Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 618
Filtrar
1.
Sci Rep ; 14(1): 9279, 2024 04 23.
Artículo en Inglés | MEDLINE | ID: mdl-38654039

RESUMEN

A simple and rapid electrochemical sensing method with high sensitivity and specificity of aptamers was developed for the detection of methylamphetamine (MAMP). A short anti-MAMP thiolated aptamer (Apt) with a methylene blue (MB) probe at 3'-end was immobilized on the surface of a gold electrode (MB-Apt-S/GE). The electrochemical signal appeared when MAMP presenting in the sample solution competed with cDNA for binding with MB-Apt-S. Under optimized conditions, the liner range of this signal-on electrochemical aptasensor for the detection of MAMP achieved from 1.0 to 10.0 nmol/L and 10.0-400 nmol/L. LOD 0.88 nmol/L were obtained. Satisfactory spiked recoveries of saliva and urine were also obtained. In this method, only 5 min were needed to incubate before the square wave voltammetry (SWV) analysis, which was much more rapid than other electrochemical sensors, leading to a bright and broad prospect for the detection of MAMP in biological sample. This method can be used for on-site rapid detection on special occasions, such as drug driving scenes, entertainment venues suspected of drug use, etc.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Técnicas Electroquímicas , Metanfetamina , Técnicas Electroquímicas/métodos , Técnicas Biosensibles/métodos , Aptámeros de Nucleótidos/química , Humanos , Metanfetamina/orina , Metanfetamina/análisis , ADN Complementario/genética , Saliva/química , Saliva/metabolismo , Electrodos , Límite de Detección , Oro/química , Azul de Metileno/química
2.
Anal Biochem ; 691: 115526, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38621604

RESUMEN

The imperative for the point-of-care testing of methamphetamine and cocaine in drug abuse prevention necessitates innovative solutions. To address this need, we have introduced a multi-channel wearable sensor harnessing CRISPR/Cas12a system. A CRISPR/Cas12a based system, integrated with aptamers specific to methamphetamine and cocaine, has been engineered. These aptamers function as signal-mediated intermediaries, converting methamphetamine and cocaine into nucleic acid signals, subsequently generating single-stranded DNA to activate the Cas12 protein. Additionally, we have integrated a microfluidic system and magnetic separation technology into the CRISPR system, enabling rapid and precise detection of cocaine and methamphetamine. The proposed sensing platform demonstrated exceptional sensitivity, achieving a detection limit as low as 0.1 ng/mL. This sensor is expected to be used for on-site drug detection in the future.


Asunto(s)
Cocaína , Metanfetamina , Pruebas en el Punto de Atención , Dispositivos Electrónicos Vestibles , Cocaína/análisis , Metanfetamina/análisis , Humanos , Técnicas Biosensibles/métodos , Aptámeros de Nucleótidos/química , Sistemas CRISPR-Cas , Detección de Abuso de Sustancias/métodos
3.
Addiction ; 119(6): 1013-1020, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38509858

RESUMEN

BACKGROUND AND AIMS: The use and manufacture of methamphetamine has increased in Afghanistan in recent years. Recent research and reports have pointed to the ephedra plant, which grows wildly, as a key source of ephedrine used in the manufacture of methamphetamine. This paper aimed to estimate the relative efficiencies and scale of inputs required to manufacture methamphetamine in Afghanistan. METHODS: Monte Carlo simulations model of the amount of ephedra or cold medications needed to render a pure kilogram of methamphetamine in Afghanistan, accounting for uncertainty in ranges of key parameters informed from the literature and elsewhere. Final estimates were extrapolated to recent seizure totals. RESULTS: For dried ephedra, the median estimate is 196.8 kg (25th-75th percentiles 119.3-346.6 kg) needed to produce 1 kg of methamphetamine compared with 27.9 kg (25th-75th percentiles 21.9-36.8 kg) for cold medications. Nearly 2.7 t of methamphetamine were seized in Afghanistan in 2021. Assuming a purity range of 50%-90%, some 266-478 t of dried ephedra or 38-68 t of cold medication would need to have been processed. CONCLUSION: Simulated estimates show that considerable amounts of either ephedra or cold medication are needed to produce 1 kg of methamphetamine in Afghanistan. This raises questions about the plausibility of ephedra as the dominant source of Afghanistan's methamphetamine.


Asunto(s)
Metanfetamina , Método de Montecarlo , Metanfetamina/análisis , Afganistán , Humanos , Ephedra , Estimulantes del Sistema Nervioso Central/análisis , Efedrina/análisis , Drogas Ilícitas/análisis
4.
J Forensic Sci ; 69(3): 1011-1020, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38351585

RESUMEN

Recreational methamphetamine production and heavy use can result in dwelling contamination that is difficult to detect. First responders and public health officials may use commercially available trace methamphetamine detection (presumptive) test kits to understand apparent and hidden dangers in impacted dwellings. Here, we assessed the limit of detection (LOD) of several commercially available presumptive test kits using simulated contaminated hard surfaces. Pyrex petri dishes were spiked with aliquots of methanolic methamphetamine solutions to reach desired simulated contamination levels. Commercially available presumptive tests were conducted according to manufacturer instructions and using included sample preparation materials, when available. Additionally, a laboratory-based liquid chromatography-triple quadrupole mass spectrometer (LC-MS/MS) trace methamphetamine quantification method was developed and validated using the EZSTATSG2 tool. For the LC-MS/MS method, samples were collected using 2-ply alcohol prep pads and methamphetamine was extracted using a 1:1 (v:v) methanol: water solution. Most presumptive tests considered were able to detect trace levels of methamphetamine extracted from hard surfaces, with LOD ranging from 0.10-15.00 µg/sample. Comparatively, the laboratory-based LC-MS/MS LOD was 0.05 µg/sample and limit of quantitation was 0.10 µg/sample. The LC-MS/MS method may be useful when the presence of dust or other contaminants interferes with presumptive test interpretation or reliability. Costs of presumptive tests varied from several dollars to tens of dollars, which is included alongside LOD results to aid stakeholders in identifying which test(s) are the best fit for purpose. Therefore, first responders, public health officials, and other stakeholders have several options for assessing trace methamphetamine contamination.


Asunto(s)
Toxicología Forense , Límite de Detección , Metanfetamina , Metanfetamina/análisis , Cromatografía Liquida , Humanos , Toxicología Forense/métodos , Estimulantes del Sistema Nervioso Central/análisis , Espectrometría de Masas en Tándem , Propiedades de Superficie , Espectrometría de Masas/métodos , Cromatografía Líquida con Espectrometría de Masas
5.
J Anal Toxicol ; 48(1): 75-80, 2024 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-37952092

RESUMEN

A new class of synthetic cannabinoids called OXIZIDs has emerged in recent years. This class consists of compounds with oxindole cores and hydrazide/hydrazone linker moieties and has often been described as being designed to circumvent a Chinese class-wide ban that was effective as of 1 July 2021. However, through hair testing of nightclub attendees in New York City-a high-risk population for recreational drug use-we have evidence suggesting exposures to an OXIZID called BZO-4en-POXIZID (4en-pentyl MDA-19) prior to the effective ban. Through analysis of 6 cm segmented hair samples from attendees collected in 2021, we detected five cases of exposure. Specifically, we detected a cluster of three cases based on hair samples collected on 20 June 2021, and then two additional cases from samples collected on 16 July 2021. Four of these hair samples were long enough to analyze two 6 cm hair segments (representing approximately two 6-month timeframes) and three of four of these cases tested positive for repeated exposure (for an estimated exposure over 6 months prior to hair collection). All cases included young adult females reporting past-year cannabis use but all tested negative for tetrahydrocannabinol exposure. Three cases also reported past-year use of cocaine, ecstasy, and/or ketamine, and four cases tested positive for exposure to cocaine, 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), methamphetamine and/or eutylone. These subjects were exposed to BZO-4en-POXIZID-likely as an adulterant in other drugs, and these cases are among the first documented cases which occurred approximately half a year before the Chinese legislative ban.


Asunto(s)
3,4-Metilenodioxianfetamina , Cocaína , Drogas Ilícitas , Metanfetamina , N-Metil-3,4-metilenodioxianfetamina , Femenino , Adulto Joven , Humanos , Ciudad de Nueva York/epidemiología , Drogas Ilícitas/análisis , N-Metil-3,4-metilenodioxianfetamina/análisis , Metanfetamina/análisis , 3,4-Metilenodioxianfetamina/análisis , Cocaína/análisis
6.
Drug Test Anal ; 16(4): 392-397, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37501581

RESUMEN

The amphetamine-type stimulant methamphetamine exists in two enantiomeric forms, (S)-methamphetamine and (R)-methamphetamine, which are both psychoactive but with the (S)-enantiomer being more potent than the (R)-enantiomer. Illicit methamphetamine encountered in Europe is typically a racemic mixture of both enantiomers and enantiopure (S)-methamphetamine, respectively. However, herein we report two cases with proven enantiopure (R)-methamphetamine consumption with moreover both cases remaining undetected by immunoassay screening. Inconspicuous immunoassay findings can be traced back to a considerably higher sensitivity and concentration-dependent cross-reactivity of the applied drug of abuse assay for the (S)-enantiomer of methamphetamine compared with the (R)-enantiomer, and this limitation should be well known by users of immunoassay drug tests.


