Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Int J Biol Macromol ; 270(Pt 1): 132221, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38729499

RESUMEN

Cellulose acetate (CA) is a non-toxic, renewable, and biodegradable polymeric material that can be effectively electrospuned into bacterial filtration efficient nanofiber membrane for face mask application. However, its fragile and non-antibacterial nature influenced its scalability. In this context, natural antibacterial gum rosin (GR) additive can be explored. Therefore, the present study aimed to produce a CA/GR composite nanofibers membrane for the finest bacterial filtration, excellent antibacterial moiety, and improved tensile properties for facemask application. Hence, in this work, we have studied the effect of GR concentrations (0-15 g) on the needleless electrospinning behavior and fibers' morphology through rheology, electrical conductivity, and SEM analysis. These analyses revealed that GR significantly affects the fibers' spinning behavior, morphology, and diameter of the produced fibers. Later, ATR-FTIR spectroscopy mapped the functional changes in the produced nanofibers that affirmed the integration of GR with CA polymer. This modification resulted in a 3-fold rise in tensile strength and an 11-fold decline in elongation% in 15 g CA/GR composite nanofibers membrane than the control sample. Furthermore, it has shown 98.79 ± 0.10% bacterial filtration efficiency and âˆ¼ 93 % reduction in Staphylococcus Aureus and Klebsiella Pneumoniae bacterial growth, elucidating a high-efficiency level for potential facemask application.


Asunto(s)
Antibacterianos , Bacterias , Celulosa , Máscaras , Nanofibras , Resinas de Plantas , Antibacterianos/farmacología , Bacterias/efectos de los fármacos , Conductividad Eléctrica , Filtración/métodos , Filtración/normas , Máscaras/microbiología , Máscaras/normas , Nanofibras/química , Nanofibras/microbiología , Nanofibras/ultraestructura , Resinas de Plantas/química , Reología , Celulosa/análogos & derivados , Celulosa/química , Celulosa/farmacología
2.
Antimicrob Resist Infect Control ; 10(1): 114, 2021 08 05.
Artículo en Inglés | MEDLINE | ID: mdl-34353356

RESUMEN

BACKGROUND: In healthcare facilities, nosocomial transmissions of respiratory viruses are a major issue. SARS-CoV-2 is not exempt from nosocomial transmission. Our goals were to describe COVID-19 nosocomial cases during the first pandemic wave among patients in a French university hospital and compliance with hygiene measures. METHODS: We conducted a prospective observational study in Grenoble Alpes University Hospital from 01/03/2020 to 11/05/2020. We included all hospitalised patients with a documented SARS-CoV-2 diagnosis. Nosocomial case was defined by a delay of 5 days between hospitalisation and first symptoms. Hygiene measures were evaluated between 11/05/2020 and 22/05/2020. Lockdown measures were effective in France on 17/03/2020 and ended on 11/05/2020. Systematic wearing of mask was mandatory for all healthcare workers (HCW) and visits were prohibited in our institution from 13/03/2021 and for the duration of the lockdown period. RESULTS: Among 259 patients included, 14 (5.4%) were considered as nosocomial COVID-19. Median time before symptom onset was 25 days (interquartile range: 12-42). Eleven patients (79%) had risk factors for severe COVID-19. Five died (36%) including 4 deaths attributable to COVID-19. Two clusters were identified. The first cluster had 5 cases including 3 nosocomial acquisitions and no tested HCWs were positive. The second cluster had 3 cases including 2 nosocomial cases and 4 HCWs were positive. Surgical mask wearing and hand hygiene compliance were adequate for 95% and 61% of HCWs, respectively. CONCLUSIONS: The number of nosocomial COVID-19 cases in our hospital was low. Compliance regarding mask wearing, hand hygiene and lockdown measures drastically reduced transmission of the virus. Monitoring of nosocomial COVID-19 cases during the first wave enabled us to determine to what extent the hygiene measures taken were effective and patients protected. Trial registration Study ethics approval was obtained retrospectively on 30 September 2020 (CECIC Rhône-Alpes-Auvergne, Clermont-Ferrand, IRB 5891).


Asunto(s)
COVID-19/epidemiología , Infección Hospitalaria/epidemiología , SARS-CoV-2/aislamiento & purificación , Anciano , Anciano de 80 o más Años , COVID-19/diagnóstico , COVID-19/virología , Prueba de COVID-19/métodos , Infección Hospitalaria/virología , Femenino , Francia/epidemiología , Higiene de las Manos/métodos , Personal de Salud , Hospitales Universitarios/estadística & datos numéricos , Humanos , Control de Infecciones/métodos , Masculino , Máscaras/microbiología , Persona de Mediana Edad , Pandemias , Estudios Prospectivos , Estudios Retrospectivos
3.
PLoS One ; 16(5): e0251872, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34010337

RESUMEN

BACKGROUND: As the SARS-CoV-2 pandemic accelerates, the supply of personal protective equipment remains under strain. To combat shortages, re-use of surgical masks and filtering facepiece respirators has been recommended. Prior decontamination is paramount to the re-use of these typically single-use only items and, without compromising their integrity, must guarantee inactivation of SARS-CoV-2 and other contaminating pathogens. AIM: We provide information on the effect of time-dependent passive decontamination (infectivity loss over time during room temperature storage in a breathable bag) and evaluate inactivation of a SARS-CoV-2 surrogate and a non-enveloped model virus as well as mask and respirator integrity following active multiple-cycle vaporised hydrogen peroxide (VHP), ultraviolet germicidal irradiation (UVGI), and dry heat (DH) decontamination. METHODS: Masks and respirators, inoculated with infectious porcine respiratory coronavirus or murine norovirus, were submitted to passive decontamination or single or multiple active decontamination cycles; viruses were recovered from sample materials and viral titres were measured via TCID50 assay. In parallel, filtration efficiency tests and breathability tests were performed according to EN standard 14683 and NIOSH regulations. RESULTS AND DISCUSSION: Infectious porcine respiratory coronavirus and murine norovirus remained detectable on masks and respirators up to five and seven days of passive decontamination. Single and multiple cycles of VHP-, UVGI-, and DH were shown to not adversely affect bacterial filtration efficiency of masks. Single- and multiple UVGI did not adversely affect respirator filtration efficiency, while VHP and DH induced a decrease in filtration efficiency after one or three decontamination cycles. Multiple cycles of VHP-, UVGI-, and DH slightly decreased airflow resistance of masks but did not adversely affect respirator breathability. VHP and UVGI efficiently inactivated both viruses after five, DH after three, decontamination cycles, permitting demonstration of a loss of infectivity by more than three orders of magnitude. This multi-disciplinal approach provides important information on how often a given PPE item may be safely reused.


Asunto(s)
COVID-19/metabolismo , Descontaminación/métodos , Peróxido de Hidrógeno/farmacología , Norovirus/efectos de los fármacos , Equipo de Protección Personal/provisión & distribución , SARS-CoV-2/efectos de los fármacos , Antiinfecciosos/farmacología , COVID-19/epidemiología , COVID-19/virología , Equipo Reutilizado , Calor , Humanos , Máscaras/microbiología , Norovirus/aislamiento & purificación , Pandemias , Equipo de Protección Personal/microbiología , Dispositivos de Protección Respiratoria/microbiología , SARS-CoV-2/aislamiento & purificación , Rayos Ultravioleta , Terapia Ultravioleta , Ventiladores Mecánicos/microbiología , Volatilización
4.
Retina ; 41(11): 2215-2220, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-33965993

RESUMEN

PURPOSE: To investigate the bacterial growth in the surgical face masks used by patients who received intravitreal injections and study the effect of povidone-iodine on the periocular area (PA) of masks. METHODS: Forty patients who attended for intravitreal injections were divided in those with less (<4 hours) and more (>4 hours) than 4 hours of mask use. Each group was divided depending on the application or not of povidone-iodine in the PA of the mask. Bacterial load was studied on PA and mouth area samples. RESULTS: The bacterial load in the PA was higher in the >4 hours group compared with the <4 hours group (13.2 vs. 48.75 colony-forming units/µL; P = 0.03). The contamination in the PA significantly decreased after applying povidone-iodine in the >4 hours group (P = 0.01). The use or not of povidone-iodine was strongly correlated to a positive culture (OR = 9.0, P = 0.00. CI 1.63-49.44). CONCLUSION: Surgical face masks worn for more than 4 hours present higher contamination in the PA than those with less use. Bacterial load in the PA is reduced with povidone-iodine on masks used for more than 4 hours. This contamination should be considered in the asepsis protocol of intravitreal injections.


