Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 17.320
Filtrar
1.
Crit Care ; 28(1): 187, 2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38816883

RESUMEN

BACKGROUND: Although several trials were conducted to optimize the oxygenation range in intensive care unit (ICU) patients, no studies have yet reached a universal recommendation on the optimal a partial pressure of oxygen in arterial blood (PaO2) range in patients with sepsis. Our aim was to evaluate whether a relatively high arterial oxygen tension is associated with longer survival in sepsis patients compared with conservative arterial oxygen tension. METHODS: From the Korean Sepsis Alliance nationwide registry, patients treated with liberal PaO2 (PaO2 ≥ 80 mm Hg) were 1:1 matched with those treated with conservative PaO2 (PaO2 < 80 mm Hg) over the first three days after ICU admission according to the propensity score. The primary outcome was 28-day mortality. RESULTS: The median values of PaO2 over the first three ICU days in 1211 liberal and 1211 conservative PaO2 groups were, respectively, 107.2 (92.0-134.0) and 84.4 (71.2-112.0) in day 1110.0 (93.4-132.0) and 80.0 (71.0-100.0) in day 2, and 106.0 (91.9-127.4) and 78.0 (69.0-94.5) in day 3 (all p-values < 0.001). The liberal PaO2 group showed a lower likelihood of death at day 28 (14.9%; hazard ratio [HR], 0.79; 95% confidence interval [CI] 0.65-0.96; p-value = 0.017). ICU (HR, 0.80; 95% CI 0.67-0.96; p-value = 0.019) and hospital mortalities (HR, 0.84; 95% CI 0.73-0.97; p-value = 0.020) were lower in the liberal PaO2 group. On ICU days 2 (p-value = 0.007) and 3 (p-value < 0.001), but not ICU day 1, hyperoxia was associated with better prognosis compared with conservative oxygenation., with the lowest 28-day mortality, especially at PaO2 of around 100 mm Hg. CONCLUSIONS: In critically ill patients with sepsis, higher PaO2 (≥ 80 mm Hg) during the first three ICU days was associated with a lower 28-day mortality compared with conservative PaO2.


Asunto(s)
Enfermedad Crítica , Unidades de Cuidados Intensivos , Oxígeno , Sepsis , Humanos , Masculino , Femenino , Persona de Mediana Edad , Enfermedad Crítica/mortalidad , Enfermedad Crítica/terapia , Anciano , Sepsis/mortalidad , Sepsis/sangre , Sepsis/terapia , República de Corea/epidemiología , Estudios de Cohortes , Oxígeno/sangre , Unidades de Cuidados Intensivos/organización & administración , Unidades de Cuidados Intensivos/estadística & datos numéricos , Presión Parcial , Sistema de Registros/estadística & datos numéricos , Mortalidad Hospitalaria , Análisis de los Gases de la Sangre/métodos , Análisis de los Gases de la Sangre/estadística & datos numéricos
2.
Neurosurg Rev ; 47(1): 222, 2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38758384

RESUMEN

To assess whether monitoring brain tissue oxygen partial pressure (PbtO2) or employing intracranial pressure (ICP)/cerebral perfusion pressure (CCP)-guided management improves patient outcomes, including mortality, hospital length of stay (LOS), mean daily ICP and mean daily CCP during the intensive care unit(ICU)stay. We searched the Web of Science, EMBASE, PubMed, Cochrane Library, and MEDLINE databases until December 12, 2023. Prospective randomized controlled and cohort studies were included. A meta-analysis was performed for the primary outcome measure, mortality, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Eleven studies with a total of 37,492 patients were included. The mortality in the group with PbtO2 was 29.0% (odds ratio: 0.73;95% confidence interval [CI]:0.56-0.96; P = 0.03; I = 55%), demonstrating a significant benefit. The overall hospital LOS was longer in the PbtO2 group than that in the ICP/CPP group (mean difference:2.03; 95% CI:1.03-3.02; P<0.0001; I = 39%). The mean daily ICP in the PbtO2 monitoring group was lower than that in the ICP/CPP group (mean difference:-1.93; 95% CI: -3.61 to -0.24; P = 0.03; I = 41%). Moreover, PbtO2 monitoring did not improve the mean daily CPP (mean difference:2.43; 95%CI: -1.39 to 6.25;P = 0.21; I = 56%).Compared with ICP/CPP monitoring, PbtO2 monitoring reduced the mortality and the mean daily ICP in patients with severe traumatic brain injury; however, no significant effect was noted on the mean daily CPP. In contrast, ICP/CPP monitoring alone was associated with a short hospital stay.


