Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.874
Filtrar
1.
Port J Card Thorac Vasc Surg ; 31(1): 57-58, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38743518

RESUMEN

Surgical resection remains the optimal therapeutic option for early-stage operable NSCLC. Despite significant advances in recent years related to anesthetic and surgical techniques, cardiopulmonary complications remain major causes for postoperative morbimortality. In this paper we present a case of a patient who developed complete AV block followed by asystole after lung resection surgery. The patient underwent surgery via right VATS and the procedure was uneventful.  On the first post-operative day patient developed a third-degree atrioventricular block followed by 6 seconds asystole. Pharmacological treatment was instituted and implementation of a permanent pacemaker occurred on the third post-operative day, without complications. The remaining postoperative course was uneventful and the patient was discharged home on the sixth post-operative day. It is the objective of the authors to report and highlight this rare and potencial fatal complication of lung resection.


Asunto(s)
Bloqueo Atrioventricular , Paro Cardíaco , Neoplasias Pulmonares , Neumonectomía , Humanos , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/diagnóstico , Paro Cardíaco/etiología , Neoplasias Pulmonares/cirugía , Neumonectomía/efectos adversos , Masculino , Carcinoma de Pulmón de Células no Pequeñas/cirugía , Marcapaso Artificial/efectos adversos , Anciano , Cirugía Torácica Asistida por Video/efectos adversos , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología
2.
Forensic Sci Int ; 359: 112001, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38714107

RESUMEN

BACKGROUND: Cardiac implantable electronic devices (CIED) are a heterogeneous group of medical devices with increasingly sophisticated diagnostic capabilities, which could be exploited in forensic investigations. However, current guidelines are lacking clear recommendations on the topic. The first aim of this systematic review is to provide an updated assessment of the role of postmortem CIED interrogation, and to give practical recommendations, which can be used in daily practice. Secondly, the authors aim to determine the rates of postmortem CIED interrogation and autopsy investigations, the type of final rhythm detected close to death (with a focus on the significance of documented arrhythmias), as well as the role of postmortem CIED interrogation in the determination of final cause/time of death, and any potentially fatal device malfunctions. METHODS: A systematic search in MEDLINE and Scopus aiming to identify reports concerning postmortem human CIED interrogation was performed, including a systematic screening of reference lists. Case reports, letters to the editors, commentaries, review articles or guidelines were excluded, along with studies related to cardiac devices other than CIED. All data were pooled and analyzed using fixed-effects meta-analysis models, and the I2 statistic was used to assess heterogeneity. RESULTS: A total of 25 articles were included in the systematic review, enrolling 3194 decedent CIED carriers. Ten studies (40%) had a 100% autopsy rate, whereas in further 6 studies autopsy findings were variably reported; CIED interrogation was available from 22 studies (88%), and it was never performed prior to autopsy. The overall rate of successful postmortem CIED interrogation was 89%, with high heterogeneity among studies, mainly due to device deactivation/battery discharge. Twenty-four percent of CIED carriers experienced sudden cardiac death (SCD), whereas non-sudden cardiac and non-cardiac death (NSCD, NCD) were reported in 37% and 30% of decedents, respectively. Ventricular tachyarrhythmias were recorded in 34% of overall successfully interrogated CIED, and in 62% of decedents who experienced a SCD; of all ventricular tachyarrhythmias recorded, 40% was found in NSCD or NCD. A clear interpretation of the etiological role of recorded arrhythmias in the causation of death required integration with autopsy findings. Overall, potentially fatal device malfunctions were detected in 12% of cases. CONCLUSIONS: Postmortem CIED interrogation is a valuable tool for the determination of the cause of death, and may complement autopsy. Forensic pathologists need to know the potential utility, pitfalls, and limitations of this diagnostic examination to make this tool as much reliable as possible.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Humanos , Marcapaso Artificial/efectos adversos , Arritmias Cardíacas , Falla de Equipo
3.
Arq Bras Cardiol ; 121(4): e20230386, 2024 Apr.
Artículo en Portugués, Inglés | MEDLINE | ID: mdl-38695408

RESUMEN

BACKGROUND: The use of artificial cardiac pacemakers has grown steadily in line with the aging population. OBJECTIVES: To determine the rates of hospital readmissions and complications after pacemaker implantation or pulse generator replacement and to assess the impact of these events on annual treatment costs from the perspective of the Unified Health System (SUS). METHODS: A prospective registry, with data derived from clinical practice, collected during index hospitalization and during the first 12 months after the surgical procedure. The cost of index hospitalization, the procedure, and clinical follow-up were estimated according to the values reimbursed by SUS and analyzed at the patient level. Generalized linear models were used to study factors associated with the total annual treatment cost, adopting a significance level of 5%. RESULTS: A total of 1,223 consecutive patients underwent initial implantation (n=634) or pulse generator replacement (n=589). Seventy episodes of complication were observed in 63 patients (5.1%). The incidence of hospital readmissions within one year was 16.4% (95% CI 13.7% - 19.6%) after initial implants and 10.6% (95% CI 8.3% - 13.4%) after generator replacements. Chronic kidney disease, history of stroke, length of hospital stays, need for postoperative intensive care, complications, and hospital readmissions showed a significant impact on the total annual treatment cost. CONCLUSIONS: The results confirm the influence of age, comorbidities, postoperative complications, and hospital readmissions as factors associated with increased total annual treatment cost for patients with pacemakers.


FUNDAMENTO: O uso de marca-passos cardíacos artificiais tem crescido constantemente, acompanhando o envelhecimento populacional. OBJETIVOS: Determinar as taxas de readmissões hospitalares e complicações após implante de marca-passo ou troca de gerador de pulsos e avaliar o impacto desses eventos nos custos anuais do tratamento sob a perspectiva do Sistema Único de Saúde (SUS). MÉTODOS: Registro prospectivo, com dados derivados da prática clínica assistencial, coletados na hospitalização índice e durante os primeiros 12 meses após o procedimento cirúrgico. O custo da hospitalização índice, do procedimento e do seguimento clínico foram estimados de acordo com os valores reembolsados pelo SUS e analisados ao nível do paciente. Modelos lineares generalizados foram utilizados para estudar fatores associados ao custo total anual do tratamento, adotando-se um nível de significância de 5%. RESULTADOS: No total, 1.223 pacientes consecutivos foram submetidos a implante inicial (n= 634) ou troca do gerador de pulsos (n= 589). Foram observados 70 episódios de complicação em 63 pacientes (5,1%). A incidência de readmissões hospitalares em um ano foi de 16,4% (IC 95% 13,7% - 19,6%) após implantes iniciais e 10,6% (IC 95% 8,3% - 13,4%) após trocas de geradores. Doença renal crônica, histórico de acidente vascular encefálico, tempo de permanência hospitalar, necessidade de cuidados intensivos pós-operatórios, complicações e readmissões hospitalares mostraram um impacto significativo sobre o custo anual total do tratamento. CONCLUSÕES: Os resultados confirmam a influência da idade, comorbidades, complicações pós-operatórias e readmissões hospitalares como fatores associados ao incremento do custo total anual do tratamento de pacientes com marca-passo.


Asunto(s)
Marcapaso Artificial , Readmisión del Paciente , Humanos , Marcapaso Artificial/economía , Marcapaso Artificial/efectos adversos , Femenino , Masculino , Anciano , Persona de Mediana Edad , Readmisión del Paciente/estadística & datos numéricos , Readmisión del Paciente/economía , Factores de Tiempo , Anciano de 80 o más Años , Estudios Prospectivos , Complicaciones Posoperatorias/economía , Brasil , Costos de la Atención en Salud/estadística & datos numéricos , Factores de Riesgo , Tiempo de Internación/economía
5.
Sci Rep ; 14(1): 10440, 2024 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-38714750

RESUMEN

A wide variety of treatments have been developed to improve respiratory function and quality of life in patients with bilateral vocal fold paresis (BVFP). One experimental method is the electrical activation of the posterior cricoarytenoid (PCA) muscle with a laryngeal pacemaker (LP) to open the vocal folds. We used an ovine (sheep) model of unilateral VFP to study the long-term effects of functional electrical stimulation on the PCA muscles. The left recurrent laryngeal nerve was cryo-damaged in all animals and an LP was implanted except for the controls. After a reinnervation phase of six months, animals were pooled into groups that received either no treatment, implantation of an LP only, or implantation of an LP and six months of stimulation with different duty cycles. Automated image analysis of fluorescently stained PCA cross-sections was performed to assess relevant muscle characteristics. We observed a fast-to-slow fibre type shift in response to nerve damage and stimulation, but no complete conversion to a slow-twitch-muscle. Fibre size, proportion of hybrid fibres, and intramuscular collagen content were not substantially altered by the stimulation. These results demonstrate that 30 Hz burst stimulation with duty cycles of 40% and 70% did not induce PCA atrophy or fibrosis. Thus, long-term stimulation with an LP is a promising approach for treating BVFP in humans without compromising muscle conditions.


