Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Intervalo de año de publicación
1.
J Invasive Cardiol ; 21(8): 378-82, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19652248

RESUMEN

BACKGROUND: Semisynthetic coating of the Camouflage bare-metal stent (BMS) (Eucatech AG, Rheinfelden, Germany) mimics luminal endothelial cell glycocalix, potentially preventing the activation of the coagulation system. Purpose. We sought to determine in a clinical registry the acute and long-term clinical and angiographic outcomes of this BMS design in patients with acute coronary syndromes (ACS) or who were unable to be on long-term clopidogrel therapy. METHODS: From March 2007 to December 2008, 150 patients undergoing coronary stent implantation at three centers in Buenos Aires, Argentina, were included in our registry. Patients with ACS, including non-ST-elevation myocardial infarction (NSTEMI) and STelevation MI (STEMI), or those unable to be on long-term dual antiplatelet therapy were considered for inclusion. The primary endpoint was a major adverse cardiovascular event (MACE) defined as the incidence of cardiac death, MI or target lesion revascularization (TLR). The incidence of acute and late stent thrombosis (ST) was also analyzed. Angiographic late loss and the presence of late stent malapposition (LSM) was recorded at 9-month follow up. Clopidogrel was prescribed for 1 month. RESULTS: 54.7% of patients had acute MI, 36% had STEMI and 20.7% of patients were ineligible for long-term clopidogrel therapy because of previously planned non-vascular or general surgery within 30 days after percutaneous coronary intervention. During 11.5 months of clinical follow up, 2% suffered cardiac death, 4% had a MI, 8.9% underwent TLR and the overall cumulative major adverse cardiac event rate was 15.3%. No patient developed acute or late ST. There were no in-hospital complications for patients who underwent surgery. Intravascular ultrasound studies did not detect the presence of late malapposition. CONCLUSION: In this high-risk thrombotic patient population, the Camouflage coated stent design demonstrated a very good safety profile, as reflected by the low incidence of hard adverse cardiac events including ST at follow up.


Asunto(s)
Materiales Biocompatibles Revestidos , Enfermedad Coronaria/terapia , Trombosis Coronaria/prevención & control , Diseño de Equipo , Sistema de Registros , Stents , Anciano , Argentina , Clopidogrel , Materiales Biocompatibles Revestidos/efectos adversos , Angiografía Coronaria , Trombosis Coronaria/epidemiología , Diseño de Equipo/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Infarto del Miocardio/epidemiología , Infarto del Miocardio/prevención & control , Inhibidores de Agregación Plaquetaria/uso terapéutico , Estudios Prospectivos , Estudios Retrospectivos , Factores de Riesgo , Stents/efectos adversos , Ticlopidina/análogos & derivados , Ticlopidina/uso terapéutico , Resultado del Tratamiento
3.
Rev. bras. cardiol. invasiva ; 15(3): 234-239, jul.-set. 2007. tab, graf
Artículo en Portugués | LILACS, Sec. Est. Saúde SP | ID: lil-469928

RESUMEN

Introdução: O estudo STEALTH I demonstrou a eficácia e segurança dos stents eluidores de Biolimus A (BA9) em reduzir a perda-tardia angiográfica e apresentar uma baixa incidência de eventos cardíacos maiores, entretanto os achados de ultra-som intracoronário (USIC) ainda não foram descritos. O objetivo deste estudo é descrever os achados de análise volumétrica por USIC nos pacientes recrutados em nossa instituição. Métodos e Resultados: Quarenta e cinco pacientes apresentando lesão coronária de novo, única, foram randomizados 2:1 para receber stents eluidores de BA9 (n igual 30) ou stents controle (n igual 15). A média de idade foi de 58 anos, com 16 por cento diabéticos e 62 por cento do sexo masculino. As características clínicas e angiográficas foram similares entre os grupos. Aos 6 meses de seguimento não houve diferença significativa entre os grupos quanto a desfechos clínicos. O índice de hiperplasia intimal intra-stent foi inferior no grupo dos stents eluidores de BA9 em comparação ao grupo controle 0,19 mais/menos 0,08 vs. 2.71 mais/menos 0.50, ) menor 0.0001), assim como o percentual de obstrução...