Asunto(s)
Lesiones Traumáticas del Encéfalo , Encéfalo , Presión Intracraneal , Oxígeno , Humanos , Lesiones Traumáticas del Encéfalo/mortalidad , Lesiones Traumáticas del Encéfalo/diagnóstico , Lesiones Traumáticas del Encéfalo/terapia , Circulación Cerebrovascular/fisiología , Presión Intracraneal/fisiología , Tiempo de Internación , Monitoreo Fisiológico/métodos , Oxígeno/metabolismo , Oxígeno/sangre , Presión Parcial , Pronóstico
4.
Shock ; 61(6): 836-840, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38713552

RESUMEN

ABSTRACT: Objective: This study aimed to investigate the effect of the central venous-to-arterial carbon dioxide partial pressure difference (Pcv-aCO2) on the administration of cardiotonic drugs in patients with early-stage septic shock. Methods: A retrospective study was conducted on 120 patients suffering from septic shock. At admission, the left ventricular ejection fraction (LVEF) and Pcv-aCO2 of the patients were obtained. On the premise of mean arterial pressure ≥ 65 mm Hg, the patients were divided into two groups according to the treatment approaches adopted by different doctors-control group: LVEF ≤50% and observation group: Pcv-aCO2 ≥ 6. Both groups received cardiotonic therapy. Results: The two groups of patients had similar general conditions and preresuscitation conditions ( P > 0.05). Compared with the control group, the observation group had a higher mean arterial pressure, lactic acid clearance rate, and urine output after 6 h of resuscitation ( P < 0.05), but a lower absolute value of lactic acid, total fluid intake in 24 h, and a lower number of patients receiving renal replacement therapy during hospitalization ( P < 0.05). After 6 hours of resuscitation, the percentages of patients meeting central venous oxygen saturation and central venous pressure targets were not significantly different between the control and observation groups ( P > 0.05). There was no difference in the 28-day mortality rate between the two groups ( P > 0.05). Conclusion: Pcv-aCO2 is more effective than LVEF in guiding the administration of cardiotonic drugs in the treatment of patients with septic shock.


Asunto(s)
Dióxido de Carbono , Cardiotónicos , Presión Venosa Central , Choque Séptico , Humanos , Choque Séptico/tratamiento farmacológico , Choque Séptico/terapia , Masculino , Femenino , Estudios Retrospectivos , Dióxido de Carbono/sangre , Anciano , Persona de Mediana Edad , Cardiotónicos/uso terapéutico , Presión Parcial
6.
Zhonghua Yi Xue Za Zhi ; 104(15): 1221-1224, 2024 Apr 16.
Artículo en Chino | MEDLINE | ID: mdl-38637159

RESUMEN

Acute Respiratory Distress Syndrome (ARDS) is distinguished by hypoxemia, contributing to heightened morbidity, elevated mortality rates, and substantial healthcare expenses, thereby imposing a significant burden on patients and society. Presently, effective treatments for ARDS are lacking, emphasizing the pivotal role of early diagnosis and timely intervention in its successful management. The partial pressure of oxygen/fraction of inspired oxygen (PaO2/FiO2, P/F) has traditionally served as a crucial metric for assessing patient hypoxemia and disease severity. While relatively accurate, its reliance on advanced technical expertise and specific medical equipment conditions constrains its implementation in areas with underdeveloped medical standards, resulting in missed diagnoses and treatments for ARDS patients. Conversely, the Pulse oximetric saturation/fraction of inspired oxygen (SpO2/FiO2, S/F) has garnered increasing attention owing to its straightforward, non-invasive, and sustainable monitoring attributes. This article seeks to meticulously compare the correlation, accuracy, and clinical feasibility of S/F with P/F in ARDS diagnosis, so as to propose diagnostic indicators for more quickly and accurately assessing the oxygenation status of ARDS patients.


