Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.935
Filtrar
1.
Jt Dis Relat Surg ; 35(2): 439-442, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38727126

RESUMEN

Tension band wiring (TBW) is one of the most commonly used fixation techniques to fix olecranon osteotomies. Hardware prominence has been the most commonly reported complication of TBW. However, distal migration of Kirschner (K)-wire after TBW fixation for olecranon osteotomy has not been reported. In this case report, we presented distal migration of K-wire detected nine months after initial surgery in a 46-year-old male patient. The patient was operated on for an intraarticular distal humerus fracture using an olecranon osteotomy. The osteotomy was fixed with TBW fixation. The patient missed routine follow-ups and presented to the outpatient clinic with a complaint of skin irritation at the elbow nine months after the surgery. On radiological examination, distal migration of one K-wire was detected. The K-wire was surgically removed without any complication. Physicians should be aware of possible complications of TBW and remove fixation after fracture union to avoid unexpected complications.


Asunto(s)
Hilos Ortopédicos , Migración de Cuerpo Extraño , Olécranon , Osteotomía , Humanos , Hilos Ortopédicos/efectos adversos , Masculino , Persona de Mediana Edad , Olécranon/lesiones , Olécranon/cirugía , Olécranon/diagnóstico por imagen , Osteotomía/efectos adversos , Osteotomía/métodos , Osteotomía/instrumentación , Migración de Cuerpo Extraño/cirugía , Migración de Cuerpo Extraño/diagnóstico por imagen , Migración de Cuerpo Extraño/etiología , Fracturas del Húmero/cirugía , Fracturas del Húmero/diagnóstico por imagen , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Remoción de Dispositivos/métodos , Articulación del Codo/cirugía , Articulación del Codo/diagnóstico por imagen , Fracturas Intraarticulares/cirugía , Fracturas Intraarticulares/diagnóstico por imagen
2.
J Med Case Rep ; 18(1): 234, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38698425

RESUMEN

BACKGROUND: Nexplanon implants are a common hormonal contraceptive modality. Though rare, these devices can embolize into the injured wall of the basilic vein, through the right heart, and finally wedge itself into a pulmonary artery. With adherence to the arterial wall over time, it becomes less amenable to endovascular retrieval. Patients may present with symptoms mimicking a pulmonary embolism, or without any symptoms at all. In asymptomatic cases, endovascular retrieval and/or surgery is required when patients wish to begin having children prior to biological inactivity. The current literature showed as little as nine case reports detailing lung tissue removal in the aim of reversing a patient's implanted contraceptive device. CASE PRESENTATION: A 22-year-old asymptomatic active-duty Caucasian female presented for elective outpatient Nexplanon removal. The suspicion of possible implant migration arose when it was discovered to be non-palpable in her left arm. After plain film x-rays failed to localize the implant, a chest x-ray and follow-up Computed Tomography (CT) scan revealed that the Nexplanon had migrated to a distal branch of the left pulmonary artery. Due to the patient's strong desires to begin having children, the decision was made for removal. Initial endovascular retrieval failed due to Nexplanon encapsulation within the arterial wall. Ultimately, the patient underwent a left video-assisted thoracoscopic surgery (VATS) for exploration and left lower lobe basilar S7-9 segmentectomy, which successfully removed the Nexplanon. CONCLUSIONS: Implanted contraceptive devices can rarely result in migration to the pulmonary vasculature. These radiopaque devices are detectable on imaging studies if patients and clinicians are unable to palpate them. An endovascular approach should be considered first to spare lung tissue and avoid chest-wall incisions, but can be complicated by encapsulation and adherence to adjacent tissue. A VATS procedure with single-lung ventilation via a double-lumen endotracheal tube allows surgeons to safely operate on an immobilized lung while anesthesiologists facilitate single-lung ventilation. This patient's case details the uncommon phenomenon of Nexplanon migration, and the exceedingly rare treatment resolution of lung resection to remove an embolized device.


Asunto(s)
Desogestrel , Remoción de Dispositivos , Migración de Cuerpo Extraño , Humanos , Femenino , Remoción de Dispositivos/métodos , Desogestrel/administración & dosificación , Migración de Cuerpo Extraño/cirugía , Migración de Cuerpo Extraño/diagnóstico por imagen , Adulto Joven , Anticonceptivos Femeninos/administración & dosificación , Implantes de Medicamentos , Arteria Pulmonar/cirugía , Arteria Pulmonar/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Embolia Pulmonar/etiología , Resultado del Tratamiento , Neumonectomía
4.
JACC Cardiovasc Interv ; 17(8): 1060-1062, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38573255
5.
J Investig Med High Impact Case Rep ; 12: 23247096241238527, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38646799

RESUMEN

Biliary endoprostheses are widely used in the treatment of biliary lithiasis, malignant and benign strictures, and occasionally in long-lasting biliary fistulas. They can be placed endoscopically during endoscopic retrograde cholangiopancreatography and radiologically (percutaneous) when the endoscopic route is not feasible. Complications associated with the endoscopic placement of biliary endoprostheses are well described in the literature, with migration being the most common. Intestinal obstruction is a rare complication associated with the migration of these devices. There are no reports in the literature of this complication occurring after percutaneous placement. We present a case of a patient who arrived at the emergency department with ileal obstruction secondary to the migration and concurrent embedding of a covered stent placed radiologically to treat a biliary leak after surgery. The patient underwent diagnostic laparoscopic and ileal resection, revealing a lithiasic concretion at the tip of the stent, causing the small bowel obstruction.


Asunto(s)
Migración de Cuerpo Extraño , Obstrucción Intestinal , Stents , Humanos , Stents/efectos adversos , Obstrucción Intestinal/etiología , Obstrucción Intestinal/cirugía , Migración de Cuerpo Extraño/cirugía , Migración de Cuerpo Extraño/diagnóstico por imagen , Migración de Cuerpo Extraño/complicaciones , Masculino , Colangiopancreatografia Retrógrada Endoscópica , Femenino , Anciano , Laparoscopía , Intestino Delgado
6.
Abdom Radiol (NY) ; 49(5): 1646-1652, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38592493

RESUMEN

PURPOSE: To evaluate the efficacy and safety of a novel technique for removal of migrated esophageal stent (MES) under fluoroscopy. METHODS: From January 2009 to April 2023, 793 patients with a dysphagia score of 3-4 underwent esophageal stenting at our center, and 25 patients (mean age: 70.06 years old; male/female: 15/10) underwent stent removal using "loop method" under fluoroscopy. The primary outcomes were technical success and complications. The secondary outcomes were procedure time, radiation exposure, biochemical indicators [white blood cell (WBC), hemoglobin (Hb), platelet (PLT), albumin (ALB), alanine transaminase (ALT), total bilirubin (TB), urea nitrogen (UN) and C-reactive protein] of pre- and post-treatment at 2 weeks. RESULTS: Technical success was 100% without major complications. The mean procedure time was (39.44 ± 9.28) minutes, which showed no statistical significance between benign (n = 5) and malignant (n = 20) group [(42.40 ± 8.85) vs (38.71 ± 9.46) mins, p > 0.05]. The mean radiation exposure was (332.88 ± 261.47) mGy, which showed no statistical significance between benign and malignant group [(360.74 ± 231.43) vs (325.92 ± 273.54) mGy, p > 0.05]. Pre- and post-procedure Hb [(114.46 ± 11.96) vs. (117.57 ± 13.12) g/L] and ALB [(42.26 ± 3.39) vs. (44.12 ± 3.77) g/L] showed significant difference (p < 0.05), while WBC, PLT, CRP, and ALT showed no significance (p > 0.05). CONCLUSION: Fluoroscopy-guided "Loop method" for MES removal is an effective and safe alternative technique.


Asunto(s)
Remoción de Dispositivos , Stents , Humanos , Femenino , Fluoroscopía , Masculino , Anciano , Remoción de Dispositivos/métodos , Migración de Cuerpo Extraño/diagnóstico por imagen , Estudios Retrospectivos , Persona de Mediana Edad , Trastornos de Deglución/etiología , Radiografía Intervencional/métodos , Anciano de 80 o más Años
7.
J Med Case Rep ; 18(1): 184, 2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38539178

RESUMEN

BACKGROUND: Fractures of the clavicle are common injuries, which often require reduction and internal fixation. Although Kirschner pins have been commonly used to treat these fractures with good results, migration of these devices may result in severe internal lesions. CASE PRESENTATION: We report herein the case of 61-year-old man, who presented for intrapulmonary migration of a Kirschner pin, 25 years after closed reduction and fixation of a clavicle fracture. CONCLUSION: Migration of an osteosynthesis pin can be lethal. Patients with osteosynthesis pins, should have a regular follow, until the removal of the wires.


Asunto(s)
Migración de Cuerpo Extraño , Fracturas Óseas , Masculino , Humanos , Persona de Mediana Edad , Clavícula/diagnóstico por imagen , Clavícula/cirugía , Clavícula/lesiones , Migración de Cuerpo Extraño/diagnóstico por imagen , Migración de Cuerpo Extraño/cirugía , Fijación Interna de Fracturas , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Hilos Ortopédicos/efectos adversos
8.
J Cardiothorac Surg ; 19(1): 101, 2024 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-38374106

RESUMEN

BACKGROUND: Acupuncture, a traditional Chinese medical treatment, has been gaining popularity over the years. However, it also presents certain risks. We report a case of a patient who discovered a foreign body in their lung several years after undergoing acupuncture. CASE PRESENTATION: A middle-aged woman presented to our hospital with chest pain. An X-ray revealed a needle-like foreign body in the middle lobe of her right lung. The patient had previously undergone acupuncture treatment for local pain in her lower back and lower extremities many years prior. Based on the imaging findings and her medical history, we hypothesized that the foreign body in her lung was a result of a dislodged acupuncture needle. Through preoperative 3-dimensional reconstruction and indocyanine green localization, we were able to locate the foreign body in the lateral segment of the right middle lobe. We successfully removed the foreign body via wedge resection, and the patient made a smooth recovery post-surgery. CONCLUSION: Acupuncturists and surgeons should remain vigilant about the potential risks associated with acupuncture.


Asunto(s)
Terapia por Acupuntura , Cuerpos Extraños , Migración de Cuerpo Extraño , Humanos , Persona de Mediana Edad , Femenino , Agujas/efectos adversos , Terapia por Acupuntura/efectos adversos , Cuerpos Extraños/diagnóstico por imagen , Cuerpos Extraños/etiología , Cuerpos Extraños/cirugía , Radiografía , Dolor en el Pecho , Migración de Cuerpo Extraño/diagnóstico por imagen , Migración de Cuerpo Extraño/etiología
10.
Vasc Endovascular Surg ; 58(5): 559-566, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38196287

RESUMEN

INTRODUCTION AND IMPORTANCE: Long-term mechanical complications after inferior vena cava (IVC) filter placement include embedded or tilted filters, erosion of the vena cava, filter thrombosis. In the setting of caval thrombosis, patients may subsequently develop venous hypertension and post-thrombotic syndrome (PTS). Here we present three unique cases of IVC filter complications and surgical management. CASE PRESENTATION: A 30-year-old female presented with acute abdominal pain, revealing a duodenal perforation caused by an IVC filter eroding into her duodenum. A 42-year-old female with an IVC filter in place for 20 years due to a prior pulmonary embolism underwent laser-assisted retrieval of the filter due to concerns of caval adherence. A 48-year-old male with a history of DVT, venous stasis ulcer, and an IVC filter presented for filter retrieval. CLINICAL FINDINGS AND INVESTIGATIONS: The surgical techniques described in this report include complicated IVC filter retrieval, performed in cases of filter complications including migration, fracture, duodenal perforation and IVC thrombosis resulting in PTS. One case, requiring open retrieval, is explained and the surgical technique is provided. There are images and videos of these procedures to enrich the learning experience. INTERVENTION AND OUTCOMES: The surgical techniques described in this report include complicated inferior vena cava filter retrieval, performed in cases of filter complications including migration, fracture, duodenal perforation and IVC thrombosis. One case, requiring open retrieval, is explained and the surgical technique is provided. There are images and videos of these procedures to enrich the learning experience. RELEVANCE AND IMPACT: Endovascular retrieval of long-term complicated IVC filters is challenging, but it can be a safely performed in many patients. However, open surgery may be necessary in selected patients.


Asunto(s)
Remoción de Dispositivos , Migración de Cuerpo Extraño , Filtros de Vena Cava , Vena Cava Inferior , Trombosis de la Vena , Humanos , Filtros de Vena Cava/efectos adversos , Masculino , Persona de Mediana Edad , Femenino , Adulto , Resultado del Tratamiento , Migración de Cuerpo Extraño/etiología , Migración de Cuerpo Extraño/diagnóstico por imagen , Migración de Cuerpo Extraño/cirugía , Vena Cava Inferior/diagnóstico por imagen , Vena Cava Inferior/lesiones , Vena Cava Inferior/cirugía , Trombosis de la Vena/etiología , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/terapia , Perforación Intestinal/etiología , Perforación Intestinal/cirugía , Perforación Intestinal/diagnóstico por imagen , Implantación de Prótesis/instrumentación , Implantación de Prótesis/efectos adversos , Factores de Tiempo , Diseño de Prótesis , Flebografía
11.
Vasc Endovascular Surg ; 58(5): 567-570, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38240584

RESUMEN

Coil migration during endovascular embolization is a complication that can result in thromboembolic occlusion leading to potentially large infarcts if not removed. Microsnares are commonly used to remove migrated coils. Current techniques, however, struggle in cases where the microsnare is unable to loop over and secure a free end of the coil. We present a case in which a microsnare combined with a microwire successfully removed a migrated coil in a patient with a bleeding hepatic pseudoaneurysm post-embolization. This technique proved beneficial when traditional methods were insufficient, especially in small vessels or coil packs that cannot be snared. The synergy of the microsnare and microwire technique presents a promising solution for challenging migrated coil retrievals.


Asunto(s)
Aneurisma Falso , Remoción de Dispositivos , Embolización Terapéutica , Migración de Cuerpo Extraño , Humanos , Migración de Cuerpo Extraño/etiología , Migración de Cuerpo Extraño/diagnóstico por imagen , Migración de Cuerpo Extraño/terapia , Migración de Cuerpo Extraño/cirugía , Embolización Terapéutica/instrumentación , Resultado del Tratamiento , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/terapia , Aneurisma Falso/etiología , Arteria Hepática/diagnóstico por imagen , Masculino , Hemorragia/etiología , Hemorragia/terapia , Anciano , Diseño de Equipo , Femenino
14.
Childs Nerv Syst ; 40(2): 587-591, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37855877

RESUMEN

Intracardiac migration is a rare complication of ventriculoperitoneal shunt insertion. Only 15 cases have been reported, 7 of which were paediatric cases, treated with techniques including interventional radiography, open thoracotomies and direct extraction through the initial shunt incision. The authors report the youngest case of intracardiac shunt migration complicated by significant coiling and knotting within the cardiac chambers and pulmonary vasculature. Migration likely began when the SVC was pierced during initial shunt placement and progressed due to negative intrathoracic pressure. Extrusion was achieved combining thoracoscopic endoscopy, interventional fluoroscopy screening and a posterolateral neck incision with uncoiling of the shunt via a Seldinger guide wire. This offered a minimally invasive solution with rapid post-operative recovery.


Asunto(s)
Migración de Cuerpo Extraño , Derivación Ventriculoperitoneal , Humanos , Niño , Derivación Ventriculoperitoneal/efectos adversos , Derivación Ventriculoperitoneal/métodos , Catéteres/efectos adversos , Cateterismo , Migración de Cuerpo Extraño/diagnóstico por imagen , Migración de Cuerpo Extraño/etiología , Migración de Cuerpo Extraño/cirugía
15.
Childs Nerv Syst ; 40(1): 19-25, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37857859

RESUMEN

OBJECTIVE: The incidence of scrotal migration of a ventriculoperitoneal shunt (VPS) catheter is rare and may lead to life-threatening visceral complications. Management requires prompt removal of the migrated portion of the shunt and closure of the scrotal sac. We report an interesting case of a young child who presented with asymptomatic unilateral swelling of his scrotum secondary to a migrated VPS catheter. A repeat X-ray prior to his surgery to remove the migrated catheter showed that the entire length of the distal VPS catheter was back in the peritoneal cavity. In view of this unusual phenomenon, the case is discussed in corroboration with published literature. METHODS AND RESULTS: A systematic search of publications in the English language is performed in PubMed and Google Scholar. Our findings show that there are 49 reported cases (including our patient) of scrotal migration of shunt catheters in patients less than 18 years old. There is only 1 other case of spontaneous resolution of shunt catheter from the scrotum. Favoured management of choice is repositioning the distal shunt catheter back into the peritoneal cavity and herniotomy in the same setting, if possible. Overall, the literature suggests this is a shunt-related complication that has a good prognosis if intervention is timely. CONCLUSION: Scrotal migration of a VPS catheter is a rare but potentially life-threatening complication in children. Our case report highlights the role of updated preoperative imaging and the need for consistent long-term shunt surveillance in children.


Asunto(s)
Migración de Cuerpo Extraño , Hidrocefalia , Masculino , Niño , Humanos , Adolescente , Escroto/cirugía , Derivación Ventriculoperitoneal/efectos adversos , Peritoneo , Remisión Espontánea , Hidrocefalia/cirugía , Catéteres/efectos adversos , Migración de Cuerpo Extraño/diagnóstico por imagen , Migración de Cuerpo Extraño/etiología , Migración de Cuerpo Extraño/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...