1.
J Laryngol Otol ; 137(2): 231-236, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34895370

RESUMEN

OBJECTIVE: Serious device-related complications for hypoglossal nerve stimulators are rare, but surgeons should implement a prompt and systematic approach to quickly troubleshoot a non-functioning device. METHOD: Records were queried at a single academic tertiary referral centre between January 2019 and June 2021. RESULTS: The authors present four cases of non-functioning hypoglossal nerve stimulator devices: one case in which migration of the stimulation lead required a revision implantation, one in which the implantable pulse generator was found to be non-functional intra-operatively, one case of an intramuscular sensory lead tract causing pain and one case of implantable pulse generator failure that was probably triggered by implantable cardiac device discharge. In this study, computed tomography imaging was critical to the diagnosis for the first and third cases. CONCLUSION: Given the limited complication reporting available for hypoglossal nerve stimulators, these cases highlight management and unique imaging findings. The authors present an algorithm to work-up non-functioning hypoglossal nerve stimulator devices.


Asunto(s)
Terapia por Estimulación Eléctrica , Apnea Obstructiva del Sueño , Humanos , Terapia por Estimulación Eléctrica/efectos adversos , Terapia por Estimulación Eléctrica/métodos , Apnea Obstructiva del Sueño/terapia , Nervio Hipogloso , Neuroestimuladores Implantables/efectos adversos , Tomografía
2.
Laryngoscope ; 131(11): 2616-2624, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34626128

RESUMEN

OBJECTIVES/HYPOTHESIS: To provide the ADHERE registry Upper Airway Stimulation (UAS) outcomes update, including analyses grouped by body mass index (BMI) and therapy discomfort. STUDY DESIGN: Prospective observational study. METHODS: ADHERE captures UAS outcomes including apnea-hypopnea index (AHI), Epworth sleepiness scale (ESS), therapy usage, patient satisfaction, clinician assessment, and safety over a 1-year period. BMI ≤32 kg/m2 (BMI32 ) and 32 < BMI ≤35 kg/m2 (BMI35 ) group outcomes were examined. RESULTS: One thousand eight hundred forty-nine patients enrolled in ADHERE, 1,019 reached final visit, 843 completed the visit. Significant changes in AHI (-20.9, P < .0001) and ESS (- 4.4, P < .0001) were demonstrated. Mean therapy usage was 5.6 ± 2.2 hr/day. Significant therapy use difference was present in patients with reported discomfort versus no discomfort (4.9 ± 2.5 vs. 5.7 ± 2.1 hr/day, P = .01). Patients with discomfort had higher final visit mean AHI versus without discomfort (18.9 ± 18.5 vs. 13.5 ± 13.7 events/hr, P = .01). Changes in AHI and ESS were not significantly different. Serious adverse events reported in 2.3% of patients. Device revision rate was 1.9%. Surgical success was less likely in BMI35 versus BMI32 patients (59.8% vs. 72.2%, P = .02). There was a significant therapy use difference: 5.8 ± 2.0 hr/day in BMI32 versus 5.2 ± 2.2 hr/day in BMI35 (P = .028). CONCLUSIONS: Data from ADHERE demonstrate high efficacy rates for UAS. Although surgical response rate differs between BMI32 and BMI35 patient groups, the AHI and ESS reduction is similar. Discomfort affects therapy adherence and efficacy. Thus, proper therapy settings adjustment to ensure comfort is imperative to improve outcomes. LEVEL OF EVIDENCE: 4 Laryngoscope, 131:2616-2624, 2021.


Asunto(s)
Índice de Masa Corporal , Terapia por Estimulación Eléctrica/efectos adversos , Neuroestimuladores Implantables/efectos adversos , Cooperación del Paciente/estadística & datos numéricos , Apnea Obstructiva del Sueño/terapia , Anciano , Terapia por Estimulación Eléctrica/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sistema de Registros/estadística & datos numéricos , Índice de Severidad de la Enfermedad , Apnea Obstructiva del Sueño/diagnóstico , Resultado del Tratamiento
3.
World Neurosurg ; 156: e72-e76, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34500098