Asunto(s)
Oxígeno , Síndrome de Dificultad Respiratoria , Humanos , Presión Parcial , Oximetría/métodos , Síndrome de Dificultad Respiratoria/diagnóstico , Síndrome de Dificultad Respiratoria/terapia , Hipoxia
7.
Science ; 383(6690): 1471-1478, 2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38547288

RESUMEN

Consciousness is lost within seconds upon cessation of cerebral blood flow. The brain cannot store oxygen, and interruption of oxidative phosphorylation is fatal within minutes. Yet only rudimentary knowledge exists regarding cortical partial oxygen tension (Po2) dynamics under physiological conditions. Here we introduce Green enhanced Nano-lantern (GeNL), a genetically encoded bioluminescent oxygen indicator for Po2 imaging. In awake behaving mice, we uncover the existence of spontaneous, spatially defined "hypoxic pockets" and demonstrate their linkage to the abrogation of local capillary flow. Exercise reduced the burden of hypoxic pockets by 52% compared with rest. The study provides insight into cortical oxygen dynamics in awake behaving animals and concurrently establishes a tool to delineate the importance of oxygen tension in physiological processes and neurological diseases.


Asunto(s)
Corteza Cerebral , Circulación Cerebrovascular , Hipoxia Encefálica , Mediciones Luminiscentes , Saturación de Oxígeno , Oxígeno , Animales , Ratones , Corteza Cerebral/irrigación sanguínea , Corteza Cerebral/diagnóstico por imagen , Corteza Cerebral/metabolismo , Oxígeno/sangre , Oxígeno/metabolismo , Presión Parcial , Hipoxia Encefálica/sangre , Hipoxia Encefálica/diagnóstico por imagen , Hipoxia Encefálica/metabolismo , Vasodilatación , Mediciones Luminiscentes/métodos , Luciferasas/genética , Luciferasas/metabolismo , Proteínas Recombinantes de Fusión/genética , Proteínas Recombinantes de Fusión/metabolismo , Proteínas Fluorescentes Verdes/genética , Proteínas Fluorescentes Verdes/metabolismo , Hipercapnia/sangre , Hipercapnia/diagnóstico por imagen , Hipercapnia/metabolismo
8.
Opt Lett ; 49(5): 1369-1372, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38427015

RESUMEN

Pump-probe-based photoacoustic tomography (PP-PAT) is an innovative and promising molecular imaging technique. In this study, we utilized PP-PAT for the first time, to the best of our knowledge, to monitor the dynamics of oxygen partial pressure (pO2) within murine tumors during photodynamic therapy (PDT) with methylene blue (MB). We developed, to our knowledge, a novel two-step fitting method to simultaneously map both the pO2 and the MB concentrations and implemented it with mexCuda to accelerate the pixel-wise-based calculation. The results demonstrated a penetration depth of up to 5 mm and revealed a significant decrease in pO2 during the PDT process, consistent with existing research findings. This study suggests that PP-PAT has the potential to become a valuable tool for intraoperative monitoring of PDT, thereby enhancing therapeutic efficacy.


Asunto(s)
Neoplasias , Fotoquimioterapia , Humanos , Ratones , Animales , Fotoquimioterapia/métodos , Presión Parcial , Tomografía Computarizada por Rayos X , Oxígeno , Azul de Metileno , Fármacos Fotosensibilizantes
9.
Am J Emerg Med ; 79: 105-110, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38417220

RESUMEN

OBJECTIVES: There is currently conflicting data as to the effects of hypercapnia on clinical outcomes among mechanically ventilated patients in the emergency department (ED). These conflicting results may be explained by the degree of acidosis. We sought to test the hypothesis that hypercapnia is associated with increased in-hospital mortality and decreased ventilator-free days at lower pH, but associated with decreased in-hospital mortality and increased ventilator-free days at higher pH, among patients requiring mechanical ventilation in the emergency department (ED). METHODS: Secondary analysis of patient level data from prior clinical trials and cohort studies that enrolled adult patients who required mechanical ventilation in the ED. Patients who had a documented blood gas while on mechanical ventilation in the ED were included in these analyses. The primary outcome was in-hospital mortality, and secondary outcome was ventilator-free days. Mixed-effects logistic, linear, and survival-time regression models were used to test if pH modified the association between partial pressure of carbon dioxide (pCO2) and outcome measures. RESULTS: Of the 2348 subjects included, the median [interquartile range (IQR)] pCO2 was 43 (35-54) and pH was 7.31 (7.22-7.39). Overall, in-hospital mortality was 27%. We found pH modified the association between pCO2 and outcomes, with higher pCO2 associated with increased probability of in-hospital mortality when pH is below 7.00, and decreased probability of in-hospital mortality when pH is above 7.10. These results remained consistent across multiple sensitivity and subgroup analyses. A similar relationship was found with ventilator-free days. CONCLUSIONS: Higher pCO2 is associated with decreased mortality and greater ventilator-free days when pH is >7.10; however, it is associated with increased mortality and fewer ventilator-free days when the pH is below 7.00. Targeting pCO2 based on pH in the ED may be a potential intervention target for future clinical trials to improve clinical outcomes.


Asunto(s)
Dióxido de Carbono , Respiración Artificial , Adulto , Humanos , Respiración Artificial/métodos , Hipercapnia/etiología , Presión Parcial , Servicio de Urgencia en Hospital , Concentración de Iones de Hidrógeno
10.
BMC Pediatr ; 24(1): 149, 2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38424493

RESUMEN

BACKGROUND: Measuring arterial partial pressure of carbon dioxide (PaCO2) is crucial for proper mechanical ventilation, but the current sampling method is invasive. End-tidal carbon dioxide (EtCO2) has been used as a surrogate, which can be measured non-invasively, but its limited accuracy is due to ventilation-perfusion mismatch. This study aimed to develop a non-invasive PaCO2 estimation model using machine learning. METHODS: This retrospective observational study included pediatric patients (< 18 years) admitted to the pediatric intensive care unit of a tertiary children's hospital and received mechanical ventilation between January 2021 and June 2022. Clinical information, including mechanical ventilation parameters and laboratory test results, was used for machine learning. Linear regression, multilayer perceptron, and extreme gradient boosting were implemented. The dataset was divided into 7:3 ratios for training and testing. Model performance was assessed using the R2 value. RESULTS: We analyzed total 2,427 measurements from 32 patients. The median (interquartile range) age was 16 (12-19.5) months, and 74.1% were female. The PaCO2 and EtCO2 were 63 (50-83) mmHg and 43 (35-54) mmHg, respectively. A significant discrepancy of 19 (12-31) mmHg existed between EtCO2 and the measured PaCO2. The R2 coefficient of determination for the developed models was 0.799 for the linear regression model, 0.851 for the multilayer perceptron model, and 0.877 for the extreme gradient boosting model. The correlations with PaCO2 were higher in all three models compared to EtCO2. CONCLUSIONS: We developed machine learning models to non-invasively estimate PaCO2 in pediatric patients receiving mechanical ventilation, demonstrating acceptable performance. Further research is needed to improve reliability and external validation.


Asunto(s)
Dióxido de Carbono , Respiración Artificial , Femenino , Humanos , Lactante , Masculino , Capnografía/métodos , Presión Parcial , Reproducibilidad de los Resultados
11.
Intensive Care Med ; 50(2): 258-267, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38353714

RESUMEN

PURPOSE: This study aimed to determine the best strategy to achieve fast and safe extubation. METHODS: This multicenter trial randomized patients with primary respiratory failure and low-to-intermediate risk for extubation failure with planned high-flow nasal cannula (HFNC) preventive therapy. It included four groups: (1) conservative screening with ratio of partial pressure of arterial oxygen (PaO2) to fraction of inspired oxygen (FiO2) ≥ 150 and positive end-expiratory pressure (PEEP) ≤ 8 cmH2O plus conservative spontaneous breathing trial (SBT) with pressure support 5 cmH2O + PEEP 0 cmH2O); (2) screening with ratio of partial pressure of arterial oxygen (PaO2) to fraction of inspired oxygen (FiO2) ≥ 150 and PEEP ≤ 8 plus aggressive SBT with pressure support 8 + PEEP 5; (3) aggressive screening with PaO2/FiO2 > 180 and PEEP 10 maintained until the SBT with pressure support 8 + PEEP 5; (4) screening with PaO2/FiO2 > 180 and PEEP 10 maintained until the SBT with pressure support 5 + PEEP 0. Primary outcomes were time-to-extubation and simple weaning rate. Secondary outcomes included reintubation within 7 days after extubation. RESULTS: Randomization to the aggressive-aggressive group was discontinued at the interim analysis for safety reasons. Thus, 884 patients who underwent at least 1 SBT were analyzed (conservative-conservative group, n = 256; conservative-aggressive group, n = 267; aggressive-conservative group, n = 261; aggressive-aggressive, n = 100). Median time to extubation was lower in the groups with aggressive screening (p < 0.001). Simple weaning rates were 45.7%, 76.78% (205 patients), 71.65%, and 91% (p < 0.001), respectively. Reintubation rates did not differ significantly (p = 0.431). CONCLUSION: Among patients at low or intermediate risk for extubation failure with planned HFNC, combining aggressive screening with preventive PEEP and a conservative SBT reduced the time to extubation without increasing the reintubation rate.


