Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54.576
Filtrar
1.
J Biomed Opt ; 29(Suppl 3): S33302, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38707651

RESUMEN

Significance: Cerebral oximeters have the potential to detect abnormal cerebral blood oxygenation to allow for early intervention. However, current commercial systems have two major limitations: (1) spatial coverage of only the frontal region, assuming that surgery-related hemodynamic effects are global and (2) susceptibility to extracerebral signal contamination inherent to continuous-wave near-infrared spectroscopy (NIRS). Aim: This work aimed to assess the feasibility of a high-density, time-resolved (tr) NIRS device (Kernel Flow) to monitor regional oxygenation changes across the cerebral cortex during surgery. Approach: The Flow system was assessed using two protocols. First, digital carotid compression was applied to healthy volunteers to cause a rapid oxygenation decrease across the ipsilateral hemisphere without affecting the contralateral side. Next, the system was used on patients undergoing shoulder surgery to provide continuous monitoring of cerebral oxygenation. In both protocols, the improved depth sensitivity of trNIRS was investigated by applying moment analysis. A dynamic wavelet filtering approach was also developed to remove observed temperature-induced signal drifts. Results: In the first protocol (28±5 years; five females, five males), hair significantly impacted regional sensitivity; however, the enhanced depth sensitivity of trNIRS was able to separate brain and scalp responses in the frontal region. Regional sensitivity was improved in the clinical study given the age-related reduction in hair density of the patients (65±15 years; 14 females, 13 males). In five patients who received phenylephrine to treat hypotension, different scalp and brain oxygenation responses were apparent, although no regional differences were observed. Conclusions: The Kernel Flow has promise as an intraoperative neuromonitoring device. Although regional sensitivity was affected by hair color and density, enhanced depth sensitivity of trNIRS was able to resolve differences in scalp and brain oxygenation responses in both protocols.


Asunto(s)
Circulación Cerebrovascular , Espectroscopía Infrarroja Corta , Humanos , Espectroscopía Infrarroja Corta/métodos , Espectroscopía Infrarroja Corta/instrumentación , Femenino , Masculino , Adulto , Circulación Cerebrovascular/fisiología , Hemodinámica/fisiología , Oximetría/métodos , Oximetría/instrumentación , Oxígeno/sangre , Oxígeno/metabolismo , Encéfalo/diagnóstico por imagen , Encéfalo/irrigación sanguínea , Diseño de Equipo
2.
Crit Care Explor ; 6(5): e1094, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38727717

RESUMEN

OBJECTIVES: Near-infrared spectroscopy (NIRS) is a potentially valuable modality to monitor the adequacy of oxygen delivery to the brain and other tissues in critically ill patients, but little is known about the physiologic determinants of NIRS-derived tissue oxygen saturations. The purpose of this study was to assess the contribution of routinely measured physiologic parameters to tissue oxygen saturation measured by NIRS. DESIGN: An observational sub-study of patients enrolled in the Role of Active Deresuscitation After Resuscitation-2 (RADAR-2) randomized feasibility trial. SETTING: Two ICUs in the United Kingdom. PATIENTS: Patients were recruited for the RADAR-2 study, which compared a conservative approach to fluid therapy and deresuscitation with usual care. Those included in this sub-study underwent continuous NIRS monitoring of cerebral oxygen saturations (SctO2) and quadriceps muscle tissue saturations (SmtO2). INTERVENTION: Synchronized and continuous mean arterial pressure (MAP), heart rate (HR), and pulse oximetry (oxygen saturation, Spo2) measurements were recorded alongside NIRS data. Arterial Paco2, Pao2, and hemoglobin concentration were recorded 12 hourly. Linear mixed effect models were used to investigate the association between these physiologic variables and cerebral and muscle tissue oxygen saturations. MEASUREMENTS AND MAIN RESULTS: Sixty-six patients were included in the analysis. Linear mixed models demonstrated that Paco2, Spo2, MAP, and HR were weakly associated with SctO2 but only explained 7.1% of the total variation. Spo2 and MAP were associated with SmtO2, but together only explained 0.8% of its total variation. The remaining variability was predominantly accounted for by between-subject differences. CONCLUSIONS: Our findings demonstrated that only a small proportion of variability in NIRS-derived cerebral and tissue oximetry measurements could be explained by routinely measured physiologic variables. We conclude that for NIRS to be a useful monitoring modality in critical care, considerable further research is required to understand physiologic determinants and prognostic significance.


Asunto(s)
Enfermedad Crítica , Oximetría , Saturación de Oxígeno , Espectroscopía Infrarroja Corta , Humanos , Espectroscopía Infrarroja Corta/métodos , Masculino , Femenino , Saturación de Oxígeno/fisiología , Persona de Mediana Edad , Anciano , Oximetría/métodos , Monitoreo Fisiológico/métodos , Encéfalo/metabolismo , Encéfalo/irrigación sanguínea , Reino Unido , Oxígeno/metabolismo , Oxígeno/sangre , Oxígeno/análisis , Unidades de Cuidados Intensivos , Músculo Cuádriceps/metabolismo , Músculo Cuádriceps/irrigación sanguínea
3.
Harm Reduct J ; 21(1): 89, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38702702

RESUMEN

BACKGROUND: In British Columbia, Canada, smoking is the most common modality of drug use among people who die of opioid toxicity. We aimed to assess oxygen saturation (SpO2) while people smoked opioids during a pilot study that introduced continuous pulse oximetry at overdose prevention services (OPS) sites. METHODS: This was an observational cohort study, using a participatory design. We implemented our monitoring protocol from March to August 2021 at four OPS. We included adults (≥ 18 years) presenting to smoke opioids. A sensor taped to participants' fingers transmitted real-time SpO2 readings to a remote monitor viewed by OPS staff. Peer researchers collected baseline data and observed the timing of participants' inhalations. We analyzed SpO2 on a per-event basis. In mixed-effects logistic regression models, drop in minimum SpO2 ≤ 90% in the current minute was our main outcome variable. Inhalation in that same minute was our main predictor. We also examined inhalation in the previous minute, cumulative inhalations, inhalation rate, demographics, co-morbidities, and substance use variables. RESULTS: We recorded 599 smoking events; 72.8% (436/599) had analyzable SpO2 data. Participants' mean age was 38.6 years (SD 11.3 years) and 73.1% were male. SpO2 was highly variable within and between individuals. Drop in SpO2 ≤ 90% was not significantly associated with inhalation in that same minute (OR: 1.2 [0.8-1.78], p = 0.261) or inhalation rate (OR 0.47 [0.20-1.10], p = 0.082). There was an association of SpO2 drop with six cumulative inhalations (OR 3.38 [1.04-11.03], p = 0.043); this was not maintained ≥ 7 inhalations. Demographics, co-morbidities, and drug use variables were non-contributory. CONCLUSIONS: Continuous pulse oximetry SpO2 monitoring is a safe adjunct to monitoring people who smoke opioids at OPS. Our data reflect challenges of real-world monitoring, indicating that greater supports are needed for frontline responders at OPS. Inconsistent association between inhalations and SpO2 suggests that complex factors (e.g., inhalation depth/duration, opioid tolerance, drug use setting) contribute to hypoxemia and overdose risk while people smoke opioids.


Asunto(s)
Analgésicos Opioides , Sobredosis de Droga , Oximetría , Humanos , Masculino , Femenino , Colombia Británica/epidemiología , Adulto , Persona de Mediana Edad , Sobredosis de Droga/prevención & control , Saturación de Oxígeno , Proyectos Piloto , Fumar/epidemiología , Estudios de Cohortes , Oxígeno/sangre , Reducción del Daño
4.
Artículo en Inglés | MEDLINE | ID: mdl-38684395

RESUMEN

PURPOSE: Goal-directed perfusion (GDP) refers to individualized goal-directed therapy using comprehensive monitoring and optimizing the delivery of oxygen during cardiopulmonary bypass (CPB). This study aims to determine whether the intraoperative GDP protocol method has better outcomes compared to conventional methods. METHODS: We searched the PubMed, Central, and Scopus databases up to October 12, 2023. We primarily examined the GDP protocol in adult cardiac surgery, using CPB with oxygen delivery index (DO2I) and cardiac index (CI) as the main parameters. RESULTS: In all, 1128 participants from seven studies were included in our analysis. The results showed significant differences in the duration of intensive care unit (ICU) stays (p = 0.01), with a mean difference of -0.33 (-0.59 to 0.07), and hospital length of stay (LOS) (p = 0.0002), with a mean difference of -0.84 (-1.29 to -0.39). There was also a notable reduction in postoperative complications (p <0.00001), odds ratio (OR) of 0.43 (0.32-0.60). However, there was no significant decrease in mortality rate (p = 0.54), OR of 0.77 (0.34-1.77). CONCLUSION: Postoperative acute kidney injury and ICU and hospital LOS are significantly reduced when GDP protocols with indicators of flow management, oxygen delivery index, and CI are used in intraoperative cardiac surgery using CPB.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Puente Cardiopulmonar , Tiempo de Internación , Humanos , Puente Cardiopulmonar/efectos adversos , Resultado del Tratamiento , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/mortalidad , Oxígeno/sangre , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Masculino , Anciano , Persona de Mediana Edad , Cuidados Intraoperatorios , Femenino , Factores de Tiempo , Monitoreo Intraoperatorio/métodos , Valor Predictivo de las Pruebas , Toma de Decisiones Clínicas , Gasto Cardíaco
5.
Intensive Care Med ; 50(5): 697-711, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38598124