RESUMEN

OBJECTIVE: We examined the role of intrawound vancomycin powder as prophylaxis against postoperative surgical site infection (SSI) after spinal cord stimulator (SCS) implantation. METHODS: We performed a retrospective analysis of 153 consecutive patients who had undergone permanent SCS implantation surgery via open laminectomy between 2014 and 2020. We queried the patients' medical records for patient age, sex, relevant medical history, and whether intrawound vancomycin had been administered. We compared the rates of SSI (primary outcome) and seroma (secondary outcome) within 3 months after surgery between the vancomycin and no-vancomycin groups. Finally, we conducted multivariable logistic regression analyses to identify independent predictors of postoperative SSI or seroma. RESULTS: Of the 153 patients, 59% were women, and the average age was 65.4 years. Overall, 3 patients (2%) had developed an SSI: 2 (methicillin-resistant Staphylococcus aureus, Klebsiella) in the vancomycin group and 1 (methicillin-sensitive Staphylococcus aureus) in the no-vancomycin group. This difference in SSI rate between the 2 groups was insignificant (P = 0.73). Three seromas, all in the no-vancomycin group, accounted for a statistically significant difference in seroma formation between the 2 groups (P = 0.04). Multivariate logistic regression failed to identify any perioperative characteristics as independent predictors of postoperative SSI or seroma. CONCLUSIONS: Our experience suggests open laminectomy for SCS implantation surgery can be performed with a low postoperative SSI rate, with or without the use of powdered vancomycin. We found no evidence suggesting that the use of powdered vancomycin is unsafe or related to postoperative seroma formation. We failed to draw any definitive conclusions regarding its efficacy, despite referencing the largest single case series of SCS implantation to date.


Asunto(s)
Neuroestimuladores Implantables , Laminectomía/métodos , Estimulación de la Médula Espinal/métodos , Enfermedades de la Columna Vertebral/terapia , Infección de la Herida Quirúrgica/prevención & control , Vancomicina/administración & dosificación , Anciano , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Humanos , Neuroestimuladores Implantables/efectos adversos , Laminectomía/efectos adversos , Laminectomía/instrumentación , Masculino , Persona de Mediana Edad , Polvos , Estudios Retrospectivos , Estimulación de la Médula Espinal/efectos adversos , Estimulación de la Médula Espinal/instrumentación , Enfermedades de la Columna Vertebral/diagnóstico , Infección de la Herida Quirúrgica/diagnóstico
4.
Clin Geriatr Med ; 37(3): 429-444, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34210448

RESUMEN

Undiagnosed and untreated obstructive sleep apnea (OSA) is associated with health comorbidities and negatively affects quality of life. Alternative treatments should be considered in patients who are unable to tolerate or benefit from positive airway pressure treatment. When properly indicated, positional devices, oral appliances, airway surgery, and hypoglossal nerve stimulation have been shown to be effective in treating OSA. Hypoglossal nerve stimulation is a successful second-line treatment with low associated morbidity and complication rate.


Asunto(s)
Terapia por Estimulación Eléctrica/métodos , Neuroestimuladores Implantables/efectos adversos , Apnea Obstructiva del Sueño/cirugía , Anciano , Humanos , Nervio Hipogloso/fisiología , Avance Mandibular , Nervio Frénico/fisiología , Calidad de Vida , Resultado del Tratamiento
5.
Parkinsonism Relat Disord ; 88: 60-61, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-34139434

RESUMEN

We report two cases of granuloma that occurred around an implantable pulse generator (IPG) for deep brain stimulation. Both cases showed no signs of infection and disappeared after moving the IPG and removing the granulation. If a noninfectious mass is formed, the relocation of IPG may improve it.


Asunto(s)
Estimulación Encefálica Profunda/efectos adversos , Granuloma de Cuerpo Extraño/etiología , Granuloma de Cuerpo Extraño/terapia , Neuroestimuladores Implantables/efectos adversos , Trastornos del Movimiento/terapia , Humanos
6.
Urology ; 157: 71-78, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34048826

RESUMEN

OBJECTIVES: To evaluate the safety and efficacy of the eCoin - a nickel-sized, primary battery-powered, neuromodulation device for the treatment of urgency urinary incontinence which is implanted in the lower leg in a 20-minute procedure under local anesthesia. A feasibility clinical trial was conducted and the results after 1 year of treatment with the eCoin are presented. METHODS: A total of 46 participants with refractory urgency urinary incontinence were included in this prospective, single-arm, open-label study. This study was conducted at 7 sites in the United States and New Zealand. Participants in this study were implanted with the eCoin in the lower leg over the tibial nerve and activated after 4 weeks. Bladder diary data and validated quality-of-life instruments, collected at 3, 6, and 12 months' post-activation, were compared to baseline values. RESULTS: Responders were defined as those who had a ≥50% reduction in reported episodes of urgency urinary incontinence. At 12 months', 65% of participants were considered responders with 26% of participants achieving complete continence. The median number of urgency urinary incontinence episodes per day decreased from 4.2 at baseline to 1.7 at 12 months'. Seventy percent of participants reported feeling "better", "much better", or "very much better" on the Likert 7-point maximum scale. One participant experienced a related serious adverse event. CONCLUSION: The eCoin is a safe and effective treatment for urgency urinary incontinence associated with overactive bladder syndrome, with significant reduction or complete resolution of symptoms and no significant safety concerns.


