Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.967
Filtrar
1.
Vestn Oftalmol ; 140(2): 72-77, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38742501

RESUMEN

The modern treatment strategy for keratoconus (KC) involves sequential application of medical technologies aimed at stabilizing pathological changes in the cornea and restoring visual acuity. PURPOSE: This study compares the effect of implantation of intrastromal corneal ring segment (ICRS) and fitting of individual scleral rigid contact lenses (RCLs) on visual functions in patients with stage II-III KC after previously performed corneal collagen cross-linking. MATERIAL AND METHODS: The Helmholtz National Medical Research Center of Eye Diseases examined and treated 34 patients (69 eyes) aged 18 to 33 years with stage II-III KC. The study included patients who had previously undergone standard corneal collagen cross-linking. Depending on the type of optical correction, the patients were divided into two groups: patients in group 1 underwent ICRS implantation using a femtosecond laser; patients in group 2 were fitted with individual scleral RCLs. RESULTS: Improvement in clinical and functional parameters was observed in both groups. A higher clinical and functional result was achieved in group 2. CONCLUSION: For patients with stable stage II-III KC, it is advisable to recommend fitting of individual scleral RCLs for visual rehabilitation.


Asunto(s)
Lentes de Contacto , Queratocono , Esclerótica , Agudeza Visual , Humanos , Queratocono/cirugía , Queratocono/diagnóstico , Queratocono/fisiopatología , Queratocono/terapia , Femenino , Masculino , Adulto , Esclerótica/cirugía , Implantación de Prótesis/métodos , Implantación de Prótesis/instrumentación , Resultado del Tratamiento , Topografía de la Córnea , Prótesis e Implantes , Adulto Joven , Ajuste de Prótesis/métodos , Adolescente , Sustancia Propia/cirugía
2.
Vestn Oftalmol ; 140(2): 85-90, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38742503

RESUMEN

The introduction of early diagnostic methods for keratoconus into clinical practice has become the basis for the development of surgical treatment techniques for this pathology, such as corneal collagen crosslinking and interlamellar keratoplasty with implantation of intrastromal segments. The article analyzes the results of research by Russian and foreign specialists in these areas and presents the data on the combination of SMILE surgery and corneal crosslinking, the Rome protocol of corneal crosslinking, modifications of interlamellar keratoplasty, the use of femtosecond laser technologies, and some pilot studies. Modern requirements for ophthalmological care require a personalized approach to each patient, and therefore the surgeon should have a wide range of surgical methods of treatment applicable to different patient cohorts. The described methods of treatment, according to the authors, are the most promising.


Asunto(s)
Queratocono , Queratocono/cirugía , Queratocono/diagnóstico , Humanos , Córnea/cirugía , Córnea/diagnóstico por imagen , Trasplante de Córnea/métodos , Cirugía Laser de Córnea/métodos , Resultado del Tratamiento , Colágeno
3.
Transl Vis Sci Technol ; 13(5): 7, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38727695

RESUMEN

Purpose: Multiple clinical visits are necessary to determine progression of keratoconus before offering corneal cross-linking. The purpose of this study was to develop a neural network that can potentially predict progression during the initial visit using tomography images and other clinical risk factors. Methods: The neural network's development depended on data from 570 keratoconus eyes. During the initial visit, numerical risk factors and posterior elevation maps from Scheimpflug imaging were collected. Increase of steepest keratometry of 1 diopter during follow-up was used as the progression criterion. The data were partitioned into training, validation, and test sets. The first two were used for training, and the latter for performance statistics. The impact of individual risk factors and images was assessed using ablation studies and class activation maps. Results: The most accurate prediction of progression during the initial visit was obtained by using a combination of MobileNet and a multilayer perceptron with an accuracy of 0.83. Using numerical risk factors alone resulted in an accuracy of 0.82. The use of only images had an accuracy of 0.77. The most influential risk factors in the ablation study were age and posterior elevation. The greatest activation in the class activation maps was seen at the highest posterior elevation where there was significant deviation from the best fit sphere. Conclusions: The neural network has exhibited good performance in predicting potential future progression during the initial visit. Translational Relevance: The developed neural network could be of clinical significance for keratoconus patients by identifying individuals at risk of progression.


Asunto(s)
Topografía de la Córnea , Aprendizaje Profundo , Progresión de la Enfermedad , Queratocono , Queratocono/diagnóstico por imagen , Queratocono/diagnóstico , Humanos , Femenino , Masculino , Adulto , Topografía de la Córnea/métodos , Adulto Joven , Factores de Riesgo , Córnea/diagnóstico por imagen , Córnea/patología , Adolescente , Persona de Mediana Edad , Redes Neurales de la Computación
4.
Sci Rep ; 14(1): 9984, 2024 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-38693352

RESUMEN

The aim of this work is to quantitatively assess the wavefront phase of keratoconic eyes measured by the ocular aberrometer t·eyede (based on WaveFront Phase Imaging Sensor), characterized by a lateral resolution of 8.6 µm without requiring any optical element to sample the wavefront information. We evaluated the parameters: root mean square error, Peak-to-Valley, and amplitude of the predominant frequency (Fourier Transform analysis) of a section of the High-Pass filter map in keratoconic and healthy cohorts. Furthermore, we have analyzed keratoconic eyes that presented dark-light bands in this map to assess their period and orientation with the Fourier Transform. There are significant statistical differences (p value < 0.001) between healthy and keratoconic eyes in the three parameters, demonstrating a tendency to increase with the severity of the disease. Otherwise, the quantification of the bands reveals that the width is independent of eye laterality and keratoconic stage as orientation, which tends to be oblique. In conclusion, the quantitative results obtained with t·eyede could help to diagnose and monitor the progression of keratoconus.


Asunto(s)
Queratocono , Queratocono/diagnóstico por imagen , Queratocono/diagnóstico , Humanos , Adulto , Femenino , Masculino , Topografía de la Córnea/métodos , Adulto Joven , Aberrometría/métodos , Córnea/diagnóstico por imagen , Córnea/patología , Análisis de Fourier
5.
BMC Ophthalmol ; 24(1): 201, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38698363

RESUMEN

BACKGROUND: We aimed to employ Optical Coherence Tomography Angiography (OCTA) to comprehensively assess changes in the optic nerve head (ONH) and macular perfusion before and after the Corneal Collagen Cross-Linking (CCL) procedure in patients with keratoconus. METHODS: A total of 22 keratoconus patient's candidate for CCL procedures were included based on specific criteria, with meticulous exclusion criteria in place to minimize potential confounders. Participants underwent OCTA assessments of the ONH and macula using the Spectralis OCT (Heidelberg) before CCL, as well as at 1- and 3-months post-CCL. MATLAB software was utilized for image analysis. RESULTS: The mean age of the participants was 20.09 ± 6.11, including 59% male, and the mean intraocular pressure (IOP) before the surgery was 13.59 ± 2.85 mmHg. Peripapillary Retinal nerve fiber layer (ppRNFL) thickness and overall retinal thickness remained stable post-CCL. However, significant alterations were observed in macular vessel density, emphasizing regional variations in vascular response. For macular large vessel density (LVD), both superficial and deep vascular complex (SVC and DVC) demonstrated significant differences between before surgery and the 3 months post-surgery follow-up (p < 0.001 and p = 0.002, respectively). Optic nerve head markers demonstrated relative stability, except for changes in avascular complex density, which was 49.2 ± 2.2% before the surgery and decrease to 47.6 ± 1.7% three months after the operation (P-value = 0.005). CONCLUSION: While CCL appears to maintain the integrity of certain ocular structures, alterations in macular perfusion post-CCL suggest potential effects on retinal blood supply. Long-term monitoring is crucial to understand the implications of these changes, particularly in the context of conditions such as diabetes.


Asunto(s)
Colágeno , Reactivos de Enlaces Cruzados , Angiografía con Fluoresceína , Queratocono , Disco Óptico , Vasos Retinianos , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Queratocono/fisiopatología , Queratocono/diagnóstico , Masculino , Femenino , Colágeno/metabolismo , Adulto Joven , Adulto , Angiografía con Fluoresceína/métodos , Vasos Retinianos/diagnóstico por imagen , Vasos Retinianos/fisiopatología , Disco Óptico/irrigación sanguínea , Adolescente , Estudios Prospectivos , Fármacos Fotosensibilizantes/uso terapéutico , Fotoquimioterapia/métodos , Mácula Lútea/diagnóstico por imagen , Mácula Lútea/irrigación sanguínea
6.
Jpn J Ophthalmol ; 68(3): 225-232, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38557918

RESUMEN

PURPOSE: We aimed to compare the efficacy and safety of accelerated contact lens-assisted cross-linking (CA-CXL) with Lotrafilcon B and Comfilcon A lenses in keratoconus (KC) patients with thin corneas. STUDY DESIGN: Retrospective, single-center study. MATERIALS AND METHODS: We retrospectively included 51 eyes of 39 KC patients with corneal thickness <400µm after epithelial scraping (Epi-off), who underwent accelerated CA-CXL treatment with Lotrafilcon B (n=20) and Comfilcon A (n=31). Uncorrected and corrected distance visual acuity (UDVA and CDVA), manifest refraction values, corneal topographic data and endothelial cell density were recorded at preoperative and postoperative 1st, 3rd and 6th month controls. RESULTS: CDVA in the Comfilcon A group was higher than CDVA before surgery at 6 months postoperatively (p<0.001). When the two lenses were compared, CDVA was found to be significantly higher in the Lotrafilcon B group in the preoperative, postoperative 1st month and 3rd month values, but there was no significant difference between the postoperative 6th month values (p=0.028, p=0.018, p=0.044, p=0.181, respectively). The maximum keratometry (Kmax) value at the 6th month after surgery in the Comfilcon A group was significantly lower than in the Lotrafilcon B group (p=0,009). There was no significant difference between the endothelial cell density values between the groups (p=0.623, p=0.609, p=0.794, p=0.458, respectively). There was no significant difference between the progression, regression, and stability rates of the two groups (p=0.714). CONCLUSIONS: Accelerated CA-CXL with Lotrafilcon B and Comfilcon A silicone hydrogel lenses is a safe and effective method to stop progression in patients with thin corneas.


Asunto(s)
Colágeno , Topografía de la Córnea , Reactivos de Enlaces Cruzados , Queratocono , Fotoquimioterapia , Fármacos Fotosensibilizantes , Refracción Ocular , Riboflavina , Agudeza Visual , Humanos , Queratocono/diagnóstico , Queratocono/fisiopatología , Queratocono/tratamiento farmacológico , Queratocono/terapia , Queratocono/metabolismo , Femenino , Masculino , Estudios Retrospectivos , Agudeza Visual/fisiología , Fármacos Fotosensibilizantes/uso terapéutico , Adulto , Riboflavina/uso terapéutico , Fotoquimioterapia/métodos , Adulto Joven , Refracción Ocular/fisiología , Colágeno/metabolismo , Resultado del Tratamiento , Córnea/patología , Rayos Ultravioleta , Estudios de Seguimiento , Adolescente , Recuento de Células , Sustancia Propia/metabolismo , Endotelio Corneal/patología , Lentes de Contacto Hidrofílicos , Reticulación Corneal
7.
Indian J Ophthalmol ; 72(5): 712-717, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38648433

RESUMEN

PURPOSE: To compare the changes encountered in corneal biomechanics and aberration profile following accelerated corneal collagen cross-linking (CXL) using hypo-osmolar and iso-osmolar riboflavin in corneal thicknesses of <400 and >400 microns, respectively. METHODS: This is a prospective, interventional, comparative study involving 100 eyes of 75 patients with progressive keratoconus. Eyes were divided into two groups based on corneal thickness: group 1 included eyes with a corneal thickness of <400 microns who underwent hypo-osmolar CXL, and group 2 included eyes with a corneal thickness of >400 microns who underwent iso-osmolar CXL. Corneal biomechanical and aberration profiles were evaluated and compared between groups. RESULTS: In group 1, all higher-order aberrations (HOA) except secondary astigmatism significantly decreased from baseline; however, in group 2, only coma and trefoil decreased. The corneal resistance factor and corneal hysteresis significantly improved in both groups, which was significantly greater in group 2 than in group 1. The change in inverse radius, deformation amplitude, and tomographic biomechanical index was significantly improved in group 2 as compared to group 1. CONCLUSION: Improvement in corrected distance visual acuity and decrease in HOA were significantly better in the hypo-osmolar CXL group; however, the improvement in biomechanical strength of the cornea was significantly better in the iso-osmolar group.


Asunto(s)
Colágeno , Córnea , Topografía de la Córnea , Reactivos de Enlaces Cruzados , Queratocono , Fármacos Fotosensibilizantes , Riboflavina , Rayos Ultravioleta , Agudeza Visual , Adolescente , Adulto , Femenino , Humanos , Masculino , Adulto Joven , Fenómenos Biomecánicos , Colágeno/metabolismo , Córnea/diagnóstico por imagen , Córnea/fisiopatología , Córnea/efectos de los fármacos , Sustancia Propia/metabolismo , Sustancia Propia/efectos de los fármacos , Aberración de Frente de Onda Corneal/fisiopatología , Reactivos de Enlaces Cruzados/uso terapéutico , Estudios de Seguimiento , Queratocono/tratamiento farmacológico , Queratocono/fisiopatología , Queratocono/diagnóstico , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes/uso terapéutico , Estudios Prospectivos , Refracción Ocular/fisiología , Riboflavina/uso terapéutico , Agudeza Visual/fisiología , Niño
8.
Indian J Ophthalmol ; 72(Suppl 3): S495-S500, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38648457

RESUMEN

PURPOSE: This retrospective longitudinal study evaluated the biomechanical E-staging in KC corneas before and after intracorneal ring segment (ICRS) implantation (Intacs® SK, Addition Technology, