Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.994
Filtrar
1.
Catheter Cardiovasc Interv ; 103(6): 1074-1077, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38577923

RESUMEN

Transcatheter aortic valve implantation (TAVI) has traditionally been indicated for the treatment of aortic stenosis. However, in this case report, we describe a successful TAVI procedure in a 46-year-old male patient who had previously undergone David aortic valve-sparing aortic root replacement for type 1 aortic dissection. The patient presented with aortic valve insufficiency 4 years after the initial surgery and was subsequently treated with a 34 mm Medtronic CoreValve Evolut R prosthesis via TAVI. This case highlights the feasibility of TAVI as a viable treatment option for postoperative aortic valve insufficiency in patients with prior ascending aortic or aortic arch surgery.


Asunto(s)
Disección Aórtica , Insuficiencia de la Válvula Aórtica , Válvula Aórtica , Implantación de Prótesis Vascular , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Disección Aórtica/cirugía , Disección Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/fisiopatología , Persona de Mediana Edad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Diseño de Prótesis , Prótesis Vascular , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta/cirugía , Aneurisma de la Aorta/diagnóstico por imagen , Aortografía
2.
Tex Heart Inst J ; 51(1)2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38686682

RESUMEN

Quadricuspid aortic valve is a rare congenital cardiac anomaly with an incidence of 0.008% to 0.043%. Its clinical course varies depending on cusp anatomy, function, and associated cardiac malformations. It frequently progresses to aortic valve regurgitation that may require surgical valve replacement. Detection has shifted from incidental discovery during autopsies or cardiac surgeries in the early 20th century to various cardiac imaging methods in recent decades. In addition to contributing to the literature, this report supports the use of transesophageal echocardiography more liberally to detect aortic valve abnormalities. The case presents a 48-year-old female patient with an incidentally discovered quadricuspid aortic valve.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Aórtica , Ecocardiografía Transesofágica , Cardiopatías Congénitas , Hallazgos Incidentales , Humanos , Femenino , Válvula Aórtica/anomalías , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Persona de Mediana Edad , Ecocardiografía Transesofágica/métodos , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/etiología , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/cirugía , Cardiopatías Congénitas/diagnóstico por imagen , Valor Predictivo de las Pruebas , Implantación de Prótesis de Válvulas Cardíacas , Ecocardiografía Doppler en Color
3.
Catheter Cardiovasc Interv ; 103(6): 1015-1022, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38577931

RESUMEN

BACKGROUND: Previous studies have documented a high rate of implantation success with the ACURATE neo2 valve, as well as a reduction in paravalvular leak (PVL) compared to its predecessor, the ACURATE neo. However, there are no studies that have reviewed and compared the long-term clinical and hemodynamic outcomes of these patients. AIMS: This study aimed to evaluate the results of the ACURATE neo transcatheter aortic valve in a real-world context, and to compare the results of the outcomes of both generations of this device (ACURATE neo and ACURATE neo2), with a specific focus on procedural success, safety, and long-term effectiveness. METHODS: A prospective study including all consecutive patients treated with the ACURATE neo device in seven hospitals was conducted (Clinical Trials Identification Number: NCT03846557). The primary endpoint consisted of a composite of adverse events, including mortality, aortic insufficiency, and other procedural complications. As the second-generation device (ACURATE neo2) replaced the ACURATE neo during the study period, hemodynamic and clinical results before admission, at 30 days, and at 1 year of follow-up were compared between the two generations. RESULTS: A total of 296 patients underwent transcatheter aortic valve implantation with the ACURATE device, with 178 patients receiving the ACURATE neo and 118 patients receiving the ACURATE neo2. In the overall population, the absence of device success occurred in 14.5%. The primary reason for the absence of device success was the presence of para-valvular regurgitation ≥ 2. There were no instances of coronary occlusions, valve embolization, annulus rupture, or procedural deaths. ACURATE neo2 was associated with a significantly higher device success rate (91.7% vs. 82%, p = 0.04), primarily due to a significantly lower rate of para-valvular regurgitation, which remained significant at 1 year. CONCLUSION: The use of ACURATE neo and neo2 transcatheter aortic valves is associated with satisfactory clinical results and an extremely low rate of complications. The ACURATE neo2 enables a significantly higher device success rate, primarily attributed to a significant reduction in the rate of PVL.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Hemodinámica , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Complicaciones Posoperatorias , Estudios Prospectivos , Recuperación de la Función , Factores de Riesgo , España , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
4.
EuroIntervention ; 20(6): e363-e375, 2024 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-38506737

RESUMEN

BACKGROUND: There is a lack of comparative data on transcatheter aortic valve implantation (TAVI) in degenerated surgical prostheses (valve-in-valve [ViV]). AIMS: We sought to compare outcomes of using two self-expanding transcatheter heart valve (THV) systems for ViV. METHODS: In this retrospective multicentre registry, we included consecutive patients undergoing transfemoral ViV using either the ACURATE neo/neo2 (ACURATE group) or the Evolut R/PRO/PRO+ (EVOLUT group). The primary outcome measure was technical success according to Valve Academic Research Consortium (VARC)-3. Secondary outcomes were 30-day all-cause mortality, device success (VARC-3), coronary obstruction (CO) requiring intervention, rates of severe prosthesis-patient mismatch (PPM), and aortic regurgitation (AR) ≥moderate. Comparisons were made after 1:1 propensity score matching. RESULTS: The study cohort comprised 835 patients from 20 centres (ACURATE n=251; EVOLUT n=584). In the matched cohort (n=468), technical success (ACURATE 92.7% vs EVOLUT 88.9%; p=0.20) and device success (69.7% vs 73.9%; p=0.36) as well as 30-day mortality (2.8% vs 1.6%; p=0.392) were similar between the two groups. The mean gradients and rates of severe PPM, AR ≥moderate, or CO did not differ between the groups. Technical and device success were higher for the ACURATE platform among patients with a true inner diameter (ID) >19 mm, whereas a true ID ≤19 mm was associated with higher device success - but not technical success - among Evolut recipients. CONCLUSIONS: ViV TAVI using either ACURATE or Evolut THVs showed similar procedural outcomes. However, a true ID >19 mm was associated with higher device success among ACURATE recipients, whereas in patients with a true ID ≤19 mm, device success was higher when using Evolut.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Bioprótesis , Oclusión Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Catéteres , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Válvulas Cardíacas , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
5.
Circ Cardiovasc Interv ; 17(5): e013898, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38533653

RESUMEN

BACKGROUND: Acute aortic regurgitation is life-threatening with few nonsurgical options for immediate stabilization. We propose Trans-Aortic Balloon to Ease Regurgitation Applying Counter-Pulsation (TABERNACL), a simple, on-table temporary valve using commercially available equipment to temporize acute severe aortic regurgitation. METHODS: We hypothesize that an appropriately sized commercial balloon dilatation catheter-straddling the aortic annulus and connected to a counterpulsation console-can serve as a temporizing valve to restore hemodynamic stability in acute aortic regurgitation. We performed benchtop testing of valvuloplasty, angioplasty, and sizing balloons as counterpulsation balloons. TABERNACL was assessed in vivo in a porcine model of acute aortic regurgitation (n=8). We also tested a static undersized, continuously inflated transvalvular balloon as a spacer intended physically to obstruct the regurgitant orifice. RESULTS: Benchtop testing identified that Tyshak II and PTS sizing (NuMed Braun) balloon catheters performed adequately as temporary valves (ie, complete inflation and deflation with each cycle) and resisted fatigue, in contrast to others. When TABERNACL was used in the acute severe regurgitation animals, there was immediate hemodynamic improvement, with a significant 35% increase in diastolic aortic pressure by 16 mm Hg ([95% CI, 7-25] P=0.0056), 34% reduction in left ventricular end-diastolic pressure by -7 mm Hg ([95% CI, -10 to -5] P=0.0006), improvement in the aortic diastolic index by 0.28 ([95% CI, 0.18-0.39] P=0.0009), and reversal of electrocardiographic myocardial ischemia. As an alternative, static balloon inflation across the aortic valve stabilized regurgitation hemodynamics at the expense of a new aortic gradient and caused excessive ectopy from balloon movement in the left ventricular outflow tract. CONCLUSIONS: TABERNACL improves hemodynamics and reduces coronary ischemia by electrocardiography in animals with acute severe aortic regurgitation. TABERNACL valves obstruct the diastolic regurgitant orifice without systolic obstruction. This may prove a lifesaving bridge to definitive valve replacement therapy.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Valvuloplastia con Balón , Modelos Animales de Enfermedad , Hemodinámica , Animales , Hemodinámica/efectos de los fármacos , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Sus scrofa , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Diseño de Equipo , Recuperación de la Función , Enfermedad Aguda , Catéteres Cardíacos , Factores de Tiempo , Índice de Severidad de la Enfermedad , Función Ventricular Izquierda/efectos de los fármacos
6.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38489836

RESUMEN

OBJECTIVES: After staged reconstruction for hypoplastic left heart syndrome, the neoaortic root tends to dilate, and the incidence of significant neoaortic valve insufficiency increases with time. This study aimed to evaluate the mid-term outcomes of the neoaortic root geometries and valve function after chimney reconstruction in the Norwood procedure. METHODS: Between 2013 and 2021, 20 consecutive patients who underwent chimney reconstruction during the Norwood procedure for hypoplastic left heart syndrome and its variants in our institution were enrolled. The actual diameters of the following points were measured, and Z-scores were calculated based on the normal aortic root geometries using the long axis view of echocardiography at the pre-Norwood stage and the lateral view of angiography at pre-Glenn, pre-Fontan, post-Fontan and follow-up (age 5-6 years) stages: neoaortic valve annulus; sinus of Valsalva; sinotubular junction; and ascending aorta just proximal to the anastomosis to the aortic arch. The degree of neoaortic valve regurgitation was evaluated by echocardiography at each stage. RESULTS: The median follow-up period was 3.9 years. Neoaortic roots after chimney reconstruction were spared from progressive dilation over time. With growth, the conical configuration of the neoaortic roots was preserved without geometrical distortion. The Z-scores of the annulus, sinus of Valsalva, sinotubular junction and ascending aorta ranged roughly from 4 to 6, 4 to 6, 2 to 4 and 0 to 2, respectively. All neoaortic valves at each stage had mild or no regurgitation. CONCLUSIONS: Chimney reconstruction prevented neoaortic root dilation and avoided significant neoaortic valve regurgitation in the mid-term. These neoaortic dimensions with smooth flow profiles in the neoaorta after chimney reconstruction may have contributed to the current results. Further studies are needed to clarify the long-term outcomes.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Síndrome del Corazón Izquierdo Hipoplásico , Procedimientos de Norwood , Humanos , Preescolar , Niño , Síndrome del Corazón Izquierdo Hipoplásico/cirugía , Resultado del Tratamiento , Procedimientos de Norwood/efectos adversos , Aorta/cirugía , Ecocardiografía , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Estudios de Seguimiento , Estudios Retrospectivos
7.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38544298

RESUMEN

Pure aortic regurgitation and dilation of aortic annulus are the most significant risk factors for the failure of pulmonary autograft after the Ross procedure. Aortic annuloplasty has a positive effect on the durability of the autograft. Previously, we described a technique for external annuloplasty with dedicated CORONEO ring. In the present manuscript, we suggest the sizing of annuloplasty based on the diameter of pulmonary autograft annulus.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Válvula Pulmonar , Humanos , Autoinjertos , Trasplante Autólogo/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Reoperación/efectos adversos , Válvula Pulmonar/trasplante , Resultado del Tratamiento , Estudios de Seguimiento
8.
Lancet ; 403(10435): 1451-1459, 2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38552656

RESUMEN

BACKGROUND: Surgery remains the only recommended intervention for patients with native aortic regurgitation. A transcatheter therapy to treat patients at high risk for mortality and complications with surgical aortic valve replacement represents an unmet need. Commercial transcatheter heart valves in pure aortic regurgitation are hampered by unacceptable rates of embolisation and paravalvular regurgitation. The Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) provides a treatment option for these patients. We report outcomes with transfemoral transcatheter aortic valve implantation (TAVI) in patients with pure aortic regurgitation using this dedicated transcatheter heart valve. METHODS: The ALIGN-AR trial is a prospective, multicentre, single-arm study. We recruited symptomatic patients (aged ≥18 years) with moderate-to-severe or severe aortic regurgitation at high risk for mortality and complications after surgical aortic valve replacement at 20 US sites for treatment with the Trilogy transcatheter heart valve. The 30-day composite primary safety endpoint was compared for non-inferiority with a prespecified performance goal of 40·5%. The primary efficacy endpoint was 1-year all-cause mortality compared for non-inferiority with a performance goal of 25%. This trial is registered with ClinicalTrials.gov, NCT04415047, and is ongoing. FINDINGS: Between June 8, 2018, and Aug 29, 2022, we screened 346 patients. We excluded 166 (48%) patients and enrolled 180 (52%) patients with symptomatic aortic regurgitation deemed high risk by the heart team and independent screening committee assessments. The mean age of the study population was 75·5 years (SD 10·8), and 85 (47%) were female, 95 (53%) were male, and 131 (73%) were White. Technical success was achieved in 171 (95%) patients. At 30 days, four (2%) deaths, two (1%) disabling strokes, and two (1%) non-disabling strokes occurred. Using standard Valve Academic Research Consortium-2 definitions, the primary safety endpoint was achieved, with events occurring in 48 (27% [97·5% CI 19·2-34·0]) patients (pnon-inferiority<0·0001), with new pacemaker implantation in 36 (24%) patients. The primary efficacy endpoint was achieved, with mortality in 14 (7·8% [3·3-12·3]) patients at 1 year (pnon-inferiority<0·0001). INTERPRETATION: This study shows the safety and effectiveness of treating native aortic regurgitation using a dedicated transcatheter heart valve to treat patients with symptomatic moderate-to-severe or severe aortic regurgitation who are at high risk for mortality or complications after surgical aortic valve replacement. The observed short-term clinical and haemodynamic outcomes are promising as are signs of left ventricular remodelling, but long-term follow-up is necessary. FUNDING: JenaValve Technology.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
9.
Kyobu Geka ; 77(3): 206-209, 2024 Mar.
Artículo en Japonés | MEDLINE | ID: mdl-38465492

RESUMEN

We report a case of bioprosthetic valve dysfunction and acute aortic valve regurgitation. The case was a 75-year-old female who had sudden onset chest pain. ST-segment depression in several leads on electrocardiogram( ECG) suggested acute coronary syndrome. Coronary angiography showed no significant stenosis in coronary arteries. Transesophageal echocardiography revealed severe aortic regurgitation, suggesting that angina was caused by myocardial ischemia associated with acute aortic regurgitation. She was diagnosed as having bioprosthetic valve dysfunction, and underwent redo aortic valve replacement. One leaflet of the bioprosthetic valve was torn along the stent post and caused bioprosthetic valve dysfunction. Failed bioprosthetic valve was removed and replaced by a mechanical valve.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Femenino , Humanos , Anciano , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Tórax , Prótesis Valvulares Cardíacas/efectos adversos , Dolor en el Pecho/etiología , Bioprótesis/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
11.
Circ J ; 88(5): 663-671, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38325819

RESUMEN

BACKGROUND: Complications arising from transcatheter closure of perimembranous ventricular septal defects (pmVSD) in children, such as residual shunts and aortic regurgitation (AR), have been observed. However, the associated risk factors remain unclear. This study identified risk factors linked with residual shunts and AR following transcatheter closure of pmVSD in children aged 2-12 years.Methods and Results: The medical records of 63 children with pmVSD and a pulmonary-to-systemic blood flow ratio <2.0 who underwent transcatheter closure between 2011 and 2018 were analyzed with a minimum 3-year follow-up. The success rate of transcatheter closure was 98.4%, with no emergency surgery, permanent high-degree atrioventricular block, or mortality. Defects ≥4.5 mm had significantly higher odds of persistent residual shunt (odds ratio [OR] 6.85; P=0.03). The use of an oversize device (≥1.5 mm) showed a trend towards reducing residual shunts (OR 0.23; P=0.06). Age <4 years (OR 27.38; 95% confidence interval [CI] 2.33-321.68) and perimembranous outlet-type VSD (OR 11.94, 95% CI 1.10-129.81) were independent risk factors for AR progression after closure. CONCLUSIONS: Careful attention is crucial for pmVSDs ≥4.5 mm to prevent persistent residual shunts in transcatheter closure. Assessing AR risk, particularly in children aged <4 years, is essential while considering the benefits of pmVSD closure.


Asunto(s)
Cateterismo Cardíaco , Defectos del Tabique Interventricular , Humanos , Defectos del Tabique Interventricular/cirugía , Preescolar , Niño , Factores de Riesgo , Masculino , Femenino , Cateterismo Cardíaco/efectos adversos , Estudios Retrospectivos , Dispositivo Oclusor Septal/efectos adversos , Resultado del Tratamiento , Insuficiencia de la Válvula Aórtica/etiología , Factores de Edad , Factores de Tiempo , Estudios de Seguimiento , Complicaciones Posoperatorias/etiología
12.
BMJ Case Rep ; 17(2)2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38395470

RESUMEN

The Trifecta tissue valve (Abbott, Illinois, USA) is an externally mounted bovine pericardial aortic valve (AV) prosthesis with adequate haemodynamic performance and better early results than another option. However, concerns have been raised about its durability. Recently, reports have emerged about an increased incidence of early structural valve failure after Trifecta implantation, where leaflet tear(s) with dehiscence along the stent post was the primary mode of early failure. In this article, we present the case of a patient in her 70s, 7 years after AV replacement with a Trifecta valve, who developed progressive dyspnoea. Physical examination revealed signs of chronic severe aortic regurgitation (AR). The initial transthoracic echocardiogram showed severe transvalvular AR, but the aetiology could not be determined. Cardiac computed tomography (CT) revealed a flail non-coronary cusp of the Trifecta bioprosthetic valve without vegetation. After discussion, we concluded that our patient was suitable for valve-in-valve transcatheter aortic valve replacement (ViV TAVR).


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Femenino , Humanos , Animales , Bovinos , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Falla de Prótesis , Bioprótesis/efectos adversos , Diseño de Prótesis , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía
14.
J Am Heart Assoc ; 13(4): e033289, 2024 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-38362873

RESUMEN

BACKGROUND: The management of mixed aortic valve disease (MAVD), defined as the concomitant presence of aortic stenosis (AS) and aortic regurgitation, remains a clinical challenging. The present study assessed the impact of transcatheter aortic valve replacement (TAVR) on cardiac geometry and prognosis in patients with MAVD. METHODS AND RESULTS: A retrospective multicenter TAVR registry was conducted, including patients who underwent TAVR for severe symptomatic AS between January 2015 and March 2019. Patients were subdivided into 2 groups according to concomitant presence of moderate or more severe aortic regurgitation as the MAVD group, and with mild or less severe aortic regurgitation as the isolated AS group. The primary outcome was a composite of cardiovascular death and rehospitalization due to cardiovascular causes. A total of 1742 patients (isolated AS, 1522 patients; MAVD, 220 patients) were included (84.0±5.2 years). Although MAVD exhibited significantly larger left ventricular volumes and higher left ventricular mass index at the TAVR procedure than isolated AS (respectively, P<0.001), MAVD showed a greater improvement of left ventricular volumes and left ventricular mass index after TAVR (respectively, P≤0.001). During a median follow-up of 747 days, 301 patients achieved the primary event. The prognosis post-TAVR was comparable between the 2 groups (log-rank P=0.65). Even after adjustment using propensity score matching to reduce the potential bias between the 2 groups, similar results were obtained for the entire cohort. CONCLUSIONS: Despite more advanced cardiac remodeling in MAVD at the time of TAVR compared with isolated AS, a greater improvement of cardiac reverse remodeling was found in MAVD, and the prognosis following TAVR was comparable between the 2 groups.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Resultado del Tratamiento , Factores de Riesgo , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Pronóstico , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Función Ventricular Izquierda
15.
Glob Heart ; 19(1): 16, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38344744

RESUMEN

Background: Acute rheumatic fever (ARF) with carditis can lead to the development of rheumatic heart disease in children and young adults. Objective: This study aimed to investigate the manifestations of rheumatic carditis, clinically significant regression of valvular regurgitation as assessed by echocardiography, and the independent predictors of mitral regurgitation (MR) improvement after rheumatic carditis in Thai children. Method: Children diagnosed with rheumatic carditis during 2005-2020 at Siriraj Hospital (Bangkok, Thailand) were retrospectively enrolled. Trivial, and mild regurgitation were grouped as non-clinically significant (NCS) regurgitation. Valvular regression was defined moderate-severe regurgitation improving to NCS regurgitation. Results: Eighty-one patients (mean age: 10 years, range: 8-12 years) were included. At presentation, 59 (72.8%) patients had combined mitral regurgitation (MR) and aortic regurgitation (AR), 20 (24.6%) patients had MR alone, and 2 (2.4%) patients had AR alone. Concerning severity, 28 (34.6%) and 30 (37%) patients presented with severe and moderate MR, respectively. Severe and moderate AR was found in 9 (11.1%) and 16 (19.8%) patients, respectively. At the one-year follow-up, 43.4% of moderate-severe MR, and 41.7% of moderate-severe AR improved to NCS regurgitation. Multivariate analysis revealed high erythrocyte sedimentation rate (ESR) (p = 0.01) and severe carditis (p = 0.05) at presentation to be independent predictors of MR improvement. Conclusion: Thai children with rheumatic carditis had a high incidence of valvular regurgitation; however, the valvular damage was improved in most patients. High ESR and severe carditis independently predict MR improvement.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Enfermedades de las Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Miocarditis , Fiebre Reumática , Cardiopatía Reumática , Niño , Adulto Joven , Humanos , Cardiopatía Reumática/complicaciones , Cardiopatía Reumática/epidemiología , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/complicaciones , Tailandia/epidemiología , Miocarditis/epidemiología , Estudios Retrospectivos , Insuficiencia de la Válvula Aórtica/epidemiología , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/etiología
18.
J Cardiothorac Surg ; 19(1): 3, 2024 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-38167451

RESUMEN

BACKGROUND: This study examined the characteristics and outcomes of surgical aortic valve replacement (SAVR) both isolated and in combination with other cardiac surgery in Malaysia from 2015 to 2021. METHODS: This was a retrospective study of 1346 patients analyzed on the basis of medical records, echocardiograms and surgical reports. The overall sample was both considered as a whole and divided into aortic stenosis (AS)/aortic regurgitation (AR)-predominant and similar-severity subgroups. RESULTS: The most common diagnosis was severe AS (34.6%), with the 3 most common etiologies being bicuspid valve degeneration (45.3%), trileaflet valve degeneration (36.3%) and rheumatic valve disease (12.2%). The second most common diagnosis was severe AR (25.5%), with the most common etiologies being root dilatation (21.0%), infective endocarditis (IE) (16.6%) and fused prolapse (12.2%). Rheumatic valve disease was the most common mixed disease. A total of 54.5% had AS-predominant pathology (3 most common etiologies: bicuspid valve degeneration valve, degenerative trileaflet valve and rheumatic valve disease), 36.9% had AR-predominant pathology (top etiologies: root dilatation, rheumatic valve disease and IE), and 8.6% had similar severity of AS and AR. Overall, 62.9% of patients had trileaflet valve morphology, 33.3% bicuspid, 0.6% unicuspid and 0.3% quadricuspid. For AS, the majority were high-gradient severe AS (49.9%), followed by normal-flow low-gradient (LG) severe AS (10.0%), paradoxical low-flow (LF)-LG severe AS (6.4%) and classical LF-LG severe AS (6.1%). The overall in-hospital and total 1-year mortality rates were 6.4% and 14.8%, respectively. Pure severe AS had the highest mortality. For AS-predominant pathology, the etiology with the highest mortality was trileaflet valve degeneration; for AR-predominant pathology, it was dissection. The overall survival probability at 5 years was 79.5% in all patients, 75.7% in the AS-predominant subgroup, 83.3% in the AR-predominant subgroup, and 87.3% in the similar-severity subgroup. CONCLUSIONS: The 3 most common causes of AS- predominant patients undergoing SAVR is bicuspid valve degeneration, degenerative trileaflet valve and rheumatic and for AR-predominant is root dilatation, rheumatic and IE. Rheumatic valve disease is an important etiology in our SAVR patients especially in mixed aortic valve disease. Study registration IJNREC/562/2022.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Endocarditis Bacteriana , Endocarditis , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Cardiopatía Reumática , Humanos , Válvula Aórtica/cirugía , Válvula Aórtica/patología , Estudios Retrospectivos , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/etiología , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Endocarditis Bacteriana/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Hemodinámica , Cardiopatía Reumática/complicaciones , Cardiopatía Reumática/cirugía , Endocarditis/cirugía , Endocarditis/complicaciones
19.
BMC Cardiovasc Disord ; 24(1): 77, 2024 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-38281925

RESUMEN

BACKGROUND: New-generation self-expanding valves can improve the success rate of transcatheter aortic valve replacement (TAVR) for severe pure native aortic regurgitation (PNAR). However, predictors of new-onset conduction block post-TAVR using new-generation self-expanding valves in patients with PNAR remain to be established. Therefore, this study aimed to identify predictors of new-onset conduction block post-TAVR using new-generation self-expanding valves (VitaFlow Liberty™) in patients with PNAR. METHODS: In this retrospective cohort study, patients were categorized into pacemaker and non-pacemaker groups based on their need for new postoperative permanent pacemaker implantation (PPI). Based on the postoperative presence of either new-onset complete left bundle branch block (cLBBB) or high-grade atrioventricular block (AVB), patients were further classified into conduction disorder and non-conduction disorder groups. Laboratory, echocardiographic, computed tomography, preoperative and postoperative electrocardiography, and procedural and clinical data were collected immediately after TAVR and during hospitalization and compared between the groups. Multivariate logistic regression analysis was performed incorporating the significant variables from the univariate analyses. RESULTS: This study examined 68 consecutive patients with severe PNAR who underwent TAVR. In 20 patients, a permanent pacemaker was fitted postoperatively. Multivariate logistic regression analysis revealed an association between the need for postoperative PPI and preoperative complete right bundle branch block (cRBBB) or first-degree AVB, as well as a non-tubular left ventricular outflow tract (LVOT). In addition, valve implantation depth and angle of aortic root were independent predictors of new-onset cLBBB or high-grade AVB developing post-TAVR. The predictive value of valve implantation depth and angle of aortic root was further supported by receiver operating characteristic curve analysis results. CONCLUSIONS: In patients with PNAR undergoing TAVR using self-expanding valves, preoperative cRBBB or first-degree AVB and a non-tubular LVOT were indicators of a higher likelihood of PPI requirement. Moreover, deeper valve implantation depth and greater angle of aortic root may be independent risk factors for new-onset cLBBB or high-grade AVB post-TAVR. Valve implantation depth and angle of aortic root values may be used to predict the possibility of new cLBBB or high-grade AVB post-TAVR.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Bloqueo Atrioventricular , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Estudios Retrospectivos , Estimulación Cardíaca Artificial/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Resultado del Tratamiento , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia , Marcapaso Artificial/efectos adversos , Arritmias Cardíacas , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/etiología , Bloqueo de Rama/terapia , Factores de Riesgo , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...