Background: Biolimus A9 (BA9) is a novel sirolimus analog with similar antiproliferative properties. BA9-eluting stents reduce angiographic late-loss compared to bare metal stents (BMS), with a low incidence of major adverse cardiac events (MACE), as reported in the randomized, controlled STEALTH I trial. We describe the intravascular ultrasound (IVUS) volumetric findings of patients enrolled at our institution. Methods and Results: Forty-five patients presenting a single, de novo coronary lesion (2.5-4.0 mm vessels; lesion length <24 mm) were randomly assigned in a 2:1 basis to receive either BA9-eluting (n=30) or bare metal stents (n=15). Mean age was 58 years, with 16% diabetics and 62% men. Baseline clinical and angiographic characteristics were similar between groups. At 6 month follow-up, there was no statistical difference in clinical outcomes between groups. In-stent intimal hyperplasia index measured by IVUS was 0.19+/-0.08 mm3/ mm3 for the BA9 group vs. 2.71+/-0.50 mm3/mm3 for BMS controls. The percentage of stent obstruction was also significantly lower for the BA9 group when compared to BMS (2.2+/-0.80% vs. 19.9+/-4.67%, P<0.0001). No stent thrombosis, aneurysm formation or incomplete stent apposition was observed in any group. Conclusions: Using IVUS volumetric analysis, we showed that BA9-eluting stents have a potent inhibitory effect on neointimal proliferation when compared to BMS at 6-month follow-up.


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Stents , Reestenosis Coronaria/complicaciones , Reestenosis Coronaria/diagnóstico , Sirolimus/análogos & derivados , Materiales Biocompatibles Revestidos/efectos adversos
4.
Int J Oral Maxillofac Implants ; 19(6): 839-48, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15623059

RESUMEN

PURPOSE: Tissue reactions to 4 different implant surfaces were evaluated in regard to the development and progression of ligature-induced peri-implantitis. MATERIALS AND METHODS: In 6 male mongrel dogs, a total of 36 dental implants with different surfaces (9 titanium plasma-sprayed, 9 hydroxyapatite-coated, 9 acid-etched, and 9 commercially pure titanium) were placed 3 months after mandibular premolar extraction. After 3 months with optimal plaque control, abutment connection was performed. Forty-five days later, cotton ligatures were placed around the implants to induce peri-implantitis. At baseline and 20, 40, and 60 days after placement, the presence of plaque, peri-implant mucosal redness, bleeding on probing, probing depth, clinical attachment loss, mobility, vertical bone loss, and horizontal bone loss were assessed. RESULTS: The results did not show significant differences among the surfaces for any parameter during the study (P > .05). All surfaces were equally susceptible to ligature-induced peri-implantitis over time (P < .001). Correlation analysis revealed a statistically significant relationship between width of keratinized tissue and vertical bone loss (r2 = 0.81; P = .014) and between mobility and vertical bone loss (r2 = 0.66; P = .04), both for the titanium plasma-sprayed surface. DISCUSSION AND CONCLUSIONS: The present data suggest that all surfaces were equally susceptible to experimental peri-implantitis after a 60-day period.


Asunto(s)
Implantes Dentales/efectos adversos , Periodontitis/etiología , Pérdida de Hueso Alveolar/etiología , Análisis de Varianza , Animales , Materiales Biocompatibles Revestidos/efectos adversos , Implantación Dental Endoósea/efectos adversos , Retención de Prótesis Dentales , Fracaso de la Restauración Dental , Perros , Implantes Experimentales/efectos adversos , Ligadura , Masculino , Periodontitis/patología , Radiografía Dental Digital , Propiedades de Superficie , Titanio/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA