1.
Mil Med ; 189(Supplement_3): 448-455, 2024 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-39160881

RESUMEN

INTRODUCTION: Current standards for hemoglobin monitoring during air transports of U.S. combat wounded are invasive and intermittent. Fielded pulse co-oximeters can noninvasively measure total hemoglobin, but this parameter is not currently utilized. The primary objective of this study was to assess the percentage of vital sign measurements with successful capture of total noninvasive hemoglobin measurement using spectrophotometry-based technology for Hb (SpHb) measurements in healthy participants during training flights. Secondary objectives were to assess the feasibility of a novel electronic data capture mechanism from usual patient movement items and perform a pilot analysis of SpHb changes in healthy participants during transitions from ground to air transport. METHODS: We conducted a feasibility study enrolling healthy participants who had hemodynamic monitoring during usual U.S. Air Force Critical Care Air Transport (CCAT) flight training exercises from 2022 to 2023. Usual CCAT monitoring equipment and currently used Masimo Rainbow® pulse co-oximeters had the capability to measure SpHb. After each training exercise, the study team wirelessly downloaded case files from patient monitors utilizing the Battlefield Assisted Trauma Distributed Observation Kit (BATDOKTM) Case Downloader application. We then calculated point and precision estimates for the percentage of time for successful SpHb capture during the exercise and compared this to pulse oximetry (SpO2) capture. An a priori precision analysis for percentage of flight-time with successful SpHb data capture and descriptive statistics were performed. This study received Exempt Determination by the 59th Medical Wing IRB. RESULTS: We analyzed 26 records with mean monitoring durations of 94.5 [59.3-119.9] minutes during ground phases and 78.0 [59.9-106.5] minutes during flight phases. SpHb measures were successfully captured for 97.7% (n = 4,620) of possible ground measurements and 97.2% (n = 3,973) of possible in-flight measurements compared to 99.5% ground and 98.2% in-flight capture for SpO2. Mean intervals of missing SpHb data were 2 ± 5 minutes on the ground and 4 ± 6 minutes in-flight. Mean SpHb increased by 0.93 ± 0.96 g/dL during the ground phase, but had minimal changes during ascent, cruising altitude or descent. The BATDOKTM Case downloader completed transfer for all files. CONCLUSION: Masimo Rainbow® SpHb pulse co-oximeters reliably captured continuous, noninvasive hemoglobin measurements using usual CCAT patient movement items in healthy participants during both ground and flight training. The BATDOKTM Case Downloader successfully imported case files from CCAT patient monitors. Mean SpHb measures had a small increase during the ground phase of monitoring followed by minimal changes when transitioning to flight altitude.


Asunto(s)
Oximetría , Humanos , Ambulancias Aéreas/estadística & datos numéricos , Estudios de Factibilidad , Voluntarios Sanos/estadística & datos numéricos , Hemoglobinas/análisis , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/estadística & datos numéricos , Monitoreo Fisiológico/normas , Oximetría/métodos , Oximetría/normas , Oximetría/instrumentación , Oximetría/estadística & datos numéricos , Reproducibilidad de los Resultados
2.
Sci Rep ; 14(1): 19117, 2024 08 18.
Artículo en Inglés | MEDLINE | ID: mdl-39155284

RESUMEN

Accurate assessment of vital parameters is essential for diagnosis and triage of critically ill patients, but not always feasible in out-of-hospital settings due to the lack of suitable devices. We performed an extensive validation of a novel prototype in-ear device, which was proposed for the non-invasive, combined measurement of core body temperature (Tc), oxygen saturation (SpO2), and heart rate (HR) in harsh environments. A pilot study with randomized controlled design was conducted in the terraXcube environmental chamber. Participants were subsequently exposed to three 15 min test sessions at the controlled ambient temperatures of 20 °C, 5 °C, and - 10 °C, in randomized order. Vital parameters measured by the prototype were compared with Tc measurements from commercial esophageal (reference) and tympanic (comparator) probes and SpO2 and HR measurements from a finger pulse-oximeter (reference). Performance was assessed in terms of bias and Lin's correlation coefficient (CCC) with respect to the reference measurements and analyzed with linear mixed models. Twenty-three participants (12 men, mean (SD) age, 35 (9) years) completed the experimental protocol. The mean Tc bias of the prototype ranged between - 0.39 and - 0.80 °C at ambient temperatures of 20 °C and 5 °C, and it reached - 1.38 °C only after 15 min of exposure to - 10 °C. CCC values ranged between 0.07 and 0.25. SpO2 and HR monitoring was feasible, although malfunctioning was observed in one third of the tests. SpO2 and HR bias did not show any significant dependence on environmental conditions, with values ranging from - 1.71 to - 0.52% for SpO2 and 1.12 bpm to 5.30 bpm for HR. High CCC values between 0.81 and 0.97 were observed for HR in all environmental conditions. This novel prototype device for measuring vital parameters in cold environments demonstrated reliability of Tc measurements and feasibility of SpO2 and HR monitoring. Through non-invasive and accurate monitoring of vital parameters from the ear canal our prototype may offer support in triage and treatment of critically ill patients in harsh out-of-hospital conditions.


Asunto(s)
Temperatura Corporal , Frecuencia Cardíaca , Humanos , Masculino , Femenino , Adulto , Frecuencia Cardíaca/fisiología , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Proyectos Piloto , Oximetría/instrumentación , Oximetría/métodos , Saturación de Oxígeno/fisiología , Persona de Mediana Edad , Temperatura
3.
BMC Vet Res ; 20(1): 319, 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39014383

RESUMEN

BACKGROUND: Monitoring blood oxygenation is essential in immobilised rhinoceros, which are susceptible to opioid-induced hypoxaemia. This study assessed the reliability, clinical performance and trending ability of the Nonin PalmSAT 2500 A pulse oximeter's and the Masimo Radical-7 pulse co-oximeter's dual-wavelength technology, with their probes placed at two measurement sites, the inner surface of the third-eyelid and the scarified ear pinna of immobilised white rhinoceroses. Eight white rhinoceros were immobilised with etorphine-based drug combinations and given butorphanol after 12 min, and oxygen after 40 min, of recumbency. The Nonin and Masimo devices, with dual-wavelength probes attached to the third-eyelid and ear recorded arterial peripheral oxygen-haemoglobin saturation (SpO2) at pre-determined time points, concurrently with measurements of arterial oxygen-haemoglobin saturation (SaO2), from drawn blood samples, by a benchtop AVOXimeter 4000 co-oximeter (reference method). Reliability of the Nonin and Masimo devices was evaluated using the Bland-Altman and the area root mean squares (ARMS) methods. Clinical performance of the devices was evaluated for their ability to accurately detect clinical hypoxemia using receiver operating characteristic (ROC) curves and measures of sensitivity, specificity, and positive and negative predictive values. Trending ability of the devices was assessed by calculating concordance rates from four-quadrant plots. RESULTS: Only the Nonin device with transflectance probe attached to the third-eyelid provided reliable SpO2 measurements across the 70 to 100% saturation range (bias - 1%, precision 4%, ARMS 4%). Nonin and Masimo devices with transflectance probes attached to the third-eyelid both had high clinical performance at detecting clinical hypoxaemia [area under the ROC curves (AUC): 0.93 and 0.90, respectively]. However, the Nonin and Masimo devices with transmission probes attached to the ear were unreliable and provided only moderate clinical performance. Both Nonin and Masimo devices, at both measurement sites, had concordance rates lower than the recommended threshold of ≥ 90%, indicating poor trending ability. CONCLUSIONS: The overall assessment of reliability, clinical performance and trending ability indicate that the Nonin device with transflectance probe attached to the third-eyelid is best suited for monitoring of blood oxygenation in immobilised rhinoceros. The immobilisation procedure may have affected cardiovascular function to an extent that it limited the devices' performance.


Asunto(s)
Oximetría , Oxígeno , Perisodáctilos , Animales , Perisodáctilos/sangre , Oximetría/veterinaria , Oximetría/instrumentación , Oximetría/métodos , Reproducibilidad de los Resultados , Oxígeno/sangre , Masculino , Inmovilización/veterinaria , Inmovilización/instrumentación , Inmovilización/métodos , Femenino
4.
Health Informatics J ; 30(2): 14604582241259341, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38847787

RESUMEN

This study develops machine learning-based algorithms that facilitate accurate prediction of cerebral oxygen saturation using waveform data in the near-infrared range from a multi-modal oxygen saturation sensor. Data were obtained from 150,000 observations of a popular cerebral oximeter, Masimo O3™ regional oximetry (Co., United States) and a multi-modal cerebral oximeter, Votem (Inc., Korea). Among these observations, 112,500 (75%) and 37,500 (25%) were used for training and test sets, respectively. The dependent variable was the cerebral oxygen saturation value from the Masimo O3™ (0-100%). The independent variables were the time of measurement (0-300,000 ms) and the 16-bit decimal amplitudes values (infrared and red) from Votem (0-65,535). For the right part of the forehead, the root mean square error of the random forest (0.06) was much smaller than those of linear regression (1.22) and the artificial neural network with one, two or three hidden layers (2.58). The result was similar for the left part of forehead, that is, random forest (0.05) vs logistic regression (1.22) and the artificial neural network with one, two or three hidden layers (2.97). Machine learning aids in accurately predicting of cerebral oxygen saturation, employing the data from a multi-modal cerebral oximeter.


Asunto(s)
Aprendizaje Automático , Oximetría , Saturación de Oxígeno , Humanos , Oximetría/métodos , Oximetría/instrumentación , Oximetría/estadística & datos numéricos , Saturación de Oxígeno/fisiología , Algoritmos , Femenino , Masculino , Oxígeno/metabolismo , Oxígeno/análisis
5.
JMIR Hum Factors ; 11: e54983, 2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38825834

RESUMEN

Background: Pulse oximeters noninvasively measure blood oxygen levels, but these devices have rarely been designed for low-resource settings and are inconsistently available at outpatient clinics. Objective: The Phefumla project aims to develop and validate a pediatric smartphone-based pulse oximeter designed specifically for this context. We present the process of human-centered oximeter design with health care workers in South Africa. Methods: We purposively sampled 19 health care workers from 5 clinics in Khayelitsha, Cape Town. Using a human-centered design approach, we conducted participatory workshops with four activities with health care workers: (1) they received 3D-printed prototypes of potential oximeter designs to provide feedback; (2) we demonstrated on dolls how they would use the novel oximeter; (3) they used pile sorting to rank design features and suggest additional features they desired; and (4) they designed their preferred user interface using a whiteboard, marker, and magnetized features that could be repositioned. We audio recorded the workshops, photographed outputs, and took detailed field notes. Analysis involved iterative review of these data to describe preferences, identify key design updates, and provide modifications. Results: Participants expressed a positive sentiment toward the idea of a smartphone pulse oximeter and suggested that a pediatric device would address an important gap in outpatient care. Specifically, participants expressed a preference for the prototype that they felt enabled more diversity in the way it could be used. There was a strong tendency to prioritize pragmatic design features, such as robustness, which was largely dictated by health care worker context. They also added features that would allow the oximeter device to serve other clinical functions in addition to oxygen saturation measurement, such as temperature and respiratory rate measurements. Conclusions: Our end user-centered rapid participatory approach led to tangible design changes and prompted design discussions that the team had not previously considered. Overall, health care workers prioritized pragmatism for pediatric pulse oximeter device design.


Asunto(s)
Personal de Salud , Oximetría , Teléfono Inteligente , Humanos , Sudáfrica , Oximetría/instrumentación , Oximetría/métodos , Diseño de Equipo , Investigación Cualitativa , Diseño Centrado en el Usuario , Niño , Femenino , Masculino
6.
Sensors (Basel) ; 24(11)2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38894093

RESUMEN

Pulse oximeters are widely used in hospitals and homes for measurement of blood oxygen saturation level (SpO2) and heart rate (HR). Concern has been raised regarding a possible bias in obtaining pulse oximeter measurements from different fingertips and the potential effect of skin pigmentation (white, brown, and dark). In this study, we obtained 600 SpO2 measurements from 20 volunteers using three UK NHS-approved commercial pulse oximeters alongside our custom-developed sensor, and used the Munsell colour system (5YR and 7.5YR cards) to classify the participants' skin pigmentation into three distinct categories (white, brown, and dark). The statistical analysis using ANOVA post hoc tests (Bonferroni correction), a Bland-Altman plot, and a correlation test were then carried out to determine if there was clinical significance in measuring the SpO2 from different fingertips and to highlight if skin pigmentation affects the accuracy of SpO2 measurement. The results indicate that although the three commercial pulse oximeters had different means and standard deviations, these differences had no clinical significance.


Asunto(s)
Dedos , Oximetría , Saturación de Oxígeno , Pigmentación de la Piel , Humanos , Oximetría/métodos , Oximetría/instrumentación , Pigmentación de la Piel/fisiología , Dedos/irrigación sanguínea , Dedos/fisiología , Saturación de Oxígeno/fisiología , Masculino , Adulto , Femenino , Oxígeno/sangre , Oxígeno/metabolismo , Frecuencia Cardíaca/fisiología , Adulto Joven
7.
Zhonghua Jie He He Hu Xi Za Zhi ; 47(6): 529-534, 2024 Jun 12.
Artículo en Chino | MEDLINE | ID: mdl-38858202

RESUMEN

Objective: To evaluate the application value of portable pulse oximeter in adult obstructive sleep apnea (OSA). Methods: This study prospectively enrolled adult patients who underwent polysomnography (PSG) due to snoring at the Respiratory and Sleep Medicine Department of Peking University People's Hospital from July 2022 to July 2023. During PSG monitoring, CS-WOxi was continuously used to monitor blood oxygen levels. The consistency between 3% oxygen desaturation index (ODI3) measured by portable pulse oximeter and ODI3 of polysomnography was evaluated using difference test, Pearson's correlation coefficient, and Bland-altman method. Receiver operating characteristic curve was used to determine the optimal threshold for diagnosing OSA. Results: A total of 184 subjects were included, including 121 males (65.8%) and 63 females (34.2%). The mean age was 46.0 (34.3, 59.0) years, body mass index was 26.0 (23.3, 29.6) kg/m², and the apnea-hypopnea index was 18.2 (5.8, 40.8) events/h. There was a significant difference between CS-ODI3 and PSG-ODI3 [17.1(6.2, 42.7) vs. 14.0(2.9, 32.6), P<0.001], and the Pearson correlation coefficient was 0.93 (P<0.001). There was a good correlation between CS-ODI3 and PSG-AHI (r=0.92, P<0.001). Bland-Altman consistency test showed that the average difference between the two was 0.7 events/h, and the 95% consistency limit was (-17.9, 19.3 events/h). When the CS-ODI3≥5 events/h was used to identify OSA, the sensitivity was 94.4%, the specificity was 80.0%, and the accuracy was 91.3%. When PSG-AHI≥5 events/h was used as the diagnostic criteria, the area under the receiver operating characteristic curve was 0.933. Conclusion: Portable pulse oximeter can monitor pulse oxygen saturation accurately and has good sensitivity and specificity for OSA high-risk patients, and is a reliable tool for OSA screening.


Asunto(s)
Oximetría , Polisomnografía , Apnea Obstructiva del Sueño , Humanos , Apnea Obstructiva del Sueño/diagnóstico , Apnea Obstructiva del Sueño/sangre , Oximetría/métodos , Oximetría/instrumentación , Femenino , Masculino , Persona de Mediana Edad , Adulto , Polisomnografía/métodos , Estudios Prospectivos , Curva ROC , Sensibilidad y Especificidad , Índice de Masa Corporal , Oxígeno/sangre
8.
J Magn Reson ; 362: 107690, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38692250

RESUMEN

This research report describes a novel surface dielectric resonator (SDR) with a flexible connector for in vivo electron paramagnetic resonance (EPR) spectroscopy. Contrary to the conventional cavity or surface loop-gap resonators, the newly developed SDR is constructed from a ceramic dielectric material, and it is tuned to operate at the L-band frequency band (1.15 GHz) in continuous-wave mode. The SDR is designed to be critically coupled and capable of working with both very lossy samples, such as biological tissues, and non-lossy materials. The SDR was characterized using electromagnetic field simulations, assessed for sensitivity with a B1 field-perturbation method, and validated with tissue phantoms using EPR measurements. The results showed remarkably higher sensitivity in lossy tissue phantoms than the previously reported multisegment surface-loop resonators. The new SDR can provide potential new insights for advancements in the application of in vivo EPR spectroscopy for biological measurements, including clinical oximetry.


Asunto(s)
Campos Electromagnéticos , Diseño de Equipo , Fantasmas de Imagen , Espectroscopía de Resonancia por Spin del Electrón/métodos , Espectroscopía de Resonancia por Spin del Electrón/instrumentación , Reproducibilidad de los Resultados , Oximetría/instrumentación , Oximetría/métodos
9.
J Biomed Opt ; 29(Suppl 3): S33302, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38707651

RESUMEN

Significance: Cerebral oximeters have the potential to detect abnormal cerebral blood oxygenation to allow for early intervention. However, current commercial systems have two major limitations: (1) spatial coverage of only the frontal region, assuming that surgery-related hemodynamic effects are global and (2) susceptibility to extracerebral signal contamination inherent to continuous-wave near-infrared spectroscopy (NIRS). Aim: This work aimed to assess the feasibility of a high-density, time-resolved (tr) NIRS device (Kernel Flow) to monitor regional oxygenation changes across the cerebral cortex during surgery. Approach: The Flow system was assessed using two protocols. First, digital carotid compression was applied to healthy volunteers to cause a rapid oxygenation decrease across the ipsilateral hemisphere without affecting the contralateral side. Next, the system was used on patients undergoing shoulder surgery to provide continuous monitoring of cerebral oxygenation. In both protocols, the improved depth sensitivity of trNIRS was investigated by applying moment analysis. A dynamic wavelet filtering approach was also developed to remove observed temperature-induced signal drifts. Results: In the first protocol (28±5 years; five females, five males), hair significantly impacted regional sensitivity; however, the enhanced depth sensitivity of trNIRS was able to separate brain and scalp responses in the frontal region. Regional sensitivity was improved in the clinical study given the age-related reduction in hair density of the patients (65±15 years; 14 females, 13 males). In five patients who received phenylephrine to treat hypotension, different scalp and brain oxygenation responses were apparent, although no regional differences were observed. Conclusions: The Kernel Flow has promise as an intraoperative neuromonitoring device. Although regional sensitivity was affected by hair color and density, enhanced depth sensitivity of trNIRS was able to resolve differences in scalp and brain oxygenation responses in both protocols.


Asunto(s)
Circulación Cerebrovascular , Espectroscopía Infrarroja Corta , Humanos , Espectroscopía Infrarroja Corta/métodos , Espectroscopía Infrarroja Corta/instrumentación , Femenino , Masculino , Adulto , Circulación Cerebrovascular/fisiología , Hemodinámica/fisiología , Oximetría/métodos , Oximetría/instrumentación , Oxígeno/sangre , Oxígeno/metabolismo , Encéfalo/diagnóstico por imagen , Encéfalo/irrigación sanguínea , Diseño de Equipo
10.
J Vis Exp ; (207)2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38801263

RESUMEN

The detection of levels of impairment in microvascular oxygen consumption and reactive hyperemia is vital in critical care. However, there are no practical means for a robust and quantitative evaluation. This paper describes a protocol to evaluate these impairments using a hybrid near-infrared diffuse optical device. The device contains modules for near-infrared time-resolved and diffuse correlation spectroscopies and pulse-oximetry. These modules allow the non-invasive, continuous, and real-time measurement of the absolute, microvascular blood/tissue oxygen saturation (StO2) and the blood flow index (BFI) along with the peripheral arterial oxygen saturation (SpO2). This device uses an integrated, computer-controlled tourniquet system to execute a standardized protocol with optical data acquisition from the brachioradialis muscle. The standardized vascular occlusion test (VOT) takes care of the variations in the occlusion duration and pressure reported in the literature, while the automation minimizes inter-operator differences. The protocol we describe focuses on a 3-min occlusion period but the details described in this paper can readily be adapted to other durations and cuff pressures, as well as other muscles. The inclusion of an extended baseline and post-occlusion recovery period measurement allows the quantification of the baseline values for all the parameters and the blood/tissue deoxygenation rate that corresponds to the metabolic rate of oxygen consumption. Once the cuff is released, we characterize the tissue reoxygenation rate, magnitude, and duration of the hyperemic response in BFI and StO2. These latter parameters correspond to the quantification of the reactive hyperemia, which provides information about the endothelial function. Furthermore, the above-mentioned measurements of the absolute concentration of oxygenated and deoxygenated hemoglobin, BFI, the derived metabolic rate of oxygen consumption, StO2, and SpO2 provide a yet-to-be-explored rich data set that can exhibit disease severity, personalized therapeutics, and management interventions.


Asunto(s)
Cuidados Críticos , Hiperemia , Espectroscopía Infrarroja Corta , Espectroscopía Infrarroja Corta/métodos , Hiperemia/metabolismo , Humanos , Cuidados Críticos/métodos , Oxígeno/metabolismo , Oxígeno/sangre , Consumo de Oxígeno/fisiología , Oximetría/métodos , Oximetría/instrumentación , Músculo Esquelético/metabolismo , Músculo Esquelético/irrigación sanguínea , Microcirculación/fisiología , Microvasos/metabolismo , Saturación de Oxígeno/fisiología
11.
Med Sci Sports Exerc ; 56(9): 1585-1594, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38635406

RESUMEN

PURPOSE: The purpose of this study was to evaluate the accuracy of peripheral oxygen saturation (SpO 2 ) measurements from Polar Elixir™ pulse oximetry technology compared with arterial oxygen saturation (SaO 2 ) measurements during acute stepwise steady-state inspired hypoxia at rest. A post hoc objective was to determine if SpO 2 measurements could be improved by recalibrating the Polar Elixir™ algorithm with SaO 2 values from a random subset of participants. METHODS: The International Organization for Standardization (ISO) protocol (ISO 80601-2-61:2017) for evaluating the SpO 2 accuracy of pulse oximeter equipment was followed whereby five plateaus of SaO 2 between 70% and 100% were achieved using stepwise reductions in inspired O 2 during supine rest. Blood samples drawn through a radial arterial catheter from 25 participants were first used to compare SaO 2 with SpO 2 measurements from Polar Elixir™. Then the Polar Elixir™ algorithm was recalibrated using SaO 2 data from 13 random participants, and SpO 2 estimates were recalculated for the other 12 participants. For SaO 2 values between 70% and 100%, root mean square error, intraclass correlation coefficients (ICC), Pearson correlations, and Bland-Altman plots were used to assess the accuracy, agreement, and strength of relationship between SaO 2 values and SpO 2 values from Polar Elixir™. RESULTS: The initial root mean square error for Polar Elixir™ was 4.13%. After recalibrating the algorithm, the RMSE was improved to 2.67%. The ICC revealed excellent levels of agreement between SaO 2 and Polar Elixir™ SpO 2 values both before (ICC(1,3) = 0.837, df = 574, P < 0.001) and after (ICC(1,3) = 0.942, df = 287, P < 0.001) recalibration. CONCLUSIONS: Relative to ISO standards, Polar Elixir™ yielded accurate SpO 2 measurements during stepwise inspired hypoxia at rest when compared with SaO 2 values, which were improved by recalibrating the algorithm using a subset of the SaO 2 data.


Asunto(s)
Algoritmos , Hipoxia , Oximetría , Saturación de Oxígeno , Humanos , Oximetría/instrumentación , Oximetría/métodos , Masculino , Hipoxia/sangre , Femenino , Saturación de Oxígeno/fisiología , Adulto , Análisis de los Gases de la Sangre/instrumentación , Análisis de los Gases de la Sangre/métodos , Adulto Joven , Oxígeno/sangre , Calibración
13.
Pediatr Res ; 96(2): 486-493, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38503982

RESUMEN

BACKGROUND: Unstable cerebral hemodynamics places preterm infants at high risk of brain injury. We adapted an innovative, fiber-free, wearable diffuse speckle contrast flow-oximetry (DSCFO) device for continuous monitoring of both cerebral blood flow (CBF) and oxygenation in neonatal piglets and preterm infants. METHODS: DSCFO uses two small laser diodes as focused-point and a tiny CMOS camera as a high-density two-dimensional detector to detect spontaneous spatial fluctuation of diffuse laser speckles for CBF measurement, and light intensity attenuations for cerebral oxygenation measurement. The DSCFO was first validated against the established diffuse correlation spectroscopy (DCS) in neonatal piglets and then utilized for continuous CBF and oxygenation monitoring in preterm infants during intermittent hypoxemia (IH) events. RESULTS: Significant correlations between the DSCFO and DCS measurements of CBF variations in neonatal piglets were observed. IH events induced fluctuations in CBF, cerebral oxygenation, and peripheral cardiorespiratory vitals in preterm infants. However, no consistent correlation patterns were observed among peripheral and cerebral monitoring parameters. CONCLUSIONS: This pilot study demonstrated the feasibility of DSCFO technology to serve as a low-cost wearable sensor for continuous monitoring of multiple cerebral hemodynamic parameters. The results suggested the importance of multi-parameter measurements for understanding deep insights of peripheral and cerebral regulations. IMPACT: The innovative DSCFO technology may serve as a low-cost wearable sensor for continuous bedside monitoring of multiple cerebral hemodynamic parameters in neonatal intensive care units. Concurrent DSCFO and DCS measurements of CBF variations in neonatal piglet models generated consistent results. No consistent correlation patterns were observed among peripheral and cerebral monitoring parameters in preterm neonates, suggesting the importance of multi-parameter measurements for understanding deep insights of peripheral and cerebral regulations during IH events. Integrating and correlating multiple cerebral functional parameters with clinical outcomes may identify biomarkers for prediction and management of IH associated brain injury.


Asunto(s)
Animales Recién Nacidos , Circulación Cerebrovascular , Oximetría , Oxígeno , Dispositivos Electrónicos Vestibles , Animales , Recién Nacido , Humanos , Porcinos , Oximetría/instrumentación , Oximetría/métodos , Oxígeno/metabolismo , Oxígeno/sangre , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Proyectos Piloto , Recien Nacido Prematuro , Hemodinámica , Hipoxia , Femenino , Masculino , Encéfalo/irrigación sanguínea
14.
J Anesth ; 38(3): 364-370, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38502324

RESUMEN

PURPOSE: Though the finger is generally recommended for pulse oxygen saturation (SpO2) monitoring site, its reliability may be compromised in conditions of poor peripheral perfusion. Therefore, we compared the performance of nasal septum SpO2 monitoring with finger SpO2 monitoring relative to simultaneous arterial oxygen saturation (SaO2) monitoring in generally anesthetized patients. METHODS: In 23 adult patients, comparisons of SpO2 measured at the nasal septum and finger with simultaneous SaO2 were made at four time points during the 90 min study period. A pulse oximetry monitoring failure was defined as a > 10 s continuous failure of in an adequate SpO2 data acquisition. Core temperature as well as finger-tip and nasal septum temperatures were simultaneously measured at 10 min intervals. RESULTS: A total of 92 sets of SpO2 and SaO2 measurements were obtained in 23 patients. The bias and precision for SpO2 measured at the nasal septum were - 0.8 ± 1.3 (95% confidence interval: - 1.1 to - 0.6), which was similar to those for SpO2 measured at the finger (- 0.6 ± 1.4; 95% confidence interval: - 0.9 to - 0.4) (p = 0.154). Finger-tip temperatures were consistently lower than other two temperatures at all time points (p < 0.05), reaching 33.5 ± 2.3 °C at 90 min after induction of anesthesia. While pulse oximetry monitoring failure did not occur for nasal septum probe, two cases of failure occurred for finger probe. CONCLUSIONS: Considering the higher stability to hypothermia with a similar accuracy, nasal septum pulse oximetry may be an attractive alternative to finger pulse oximetry. Trail registration This study was registered with Clinical Research Information Service (CRIS: https://cris.nih.go.kr/cris/en/ ; ref: KCT0008352).


Asunto(s)
Anestesia General , Dedos , Tabique Nasal , Oximetría , Saturación de Oxígeno , Humanos , Oximetría/métodos , Oximetría/instrumentación , Dedos/irrigación sanguínea , Masculino , Femenino , Anestesia General/métodos , Persona de Mediana Edad , Tabique Nasal/cirugía , Adulto , Saturación de Oxígeno/fisiología , Temperatura Corporal/fisiología , Monitoreo Intraoperatorio/métodos , Monitoreo Intraoperatorio/instrumentación , Anciano , Reproducibilidad de los Resultados , Oxígeno/sangre
15.
Anesth Analg ; 139(1): 220-225, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38195082

RESUMEN

BACKGROUND: Operating room (OR) expenditures and waste generation are a priority, with several professional societies recommending the use of reprocessed or reusable equipment where feasible. The aim of this analysis was to compare single-use pulse oximetry sensor stickers ("single-use stickers") versus reusable pulse oximetry sensor clips ("reusable clips") in terms of annual cost savings and waste generation across all ORs nationally. METHODS: This study did not involve patient data or research on human subjects. As such, it did not meet the requirements for institutional review board approval. An economic model was used to compare the relative costs and waste generation from using single-use stickers versus reusable clips. This model took into account: (1) the relative prices of single-use stickers and reusable clips, (2) the number of surgeries and ORs nationwide, (3) the workload burden of cleaning the reusable clips, and (4) the costs of capital for single-use stickers and reusable clips. In addition, we also estimated differences in waste production based on the raw weight plus unit packaging of single-use stickers and reusable clips that would be disposed of over the course of the year, without any recycling interventions. Estimated savings were rounded to the nearest $0.1 million. RESULTS: The national net annual savings of transitioning from single-use stickers to reusable clips in all ORs ranged from $510.5 million (conservative state) to $519.3 million (favorable state). Variability in savings estimates is driven by scenario planning for replacement rate of reusable clips, workload burden of cleaning (ranging from an additional expense of $618k versus a cost savings of $309k), and cost of capital-interest gained on investment of capital that is freed up by the monetary savings of a transition to reusable clips contributes between $541k (low-interest rates of 2.85%) and $1.3 million (high-interest rates of 7.08%). The annual waste that could be diverted from landfill by transitioning to reusable clips was found to be between 587 tons (conservative state) up to 589 tons (favorable state). If institutions need to purchase new vendor monitors or cables to make the transition, that may increase the 1-time capital disbursement. CONCLUSIONS: Using reusable clips versus single-use stickers across all ORs nationally would result in appreciable annual cost savings and waste generation reduction impact. As both single-use stickers and reusable clips are equally accurate and reliable, this cost and waste savings could be instituted without a compromise in clinical care.


Asunto(s)
Ahorro de Costo , Equipos Desechables , Equipo Reutilizado , Quirófanos , Oximetría , Quirófanos/economía , Oximetría/economía , Oximetría/instrumentación , Equipo Reutilizado/economía , Humanos , Estados Unidos , Equipos Desechables/economía , Modelos Económicos , Costos de Hospital
16.
Am J Perinatol ; 41(12): 1736-1742, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38272062

RESUMEN

OBJECTIVE: Cerebral oximetry using near-infrared spectroscopy (NIRS) is a noninvasive optical technology widely used in neonatology. The present study aimed to define reference ranges for cerebral tissue oxygen saturation (crSO2) with a new four-wavelength NIRS device, Masimo O3 oximeter, during immediate transition after birth and compare values with those obtained previously with NIRO 200NX®. STUDY DESIGN: This was a prospective observational study using Masimo O3 device to measure crSO2 and regional cerebral fractional tissue oxygen extraction (cFTOE) in healthy term newborns delivered by primary cesarean section, during the 15 minutes after cord clamping. The neonates who required any medical support were excluded. The NIRS sensor was placed on the right forehead. Peripheral oxygen saturation and heart rate were continuously measured by pulse oximetry. Previous studies which established centiles for crSO2 with NIRO 200NX were used for comparison. RESULTS: A total of 44 newborns were included. The median crSO2 and cFTOE (interquartile range) at 2, 5, and 7 minutes was 54% (49-54), 71% (64-86), and 79% (73-84) and 0,25 (0,18-0,33), 0,19 (0,15-0,23), and 0,16 (0,12-0,21), respectively, with no further changes afterwards. The crSO2 measurements were significantly higher with Masimo O3 compared with NIRO-200NX. CONCLUSION: The present observational study presented reference ranges for crSO2 and cFTOE measured with Masimo O3 oximeter during the immediate neonatal transition. Values obtained with O3 were higher than those obtained with other oximeters. For this reason, crSO2 is device-specific so there must be known reference values for each oximeter to define therapeutic interventions based on crSO2 and assess cerebral oxygenation in clinical studies. KEY POINTS: · Masimo O3 uses four wavelengths to measure regional oxygen saturation value.. · O3 values of crSO2 and cFTOE differ with other neonatal oximeters at birth.. · Knowledge of reference range of O3 at birth is essential to guide resuscitation..


Asunto(s)
Oximetría , Saturación de Oxígeno , Espectroscopía Infrarroja Corta , Humanos , Recién Nacido , Estudios Prospectivos , Oximetría/instrumentación , Oximetría/métodos , Femenino , Valores de Referencia , Masculino , Encéfalo/metabolismo , Oxígeno/sangre , Oxígeno/metabolismo , Cesárea
17.
J Strength Cond Res ; 38(5): 873-880, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38241480

RESUMEN

ABSTRACT: Vehrs, PR, Reynolds, S, Allen, J, Barrett, R, Blazzard, C, Burbank, T, Hart, H, Kasper, N, Lacey, R, Lopez, D, and Fellingham, GW. Measurements of arterial occlusion pressure using hand-held devices. J Strength Cond Res 38(5): 873-880, 2024-Arterial occlusion pressure (AOP) of the brachial artery was measured simultaneously using Doppler ultrasound (US), a hand-held Doppler (HHDOP), and a pulse oximeter (PO) in the dominant (DOM) and nondominant (NDOM) arms of males ( n = 21) and females ( n = 23) using continuous (CONT) and incremental (INCR) cuff inflation protocols. A mixed-model analysis of variance revealed significant ( p < 0.05) overall main effects between AOP measured using a CONT (115.7 ± 10.9) or INCR (115.0 ± 11.5) cuff inflation protocol; between AOP measured using US (116.3 ± 11.2), HHDOP (115.4 ± 11.2), and PO (114.4 ± 11.2); and between males (120.7 ± 10.6) and females (110.5 ± 9.4). The small overall difference (1.81 ± 3.3) between US and PO measures of AOP was significant ( p < 0.05), but the differences between US and HHDOP and between HHDOP and PO measures of AOP were not significant. There were no overall differences in AOP between the DOM and NDOM arms. Trial-to-trial variance in US measurements of AOP was not significant when using either cuff inflation protocol but was significant when using HHDOP and PO and a CONT cuff inflation protocol. Bland-Altman plots revealed reasonable limits of agreement for both HHDOP and PO measures of AOP. The small differences in US, HHDOP, and PO measurements of AOP when using CONT or INCR cuff inflation protocols are of minimal practical importance. The choice of cuff inflation protocol is one of personal preference. Hand-held Doppler of PO can be used to assess AOP before using blood flow restriction during exercise.


Asunto(s)
Arteria Braquial , Ultrasonografía Doppler , Humanos , Masculino , Femenino , Arteria Braquial/fisiología , Arteria Braquial/diagnóstico por imagen , Adulto , Adulto Joven , Oximetría/instrumentación
18.
Rev. Ciênc. Plur ; 9(3): 31585, 26 dez. 2023. tab, ilus
Artículo en Portugués | LILACS, BBO - Odontología | ID: biblio-1524449

RESUMEN

Introdução:A oximetria de pulso neonatal compõe o Programa Nacional de Triagem Neonatal do Brasil desde 2014. Entretanto, existem poucos registros de sua efetiva implementação na rotina de cuidados materno-infantis no país.Objetivo:O objetivo deste trabalho foi relatar a experiência em ações de educação em saúde a profissionais e estudantes da área da saúde e à população em geral, em temas relacionados ao Teste do Coraçãozinho.Metodologia:Trata-se de um estudo descritivo, do tipo relato de experiência, executado entre julho de 2019 a julho de 2021, antes e durante a pandemia de Covid-19, por discentes vinculados ao projeto de extensão de serviço universitário de referência do Rio Grande do Norte. O público-alvo das capacitações foram estudantes e profissionais do curso de Medicina, Enfermagem e Técnico de Enfermagem dos municípios de Natal, Macaíba, Santa Cruz, Currais Novos, Mossoró e Caicó, do estado do Rio Grande do Norte. Foi realizada uma capacitação no formato presencial antes da pandemia causada pela COVID-19 ou no formato remoto como adaptação das atividades durante o período pandêmico. A metodologia dos treinamentos foi composta por um formulário de pré e pós teste visando avaliar a eficácia das capacitações, somado a fundamentação teórica, simulações teórico-práticas e discussão de casos clínicos. Além disso, foram promovidas ações educativas destinadas à população geral. Resultados:As capacitações ministradas a profissionais e estudantes da área da saúde totalizaram 1212 participantes. Os eventos direcionados ao meio externo, como transmissões ao vivo e conteúdos audiovisuais em redes sociais, atingiram 12.931 pessoas. O fomento à produção científica envolveu a elaboração de 95 trabalhos aprovados em congressos regionais, nacionais e internacionais, bem como a organização de um congresso internacional nas áreas de Pediatria e Cardiologia, contabilizando 29.007 inscritos.Conclusões:Evidenciou-se a importância de intervenções para melhoria da linha de cuidado à criança cardiopata (AU).


Introduction:Neonatal pulse oximetry has been part of the National Newborn Screening Program in Brazil since 2014. However, there are few reports of its effective implementation in routine maternal and child care in the country. Objective: This study reports on the experience of providing health education to health professionals, students and the general population on topics related to neonatal pulse oximetry.Methodology: This is a descriptive study, experience report type, carried out between July 2019 and July 2021,before and during the Covid-19 pandemic, by students linked to the extension project of a reference university service in Rio Grande do Norte. The target audience of the training were students and professionals from the Medicine, Nursing and Nursing Technician course in the municipalities of Natal, Macaíba, Santa Cruz, Currais Novos, Mossoró and Caicó, in the state of Rio Grande do Norte. Training was carried out in person before the COVID-19 pandemic or remotely as an adaptation of activities during the pandemic period. The training methodology consisted of a pre-and post-test form aimed at evaluating the effectiveness of the training, in addition to theoretical foundations, theoretical-practical simulations and discussion of clinical cases. In addition, educational activities were promoted for the general population.Results:Training given to health professionals and students totaled 1212 participants. Events directed to the external environment, such as live broadcasts and audiovisual content on socialnetworks, reached 12,931 people. Promotion of scientific production involved the preparation of 95 papers approved in regional, national, and international congresses, as well as the organization of an international congress in the areas of Pediatrics andCardiology, with 29,007 registered participants. Conclusions: The importance of interventions to improve the line of care for children with heart disease was evidenced (AU).


Introducción: La oximetría de pulso neonatal forma parte del Programa Nacional de Tamizaje Neonatal en Brasil desde 2014. Sin embargo, existen pocos registros de su implementación efectiva en la atención materno-infantil de rutina en el país. Objetivo: El objetivo de este trabajo fue relatar la experiencia en acciones de educación en salud para profesionales y estudiantes del área de la salud y la población en general, sobre temas relacionados con El Test del Corazoncito. Metodología:Se trata de un estudiodescriptivo, del tipo relato de experiencia, realizado entre julio de 2019 y julio de 2021, antes y durante la pandemia de la Covid-19, por estudiantes vinculados al proyecto de extensión de un servicio universitario de referencia en Rio Grande Norte. El público objetivo de la capacitación fueron estudiantes y profesionales de la carrera de Medicina, Enfermería y Técnico en Enfermería de los municipios de Natal, Macaíba, Santa Cruz, Currais Novos, Mossoró y Caicó, en el estado de Rio Grande do Norte. La formación se realizó en formato presencial antes de la pandemia causada por el COVID-19 o a distancia como adaptación de las actividades durante el periodo de pandemia. La metodología de capacitación consistió en un formulario de pre y post test dirigido a evaluar la efectividad de la capacitación, además de fundamentos teóricos, simulacros teórico-prácticos y discusión de casos clínicos. Además, se promovieron actividades educativas para la población en general. Resultados:La formación impartida a profesionales y estudiantes de la salud totalizó 1212 participantes. Los eventos dirigidos al entorno externo, como retransmisiones en directo y contenidos audiovisuales en redes sociales, llegaron a 12.931 personas. El fomento de la producción científica implicó la elaboración de 95 trabajos aprobados en congresos regionales, nacionales e internacionales, así como la organización de un congreso internacional en las áreas de Pediatría y Cardiología, con 29.007 inscritos. Conclusiones:Se destacó la importancia de las intervenciones para mejorar la línea de atención a los niños con cardiopatías (AU).


Asunto(s)
Humanos , Masculino , Femenino , Oximetría/instrumentación , Educación en Salud , Aprendizaje Basado en Problemas/métodos , Estudiantes del Área de la Salud , Epidemiología Descriptiva
SELECCIÓN DE REFERENCIAS