Asunto(s)
Metanfetamina , Metanfetamina/análisis , Anfetamina/análisis , Estereoisomerismo , Detección de Abuso de Sustancias , Europa (Continente) , Inmunoensayo
7.
J Forensic Sci ; 69(1): 365-370, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37888147

RESUMEN

A 28-year-old man was admitted dead to the emergency department of the regional hospital. All resuscitation attempts were unsuccessful in this case. Attending officers stated that he was suspected of possessing drugs at the time of arrest and had taken them quickly to cover up. Upon arrival at the hospital, signs of violence were noted all over his body. During the autopsy, two large blue plastic packages were found in the antrum of the stomach. The first was 6.3 × 2.2 cm and had two tight knots, while the second was 7.6 x 1.7 cm and had a single knot. Both packages were irregularly shaped and contained tablet debris that was clearly leaking, as a large amount of gastric juice was present in both packages. A confirmatory forensic toxicology analysis revealed toxic concentrations of methamphetamine in the blood of the dissected case. The patient died of acute methamphetamine intoxication associated with a severe stress condition resulting from violent resistance during arrest.


Asunto(s)
Transporte Intracorporal de Contrabando , Cuerpos Extraños , Metanfetamina , Masculino , Humanos , Adulto , Cuerpos Extraños/complicaciones , Metanfetamina/análisis , Estómago/química , Autopsia
8.
Se Pu ; 41(12): 1141-1148, 2023 Dec.
Artículo en Chino | MEDLINE | ID: mdl-38093545

RESUMEN

Amphetamine-type drugs are synthetic compounds with an amphetamine parent structure. These compounds cause addiction, central nervous system excitation, and hallucinations. The number of drug users worldwide has gradually increased because amphetamine-type drugs can be synthesized in a simple and artificial manner. The current methods for anti-drug screening and toxicant identification are limited by the large quantity and variety of the drug analytes and long detection times. Thus, the development of broad-spectrum, rapid, and high-throughput detection methods is an urgent necessity. In addition, conventional amphetamine-type drug test samples, such as blood and urine, are only suitable for short-term drug identification. Hair has the advantages of easy preservation, stability, and a long detection window, which can compensate for the deficiencies of body-fluid-based test materials. Hair samples can reflect long-term drug use, which is beneficial for tracing drug sources, and has become an important means of providing evidence in court. Because most laboratory instruments are unable to perform the rapid on-site detection of amphetamine-type drugs in hair, establishing a high-throughput, qualitative and quantitative rapid on-site detection method is necessary. In this study, pulsed direct current electrospray ionization (Pulsed-DC-ESI) coupled with mass spectrometry was used for the rapid detection of four amphetamine-type drugs (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, and 3,4-methylenedioxymethamphetamine) in hair. Methanol was used as the extraction solvent, and the grinding method was used for extraction. The pretreatment process included cutting, grinding, and centrifugation. The pretreatment time for each sample was about 10 min. Multiple samples could be processed in batches, greatly improving the efficiency of analysis. Pulsed-DC-ESI is an ambient ionization technology that can be conducted via direct injection without chromatographic separation. The tip of the spray capillary tube was immersed 1 cm below the surface of the sample solution to allow absorption via the capillary effect. When the spray capillary tube contained 1 µL of the sample solution, detection was performed. Pulsed-DC-ESI generates an electrospray at the same frequency as the mass spectrum, thereby avoiding the problem of sample wastage, which often occurs in traditional ESI. The portable mass spectrometer used for analysis is a linear ion trap mass spectrometer. The parameters of Pulsed-DC-ESI, such as the inner diameter of spray capillary tip, spray voltage, and distance between electrode and solution, were optimized based on the mass spectral responses of the amphetamine-type drugs. The optimized ion source conditions included a inner diameter of spray capillary tip of 25 µm, spray voltage of 2 kV, and the distance between electrode and solution of 20 mm. The optimal sample solvent was methanol. The optimized method can achieve simultaneous detection of the four amphetamine-type drugs within 20 s. The linear ranges of amphetamine, methamphetamine, and the two other drugs were 1-25, 1-100, and 1-50 ng/mg, respectively. The limits of detection and quantification of the four drugs in hair were 0.1-0.2 and 1 ng/mg, respectively. All linear correlation coefficients were greater than 0.99, and the average spiked recoveries were 86.6%-114.7%. The intra-day precisions were 4.14%-7.34%, and the inter-day precisions were 3.71%-8.43%. The proposed method was used to screen 2000 samples provided by various testing institutions. A total of five samples were positive for methamphetamine, which is consistent with the results of conventional forensic identification methods. Thus, the developed method can be used for the rapid detection of amphetamine-type drugs.


Asunto(s)
Anfetamina , Metanfetamina , Anfetamina/análisis , Espectrometría de Masa por Ionización de Electrospray , Metanol/análisis , Metanfetamina/análisis , Cabello/química , Solventes/análisis
9.
Rev Neurol ; 77(12): 293-298, 2023 Dec 16.
Artículo en Español | MEDLINE | ID: mdl-38095053

RESUMEN

INTRODUCTION: Chronic non-recreational use of methamphetamine (shabu) is increasing among the Filipino population in Barcelona. The Asian population presents a different stroke pattern, with a higher incidence of haemorrhage, and different vascular risk factors and health behaviours. The objective of this study is to describe the stroke profile and incidence of methamphetamine use in patients of Filipino origin admitted to our centre. PATIENTS AND METHODS: Demographic data, vascular risk factors, clinical data and prognosis were recorded. Methamphetamine exposure was analysed in plasma samples collected on admission, which were then analysed by liquid chromatography-mass spectrometry. RESULTS: Of a total of 6,418 stroke patients, 73 (1.1%) were identified as being of Filipino origin. The mean age was 54.4 ± 12.1 years, 54% were male and the stroke was ischaemic in 64.4% of cases. Arterial hypertension was the main risk factor. Ten (13.7%) patients tested positive for methamphetamine and amphetamine. These results confirm recent substance use prior to the stroke, mostly in men (80%). In patients who were consumers, 60% had a haemorrhagic stroke, with a poor functional prognosis at three months in 55.6% of patients. CONCLUSIONS: In our setting, patients of Filipino ethnicity admitted for stroke related to the consumption of shabu belonged a younger age bracket, with a lower prevalence of vascular risk factors and a predominance of the haemorrhagic subtype. Methamphetamine testing in Filipino stroke patients is recommended due to the high prevalence of methamphetamine use in our country.


TITLE: Perfil clínico y abuso de metanfetamina no recreativa (shabú) entre los pacientes con ictus en la población filipina.Introducción. En la población filipina de Barcelona está aumentando el consumo crónico no recreativo de metanfetaminas (shabú). La población asiática presenta un patrón de ictus diferente, con mayor incidencia de hemorragias, y diferentes factores de riesgo vascular y conductas de salud. El objetivo es describir el perfil de ictus e incidencia de consumo de metanfetaminas en pacientes de origen filipino ingresados en nuestro centro. Pacientes y métodos. Se registraron datos demográficos, factores de riesgo vascular, datos clínicos y pronóstico. Se analizó la exposición a metanfetamina en muestras de plasma recogidas en el ingreso, que se analizaron por cromatografía líquida-espectrometría de masas. Resultados. Del total de 6.418 pacientes con ictus, se identificó a 73 pacientes filipinos (1,1%). La edad media era de 54,4 ± 12,1 años, el 54% eran hombres y el ictus era isquémico en el 64,4%. La hipertensión arterial fue el principal factor de riesgo. Diez (13,7%) pacientes dieron positivo a metanfetamina y anfetamina. Estos resultados confirman un consumo reciente de sustancias previo al ictus, principalmente en hombres (80%). En pacientes consumidores, un 60% presentaba un ictus hemorrágico, con mal pronóstico funcional a tres meses en el 55,6% de los pacientes. Conclusiones. En nuestro medio, los pacientes de etnia filipina ingresados por ictus en relación con consumo de shabú presentaron un perfil de edad más joven, con menor prevalencia de factores de riesgo vascular y predominio del subtipo hemorrágico. Se recomienda la determinación de metanfetamina en los pacientes filipinos con ictus debido a la alta prevalencia del consumo de metanfetamina en nuestro país.


Asunto(s)
Trastornos Relacionados con Anfetaminas , Metanfetamina , Accidente Cerebrovascular , Humanos , Masculino , Adulto , Persona de Mediana Edad , Anciano , Femenino , Filipinas/epidemiología , Metanfetamina/efectos adversos , Metanfetamina/análisis , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Trastornos Relacionados con Anfetaminas/complicaciones , Trastornos Relacionados con Anfetaminas/epidemiología , Anfetamina
10.
Anal Methods ; 15(46): 6482-6491, 2023 11 30.
Artículo en Inglés | MEDLINE | ID: mdl-37987503

RESUMEN

This study was focused on the development of a sensitive, reliable, and efficient extraction procedure for the determination of amphetamine and methamphetamine utilized in the adulteration of creatine sports supplements. The separation and detection of the analytes were conducted using the gas chromatography-flame ionization detection method. In this study, the analytes were extracted from a supplement powder into a proper solvent by sonication. Then, the extract was mixed with butyl chloroformate to obtain their butylated derivatives and then concentrated by a dispersive liquid-liquid microextraction procedure. The method was performed in a short time. Under optimized extraction conditions, a linear range of 2.01-500 ng g-1 was obtained by a coefficient of determination ≥0.996. Low detection (0.22 ng g-1 and 0.61 ng g-1 for amphetamine and methamphetamine, respectively) and quantification (0.73 ng g-1 and 2.01 ng g-1 for amphetamine and methamphetamine, respectively) limits, good precision (relative standard deviations ≤8.2%), and high extraction recoveries (79% and 86% for amphetamine and methamphetamine, respectively) were achieved. The usefulness of the method in the analysis of the target compounds was confirmed by studying the matrix effect and analysis of the analytes in different real samples.


Asunto(s)
Microextracción en Fase Líquida , Metanfetamina , Metanfetamina/análisis , Anfetamina/análisis , Creatina/análisis , Microextracción en Fase Líquida/métodos , Cromatografía de Gases/métodos
11.
Anal Methods ; 15(42): 5692-5699, 2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-37861716

RESUMEN

Colloidal gold immunoassay is the most widely used method in the field of drug detection. However, this method often has poor quantitative identification ability and low analytical sensitivity, which is not suitable for the analysis of hair poisoning ingredients. In order to solve these limitations, we developed an immunochromatographic test strip for simultaneously screening multiple drugs in this study. This hand-held test strip used fluorescent nanoparticles loaded with lanthanide chelates as the signal carrier of fluorescence reading, and conducted quantitative testing of various drugs based on the competitive immune reaction between the analyte and antigen. Under the optimal conditions, the competition curves of morphine (MOP), methamphetamine (MET) and ketamine (KET) were obtained on a single band. The detection limit (LOD) of this analytical method was 100-1000 times lower than that of colloidal gold test strips. The detection limits of MOP, MET and KET were 0.06 ng mL-1, 0.1 ng mL-1 and 1.0 ng mL-1, respectively. No cross-reaction was observed when morphine, methamphetamine and ketamine were tested simultaneously with this method. And 184 hair samples were tested simultaneously, and the detected amount was very close to the results of LC-MS. The immunochromatographic strip showed good stability in repeated tests, and the coefficient of variation was less than 15%. Fluorescence immunochromatography strips and handheld strip readers have the characteristics of portability, speed, ease of operation and high sensitivity, and may become powerful tools for screening drug abuse in hair in forensic medicine.


Asunto(s)
Ketamina , Elementos de la Serie de los Lantanoides , Metanfetamina , Morfina/análisis , Límite de Detección , Metanfetamina/análisis , Cromatografía de Afinidad/métodos , Oro Coloide/química , Cabello/química
12.
Sci Total Environ ; 905: 166910, 2023 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-37689196

RESUMEN

Wastewater-based epidemiology (WBE) has emerged as an effective method for monitoring a community's health status and lifestyle. In recent years, enantiomeric profiling has shown promise as a tool for tracing the sources of abused drugs through WBE. This study investigated amphetamine (AMP) and methamphetamine (METH) consumption in South Korea using enantiomeric analysis of untreated wastewater samples collected from 27 wastewater-treatment plants (WWTPs). Both AMP and METH were detected, with the predominant detection of S-(+)-METH indicating widespread illegal use of METH, which is primarily produced by a clandestine synthesis procedure that involves the reduction of ephedrine/pseudoephedrine. Most AMP/METH ratios in the samples were consistent with the expected METH excretion profile, indicating that the presence of AMP was primarily due to METH metabolism. However, R-(-) AMP was detected in 18.5 % and 25.9 % of wastewater samples in winter and spring, respectively, and the high AMP/METH ratio (>0.27) indicated potential AMP abuse. By differentiating between the sources of AMP and METH in wastewater, enantiomeric analysis could help authorities to target and address specific drug-abuse issues affecting the population more effectively.


Asunto(s)
Metanfetamina , Contaminantes Químicos del Agua , Metanfetamina/análisis , Aguas Residuales , Detección de Abuso de Sustancias/métodos , Anfetamina/análisis , República de Corea , Contaminantes Químicos del Agua/análisis
13.
Water Res ; 244: 120452, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37604019

RESUMEN

Drug consumption in prisons is a concern for the safety of incarcerated people and staff. Typically, drug use prevalence in prisons is estimated through urinalysis and intelligence operations, which can be intrusive and stressful. An alternative approach, wastewater-based epidemiology (WBE), was used in this study to estimate the consumption of licit and illicit drugs for the entire population of a prison in Australia. Wastewater samples were collected from March to December 2020, covering periods of no restrictions and periods when prison access was restricted to prevent the transmission of COVID-19. Target biomarkers were analysed by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). The average consumption of common illicit drugs (MDMA, methamphetamine and cocaine) over the sampling period in the prison (0.5 - 4.5 mg/1000 people/day) was two to three orders of magnitude lower than in the community population (254 - 1000 mg/1000 people/day). Comparison of WBE estimates against pharmacy dispensing data suggested potential illicit buprenorphine consumption at the prison. Methamphetamine and buprenorphine use decreased when no visitors were allowed (18% - 72% decrease for methamphetamine; about half decrease for buprenorphine) and increased once these restrictions were eased (22% - 39% increase for methamphetamine; 44% - 67% increase for buprenorphine). The changes in drug use may be attributed in part to a reduction of drug trafficking into the prison from visitors or non-essential staffs and in part to the reduced contribution of urine from staff who used toilets within the prison. This study provided useful information on the scale of illicit drug use and extra-medical use of licit drugs in prison, and its changes under different security conditions.


Asunto(s)
Buprenorfina , COVID-19 , Drogas Ilícitas , Metanfetamina , Trastornos Relacionados con Sustancias , Contaminantes Químicos del Agua , Humanos , Drogas Ilícitas/análisis , Prisiones , Aguas Residuales , Cromatografía Liquida , Detección de Abuso de Sustancias/métodos , Espectrometría de Masas en Tándem , COVID-19/epidemiología , Trastornos Relacionados con Sustancias/epidemiología , Metanfetamina/análisis , Contaminantes Químicos del Agua/análisis , Buprenorfina/análisis
14.
J Forensic Sci ; 68(6): 2093-2102, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37650474

RESUMEN

Cocaine and methamphetamine remain highly abused drugs in the United States due to their euphoric effects. This study examines classical stimulant casework, defined as cases positive for methamphetamine and/or cocaine, received by the Toxicology Laboratory and the Drug Analysis Laboratory at the Dallas County Southwestern Institute of Forensic Sciences from local law enforcement agencies and/or the Office of the Medical Examiner (OME) between January 1, 2017, and December 31, 2022. Methamphetamine positivity increased from 10.4% to 20.3% in the Toxicology Laboratory over the 6 years, whereas cocaine positivity remained relatively stable at approximately 17%. Similarly, in the Drug Analysis Laboratory, the methamphetamine positivity rate changed from 24.8% to 33.2%, whereas cocaine identification remained stable at approximately 20%. Blood concentrations of methamphetamine in OME cases ranged from 10.1-42,740.0 ng/mL while they were lower in DWI casework ranging from 10.2-2385.0 ng/mL. The blood concentration trends of cocaine were similar to methamphetamine, with OME casework ranging higher (10.0-24,501.0 ng/mL) than DWI casework (10.2-371.6 ng/mL). Polydrug use was evident for both methamphetamine and cocaine in postmortem cases, and the top three most frequently co-occurring drug/drug class were opioids/opiates, cannabinoids, and ethanol. The results from this study aid in the understanding of historical usage trends of cocaine and methamphetamine in Dallas County and how those trends have changed over time as newer stimulant drugs have emerged.


Asunto(s)
Estimulantes del Sistema Nervioso Central , Cocaína , Metanfetamina , Trastornos Relacionados con Sustancias , Humanos , Estados Unidos , Estudios Retrospectivos , Cocaína/análisis , Metanfetamina/análisis , Trastornos Relacionados con Sustancias/epidemiología
15.
Chemosphere ; 339: 139668, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37517667

RESUMEN

Residues of illicit drugs are frequently detected in wastewater, but data on their removal efficiency by wastewater treatment plants (WWTPs) and the ecological risks to the aquatic environment are lacking in this study. The research evaluates the residues, mass load, drug removal efficiency, and risk assessment of illicit drugs in WWTPs and aquatic environments (lakes) in Xinjiang, China. Initially, the concentration (incidence) and mass load of 10 selected illicit drugs were analyzed through wastewater analysis. The detected substances included methamphetamine (METH), morphine (MOR), 3,4-methylenedioxy methamphetamine (MDMA), methadone (MTD), cocaine (COC), benzoylecgonine (BE), ketamine (KET), and codeine (COD), with concentrations ranging from 0.11 ± 0.01 ng/L (methadone) to 48.26 ± 25.05 ng/L (morphine). Notably, morphine (59.74 ± 5.82 g/day) and methamphetamine (41.81 ± 4.91 g/day) contributed significantly to the WWTPs. Next, the drug removal efficiency by different sewage treatment processes was ranked as follows: Anaerobic-Oxic (A/O) combined Membrane Bio-Reactor (MBR) treatment process > Oxidation ditch treatment process > Anaerobic-Anoxic-Oxic (A2/O) treatment process > Anaerobic-Anoxic-Oxic combined Membrane Bio-Reactor treatment process. Finally, the research reviewed the concentration and toxicity assessments of these substances in the aquatic environment (lakes). The results indicated that Lake1 presented a medium risk level concerning the impact of illicit drugs on the aquatic environment, whereas the other lakes exhibited a low risk level. As a result, it is recommended to conduct long-term monitoring and source analysis of illicit drugs, specifically in Lake1, for further investigation. In conclusion, to enhance the understanding of the effects of illicit drugs on the environment, future research should expand the list of target analytes.


Asunto(s)
Drogas Ilícitas , Metanfetamina , Contaminantes Químicos del Agua , Purificación del Agua , Aguas Residuales , Eliminación de Residuos Líquidos/métodos , Drogas Ilícitas/análisis , Ríos , Contaminantes Químicos del Agua/análisis , Metanfetamina/análisis , Purificación del Agua/métodos , Medición de Riesgo , Derivados de la Morfina/análisis , China
16.
J Forensic Sci ; 68(4): 1268-1276, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37149745

RESUMEN

Bone samples are valuable for examining the cause of death and circumstance leading up to death when body fluids are not available for forensic toxicological analysis. Examined were heat-induced changes in methamphetamine and amphetamine concentrations in femurs removed from methamphetamine-injected mice to determine if the burned bones could be used for toxicology testing. The femurs were heated at 100°C, 300°C, or 500°C for 10 or 30 min. The tissue structure of the heated femurs was preserved at 100°C for 30 min but was destructed at higher temperatures. Methamphetamine and amphetamine were detected in femurs heated at 100°C for 10 min, 100°C for 30 min, and 300°C for 10 min (with methamphetamine and amphetamine concentrations ranging from 0.36 to 35 µg/g and 0.54 to 47 µg/g, respectively). Methamphetamine and amphetamine were detectable when heated above their decomposition temperature as a result of limited heat transfer do to protection provide by the femoral muscle. Thus, the bone could be a useful analytical sample in cases of burn-related deaths, where it is difficult to collect body fluids.


Asunto(s)
Metanfetamina , Animales , Ratones , Anfetamina/análisis , Fémur/química , Calor , Metanfetamina/análisis , Temperatura
17.
Sci Total Environ ; 889: 164310, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37211103

RESUMEN

Understanding the consumption patterns of substances with abuse potential in the population is critical in combating drug crimes in the region. In recent years, wastewater-based drug monitoring has become a complementary tool worldwide. This study aimed to use this approach to understand the long-term consumption patterns of abuse potential substances in Xinjiang, China (2021-2022) and to provide more detailed and practical information on the current system. High-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was employed to quantify the levels of abuse potential substances in wastewater. Subsequently, the detection rate and contribution rate of the drug concentrations were evaluated through analysis. Eleven of abuse potential substances were detected in this study. The influent concentrations ranged from (0.48 ng/L) to 133.41 ng/L, with dextrorphan having the highest concentration. The highest detection frequency rates were for morphine (82 %), dextrorphan (59 %), 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid (43 %), methamphetamine (36 %), and tramadol (24 %). According to a study on wastewater treatment plants (WWTPs) removal efficiency, compared to the total removal efficiency in 2021, the total removal efficiency of WWTP1, WWTP3, and WWTP4 increased in 2022, while WWTP2 decreased slightly, and WWTP5 did not change significantly. Upon examination of the use of 18 selected analytes, it was determined that methadone, 3,4-methylenedioxy methamphetamine, ketamine, and cocaine were the primary substances of abuse in the Xinjiang region. This study identified significant abuse substances in Xinjiang and identified research priorities. Future studies should consider expanding the study site to obtain a comprehensive understanding of the consumption patterns of these substances in Xinjiang.


Asunto(s)
Metanfetamina , Contaminantes Químicos del Agua , Aguas Residuales , Espectrometría de Masas en Tándem , Dextrorfano/análisis , Contaminantes Químicos del Agua/análisis , Metanfetamina/análisis , China
18.
J Anal Toxicol ; 47(4): 346-352, 2023 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-36611270

RESUMEN

In forensic toxicology, hair has become a hot biological material for drug testing due to its wider detection window and noninvasive sampling process compared to traditional liquid biological materials (e.g., blood and urine). However, hair as a matrix differs from body fluids, as it is not as easily aliquoted for analysis. Nevertheless, pretreatment methods for hair detection have gradually improved from the first chemical methods, such as alkali digestion and acid hydrolysis, to now include the physical method of pulverization and further improvements beyond "pulverization" protocols. In a previous study, we updated and developed a "micropulverized extraction" method. In the present study, our aim was to gain a more complete understanding of the "micropulverized extraction" method by comparing pulverization temperature and hair particle size, as these two factors are known to influence the effectiveness of sample processing. The analytes we selected were those commonly encountered in traditional drug abuse cases: (±)-methamphetamine, (±)-amphetamine, morphine, 6-acetylmorphine, cocaine, benzoylecgonine, (--)-∆9-tetrahydrocannabinol, ketamine, (±)-norketamine and (±)-3,4-methylenedioxymethamphetamine. The analysis method was liquid chromatography-tandem mass spectrometry.


Asunto(s)
Drogas Ilícitas , Metanfetamina , N-Metil-3,4-metilenodioxianfetamina , Drogas Ilícitas/análisis , Anfetamina/análisis , Metanfetamina/análisis , N-Metil-3,4-metilenodioxianfetamina/análisis , Detección de Abuso de Sustancias/métodos , Cabello/química
19.
Talanta ; 255: 124208, 2023 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-36628903

RESUMEN

Methamphetamine (MA) is a synthetic psychoactive drug which is consumed both licitly and illicitly. In some countries it is prescribed for attention-deficit and hyperactivity disorder, and short-term treatment of obesity. More often though, it is abused for its psychostimulant properties. Unfortunately, the spread and abuse of this synthetic drug have increased globally, being reported as the most widely consumed synthetic psychoactive drug in the world in 2019. Attempting to overcome the shortcomings of the currently used on-site methods for MA detection in suspected cargos, the present study explores the potential of electrochemical identification of MA by means of square wave voltammetry on disposable graphite screen-printed electrodes. Hence, the analytical characterization of the method was evaluated under optimal conditions exhibiting a linear range between 50 µM and 2.5 mM MA, a LOD of 16.7 µM, a LOQ of 50.0 µM and a sensitivity of 5.3 µA mM-1. Interestingly, two zones in the potential window were identified for the detection of MA, depending on its concentration in solution. Furthermore, the oxidative pathway of MA was elucidated employing liquid chromatography - mass spectrometry to understand the change in the electrochemical profile. Thereafter, the selectivity of the method towards MA in mixtures with other drugs of abuse as well as common adulterants/cutting agents was evaluated. Finally, the described method was employed for the analysis of MA in confiscated samples and compared with forensic methods, displaying its potential as a fast and easy-to-use method for on-site analysis.


Asunto(s)
Estimulantes del Sistema Nervioso Central , Metanfetamina , Metanfetamina/análisis , Cromatografía Liquida , Medicina Legal , Electrodos , Psicotrópicos/análisis
20.
J Anal Toxicol ; 47(2): 197-205, 2023 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-35900095

RESUMEN

Amphetamines (AMPs) in hair were investigated with thousands of workplace testing head and body hair samples collected and analyzed over 10 years and tabulated by year. All samples were washed by a published extensive method prior to confirmation by liquid chromatography-mass spectrometry-mass spectrometry. Presented are concentrations of parent methamphetamine (METH), 3,4-methylenedioxymethamphetamine (MDMA) and methylenedioxyamphetamine as metabolite and AMP as metabolite and without the presence of parent drug. Some differences in METH concentrations from year to year were significant, and some ratios of metabolite to parent drug for both METH and MDMA also varied significantly. While rates of METH use may not have changed significantly, some aspects of the drugs ingested as demonstrated by hair analysis varied over the 10-year period.


Asunto(s)
Metanfetamina , N-Metil-3,4-metilenodioxianfetamina , N-Metil-3,4-metilenodioxianfetamina/análisis , Detección de Abuso de Sustancias/métodos , Anfetaminas/análisis , Metanfetamina/análisis , Cabello/química , Lugar de Trabajo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...