Asunto(s)
Terapia por Estimulación Eléctrica/instrumentación , Neuroestimuladores Implantables , Vejiga Urinaria Hiperactiva/complicaciones , Incontinencia Urinaria de Urgencia/terapia , Terapia por Estimulación Eléctrica/efectos adversos , Diseño de Equipo/efectos adversos , Estudios de Factibilidad , Femenino , Humanos , Neuroestimuladores Implantables/efectos adversos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Implantación de Prótesis , Calidad de Vida , Autoinforme , Nervio Tibial , Factores de Tiempo , Resultado del Tratamiento , Incontinencia Urinaria de Urgencia/etiología
7.
Urology ; 156: 78-84, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34015396

RESUMEN

OBJECTIVES: To apply a human factors approach, the study of interactions between humans and complex systems, to investigate patient preparedness, satisfaction, and perceived usability with sacral neuromodulation (SNM) and develop interventions aimed at improving patient experience. MATERIALS AND METHODS: Ten patients with overactive bladder undergoing staged SNM were observed, and data including pre-operative preparedness, satisfaction, perceived usability and barriers impacting patient experience were collected. Interventions were developed and an additional ten patients were observed. All patients were English-speaking and at least 18 years of age. RESULTS: Pre-intervention patients had difficulty understanding the risks of the procedure, did not know what to expect post-operatively and were unsatisfied with pre-operative materials. Interventions included: A pre-procedure educational video and informational sheet, detailed discharge instructions; and a nursing inservice. Pre-operative preparedness (Stage I: U = 100, z = 3.785, P = .000; Stage II: U = 80, z = 2.864, P = .003), post-operative satisfaction (Stage I: U = 100, z = 3.788, P = .000; Stage II: U = 77.5, z = 2.665, P = .006.) and perceptions of usability (Stage I: U = 77.00, z = 2.056, P = .043.; Stage II: U = 80.50, z = 2.308, P = .019) increased significantly after the intervention. CONCLUSION: Our observations highlight the value of implementing a human factors approach to identify and mitigate barriers impacting patient experiences with SNM. Through the implementation of systems-level interventions (ie, interventions that impact the non-clinical aspects of surgery such as patient and/or staff education), significant improvements can be made.


Asunto(s)
Neuroestimuladores Implantables , Educación del Paciente como Asunto , Satisfacción del Paciente , Vejiga Urinaria Hiperactiva/terapia , Adulto , Anciano , Anciano de 80 o más Años , Educación en Enfermería , Terapia por Estimulación Eléctrica , Ergonomía/métodos , Femenino , Humanos , Neuroestimuladores Implantables/efectos adversos , Capacitación en Servicio , Masculino , Persona de Mediana Edad , Alta del Paciente , Complicaciones Posoperatorias/etiología , Periodo Posoperatorio , Periodo Preoperatorio , Estudios Prospectivos , Implantación de Prótesis/efectos adversos , Sacro
8.
Parkinsonism Relat Disord ; 88: 129-135, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-34011446

RESUMEN

As the number of patients implanted with deep brain stimulation systems increases, coexistence with cardiac implantable electronic devices (CIEDs) poses questions about safety. We systematically reviewed the literature on coexisting DBS and CIED. Eighteen reports of 34 patients were included. Device-device interactions were reported in 6 patients. Sources of complications were extensively reviewed and cautious measures which could be considered as part of a standard checklist for careful consideration are suggested.


Asunto(s)
Desfibriladores Implantables , Cardiopatías/terapia , Neuroestimuladores Implantables , Trastornos del Movimiento/terapia , Marcapaso Artificial , Seguridad del Paciente , Comorbilidad , Desfibriladores Implantables/efectos adversos , Desfibriladores Implantables/normas , Cardiopatías/epidemiología , Humanos , Neuroestimuladores Implantables/efectos adversos , Neuroestimuladores Implantables/normas , Trastornos del Movimiento/epidemiología , Marcapaso Artificial/efectos adversos , Marcapaso Artificial/normas
9.
Laryngoscope ; 131(9): 2148-2153, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33864394

RESUMEN

OBJECTIVES/HYPOTHESIS: Hypoglossal nerve stimulation (HNS) has gained increasing interest for the treatment of patients with obstructive sleep apnea (OSA). Drug-induced sleep endoscopy (DISE) can both exclude improper airway collapse patterns and visualize airway changes under stimulation. Stimulation outcome effects depend on the impulse voltage and electric field resulting from the electrode configuration of the implanted device. The effects of various combinations of voltage and electric field on DISE airway patterns in contrast to awake endoscopy are unknown. STUDY DESIGN: Cohort study. METHODS: During therapy adjustment about 6 months after implantation, patients underwent a DISE and awake endoscopy with 100% and 125% of functional voltage in three typical electrode configurations (+ - +, o - o, - - -). All videos were analyzed by two separate persons for the opening of the airway at velum, tongue base, and epiglottis level. RESULTS: Thirty patients showed typical demographic data. The opening effects were visible in all patients, but there were changes between different electrode configurations. Several demographic or therapeutic aspects such as obesity, OSA severity, or prior soft palate surgery were associated with changes arising from different electrode configurations, but none resulted in a consistently better airway opening. CONCLUSIONS: In patients with poor results during the therapy adjustment, electric configuration changes can improve airway patency-an independent variable from increasing voltage. As these effects can only be seen in awake endoscopy or DISE, both endoscopies with live stimulation may be considered in cases with insufficient improvement in apnea-hypopnea index after initiation of HNS therapy. LEVEL OF EVIDENCE: Prospective case series; level 4. Laryngoscope, 131:2148-2153, 2021.


Asunto(s)
Remodelación de las Vías Aéreas (Respiratorias)/fisiología , Electrodos/efectos adversos , Neuroestimuladores Implantables/efectos adversos , Apnea Obstructiva del Sueño/terapia , Estudios de Cohortes , Electrodos Implantados/estadística & datos numéricos , Endoscopía/métodos , Epiglotis/fisiopatología , Estudios de Evaluación como Asunto , Femenino , Humanos , Nervio Hipogloso/fisiopatología , Masculino , Persona de Mediana Edad , Obesidad/complicaciones , Paladar Blando/fisiopatología , Valor Predictivo de las Pruebas , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Apnea Obstructiva del Sueño/diagnóstico , Apnea Obstructiva del Sueño/fisiopatología , Lengua/fisiopatología
10.
Lancet ; 397(10284): 1545-1553, 2021 04 24.
Artículo en Inglés | MEDLINE | ID: mdl-33894832

RESUMEN

BACKGROUND: Long-term loss of arm function after ischaemic stroke is common and might be improved by vagus nerve stimulation paired with rehabilitation. We aimed to determine whether this strategy is a safe and effective treatment for improving arm function after stroke. METHODS: In this pivotal, randomised, triple-blind, sham-controlled trial, done in 19 stroke rehabilitation services in the UK and the USA, participants with moderate-to-severe arm weakness, at least 9 months after ischaemic stroke, were randomly assigned (1:1) to either rehabilitation paired with active vagus nerve stimulation (VNS group) or rehabilitation paired with sham stimulation (control group). Randomisation was done by ResearchPoint Global (Austin, TX, USA) using SAS PROC PLAN (SAS Institute Software, Cary, NC, USA), with stratification by region (USA vs UK), age (≤30 years vs >30 years), and baseline Fugl-Meyer Assessment-Upper Extremity (FMA-UE) score (20-35 vs 36-50). Participants, outcomes assessors, and treating therapists were masked to group assignment. All participants were implanted with a vagus nerve stimulation device. The VNS group received 0·8 mA, 100 µs, 30 Hz stimulation pulses, lasting 0·5 s. The control group received 0 mA pulses. Participants received 6 weeks of in-clinic therapy (three times per week; total of 18 sessions) followed by a home exercise programme. The primary outcome was the change in impairment measured by the FMA-UE score on the first day after completion of in-clinic therapy. FMA-UE response rates were also assessed at 90 days after in-clinic therapy (secondary endpoint). All analyses were by intention to treat. This trial is registered at ClinicalTrials.gov, NCT03131960. FINDINGS: Between Oct 2, 2017, and Sept 12, 2019, 108 participants were randomly assigned to treatment (53 to the VNS group and 55 to the control group). 106 completed the study (one patient for each group did not complete the study). On the first day after completion of in-clinic therapy, the mean FMA-UE score increased by 5·0 points (SD 4·4) in the VNS group and by 2·4 points (3·8) in the control group (between group difference 2·6, 95% CI 1·0-4·2, p=0·0014). 90 days after in-clinic therapy, a clinically meaningful response on the FMA-UE score was achieved in 23 (47%) of 53 patients in the VNS group versus 13 (24%) of 55 patients in the control group (between group difference 24%, 6-41; p=0·0098). There was one serious adverse event related to surgery (vocal cord paresis) in the control group. INTERPRETATION: Vagus nerve stimulation paired with rehabilitation is a novel potential treatment option for people with long-term moderate-to-severe arm impairment after ischaemic stroke. FUNDING: MicroTransponder.


Asunto(s)
Neuroestimuladores Implantables/efectos adversos , Accidente Cerebrovascular Isquémico/complicaciones , Rehabilitación de Accidente Cerebrovascular/métodos , Extremidad Superior/fisiopatología , Estimulación del Nervio Vago/instrumentación , Anciano , Estudios de Casos y Controles , Terapia Combinada/métodos , Terapia por Ejercicio/métodos , Femenino , Humanos , Accidente Cerebrovascular Isquémico/rehabilitación , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud , Paresia/etiología , Recuperación de la Función/fisiología , Resultado del Tratamiento , Parálisis de los Pliegues Vocales/epidemiología
11.
Clin Neurol Neurosurg ; 203: 106577, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33662743

RESUMEN

Deep brain stimulation (DBS) has evolved into an approved and efficacious treatment for movement, obsessive-compulsive, and epilepsy disorders that are refractory to medical therapy, with current investigation into other disease conditions. However, there are unintentional and intentional sources of external electromagnetic interference (EMI) that can lead to either malfunctioning or damaged DBS devices, as well as injury to human tissue. Comprehensive studies and guidelines on such topics in the medical literature are scarce. Herein, we review the principles behind EMI, as well as the various potential sources of interference, both unintentional (e.g. stray EMI fields) and intentional (e.g. MRI scans, "brainjacking"). Additionally, we employ the Manufacturer and User Device Facility Experience (MAUDE) database to assess real-world instances of EMI (e.g., airport body scanners, magnetic resonance imaging (MRI), and electrosurgery) affecting DBS devices commonly implanted in the United States (US).


Asunto(s)
Estimulación Encefálica Profunda/instrumentación , Campos Electromagnéticos/efectos adversos , Electrónica , Neuroestimuladores Implantables/efectos adversos , Humanos
12.
Neurology ; 96(17): 799-804, 2021 04 27.
Artículo en Inglés | MEDLINE | ID: mdl-33727407

RESUMEN

Neurostimulation provides a new dimension in the treatment of neurologic disorders. For patients with drug-resistant epilepsy, the Responsive Neurostimulation (RNS) System (NeuroPace, Inc.) provides treatment of seizures with a closed-loop device that continuously records brain activity and provides stimulation designed to reduce seizure frequency over time. The presence of a chronic implanted device that can provide an electrographic record of neural activity provides great opportunities for treatment of seizure disorders and neuroscience research. However, our experience with this device indicates that a number of ethical and clinical challenges arise, and these issues may be applicable to neurotechnology developed for other disease states in the future. We present clinical scenarios based on cases from our center that present clinical or ethical dilemmas. The dilemmas revolve around 4 core themes: (1) electroclinical correlation and dissociation; (2) patient concerns about device capabilities; (3) clinician opportunities and burdens; and (4) data ownership and access. Developing a framework for understanding these issues will be critical as closed-loop neuromodulation is applied to a growing range of neuropsychiatric disorders.


Asunto(s)
Epilepsia Refractaria/terapia , Epilepsias Parciales/terapia , Epilepsia/terapia , Convulsiones/terapia , Encéfalo/cirugía , Estimulación Encefálica Profunda/métodos , Electrodos Implantados/efectos adversos , Electroencefalografía/métodos , Humanos , Neuroestimuladores Implantables/efectos adversos , Masculino , Persona de Mediana Edad
13.
Ear Nose Throat J ; 100(4): 233-236, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33729895

RESUMEN

Bonebridge (BB) is the first active implantation system for bone conduction that is placed fully under the skin. Experience suggests that BB is characterized by low incidence of postoperative complications. This case report presents a rare case of a 16-year-old girl with incidence of emphysema occurring over the implant 1 year after operation. We performed a computed tomography scan that showed pockets of gas above the floating mass transducer so we provided the revision surgery and sealed the artificial opening with fat from the earlobe and fibrin glue. Since that time, no air has collected in the retroauricular area and the implant has been fully functional.


Asunto(s)
Enfermedades del Oído/etiología , Enfisema/etiología , Neuroestimuladores Implantables/efectos adversos , Complicaciones Posoperatorias/etiología , Implantación de Prótesis/efectos adversos , Adolescente , Conducción Ósea , Femenino , Audífonos/efectos adversos , Pérdida Auditiva Conductiva/cirugía , Humanos , Ilustración Médica
14.
Curr Opin Infect Dis ; 34(3): 238-244, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33741795

RESUMEN

PURPOSE OF REVIEW: To review recent data on the epidemiology, microbiology, diagnosis, and management of central nervous system (CNS) infections associated with neurologic devices. RECENT FINDINGS: The increasing use of implanted neurologic devices has led to an increase in associated infections. Cerebrospinal fluid (CSF) inflammation may be present after a neurosurgical procedure, complicating the diagnosis of CNS infection. Newer biomarkers such as CSF lactate and procalcitonin show promise in differentiating infection from other causes of CSF inflammation. Molecular diagnostic tests including next-generation or metagenomic sequencing may be superior to culture in identifying pathogens causing healthcare-associated ventriculitis and meningitis. SUMMARY: Neurologic device infections are serious, often life-threatening complications. Rapid recognition and initiation of antibiotics are critical in decreasing morbidity. Device removal is usually required for cure.


Asunto(s)
Infecciones del Sistema Nervioso Central/microbiología , Derivaciones del Líquido Cefalorraquídeo/efectos adversos , Drenaje/efectos adversos , Procedimientos Neuroquirúrgicos/efectos adversos , Procedimientos Neuroquirúrgicos/instrumentación , Infecciones del Sistema Nervioso Central/etiología , Drenaje/instrumentación , Humanos , Neuroestimuladores Implantables/efectos adversos
15.
Ann Clin Transl Neurol ; 8(3): 613-622, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33596331

RESUMEN

OBJECTIVE: Deep brain stimulation (DBS) improves motor symptoms in Parkinson's disease (PD), but it can also disrupt verbal fluency with significant costs to quality of life. The current study investigated how variability of bilateral active electrode coordinates along the superior/inferior, anterior/posterior, and lateral/medial axes in the subthalamic nucleus (STN) or the globus pallidus interna (GPi) contribute to changes in verbal fluency. We predicted that electrode location in the left hemisphere would be linked to changes in fluency, especially in the STN. METHODS: Forty PD participants treated with bilateral DBS targeting STN (n = 23) or GPi (n = 17) completed verbal fluency testing in their optimally treated state before and after DBS therapy. Normalized atlas coordinates from left and right active electrode positions along superior/inferior, anterior/posterior, and lateral/medial axes were used to predict changes in fluency postoperatively, separately for patients with STN and GPi targets. RESULTS: Consistent with prior studies, fluency significantly declined pre- to postsurgery (in both DBS targets). In STN-DBS patients, electrode position along the inferior to superior axis in the left STN was a significant predictor of fluency changes; relatively more superior left active electrode was associated with the largest fluency declines in STN. Electrode coordinates in right STN or GPi (left or right) did not predict fluency changes. INTERPRETATION: We discuss these findings in light of putative mechanisms and potential clinical impact.


Asunto(s)
Disfunción Cognitiva/etiología , Estimulación Encefálica Profunda , Globo Pálido , Neuroestimuladores Implantables , Enfermedad de Parkinson/tratamiento farmacológico , Complicaciones Posoperatorias , Núcleo Subtalámico , Anciano , Estimulación Encefálica Profunda/efectos adversos , Femenino , Lateralidad Funcional , Humanos , Neuroestimuladores Implantables/efectos adversos , Masculino , Persona de Mediana Edad , Pruebas Neuropsicológicas
16.
N Engl J Med ; 384(6): 521-532, 2021 02 11.
Artículo en Inglés | MEDLINE | ID: mdl-33567192

RESUMEN

BACKGROUND: Bilateral vestibular hypofunction is associated with chronic disequilibrium, postural instability, and unsteady gait owing to failure of vestibular reflexes that stabilize the eyes, head, and body. A vestibular implant may be effective in alleviating symptoms. METHODS: Persons who had had ototoxic (7 participants) or idiopathic (1 participant) bilateral vestibular hypofunction for 2 to 23 years underwent unilateral implantation of a prosthesis that electrically stimulates the three semicircular canal branches of the vestibular nerve. Clinical outcomes included the score on the Bruininks-Oseretsky Test of Motor Proficiency balance subtest (range, 0 to 36, with higher scores indicating better balance), time to failure on the modified Romberg test (range, 0 to 30 seconds), score on the Dynamic Gait Index (range, 0 to 24, with higher scores indicating better gait performance), time needed to complete the Timed Up and Go test, gait speed, pure-tone auditory detection thresholds, speech discrimination scores, and quality of life. We compared participants' results at baseline (before implantation) with those at 6 months (8 participants) and at 1 year (6 participants) with the device set in its usual treatment mode (varying stimulus pulse rate and amplitude to represent rotational head motion) and in a placebo mode (holding pulse rate and amplitude constant). RESULTS: The median scores at baseline and at 6 months on the Bruininks-Oseretsky test were 17.5 and 21.0, respectively (median within-participant difference, 5.5 points; 95% confidence interval [CI], 0 to 10.0); the median times on the modified Romberg test were 3.6 seconds and 8.3 seconds (difference, 5.1; 95% CI, 1.5 to 27.6); the median scores on the Dynamic Gait Index were 12.5 and 22.5 (difference, 10.5 points; 95% CI, 1.5 to 12.0); the median times on the Timed Up and Go test were 11.0 seconds and 8.7 seconds (difference, 2.3; 95% CI, -1.7 to 5.0); and the median speeds on the gait-speed test were 1.03 m per second and 1.10 m per second (difference, 0.13; 95% CI, -0.25 to 0.30). Placebo-mode testing confirmed that improvements were due to treatment-mode stimulation. Among the 6 participants who were also assessed at 1 year, the median within-participant changes from baseline to 1 year were generally consistent with results at 6 months. Implantation caused ipsilateral hearing loss, with the air-conducted pure-tone average detection threshold at 6 months increasing by 3 to 16 dB in 5 participants and by 74 to 104 dB in 3 participants. Changes in participant-reported disability and quality of life paralleled changes in posture and gait. CONCLUSIONS: Six months and 1 year after unilateral implantation of a vestibular prosthesis for bilateral vestibular hypofunction, measures of posture, gait, and quality of life were generally in the direction of improvement from baseline, but hearing was reduced in the ear with the implant in all but 1 participant. (Funded by the National Institutes of Health and others; ClinicalTrials.gov number, NCT02725463.).


Asunto(s)
Vestibulopatía Bilateral/cirugía , Marcha/fisiología , Pérdida Auditiva/etiología , Neuroestimuladores Implantables , Equilibrio Postural/fisiología , Calidad de Vida , Vestíbulo del Laberinto/cirugía , Anciano , Vestibulopatía Bilateral/inducido químicamente , Vestibulopatía Bilateral/complicaciones , Mareo/etiología , Femenino , Trastornos Neurológicos de la Marcha/etiología , Humanos , Neuroestimuladores Implantables/efectos adversos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios Prospectivos , Canales Semicirculares/inervación , Nervio Vestibular/efectos de los fármacos
18.
Trials ; 22(1): 87, 2021 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-33494781

RESUMEN

BACKGROUND: Spinal cord stimulation (SCS) is an effective method to treat neuropathic pain; however, it is challenging to compare different stimulation modalities in an individual patient, and thus, it is largely unknown which of the many available SCS modalities is most effective. Specifically, electrodes leading out through the skin would have to be consecutively connected to different, incompatible SCS devices and be tested over a time period of several weeks or even months. The risk of wound infections for such a study would be unacceptably high and blinding of the trial difficult. The PARS-trial seizes the capacity of a new type of wireless SCS device, which enables a blinded and systematic intra-patient comparison of different SCS modalities over extended time periods and without increasing wound infection rates. METHODS: The PARS-trial is designed as a double-blinded, randomized, and placebo-controlled multi-center crossover study. It will compare the clinical effectiveness of the three most relevant SCS paradigms in individual patients. The trial will recruit 60 patients suffering from intractable neuropathic pain of the lower extremities, who have been considered for SCS therapy and were already implanted with a wireless SCS device prior to study participation. Over a time period of 35 days, patients will be treated consecutively with three different SCS paradigms ("burst," "1 kHz," and "1.499 kHz") and placebo stimulation. Each SCS paradigm will be applied for 5 days with a washout period of 70 h between stimulation cycles. The primary endpoint of the study is the level of pain self-assessment on the visual analogue scale after 5 days of SCS. Secondary, exploratory endpoints include self-assessment of pain quality (as determined by painDETECT questionnaire), quality of life (as determined by Quality of Life EQ-5D-5L questionnaire), anxiety perception (as determined by the Hospital Anxiety and Depression Scale), and physical restriction (as determined by the Oswestry Disability Index). DISCUSSION: Combining paresthesia-free SCS modalities with wireless SCS offers a unique opportunity for a blinded and systematic comparison of different SCS modalities in individual patients. This trial will advance our understanding of the clinical effectiveness of the most relevant SCS paradigms. TRIAL REGISTRATION: German Clinical Trials Register, DRKS00018929 . Registered on 14 January 2020.


Asunto(s)
Dolor Crónico/terapia , Neuralgia/terapia , Estimulación de la Médula Espinal/métodos , Adulto , Dolor Crónico/diagnóstico , Estudios Cruzados , Autoevaluación Diagnóstica , Método Doble Ciego , Femenino , Humanos , Neuroestimuladores Implantables/efectos adversos , Masculino , Estudios Multicéntricos como Asunto , Neuralgia/diagnóstico , Dimensión del Dolor , Calidad de Vida , Ensayos Clínicos Controlados Aleatorios como Asunto , Estimulación de la Médula Espinal/efectos adversos , Estimulación de la Médula Espinal/instrumentación , Resultado del Tratamiento , Tecnología Inalámbrica/instrumentación
19.
Laryngoscope ; 131(4): E1375-E1379, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-32865831

RESUMEN

OBJECTIVES/HYPOTHESIS: Selective upper airway stimulation (sUAS) is a well-established treatment option for obstructive sleep apnea (OSA). This study aimed to determine if there are benefits in performing a home sleep test (HST) to evaluate postoperative sUAS effectiveness after patient acclimatization compared to the generally used polysomnography (PSG) titration, as measured by long-term follow-up outcomes. STUDY DESIGN: Retrospective comparative cohort analysis. METHODS: We conducted an analysis of consecutive patients at our center who had completed a 6-month follow-up (month 6 [M6]) and recorded data from M6, month 12 (M12), and month 24 (M24). After device activation, we performed an HST with the patient's stimulation settings, and measured the apnea-hypopnea index (AHI), Epworth Sleepiness Scale (ESS), and device usage. These values were compared to patients who had undergone PSG-based device titration. RESULTS: Baseline values of the initial 131 patients show high ESS and moderate OSA. At the 2-month time point of the HST, nearly half of the patients (46.2%) reached an AHI ≤15/hr, and approximately a fifth (19.2%) reached <5/hr. The PSG and HST groups differed in median ESS at M24, but no other differences were observed for ESS at M6 and M12. Both groups showed similar AHI, oxygen desaturation, and usage hours per week. CONCLUSIONS: Adjusting therapy by using the HST technique after device activation and acclimatization has clinical and economic advantages. These advantages are contingent on several conditions being met when deviating from the standard device protocol, including precise communication with the referring sleep medicine physicians, especially their role in helping with long-term follow-up. LEVEL OF EVIDENCE: 4 Laryngoscope, 131:E1375-E1379, 2021.


Asunto(s)
Terapia por Estimulación Eléctrica/instrumentación , Nervio Hipogloso/cirugía , Neuroestimuladores Implantables/estadística & datos numéricos , Apnea Obstructiva del Sueño/terapia , Femenino , Estudios de Seguimiento , Humanos , Nervio Hipogloso/fisiopatología , Neuroestimuladores Implantables/efectos adversos , Laringe/fisiopatología , Masculino , Persona de Mediana Edad , Cooperación del Paciente/estadística & datos numéricos , Polisomnografía/métodos , Polisomnografía/estadística & datos numéricos , Respiración con Presión Positiva/métodos , Respiración con Presión Positiva/estadística & datos numéricos , Periodo Posoperatorio , Estudios Retrospectivos , Sueño/fisiología , Apnea Obstructiva del Sueño/fisiopatología , Tráquea/fisiopatología , Resultado del Tratamiento