Asunto(s)
Modelos Animales de Enfermedad , Terapia por Estimulación Eléctrica , Músculos Laríngeos , Parálisis de los Pliegues Vocales , Animales , Ovinos , Parálisis de los Pliegues Vocales/terapia , Parálisis de los Pliegues Vocales/fisiopatología , Terapia por Estimulación Eléctrica/métodos , Músculos Laríngeos/fisiopatología , Humanos , Marcapaso Artificial/efectos adversos , Pliegues Vocales/fisiopatología , Pliegues Vocales/patología , Femenino
6.
Rev Assoc Med Bras (1992) ; 70(4): e20230998, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38716936

RESUMEN

OBJECTIVE: The use of cardiac implantable electronic devices has increased in recent years. It has also brought some issues. Among these, the complications of cardiac implantable electronic devices infection and pocket hematoma are difficult to manage. It can be fatal with the contribution of patient-related risk factors. In this study, we aimed to find mortality rates in patients who developed cardiac implantable electronic devices infection and pocket hematoma over 5 years. We also investigated the risk factors affecting mortality in patients with cardiac implantable electronic devices. METHODS: A total of 288 cardiac implantable electronic devices patients were evaluated. Demographic details, history, and clinical data of all patients were recorded. Cardiac implantable electronic devices infection was defined according to the modified Duke criteria. The national registry was used to ascertain the mortality status of the patients. The patients were divided into two groups (exitus and survival groups). In addition, the pocket hematoma was defined as significant bleeding at the pocket site after cardiac implantable electronic devices placement. RESULTS: The cardiac implantable electronic devices infection was similar in both groups (p=0.919), and the pocket hematoma was higher in the exitus group (p=0.019). The exitus group had higher usage of P2Y12 inhibitors (p≤0.001) and novel oral anticoagulants (p=0.031). The Cox regression analysis, including mortality-related factors, revealed that renal failure is the most significant risk factor for mortality. Renal failure was linked to a 2.78-fold higher risk of death. CONCLUSION: No correlation was observed between cardiac implantable electronic devices infection and mortality, whereas pocket hematoma was associated with mortality. Furthermore, renal failure was the cause of the highest mortality rate in patients with cardiac implantable electronic devices.


Asunto(s)
Desfibriladores Implantables , Hematoma , Marcapaso Artificial , Humanos , Femenino , Masculino , Desfibriladores Implantables/efectos adversos , Factores de Riesgo , Anciano , Persona de Mediana Edad , Marcapaso Artificial/efectos adversos , Hematoma/etiología , Hematoma/mortalidad , Infecciones Relacionadas con Prótesis/mortalidad , Infecciones Relacionadas con Prótesis/etiología , Estudios Retrospectivos , Factores de Tiempo , Anciano de 80 o más Años
8.
J Am Coll Cardiol ; 83(20): 2002-2014, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38749619

RESUMEN

Orthotopic transcatheter tricuspid valve replacement (TTVR) devices have been shown to be highly effective in reducing tricuspid regurgitation (TR), and interest in this therapy is growing with the recent commercial approval of the first orthotopic TTVR. Recent TTVR studies report preexisting cardiac implantable electronic device (CIED) transvalvular leads in ∼35% of patients, with entrapment during valve implantation. Concerns have been raised regarding the safety of entrapping leads and counterbalanced against the risks of transvenous lead extraction (TLE) when indicated. This Heart Valve Collaboratory consensus document attempts to define the patient population with CIED lead-associated or lead-induced TR, describe the risks of lead entrapment during TTVR, delineate the risks and benefits of TLE in this setting, and develop a management algorithm for patients considered for TTVR. An electrophysiologist experienced in CIED management should be part of the multidisciplinary heart team and involved in shared decision making.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Desfibriladores Implantables/efectos adversos , Marcapaso Artificial/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Índice de Severidad de la Enfermedad
9.
Card Electrophysiol Clin ; 16(2): 139-142, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38749632

RESUMEN

This case report discusses a 42-year-old male with dextro-transposition of the great arteries (D-TGA) status post Mustard repair and sick sinus syndrome status post dual-chamber pacemaker implant, who developed symptomatic superior vena cava (SVC) baffle stenosis. He was treated with a combined pacemaker extraction and subsequent SVC baffle stenting. The case highlights the complexities of treating SVC baffle stenosis in the presence of cardiac implantable devices and demonstrates the efficacy of this combined approach. Furthermore, the authors delve into the intricacies of D-TGA, its surgical history, and the long-term complications associated with atrial switch procedures.


Asunto(s)
Remoción de Dispositivos , Marcapaso Artificial , Stents , Transposición de los Grandes Vasos , Humanos , Transposición de los Grandes Vasos/cirugía , Masculino , Adulto , Marcapaso Artificial/efectos adversos , Síndrome de la Vena Cava Superior/cirugía , Síndrome de la Vena Cava Superior/etiología , Síndrome del Seno Enfermo/terapia , Síndrome del Seno Enfermo/cirugía
10.
Card Electrophysiol Clin ; 16(2): 143-147, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38749633

RESUMEN

We present a complex case of cardiac implantable electronic device infection and extraction in the setting of bacteremia, large lead vegetation, and patent foramen ovale. Following a comprehensive preprocedural workup including transesophageal echocardiogram and computed tomography lead extraction protocol, in addition to the involvement of multiple subspecialties, an open chest approach to extraction was deemed a safer option for eradication of the patient's infection. Despite percutaneous techniques having evolved as the preferred extraction method during the last few decades, this case demonstrates the importance of a thorough evaluation at an experienced center to determine the need for open chest extraction.


Asunto(s)
Desfibriladores Implantables , Remoción de Dispositivos , Marcapaso Artificial , Infecciones Relacionadas con Prótesis , Humanos , Remoción de Dispositivos/métodos , Desfibriladores Implantables/efectos adversos , Infecciones Relacionadas con Prótesis/cirugía , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Marcapaso Artificial/efectos adversos , Masculino , Ecocardiografía Transesofágica , Tomografía Computarizada por Rayos X , Anciano , Foramen Oval Permeable/cirugía , Foramen Oval Permeable/diagnóstico por imagen , Femenino , Persona de Mediana Edad
11.
Card Electrophysiol Clin ; 16(2): 117-124, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38749629

RESUMEN

Transvenous laser lead extraction poses a risk of major complications (0.19%-1.8%), notably injury to the superior vena cava (SVC) in 0.19% to 0.96% of cases. Various factors contribute to SVC injury, which can be categorized as patient-related (such as female gender, low body mass index, diabetes, renal problems, anemia, and reduced ejection fraction), device-related (including the number, dwell time, and type of leads), or procedural-related (such as reason for extraction, venous obstructions, and bilateral lead placements).


Asunto(s)
Remoción de Dispositivos , Terapia por Láser , Vena Cava Superior , Humanos , Vena Cava Superior/lesiones , Vena Cava Superior/cirugía , Femenino , Remoción de Dispositivos/efectos adversos , Masculino , Terapia por Láser/efectos adversos , Persona de Mediana Edad , Anciano , Desfibriladores Implantables/efectos adversos , Marcapaso Artificial/efectos adversos
12.
Card Electrophysiol Clin ; 16(2): 157-161, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38749635

RESUMEN

Cardiac implantable electronic device leads can contribute to tricuspid regurgitation and also complicate surgical and transcatheter interventions to manage tricuspid regurgitation. Here we present a case of a patient with sinus node dysfunction and complete heart block who underwent extraction of a right ventricular pacing lead before tricuspid valve surgery. We review the data regarding the contribution of leads to tricuspid regurgitation and the benefits of lead extraction, risks of jailing leads during tricuspid interventions, and pacing considerations around tricuspid valve procedures.


Asunto(s)
Marcapaso Artificial , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Marcapaso Artificial/efectos adversos , Masculino , Anciano , Bloqueo Cardíaco/terapia , Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Femenino
13.
J Am Coll Cardiol ; 83(14): 1326-1337, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38569763

RESUMEN

Cardiac implantable electronic device-related infective endocarditis (CIED-IE) encompasses a range of clinical syndromes, including valvular, device lead, and bloodstream infections. However, accurately diagnosing CIED-IE remains challenging owing in part to diverse clinical presentations, lack of standardized definition, and variations in guideline recommendations. Furthermore, current diagnostic modalities, such as transesophageal echocardiography and [18F]-fluorodeoxyglucose positron emission tomography-computed tomography have limited sensitivity and specificity, further contributing to diagnostic uncertainty. This can potentially result in complications and unnecessary costs associated with inappropriate device extraction. Six hypothetical clinical cases that exemplify the diverse manifestations of CIED-IE are addressed herein. Through these cases, we highlight the importance of optimizing diagnostic accuracy and stewardship, understanding different pathogen-specific risks for bloodstream infections, guiding appropriate device extraction, and preventing CIED-IE, all while addressing key knowledge gaps. This review both informs clinicians and underscores crucial areas for future investigation, thereby shedding light on this complex and challenging syndrome.


Asunto(s)
Desfibriladores Implantables , Endocarditis Bacteriana , Endocarditis , Marcapaso Artificial , Infecciones Relacionadas con Prótesis , Sepsis , Humanos , Desfibriladores Implantables/efectos adversos , Marcapaso Artificial/efectos adversos , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/etiología , Endocarditis/diagnóstico , Endocarditis/etiología , Endocarditis Bacteriana/complicaciones
14.
Medicine (Baltimore) ; 103(16): e37543, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38640303

RESUMEN

BACKGROUND: Tachycardia-bradycardia syndrome (TBS) is a subtype of sick sinus syndrome characterized by prolonged sinus pause (≥3 s) following termination of tachyarrhythmias, primarily atrial fibrillation (AF). There is controversy regarding whether the long-term prognosis of AF ablation is superior to pacemaker implantation. This study aimed to compare the effects of AF ablation and pacemaker therapy in patients with TBS. METHODS: We conducted a comprehensive search of electronic databases, including PubMed, Cochrane, EmBase, Web of Science, and Chinese BioMedical, up until December 1, 2023. We included studies that reported the effects of AF ablation vs pacemaker therapy in patients with TBS. From this search, we identified 5 studies comprising 843 participants with TBS who underwent catheter AF ablation or pacemaker therapy. RESULTS: Our meta-analysis revealed that AF ablation and pacemaker therapy had similar effects on cardiovascular death (odds ratio [OR] = 0.62 and 95% confidence interval [CI]: 0.14-2.65), procedural complications (OR = 1.53 and 95% CI: 0.67-3.48), and cardiovascular rehospitalization (OR = 0.57 and 95% CI: 0.26-1.22). However, AF ablation provided greater benefits than pacemaker therapy in terms of all-cause mortality (OR = 0.37 and 95% CI: 0.17-0.82), thromboembolism (OR = 0.25 and 95% CI: 0.12-0.49), stroke (OR = 0.28 and 95% CI: 0.13-0.57), heart failure (OR = 0.27 and 95% CI: 0.13-0.56), freedom from AF (OR = 23.32 and 95% CI: 7.46-72.92), and prevention of progression to persistent AF (OR = 0.12 and 95% CI: 0.06-0.24). Furthermore, AF ablation resulted in a reduced need for antiarrhythmic agents (OR = 0.21 and 95% CI: 0.08-0.59). CONCLUSION: AF ablation can effectively reduce the risk of all-cause mortality, thromboembolism, stroke, heart failure, and progression to persistent AF in patients with TBS. Additionally, it may eliminate the need for further pacemaker therapy in most cases after ablation. Therefore, AF ablation is considered superior to pacemaker therapy in the management of patients with TBS.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Insuficiencia Cardíaca , Marcapaso Artificial , Accidente Cerebrovascular , Tromboembolia , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/terapia , Síndrome del Seno Enfermo/terapia , Bradicardia/terapia , Resultado del Tratamiento , Marcapaso Artificial/efectos adversos , Taquicardia/terapia , Ablación por Catéter/métodos , Accidente Cerebrovascular/etiología , Insuficiencia Cardíaca/etiología , Tromboembolia/etiología
15.
Int Breastfeed J ; 19(1): 27, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38641819

RESUMEN

BACKGROUND: Lactational mastitis is a common painful and debilitating inflammation of breast tissue, generally treated conservatively or with pus puncture in case of breast abscess. However, treating mastitis in patients with implantable surgical material located in the affected breast region can be extremely challenging. We present an unusual case of lactational mastitis complicated by pacemaker pocket infection in a breastfeeding mother. CASE PRESENTATION: A 35-year-old pacemaker-dependent female developed lactational mastitis seven weeks postpartum. Initially, the condition was treated conservatively with analgesics and antibiotics. After abscess formation, pus was aspirated using fine-needle aspiration technique. Four weeks after mastitis resolution, pacemaker pocket infection developed. According to current cardiovascular implantable electronic device infection treatment guidelines a complete surgical extraction of the entire electronic system, followed by targeted antibiotic treatment and reimplantation of a new device after infection resolution, was recommended. However, after thorough discussion with the young woman and her family and after detailed review of surgery-related risks, she declined a potentially high-risk surgical procedure. Thus, only the pulse generator was explanted; pacing leads positioned in the sub-pectoral pocket; new pacemaker implanted on the contralateral side and broad-spectrum antibiotic therapy continued for six weeks. After breastfeeding cessation, and with chronic fistula development at the primary pacemaker implantation site, the possibility of delayed surgical intervention including complete extraction of retained pacemaker leads was again thoroughly discussed with her. After thoughtful consideration the woman consented to the proposed treatment strategy. A surgical procedure including transvenous lead extraction through the primary implantation venous entry site, using hand-powered bidirectional rotational sheaths, was successfully performed, removing all retained leads through the left subclavian venous entry site, and leaving the fully functional and clinically uninfected pacemaker on the contralateral site intact. CONCLUSION: Although patients' decisions for delayed extraction in a case of cardiovascular implantable electronic device infection should be discouraged by attending physicians and members of interdisciplinary teams, our case shows that a stepwise treatment strategy may be successful as a bailout clinical scenario in patients with specific requests, demands and / or clinical needs.


Asunto(s)
Mastitis , Marcapaso Artificial , Humanos , Femenino , Adulto , Lactancia Materna , Absceso/tratamiento farmacológico , Mastitis/terapia , Marcapaso Artificial/efectos adversos , Lactancia , Antibacterianos/uso terapéutico
16.
J Am Coll Cardiol ; 83(17): 1656-1668, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38658105

RESUMEN

BACKGROUND: Tricuspid valve annuloplasty (TA) during mitral valve repair (MVr) is associated with increased risk of permanent pacemaker (PPM) implantation, but the magnitude of risk and long-term clinical consequences have not been firmly established. OBJECTIVES: This study assesses the incidence rates of PPM implantation after isolated MVr and following MVr with TA as well as the associated long-term clinical consequences of PPM implantation. METHODS: State-mandated hospital discharge databases of New York and California were queried for patients undergoing MVr (isolated or with concomitant TA) between 2004 and 2019. Patients were stratified by whether or not they received a PPM within 90 days of index surgery. After weighting by propensity score, survival, heart failure hospitalizations (HFHs), endocarditis, stroke, and reoperation were compared between patients with or without PPM. RESULTS: A total of 32,736 patients underwent isolated MVr (n = 28,003) or MVr + TA (n = 4,733). Annual MVr + TA volumes increased throughout the study period (P < 0.001, trend), and PPM rates decreased (P < 0.001, trend). The incidence of PPM implantation <90 days after surgery was 7.7% for MVr and 14.0% for MVr + TA. In 90-day conditional landmark-weighted analyses, PPMs were associated with reduced long-term survival among MVr (HR: 1.96; 95% CI: 1.75-2.19; P < 0.001) and MVr + TA recipients (HR: 1.65; 95% CI: 1.28-2.14; P < 0.001). In both surgical groups, PPMs were also associated with an increased risk of HFH (HR: 1.56; 95% CI: 1.27-1.90; P < 0.001) and endocarditis (HR: 1.95; 95% CI: 1.52-2.51; P < 0.001), but not with stroke or reoperation. CONCLUSIONS: Compared to isolated MVr, adding TA to MVr was associated with a higher risk of 90-day PPM implantation. In both surgical groups, PPM implantation was associated with an increase in mortality, HFH, and endocarditis.


Asunto(s)
Marcapaso Artificial , Válvula Tricúspide , Humanos , Femenino , Masculino , Anciano , Marcapaso Artificial/efectos adversos , Válvula Tricúspide/cirugía , Persona de Mediana Edad , Válvula Mitral/cirugía , Estudios Retrospectivos , Anuloplastia de la Válvula Cardíaca/efectos adversos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Resultado del Tratamiento
17.
Tex Heart Inst J ; 51(1)2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38564374

RESUMEN

This report discusses a case of transient 2:1 atrioventricular block with conduction system pacing 4 hours after leadless right ventricular pacemaker implantation in a 19-year-old patient with a history of cardioinhibitory syncope and asystole cardiac arrest but without preexisting atrioventricular block. The atrioventricular block was resolved spontaneously. Pacing morphology was suggestive of right bundle branch pacing. Neither 2:1 atrioventricular block nor conduction system pacing has previously been a reported outcome of right ventricular leadless pacemaker implantation. The report demonstrates that conduction system pacing with leadless devices is achievable. Further study of techniques, limitations, and complications related to intentional right ventricular leadless conduction system pacing is warranted.


Asunto(s)
Bloqueo Atrioventricular , Marcapaso Artificial , Humanos , Adulto Joven , Adulto , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/terapia , Bloqueo Atrioventricular/etiología , Estimulación Cardíaca Artificial/métodos , Marcapaso Artificial/efectos adversos , Sistema de Conducción Cardíaco , Ventrículos Cardíacos , Resultado del Tratamiento
18.
Tex Heart Inst J ; 51(1)2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38680081

RESUMEN

Transcatheter aortic valve replacement is quickly becoming the standard of care for patients with severe aortic stenosis thanks to its minimally invasive nature and favorable outcomes. Recently, left ventricular pacing has been proposed as a safer alternative to traditional right heart pacing, which could simplify the transcatheter aortic valve replacement procedure overall, although procedural complications may still occur. This report describes a rare case of left ventricular pacing wire-induced acute severe mitral valve regurgitation during transcatheter aortic valve replacement.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia de la Válvula Mitral , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/fisiopatología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Enfermedad Aguda , Anciano de 80 o más Años , Estimulación Cardíaca Artificial/métodos , Masculino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Resultado del Tratamiento , Función Ventricular Izquierda/fisiología , Marcapaso Artificial/efectos adversos , Femenino , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen
19.
J Cardiovasc Electrophysiol ; 35(5): 1017-1025, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38501386

RESUMEN

Tricuspid regurgitation (TR) secondary to cardiac implantable electronic devices (CIEDs) has been well documented and is associated with worse cardiovascular outcomes. A variety of mechanisms have been proposed including lead-induced mechanical disruption of the tricuspid valvular or subvalvular apparatus and pacing-induced electrical dyssynchrony. Patient characteristics such as age, sex, baseline atrial fibrillation, and pre-existing TR have not been consistent predictors of CIED-induced TR. While two-dimensional echocardiography is helpful in assessing the severity of TR, three-dimensional echocardiography has significantly improved accuracy in identifying the etiology of TR and whether lead position contributes to TR. Three-dimensional echocardiography may therefore play a future role in optimizing lead positioning during implant to reduce the risk of CIED-induced TR. Optimal lead management strategies in addition to percutaneous interventions and surgery in alleviating TR are very important.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/cirugía , Desfibriladores Implantables/efectos adversos , Marcapaso Artificial/efectos adversos , Válvula Tricúspide/fisiopatología , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Factores de Riesgo , Resultado del Tratamiento , Ecocardiografía Tridimensional
20.
BMJ Case Rep ; 17(3)2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38514158

RESUMEN

Flecainide is a Vaughan Williams class 1c antiarrhythmic used to treat supraventricular and ventricular arrhythmias. It has been described as a rare cause for increased pacemaker capture thresholds. We describe a report of a patient, in her early 80s, presenting with tachy-brady syndrome on a background of permanent atrial fibrillation. She was treated with metoprolol and flecainide by her private cardiologist. Permanent right ventricular chamber pacing was recommended for her slow heart rate. At insertion of her single chamber pacemaker, she was noted to have elevated capture thresholds despite appropriate lead positioning. A flecainide level was elevated at 1.1 µg/mL, and it was subsequently ceased. This was associated with a rapid improvement in her capture threshold. Flecainide should be considered as a cause for elevated pacing thresholds at the time of implant. Particular care should be taken for at-risk groups such as the elderly and patients with renal impairment.


Asunto(s)
Fibrilación Atrial , Marcapaso Artificial , Femenino , Humanos , Anciano , Flecainida/efectos adversos , Antiarrítmicos/efectos adversos , Marcapaso Artificial/efectos adversos , Fibrilación Atrial/etiología , Bradicardia/etiología , Estimulación Cardíaca Artificial
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...