surgical or transcatheter, aim to improve oxygen saturation, affording definitive procedures at a later stage. Transcatheter interventions have been used before and after surgical palliative or definitive repair in children and adults. This review aims to provide an overview of the different catheter-based interventions for TOF across all age groups, with an emphasis on palliative interventions, such as patent arterial duct stenting, right ventricular outflow tract stenting, or balloon pulmonary valvuloplasty in infants and children and transcatheter pulmonary valve replacement in adults with repaired TOF, including the available options for a large, dilated native right ventricular outflow tract.


Asunto(s)
Valvuloplastia con Balón , Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Cuidados Paliativos , Stents , Tetralogía de Fallot , Humanos , Tetralogía de Fallot/cirugía , Tetralogía de Fallot/diagnóstico por imagen , Tetralogía de Fallot/fisiopatología , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Lactante , Resultado del Tratamiento , Factores de Edad , Preescolar , Niño , Adulto , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Adolescente , Recién Nacido , Adulto Joven , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Factores de Riesgo , Femenino , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Válvula Pulmonar/fisiopatología , Masculino , Hemodinámica , Persona de Mediana Edad , Recuperación de la Función
8.
Sci Rep ; 14(1): 11745, 2024 05 23.
Artículo en Inglés | MEDLINE | ID: mdl-38778204

RESUMEN

Preclinical in vivo evaluation is an essential step in the progression of new cardiac devices into patient use, with studies predominantly performed in the domestic sheep model. A growing area of interest in cardiac device development is transcatheter mitral valve replacement (TMVR). Clinically, multimodal imaging, or computed tomography (CT) and echocardiography (echo) are used extensively to preoperatively determine mitral valve morphology prior to an intervention, but there is no description on how these modalities can be implemented to support preclinical studies. The purpose of this study is to apply clinically relevant CT and echo acquisition and assessment techniques to a large group of naive research sheep in order to analyze and report modality-related effects on mitral valve dimensional reference intervals in the sheep model. To this end, fifty-five adult domestic sheep underwent preoperative CT and echo exams and resultant images were analyzed using a landmark-based multiplanar measurement protocol and compiled into a master dataset for statistical analysis. We found moderate agreement between CT and echo-derived measurements of the mitral valve in sheep and propose the first clinically-relevant dimensional indices for the sheep's naive mitral valve which can be used to guide future studies evaluating novel TMVR devices. This study is the first of its kind in proposing a reproducible method for detailed examination of the mitral valve in the sheep model using clinically-relevant multimodal imaging. As in patients, CT and echo can reveal accurate native mitral valve dimensions in the sheep prior to preclinical TMVR studies.


Asunto(s)
Ecocardiografía , Implantación de Prótesis de Válvulas Cardíacas , Válvula Mitral , Imagen Multimodal , Tomografía Computarizada por Rayos X , Animales , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Ovinos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Ecocardiografía/métodos , Tomografía Computarizada por Rayos X/métodos , Imagen Multimodal/métodos , Oveja Doméstica , Cateterismo Cardíaco/métodos
9.
PLoS One ; 19(5): e0301939, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38781278

RESUMEN

BACKGROUND: Transcatheter mitral valve replacement (TMVR) has garnered interest as a viable alternative to the traditional surgical mitral valve replacement (SMVR) for high-risk patients requiring redo operations. This study aims to evaluate the association of TMVR with selected clinical and financial outcomes. METHODS: Adults undergoing isolated redo mitral valve replacement were identified in the 2016-2020 Nationwide Readmissions Database and categorized into TMVR or SMVR cohorts. Various regression models were developed to assess the association between TMVR and in-hospital mortality, as well as additional secondary outcomes. Transseptal and transapical catheter-based approaches were also compared in relation to study endpoints. RESULTS: Of an estimated 7,725 patients, 2,941 (38.1%) underwent TMVR. During the study period, the proportion of TMVR for redo operations increased from 17.8% to 46.7% (nptrend<0.001). Following adjustment, TMVR was associated with similar odds of in-hospital mortality (AOR 0.82, p = 0.48), but lower odds of stroke (AOR 0.44, p = 0.001), prolonged ventilation (AOR 0.43, p<0.001), acute kidney injury (AOR 0.61, p<0.001), and reoperation (AOR 0.29, p = 0.02). TMVR was additionally correlated with shorter postoperative length of stay (pLOS; ß -0.98, p<0.001) and reduced costs (ß -$10,100, p = 0.002). Additional analysis demonstrated that the transseptal approach had lower adjusted mortality (AOR 0.44, p = 0.02), shorter adjusted pLOS (ß -0.43, p<0.001), but higher overall costs (ß $5,200, p = 0.04), compared to transapical. CONCLUSIONS: In this retrospective cohort study, we noted TMVR to yield similar odds of in-hospital mortality as SMVR, but fewer complications and reduced healthcare expenditures. Moreover, transseptal approaches were associated with lower adjusted mortality, shorter pLOS, but higher cost, relative to the transapical. Our findings suggest that TMVR represent a cost-effective and safe treatment modality for patients requiring redo mitral valve procedures. Nevertheless, future studies examining long-term outcomes associated with SMVR and TMVR in redo mitral valve operations, are needed.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Mortalidad Hospitalaria , Válvula Mitral , Humanos , Masculino , Femenino , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/economía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Anciano , Válvula Mitral/cirugía , Persona de Mediana Edad , Reoperación/estadística & datos numéricos , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/economía , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Estudios Retrospectivos , Tiempo de Internación , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/etiología , Anciano de 80 o más Años , Estados Unidos/epidemiología
10.
Curr Probl Cardiol ; 49(7): 102622, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38718933

RESUMEN

Rheumatic heart disease remains a major cause of cardiovascular death worldwide. Limited real-world nationwide data are available to compare the long-term outcomes between mitral valve repair and replacement in rheumatic heart disease. For patients with RHD, MVP is the superior choice of surgical intervention owing to better long-term survival, reduced incidence of early mortality and thromboembolic events. However, it entails higher chances of re-operation at follow-up at four, eight and twelve years. Although feasible, surgeons may opt for MVR in patients with a worse prognosis. Whereas degenerative mitral repair for severe MR has been proven superior to replacement, the optimal operative strategy for mitral RHD remains unclear. In developing countries, mitral RHD commonly develops in young patients, predominantly consists of MR rather than MS, and occurs more frequently than in the United States. In addition, the predominant MR etiology (rather than MS), relatively early intervention in the RHD timeline, and variation in Carpentier MR types among developing world populations further make these rheumatic MVs more amenable to repair than replacement. Patients should be carefully selected for mitral valve repair because of its higher reoperation rate, particularly those with previous percutaneous transvenous mitral commissurotomy. Careful assessment of anterior leaflet mobility/calcification to determine mitral repair or replacement was associated with improved outcomes. This decision-making strategy may alter the threshold for rheumatic mitral replacement in the current valve-in-valve era.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Cardiopatía Reumática , Cardiopatía Reumática/cirugía , Cardiopatía Reumática/complicaciones , Humanos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico , Resultado del Tratamiento , Anuloplastia de la Válvula Mitral/métodos , Anuloplastia de la Válvula Mitral/efectos adversos
11.
Curr Probl Cardiol ; 49(7): 102628, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38729276

RESUMEN

Mechanical prosthetic valve thrombosis (MPVT) is a common complication of valvular implantations. This study compared the efficacy and safety of different treatments for MPVT. A systematic search of electronic databases identified studies evaluating surgical, anticoagulant, and thrombolytic therapies. Although several studies of different types have been conducted to evaluate the efficacy of these treatment strategies the lack of randomized controlled trials has resulted in the inability to make a definitive conclusion about the pros and cons of these treatments. Recent treatments, such as slow and ultraslow infusion of thrombolytics, showed comparable efficacy and lower complication rates than traditional methods. Inadequate anticoagulant use is a major risk factor for MPVT, highlighting the importance of prevention. Treatment selection should be individualized based on patient factors and available expertise. Overall, slow and ultraslow infusion of thrombolytics may be a promising treatment option for MPVT.


Asunto(s)
Anticoagulantes , Fibrinolíticos , Prótesis Valvulares Cardíacas , Terapia Trombolítica , Trombosis , Humanos , Prótesis Valvulares Cardíacas/efectos adversos , Trombosis/etiología , Trombosis/prevención & control , Terapia Trombolítica/métodos , Terapia Trombolítica/efectos adversos , Fibrinolíticos/uso terapéutico , Anticoagulantes/uso terapéutico , Factores de Riesgo , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento
12.
Curr Probl Cardiol ; 49(7): 102636, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38735348

RESUMEN

BACKGROUND AND AIM: The ideal surgical intervention for secondary mitral regurgitation (SMR), a disease of the left ventricle not the mitral valve itself, is still debated. We performed an updated systematic review and study-level meta-analysis investigating mitral valve repair (MVr) versus mitral valve replacement (MVR) for adult patients with SMR, with or without coronary artery disease (CAD). METHODS: PubMed, CENTRAL and EMBASE were searched for studies comparing MVr versus MVR. Randomized trial or observational studies were considered eligible. Primary endpoint was long-term mortality for any cause. Kaplan-Meier survival curves were reconstructed and compared with Cox linear regression. Landmark analysis and time-varying hazard ratio (HR) were analyzed. Sensitivity analyses included meta-regression and separate sub-analysis. A random effects model was used. RESULTS: Twenty-three studies (MVr=3,727 and MVR=2,839) were included. One study was a randomized trial, and 19 studies were adjusted. The mean weighted follow-up was 3.7±2.8 years. MVR was associated with significative greater late mortality (HR=1.26; 95 % CI, 1.14-1.39; P<0.0001) at 10-year follow-up. There was a time-varying trend showing an increased risk of mortality in the first 2 years after MVR (HR=1.38; 95 % CI, 1.21-1.56; P<0.0001), after which this difference dissipated (HR=0.94; 95 % CI, 0.81-1.09; P=0.41). Separate sub-analyses showed comparable long-term mortality in patients with concomitant coronary surgery ≥90 %, left ventricle ejection fraction ≤40 %, and sub-valvular apparatus preservation rate of 100 %. CONCLUSIONS: Compared to repair, MVR is associated with higher probability of mortality in the first 2 years following surgery, after which the two procedures showed comparable late mortality rate.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Mitral/cirugía , Resultado del Tratamiento , Anuloplastia de la Válvula Mitral/métodos , Factores de Tiempo
13.
Sci Rep ; 14(1): 10902, 2024 05 13.
Artículo en Inglés | MEDLINE | ID: mdl-38740898

RESUMEN

Calcification of the aortic valve (CAVDS) is a major cause of aortic stenosis (AS) leading to loss of valve function which requires the substitution by surgical aortic valve replacement (SAVR) or transcatheter aortic valve intervention (TAVI). These procedures are associated with high post-intervention mortality, then the corresponding risk assessment is relevant from a clinical standpoint. This study compares the traditional Cox Proportional Hazard (CPH) against Machine Learning (ML) based methods, such as Deep Learning Survival (DeepSurv) and Random Survival Forest (RSF), to identify variables able to estimate the risk of death one year after the intervention, in patients undergoing either to SAVR or TAVI. We found that with all three approaches the combination of six variables, named albumin, age, BMI, glucose, hypertension, and clonal hemopoiesis of indeterminate potential (CHIP), allows for predicting mortality with a c-index of approximately 80 % . Importantly, we found that the ML models have a better prediction capability, making them as effective for statistical analysis in medicine as most state-of-the-art approaches, with the additional advantage that they may expose non-linear relationships. This study aims to improve the early identification of patients at higher risk of death, who could then benefit from a more appropriate therapeutic intervention.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Calcinosis , Aprendizaje Profundo , Humanos , Válvula Aórtica/cirugía , Válvula Aórtica/patología , Calcinosis/cirugía , Calcinosis/mortalidad , Femenino , Masculino , Anciano , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Anciano de 80 o más Años , Análisis de Supervivencia , Factores de Riesgo , Modelos de Riesgos Proporcionales , Medición de Riesgo/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/métodos , Persona de Mediana Edad
14.
J Am Coll Cardiol ; 83(20): 2002-2014, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38749619

RESUMEN

Orthotopic transcatheter tricuspid valve replacement (TTVR) devices have been shown to be highly effective in reducing tricuspid regurgitation (TR), and interest in this therapy is growing with the recent commercial approval of the first orthotopic TTVR. Recent TTVR studies report preexisting cardiac implantable electronic device (CIED) transvalvular leads in ∼35% of patients, with entrapment during valve implantation. Concerns have been raised regarding the safety of entrapping leads and counterbalanced against the risks of transvenous lead extraction (TLE) when indicated. This Heart Valve Collaboratory consensus document attempts to define the patient population with CIED lead-associated or lead-induced TR, describe the risks of lead entrapment during TTVR, delineate the risks and benefits of TLE in this setting, and develop a management algorithm for patients considered for TTVR. An electrophysiologist experienced in CIED management should be part of the multidisciplinary heart team and involved in shared decision making.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Desfibriladores Implantables/efectos adversos , Marcapaso Artificial/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Índice de Severidad de la Enfermedad
15.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38730543

RESUMEN

OBJECTIVES: The aim of this study was to describe trends and outcomes for patients undergoing surgical aortic valve replacement (SAVR) in the Netherlands. METHODS: The Netherlands Heart Registration database was used to report the number and outcomes of isolated, primary SAVR procedures performed from 2007 to 2018 in adult patients. RESULTS: A total of 17 142 procedures were included, of which 77.9% were performed using a biological prosthesis and 21.0% with a mechanical prosthesis. Median logistic EuroSCORE I decreased from 4.6 [interquartile range (IQR) 2.4-7.7] to 4.0 (IQR 2.6-6.0). The 120-day mortality decreased from 3.3% in 2007 to 0.7% in 2018. The median duration of follow-up was 76 months (IQR 53-111). Ten-year survival, when adjusted for age, EuroSCORE I and body surface area, was 72.4%, and adjusted 10-year freedom from reinvervention was 98.1%. Additional analysis for patients under the age of 60 showed no difference between patients treated with a biological or mechanical prosthesis in adjusted 10-year survival, 89.7% vs 91.9±%, respectively (P = 0.25), but a significant difference in adjusted 10-year freedom from reintervention, 90.0±% vs 95.9%, respectively (P < 0.01). CONCLUSIONS: Between 2007 and 2018, age and risk profile of patients undergoing SAVR decreased, especially for patients treated with a biological prosthesis. The 120-day mortality decreased over time. Patients undergoing SAVR nowadays have a risk of 120-day mortality of <1% and 10-year freedom from valve-related reintervention of >95%.


Asunto(s)
Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Masculino , Países Bajos/epidemiología , Femenino , Anciano , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/tendencias , Implantación de Prótesis de Válvulas Cardíacas/estadística & datos numéricos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/métodos , Persona de Mediana Edad , Resultado del Tratamiento , Prótesis Valvulares Cardíacas/tendencias , Anciano de 80 o más Años , Sistema de Registros , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Factores de Riesgo
16.
Trials ; 25(1): 324, 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38755709

RESUMEN

BACKGROUND: The optimal antithrombotic strategy early after aortic valve replacement surgery with a biological valve remains controversial due to lack of high-quality evidence. Either oral anticoagulants or acetylsalicylic acid should be considered for the first 3 months. Hypo-attenuated leaflet thickening on cardiac computed tomography has been associated with latent bioprosthetic valve thrombosis and may be prevented with anticoagulation. We hypothesize that anticoagulation with apixaban is superior to single antiplatelet therapy with acetylsalicylic acid in reducing hypo-attenuated leaflet thickening of bioprosthetic aortic valve prostheses. METHODS: In this prospective, open-label, randomized trial, patients undergoing isolated aortic valve replacement surgery with rapid deployment bioprosthetic valves will be randomized. The treatment group will receive 5 mg of apixaban twice a day for the first 3 months and 100 mg of acetylsalicylic acid thereafter. The control group will be administered 100 mg of acetylsalicylic acid once a day, indefinitely. After the 3-month treatment period, a contrast-enhanced electrocardiogram-gated cardiac computed tomography will be performed to identify hypo-attenuated leaflet thickening of the bioprosthetic valve. The primary objective of the study is to assess the impact of apixaban on the prevention of hypo-attenuated leaflet thickening at 3 months. The secondary and exploratory endpoints will be clinical outcomes and safety profiles of the two strategies. DISCUSSION: Antithrombotic therapy after aortic valve replacement is used to prevent valve thrombosis and systemic thromboembolism. Latent bioprosthetic valve thrombosis is a precursor of clinically significant prosthetic valve dysfunction or thromboembolic events. The hallmark feature of latent bioprosthetic valve thrombosis is hypo-attenuated leaflet thickening on cardiac computed tomography. Subclinical leaflet thrombosis occurs frequently in bioprosthetic aortic valves, more commonly in transcatheter than in surgical valves. There is no evidence on the effect of direct oral anticoagulants on the incidence of hypo-attenuated leaflet thickening after surgical aortic valve replacement with rapid deployment bioprostheses. TRIAL REGISTRATION: ClinicalTrials.gov NCT06184113. Registered on December 28, 2023.


Asunto(s)
Válvula Aórtica , Aspirina , Bioprótesis , Inhibidores del Factor Xa , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Pirazoles , Piridonas , Ensayos Clínicos Controlados Aleatorios como Asunto , Trombosis , Humanos , Aspirina/administración & dosificación , Aspirina/uso terapéutico , Aspirina/efectos adversos , Piridonas/uso terapéutico , Piridonas/administración & dosificación , Piridonas/efectos adversos , Estudios Prospectivos , Prótesis Valvulares Cardíacas/efectos adversos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Trombosis/prevención & control , Trombosis/etiología , Pirazoles/uso terapéutico , Pirazoles/administración & dosificación , Pirazoles/efectos adversos , Inhibidores del Factor Xa/administración & dosificación , Inhibidores del Factor Xa/efectos adversos , Inhibidores del Factor Xa/uso terapéutico , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Inhibidores de Agregación Plaquetaria/administración & dosificación , Inhibidores de Agregación Plaquetaria/uso terapéutico , Inhibidores de Agregación Plaquetaria/efectos adversos , Femenino , Masculino , Persona de Mediana Edad , Factores de Tiempo , Anciano , Adulto , Fibrinolíticos/administración & dosificación , Fibrinolíticos/efectos adversos
17.
Clin Cardiol ; 47(5): e24272, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38742736

RESUMEN

Paravalvular leak (PVL) is an uncommon complication of prosthetic valve implantation, which can lead to infective endocarditis, heart failure, and hemolytic anemia. Surgical reintervention of PVLs is associated with high mortality rates. Transcatheter PVL closure (TPVLc) has emerged as an alternative to surgical reoperation. This method provides a high success rate with a low rate of complications. This article reviews the pathogenesis, clinical manifestation, diagnosis, and management of PVL and complications following TPVLc. Besides, we presented a case of a patient with severe PVL following mitral valve replacement, who experienced complete heart block (CHB) during TPVLc. The first TPVLc procedure failed in our patient due to possible AV-node insult during catheterization. After 1 week of persistent CHB, a permanent pacemaker was implanted. The defect was successfully passed using the previous attempt. Considering the advantages of TPVLc, procedure failure should be regarded as a concern. TPVLc should be performed by experienced medical teams in carefully selected patients.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Mitral , Falla de Prótesis , Humanos , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Ecocardiografía Transesofágica , Masculino , Resultado del Tratamiento , Femenino , Anciano , Reoperación
18.
BMC Cardiovasc Disord ; 24(1): 250, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38745119

RESUMEN

OBJECTIVES: Prolonged mechanical ventilation (PMV) is a common complication following cardiac surgery linked to unfavorable patient prognosis and increased mortality. This study aimed to search for the factors associated with the occurrence of PMV after valve surgery and to develop a risk prediction model. METHODS: The patient cohort was divided into two groups based on the presence or absence of PMV post-surgery. Comprehensive preoperative and intraoperative clinical data were collected. Univariate and multivariate logistic regression analyses were employed to identify risk factors contributing to the incidence of PMV. Based on the logistic regression results, a clinical nomogram was developed. RESULTS: The study included 550 patients who underwent valve surgery, among whom 62 (11.27%) developed PMV. Multivariate logistic regression analysis revealed that age (odds ratio [OR] = 1.082, 95% confidence interval [CI] = 1.042-1.125; P < 0.000), current smokers (OR = 1.953, 95% CI = 1.007-3.787; P = 0.047), left atrial internal diameter index (OR = 1.04, 95% CI = 1.002-1.081; P = 0.041), red blood cell count (OR = 0.49, 95% CI = 0.275-0.876; P = 0.016), and aortic clamping time (OR = 1.031, 95% CI = 1.005-1.057; P < 0.017) independently influenced the occurrence of PMV. A nomogram was constructed based on these factors. In addition, a receiver operating characteristic (ROC) curve was plotted, with an area under the curve (AUC) of 0.782 and an accuracy of 0.884. CONCLUSION: Age, current smokers, left atrial diameter index, red blood cell count, and aortic clamping time are independent risk factors for PMV in patients undergoing valve surgery. Furthermore, the nomogram based on these factors demonstrates the potential for predicting the risk of PMV in patients following valve surgery.


Asunto(s)
Nomogramas , Valor Predictivo de las Pruebas , Respiración Artificial , Humanos , Factores de Riesgo , Masculino , Femenino , Persona de Mediana Edad , Respiración Artificial/efectos adversos , Factores de Tiempo , Medición de Riesgo , Anciano , Estudios Retrospectivos , Resultado del Tratamiento , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Técnicas de Apoyo para la Decisión , Adulto , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Factores de Edad
19.
Braz J Cardiovasc Surg ; 39(4): e20230154, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38748974

RESUMEN

INTRODUCTION: It is not yet clear whether cardiac surgery by mini-incision (minimally invasive cardiac surgery [MICS]) is overall less painful than the conventional approach by full sternotomy (FS). A meta-analysis is necessary to investigate polled results on this topic. METHODS: PubMed®/MEDLINE, Cochrane CENTRAL, Latin American and Caribbean Health Sciences Literature (or LILACS), and Scientific Electronic Library Online (or SciELO) were searched for all clinical trials, reported until 2022, comparing FS with MICS in coronary artery bypass grafting (CABG), mitral valve surgery (MVS), and aortic valve replacement (AVR), and postoperative pain outcome was analyzed. Main summary measures were the method of standardized mean differences (SMD) with a 95% confidence interval (CI) and P-values (considered statistically significant when < 0.05). RESULTS: In AVR, the general estimate of postoperative pain effect favored MICS (SMD 0.87 [95% CI 0.04 to 1.71], P=0.04). However, in the sensitivity analysis, there was no difference between the groups (SMD 0.70 [95% CI -0.69 to 2.09], P=0.32). For MVS, it was not possible to perform a meta-analysis with the included studies, because they had different methodologies. In CABG, the general estimate of the effect of postoperative pain did not favor any of the approaches (SMD -0.40 [95% CI -1.07 to 0.26], P=0.23), which was confirmed by sensitivity analysis (SMD -0.02 [95% CI -0.71 to 0.67], P=0.95). CONCLUSION: MICS was not globally less painful than the FS approach. It seems that postoperative pain is more related to the degree of tissue retraction than to the size of the incision.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Puente de Arteria Coronaria , Procedimientos Quirúrgicos Mínimamente Invasivos , Dolor Postoperatorio , Esternotomía , Humanos , Esternotomía/efectos adversos , Esternotomía/métodos , Dolor Postoperatorio/etiología , Procedimientos Quirúrgicos Cardíacos/métodos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
20.
Braz J Cardiovasc Surg ; 39(4): e20230237, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38748975

RESUMEN

Transcatheter mitral valve-in-valve is an alternative to high-risk reoperation on a failing bioprosthesis. It entails specific challenges such as left ventricular outflow tract obstruction. We propose a patient-specific augmented imaging based on preoperative planning to assist the procedure. Valve-in-valve simulation was performed to represent the optimal level of implantation and the neo-left ventricular outflow tract. These data were combined with intraoperative images through a real-time 3D/2D registration tool. All data were collected retrospectively on one case (pre and per-procedure imaging). We present for the first time an intraoperative guidance tool in transcatheter mitral valve-in-valve procedure.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Mitral , Cirugía Asistida por Computador , Humanos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Cirugía Asistida por Computador/métodos , Cateterismo Cardíaco/métodos , Bioprótesis , Estudios Retrospectivos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Femenino , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...