Asunto(s)
Inhibidores de la Angiogénesis/administración & dosificación , Bacterias/aislamiento & purificación , COVID-19/epidemiología , Contaminación de Equipos , Máscaras/microbiología , SARS-CoV-2 , Anciano , Anciano de 80 o más Años , Antiinfecciosos Locales/administración & dosificación , Carga Bacteriana , Técnicas Bacteriológicas , Femenino , Humanos , Inyecciones Intravítreas , Masculino , Persona de Mediana Edad , Povidona Yodada/administración & dosificación , Estudios Prospectivos , Enfermedades de la Retina/tratamiento farmacológico , Factor A de Crecimiento Endotelial Vascular/antagonistas & inhibidores
5.
Sci Rep ; 11(1): 5887, 2021 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-33723303

RESUMEN

Based on the current knowledge of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) transmission, wearing a mask has been recommended during the COVID-19 pandemic. Bacterial filtration efficiency (BFE) measurements enable designing and regulating medical masks to prevent bioaerosol dissemination; however, despite the simplicity of these measurements, several scientific questions remain unanswered regarding BFE tests. Here, we investigated (1) the impact of substituting 100-mm Petri dishes with 90-mm disposable Petri dishes, (2) the impact of colony-counting methods on the bioaerosol aerodynamic size, and (3) the impact of colony-counting methods on the total viable particle counts. We demonstrated that disposable 90-mm Petri dishes can be used to replace the 100-mm dishes. We also showed that an automatic high-resolution colony counter can be used to directly count viable particles on collection substrates and to measure the bioaerosol size parameters. Our results enable possible modernization of the outdated testing methods recommended in the US and European standards for BFE measurements. Specifically, use of a modernized colony counter should be clearly regulated and permitted to avoid the counting of positive holes. The median aerodynamic diameter appears to be the most relevant parameter for characterizing bioaerosol size.


Asunto(s)
Bacterias , Filtración/normas , Máscaras/normas , Carga Bacteriana , Microbiología Ambiental , Filtración/métodos , Humanos , Máscaras/microbiología , Tamaño de la Partícula , Porosidad
6.
J Prev Med Public Health ; 54(1): 31-36, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33618497

RESUMEN

OBJECTIVES: Non-traditional materials are used for mask construction to address personal protective equipment shortages during the coronavirus disease 2019 (COVID-19) pandemic. Reusable masks made from surgical sterilization wrap represent such an innovative approach with social media frequently referring to them as "N95 alternatives." This material was tested for particle filtration efficiency and breathability to clarify what role they might have in infection prevention and control. METHODS: A heavyweight, double layer sterilization wrap was tested when new and after 2, 4, 6, and 10 autoclave sterilizing cycles and compared with an approved N95 respirator and a surgical mask via testing procedures using a sodium chloride aerosol for N95 efficiency testing similar to 42 CFR 84.181. Pressure testing to indicate breathability was also conducted. RESULTS: The particle filtration efficiency for the sterilization wrap ranged between 58% to 66%, with similar performance when new and after sterilizing cycles. The N95 respirator and surgical mask performed at 95% and 68% respectively. Pressure drops for the sterilization wrap, N95 and surgical mask were 10.4 mmH2O, 5.9 mmH2O, and 5.1 mmH2O, respectively, well below the National Institute for Occupational Safety and Health limits of 35 mmH2O during initial inhalation and 25 mmH2O during initial exhalation. CONCLUSIONS: The sterilization wrap's particle filtration efficiency is much lower than a N95 respirator, but falls within the range of a surgical mask, with acceptable breathability. Performance testing of non-traditional mask materials is crucial to determine potential protection efficacy and for correcting misinterpretation propagated through popular media.


Asunto(s)
Filtración/normas , Máscaras/normas , Filtración/instrumentación , Filtración/estadística & datos numéricos , Humanos , Máscaras/microbiología , Máscaras/virología , Exposición Profesional/prevención & control , Pandemias/prevención & control , Equipo de Protección Personal/normas , Equipo de Protección Personal/estadística & datos numéricos , Esterilización/métodos , Esterilización/normas , Esterilización/estadística & datos numéricos
8.
ACS Appl Mater Interfaces ; 13(2): 2483-2495, 2021 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-33404219

RESUMEN

Influenza, pneumonia, and pathogenic infection of the respiratory system are boosted in cold environments. Low temperatures also result in vasoconstriction, restraint of blood flow, and decreased oxygen to the heart, and the risk of a heart attack would increase accordingly. The present face mask fabric fails to preserve its air-filtering function as its electrostatic function vanishes once exposed to water. Therefore, its filtering efficacy would be decreased meaningfully, making it nearly impracticable to reuse the disposable face masks. The urgent requirement for photothermal fabrics is also rising. Nanobased polyethyleneimine-polypyrrole nanopigments (NPP NPs) have been developed and have strong near-infrared spectrum absorption and exceptional photothermal convertible performance. Herein, the mask fabric used PE-fiber-constructed membrane (PEFM) was coated by the binding affinity of the cationic polyethyleneimine component of NPP NPs forming NPP NPs-PEFM. To the best of our knowledge, no study has investigated NPP NP-coated mask fabric to perform infrared red (solar or body) photothermal conversion efficacy to provide biocompatible warming, remotely photothermally captured antipathogen, and antivasoconstriction in vivo. This pioneering study showed that the developed NPP NPs-PEFM could be washable, reusable, breathable, biocompatible, and photothermal conversable for active eradication of pathogenic bacteria. Further, it possesses warming preservation and antivasoconstriction.


Asunto(s)
Materiales Biocompatibles Revestidos/química , Nanoestructuras/química , Polietileno/química , Polietileneimina/química , Polímeros/química , Pirroles/química , Textiles/análisis , Animales , Antibacterianos/química , Rayos Infrarrojos , Máscaras/microbiología , Nanoestructuras/ultraestructura , Procesos Fotoquímicos , Conejos , Ratas , Temperatura , Textiles/microbiología
9.
ACS Nano ; 14(10): 13161-13171, 2020 10 27.
Artículo en Inglés | MEDLINE | ID: mdl-32975412

RESUMEN

The regeneration of filtering facepiece respirators (FFRs) is of critical importance because of the severe shortage of FFRs during large-scale outbreaks of respiratory epidemics, such as COVID-19. Comprehensive experiments regarding FFR regeneration were performed in this study with model bacteria to illustrate the decontamination performance of the regeneration processes. The results showed that it is dangerous to use a contaminated FFR without any microbe inactivation treatment because the bacteria can live for more than 8 h. The filtration efficiency and surface electrostatic potential of 75% ethanol-treated FFRs were significantly reduced, and a most penetrating particle size of 200 nm was observed. Steam and microwave irradiation (MWI) showed promising decontamination performances, achieving 100% inactivation in 90 and 30 min, respectively. The filtration efficiencies of steam-treated FFRs for 50 and 100 nm particles decreased from 98.86% and 99.51% to 97.58% and 98.79%, respectively. Ultraviolet irradiation (UVI) effectively inactivated the surface bacteria with a short treatment of 5 min and did not affect the filtration performance. However, the UV dose reaching different layers of the FFP2 mask sample gradually decreased from the outermost layer to the innermost layer, while the model bacteria on the second and third layers could not be killed completely. UVI+MWI and steam were recommended to effectively decontaminate the used respirators and still maintain the respirators' filtration efficiency. The present work provides a comprehensive evaluation for FFR regeneration in terms of the filtration efficiencies for 50-500 nm particles, the electrostatic properties, mechanical properties, and decontamination effects.


Asunto(s)
Bacterias/efectos de la radiación , Desinfección/métodos , Máscaras/microbiología , Dispositivos de Protección Respiratoria/microbiología , Bacterias/efectos de los fármacos , Bacterias/patogenicidad , Desinfección/normas , Etanol/toxicidad , Filtración , Humanos , Máscaras/normas , Microondas , Dispositivos de Protección Respiratoria/normas , Vapor , Textiles/microbiología , Textiles/normas , Rayos Ultravioleta
10.
J Med Imaging Radiat Sci ; 51(4): 590-598, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32948475

RESUMEN

BACKGROUND: Thermoplastic immobilization masks used during radiation therapy treatment have been shown to harbor several different types of bacteria. Recovered bacteria included Staphylococcus aureus, Enterococcus species, Gram-negative rods, coagulase-negative staphylococci, and several different Bacillus species. Two of the recovered Bacillus bacteria were examined for their ability to attach to and survive over time on patient head-only masks from four different manufacturers. B. halosaccharovorans was recovered from a treatment facility's water bath while B. cereus was recovered from a patient mask in the same facility. Bacillus bacteria were chosen for this study due to their capability to form dormant spores. METHODS: Inoculums containing either B. halosaccharovorans or B. cereus bacteria were seeded onto predesignated areas of each test mask. Masks were subsequently sampled at intervals of 1-h, 1 week, 2 weeks, 3 weeks, and 4 weeks. Recovered bacterial numbers at each sampling interval were determined using the direct plate count method. Spore stains were made of both bacterial isolates and number of detected spores were enumerated. RESULTS: B. halosaccharovorans attached to each mask type after a 1-h contact time at a number 3X greater than B. cereus. B. halosaccharovorans was also recovered at a number 8.5X greater than B. cereus after 4 weeks. Variation was seen in the attachment capability of each bacterium on tested mask types. Both bacilli were recovered from all 4 masks at each sampling interval including week 4. Examination of spore stains of each bacteria demonstrated nearly a 25:1 ratio of B. halosaccharovorans spores over B. cereus. DISCUSSION: The large variation seen between B. halosaccharovorans and B. cereus capability to attach to each of the four tested masks is revealing, especially when it is combined with determined spore numbers. It suggests that spores play a role in mediating their attachment to mask surfaces. Moreover, the recovery of both bacteria from stored masks after 4 weeks indicates a continued presence of dormant spores since growth-supportive nutrients are lacking. It also implies the potential for their transfer to a patient wearing a contaminated mask during a treatment session. CONCLUSION: The demonstrated ability of these two Bacillus bacteria to attach to and reside on patient masks presents a dilemma. Routine cleaning with approved disinfectants may not be sufficient to eliminate dormant spores on masks surfaces. This matter requires further investigation. For now, a small modification to the routine mask cleaning procedure before its application may help to reduce the possibility of spore transfer.


Asunto(s)
Bacillus cereus/crecimiento & desarrollo , Bacillus cereus/aislamiento & purificación , Bacillus/crecimiento & desarrollo , Bacillus/aislamiento & purificación , Máscaras/microbiología , Radioterapia/instrumentación , Recuento de Colonia Microbiana , Inmovilización/instrumentación
11.
Microbiol Res ; 241: 126587, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32927205

RESUMEN

Novel sampling matrices were manufactured using 3D printing for the detection of respiratory pathogens in expired air. A specific configuration of the matrices was designed using Computer-Aided Design software. Polyvinyl alcohol (PVA) was printed using fused deposition modelling to create a multilayer matrix to enhance the capture of bacteria. The performance of these matrices was compared with gelatine filters that have been used for this work to date. PVA matrices (60 mm diameter) were contaminated with bacteria either by direct inoculation, or by aerosol exposure using an Omron A3 nebuliser. Rough and smooth morphotypes of Mycobacterium abscessus, M. smegmatis and M. bovis BCG, were used in this study to contaminate the matrices. PVA matrices and gelatine sampling filters were contaminated to compare recovery rates for quantitative analyses. These were dissolved in water, bacteria pelleted and DNA extracted followed by a Mycobacterium-specific quantitative Polymerase Chain Reaction (qPCR).The results showed that 3D printed PVA matrices are very effective to capture the bacteria. 3D printed PVA matrix and gelatine filters yielded results of the same order of magnitude for mycobacterial analyses, however, PVA matrix offers several advantages over the latter material. 3D printed PVA is considered as an economic and time-effective matrix as it is cheaper than gelatine filters. PVA is sufficiently robust to be handled and loaded into the surgical masks for sampling, compared to the brittle gelatine filters that required supportive frames. PVA is a synthetic material and it is suitable for DNA-based analyses, whilst gelatine is derived from animal collagen, and carries a high bacterial DNA background that interferes with the target DNA analysis. Furthermore, PVA dissolves in distilled water without requiring chemicals or enzymes, such as the case for gelatine hydrolysis. To summarise, 3D printed PVA sampling matrix is considered a promising tool used for microbiological diagnostic purposes.


Asunto(s)
Filtración/métodos , Mycobacterium abscessus/aislamiento & purificación , Mycobacterium bovis/aislamiento & purificación , Mycobacterium smegmatis/aislamiento & purificación , Material Particulado/análisis , Infecciones del Sistema Respiratorio/microbiología , Gelatina , Humanos , Máscaras/microbiología , Alcohol Polivinílico , Impresión Tridimensional , Reacción en Cadena en Tiempo Real de la Polimerasa
12.
Sci Rep ; 10(1): 13875, 2020 08 17.
Artículo en Inglés | MEDLINE | ID: mdl-32807805

RESUMEN

Respiratory protection is key in infection prevention of airborne diseases, as highlighted by the COVID-19 pandemic for instance. Conventional technologies have several drawbacks (i.e., cross-infection risk, filtration efficiency improvements limited by difficulty in breathing, and no safe reusability), which have yet to be addressed in a single device. Here, we report the development of a filter overcoming the major technical challenges of respiratory protective devices. Large-pore membranes, offering high breathability but low bacteria capture, were functionalized to have a uniform salt layer on the fibers. The salt-functionalized membranes achieved high filtration efficiency as opposed to the bare membrane, with differences of up to 48%, while maintaining high breathability (> 60% increase compared to commercial surgical masks even for the thickest salt filters tested). The salt-functionalized filters quickly killed Gram-positive and Gram-negative bacteria aerosols in vitro, with CFU reductions observed as early as within 5 min, and in vivo by causing structural damage due to salt recrystallization. The salt coatings retained the pathogen inactivation capability at harsh environmental conditions (37 °C and a relative humidity of 70%, 80% and 90%). Combination of these properties in one filter will lead to the production of an effective device, comprehensibly mitigating infection transmission globally.


Asunto(s)
Filtros de Aire/microbiología , Antibacterianos/química , Betacoronavirus , Infecciones por Coronavirus/prevención & control , Máscaras/microbiología , Membranas Artificiales , Pandemias/prevención & control , Neumonía Viral/prevención & control , Dispositivos de Protección Respiratoria/microbiología , Cloruro de Sodio/química , Aerosoles , Antibacterianos/farmacología , COVID-19 , Infecciones por Coronavirus/transmisión , Infecciones por Coronavirus/virología , Cristalización , Bacterias Gramnegativas/efectos de los fármacos , Bacterias Grampositivas/efectos de los fármacos , Calor , Humanos , Humedad , Neumonía Viral/transmisión , Neumonía Viral/virología , SARS-CoV-2 , Cloruro de Sodio/farmacología
13.
Am J Infect Control ; 48(9): 1037-1041, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32645473

RESUMEN

INTRODUCTION: One of the serious consequences of the SARS-CoV-2 pandemic is the shortage of protective equipment for health personnel. N95 masks are considered one of the essential protective equipment in the management of patients with COVID-19. The shortage of N95 masks implies potential health risks for health personnel and significant economic losses for the health institution. The objective of this work was to investigate the disinfection of N95 masks artificially contaminated with SARS-CoV-2 and ESKAPE bacteria by using hydrogen peroxide plasma. MATERIAL AND METHODS: We examined the disinfection capacity of hydrogen peroxide plasma against the SARS-CoV-2 and 2 members of the ESKAPE bacteria (Acinetobacter baumannii and Staphylococcus aureus) through a study of artificial contamination in situ of N95 masks. Amplification of specific genes by real-time reverse transcription polymerase chain reaction of SARS-CoV-2 and microbiological culture of ESKAPE bacteria was performed before and after the disinfection process. RESULTS: SARS-CoV-2 was not detected in all assays using 5 different concentrations of the virus, and A baumannii and S aureus were not cultivable with inoculums of 102 to 106 CFU after disinfection tests of N95 masks with hydrogen peroxide plasma. CONCLUSION: Disinfection of N95 masks by using the hydrogen peroxide plasma technology can be an alternative for their reuse in a shortage situation. Implications for the use of disinfection technologies of N95 masks and the safety of health personnel are discussed.


Asunto(s)
Antiinfecciosos Locales/administración & dosificación , Betacoronavirus/efectos de los fármacos , Infecciones por Coronavirus/prevención & control , Desinfección/métodos , Equipo Reutilizado , Peróxido de Hidrógeno/administración & dosificación , Máscaras/microbiología , Pandemias/prevención & control , Neumonía Viral/prevención & control , Acinetobacter baumannii/efectos de los fármacos , COVID-19 , Humanos , Dispositivos de Protección Respiratoria/microbiología , SARS-CoV-2 , Staphylococcus aureus/efectos de los fármacos
14.
Am J Infect Control ; 48(12): 1543-1545, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32682015

RESUMEN

Many healthcare systems have been forced to outsource simple mask production due to international shortages caused by the COVID-19 pandemic. Providence created simple masks using surgical wrap and submitted samples to an environmental lab for bacterial filtration efficiency testing. Bacterial filtration efficiency rates ranged from 83.0% to 98.1% depending on specific material and ply, and particular filtration efficiency rates ranged from 92.3% to 97.7%. Based on mask configuration, specific surgical wrap selected, and ply, the recommended filtration efficiency for isolation and surgical masks of 95% and 98%, respectively can be achieved. These alternative masks can allow for similar coverage and safety when hospital-grade isolation masks are in short supply.


Asunto(s)
COVID-19/prevención & control , Seguridad de Equipos/estadística & datos numéricos , Filtración/instrumentación , Máscaras/microbiología , Dispositivos de Protección Respiratoria/microbiología , SARS-CoV-2 , Microbiología del Aire , Bacterias/aislamiento & purificación , Diseño de Equipo , Humanos , Máscaras/provisión & distribución , Ensayo de Materiales , Material Particulado/aislamiento & purificación , Dispositivos de Protección Respiratoria/provisión & distribución
16.
Lancet Infect Dis ; 20(5): 607-617, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32085847

RESUMEN

BACKGROUND: Tuberculosis remains a global health challenge, with early diagnosis key to its reduction. Face-mask sampling detects exhaled Mycobacterium tuberculosis. We aimed to investigate bacillary output from patients with pulmonary tuberculosis and to assess the potential of face-mask sampling as a diagnostic method in active case-finding. METHODS: We did a 24-h longitudinal study in patients from three hospitals in Pretoria, South Africa, with microbiologically confirmed pulmonary tuberculosis. Patients underwent 1 h of face-mask sampling eight times over a 24-h period, with contemporaneous sputum sampling. M tuberculosis was detected by quantitative PCR. We also did an active case-finding pilot study in inhabitants of an informal settlement near Pretoria. We enrolled individuals with symptoms of tuberculosis on the WHO screening questionnaire. Participants provided sputum and face-mask samples that were tested with the molecular assay Xpert MTB/RIF Ultra. Sputum-negative and face-mask-positive individuals were followed up prospectively for 20 weeks by bronchoscopy, PET-CT, and further sputum analysis to validate the diagnosis. FINDINGS: Between Sept 22, 2015, and Dec 3, 2015, 78 patients with pulmonary tuberculosis were screened for the longitudinal study, of whom 24 completed the study (20 had HIV co-infection). M tuberculosis was detected in 166 (86%) of 192 face-mask samples and 38 (21%) of 184 assessable sputum samples obtained over a 24-h period. Exhaled M tuberculosis output showed no diurnal pattern and did not associate with cough frequency, sputum bacillary content, or chest radiographic disease severity. On May 16, 2018, 45 individuals were screened for the prospective active case-finding pilot study, of whom 20 had tuberculosis symptoms and were willing to take part. Eight participants were diagnosed prospectively with pulmonary tuberculosis, of whom six were exclusively face-mask positive at screening. Four of these participants (three of whom were HIV-positive) had normal findings on chest radiography but had treatment-responsive early tuberculosis-compatible lesions on PET-CT scans, with Xpert-positive sputum samples after 6 weeks. INTERPRETATION: Face-mask sampling offers a highly efficient and non-invasive method for detecting exhaled M tuberculosis, informing the presence of active infection both with greater consistency and at an earlier disease stage than with sputum samples. The approach shows potential for diagnosis and screening, particularly in difficult-to-reach communities. FUNDING: Wellcome Trust, CARA (Council for At-Risk Academics), University of Leicester, the UK Medical Research Council, and the National Institute for Health Research. VIDEO ABSTRACT.


Asunto(s)
Máscaras/microbiología , Mycobacterium tuberculosis/aislamiento & purificación , Tuberculosis Pulmonar/diagnóstico , Tuberculosis Pulmonar/microbiología , Adulto , Coinfección/diagnóstico , Coinfección/microbiología , Coinfección/virología , Pruebas Diagnósticas de Rutina/métodos , Femenino , Infecciones por VIH/microbiología , Infecciones por VIH/virología , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad , Sudáfrica , Esputo/microbiología , Esputo/virología , Adulto Joven
17.
Rev. chil. anest ; 49(4): 464-472, 2020. tab
Artículo en Español | LILACS | ID: biblio-1511692

RESUMEN

In this article, we develop evidence-based recommendations to efficiently administer the limited resources of the healthcare facilities in medium and low income countries in the context of a pandemic. We searched MedLine database using the MeSH terms "Pneumonia, viral/prevention and control", "Pneumonia, viral/transmission", "Coronavirus Infections/prevention and control", "Coronavirus Infections/transmission", "COVID-19", "Masks/classification", "Masks/microbiology", "Respiratory Protective Devices", among others. We recommend that the general population wears a face mask. On the institutional level, ventilation and appropriate bed distancing proved to be effective preventive measures. The most important factor in the containment of an outbreak is the timely identification of infected patients. Negative pressure and ventilation systems are also highly recommended. Using a full face mask together with a surgical mask might be an option to deal with N95 respirators shortage. We present an integral strategy with coping measures for healthcare institutions and the society in general.


Elaboramos recomendaciones basadas en la evidencia para administrar los recursos imprescindibles en los centros sanitarios, en contexto de pandemia, en un país de bajos recursos económicos. Se realizaron búsquedas MedLine utilizando términos MeSH "Pneumonia, viral/prevention and control", "Pneumonia, viral/transmission", "Coronavirus Infections/prevention and control", "Coronavirus Infections/transmission", "COVID-19", "Masks/classification", "Masks/microbiology", "Respiratory Protective Devices", entre otros. Se recomienda que la población general porte mascarilla. A nivel institucional, la ventilación y el correcto distanciamiento de las camas son medidas de prevención efectivas. El factor más importante en la contención de un brote es la identificación oportuna de pacientes infectados. Se recomienda el uso de presión negativa y sistemas de ventilación. Ante la escasez de mascarillas tipo N95, el uso de protectores faciales totales y mascarilla quirúrgica es una opción factible. Proponemos una estrategia integral con medidas de afrontamiento para entidades sanitarias y la sociedad en general.


Asunto(s)
Humanos , COVID-19/prevención & control , COVID-19/transmisión , Dispositivos de Protección Respiratoria , Pandemias , SARS-CoV-2 , Máscaras/clasificación , Máscaras/microbiología
18.
Gastrointest Endosc ; 89(4): 818-824, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30391253

RESUMEN

BACKGROUND AND AIMS: Nonuniversal use of facial protection during endoscopy may place endoscopists at risk of exposure to blood and body fluids; however, the frequency of exposure is unknown. METHODS: A prospective 6-month study of 4 gastroenterologists using a face shield during endoscopy was undertaken. The face shield was swabbed in a standardized fashion before and at the end of the session. Controls included pre- and post-swabs of face shields placed on the (1) endoscopy suite wall, (2) remote patient intake bay wall, and (3) after deliberate contamination with a colonoscope immediately after colonoscopy. The swabs were cultured for 48 hours, and growth was reported as no growth or by number of colony-forming units (CFUs). The groups were compared for +CFU rate and CFU number. RESULTS: A total of 1100 procedures were performed in 239 endoscopy sessions. The +CFU rate in the pre-endoscopy groups (2%-4.8%, not significant) was significantly lower than the postendoscopist face shield (45.8%, P < .001) and endoscopy suite wall groups (21.4%, P < .001), respectively. Using a cut-off of >15 CFUs as an indicator of definite exposure, the occurrence rate was 5.6 per 100 half days of endoscopy to the endoscopist's face and 3.4 per 100 half days of endoscopy 6 feet away. CONCLUSIONS: This is the first study to quantify the rate of unrecognized exposure to the endoscopist's face to potentially infectious biologic samples during endoscopy (5.6/100 days of endoscopy). This exposure may result in transmission of infectious diseases. As such, we recommend the use of universal facial protection during GI endoscopy.


Asunto(s)
Bacterias/aislamiento & purificación , Endoscopía del Sistema Digestivo , Gastroenterólogos , Máscaras/microbiología , Exposición Profesional/estadística & datos numéricos , Actitud del Personal de Salud , Colonoscopía , Recuento de Colonia Microbiana , Técnicas de Cultivo , Endosonografía , Humanos , Incidencia , Estudios Prospectivos
20.
Rev Esp Quimioter ; 28(3): 154-6, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26033000

RESUMEN

INTRODUCTION: Nebulized devices are commonly used in the treatment of respiratory infection, and other respiratory diseases. It has been reported nosocomial infections in cystic fibrosis patients as a result of the use of contaminated devices. However, little is known about nosocomial infections secondary to aerosolized therapy in COPD patients admitted for acute exacerbation. METHODS: Thirty consecutive patients (13 males) were included. All of them received aerosolized medication. Each patient used their own facemask and nebulizer cup, which were stored in the room after its use. Samples from nebulizer cups were obtained on days 0, 4 and 7. In addition, sputum samples were obtained on day 0 (prior to any nebulization) and on day 7, and cultivated in enriched media. RESULTS: Only nine nebulizer cups had positive microbiological cultures. Coagulase negative staphylococci (CoNS) were isolated in all cases. Sputum samples could be obtained in 27 patients. None grew CoNS after 7 days of aerosolized therapy. Gram-negative non-fermenting bacilli were isolated in three patients without concomitant grown in nebulizer cups. CONCLUSIONS: We did not find any nosocomial infection related to aerosolize medications in COPD patients admitted for acute exacerbation.


Asunto(s)
Aerosoles/efectos adversos , Infección Hospitalaria/transmisión , Contaminación de Equipos , Nebulizadores y Vaporizadores , Infecciones del Sistema Respiratorio/transmisión , Staphylococcus/aislamiento & purificación , Administración por Inhalación , Agonistas de Receptores Adrenérgicos beta 2/administración & dosificación , Anciano , Anciano de 80 o más Años , Broncodilatadores/administración & dosificación , Infección Hospitalaria/epidemiología , Infección Hospitalaria/microbiología , Femenino , Bacterias Gramnegativas/aislamiento & purificación , Infecciones por Bacterias Gramnegativas/epidemiología , Infecciones por Bacterias Gramnegativas/microbiología , Hospitales Universitarios/estadística & datos numéricos , Humanos , Masculino , Máscaras/microbiología , Nebulizadores y Vaporizadores/microbiología , Proyectos Piloto , Enfermedad Pulmonar Obstructiva Crónica/tratamiento farmacológico , Infecciones del Sistema Respiratorio/epidemiología , Infecciones del Sistema Respiratorio/microbiología , Piel/microbiología , España/epidemiología , Esputo/microbiología , Infecciones Estreptocócicas/epidemiología , Infecciones Estreptocócicas/microbiología , Streptococcus/aislamiento & purificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA