Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.999
Filtrar
1.
Ann Plast Surg ; 92(4S Suppl 2): S80-S86, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38556652

RESUMEN

INTRODUCTION: Amid rising obesity, concurrent ventral hernia repair and panniculectomy procedures are increasing. Long-term outcomes of transverse abdominis release (TAR) combined with panniculectomy remain understudied. This study compares clinical outcomes and quality of life (QoL) after TAR, with or without panniculectomy. METHODS: A single-center retrospective review from 2016 to 2022 evaluated patients undergoing TAR with and without panniculectomy. Propensity-scored matching was based on age, body mass index, ASA, and ventral hernia working group. Patients with parastomal hernias were excluded. Patient/operative characteristics, postoperative outcomes, and QoL were analyzed. RESULTS: Fifty subjects were identified (25 per group) with a median follow-up of 48.8 months (interquartile range, 43-69.7 months). The median age and body mass index were 57 years (47-64 years) and 31.8 kg/m2 (28-36 kg/m2), respectively. The average hernia defect size was 354.5 cm2 ± 188.5 cm2. There were no significant differences in hernia recurrence, emergency visits, readmissions, or reoperations between groups. However, ventral hernia repair with TAR and panniculectomy demonstrated a significant increase in delayed healing (44% vs 4%, P < 0.05) and seromas (24% vs 4%, P < 0.05). Postoperative QoL improved significantly in both groups (P < 0.005) across multiple domains, which continued throughout the 4-year follow-up period. There were no significant differences in QoL among ventral hernia working group, wound class, surgical site occurrences, or surgical site occurrences requiring intervention (P > 0.05). Patients with concurrent panniculectomy demonstrated a significantly greater percentage change in overall scores and appearance scores. CONCLUSIONS: Ventral hernia repair with TAR and panniculectomy can be performed safely with low recurrence and complication rates at long-term follow-up. Despite increased short-term postoperative complications, patients have a significantly greater improvement in disease specific QoL.


Asunto(s)
Abdominoplastia , Hernia Ventral , Lipectomía , Humanos , Calidad de Vida , Hernia Ventral/cirugía , Abdominoplastia/métodos , Lipectomía/métodos , Complicaciones Posoperatorias/cirugía , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Herniorrafia/métodos , Mallas Quirúrgicas/efectos adversos , Recurrencia
2.
Ann Plast Surg ; 92(4S Suppl 2): S156-S160, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38556666

RESUMEN

INTRODUCTION: The ideal mesh type for hernia repair in a contaminated field remains controversial. Data regarding outcomes beyond 1 year and the impact on quality of life (QoL) are unknown. This study aims to evaluate the long-term surgical outcomes and patient-reported outcomes (PROs) after contaminated repair with poly-4-hydroxybutyrate (P4HB) mesh. MATERIALS METHODS: Patients undergoing a contaminated hernia repair with P4HB between 2015 and 2020 were identified. Surgical site occurrences and hernia recurrences were recorded. Long-term PROs as defined by the Abdominal Hernia-Q and Hernia-Related Quality-of-Life Survey were assessed. RESULTS: Fifty-five patients were included with a mean age of 54.5 years, a body mass index of 34 kg/m2, and a defect size of 356.9 ± 227.7 cm2. Median follow-up time was 49 months with a reoperation rate of 14.5% and a hernia recurrence rate of 7.3%. Of the 55 patients, 37 completed preoperative and postoperative PRO questionnaires. When comparing preoperative with postoperative Abdominal Hernia-Q, there was significant improvement in overall PROs (2.1 vs 3.5, P < 0.001). This improvement was maintained with no significant changes between postoperative scores over the course of 5 years. Patients with complications saw the same improvement in postoperative PRO scores as those without complications. CONCLUSIONS: Our study found a low hernia recurrence and acceptable long-term reoperation rates in patients undergoing hernia repair with P4HB mesh in a contaminated setting. We demonstrate a sustained significant improvement in QoL scores after hernia repair. These data yield insight into the long-term outcomes and QoL improvement, providing physicians further knowledge to better counsel their patients.


Asunto(s)
Hernia Ventral , Hernia Incisional , Humanos , Persona de Mediana Edad , Calidad de Vida , Herniorrafia/efectos adversos , Resultado del Tratamiento , Infección de la Herida Quirúrgica/etiología , Mallas Quirúrgicas/efectos adversos , Hernia Ventral/cirugía , Hernia Incisional/cirugía , Recurrencia , Estudios Retrospectivos
3.
J Urol ; 211(6): 743-753, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38620056

RESUMEN

PURPOSE: We assessed the effect of prophylactic biologic mesh on parastomal hernia (PSH) development in patients undergoing cystectomy and ileal conduit (IC). MATERIALS AND METHODS: This phase 3, randomized, controlled trial (NCT02439060) included 146 patients who underwent cystectomy and IC at the University of Southern California between 2015 and 2021. Follow-ups were physical exam and CT every 4 to 6 months up to 2 years. Patients were randomized 1:1 to receive FlexHD prophylactic biological mesh using sublay intraperitoneal technique vs standard IC. The primary end point was time to radiological PSH, and secondary outcomes included clinical PSH with/without surgical intervention and mesh-related complications. RESULTS: The 2 arms were similar in terms of baseline clinical features. All surgeries and mesh placements were performed without any intraoperative complications. Median operative time was 31 minutes longer in patients who received mesh, yet with no statistically significant difference (363 vs 332 minutes, P = .16). With a median follow-up of 24 months, radiological and clinical PSHs were detected in 37 (18 mesh recipients vs 19 controls) and 16 (8 subjects in both arms) patients, with a median time to radiological and clinical PSH of 8.3 and 15.5 months, respectively. No definite mesh-related adverse events were reported. Five patients (3 in the mesh and 2 in the control arm) required surgical PSH repair. Radiological PSH-free survival rates in the mesh and control groups were 74% vs 75% at 1 year and 69% vs 62% at 2 years. CONCLUSIONS: Implementation of biologic mesh at the time of IC construction is safe without significant protective effects within 2 years following surgery.


Asunto(s)
Cistectomía , Mallas Quirúrgicas , Derivación Urinaria , Humanos , Mallas Quirúrgicas/efectos adversos , Masculino , Femenino , Derivación Urinaria/métodos , Anciano , Persona de Mediana Edad , Cistectomía/métodos , Cistectomía/efectos adversos , Hernia Incisional/prevención & control , Neoplasias de la Vejiga Urinaria/cirugía , Estudios de Seguimiento , Complicaciones Posoperatorias/prevención & control , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Procedimientos Quirúrgicos Profilácticos/métodos
4.
BMJ Case Rep ; 17(4)2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38589247

RESUMEN

Corona mortis (CM) is an anastomotic vessel between the inferior epigastric or external iliac vessels and the obturator or internal iliac vessels. The Latin meaning of it is 'crown of death' which corresponds to massive haemorrhage caused by injury to this vessel during surgery. The incidence of this vessel is around 50% in the hemipelvis. We are presenting an intraoperative video of a right laparoscopic totally extraperitoneal mesh hernioplasty demonstrating a CM artery in the right hemipelvis. Care was taken to prevent injury to this vessel. CO2 insufflation pressure was reduced to less than 10 mm Hg to see any venous variant of this vessel. Carefully, polypropylene mesh was placed without a fixation device. Anatomical knowledge of the CM vessel is therefore essential in preventing injury for surgeons who approach the inguinal and retropubic regions.


Asunto(s)
Hernia Inguinal , Laparoscopía , Humanos , Arteria Ilíaca/cirugía , Herniorrafia , Mallas Quirúrgicas/efectos adversos , Arterias/cirugía , Hernia Inguinal/cirugía
5.
Chirurgia (Bucur) ; 119(1): 87-101, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38465719

RESUMEN

Background: Chronic postoperative inguinal pain (CPIP) is still the most frequent complication after open Lichtenstein repair and any strategy to reduce its incidence and implications is a step forward to better outcomes. Between the means of mesh fixation atraumatic glue fixation has been explored as such possibility. A meta-analysis of randomized controlled trials comparing the performance of cyanoacrylate glue versus sutures fixation was conducted. Methods: the meta-analysis was conducted according to the PRISMA guidelines. Randomized controlled trials (RCTs) published between January 2000 and December 2021 were searched for in MEDLINE, PubMed, Web of Science, and Google Scholars. The quality of RCTs and the potential risk of bias were assessed using MINORS criteria and the Cochrane risk of bias tool. Results: of 269 papers the meta-analysis was performed on 19 RCTs including 3578 patients. In the glue fixation group, the operation was shorter (mean pooled difference 6 minutes; SE = 0.47; 95% CI = - 6.77 - - 4.92; t test = -12.36; p 0.0001) and immediate postoperative pain was lower (2.37% vs 13.3%OR - 0.158; 95% CI = 0.064 0.386; p = 0.0001). There was no difference in terms of chronic pain, recurrence rate and wound events. Conclusion: glue fixation of mesh in elective Lichtenstein repair of inguinal hernia seems to be a valid choice for a painful and safe procedure without increasing risk of recurrence.


Asunto(s)
Dolor Crónico , Hernia Inguinal , Humanos , Cianoacrilatos/uso terapéutico , Mallas Quirúrgicas/efectos adversos , Resultado del Tratamiento , Ensayos Clínicos Controlados Aleatorios como Asunto , Dolor Postoperatorio/etiología , Dolor Postoperatorio/prevención & control , Dolor Crónico/etiología , Dolor Crónico/prevención & control , Suturas/efectos adversos , Hernia Inguinal/cirugía , Herniorrafia/métodos , Recurrencia
6.
Surg Endosc ; 38(4): 2231-2239, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38498213

RESUMEN

BACKGROUND: Biosynthetic meshes afford the cost advantages of being made from fully synthetic material, but are also biodegradable, making them a versatile option that can be used in both clean and contaminated cases. The aim of this study is to evaluate the safety profile and long-term outcomes of using GORE BIO-A (BIO-A) as an adjunct to abdominal wall reconstruction in all wound classes. METHODS: A retrospective review identified patients undergoing abdominal hernia repair using BIO-A from October 2008 to June 2018. The primary outcome was hernia recurrence rate. Only patients with at least 6-month follow-up were included when looking at recurrence rates. Secondary outcomes included 30-day morbidity categorized according to CDC Surgical Site Infection Criteria, return to operating/procedure room (RTOR), 30-day readmission, length of stay (LOS), and mortality. RESULTS: A total of 207 patients were identified, CDC Wound Classification breakdown was 127 (61.4%), 41 (19.8%), 14 (6.8%), and 25 (12.1%) for wound classes I, II, III, and IV, respectively. Median follow-up was 55.4 months (range 0.2-162.4). Overall recurrence rate was 17.4%. Contaminated cases experienced higher recurrence rates (28.8% versus 10.4%, p = 0.002) at a mean follow up of 46.9 and 60.8 months for contaminated and clean patients, respectively. Recurrent patients had higher BMI (32.4 versus 28.4 kg/m2, p = 0.0011), larger hernias (162.2 versus 106.7 cm2, p = 0.10), higher LOS (11.1 versus 5.6 days, p = 0.0051), and higher RTOR rates (16.7% versus 5.6%, p = 0.053). 51 (24.5%) patients experienced some morbidity, including 19 (9.2%) surgical site occurences, 7 (3.4%) superficial surgical site infections, 16 (7.7%) deep surgical site infections, and 1 (0.5%) organ space infection. CONCLUSION: This study affirms the use of biosynthetic mesh as a cost-effective alternative in all wound classifications, yielding good outcomes, limited long-term complications, and low recurrence. rates.


Asunto(s)
Hernia Ventral , Infección de la Herida Quirúrgica , Humanos , Infección de la Herida Quirúrgica/epidemiología , Infección de la Herida Quirúrgica/etiología , Infección de la Herida Quirúrgica/cirugía , Resultado del Tratamiento , Recurrencia Local de Neoplasia/cirugía , Hernia Ventral/cirugía , Hernia Ventral/complicaciones , Estudios Retrospectivos , Dehiscencia de la Herida Operatoria , Herniorrafia/métodos , Mallas Quirúrgicas/efectos adversos , Recurrencia
7.
Urogynecology (Phila) ; 30(3): 174-180, 2024 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-38484229

RESUMEN

IMPORTANCE: There are no current data investigating the relationship between mesh-exposure complications after midurethral sling surgery and antiestrogen therapy. OBJECTIVES: We sought to determine if there are increased mesh-exposure complications between a breast cancer population versus a noncancer population particularly in conjunction with hormone suppression (HS) therapy. STUDY DESIGN: A retrospective chart review was performed on patients with a history of breast cancer undergoing tension-free vaginal tape (TVT) surgery at our institution between 2013 and 2021. A group of patients who underwent TVT surgery without a history of cancer served as our control. Univariate and multivariate logistic regression analyses were performed to identify predictors of mesh exposure complications. RESULTS: One hundred twenty-one patients with breast cancer had TVT surgery. Two hundred ninety-seven patients without cancer had TVT surgery during the same period. Baseline characteristics across all groups were similar. Twenty-nine patients (6.9%) experienced mesh exposure. This occurred at a higher rate in our cancer (15.7%) versus the noncancer population (3.4%). Women with breast cancer taking HS therapy had a higher rate of mesh exposure complications compared with those not taking HS therapy (25.0% versus 6.6%; P = 0.005). The highest rate of mesh exposure complications occurred in the cohort taking estrogen receptor modulators, selective estrogen receptor modulator (10/36 [27.8%]) versus aromatase inhibitors (5/24 [20.8%]) versus no HS therapy (4/61 [6.6%]; P = 0.014). On multivariate analysis, HS therapy use (odds ratio, 1.57; P = 0.007) and diabetes mellitus (odds ratio, 4.53; P = 0.018) were associated with increased TVT-related complications. CONCLUSION: Women with breast cancer had a higher rate of mesh exposure complications from TVT surgery compared with women without cancer, particularly those taking antiestrogenic therapy.


Asunto(s)
Neoplasias de la Mama , Supervivientes de Cáncer , Cabestrillo Suburetral , Humanos , Femenino , Estudios Retrospectivos , Neoplasias de la Mama/tratamiento farmacológico , Mallas Quirúrgicas/efectos adversos , Cabestrillo Suburetral/efectos adversos , Moduladores de los Receptores de Estrógeno/efectos adversos
8.
Eur J Obstet Gynecol Reprod Biol ; 296: 275-279, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38493551

RESUMEN

OBJECTIVES: To report the results of a mesh-less laparoscopic extraperitoneal linear suspension technique for the treatment of post-hysterectomy vaginal vault prolapse (PHVP). STUDY DESIGN: A retrospective observational study was conducted collecting medical records of 41 patients with symptomatic PHVP treated between November 2017 to November 2019 in Gynecologic department of China-Japan Friendship Hospital. All patients had Pelvic Organ Prolapse Quantification (POP-Q) scores indicating stage 3-4 PHVP and underwent mesh-less laparoscopic extraperitoneal linear suspension.The primary outcome was the subjective satisfaction rate based on responses to validated questionnaires. The secondary outcomes were the objective anatomical cure rate based on POP-Q scores and complication rates. All listed parameters were determined before the surgery and at control examinations in 1 year and 3 years after the treatment. RESULTS: The operation was completed successfully without serious complications in all patients. Mean operation time was 53.8 mins. Comparison of the scores by the questionnaires revealed a significant improvement in the quality of life in the postoperative period.The subjective satisfaction rates were 100 % (41/41) and 95 % (38/40) at 1 year and 3 years after surgery. The objective cure rates were 100 % (41/41) and 97.5 % (39/40) at 1 year and 3 years after surgery, respectively. During the follow-up, none of the patients experienced suture exposure, infection, chronic pelvic pain, or other related complications. CONCLUSION: The mesh-less laparoscopic extraperitoneal linear suspension technique avoids the use of implantable synthetic mesh. It has been shown to lead to favorable postoperative outcomes, considerable patient contentment, and low complication rates. It offers a new, cost-effective treatment option for PHVP patients.


Asunto(s)
Laparoscopía , Prolapso de Órgano Pélvico , Humanos , Femenino , Procedimientos Quirúrgicos Ginecológicos/métodos , Mallas Quirúrgicas/efectos adversos , Calidad de Vida , Prolapso de Órgano Pélvico/cirugía , Resultado del Tratamiento , Laparoscopía/métodos
9.
Int Urogynecol J ; 35(3): 713-722, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38430238

RESUMEN

INTRODUCTION AND HYPOTHESIS: Fully absorbable implants may be an alternative to permanent meshes in the correction pf pelvic organ prolapse (POP) as they may reduce adverse events by promoting tissue regeneration and collagen metabolism. This study was aimed at evaluating the long-term host and biomechanical response to a fully absorbable poly-4-hydroxybutyrate (P4HB) scaffold in comparison with polypropylene (PP) mesh. METHODS: Poly-4-hydroxybutyrate scaffold (n = 16) and PP mesh (n = 16) were surgically implanted in the posterior vaginal wall of parous female Dohne Merino sheep. Vaginal explants were evaluated in terms of gross necropsy, host response (immune response, collagen deposition, tissue regeneration), biomechanics, and degradation of P4HB at 12 and 24 months post-implantation. RESULTS: Gross necropsy revealed no infection or fluid collection using P4HB or PP. At 12 months, exposures were observed with both P4HB (3 out of 8) and PP (4 out of 8), whereas at 24 months, exposures were observed only with PP (4 out of 8). The tensile stiffness of the P4HB explants was maintained over time despite complete absorption of P4HB. The collagen amount of the vaginal tissue after P4HB implantation increased over time and was significantly higher than PP at 24 months. P4HB scaffolds exhibited significantly lower myofibroblast differentiation than PP meshes at 24 months. CONCLUSIONS: The P4HB scaffold allowed for gradual load transfer to the vaginal wall and resulted in mechanically self-sufficient tissue. P4HB scaffold had a more favorable host response than PP mesh, with higher collagen content, lower myofibroblastic differentiation, and no exposures at 24 months. P4HB scaffolds have potential as an alternative to permanent implants in treating POP.


Asunto(s)
Prolapso de Órgano Pélvico , Femenino , Humanos , Prolapso de Órgano Pélvico/cirugía , Prolapso de Órgano Pélvico/metabolismo , Vagina/cirugía , Vagina/metabolismo , Colágeno/metabolismo , Implantes Absorbibles , Cicatrización de Heridas , Mallas Quirúrgicas/efectos adversos
10.
Int Urogynecol J ; 35(4): 901-907, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38530401

RESUMEN

INTRODUCTION AND HYPOTHESIS: The objective was to assess long-term mesh complications following total hysterectomy and sacrocolpopexy. METHODS: In this second extension study, women from a multicenter randomized trial were followed for more than 36 months after surgery. Owing to COVID-19, participants were assessed through either in-person visits or telephone questionnaires. The primary outcome was the incidence of permanent suture or mesh exposure. Secondary outcomes included surgical success and late adverse outcomes. RESULTS: Out of the 200 initially enrolled participants, 82 women took part in this second extension study. Among them, 46 were in the permanent suture group, and 36 in the delayed absorbable group. The mean follow-up duration was 5.3 years, with the cumulative mesh or suture exposure of 9.9%, involving 18 cases, of which 4 were incident cases. Surgical success after more than 5 years stood at 95%, with few experiencing bothersome bulge symptoms or requiring retreatment. No serious adverse events occurred, including mesh erosion into the bladder or bowel. The most common adverse events were vaginal pain, bleeding, dyspareunia, and stress urinary incontinence, with no significant differences between suture types. CONCLUSION: The study found that mesh exposure risk gradually increased over time, reaching nearly 10% after more than 5 years post-surgery, regardless of suture type. However, surgical success remained high, and no delayed serious adverse events were reported.


Asunto(s)
Histerectomía , Prolapso de Órgano Pélvico , Complicaciones Posoperatorias , Mallas Quirúrgicas , Humanos , Femenino , Mallas Quirúrgicas/efectos adversos , Persona de Mediana Edad , Histerectomía/efectos adversos , Anciano , Prolapso de Órgano Pélvico/cirugía , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/epidemiología , Factores de Tiempo , Estudios de Seguimiento , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Procedimientos Quirúrgicos Ginecológicos/efectos adversos , Procedimientos Quirúrgicos Ginecológicos/métodos , Suturas/efectos adversos
11.
Colorectal Dis ; 26(4): 609-621, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38459408

RESUMEN

AIM: The development of robotic assistance has made dissection and suturing in the deep pelvis much easier. The augmented quality of the images and the articulation of the robotic arms have also enabled a more precise dissection. The aim of this study is to present the data on robotic-assisted ventral mesh rectopexy procedures in a university hospital and examine the literature in terms of mesh erosion. METHOD: The electronic databases Pubmed, Embase and Cochrane were searched. Studies from January 2004 until January 2023 in the English language were included. Studies which included fewer than 10 patients were excluded. Laparoscopic or robotic-assisted ventral mesh rectopexies were included. Mesh erosion rates following laparoscopic or robotic-assisted ventral mesh rectopexies were measured. RESULTS: Overall, the systematic review presents 5911 patients from 43 studies who underwent laparoscopic ventral mesh rectopexy compared with 746 patients treated with robotic-assisted ventral mesh rectopexy from six studies and our centre. Mesh erosion was rare in both groups; however, the prevalence was greater in the laparoscopy group (0.90% vs. 0.27%). CONCLUSION: The mesh erosion rates are very low with robotic-assisted ventral mesh rectopexy. For precise results, more studies and experience in robotic surgery are required.


Asunto(s)
Laparoscopía , Complicaciones Posoperatorias , Prolapso Rectal , Procedimientos Quirúrgicos Robotizados , Mallas Quirúrgicas , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Laparoscopía/métodos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/prevención & control , Prolapso Rectal/cirugía , Recto/cirugía , Procedimientos Quirúrgicos Robotizados/métodos , Mallas Quirúrgicas/efectos adversos , Centros de Atención Terciaria
12.
Medicina (Kaunas) ; 60(2)2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38399573

RESUMEN

Background: Prospective single and multicenter studies have shown improved outcomes of patients who underwent carotid artery stenting with the novel CGuard dual-layer mesh stent at 1 year. Objectives: The aim of this study is to conduct a systematic review and meta-analysis of all published studies to assess 1-year efficacy and outcomes of CGuard in patients with carotid stenting. Methods: A systematic search was performed. All studies enrolling at least 20 patients were included in our analysis. The primary endpoints were death (all-cause, cardiovascular and ipsilateral stroke-related death) and stroke rate at 1 year. The secondary endpoint was in-stent restenosis at 1 year. Results: The final analysis included 1709 patients. The one-year all-cause mortality rate was 2.97% (39/1699, 95% CI: 1.26-6.86%, I2 = 67%, t2 = 0.3442, p < 0.01), cardiovascular-related death was 0.92% (10/1616, 95% CI: 0.35-2.39%, I2 = 34%, t2 = 0.2302, p = 0.18), and ipsilateral stroke-related death was 0.3% (1/1649, 95% CI: 0.1-0.87%, I2 = 0%, t2 = 0, p = 0.69). The one-year ipsilateral stroke rate was 1.21% (16/1649, 95% CI: 0.58-2.5%, I2 = 28%, t2 = 0.1433, p = 0.23), transient ischemic attacks (TIAs) rate was 1.78% (19/1149, 95% CI: 1.11-2.84%, I2 = 0%, t2 = 0, p = 0.69), and total composite 1-year stroke/TIA rate was 2.97% (32/1149, 95% CI: 1.84-4.77%, I2 = 0%, t2 = 0, p = 0.41). The in-stent restenosis rate at 1 year was 1.06% (13/1653, 95% CI: 0.48-2.34%, I2 = 28%, t2 = 0.2308, p = 0.22). Conclusions: This meta-analysis shows that CAS with CGuard is safe with minimal neurological adverse events and in-stent restenosis rate at 1 year.


Asunto(s)
Enfermedades de las Arterias Carótidas , Estenosis Carotídea , Reestenosis Coronaria , Accidente Cerebrovascular , Humanos , Estenosis Carotídea/complicaciones , Estenosis Carotídea/cirugía , Stents/efectos adversos , Estudios Prospectivos , Mallas Quirúrgicas/efectos adversos , Reestenosis Coronaria/complicaciones , Resultado del Tratamiento , Enfermedades de las Arterias Carótidas/complicaciones , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/complicaciones , Constricción Patológica , Factores de Riesgo
14.
Medicine (Baltimore) ; 103(8): e37223, 2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38394531

RESUMEN

INTRODUCTION: Perineal hernia (PH) is a rare complication that can occur after abdominoperineal resection for rectal cancer. Laparoscopic repair of PHs has gained increasing popularity compared to open approaches due to advantages such as superior visualization, decreased invasiveness, and faster recovery. This case report highlights the successful use of laparoscopic tension-free mesh repair for concurrent perineal and inguinal hernias after rectal cancer surgery. CASE DESCRIPTION: A 51-year-old man underwent laparoscopic-assisted abdominoperineal resection for rectal cancer. About 2 months postoperatively, he developed reducible masses in the perineal and left groin regions, associated with urinary symptoms and sensation of prolapse. Physical exam revealed protruding masses that enlarged with Valsalva. Pelvic CT confirmed PH and left inguinal hernia. INTERVENTIONS: Laparoscopic tension-free repair of the PH and inguinal hernia was performed on this patient. The repair was completed by the steps of adhesion separation, mesh placement, and fixation. OUTCOMES: The 98-minute surgery was successful without complications. The patient recovered well, ambulating on postoperative day 2 and getting discharged on day 6. CONCLUSION: This case demonstrates that laparoscopic tension-free repair with mesh is an effective approach for treating PH and concurrent inguinal hernia following rectal cancer surgery, resulting in successful outcomes and low recurrence rates. The laparoscopic technique provides benefits of minimal invasiveness and rapid recovery.


Asunto(s)
Hernia Abdominal , Hernia Inguinal , Laparoscopía , Neoplasias del Recto , Masculino , Humanos , Persona de Mediana Edad , Hernia Inguinal/cirugía , Hernia Abdominal/cirugía , Recto/cirugía , Neoplasias del Recto/cirugía , Laparoscopía/efectos adversos , Herniorrafia/métodos , Mallas Quirúrgicas/efectos adversos
16.
Biomater Adv ; 159: 213800, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38377947

RESUMEN

Currently, in vitro testing examines the cytotoxicity of biomaterials but fails to consider how materials respond to mechanical forces and the immune response to them; both are crucial for successful long-term implantation. A notable example of this failure is polypropylene mid-urethral mesh used in the treatment of stress urinary incontinence (SUI). The mesh was largely successful in abdominal hernia repair but produced significant complications when repurposed to treat SUI. Developing more physiologically relevant in vitro test models would allow more physiologically relevant data to be collected about how biomaterials will interact with the body. This study investigates the effects of mechanochemical distress (a combination of oxidation and mechanical distention) on polypropylene mesh surfaces and the effect this has on macrophage gene expression. Surface topology of the mesh was characterised using SEM and AFM; ATR-FTIR, EDX and Raman spectroscopy was applied to detect surface oxidation and structural molecular alterations. Uniaxial mechanical testing was performed to reveal any bulk mechanical changes. RT-qPCR of selected pro-fibrotic and pro-inflammatory genes was carried out on macrophages cultured on control and mechanochemically distressed PP mesh. Following exposure to mechanochemical distress the mesh surface was observed to crack and craze and helical defects were detected in the polymer backbone. Surface oxidation of the mesh was seen after macrophage attachment for 7 days. These changes in mesh surface triggered modified gene expression in macrophages. Pro-fibrotic and pro-inflammatory genes were upregulated after macrophages were cultured on mechanochemically distressed mesh, whereas the same genes were down-regulated in macrophages exposed to control mesh. This study highlights the relationship between macrophages and polypropylene surgical mesh, thus offering more insight into the fate of an implanted material than existing in vitro testing.


Asunto(s)
Mallas Quirúrgicas , Incontinencia Urinaria de Esfuerzo , Humanos , Ensayo de Materiales , Mallas Quirúrgicas/efectos adversos , Polipropilenos/química , Materiales Biocompatibles , Macrófagos , Incontinencia Urinaria de Esfuerzo/cirugía
17.
J Craniomaxillofac Surg ; 52(4): 532-537, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38368208

RESUMEN

This study aimed to compare the accuracy of inferomedial orbital fracture restoration using customized orbital implant versus 3D preformed titanium mesh. Patients were divided into two groups. Group 1 underwent surgery with customized orbital implants and intraoperative navigation, while group 2 was treated using 3D preformed titanium meshes with preoperative virtual surgical planning (VSP) and intraoperative navigation. Reconstruction accuracy was assessed by: (1) comparing the postoperative reconstruction mesh position with the preoperative VSP; and (2) measuring the difference between the reconstructed and unaffected orbital volume. Pre- and postoperative diplopia and enophthalmos were also evaluated. Fifty-two patients were enrolled (25 in group 1 vs 27 in group 2). The mean difference between final plate position and ideal digital plan was 0.62 mm (SD = 0.235) in group 1 and 0.69 mm (SD = 0.246) in group 2, with no statistical difference between the groups (p = 0.282). The mean volume differences between the reconstructed and unaffected orbits were 0.95 ml and 1.02 ml in group 1 and group 2, respectively, with no significant difference between the groups (p = 0.860). Overall clinical improvements, as well as complications, were similar. 3D preformed titanium meshes can reconstruct inferomedial fractures with the same accuracy as customized implants. Therefore, in clinical practice, it is recommended to use 3D preformed meshes for this type of fracture due to their excellent results and the potential for reducing time and costs.


Asunto(s)
Implantes Dentales , Enoftalmia , Fracturas Orbitales , Implantes Orbitales , Humanos , Fracturas Orbitales/diagnóstico por imagen , Fracturas Orbitales/cirugía , Fracturas Orbitales/complicaciones , Implantes Orbitales/efectos adversos , Titanio , Estudios Retrospectivos , Mallas Quirúrgicas/efectos adversos , Órbita/cirugía , Enoftalmia/etiología , Enoftalmia/cirugía
18.
Int Urogynecol J ; 35(4): 921-923, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38308690

RESUMEN

INTRODUCTION AND HYPOTHESIS: Intravesical mesh is an uncommon complication following synthetic midurethral sling placement. Management options have included endoscopic techniques such as laser ablation or surgical excision. We present our technique for robotic-assisted excision of intravesical mesh following a retropubic midurethral sling. METHODS: The patient is a 66-year-old woman with a remote history of laser ablation of intraurethral mesh after midurethral sling, and persistent symptomatic intravesical mesh with associated stone at the bladder neck and right bladder wall. Robotic excision of the intravesical mesh and stone was performed by entering the space of Retzius, carrying the dissection along the right arm of the retropubic sling, performing two cystotomies to free and remove the mesh, and finally closing the cystotomies in two layers. RESULTS: The patient was discharged on postoperative day 1. A cystogram prior to catheter removal showed no extravasation and a competent bladder neck. She reported no new stress incontinence and had improvement in overactive bladder symptoms. CONCLUSIONS: Robotic excision of intravesical mesh after synthetic midurethral sling was safely performed in this patient who had multiple areas of intravesical mesh. Management aspects reported here may be helpful for complex presentations of intravesical mesh.


Asunto(s)
Procedimientos Quirúrgicos Robotizados , Cabestrillo Suburetral , Mallas Quirúrgicas , Anciano , Femenino , Humanos , Remoción de Dispositivos/métodos , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía , Procedimientos Quirúrgicos Robotizados/métodos , Cabestrillo Suburetral/efectos adversos , Mallas Quirúrgicas/efectos adversos , Vejiga Urinaria/cirugía , Cálculos de la Vejiga Urinaria/cirugía , Cálculos de la Vejiga Urinaria/etiología , Incontinencia Urinaria de Esfuerzo/cirugía
19.
Hernia ; 28(2): 385-400, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38319440

RESUMEN

PURPOSE: Despite advancements in laparoscopic ventral hernia repair (LVHR) using the intraperitoneal onlay mesh technique (sIPOM), recurrence remains a common postoperative complication. The objective of this systematic review and meta-analysis is to compare the efficacy of defect closure (IPOM-plus) versus non-closure in ventral and incisional hernia repair. The aim is to determine which technique yields better outcomes in terms of reducing recurrence and complication rates. METHODS: A comprehensive literature review was conducted in the PubMed, Web of Science, Cochrane Library, Embase, and ClinicalTrials.gov databases from their inception until October 1, 2022, to identify all online English publications that compared the outcomes of laparoscopic ventral hernia repair with and without fascia closure. RESULTS: Three randomized controlled trials (RCTs) and eleven cohort studies involving 1585 patients met the inclusion criteria. The IPOM-plus technique was found to reduce the recurrence of hernias (OR = 0.51, 95% CI [0.35, 0.76], p < 0.01), seroma (OR = 0.48, 95% CI [0.32, 0.71], p < 0.01), and mesh bulging (OR = 0.08, 95% CI [0.01, 0.42], p < 0.01). Subgroup analysis revealed that body mass index (BMI) (OR = 0.43, 95% CI [0.29, 0.65], p < 0.0001), type of article (OR = 0.51, 95% CI [0.35, 0.76], p = 0.0008 < 0.01), geographical location (OR = 0.54, 95% CI [0.36, 0.82], p = 0.004 < 0.01), follow-up time (OR = 0.50, 95% CI [0.34, 0.73], p = 0.0004 < 0.01) had a significant influence on the postoperative recurrence of the IPOM-plus technique. CONCLUSION: The IPOM-plus technique has been shown to greatly reduce the occurrence of recurrence, seroma, and mesh bulging. Overall, the IPOM-plus technique is considered a safe and effective procedure. However, additional randomized controlled studies with extended follow-up periods are necessary to further evaluate the IPOM-plus technique.


Asunto(s)
Hernia Ventral , Hernia Incisional , Laparoscopía , Humanos , Fascia , Hernia Ventral/cirugía , Herniorrafia/efectos adversos , Herniorrafia/métodos , Hernia Incisional/cirugía , Laparoscopía/efectos adversos , Laparoscopía/métodos , Recurrencia , Seroma/etiología , Seroma/epidemiología , Mallas Quirúrgicas/efectos adversos
20.
Hernia ; 28(2): 575-584, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38345668

RESUMEN

PURPOSE: Use of biologic or synthetic mesh in hernia repair shifts is based on evolving evidence. Poly-4-hydroxybutyrate (P4HB) biosynthetic mesh is a potential alternative to biologic and synthetic mesh in ventral hernia repair (VHR). This meta-analysis assesses the efficacy of P4HB mesh in clean and contaminated surgical settings. METHODS: Two authors searched literature on PubMed, reviewing titles and abstracts of all articles to determine inclusion eligibility. Post-operative data were compared via transformation method to convert the proportion of patients with the outcome of interest into a suitable quantity for random-effects synthesis using STATA software. RESULTS: Initial search yielded 287 citations. Six studies were included and categorized on whether hernia repairs were conducted in clean (CDC class I) or contaminated cases (CDC class II-IV). The pooled proportion of surgical site infection (SSI), surgical site occurrence (SSO), hernia recurrence, total surgical complications, and reoperation were calculated in 391 clean and 81 contaminated cases. For clean vs. contaminated cases, the following pooled proportions were noted: SSI (2% (CI 0-7%) vs 9% (CI 0-025) (p = 0.03), SSO: 14% (CI 5-25%) vs 35% (CI 22-50%) (p = 0.006), hernia recurrence (8% (CI 1-19%) vs 4% (CI 0-12%) (p = 0.769); surgical complications (17% (CI 6-32%) vs 50% (CI 27-72%) (p = 0.009). Reoperation data were available in 298 clean cases across four studies: 5% (CI 0-15%). CONCLUSIONS: P4HB biosynthetic mesh may be more effective than previously thought, particularly in clean wounds. P4HB may also be superior to biologic mesh when compared to clinical trial data. Further research is necessary for more direct comparison.


Asunto(s)
Productos Biológicos , Hernia Ventral , Humanos , Herniorrafia/efectos adversos , Herniorrafia/métodos , Resultado del Tratamiento , Mallas Quirúrgicas/efectos adversos , Implantes Absorbibles , Infección de la Herida Quirúrgica/cirugía , Hernia Ventral/cirugía , Hernia Ventral/complicaciones , Hidroxibutiratos , Recurrencia , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...