Asunto(s)
Extubación Traqueal , Arterias , Humanos , Presión Parcial , Presión , Oxígeno
12.
Asian J Surg ; 47(5): 2152-2160, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38238140

RESUMEN

PURPOSE: Change in venous-to-arterial carbon dioxide partial pressure difference[P(v-a)CO2] could be a useful marker to assess tissue perfusion status. Herein, we assessed the predictive values of postoperative P(v-a)CO2 measurements for mortality in critically ill patients after major surgery. The correlation between P(v-a)CO2 values and other conventional parameters of patient prognosis was also evaluated. METHODS: Patients admitted to the intensive care unit(ICU) after abdominal surgery were enrolled. Arterial and venous blood gas analyses were performed within 1 h(T0) and after 24 h(T1) of admission to the ICU, respectively. The relationship between P(v-a)CO2 levels at T1 and other conventional parameters were assessed using a Bland-Altman plot. Logistic regression analysis was performed to examine the predisposing factors of mortality after surgery. RESULTS: A total of 231 patients were finally analyzed. We divided the participants into the high PvaCO2 group[P(v-a)CO2 ≥ 8.6] and the low PvaCO2 group[P(v-a)CO2 < 8.6]. Seven-day-, 28-day, and in-hospital mortality were significantly higher in the high PvaCO2 group than in the low PvaCO2 group. There was significant agreement between P(v-a)CO2 values at T1 and APACHE II scores, lactate levels at T1 and total SOFA scores at T1. In multivariate logistic analysis, an increased P(v-a)CO2 value at T1 was the only significant risk factor of 7-day mortality after surgery. [odds ratio:1.341, 95%confidence interval: 1.050-1.714, p=0.019]. CONCLUSION: P(v-a)CO2 measurements could be not only a significant predictor of postoperative prognosis, but also a useful surveillance parameter to maintain tissue perfusion after abdominal surgery in patients with a potential risk of fatal complication-related tissue hypoperfusion.


Asunto(s)
Análisis de los Gases de la Sangre , Dióxido de Carbono , Valor Predictivo de las Pruebas , Humanos , Femenino , Masculino , Dióxido de Carbono/sangre , Persona de Mediana Edad , Pronóstico , Anciano , Arterias , Mortalidad Hospitalaria , Abdomen/cirugía , Enfermedad Crítica , Venas , Unidades de Cuidados Intensivos , Presión Parcial , Biomarcadores/sangre
13.
BMC Anesthesiol ; 24(1): 23, 2024 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-38216876

RESUMEN

BACKGROUND: Patients with COVID-19 undergoing pressure support ventilation (PSV) with extracorporeal membrane oxygenation (ECMO) commonly had high respiratory drive, which could cause self-inflicted lung injury. The aim of this study was to evaluate the influence of different levels of partial pressure of carbon dioxide(PaCO2) on respiratory effort in COVID-19 patients undergoing PSV with ECMO. METHODS: ECMO gas flow was downregulated from baseline (respiratory rate < 25 bpm, peak airway pressure < 25 cm H2O, tidal volume < 6 mL/kg, PaCO2 < 40 mmHg) until PaCO2 increased by 5 - 10 mmHg. The pressure muscle index (PMI) and airway pressure swing during occlusion (ΔPOCC) were used to monitor respiratory effort, and they were measured before and after enforcement of the regulations. RESULTS: Ten patients with COVID-19 who had undergone ECMO were enrolled in this prospective study. When the PaCO2 increased from 36 (36 - 37) to 42 (41-43) mmHg (p = 0.0020), there was a significant increase in ΔPOCC [from 5.6 (4.7-8.0) to 11.1 (8.5-13.1) cm H2O, p = 0.0020] and PMI [from 3.0 ± 1.4 to 6.5 ± 2.1 cm H2O, p < 0.0001]. Meanwhile, increased inspiratory effort determined by elevated PaCO2 levels led to enhancement of tidal volume from 4.1 ± 1.2 mL/kg to 5.3 ± 1.5 mL/kg (p = 0.0003) and respiratory rate from 13 ± 2 to 15 ± 2 bpm (p = 0.0266). In addition, the increase in PaCO2 was linearly correlated with changes in ΔPOCC and PMI (R2 = 0.7293, p = 0.0003 and R2 = 0.4105, p = 0.0460, respectively). CONCLUSIONS: In patients with COVID-19 undergoing PSV with ECMO, an increase of PaCO2 could increase the inspiratory effort.


Asunto(s)
COVID-19 , Oxigenación por Membrana Extracorpórea , Humanos , Presión Parcial , Dióxido de Carbono , Estudios Prospectivos , COVID-19/terapia , Respiración Artificial
14.
Vet Anaesth Analg ; 51(1): 10-15, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37949743

RESUMEN

OBJECTIVE: To evaluate the relationship between oxygen reserve index (ORI) and arterial partial pressure of oxygen (PaO2) in anesthetized dogs. STUDY DESIGN: Prospective experimental study. ANIMALS: A total of eight healthy adult Beagle dogs with a median age of 38 (range 20-87) months and a median body mass of 8.6 (range 7.0-13.8) kg. METHODS: After induction of general anesthesia with propofol, dogs were mechanically ventilated and anesthesia maintained with isoflurane carried in oxygen. Arterial blood samples were collected from a catheter placed in the femoral artery. ORI was measured by placing a CO-oximeter sensor on the tongue. Inspired oxygen fraction (FiO2) was increased from 21% to > 95% in increments of 5%. PaO2 and ORI were recorded and compared at different times. The relationship between ORI and PaO2 was investigated using a nonlinear function, the Hill equation, and a linear regression analysis was performed, as appropriate. RESULTS: A total of 128 pairs of values were compared for all dogs. Applying the Hill equation to the relationship between ORI and PaO2 resulted in R2 = 0.80 (p < 0.001) with a Hill coefficient of 3.7. It was predicted that ORI ranged 0.1-0.9 as PaO2 ranged 127.0-417.9 mmHg and that in the more linear portion of the range, PaO2 of 127.0-289.9 mmHg ORI ranged 0.1-0.7. Linear regression analysis in the more linear portion showed a weak correlation (R2 = 0.29, p = 0.006). CONCLUSIONS AND CLINICAL RELEVANCE: In the present study, the Hill equation predicted the relationship between PaO2 and ORI for PaO2 ranging 127.0-417.9 mmHg in anesthetized dogs. However, in the linear portion of the PaO2, the coefficient of determination was low, indicating that ORI is not a surrogate for PaO2.


Asunto(s)
Oximetría , Oxígeno , Perros , Animales , Estudios Prospectivos , Presión Parcial , Oximetría/veterinaria , Anestesia General/veterinaria , Análisis de los Gases de la Sangre/veterinaria
15.
Surg Today ; 54(2): 122-129, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37278878

RESUMEN

PURPOSE: To establish accurate diagnostic criteria and predictors of treatment response for postoperative acute exacerbation (AE) in patients with lung cancer and idiopathic interstitial pneumonia (IIP). METHODS: Among 93 patients with IIP who underwent surgery for lung cancer, suspected postoperative AE developed in 20 (21.5%). Patients were divided into a progressive AE group, comprising patients with bilateral alveolar opacities and decreasing PaO2 ≥ 10 mmHg (n = 5); an incipient AE group, comprising patients with unilateral alveolar opacities and decreasing PaO2 ≥ 10 mmHg (n = 10); and an indeterminate AE group, comprising patients with alveolar opacities but decreasing PaO2 < 10 mmHg (n = 5). RESULTS: The progressive AE group had significantly higher 90-day mortality (80%) than the incipient AE group (10%, P = 0.017) or the indeterminate AE group (0%, P = 0.048). Bilateral opacities may indicate advanced AE and poor prognosis, whereas unilateral opacities may indicate an early stage of AE and a good prognosis. PaO2 < 10 mmHg may indicate conditions other than AE. CONCLUSIONS: In patients with lung cancer and IIP, decreasing PaO2 and HRCT findings may allow for the initiation of rapid and accurate treatment strategies for postoperative AE.


Asunto(s)
Neumonías Intersticiales Idiopáticas , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/complicaciones , Neoplasias Pulmonares/cirugía , Oxígeno , Presión Parcial , Estudios Retrospectivos , Neumonías Intersticiales Idiopáticas/diagnóstico por imagen , Pronóstico , Progresión de la Enfermedad
16.
Respir Care ; 69(3): 339-344, 2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-37253608

RESUMEN

BACKGROUND: Infants with hypoxic-ischemic encephalopathy are often treated with therapeutic hypothermia and high-frequency ventilation. Fluctuations in PaCO2 during therapeutic hypothermia are associated with poor neurodevelopmental outcomes. Transcutaneous CO2 monitors offer a noninvasive estimate of PaCO2 represented by transcutaneously measured partial pressure of carbon dioxide (PtcCO2 ). We aimed to assess the precision between PtcCO2 and PaCO2 values in neonates undergoing therapeutic hypothermia. METHODS: This was a retrospective chart review of 10 neonates who underwent therapeutic hypothermia requiring respiratory support over 2 y. A range of 2-27 simultaneous PtcCO2 and PaCO2 pairs of measurements per neonate were analyzed via linear mixed models and a Bland-Altman plot for multiple observations per neonate. RESULTS: A linear mixed-effect model demonstrated that PtcCO2 and PaCO2 (controlling for sex) were similar. The 95% CI of the mean difference ranged from -2.3 to 5.7 mm Hg (P = .41). However, precision was poor as the PtcCO2 ranged from > 18 mm Hg to < 13 mm Hg than PaCO2 values for 95% of observations. CONCLUSIONS: The neonates' PtcCO2 was as much as 18 mm Hg higher to 13 mm Hg lower than the PaCO2 95% of the time. Transcutaneous CO2 monitoring may not be a good trending tool, nor is it appropriate for estimating PaCO2 in patients undergoing therapeutic hypothermia.


Asunto(s)
Dióxido de Carbono , Hipotermia Inducida , Recién Nacido , Humanos , Monitoreo de Gas Sanguíneo Transcutáneo , Estudios Retrospectivos , Presión Parcial
17.
Anesth Analg ; 138(3): 607-615, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-37319022

RESUMEN

BACKGROUND: Changes in arterial partial pressure of carbon dioxide (Pa co2 ) may alter cerebral perfusion in critically ill patients with acute brain injury. Consequently, international guidelines recommend normocapnia in mechanically ventilated patients with acute brain injury. The measurement of end-tidal capnography (Et co2 ) allows its approximation. Our objective was to report the agreement between trends in Et co2 and Pa co2 during mechanical ventilation in patients with acute brain injury. METHODS: Retrospective monocenter study was conducted for 2 years. Critically ill patients with acute brain injury who required mechanical ventilation with continuous Et co2 monitoring and with 2 or more arterial gas were included. The agreement was evaluated according to the Bland and Altman analysis for repeated measurements with calculation of bias, and upper and lower limits of agreement. The directional concordance rate of changes between Et co2 and Pa co2 was evaluated with a 4-quadrant plot. A polar plot analysis was performed using the Critchley methods. RESULTS: We analyzed the data of 255 patients with a total of 3923 paired ΔEt co2 and ΔPa co2 (9 values per patient in median). Mean bias by Bland and Altman analysis was -8.1 (95 CI, -7.9 to -8.3) mm Hg. The directional concordance rate between Et co2 and Pa co2 was 55.8%. The mean radial bias by polar plot analysis was -4.4° (95% CI, -5.5 to -3.3) with radial limit of agreement (LOA) of ±62.8° with radial LOA 95% CI of ±1.9°. CONCLUSIONS: Our results question the performance of trending ability of Et co2 to track changes in Pa co2 in a population of critically ill patients with acute brain injury. Changes in Et co2 largely failed to follow changes in Pa co2 in both direction (ie, low concordance rate) and magnitude (ie, large radial LOA). These results need to be confirmed in prospective studies to minimize the risk of bias.


Asunto(s)
Lesiones Encefálicas , Dióxido de Carbono , Humanos , Capnografía/métodos , Estudios Retrospectivos , Respiración Artificial , Estudios Prospectivos , Presión Parcial , Enfermedad Crítica , Lesiones Encefálicas/diagnóstico , Lesiones Encefálicas/terapia
19.
Asian J Surg ; 47(1): 380-388, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37726182

RESUMEN

OBJECTIVE: Patients undergoing lung transplantation (LTx) often experience abnormal hypercapnia or hypocapnia. This study aimed to investigate the association between intraoperative PaCO2 and postoperative adverse outcomes in patients undergoing LTx. METHODS: We retrospectively reviewed the medical records of 151 patients undergoing LTx. Patients' demographics, perioperative clinical factors, and pre- and intraoperative PaCO2 data after reperfusion were collected and analyzed. Based on the PaCO2 levels, patients were classified into three groups: hypocapnia (≤35 mmHg), normocapnia (35.1-55 mmHg), and hypercapnia (>55 mmHg). Univariate and multivariable logistic regressions were used to identify independent risk factors for postoperative composite adverse events and in-hospital mortality. RESULTS: Intraoperative hypercapnia occurred in 69 (45.7%) patients, and hypocapnia in 17 (11.2%). Patients with intraoperative PaCO2 of 35.1-45 mmHg showed a lower incidence of composite adverse events (53.3%) and mortality (6.2%) (P < 0.001). There was no significant difference in composite adverse events and mortality among preoperative PaCO2 groups (P > 0.05). Compared with intraoperative PaCO2 at 35.1-45 mmHg, the risk of composite adverse events in hypercapnia group increased: the adjusted OR was 3.07 (95% confidence interval [CI]: 1.36-6.94; P = 0.007). The risk of death was significantly higher in hypocapnia group than normocapnia group, the adjusted OR was 7.69 (95% CI: 1.68-35.24; P = 0.009). Over ascending ranges of PaCO2, PaCO2 at 55.1-65 mmHg had the strongest association with composite adverse events, the adjusted OR was 6.40 (95% CI: 1.18-34.65; P = 0.031). CONCLUSION: These results demonstrate that intraoperative hypercapnia independently predicts postoperative adverse outcomes in patients undergoing LTx. Intraoperative hypocapnia shows predictive value for postoperative in-hospital mortality in LTx.


Asunto(s)
Dióxido de Carbono , Trasplante de Pulmón , Humanos , Hipercapnia/etiología , Hipocapnia/etiología , Estudios Retrospectivos , Presión Parcial
20.
IEEE Trans Biomed Eng ; 71(3): 929-943, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37812542

RESUMEN

Wearable smart health applications aim to continuously monitor critical physiological parameters without disrupting patients' daily activities, such as giving a blood sample for lab analysis. For example, the partial pressure of arterial carbon dioxide, the critical indicator of ventilation efficacy reflecting the respiratory and acid-base status of the human body, is measured invasively from the arteries. Therefore, it can momentarily be monitored in a clinical setting when the arterial blood sample is taken. Although a noninvasive surrogate method for estimating the partial pressure of arterial carbon dioxide exists (i.e., transcutaneous carbon dioxide monitoring), it is primarily limited to intensive care units and comes in the form of a large bedside device. Nevertheless, recent advancements in the luminescence sensing field have enabled a promising technology that can be incorporated into a wearable device for the continuous and remote monitoring of ventilation efficacy. In this review, we examine existing and nascent techniques for sensing transcutaneous carbon dioxide and highlight novel wearable transcutaneous carbon dioxide monitors by comparing their performance with the traditional bedside counterparts. We also discuss future directions of transcutaneous carbon dioxide monitoring in next-generation smart health applications.


Asunto(s)
Monitoreo de Gas Sanguíneo Transcutáneo , Dióxido de Carbono , Humanos , Monitoreo de Gas Sanguíneo Transcutáneo/métodos , Respiración , Monitoreo Fisiológico/métodos , Presión Parcial
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...