RESUMEN

PURPOSE: Patients with hematological malignancies are at high risk for life-threatening complications. To date, little attention has been paid to the impact of hyperoxemia and excess oxygen use on mortality. The aim of this study was to investigate the association between partial pressure of arterial oxygen (PaO2) and 28-day mortality in critically ill patients with hematologic malignancies. METHODS: Data from three international cohorts (Europe, Canada, Oceania) of patients who received respiratory support (noninvasive ventilation, high-flow nasal cannula, invasive mechanical ventilation) were obtained. We used mixed-effect Cox models to investigate the association between day one PaO2 or excess oxygen use (inspired fraction of oxygen ≥ 0.6 with PaO2 > 100 mmHg) on day-28 mortality. RESULTS: 11,249 patients were included. On day one, 5716 patients (50.8%) had normoxemia (60 ≤ PaO2 ≤ 100 mmHg), 1454 (12.9%) hypoxemia (PaO2 < 60 mmHg), and 4079 patients (36.3%) hyperoxemia (PaO2 > 100 mmHg). Excess oxygen was used in 2201 patients (20%). Crude day-28 mortality rate was 40.6%. There was a significant association between PaO2 and day-28 mortality with a U-shaped relationship (p < 0.001). Higher PaO2 levels (> 100 mmHg) were associated with day-28 mortality with a dose-effect relationship. Subgroup analyses showed an association between hyperoxemia and mortality in patients admitted with neurological disorders; however, the opposite relationship was seen across those admitted with sepsis and neutropenia. Excess oxygen use was also associated with subsequent day-28 mortality (adjusted hazard ratio (aHR) [95% confidence interval (CI)]: 1.11[1.04-1.19]). This result persisted after propensity score analysis (matched HR associated with excess oxygen:1.31 [1.20-1.1.44]). CONCLUSION: In critically-ill patients with hematological malignancies, exposure to hyperoxemia and excess oxygen use were associated with increased mortality, with variable magnitude across subgroups. This might be a modifiable factor to improve mortality.


Asunto(s)
Enfermedad Crítica , Neoplasias Hematológicas , Oxígeno , Humanos , Neoplasias Hematológicas/mortalidad , Neoplasias Hematológicas/terapia , Neoplasias Hematológicas/complicaciones , Neoplasias Hematológicas/sangre , Masculino , Enfermedad Crítica/mortalidad , Femenino , Persona de Mediana Edad , Anciano , Oxígeno/sangre , Canadá/epidemiología , Modelos de Riesgos Proporcionales , Europa (Continente)/epidemiología , Adulto , Respiración Artificial/estadística & datos numéricos , Hiperoxia/mortalidad , Hiperoxia/etiología
6.
eNeuro ; 11(5)2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38641415

RESUMEN

Both the retina and brain exhibit neurovascular coupling, increased blood flow during increased neural activity. In the retina increased blood flow can be evoked by flickering light, but the magnitude of the metabolic change that underlies this is not known. Local changes in oxygen consumption (QO2) are difficult to measure in vivo when both supply and demand are changing. Here we isolated the C57BL/6J mouse retina and supplied it with oxygen from both sides of the tissue. Microelectrode recordings of PO2 were made in darkness and during 20 s of high scotopic flickering light at 1 Hz. Flicker led to a PO2 increase in the outer retina and a decrease in the inner retina, indicating that outer retinal QO2 (QOR) decreased and inner retinal QO2 (QIR) increased. A four-layer oxygen diffusion model was fitted to PO2 values obtained in darkness and at the end of flicker to determine the values of QOR and QIR. QOR in flicker was 76 ± 14% (mean and SD, n = 10) of QOR in darkness. The increase in QIR was smaller, 6.4 ± 5.0%. These metabolic changes are likely smaller than the maximum changes, because with no regeneration of pigment in the isolated retina, we limited the illumination. Further modeling indicated that at high illumination, QIR could increase by up to 45%, which is comparable to the magnitude of flow changes. This suggests that the blood flow increase is at least roughly matched to the increased metabolic demands of activity in the retina.


Asunto(s)
Ratones Endogámicos C57BL , Consumo de Oxígeno , Oxígeno , Estimulación Luminosa , Retina , Animales , Retina/metabolismo , Consumo de Oxígeno/fisiología , Estimulación Luminosa/métodos , Oxígeno/metabolismo , Oxígeno/sangre , Ratones , Masculino , Luz , Oscuridad , Acoplamiento Neurovascular/fisiología
7.
J Clin Anesth ; 95: 111465, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38581926

RESUMEN

OBJECTIVE: Test the hypothesis that one-lung ventilation with variable tidal volume improves intraoperative oxygenation and reduces postoperative pulmonary complications after lung resection. BACKGROUND: Constant tidal volume and respiratory rate ventilation can lead to atelectasis. Animal and human ARDS studies indicate that oxygenation improves with variable tidal volumes. Since one-lung ventilation shares characteristics with ARDS, we tested the hypothesis that one-lung ventilation with variable tidal volume improves intraoperative oxygenation and reduces postoperative pulmonary complications after lung resection. DESIGN: Randomized trial. SETTING: Operating rooms and a post-anesthesia care unit. PATIENTS: Adults having elective open or video-assisted thoracoscopic lung resection surgery with general anesthesia were randomly assigned to intraoperative ventilation with fixed (n = 70) or with variable (n = 70) tidal volumes. INTERVENTIONS: Patients assigned to fixed ventilation had a tidal volume of 6 ml/kgPBW, whereas those assigned to variable ventilation had tidal volumes ranging from 6 ml/kg PBW ± 33% which varied randomly at 5-min intervals. MEASUREMENTS: The primary outcome was intraoperative oxygenation; secondary outcomes were postoperative pulmonary complications, mortality within 90 days of surgery, heart rate, and SpO2/FiO2 ratio. RESULTS: Data from 128 patients were analyzed with 65 assigned to fixed-tidal volume ventilation and 63 to variable-tidal volume ventilation. The time-weighted average PaO2 during one-lung ventilation was 176 (86) mmHg in patients ventilated with fixed-tidal volume and 147 (72) mmHg in the patients ventilated with variable-tidal volume, a difference that was statistically significant (p < 0.01) but less than our pre-defined clinically meaningful threshold of 50 mmHg. At least one composite complication occurred in 11 (17%) of patients ventilated with variable-tidal volume and in 17 (26%) of patients assigned to fixed-tidal volume ventilation, with a relative risk of 0.67 (95% CI 0.34-1.31, p = 0.24). Atelectasis in the ventilated lung was less common with variable-tidal volumes (4.7%) than fixed-tidal volumes (20%) in the initial three postoperative days, with a relative risk of 0.24 (95% CI 0.01-0.8, p = 0.02), but there were no significant late postoperative differences. No other secondary outcomes were both statistically significant and clinically meaningful. CONCLUSION: One-lung ventilation with variable tidal volume does not meaningfully improve intraoperative oxygenation, and does not reduce postoperative pulmonary complications.


Asunto(s)
Anestesia General , Ventilación Unipulmonar , Complicaciones Posoperatorias , Volumen de Ventilación Pulmonar , Humanos , Ventilación Unipulmonar/métodos , Ventilación Unipulmonar/efectos adversos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Complicaciones Posoperatorias/prevención & control , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/epidemiología , Anestesia General/métodos , Oxígeno/sangre , Cirugía Torácica Asistida por Video/métodos , Cirugía Torácica Asistida por Video/efectos adversos , Resultado del Tratamiento , Neumonectomía/efectos adversos , Neumonectomía/métodos , Pulmón/cirugía , Frecuencia Cardíaca , Atelectasia Pulmonar/prevención & control , Atelectasia Pulmonar/etiología , Atelectasia Pulmonar/epidemiología
8.
J Clin Anesth ; 95: 111444, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38583224

RESUMEN

BACKGROUND: Mechanical ventilation with variable tidal volumes (V-VCV) has the potential to improve lung function during general anesthesia. We tested the hypothesis that V-VCV compared to conventional volume-controlled ventilation (C-VCV) would improve intraoperative arterial oxygenation and respiratory system mechanics in patients undergoing thoracic surgery under one-lung ventilation (OLV). METHODS: Patients were randomized to V-VCV (n = 39) or C-VCV (n = 39). During OLV tidal volume of 5 mL/kg predicted body weight (PBW) was used. Both groups were ventilated with a positive end-expiratory pressure (PEEP) of 5 cm H2O, inspiration to expiration ratio (I:E) of 1:1 (during OLV) and 1:2 during two-lung ventilation, the respiratory rate (RR) titrated to arterial pH, inspiratory peak-pressure ≤ 40 cm H2O and an inspiratory oxygen fraction of 1.0. RESULTS: Seventy-five out of 78 Patients completed the trial and were analyzed (dropouts were excluded). The partial pressure of arterial oxygen (PaO2) 20 min after the start of OLV did not differ among groups (V-VCV: 25.8 ± 14.6 kPa vs C-VCV: 27.2 ± 15.3 kPa; mean difference [95% CI]: 1.3 [-8.2, 5.5], P = 0.700). Furthermore, intraoperative gas exchange, intraoperative adverse events, need for rescue maneuvers due to desaturation and hypercapnia, incidence of postoperative pulmonary and extra-pulmonary complications, and hospital free days at day 30 after surgery did not differ between groups. CONCLUSIONS: In thoracic surgery patients under OLV, V-VCV did not improve oxygenation or respiratory system mechanics compared to C-VCV. Ethical Committee: EK 420092019. TRIAL REGISTRATION: at the German Clinical Trials Register: DRKS00022202 (16.06.2020).


Asunto(s)
Ventilación Unipulmonar , Intercambio Gaseoso Pulmonar , Mecánica Respiratoria , Procedimientos Quirúrgicos Torácicos , Volumen de Ventilación Pulmonar , Humanos , Ventilación Unipulmonar/métodos , Ventilación Unipulmonar/efectos adversos , Masculino , Femenino , Persona de Mediana Edad , Procedimientos Quirúrgicos Torácicos/efectos adversos , Procedimientos Quirúrgicos Torácicos/métodos , Anciano , Respiración con Presión Positiva/métodos , Respiración con Presión Positiva/efectos adversos , Anestesia General/métodos , Respiración Artificial/métodos , Oxígeno/sangre , Oxígeno/administración & dosificación
10.
Spectrochim Acta A Mol Biomol Spectrosc ; 315: 124298, 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38642522

RESUMEN

Acute mesenteric ischemia (AMI) is a clinically significant vascular and gastrointestinal condition, which is closely related to the blood supply of the small intestine. Unfortunately, it is still challenging to properly discriminate small intestinal tissues with different degrees of ischemia. In this study, hyperspectral imaging (HSI) was used to construct pseudo-color images of oxygen saturation about small intestinal tissues and to discriminate different degrees of ischemia. First, several small intestine tissue models of New Zealand white rabbits were prepared and collected their hyperspectral data. Then, a set of isosbestic points were used to linearly transform the measurement data twice to match the reference spectra of oxyhemoglobin and deoxyhemoglobin, respectively. The oxygen saturation was measured at the characteristic peak band of oxyhemoglobin (560 nm). Ultimately, using the oxygenated hemoglobin reflectance spectrum as the benchmark, we obtained the relative amount of median oxygen saturation in normal tissues was 70.0 %, the IQR was 10.1 %, the relative amount of median oxygen saturation in ischemic tissues was 49.6 %, and the IQR was 14.6 %. The results demonstrate that HSI combined with the oxygen saturation computation method can efficiently differentiate between normal and ischemic regions of the small intestinal tissues. This technique provides a powerful support for internist to discriminate small bowel tissues with different degrees of ischemia, and also provides a new way of thinking for the diagnosis of AMI.


Asunto(s)
Imágenes Hiperespectrales , Intestino Delgado , Necrosis , Saturación de Oxígeno , Oxígeno , Animales , Conejos , Intestino Delgado/irrigación sanguínea , Intestino Delgado/metabolismo , Intestino Delgado/patología , Oxígeno/sangre , Oxígeno/metabolismo , Imágenes Hiperespectrales/métodos , Oxihemoglobinas/análisis , Oxihemoglobinas/metabolismo , Hemoglobinas/análisis
11.
J Anesth ; 38(3): 364-370, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38502324

RESUMEN

PURPOSE: Though the finger is generally recommended for pulse oxygen saturation (SpO2) monitoring site, its reliability may be compromised in conditions of poor peripheral perfusion. Therefore, we compared the performance of nasal septum SpO2 monitoring with finger SpO2 monitoring relative to simultaneous arterial oxygen saturation (SaO2) monitoring in generally anesthetized patients. METHODS: In 23 adult patients, comparisons of SpO2 measured at the nasal septum and finger with simultaneous SaO2 were made at four time points during the 90 min study period. A pulse oximetry monitoring failure was defined as a > 10 s continuous failure of in an adequate SpO2 data acquisition. Core temperature as well as finger-tip and nasal septum temperatures were simultaneously measured at 10 min intervals. RESULTS: A total of 92 sets of SpO2 and SaO2 measurements were obtained in 23 patients. The bias and precision for SpO2 measured at the nasal septum were - 0.8 ± 1.3 (95% confidence interval: - 1.1 to - 0.6), which was similar to those for SpO2 measured at the finger (- 0.6 ± 1.4; 95% confidence interval: - 0.9 to - 0.4) (p = 0.154). Finger-tip temperatures were consistently lower than other two temperatures at all time points (p < 0.05), reaching 33.5 ± 2.3 °C at 90 min after induction of anesthesia. While pulse oximetry monitoring failure did not occur for nasal septum probe, two cases of failure occurred for finger probe. CONCLUSIONS: Considering the higher stability to hypothermia with a similar accuracy, nasal septum pulse oximetry may be an attractive alternative to finger pulse oximetry. Trail registration This study was registered with Clinical Research Information Service (CRIS: https://cris.nih.go.kr/cris/en/ ; ref: KCT0008352).


Asunto(s)
Anestesia General , Dedos , Tabique Nasal , Oximetría , Saturación de Oxígeno , Humanos , Oximetría/métodos , Oximetría/instrumentación , Dedos/irrigación sanguínea , Masculino , Femenino , Anestesia General/métodos , Persona de Mediana Edad , Tabique Nasal/cirugía , Adulto , Saturación de Oxígeno/fisiología , Temperatura Corporal/fisiología , Monitoreo Intraoperatorio/métodos , Monitoreo Intraoperatorio/instrumentación , Anciano , Reproducibilidad de los Resultados , Oxígeno/sangre
12.
Eur J Pediatr ; 183(5): 2455-2461, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38470520

RESUMEN

High concentrations of oxygen are often needed to optimize oxygenation in infants with persistent pulmonary hypertension (PPHN), but this can also increase the risk of hyperoxemia. We determined the occurrence of hyperoxemia in infants treated for PPHN. Medical records of infants ≥ 34 + 0 weeks gestational age (GA) who received inhaled nitric oxide (iNO) were retrospectively reviewed for oxygenation parameters during iNO therapy. Oxygen was manually titrated to target arterial oxygen tension (PaO2) 10-13 kPa and peripheral oxygen saturation (SpO2) 92-98%. The main study outcomes were the incidence and duration of hyperoxemia and hypoxemia and the fraction of inspired oxygen (FiO2). A total of 181 infants were included. The median FiO2 was 0.43 (IQR 0.34-0.56) and the maximum FiO2 was 1.0 in 156/181 (86%) infants, resulting in at least one PaO2 > 13 kPa in 149/181 (82%) infants, of which 46/149 (31%) infants had minimal one PaO2 > 30 kPa. SpO2 was > 98% in 179/181 (99%) infants for 17.7% (8.2-35.6%) of the iNO time. PaO2 < 10 kPa occurred in 160/181 (88%) infants, of which 81/160 (51%) infants had minimal one PaO2 < 6.7 kPa. SpO2 was < 92% in 169/181 (93%) infants for 1.6% (0.5-4.3%) of the iNO time.    Conclusion: While treatment of PPHN is focused on preventing and reversing hypoxemia, hyperoxemia occurs inadvertently in most patients. What is Known: • High concentrations of oxygen are often needed to prevent hypoxemia-induced deterioration of PPHN, but this can also increase the risk of hyperoxemia. • Infants with persistent pulmonary hypertension may be particularly vulnerable to the toxic effects of oxygen, and hyperoxemia could further induce pulmonary vasoconstriction, potentially worsening the condition. What is New: • Hyperoxemia occurs in the majority of infants with PPHN during treatment with iNO. • Infants with PPHN spent a considerably longer period with saturations above the target range compared to saturations below the target range.


Asunto(s)
Hiperoxia , Óxido Nítrico , Síndrome de Circulación Fetal Persistente , Humanos , Recién Nacido , Hiperoxia/etiología , Óxido Nítrico/administración & dosificación , Estudios Retrospectivos , Síndrome de Circulación Fetal Persistente/terapia , Masculino , Femenino , Administración por Inhalación , Oxígeno/sangre , Oxígeno/administración & dosificación , Saturación de Oxígeno , Terapia por Inhalación de Oxígeno/métodos , Hipoxia/etiología , Hipoxia/terapia
13.
J Cogn Neurosci ; 36(6): 1071-1098, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38527084

RESUMEN

We examined the initial stages of orthographic learning in real time as literate adults learned spellings for spoken pseudowords during fMRI scanning. Participants were required to learn and store orthographic word forms because the pseudoword spellings were not uniquely predictable from sound to letter mappings. With eight learning trials per word form, we observed changes in the brain's response as learning was taking place. Accuracy was evaluated during learning, immediately after scanning, and 1 week later. We found evidence of two distinct learning systems-hippocampal and neocortical-operating during orthographic learning, consistent with the predictions of dual systems theories of learning/memory such as the complementary learning systems framework [McClelland, J. L., McNaughton, B. L., & O'Reilly, R. C. Why there are complementary learning systems in the hippocampus and neocortex: Insights from the successes and failures of connectionist models of learning and memory. Psychological Review, 102, 419-457, 1995]. The bilateral hippocampus and the visual word form area (VWFA) showed significant BOLD response changes over learning, with the former exhibiting a rising pattern and the latter exhibiting a falling pattern. Moreover, greater BOLD signal increase in the hippocampus was associated with better postscan recall. In addition, we identified two distinct bilateral brain networks that mirrored the rising and falling patterns of the hippocampus and VWFA. Functional connectivity analysis revealed that regions within each network were internally synchronized. These novel findings highlight, for the first time, the relevance of multiple learning systems in orthographic learning and provide a paradigm that can be used to address critical gaps in our understanding of the neural bases of orthographic learning in general and orthographic word-form learning specifically.


Asunto(s)
Mapeo Encefálico , Imagen por Resonancia Magnética , Humanos , Masculino , Femenino , Adulto Joven , Adulto , Aprendizaje/fisiología , Lectura , Aprendizaje Verbal/fisiología , Oxígeno/sangre , Hipocampo/fisiología , Hipocampo/diagnóstico por imagen , Corteza Cerebral/fisiología , Corteza Cerebral/diagnóstico por imagen , Reconocimiento Visual de Modelos/fisiología
14.
Am J Physiol Endocrinol Metab ; 326(5): E640-E647, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38536038

RESUMEN

Long-term hyperglycemia in individuals with type 2 diabetes (T2D) can detrimentally impact pulmonary function and muscle oxygenation. As a result, these factors can impede the body's adaptation to physical exertion. We aimed to evaluate the oxygen pathway during maximal exercise among overweight/obese individuals with type 2 diabetes free from complications, in comparison with a group of matched overweight/obese individuals without diabetes, specifically concentrating on the effects on pulmonary function and muscle oxygenation. Fifteen overweight/obese adults with type 2 diabetes [glycated hemoglobin (HbA1c) = 8.3 ± 1.2%] and 15 matched overweight/obese adults without diabetes underwent pre- and post exercise lung function assessment. A maximal incremental exercise test was conducted, monitoring muscle oxygenation using near-infrared spectroscopy and collecting arterial blood gas samples. Both groups exhibited normal lung volumes at rest and after exercise. Spirometric lung function did not significantly differ pre- and post exercise in either group. During maximal exercise, the type 2 diabetes group showed significantly lower augmentation in total hemoglobin and deoxygenated hemoglobin compared with the control group. Despite comparable usual physical activity levels and comparable heart rates at exhaustion, the type 2 diabetes group had a lower peak oxygen consumption than controls. No significant differences were found in arterial blood gas analyses ([Formula: see text], [Formula: see text], [Formula: see text], and [Formula: see text]) between the groups. Individuals with type 2 diabetes free from complications displayed normal pulmonary function at rest and post exercise. However, impaired skeletal muscle oxygenation during exercise, resulting from reduced limb blood volume and altered muscle deoxygenation, may contribute to the lower V̇o2peak observed in this population.NEW & NOTEWORTHY Individuals with type 2 diabetes free from micro- and macrovascular complications have normal resting pulmonary function, but their V̇o2peak is impaired due to poor skeletal muscle oxygenation during exercise. Tailoring exercise regimes for this population should prioritize interventions aimed at enhancing muscle oxygenation and blood flow improvement.


Asunto(s)
Diabetes Mellitus Tipo 2 , Músculo Esquelético , Consumo de Oxígeno , Humanos , Diabetes Mellitus Tipo 2/metabolismo , Diabetes Mellitus Tipo 2/fisiopatología , Diabetes Mellitus Tipo 2/complicaciones , Masculino , Persona de Mediana Edad , Femenino , Consumo de Oxígeno/fisiología , Músculo Esquelético/metabolismo , Músculo Esquelético/fisiopatología , Adulto , Ejercicio Físico/fisiología , Prueba de Esfuerzo , Obesidad/metabolismo , Obesidad/fisiopatología , Obesidad/complicaciones , Oxígeno/metabolismo , Oxígeno/sangre , Pulmón/fisiopatología , Pulmón/metabolismo , Espectroscopía Infrarroja Corta , Sobrepeso/metabolismo , Sobrepeso/fisiopatología , Sobrepeso/complicaciones , Estudios de Casos y Controles , Pruebas de Función Respiratoria
15.
J Cardiothorac Vasc Anesth ; 38(6): 1322-1327, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38523024

RESUMEN

OBJECTIVE AND DESIGN: A single-center prospective randomized controlled study was conducted to assess the effect of targeted mild hypercapnia (TMH) on cerebral oxygen saturation (rSO2) in patients undergoing off-pump coronary artery bypass grafting (CABG). SETTING AND PARTICIPANTS: A prospective randomized controlled study involving 100 patients undergoing off-pump CABG at U. N. Mehta Hospital, Ahmedabad, Gujarat, India. INTERVENTION: Patients were randomized to either the TMH (PaCO2 45-55 mmHg) or the targeted normocapnia (TN; PaCO2 35-45 mmHg) group, containing 50 patients in each group. MEASUREMENTS: Monitoring of rSO2, heart rate, mean arterial pressure (MAP), PaCO2, and peripheral oxygen saturation was done at baseline, after induction, after left internal mammary artery harvesting, at each grafting (distal and proximal), after protamine, and after shifting to the intensive care unit. The standardized minimental-state examination (SMMSE) was performed preoperatively and at 8, 12, and 24 hours postextubation. Data were analyzed using an independent sample t test. RESULTS: The TMH group had higher MAP during grafting (p < 0.001) and higher rSO2 on both sides during distal and proximal grafting (p < 0.001) and after protamine (p < 0.05), as compared to the TN group. Compared to preoperative values, SMMSE scores in the TN group were significantly lower at 12 and 24 hours postextubation (p < 0.001). CONCLUSION: TMH during grafting increased the cerebral blood flow and rSO2 when hemodynamic instability was very common. It has a protective role on the brain and helps maintain cognition postoperatively.


Asunto(s)
Circulación Cerebrovascular , Puente de Arteria Coronaria Off-Pump , Hipercapnia , Saturación de Oxígeno , Humanos , Puente de Arteria Coronaria Off-Pump/métodos , Masculino , Hipercapnia/metabolismo , Hipercapnia/sangre , Persona de Mediana Edad , Femenino , Proyectos Piloto , Estudios Prospectivos , Saturación de Oxígeno/fisiología , Anciano , Circulación Cerebrovascular/fisiología , Oxígeno/sangre , Oxígeno/metabolismo , Encéfalo/metabolismo
16.
Science ; 383(6690): 1471-1478, 2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38547288

RESUMEN

Consciousness is lost within seconds upon cessation of cerebral blood flow. The brain cannot store oxygen, and interruption of oxidative phosphorylation is fatal within minutes. Yet only rudimentary knowledge exists regarding cortical partial oxygen tension (Po2) dynamics under physiological conditions. Here we introduce Green enhanced Nano-lantern (GeNL), a genetically encoded bioluminescent oxygen indicator for Po2 imaging. In awake behaving mice, we uncover the existence of spontaneous, spatially defined "hypoxic pockets" and demonstrate their linkage to the abrogation of local capillary flow. Exercise reduced the burden of hypoxic pockets by 52% compared with rest. The study provides insight into cortical oxygen dynamics in awake behaving animals and concurrently establishes a tool to delineate the importance of oxygen tension in physiological processes and neurological diseases.


Asunto(s)
Corteza Cerebral , Circulación Cerebrovascular , Hipoxia Encefálica , Mediciones Luminiscentes , Saturación de Oxígeno , Oxígeno , Animales , Ratones , Corteza Cerebral/irrigación sanguínea , Corteza Cerebral/diagnóstico por imagen , Corteza Cerebral/metabolismo , Oxígeno/sangre , Oxígeno/metabolismo , Presión Parcial , Hipoxia Encefálica/sangre , Hipoxia Encefálica/diagnóstico por imagen , Hipoxia Encefálica/metabolismo , Vasodilatación , Mediciones Luminiscentes/métodos , Luciferasas/genética , Luciferasas/metabolismo , Proteínas Recombinantes de Fusión/genética , Proteínas Recombinantes de Fusión/metabolismo , Proteínas Fluorescentes Verdes/genética , Proteínas Fluorescentes Verdes/metabolismo , Hipercapnia/sangre , Hipercapnia/diagnóstico por imagen , Hipercapnia/metabolismo
19.
J Cogn Neurosci ; 36(6): 1156-1171, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38437186

RESUMEN

Should we keep doing what we know works for us, or should we risk trying something new as it could work even better? The exploration-exploitation dilemma is ubiquitous in daily life decision-making, and balancing between the two is crucial for adaptive behavior. Yet, we only have started to unravel the neurocognitive mechanisms that help us to find this balance in practice. Analyzing BOLD signals of healthy young adults during virtual foraging, we could show that a behavioral tendency for prolonged exploitation was associated with weakened signaling during exploration in central node points of the frontoparietal attention network, plus the frontopolar cortex. These results provide an important link between behavioral heuristics that we use to balance between exploitation and exploration and the brain function that supports shifts from one tendency to the other. Importantly, they stress that interindividual differences in behavioral strategies are reflected in differences in brain activity during exploration and should thus be more in the focus of basic research that aims at delineating general laws governing visual attention.


Asunto(s)
Imagen por Resonancia Magnética , Humanos , Masculino , Femenino , Adulto Joven , Adulto , Atención/fisiología , Conducta Exploratoria/fisiología , Mapeo Encefálico , Lóbulo Frontal/fisiología , Oxígeno/sangre , Toma de Decisiones/fisiología
20.
Animal Model Exp Med ; 7(2): 156-165, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38506157

RESUMEN

INTRODUCTION: Hypoxic pulmonary vasoconstriction (HPV) can be a challenging clinical problem. It is not fully elucidated where in the circulation the regulation of resistance takes place. It is often referred to as if it is in the arteries, but we hypothesized that it is in the venous side of the pulmonary circulation. METHODS: In an open thorax model, pigs were treated with a veno-venous extra corporeal membrane oxygenator to either oxygenate or deoxygenate blood passing through the pulmonary vessels. At the same time the lungs were ventilated with extreme variations of inspired air from 5% to 100% oxygen, making it possible to make combinations of high and low oxygen content through the pulmonary circulation. A flow probe was inserted around the main pulmonary artery and catheters in the pulmonary artery and in the left atrium were used for pressure monitoring and blood tests. Under different combinations of oxygenation, pulmonary vascular resistance (PVR) was calculated. RESULTS: With unchanged level of oxygen in the pulmonary artery and reduced inspired oxygen fraction lowering oxygen tension from 29 to 6.7 kPa in the pulmonary vein, PVR was doubled. With more extreme hypoxia PVR suddenly decreased. Combinations with low oxygenation in the pulmonary artery did not systematic influence PVR if there was enough oxygen in the inspired air and in the pulmonary veins. DISCUSSION: The impact of hypoxia occurs from the alveolar level and forward with the blood flow. The experiments indicated that the regulation of PVR is mediated from the venous side.


Asunto(s)
Hipoxia , Oxígeno , Arteria Pulmonar , Venas Pulmonares , Resistencia Vascular , Animales , Arteria Pulmonar/fisiopatología , Hipoxia/fisiopatología , Oxígeno/metabolismo , Oxígeno/sangre , Porcinos , Circulación Pulmonar , Vasoconstricción
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...