Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 303
Filtrar
1.
Anat Sci Int ; 99(3): 278-289, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38698275

RESUMEN

The shoulder joint has a high degree of freedom and an extremely complex and unstable kinematic mechanism. Coordinated contraction of the rotator cuff muscles that stop around the humeral head and the deltoid muscles and the extensibility of soft tissues, such as the joint capsule, labrum, and ligaments, contribute to shoulder-joint stability. Understanding the mechanics of shoulder-joint movement, including soft-tissue characteristics, is important for disease prevention and the development of a device for disease treatment. This study aimed to create a musculoskeletal shoulder model to represent the realistic behavior of joint movement and soft-tissue deformation as a dynamic simulation using a rigid-body model for bones and a soft-body model for soft tissues via a spring-damper-mass system. To reproduce the muscle-contraction properties of organisms, we used a muscle-expansion representation and Hill's mechanical muscle model. Shoulder motion, including the movement of the center of rotation in joints, was reproduced, and the strain in the joint capsule during dynamic shoulder movement was quantified. Furthermore, we investigated narrowing of the acromiohumeral distance in several situations to induce tissue damage due to rotator cuff impingement at the anterior-subacromial border during shoulder abduction. Given that the model can analyze exercises under disease conditions, such as muscle and tendon injuries and impingement syndrome, the proposed model is expected to help elucidate disease mechanisms and develop treatment guidelines.


Asunto(s)
Modelos Anatómicos , Articulación del Hombro , Articulación del Hombro/anatomía & histología , Articulación del Hombro/fisiología , Humanos , Fenómenos Biomecánicos , Rango del Movimiento Articular , Manguito de los Rotadores/fisiología , Manguito de los Rotadores/anatomía & histología , Músculo Esquelético/anatomía & histología , Músculo Esquelético/fisiología , Simulación por Computador
2.
Anat Sci Int ; 99(3): 290-304, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38717695

RESUMEN

This study aimed to describe the shoulder anatomy, together with the anatomical relationships in adults and early stages of development. The shoulder muscles were studied from ultrasound, anatomical, and microscopic perspectives in a sample of 34 human shoulders. Thickness measurements were taken of the tendons and fasciae of the subscapularis, long head tendon of the biceps brachii, supraspinatus, infraspinatus, and teres minor. Ultrasound and dissection techniques are strongly correlated. However, the measurements obtained from the dissection technique were superior to those obtained from the ultrasound in all cases, except for the thickness of the long head tendon of the biceps brachii, the teres minor tendon, and the fascia thickness of the infraspinatus. In addition, the study of shoulder anatomy revealed no differences between females and males. Relevant findings from dissection included a clear overlap between the infraspinatus and supraspinatus, which shared tendon fibers, and a similar connection between the transverse ligament of the long head tendon of the biceps brachii and the subscapularis, which created a more interconnected shoulder function. The study of the anatomical measurements shows an underestimation of the shoulder measurements in the ultrasound compared with the dissection technique, but a high correlation between the measurements made by the two techniques. We present reference values for the tendon and fascia thicknesses of the rotator cuff, with no differences observed by gender. The relationships between shoulder structures described in the anatomical study imply as well that, in the event of an injury, adjacent tissues may be affected. This extended information may facilitate future optimal clinical explorations.


Asunto(s)
Hombro , Tendones , Ultrasonografía , Humanos , Ultrasonografía/métodos , Masculino , Femenino , Hombro/anatomía & histología , Hombro/diagnóstico por imagen , Tendones/anatomía & histología , Tendones/diagnóstico por imagen , Manguito de los Rotadores/diagnóstico por imagen , Manguito de los Rotadores/anatomía & histología , Músculo Esquelético/anatomía & histología , Músculo Esquelético/diagnóstico por imagen , Adulto , Disección , Articulación del Hombro/anatomía & histología , Articulación del Hombro/diagnóstico por imagen , Persona de Mediana Edad , Anciano
3.
Comput Biol Med ; 174: 108401, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38603897

RESUMEN

Incorporating detailed muscle architecture aspects into computational models can enable researchers to gain deeper insights into the complexity of muscle function, movement, and performance. In this study, we employed histological, multiphoton image processing, and finite element method techniques to characterise the mechanical dependency on the architectural behaviour of supraspinatus and infraspinatus mouse muscles. While mechanical tests revealed a stiffer passive behaviour in the supraspinatus muscle, the collagen content was found to be two times higher in the infraspinatus. This effect was unveiled by analysing the alignment of fibres during muscle stretch with the 3D models and the parameters obtained in the fitting. Therefore, a strong dependence of muscle behaviour, both active and passive, was found on fibre orientation rather than collagen content.


Asunto(s)
Manguito de los Rotadores , Animales , Ratones , Manguito de los Rotadores/fisiología , Manguito de los Rotadores/anatomía & histología , Análisis de Elementos Finitos , Fenómenos Biomecánicos/fisiología , Modelos Biológicos , Colágeno/química , Colágeno/metabolismo , Masculino , Ratones Endogámicos C57BL
4.
Surg Radiol Anat ; 45(12): 1579-1586, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37773544

RESUMEN

PURPOSE: This study aimed to evaluate the morphology of the three parts of the infraspinatus muscle based on surface landmarks for precise and effective access, and to propose the most effective fine-wire electrode insertion technique and sites. METHODS: Fifteen Asian fresh cadavers were used. We investigated the probability of the presence of the superior, middle, and inferior parts in each infraspinatus muscle based on surface landmarks. Based on the positional characteristics of the muscle, we determined the needle insertion method and confirmed its effectiveness by dissection. RESULTS: The superior part was mostly observed near the spine of the scapula. The middle part was broadly observed within the infraspinous fossa. The inferior part showed variable location within the infraspinous fossa. The injection accuracy of the superior, middle, and inferior parts in the infraspinatus muscle was 95.8%, 100%, and 91.7%, respectively. Targeting the superior and middle parts for injection of the infraspinatus muscle is relatively more straightforward than targeting the inferior part. Targeting the inferior part of the infraspinatus muscle in this study was more challenging than targeting the superior and middle parts. CONCLUSION: Needling for electromyography should be performed with special care to avoid unintended muscle parts, which could lead to inaccurate data acquisition and affect the conclusions about muscle function.


Asunto(s)
Manguito de los Rotadores , Escápula , Humanos , Manguito de los Rotadores/anatomía & histología , Disección , Cadáver , Agujas
5.
Surg Radiol Anat ; 44(9): 1305-1308, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35962136

RESUMEN

The infraspinatus muscle is situated under the scapular spine in the infraspinous fossa and inserts into the greater tuberosity of the humerus. It is a component of a crucial shoulder muscle group, the rotator cuff. There are a few interesting additional muscles in the infraspinal region. In the literature they are called the infraspinatus superficialis, infraspinatus minor and infraspinatus accessory muscles. The infraspinatus minor muscle is described as a superficial muscle bundle running under the scapular spine. During routine anatomical dissection, an unreported variation of the infraspinatus minor muscle was found. It derived from the inferior surface of the scapular spine and the infraspinous fossa. It had two heads. The superior head inserted on the greater tuberosity of the humerus. The inferior head inserted on the tendinous part of the infraspinatus muscle. There was also an unusual fusion of the infraspinatus muscle with the teres minor muscle. In this paper we will discuss the anatomical and physiological relationships of this morphological variation.


Asunto(s)
Lesiones del Manguito de los Rotadores , Articulación del Hombro , Humanos , Manguito de los Rotadores/anatomía & histología , Escápula/anatomía & histología , Articulación del Hombro/anatomía & histología , Tendones/anatomía & histología
7.
Arch Orthop Trauma Surg ; 141(7): 1231-1239, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33454805

RESUMEN

INTRODUCTION: The "Comma sign" is a well-known indicator of the subscapularis torn edge of the shoulder. We undertook a histoanatomical study of the fiber bundle forming Comma sign (FBCS) to determine why FBCS is maintained even in cuff tear cases. MATERIALS AND METHODS: Part 1: five tissue blocks including the supraspinatus tendon (SSP), rotator interval (RI), and subscapularis tendon (SSC) out of 5 cuff-intact cadavers were histologically observed in serial sections. Part 2: another tissue blocks of 6 cuff-intact cadavers were serially sectioned along the estimated FBCS direction based on the Part 1 findings. Additionally, 5 tissue blocks of cuff-torn cadavers including the three components, SSP, FBCS, and SSC, were serially sectioned along the apparent FBCS. In one slice clearly demonstrating FBCS fibers out of each section series, the components were measured of the sound speed and visualized through a scanning acoustic microscope (SAM). RESULTS: At the lateral portion, RI tissue with the joint capsule became thick and tightly surrounded SSP. Similarly, thicker RI tissue adhered to SSC from the superior and bursal side. More laterally, the borders of SSP/FBCS and FBCS/SSC were unclear with intermingled fibers. At the lateral most portion, RI tissue formed a fiber bundle, FBCS, extending from SSP to the bursal side of SSC. The sound speeds of SSP and SSC were significantly faster than FBCS in both cuff-intact and cuff-torn slices. In SAM images of cuff-torn specimens the FBCS borders were all unclear. CONCLUSIONS: As FBCS extends from the capsule beneath SSP and to the bursal surface of SSC, the FBCS connection to SSP and SSC is hardly lost, even though SSP or SSC detaches from the greater or lesser tubercle, respectively. Additionally, as degeneration make the elasticity difference gradual, the stress concentration at the borders may be diminished, leading to less breakage of FBCS.


Asunto(s)
Lesiones del Manguito de los Rotadores/patología , Manguito de los Rotadores , Histocitoquímica , Humanos , Manguito de los Rotadores/anatomía & histología , Manguito de los Rotadores/patología
8.
Surg Radiol Anat ; 43(1): 19-25, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32656573

RESUMEN

The subscapularis muscle is the largest muscle of the rotator cuff and its main function is internal rotation. It is morphologically variable in both point of origin and insertion. The presence of an accessory subscapularis muscle can lead to brachial plexus neuropathy. This report presents a very rare accessory subscapularis muscle originating from two distinct bands on the subscapularis and teres major muscles. The insertion was divided among four tendons. The fourth tendon is bifurcated. One of these was connected to the tendon of the subscapularis muscle and the other three inserted into the base of the coracoid process of the scapula. This anomalous muscle has the potential to entrap the nerves of the posterior cord such as the axillary, lower subscapular, and thoracodorsal nerves.


Asunto(s)
Manguito de los Rotadores/anatomía & histología , Variación Anatómica , Femenino , Humanos , Persona de Mediana Edad
9.
Phys Ther Sport ; 47: 173-177, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33310584

RESUMEN

OBJECTIVES: To compare the change in supraspinatus tendon thickness (STT) following a high volume (HV) and high intensity (HI) swimming practice in shoulders of elite swimmers. DESIGN: Cohort Study. SETTING: Non-clinical, state swim team training facility. PARTICIPANTS: A convenience sample of eight non-injured state and national level swimmers from a regional swim team were recruited for this study. MAIN OUTCOME MEASURES: Ultrasound measures of STT were collected in response to the two swimming practice sessions. Measures were taken prior to each swim practice; immediately after practice; 6-hours post practice and 24-hours post practice. RESULTS: A significant increase in STT resulted from both the HI and HV (p < 0.05) practice immediately post practice. For the HI practice, the STT remained significantly thicker than pre-practice measures at the 6-hour post practice test (p < 0.05) however no longer significant 24-hours post practice. The difference in the change in STT between the HI and HV practice was significantly different immediately post practice and 6-hours post practice (p < 0.05) however no longer significant 24-hour post practice. CONCLUSION: Ultrasound measures of STT following different swimming volumes and intensities may provide information on shoulder tendon loads.


Asunto(s)
Acondicionamiento Físico Humano/fisiología , Manguito de los Rotadores/anatomía & histología , Natación/fisiología , Adolescente , Estudios de Cohortes , Femenino , Humanos , Masculino , Manguito de los Rotadores/diagnóstico por imagen , Hombro/diagnóstico por imagen , Dolor de Hombro/fisiopatología , Ultrasonografía
10.
Ann Biomed Eng ; 49(5): 1333-1341, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33145676

RESUMEN

Cigarette smoking is the largest cause of preventable deaths, and a known risk factor for musculoskeletal issues including rotator cuff tendon tears. Tendon degeneration is believed to be due in part to changes in tendon cell health and collagen structure. Several studies have demonstrated that exposure to nicotine negatively impacts tendon healing, but surprisingly, nicotine exposure was shown to increase rat supraspinatus tendon stiffness. In order to address this seeming contradiction, the objective of this study was to comprehensively investigate the effects of long-term (18 weeks) exposure of nicotine on tendon-to-bone microstructural properties in a rat model. We hypothesized that long term subcutaneous nicotine delivery would lead to diminished tendon mechanical properties, decreased bone microstructure in the humeral head, and altered tendon cell morphology compared to age-matched control rats receiving saline. Results demonstrated a small decrease in tendon size and stiffness, with decreased cell density in the tendon midsubstance. However, no differences were found in the enthesis fibrocartilage or in the underlying subchondral or trabecular bone. In conclusion, our study revealed limited effects of nicotine on the homeostatic condition of the supraspinatus tendon, enthesis, and underlying bone. Future studies are needed to ascertain effects of other components of tobacco products.


Asunto(s)
Húmero/efectos de los fármacos , Nicotina/toxicidad , Manguito de los Rotadores/efectos de los fármacos , Animales , Húmero/anatomía & histología , Húmero/diagnóstico por imagen , Húmero/fisiología , Masculino , Ratas Sprague-Dawley , Manguito de los Rotadores/anatomía & histología , Manguito de los Rotadores/diagnóstico por imagen , Microtomografía por Rayos X
11.
Eur. j. anat ; 24(6): 459-465, nov. 2020. tab, ilus
Artículo en Inglés | IBECS | ID: ibc-198386

RESUMEN

Advanced cases of subacromial impingement syndrome usually present with acromial spurs. However, previous studies have reported variations in the prevalence of acromial spurs in shoulders with or without subacromial impingement syndrome as well as with age, sex, and side. Therefore, this study is aimed at investigating the prevalence of acromial spurs in cadaveric shoulders and reviewing the factors leading to the reported variable frequencies. The study examined 220 cadaveric shoulders (110 male and 110 female), with a median age of 82 years (with a range of 53 to 102 years). In 155 shoulders, the rotator cuff tendons were evaluated for tears; acromial spurs were observed in 95 shoulders (43%). No significant association was observed between the prevalence of acromial spurs and sex or side. However, a significant prevalence of spurs (57%) was observed in the oldest-old group, aged ≥ 85 years. Those with acromial spurs also tended to be older (84 years) than those without spurs (81 years). A significant difference in the prevalence of acromial spurs was observed in shoulders with rotator cuff tears compared to those without them: 80% compared to 20%, respectively. Analysis showed a significant number of acromial spurs in shoulders with full-thickness tears (46%) and partial tears (34%). A significant prevalence of acromial spurs was found in shoulders with rotator cuff tears, as well as in aged shoulders. In relevant literature, the prevalence of acromial spurs varies with the type of study undertaken, age, prevalence of rotator cuff tears, and type of radiograph examined


No disponible


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Acromion/anatomía & histología , Estudios de Cohortes , Hombro/anatomía & histología , Manguito de los Rotadores/anatomía & histología , Cadáver , Acromion/patología , Estudios Prospectivos , Disección/métodos , Lesiones del Hombro/patología , Dolor de Hombro
12.
Am J Sports Med ; 48(8): 1837-1845, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32441993

RESUMEN

BACKGROUND: While several studies have qualitatively described the anatomy of the glenohumeral ligaments, there remains a lack of consensus regarding their quantitative humeral and glenoid attachment sites. PURPOSE: To quantitatively and qualitatively describe the anatomic humeral and glenoid attachment sites of the glenohumeral ligaments and their relationship to well-established anatomic landmarks. STUDY DESIGN: Descriptive laboratory study. METHODS: A total of 10 nonpaired, fresh-frozen human cadaveric shoulders were included in this study. A 3-dimensional coordinate measuring device was used to quantify the location of pertinent bony landmarks and soft tissue attachment areas. All subcutaneous tissues and musculature were removed, with the exception of the rotator cuff (respective muscle bellies cut at their musculotendinous junctions) and the long head of the biceps tendon. The superior glenohumeral ligament (SGHL), middle glenohumeral ligament (MGHL), anteroinferior glenohumeral ligament (AIGHL), posteroinferior glenohumeral ligament (PIGHL), and coracohumeral ligament (CHL) were then transected. Coordinates of points along the perimeters of attachment sites were used to calculate areas, while coordinates of center points were used to determine distances between surgically relevant attachment sites and pertinent bony landmarks. RESULTS: The mean length of the SGHL humeral attachment along the intra-articular cartilage margin was 9.5 ± 3.2 mm, spanning from 12:55 to 1:40, while the SGHL glenoid attachment to the labrum was 1.9 ± 1.2 mm medial to the most lateral extent of the labral rim, spanning from 12:30 to 12:45. The mean length of the MGHL attachment along the intra-articular cartilage margin was 16.4 ± 3.0 mm, equating to 2:10 to 3:35 on the humeral head clockface, and the glenoid attachment was confluent with the labrum, attaching 1.5 ± 1.0 mm medial to the most lateral extent of the labral rim and thus extending from 1:50 to 2:35 on the glenoid clockface. The mean length of the AIGHL attachment along the intra-articular cartilage margin was 12.0 ± 3.0 mm, spanning from 4:05 to 5:10 on the humeral head clockface. The AIGHL bony footprint on the glenoid neck was 48.4 ± 24.5 mm2. The confluent attachment of the AIGHL to the labrum was 1.2 ± 0.9 mm medial to the most lateral extent of the labral rim, corresponding to 3:30 to 4:05 on the glenoid clockface. The mean length of the PIGHL attachment along the intra-articular cartilage margin was 12.0 ± 1.4 mm, spanning from 7:40 to 8:50 on the humeral head clockface. The PIGHL attachment to the labrum was 1.2 ± 0.5 mm medial to the most lateral extent of the labral rim. This attachment to the labrum was calculated to span from 7:35 to 8:50 on the glenoid clockface. The mean length of the CHL origin from the coracoid was 12.9 mm, with its most anterior point located a mean of 14.1 mm from the tip of the coracoid. The mean length of the CHL attachment along the intra-articular cartilage margin was 10.0 ± 4.0 mm, spanning from 11:55 to 12:40 on the humeral head clockface. CONCLUSION: Glenohumeral ligaments were consistently identified in all specimens with minor anatomic variability for the SGHL, MGHL, AIGHL, and PIGHL. Important landmarks including the cartilage surface of the humerus, the bicipital groove, and the clockface can be utilized intraoperatively when attempting anatomic repair of these structures. CLINICAL RELEVANCE: There are multiple open and arthroscopic shoulder procedures that rely on anatomic restoration of these static stabilizers to provide optimal shoulder function and prevent recurrent instability. The qualitative descriptions are comparable with current literature; however, this study is the first to quantify the glenohumeral capsular and ligamentous attachments. The data provided allow for reliable landmarks to be established from known bony and soft tissue structures.


Asunto(s)
Cabeza Humeral/anatomía & histología , Ligamentos Articulares/anatomía & histología , Articulación del Hombro/anatomía & histología , Cadáver , Humanos , Manguito de los Rotadores/anatomía & histología , Tendones/anatomía & histología
13.
Arthroscopy ; 36(8): 2342-2343, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32360269

RESUMEN

The critical shoulder angle has been associated with the development of rotator cuff lesions. Over time, this association has been interpreted as a cause-effect relation without scientific evidence. Beyond the controversies that exist on the reliability and relevance of this radiographic parameter, the critical shoulder angle per se may not be responsible for rotator cuff tears because patient activities throughout several decades could induce not only cuff lesions but also bone remodeling at the acromial level.


Asunto(s)
Lesiones del Manguito de los Rotadores/etiología , Manguito de los Rotadores/anatomía & histología , Hombro/anatomía & histología , Acromion/anatomía & histología , Humanos , Ortopedia/normas , Reproducibilidad de los Resultados , Manguito de los Rotadores/cirugía , Lesiones del Manguito de los Rotadores/complicaciones , Lesiones del Manguito de los Rotadores/cirugía , Hombro/cirugía , Articulación del Hombro/anatomía & histología
15.
J Invest Surg ; 33(2): 147-158, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30339484

RESUMEN

Aim: Tissue engineering is a contemporary topic, which is widely discussed in shoulder surgery. The preclinical success of tissue engineering has not yet fully translated to clinical studies. In this study, we present our experience in this subject and discuss measurements to analyze the sheep tissue as comparative model. We also present a comprehensive systematic review of the literature in relation to tissue engineering and rotator cuff. Method: We studied the anatomy, histology and surgical approach of 24 infraspinatus tendons specimens in sheep and focused on certain measurements such as: (1) size of the normal tendon; (2) diameter of the normal footprint; and (3) bone hardness of the footprint using a durometer. Blood from six sheep was obtained and processed to produce platelet rich plasma using both the Harvest Smartprep and Cascade kit. We then outlined an approach to the infraspinatus tendon footprint in preparation for implantation of a biological augmentation material, which was repaired using a double row technique. This was followed by a histological analysis. Results: The average measurements of the footprint were 21 mm ×21 mm, the tendon length was 35.1 mm and the width proximal and distal was 21.9 and 14 mm, respectively. The average bone hardness at the 12, 3, 6, and 9 o'clock position was 64.1, 52.3, 50.1, and 37.7 respectively. Central footprint and lateral edge hardness was 44.8 and 43.4. Only the Harvest Smartprep and using a modified method, was able to produce a platelet concentration factor of 4. The Cascade method was unable to concentrate sheep blood. Conclusion: The sheep model is a suitable tissue for studying the rotator cuff. The researcher must be aware of certain interspecies caveats. Clinical tissue engineering and surgical techniques must be modified in order to be suitable when using sheep model.


Asunto(s)
Lesiones del Manguito de los Rotadores/cirugía , Manguito de los Rotadores/trasplante , Técnicas de Sutura , Ingeniería de Tejidos , Animales , Transfusión de Sangre Autóloga , Femenino , Humanos , Modelos Animales , Plasma Rico en Plaquetas , Manguito de los Rotadores/anatomía & histología , Ovinos , Cicatrización de Heridas
16.
J Orthop Sci ; 25(2): 229-234, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30979581

RESUMEN

BACKGROUND: The rotator cable, a semicircular fiber bundle in the lateral portion of the rotator cuff, has been believed to transmit forces among cuff tendons. This study was performed to clarify the functional anatomy of the rotator cable through histoanatomical methods. METHODS: Twenty-two cuff-intact shoulders of fixed cadavers were dissected. The cable was investigated from the cuff surface and articular/bursal sides of the capsule. The width of the cable and distances from the capsule attachment to both of the lateral and medial borders of the cable were measured, and their correlations to the humeral head diameter were calculated. The location of the cable on the humeral head was observed and recorded. In additional five shoulders the cuff/capsule complex and greater tubercle were harvested en block and histologically investigated. RESULTS: The rotator cable was evident in the capsule of 14 shoulders. One specimen demonstrated the cable of double curves. The capsule thickness alteration corresponding to the medial border of the cable with a single curve existed approximately on the so-called 'flexion point' where the humerus started to form a spherical curve from the greater tubercle to the joint surface. The 'flexion point' macroscopically corresponded to the medial boundary of the contact area between the cuff and head. The distance between the cable and capsule attachment showed marked negative correlation to the head diameter. Histologically the cable demonstrated cartilaginous metaplasia and vertical fiber orientation to the supraspinatus. CONCLUSIONS: The rotator cable does not always exist in all the shoulders and its appearances are varied. The location and cartilaginous metaplasia of the cable suggested compression force between the cuff and humeral head, and the force would help cable creation in capsule layer. The vertical fiber orientation of the cable to the supraspinatus would be unlikely to explain force transmission among the cuff tendons.


Asunto(s)
Manguito de los Rotadores/anatomía & histología , Hombro/anatomía & histología , Anciano , Anciano de 80 o más Años , Cadáver , Femenino , Humanos , Masculino
18.
Clin Biomech (Bristol, Avon) ; 72: 115-121, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31862605

RESUMEN

BACKGROUND: The Critical Shoulder Angle was introduced as a combined radiographic surrogate parameter reflecting the influence of the morphological characteristics of the scapula on the development of degenerative shoulder disease such as rotator cuff tears and osteoarthritis. Although, glenoid inclination and lateral extension of the acromion were studied in biomechanical models separately, no investigation included all three individual parameters that determine the Critical Shoulder Angle: glenoid inclination, acromial coverage and acromial height in one cadaveric study protocol. METHODS: Three proximal humerus cadavers were attached to a robotic shoulder simulator which allowed for independent change of either lateral acromial coverage, glenoid inclination or acromial height. Combined dynamic scapula-thoracic and glenohumeral abduction up to 60° with different Critical Shoulder Angle configurations was performed and muscle forces as well as joint reaction forces were recorded. FINDINGS: All three components had an effect on either muscle forces and or joint reaction forces. While glenoid inclination showed the highest impact on joint stability with increasing upward-tilting causing cranial subluxation, changing of the lateral acromial coverage or acromial height had less influence on stability but showed significant alteration of joint reaction forces. INTERPRETATION: All three components of the Critical Shoulder Angle, glenoid inclination, lateral acromial extension and acromial height showed independent biomechanical effects when changed isolated. However, glenoid inclination seems to have the largest impact regarding joint stability.


Asunto(s)
Acromion/anatomía & histología , Cabeza Humeral/anatomía & histología , Fenómenos Mecánicos , Acromion/fisiología , Fenómenos Biomecánicos , Cadáver , Femenino , Humanos , Cabeza Humeral/fisiología , Masculino , Manguito de los Rotadores/anatomía & histología , Manguito de los Rotadores/fisiología , Articulación del Hombro/anatomía & histología , Articulación del Hombro/fisiología
19.
Orthop Traumatol Surg Res ; 106(1): 45-51, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31837930

RESUMEN

BACKGROUND: The pathogenesis of degenerative subscapularis (SC) tear is not clear, several mechanisms are involved: intrinsic tendon degeneration or subcoracoid impingement. The aim of this study was to propose new radiographic markers, the coraco-lesser tuberosity angle (CLA), lesser tuberosity angle (LTA) and lesser tuberosity height (LTH). The hypothesis was that higher values of CLA, LTA, and LTH would be associated with a higher likelihood in detecting a SC tear. METHOD: A total of 114 patients who classified as SC tears through arthroscopic evaluation were retrospectively enrolled in the study from 2016 to 2018. Fifty-seven patients with impingement syndrome were also enrolled as the control group for normal-population comparison. The CLA was measured on an anteroposterior shoulder x-ray image with the arm in neutral rotation, the LTA and LTH were measured on magnetic resonance imaging. Multivariable analyses were used to clarify the potential risks for SC tears. All measurements were calculated by two shoulder surgeons independently measured at 2 different times, 1 month apart. RESULTS: The intra- and inter-observer reliabilities for radiologic measurements and the interobserver reliability of SC tear classification were almost perfect. The mean CLA value of SC tear group (41.4±4.2°) was significantly larger than that of the control group (38.7±4.0°, p<0.001). The mean LTA value of SC tear group (33.4±4.3°) was significantly larger than that of the control group (31.0±3.9°, p=0.001). Mean LTH value was 9.5±1.9mm in patients and 8.9±1.5mm for controls, there was no statistically significant difference (p=0.054). Multivariable analysis showed that larger CLAs significantly increased the risk of SC tears, with odds ratios of 1.17 per degree. Moreover, larger LTAs also significantly increased the risk of SC tears, with odds ratios of 1.14 per degree. CONCLUSION: Our findings confirmed associations between new predictors (CLA and LTA) and SC tears. CLA and LTA values were greater in patients with SC tears than in controls, suggesting that they may be independent risk factors for SC tear onset. LEVEL OF EVIDENCE: IV, retrospective study.


Asunto(s)
Lesiones del Manguito de los Rotadores , Manguito de los Rotadores/anatomía & histología , Articulación del Hombro/anatomía & histología , Estudios de Casos y Controles , Humanos , Imagen por Resonancia Magnética , Reproducibilidad de los Resultados , Estudios Retrospectivos , Manguito de los Rotadores/diagnóstico por imagen , Lesiones del Manguito de los Rotadores/diagnóstico por imagen , Rotura , Articulación del Hombro/diagnóstico por imagen
20.
Vet Rec ; 186(17): e14, 2020 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-31767697

RESUMEN

BACKGROUND: This study aimed to compare the ultrasonographic and histological features of the supraspinatus tendon (ST) and its peculiar appearance in contrast with the biceps brachii tendon. METHODS: For this purpose, 19 non-lame dog cadavers were subjected to an ultrasonographic and histologic evaluation of both shoulders after postmortem examination. RESULTS: Close to their insertion on the greater tubercle, all STs displayed a widened portion with a deep central hypoechoic area lacking a fibrillar pattern, when compared with its more proximal aspect and adjacent biceps brachii. Histologically this deep portion corresponded to poorly organised collagen bundles interspersed within a myxoid substance mainly composed of mucopolysaccharides. This central myxoid area with collagen disarray was responsible for the reduced echogenicity on ultrasound. CONCLUSION: The focal widening of the ST insertion and its central mucopolysaccharidic composition could be an anatomical adaptation to marked forces specifically applied to this tendon. However, the ultrasound and histological appearances are very similar to those described in tendinosis, which represents a confounding factor in diagnosing tendonitis at the insertion of the supraspinatus. In the absence of other ultrasonographic criteria of tendinopathy, a hypoechoic central area in the ST near its insertion should be considered normal.


Asunto(s)
Manguito de los Rotadores/anatomía & histología , Manguito de los Rotadores/diagnóstico por imagen , Animales , Cadáver , Perros , Femenino , Masculino , Estudios Prospectivos , Tendones/anatomía & histología , Tendones/diagnóstico por imagen , Ultrasonografía/veterinaria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...