Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.571
Filtrar
1.
BMC Oral Health ; 24(1): 501, 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38725023

RESUMEN

BACKGROUND: Releasing of metal ions might implicate in allergic reaction as a negative subsequent of the corrosion of Stainless Steel (SS304) orthodontic wires. The aim of this study was to evaluate the corrosion resistance of zinc-coated (Zn-coated) SS orthodontic wires. METHODS: Zinc coating was applied on SS wires by PVD method. Electrochemical impedance spectroscopy (EIS), Potentiodynamic polarization tests and Tafel analysis methods were used to predict the corrosion behavior of Zn-coated and uncoated SS wires in both neutral and acidic environments. RESULTS: The values of Ecorr ,icorr and Rct ,which were the electrochemical corrosion characteristics, reported better corrosion behavior of Zn-coated SS wires against uncoated ones in both artificial saliva and fluoride-containing environments. Experimental results of the Tafel plot analyses were consistent with that of electrochemical impedance spectroscopy analyses for both biological solutions. CONCLUSION: Applying Zn coating on bare SS orthodontic wire by PVD method might increase the corrosion resistance of the underlying stainless-steel substrate.


Asunto(s)
Espectroscopía Dieléctrica , Ensayo de Materiales , Alambres para Ortodoncia , Saliva Artificial , Acero Inoxidable , Zinc , Corrosión , Acero Inoxidable/química , Zinc/química , Saliva Artificial/química , Aleaciones Dentales/química , Materiales Biocompatibles Revestidos/química , Fluoruros/química , Concentración de Iones de Hidrógeno , Humanos , Propiedades de Superficie , Potenciometría
2.
Anal Chim Acta ; 1306: 342615, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38692795

RESUMEN

The Caco-2 cells were used as intestinal epithelial cell model to illustrate the hyperuricemia (HUA) mechanism under the co-culture of the imbalanced intestinal microbiome in this work. The uric acid (UA) concentration in the HUA process was monitored, and could be up to 425 µmol/L at 8 h co-cultured with the imbalanced intestinal microbiome. Single-cell potentiometry based on ion-selective microelectrode was used to study extracellular calcium change, which is hypothesized to play an important role in the UA excretion. The potential signal of the calcium in the extremely limited microenvironment around single Caco-2 cell was recorded through the single-cell analysis platform. The potential signal of sharp decrease and slow increase followed within a few seconds indicates the sudden uptake and gradually excretion process of calcium through the cell membrane. Moreover, the value of the potential decrease increases with the increase of the time co-cultured with the imbalanced intestinal microbiome ranging from 0 to 8 h. The Ca2+ concentration around the cell membrane could decrease from 1.3 mM to 0.4 mM according to the potential decrease of 27.0 mV at the co-culture time of 8 h. The apoptosis ratio of the Caco-2 cells also exhibits time dependent with the co-culture of the imbalanced intestinal microbiome, and was 39.1 ± 3.6 % at the co-culture time of 8 h, which is much higher than the Caco-2 cells without any treatment (3.9 ± 2.9 %). These results firstly provide the links between the UA excretion with the apoptosis of the intestinal epithelial cell under the interaction of the imbalanced intestinal microbiome. Moreover, the apoptosis could be triggered by the calcium signaling.


Asunto(s)
Calcio , Carbono , Técnicas de Cocultivo , Microbioma Gastrointestinal , Microelectrodos , Potenciometría , Análisis de la Célula Individual , Humanos , Células CACO-2 , Calcio/metabolismo , Carbono/química , Apoptosis
3.
Mikrochim Acta ; 191(6): 313, 2024 05 08.
Artículo en Inglés | MEDLINE | ID: mdl-38717608

