Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Prosthet Dent ; 117(1): 158-163, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27475916

RESUMEN

STATEMENT OF PROBLEM: The changes that occur after brushing yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) are unknown. These changes may favor the retention of microorganisms and chemisorption of water, impairing its longevity. OBJECTIVE: The purpose of this in vitro study was to evaluate the effects of a whitening dentifrice on Y-TZP surfaces after simulating 10 years of brushing. MATERIAL AND METHODS: Seventy-two bar-shaped specimens (20×4×1.2 mm) were divided into 4 groups: storage in distilled water (SW, control), brushing with distilled water (BW), brushing with dentifrice (BD), and brushing with whitening dentifrice (BWD). Brushing was conducted using a linear brushing machine (878400 cycles, 0.98 N, soft toothbrush). The mean roughness (Ra) was analyzed with a profilometer and the superficial topography with scanning electron microscopy (SEM) at baseline and after treatment. Crystalline phases were characterized using x-ray diffraction. Baseline and posttreatment Ra were analyzed using the 1-way ANOVA and Tukey HSD multiple comparison test; the paired t test was used for intragroup comparison (all α=.05). RESULTS: The Ra (µm) means (before/after treatment) were SW 0.28/0.28; BW 0.32/0.31; BD 0.28/0.36; BWD 0.30/0.20. No statistically significant difference was found for Ra at baseline (P=.108) than for posttreatment results (P<.001); the BD group had higher Ra values when compared with baseline (P=.019); the BWD group had the lowest values (P<.001). The BD surfaces showed pronounced scratches and detachment of the surface, while BWD showed smoother surfaces; similar crystallographic results among groups were observed. CONCLUSIONS: Brushing Y-TZP with conventional dentifrice increased roughness, while brushing with whitening dentifrice reduced roughness. Neither dentifrice changed the crystallographic phases after brushing.


Asunto(s)
Dentífricos/efectos adversos , Cepillado Dental/efectos adversos , Itrio , Circonio , Técnicas In Vitro , Propiedades de Superficie , Itrio/normas , Circonio/normas
2.
J Prosthet Dent ; 117(1): 150-157, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27460318

RESUMEN

STATEMENT OF PROBLEM: Indirect composite resins (ICR) are promising alternatives as veneering materials for zirconia frameworks. The effects of core-to-dentin thickness ratio (C/Dtr) on the mechanical property of bilayered veneer ICR/yttria-tetragonal zirconia polycrystalline (Y-TZP) core disks have not been previously studied. PURPOSE: The purpose of this in vitro study was to assess the effects of C/Dtr on the biaxial flexural strength, reliability, and fracture mode of bilayered veneer ICR/ Y-TZP core disks. MATERIAL AND METHODS: A total of 180 bilayered 0.6-mm-thick composite resin disks in core material and C/Dtr of 2:1, 1:1, and 1:2 were tested with either core material placed up or placed down for piston-on-3-ball biaxial flexural strength. The mean biaxial flexural strength, Weibull modulus, and fracture mode were measured to evaluate the variation trend of the biaxial flexural strength, reliability, and fracture mode of the bilayered disks with various C/Dtr. One-way analysis of variance (ANOVA) and chi-square tests were used to evaluate the variation tendency of fracture mode with the C/Dtr or material placed down during testing (α=.05). Light microscopy was used to identify the fracture mode. RESULTS: The mean biaxial flexural strength and reliability improved with the increase in C/Dtr when specimens were tested with the core material either up and down, and depended on the materials that were placed down during testing. The rates of delamination, Hertzian cone cracks, subcritical radial cracks, and number of fracture fragments partially depended on the C/Dtr and the materials that were placed down during testing. CONCLUSION: The biaxial flexural strength, reliability, and fracture mode in bilayered structures of Y-TZP core and veneer ICR depend on both the C/Dtr and the material that was placed down during testing.


Asunto(s)
Resinas Compuestas/uso terapéutico , Coronas con Frente Estético , Itrio/uso terapéutico , Circonio/uso terapéutico , Resinas Compuestas/normas , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Dentina , Humanos , Técnicas In Vitro , Resistencia a la Tracción , Itrio/normas , Circonio/normas
3.
Appl Radiat Isot ; 85: 87-91, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24389532

RESUMEN

In this paper, a method for production of yttrium silicate microspheres is reported. Yttrium silicate microspheres with approximate sizes of 20-50µm were obtained when an aqueous solution of Y(NO3)3 was added to tetraethyl orthosilicate (TEOS) and was pumped into silicone oil under constant stirring. The shapes of the particles produced by the proposed method were regular and nearly spherical. The spherical shapes, composition and element distribution were investigated by scanning electron microscopy (SEM), carbon/sulfur analysis and SEM/EDS mapping analysis. Paper chromatography was used to identify radiochemical impurities in the radioactive microspheres. The radionuclide purity was determined using a gamma spectrometry system and an ultra-low-level liquid scintillation spectrometer. The results indicated that the proposed silicone oil spheroidization method is suitable for the production of yttrium silicate microspheres.


Asunto(s)
Radiofármacos/aislamiento & purificación , Radiofármacos/normas , Radioisótopos de Itrio/aislamiento & purificación , Radioisótopos de Itrio/normas , Braquiterapia , Humanos , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundario , Microscopía Electrónica de Rastreo , Microesferas , Tamaño de la Partícula , Control de Calidad , Radiofármacos/administración & dosificación , Silicatos/aislamiento & purificación , Silicatos/normas , Itrio/aislamiento & purificación , Itrio/normas , Radioisótopos de Itrio/administración & dosificación
4.
Oper Dent ; 39(3): E118-27, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24299447

RESUMEN

This study compares the bond strength of resin cement and yttrium-stabilized tetragonal zirconia polycrystalline (Y-TZP) ceramic with different surface conditioning methods. Two hundred presintered Y-TZP ceramic specimens were prepared, sintered (4 × 4 × 4 mm), and randomly assigned to four equal groups as control (C, no conditioning); airborne particle abraded (APA, air abrasion with 11 µm Al2O3); tribochemical silica coating/silane coupling system (TSC, Rocatec, air abrasion with 110 µm Al2O3, 30 µm silica-coated Al2O3 and silane); and laser (L, Er:YAG laser irradiation treated at a power setting of 200 mJ). After specimen preparation, composite resin cylinders were prepared and cemented with resin cements (Clearfil Esthetic, Panavia F 2.0, Rely X-U100, Super Bond C&B, and Multilink Automix) on the ceramic surfaces and kept in an incubator at 37°C for 60 days. All specimens were tested for shear bond strength with a universal testing machine, and fractured surfaces were evaluated by environmental scanning electron microscopy. Statistical analysis was performed using Kruskal-Wallis and Mann-Whitney U-tests (α=0.05). The bond strengths for C and L groups were not significantly different according to adhesive resin cement. APA and TSC resulted in increased bond strength for Panavia F 2.0 and Rely X-U100 resin cements. Additionally, TSC presented higher bond strength with Multilink Automix. Adhesive fracture between the ceramic and resin cement was the most common failure. Complete cohesive fracture at the ceramic or composite cylinders was not observed. Regardless of the adhesive resin cement used, laser treatment did not improve resin bond strength.


Asunto(s)
Recubrimiento Dental Adhesivo/métodos , Porcelana Dental/uso terapéutico , Cementos de Resina/uso terapéutico , Itrio/uso terapéutico , Circonio/uso terapéutico , Resinas Compuestas/normas , Resinas Compuestas/uso terapéutico , Recubrimiento Dental Adhesivo/normas , Porcelana Dental/normas , Análisis del Estrés Dental , Cementos de Ionómero Vítreo/normas , Cementos de Ionómero Vítreo/uso terapéutico , Humanos , Cementos de Resina/normas , Resistencia a la Tracción , Itrio/normas , Circonio/normas
5.
BMC Musculoskelet Disord ; 14: 154, 2013 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-23634809

RESUMEN

BACKGROUND: Zirconia was introduced as an alternative to alumina for use in the femoral head. The yttria stabilized zirconia material was improved by adding alumina. We evaluated highly cross-linked polyethylene wear performance of zirconia in total hip arthroplasty. The hypothesis was that alumina stabilized zirconia could decrease highly cross-linked polyethylene wear. METHODS: Highly cross-linked polyethylene wear was measured with a computerized method (PolyWare) in 91 hips. The steady-state wear rates were measured based on the radiographs from the first year postoperatively to the final follow-up and were compared between hips with yttria stabilized zirconia and alumina stabilized zirconia. RESULTS: The steady-state wear rate of highly cross-linked polyethylene against zirconia was 0.02 mm/year at a mean follow-up of 7 years. No significant difference was observed between groups with yttria stabilized zirconia and alumina stabilized zirconia. CONCLUSIONS: Addition of alumina to the zirconia material failed to show further reduction of highly cross-linked polyethylene wear and our hypothesis was not verified.


Asunto(s)
Óxido de Aluminio/normas , Prótesis de Cadera/normas , Polietileno/normas , Itrio/normas , Circonio/normas , Adulto , Anciano , Anciano de 80 o más Años , Óxido de Aluminio/química , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Polietileno/química , Diseño de Prótesis/normas , Adulto Joven , Itrio/química , Circonio/química
6.
Asian Pac J Trop Med ; 5(5): 402-5, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22546659

RESUMEN

OBJECTIVE: To evaluate the shear bond strength (SBS) between alumina-toughened zirconia (ATZ) cores and veneering ceramics, investigate the effect of aging in artificial saliva on SBS and compare it with that of yttria-stabilized tetragonal zirconia polycrystals(Y-TZP). METHODS: Bars of ATZ and Y-TZP were layered with veneering ceramics in accordance to the recommendation of the manufacturer. Half of each group (n = 10) was aged at 134 °C (under 2 bar pressure) in an autoclave for 48 h. Subsequently, all specimens were subjected to shear force in a universal testing machine. The interface and fractured surface of the specimens were evaluated using scanning electron microscopy and X-ray energy dispersive spectroscopy. RESULTS: The initial mean SBS values in MPa±SD were 28.9±8.0 for ATZ and 26.2±7.6 for Y-TZP. After aging, the mean SBS values for ATZ and Y-TZP were 22.9±4.9 MPa and 22.8±6.9 MPa, respectively. Neither the differences between the SBS values of the ATZ and Y-TZP groups nor the influence of aging on all groups were statistically significant. CONCLUSIONS: The SBS between the ATZ core and the veneering ceramics was not affected by aging. The SBS of ATZ to veneering ceramics was not significantly different compared with that of Y-TZP.


Asunto(s)
Óxido de Aluminio/normas , Cerámica/normas , Coronas con Frente Estético/normas , Resistencia al Corte , Circonio/normas , Microscopía Electrónica de Rastreo , Falla de Prótesis , Saliva Artificial/farmacología , Análisis Espectral , Itrio/normas
7.
J Biomed Mater Res B Appl Biomater ; 72(2): 239-45, 2005 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-15654702

RESUMEN

Since the recent failure events of two particular series of zirconia femoral heads for total hip replacement prosthesis, a large decrease in the use of zirconia ceramics for orthopaedic implants has been observed. In spite of the biomedical success of this material during the last 10 years, this decrease in use was required for safety reasons, until the cause of the failures is known. It has been shown that these failures were related to the low temperature hydrothermal degradation (also known as aging). Thus, it is crucial to better understand the aging behavior, in order to be able to assess its importance and then control it if required. In this study, various techniques relevant to assess the hydrothermal degradation sensitivity of biomedical grade yttria-stabilized zirconia are discussed and compared. The expected outputs of conventional methods, that is, X-ray diffraction and scanning electron microscopy are examined. More recent methods like optical interferometry and atomic force microscopy are presented, with their respective benefits and drawbacks. An up-to-date comparison of these different techniques is provided, and their use for ensuring the long-term reliability of a particular batch of zirconia in terms of aging degradation is demonstrated.


Asunto(s)
Porcelana Dental/normas , Ensayo de Materiales/métodos , Itrio/normas , Biodegradación Ambiental , Interferometría , Ensayo de Materiales/normas , Métodos , Microscopía de Fuerza Atómica , Microscopía Electrónica de Rastreo , Factores de Tiempo , Difracción de Rayos X , Circonio
8.
J Biomed Mater Res B Appl Biomater ; 72(2): 388-92, 2005 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-15551260

RESUMEN

The strength degrading effects of sharp-contact damage are examined for Y-TZP ceramic plates bonded to a plastic substrate. Contacts are made with Vickers and Berkovich diamond indenters at low loads (0.1 N to 100 N) in the ceramic lower surfaces prior to bonding to the substrates. The indentations remain in the subthreshold region, that is, without visible corner radial cracks, over the lower region (< 10 N) of the load range. A concentrated load is then applied sinusoidally to the ceramic upper surface, with the loading axis centered on the subsurface indentation flaw, thereby subjecting the flaw to cyclic tension. Relative to polished surfaces, the indentations diminish the single-cycle strength by an amount that increases with increasing indentation load. The critical number of cycles required to cause failure from the indentation flaws is then measured at specified maximum lower surface tensile stresses. At each indentation load, the strength of the ceramic plates diminishes with increased cycling. The scale of degradation is compared with that from previous studies on Y-TZP surfaces containing larger-scale surface damage: sandblast damage, as used in dental crown preparation; and blunt-contact trauma from a spherical indenter at 3000 N. These other damage modes are shown to be equivalent in their strength-degrading capacity to diamond pyramid indentations in the microscale load range 0.1 N to 1 N, attesting to the highly deleterious nature of sharp particulate contacts. The mechanism of fatigue is considered in terms of microcrack evolution within the indentation damage zone.


Asunto(s)
Análisis de Falla de Equipo/métodos , Itrio/normas , Circonio/normas , Mecánica , Microscopía de Fuerza Atómica , Falla de Prótesis , Propiedades de Superficie
9.
Gig Tr Prof Zabol ; (3): 39-41, 1991.
Artículo en Ruso | MEDLINE | ID: mdl-1879738

RESUMEN

To measure the concentrations of yttrium-oxide-coated small-dispersed silicon nitride plasma powder, the air was aspirated at the amount of 10-15 litres per min through the AFA-XP filter. The filter was limed in a platinum crucible, the residuum being alloyed with Na2CO3, Na2B4O7, NaNO3 in ratio 10:5:1. The alloy was transferred into solution in which the silicon content was assessed through reactions with ammonium molybdate, and yttrium--through reactions with arsenaso III. The sensibility rate for silicon was at 0.07 mg/m3.


Asunto(s)
Contaminantes Ocupacionales del Aire/toxicidad , Industria Química/normas , Compuestos de Silicona , Silicio/toxicidad , Itrio/toxicidad , Contaminantes Ocupacionales del Aire/análisis , Filtración/métodos , Humanos , Concentración Máxima Admisible , Fotometría/métodos , Silicio/análisis , Silicio/normas , U.R.S.S. , Itrio/análisis , Itrio/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...