1.
JAMA Otolaryngol Head Neck Surg ; 147(4): 336-342, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-33475683

RESUMEN

Importance: During the novel coronavirus disease 2019 pandemic, telehealth has become a vital component of health care delivery. For otolaryngology evaluations, examination of the ear and oropharynx is important but difficult to achieve remotely. Objective: To assess the feasibility of patient use of low-cost digital videoscopes and smartphones for examination of the ear and oropharynx. Design, Setting, and Participants: A prospective quality improvement study was conducted in an academic adult otolaryngology clinic including 23 patients who presented for an in-person appointment and owned a smartphone device. The study was conducted from July 1 to 15, 2020. Interventions: Participants were asked to capture pictures and videos of their ear canals and oropharynx with digital videoscopes and their smartphones under real-time guidance over a telehealth platform. They were then surveyed about their experience. Main Outcomes and Measures: The primary outcomes were ratings by health care clinicians and a blinded otolaryngologist reviewer of image acceptability. Secondary outcomes included participant time to image acquisition and willingness to purchase digital videoscopes for telehealth use. Results: Of the 23 participants included, 14 were women (61%); mean age was 50 years (range, 21 to 80 years). Of the images obtained using the digital otoscope ear examination, 95% were considered acceptable by the health care clinicians and 91% were considered acceptable by the blinded reviewer; 16 participants (70%) reported that the otoscope was easy to use. The mean time to acquire images for both ears was 114 seconds (95% CI, 84-145 seconds). Twenty-one participants (91%) were willing to pay for a digital otoscope for telehealth use. For the oropharyngeal examination, a greater proportion of smartphone video examinations were considered acceptable by clinicians (63% acceptability) and the blinded reviewer (55%) compared with the digital endoscope (clinicians, 40%; blinded reviewer, 14%). The mean time required for the oropharyngeal examination smartphone video capture was shorter at 35 seconds compared with both the digital endoscope (difference, -27 seconds; 95% CI, -7 to -47 seconds) and smartphone photo capture (difference, -53 seconds; 95% CI, -20 to -87 seconds). Conclusions and Relevance: Digital otoscopes and smartphones apparently can facilitate remote head and neck physical examination in telehealth. Digital otoscopes were useful for ear examinations, and smartphone videos appeared to be the most useful for oropharyngeal examinations. Further studies are required to determine specific diagnostic capabilities in various telehealth practice settings.


Asunto(s)
Otolaringología/economía , Otolaringología/instrumentación , Consulta Remota/métodos , Teléfono Inteligente , Grabación en Video , Adulto , Anciano , Anciano de 80 o más Años , Conducto Auditivo Externo/patología , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Visita a Consultorio Médico , Orofaringe/patología , Otolaringología/métodos , Otoscopios/economía , Aceptación de la Atención de Salud , Satisfacción del Paciente , Proyectos Piloto , Estudios Prospectivos , Adulto Joven
3.
Anal Chem ; 86(20): 10454-60, 2014 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-25226556

RESUMEN

A common motif in otolaryngology is the lack of certainty regarding diagnosis for middle ear conditions, resulting in many patients being overtreated under the worst-case assumption. Although pneumatic otoscopy and adjunctive tests offer additional information, white light otoscopy has been the main tool for diagnosis of external auditory canal and middle ear pathologies for over a century. In middle ear pathologies, the inability to avail high-resolution structural and/or molecular imaging is particularly glaring, leading to a complicated and erratic decision analysis. Here, we propose a novel multiwavelength fluorescence-based video-rate imaging strategy that combines readily available optical elements and software components to create a novel otoscopic device. This modified otoscope enables low-cost, detailed and objective diagnosis of common middle ear pathological conditions. Using the detection of congenital cholesteatoma as a specific example, we demonstrate the feasibility of fluorescence imaging to differentiate this proliferative lesion from uninvolved middle ear tissue based on the characteristic autofluorescence signals. Availability of real-time, wide-field chemical information should enable more complete removal of cholesteatoma, allowing for better hearing preservation and substantially reducing the well-documented risks, costs and psychological effects of repeated surgical procedures.


Asunto(s)
Diagnóstico por Imagen/instrumentación , Enfermedades del Oído/diagnóstico , Oído Medio/patología , Fluorescencia , Otoscopios/normas , Otoscopía/métodos , Colesteatoma/congénito , Colesteatoma/diagnóstico , Humanos , Otoscopios/economía