RESUMEN

Copper levels in biological fluids are associated with Wilson's, Alzheimer's, Menke's, and Parkinson's diseases, making them good biochemical markers for these diseases. This study introduces a miniaturized screen-printed electrode (SPE) for the potentiometric determination of copper(II) in some biological fluids. Manganese(III) oxide nanoparticles (Mn2O3-NPs), dispersed in Nafion, are drop-casted onto a graphite/PET substrate, serving as the ion-to-electron transducer material. The solid-contact material is then covered by a selective polyvinyl chloride (PVC) membrane incorporated with 18-crown-6 as a neutral ion carrier for the selective determination of copper(II) ions. The proposed electrode exhibits a Nernstian response with a slope of 30.2 ± 0.3 mV/decade (R2 = 0.999) over the linear concentration range 5.2 × 10-9 - 6.2 × 10-3 mol/l and a detection limit of 1.1 × 10-9 mol/l (69.9 ng/l). Short-term potential stability is evaluated using constant current chronopotentiometry (CP) and electrochemical impedance spectroscopy (EIS). A significant improvement in the electrode capacitance (91.5 µF) is displayed due to the use of Mn2O3-NPs as a solid contact. The presence of Nafion, with its high hydrophobicity properties, eliminates the formation of the thin water layer, facilitating the ion-to-electron transduction between the sensing membrane and the conducting substrate. Additionally, it enhances the adhesion of the polymeric sensing membrane to the solid-contact material, preventing membrane delamination and increasing the electrode's lifespan. The high selectivity, sensitivity, and potential stability of the proposed miniaturized electrode suggests its use for the determination of copper(II) ions in human blood serum and milk samples. The results obtained agree fairly well with data obtained by flameless atomic absorption spectrometry.


Asunto(s)
Cobre , Éteres Corona , Electrodos , Polímeros de Fluorocarbono , Límite de Detección , Compuestos de Manganeso , Óxidos , Potenciometría , Cobre/química , Polímeros de Fluorocarbono/química , Óxidos/química , Compuestos de Manganeso/química , Humanos , Potenciometría/instrumentación , Potenciometría/métodos , Éteres Corona/química , Grafito/química
4.
Sci Rep ; 14(1): 11526, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38773136

RESUMEN

This paper reports on the development of a flexible-wearable potentiometric sensor for real-time monitoring of sodium ion (Na+), potassium ion (K+), and pH in human sweat. Na0.44MnO2, polyaniline, and K2Co[Fe(CN)6] were used as sensing materials for Na+, H+ and K+ monitoring, respectively. The simultaneous potentiometric Na+, K+, and pH sensing were carried out by the developed sensor, which enables signal collection and transmission in real-time to the smartphone via a Wi-Fi access point. Then, the potentiometric responses were evaluated by a designed android application. Na+, K+, and pH sensors illustrated high sensitivity (59.7 ± 0.8 mV/decade for Na+, 57.8 ± 0.9 mV/decade for K+, and 54.7 ± 0.6 mV/pH for pH), excellent stability, and good batch-to-batch reproducibility. The results of on-body experiments demonstrated that the proposed platform is capable of real-time monitoring of the investigated ions.


Asunto(s)
Potasio , Potenciometría , Sodio , Sudor , Dispositivos Electrónicos Vestibles , Humanos , Concentración de Iones de Hidrógeno , Potenciometría/métodos , Potenciometría/instrumentación , Sodio/análisis , Sudor/química , Potasio/análisis , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Tecnología Inalámbrica/instrumentación , Teléfono Inteligente , Reproducibilidad de los Resultados
5.
Int J Biol Macromol ; 268(Pt 1): 131598, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38621570

RESUMEN

The present work demonstrates the correlation between structure, properties, and self-sensing protocols of in situ prepared ferric oxide doped grafted copolymer composite, comprised of ferric oxide, chitosan, and polypyrrole (α-Fe2O3-en-CHIT-g-PPy) for residual ibuprofen present in natural and artificial samples. The chemical structure, morphology, functionality, and physio-mechanical properties of the composite were determined by Fourier transform infrared spectrometer (FT-IR), Raman spectra, X-ray diffraction (XRD), Scanning electron microscope (SEM), X-ray photoelectron spectroscopy (XPS), Two probe method, and standard ASTM techniques to explore sensing nature. The results confirm the evolution of axially aligned structure against 110 planes of α-Fe2O3 and chemically functionalized expanded polymer matrix during in-situ chemical polymerization of pyrrole, with better porosity, interactivity, and improved electrical conductivity i.e. 7.32 × 10-3 S cm-1. Further, a thin film of prepared composite coated on an ITO glass plate was explored for potentiometric sensing of ibuprofen (IBU) present in artificial and natural samples without the use of any additional energy sources. The observed sensing parameters are the sensing ranging 0.5 µM to 100.0 µM, sensitivity 2.5081 mV µM-1 cm-2, response time 50 s, recovery time 10 s, and stability for 60 days. The sensing mechanism of the IBU sensor and effective charge transfer in the electrode was also discussed based on changes in IR spectra of the electrode recorded before and after sensing due to surface oxidation of IBU due to the presence of iron and doping effect of iron oxide in the composite.


Asunto(s)
Quitosano , Electrodos , Compuestos Férricos , Ibuprofeno , Polímeros , Potenciometría , Pirroles , Quitosano/química , Pirroles/química , Ibuprofeno/química , Ibuprofeno/análisis , Polímeros/química , Compuestos Férricos/química , Potenciometría/métodos , Espectroscopía Infrarroja por Transformada de Fourier
6.
Int J Mol Sci ; 25(8)2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38673999

RESUMEN

E. coli nitroreductase A (NfsA) is a candidate for gene-directed prodrug cancer therapy using bioreductively activated nitroaromatic compounds (ArNO2). In this work, we determined the standard redox potential of FMN of NfsA to be -215 ± 5 mV at pH 7.0. FMN semiquinone was not formed during 5-deazaflavin-sensitized NfsA photoreduction. This determines the two-electron character of the reduction of ArNO2 and quinones (Q). In parallel, we characterized the oxidant specificity of NfsA with an emphasis on its structure. Except for negative outliers nitracrine and SN-36506, the reactivity of ArNO2 increases with their electron affinity (single-electron reduction potential, E17) and is unaffected by their lipophilicity and Van der Waals volume up to 386 Å. The reactivity of quinoidal oxidants is not clearly dependent on E17, but 2-hydroxy-1,4-naphthoquinones were identified as positive outliers and a number of compounds with diverse structures as negative outliers. 2-Hydroxy-1,4-naphthoquinones are characterized by the most positive reaction activation entropy and the negative outlier tetramethyl-1,4-benzoquinone by the most negative. Computer modelling data showed that the formation of H bonds with Arg15, Arg133, and Ser40, plays a major role in the binding of oxidants to reduced NfsA, while the role of the π-π interaction of their aromatic structures is less significant. Typically, the calculated hydride-transfer distances during ArNO2 reduction are smallwer than for Q. This explains the lower reactivity of quinones. Another factor that slows down the reduction is the presence of positively charged aliphatic substituents.


Asunto(s)
Proteínas de Escherichia coli , Escherichia coli , Nitrorreductasas , Oxidación-Reducción , Profármacos , Nitrorreductasas/metabolismo , Nitrorreductasas/química , Nitrorreductasas/genética , Profármacos/química , Profármacos/metabolismo , Especificidad por Sustrato , Escherichia coli/genética , Proteínas de Escherichia coli/metabolismo , Proteínas de Escherichia coli/química , Proteínas de Escherichia coli/genética , Potenciometría , Catálisis , Simulación del Acoplamiento Molecular
7.
J Colloid Interface Sci ; 668: 223-231, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38677211

RESUMEN

The sandwich approach, whereby an antigen is captured by a primary antibody and detected by a secondary antibody, is commonly used to improve the selectivity and sensitivity of enzyme-linked immunosorbent assays (ELISA). This work details the experimental factors that impact the reliable translation of this sandwich approach to two commonly used electronic biosensors, namely potentiometric and impedimetric biosensors. Previous studies have demonstrated the Debye screening limitations associated with potentiometric biosensors. However, the correlation between the ionic strength of the measurement buffer and the impedimetric biosensing response has not been studied. Potentiometric biosensors were able to successfully detect the primary antibody and the target antigen by decreasing the ionic strength of the phosphate buffered saline (PBS) measurement buffer from 1x PBS to 0.01x PBS. However, the secondary antibody used for the selective signal amplification was not reliably detected. Therefore, the sandwich approach is not viable for potentiometric sensing at biologically relevant ionic strengths, due to the Debye screening effect. Alternatively, decreasing the ionic strength of the measurement buffer allowed for the successful translation of the sandwich approach to impedimetric biosensors. Impedimetric biosensing literature typically attributes a measured increase in the charge transfer resistance to an increase in the thickness of the immobilized biolayer. However, this work highlights the influence that both the charge and thickness of the biolayer have on the transport of the redox couple. Decreasing the ionic strength of the measurement buffer lowers the molecular charge screening effect. This permits the transport of a positively charged redox probe through a negatively charged immobilized biolayer via migration and diffusion. The results demonstrate that the use of a buffer at a lower, yet biologically relevant ionic strength allows for the successful translation of the sandwich approach to impedimetric biosensors.


Asunto(s)
Técnicas Biosensibles , Ensayo de Inmunoadsorción Enzimática , Técnicas Biosensibles/métodos , Concentración Osmolar , Potenciometría/métodos
8.
Anal Chim Acta ; 1294: 342282, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38336415

RESUMEN

BACKGROUND: Ionic calcium (Ca2+) plays a crucial role in maintaining normal physiological and biochemical functions within the human body. Detecting the concentration of Ca2+ is of utmost significance for various purposes, including disease screening, cellular metabolism research, and evaluating drug effectiveness. However, current detection approaches such as fluorescence and colorimetry face limitations due to complex labeling techniques and the inability to track changes in Ca2+ concentration. In recent years, extensive research has been conducted in this field to explore label-free and efficient approaches. RESULTS: In this study, a novel light-addressed potentiometric sensor (LAPS) using silicon-on-sapphire technology, has been successfully developed for Ca2+ sensing. The Ca2+-sensitive LAPS achieved a wide-range detection of Ca2+, ranging from 10-2 M to 10-7 M, with an impressive detection limit of 100 nM. These advancements are attributed to the ultra-thin silicon layer, silicon dioxide layer, and solid-state silicon rubber sensitive membrane around 6 µm. Furthermore, the sensor demonstrated the ability to dynamically monitor fluctuations in Ca2+ concentration ranging from 10-9 M to 10-2 M within a solution. Its remarkable selectivity, specificity, and long-term stability have facilitated its successful application in the detection of Ca2+ in human serum and urine. SIGNIFICANCE AND NOVELTY: This work presents a Ca2+-sensitive sensor that combines a low detection limit and a wide detection range. The development represents the emergence of a label-free and rapid Ca2+ detection tool with immense prospects in home-based health monitoring, community disease screening, as well as cellular metabolism, and drug screening evaluations.


Asunto(s)
Óxido de Aluminio , Técnicas Biosensibles , Humanos , Calcio , Luz , Técnicas Biosensibles/métodos , Potenciometría/métodos , Iones
9.
Analyst ; 149(6): 1738-1745, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38324339

RESUMEN

Carrier-based polymeric membrane potentiometric sensors are an ideal tool for detecting ionic species. However, in the fabrication of these sensors, the screening of carriers still relies on empirical trial- and error-based optimization, which requires tedious and time-consuming experimental verification. In this work, computer-aided screening of carriers is applied in the preparation of polymeric membrane potentiometric sensors. Molecular docking is used to study the host-guest interactions between receptors and targets. Binding energies are employed as the standard to screen the appropriate carrier. As a proof-of-concept experiment, the antibiotic ciprofloxacin is selected as the target model. A series of supramolecular macrocyclic receptors including cyclodextrins, cucurbiturils and calixarenes are chosen as potential receptors. The proposed sensor based on the receptor calix[4]arene screened by molecular docking shows a lower detection limit of 0.5 µmol L-1 for ciprofloxacin. It can be expected that the proposed computer-aided screening technique of carriers can provide a simple but highly efficient method for the fabrication of carrier-based electrochemical and optical sensors.


Asunto(s)
Calixarenos , Compuestos Macrocíclicos , Antibacterianos , Simulación del Acoplamiento Molecular , Potenciometría , Compuestos Macrocíclicos/química , Polímeros/química , Calixarenos/química , Ciprofloxacina
10.
Mikrochim Acta ; 191(3): 128, 2024 02 09.
Artículo en Inglés | MEDLINE | ID: mdl-38334814

RESUMEN

A paper-based analytical device (PAD) with an integrated composite electrode has been designed and fabricated for non-enzymatic creatinine sensing. Reduced graphene oxide (rGO) was employed to modify the PAD so that it could function as a solid-contact transducer. A new macrocyclic pyrido-hexapeptide derivative was made and used as a special ionophore in the creatinine membrane sensor. The synthesized PAD showed a detection limit of 1.0 µM (S/N = 3) and a potentiometric response towards creatinine throughout a log-linear range of 2.0 µM-10 mM (R2 = 0.9998). The sensor shows significant selectivity for a few related substances, including ephedrine, codeine, ketamine, caffeine, urea, urate, carbinoxamine, and dextromethorphan. It has been established that the testing method is appropriate for the direct potentiometric detection of creatinine in a variety of human urine sample types. When an indicating electrode and a reference electrode are put on the same flexible disposable, this lets applications with a small sample volume be done. For point-of-care creatinine measurement, the developed paper-based analytical equipment is a good choice because it is affordable, easily accessible, and self-pumping (especially when combined with potentiometric detection).


Asunto(s)
Urinálisis , Humanos , Creatinina , Potenciometría , Electrodos
11.
Anal Chem ; 96(8): 3672-3678, 2024 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-38361229

RESUMEN

Redox potentiometry has emerged as a new platform for in vivo sensing, with improved neuronal compatibility and strong tolerance against sensitivity variation caused by protein fouling. Although enzymes show great possibilities in the fabrication of selective redox potentiometry, the fabrication of an enzyme electrode to output open-circuit voltage (EOC) with fast response remains challenging. Herein, we report a concept of novel enzymatic galvanic redox potentiometry (GRP) with improved time response coupling the merits of the high selectivity of enzyme electrodes with the excellent biocompatibility and reliability of GRP sensors. With a glucose biosensor as an illustration, we use flavin adenine dinucleotide-dependent glucose dehydrogenase as the recognition element and carbon black as the potential relay station to improve the response time. We find that the enzymatic GRP biosensor rapidly responds to glucose with a good linear relationship between EOC and the logarithm of glucose concentration within a range from 100 µM to 2.65 mM. The GRP biosensor shows high selectivity over O2 and coexisting neurochemicals, good reversibility, and sensitivity and can in vivo monitor glucose dynamics in rat brain. We believe that this study will pave a new platform for the in vivo potentiometric biosensing of chemical events with high reliability.


Asunto(s)
Técnicas Biosensibles , Glucosa Oxidasa , Potenciometría , Reproducibilidad de los Resultados , Glucosa Oxidasa/metabolismo , Electrodos , Glucosa , Oxidación-Reducción , Glucosa 1-Deshidrogenasa/metabolismo
12.
Angew Chem Int Ed Engl ; 63(12): e202318973, 2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38272831

RESUMEN

Spreading depolarization (SD) is one of the most common neuropathologic phenomena in the nervous system, relating to numerous diseases. However, real-time monitoring the rapid chemical changes during SD to probe the molecular mechanism remains a great challenge. We develop a potentiometric dual-channel microsensor for simultaneous monitoring of H2 S and pH featuring excellent selectivity and spatiotemporal resolution. Using this microsensor we first observe real time changes of H2 S and pH in the rat brain induced by SD. This changes of H2 S are completely suppressed when the rat pre-treats with aminooxyacetic acid (AOAA), a blocker to inhibit the H2 S-producing enzyme, indicating H2 S fluctuation might be related to enzyme-dependent pathway during SD and less pH-dependent. This study provides a new perspective for studying the function of H2 S and the molecular basis of SD-associated diseases.


Asunto(s)
Encéfalo , Ratas , Animales , Potenciometría , Concentración de Iones de Hidrógeno
13.
Biosens Bioelectron ; 248: 115971, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38154328

RESUMEN

Apomorphine is a dopamine agonist that is used for the management of Parkinson's disease and has been proven to effectively decrease the off-time duration, where the symptoms recur, in Parkinson's disease patients. This paper describes the design and fabrication of the first potentiometric sensor for the determination of apomorphine in bulk and human plasma samples. The fabrication protocol involves stereolithographic 3D printing, which is a unique tool for the rapid fabrication of low-cost sensors. The solid-contact apomorphine ion-selective electrode combines a carbon-mesh/thermoplastic composite as the ion-to-electron transducer and a 3D printed ion-selective membrane, doped with the ionophore calix[6]arene. The sensor selectively measures apomorphine in the presence of other biologically present cations - sodium, potassium, magnesium, and calcium - as well as the commonly prescribed Parkinson's pharmaceutical, levodopa (L-Dopa). The sensor demonstrated a linear, Nernstian response, with a slope of 58.8 mV/decade over the range of 5.0 mM-9.8 µM, which covers the biologically (and pharmaceutically) relevant ranges, with a limit of detection of 2.51 µM. Moreover, the apomorphine sensor exhibited good stability (minimal drift of just 188 µV/hour over 10 h) and a shelf-life of almost 4 weeks. Experiments performed in the presence of albumin, the main plasma protein to which apomorphine binds, demonstrate that the sensor responds selectively to free-apomorphine (i.e., not bound or complexed forms). The utility of the sensor was confirmed through the successful determination of apomorphine in spiked human plasma samples.


Asunto(s)
Técnicas Biosensibles , Enfermedad de Parkinson , Humanos , Apomorfina , Enfermedad de Parkinson/tratamiento farmacológico , Electrodos de Iones Selectos , Preparaciones Farmacéuticas , Potenciometría
14.
Sensors (Basel) ; 23(23)2023 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-38067881

RESUMEN

In the present work, potentiometric sensors with polymer membranes used for chlorhexidine (CHXD) determination were developed. The polymer membranes were plasticized with bis(2-ethylheksyl)sebacate (DOS) or 2-nitrophenyloctyl ether (o-NPOE). The active compounds used in the membrane were cyclodextrins, crown ethers, and ion exchangers. The best-constructed electrode was based on neutral heptakis(2,3,6-tri-O-benzoyl)-ß-cyclodextrin with lipophilic salt (KTpClBP)-potassium tetrakis(4-chlorophenyl) borate-dissolved in plasticizer, DOS. The presented electrode is characterized by an average cationic slope of 30.9 ± 2.9 mV decade-1 within a linear range of 1 × 10-6 to 1 × 10-3 mol × L-1, while the value of the correlation coefficient is 0.9970 ± 0.0026. The response time was about 5 s when increasing the sample concentration and about 10 s when diluting the sample. The electrode potential is independent of the pH within a range of 4.0-9.5. The polymeric membrane sensor was successfully applied for assays of chlorhexidine digluconate in pure samples and pharmaceutical samples. The relative error from three replicate measurements was determined to be 1.1%. and the accuracy was RSD = 0.3-1.1%.


Asunto(s)
Clorhexidina , Membranas Artificiales , Electrodos , Potenciometría , Polímeros , Concentración de Iones de Hidrógeno
15.
Molecules ; 28(22)2023 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-38005274

RESUMEN

Gemcitabine is a chemotherapeutic agent used to treat various malignancies, including breast and bladder cancer. In the current study, three innovative selective gemcitabine hydrochloride sensors are developed using 4-tert-butylcalix-[8]-arene (sensor 1), ß-cyclodextrin (sensor 2), and γ-cyclodextrin (sensor 3) as ionophores. The three sensors were prepared by incorporating the ionophores with o-nitrophenyl octyl ether as plasticizer and potassium tetrakis(4-chlorophenyl) borate as ionic additive into a polyvinyl chloride polymer matrix. These sensors are considered environmentally friendly systems in the analytical research. The linear responses of gemcitabine hydrochloride were in the concentration range of 6.0 × 10-6 to 1.0 × 10-2 mol L-1 and 9.0 × 10-6 to 1.0 × 10-2 mol L-1 and 8.0 × 10-6 to 1.0 × 10-2 mol L-1 for sensors 1, 2, and 3, respectively. Over the pH range of 6-9, fast-Nernst slopes of 52 ± 0.6, 56 ± 0.3, and 55 ± 0.8 mV/decade were found in the same order with correlation regressions of 0.998, 0.999, and 0.998, respectively. The lower limits of detection for the prepared sensors were 2.5 × 10-6, 2.2 × 10-6, and 2.7 × 10-6 mol L-1. The sensors showed high selectivity and sensitivity for gemcitabine. Validation of the sensors was carried out in accordance with the requirements established by the IUPAC, while being inexpensive and easy to use in drug formulation. A statistical analysis of the methods in comparison with the official method showed that there was no significant difference in accuracy or precision between them. It was shown that the new sensors could selectively and accurately find gemcitabine hydrochloride in bulk powder, pharmaceutical formulations, and quality control tests. The ionophore-based sensor shows several advantages over conventional PVC membrane sensor sensors regrading the lower limit of detection, and higher selectivity towards the target ion.


Asunto(s)
Antineoplásicos , Gemcitabina , Composición de Medicamentos , Ionóforos , Polímeros , Potenciometría/métodos , Cloruro de Polivinilo
16.
Sci Rep ; 13(1): 20187, 2023 11 18.
Artículo en Inglés | MEDLINE | ID: mdl-37980444

RESUMEN

Analysis of drugs clinically and their identification in biological samples are of utmost importance in the process of therapeutic drug monitoring, also in pharmacokinetic investigations and tracking of illicit medications. These investigations are carried out using a variety of analytical methods, including potentiometric electrodes. Potentiometric electrodes are a wonderful solution for researchers because they outperform other methods in terms of sustainability, greenness, and cost effectiveness. In the current study, ion-selective potentiometric sensors were assembled for the aim of quantification of the anticancer drug Letrozole (LTZ). The first step was fabrication of a conventional sensor based on the formation of stable host-guest inclusion complex between the cationic drug and 4-tert-butylcalix-8-arene (TBCAX-8). Two additional sensors were prepared through membrane modification with graphene nanocomposite (GNC) and polyaniline (PANI) nanoparticles. Linear responses of 1.00 × 10-5-1.00 × 10-2, 1.00 × 10-6-1.00 × 10-2 and 1.00 × 10-8-1.00 × 10-3 with sub-Nernstian slopes of 19.90, 20.10 and 20.30 mV/decade were obtained for TBCAX-8, GNC, and PANI sensors; respectively. The developed sensors were successful in determining the drug LTZ in bulk powder and dosage form. PANI modified sensor was used to determine LTZ in human plasma with recoveries ranging from 88.00 to 96.30%. IUPAC recommendations were followed during the evaluation of the electrical performance of the developed sensors. Experimental conditions as temperature and pH were studied and optimized. Analytical Eco-scale and Analytical GREEness metric were adopted as the method greenness assessment tools.


Asunto(s)
Grafito , Electrodos de Iones Selectos , Humanos , Letrozol , Electrodos , Potenciometría/métodos
17.
Ceska Slov Farm ; 72(4): 165-171, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37805262

RESUMEN

Based on the data in the Ph. Eur., some other newer pharmacopoeias and published experimental papers propose to revise the text of Ph. Eur. 2.5.8. First, it is necessary to specify which of the electrometric methods should be used to indicate the endpoint of diazotization titrations in Ph. Eur. (preferable potentiometry with a platinum indicating electrode). The amount of potassium bromide in the titration solution may be reduced to 1 g, the cooling of the solution before titration may be omitted from the framework procedure, and it may be specified in individual monographs if necessary to obtain accurate and correct results for some medicines. Diazotization titration can be performed in Ph. Eur. and can also be used to determine the content of some other medicines.


Asunto(s)
Potenciometría , Control de Calidad , Europa (Continente) , Potenciometría/métodos
18.
Biosens Bioelectron ; 241: 115701, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-37757510

RESUMEN

We present a portable multiplexed biosensor platform based on the extended gate field-effect transistor and demonstrate its amplified response thanks to gold nanoparticle-based bioconjugates introduced as a part of the immunoassay. The platform comprises a disposable chip hosting an array of 32 extended gate electrodes, a readout module based on a single transistor operating in constant charge mode, and a multiplexer to scan sensing electrodes one-by-one. Although employing only off-the-shelf electronic components, our platform achieves sensitivities comparable to fully customized nanofabricated potentiometric sensors. In particular, it reaches a detection limit of 0.2 fM for the pure molecular assay when sensing horseradish peroxidase-linked secondary antibody (∼0.4 nM reached by standard microplate methods). Furthermore, with the gold nanoparticle bioconjugation format, we demonstrate ca. 5-fold amplification of the potentiometric response compared to a pure molecular assay, at the detection limit of 13.3 fM. Finally, we elaborate on the mechanism of this amplification and propose that nanoparticle-mediated disruption of the diffusion barrier layer is the main contributor to the potentiometric signal enhancement. These results show the great potential of our portable, sensitive, and cost-efficient biosensor for multidimensional diagnostics in the clinical and laboratory settings, including e.g., serological tests or pathogen screening.


Asunto(s)
Técnicas Biosensibles , Nanopartículas del Metal , Oro , Técnicas Biosensibles/métodos , Potenciometría , Inmunoensayo , Electrodos
19.
Sensors (Basel) ; 23(18)2023 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-37765901

RESUMEN

For the first time, a prototype of a portable device for the potentiometric determination of antioxidant capacity based on a new measurement principle is proposed. A feature of the approach is the use of an electrochemical microcell with separated spaces and two identical electrodes with immobilized reagents. An antioxidant solution is introduced into one half-cell, and the antioxidants interact with the reagents. The other half-cell contains only reagents. The potential difference between the electrodes is due to the change in the ratio of the oxidized and reduced form of the reagents, which occurs as a result of the reaction with the antioxidants in one of the half-cells and is related to their concentration. The range of linearity of the microcell with immobilized reagents is 40-4000 µM-eq, and the limit of detection is 20 µM-eq. The device was successfully tested in the analysis of standard antioxidant solutions. The recoveries were (92-113)%, and the relative standard deviation did not exceed 15%. A good correlation was found between the data obtained by the approach and the potentiometric method in a macrocell for fruit juice analysis. Pearson's coefficient for the obtained experimental data was 0.9955. The proposed portable device is promising and can be used in field conditions.


Asunto(s)
Antioxidantes , Potenciometría/métodos , Electrodos
20.
ACS Sens ; 8(11): 4198-4206, 2023 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-37773015

RESUMEN

The high-temperature potentiometry operated by nonisothermal heating is a promising way to break through the traditional potentiometric responses of ion-selective electrodes (ISEs) at room temperature. Herein, a locally heated strategy through near-infrared region (NIR) laser irradiation upon the photothermal mesoporous carbon material placed between the ion-selective membrane and the glassy carbon substrate is introduced to obtain the high-temperature potentiometric performance of a solid-contact Ca2+-ISE for detection of Ca2+ in seawater. Based on the light-to-heat conversion of the mesoporous carbon-based solid contact, the temperature of the solid-contact Ca2+-ISE upon continuous NIR laser irradiation can be increased from room temperature to 60-70 °C, and the slope of the electrode is promoted up to about 30% according to the thermodynamic steady-state potentiometric response. The pulsed potentiometric response of the solid-contact Ca2+-ISE upon a pulsed NIR laser irradiation of 5 s also shows a linear change as a function of Ca2+ activities, and the improved slope from 27.1 ± 0.6 to 38.1 ± 0.9 mV/dec can be obtained under dual control of the temperature of the electrode and the transient current induced by the pulsed NIR laser irradiation. As compared to the traditional potentiometric measurement under zero-current conditions at room temperature, the NIR laser-modulated high-temperature potentiometric response provides an alternative way for measurement of the solid-contact ISEs.


Asunto(s)
Carbono , Electrodos de Iones Selectos , Potenciometría , Temperatura , Agua de Mar , Rayos Infrarrojos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...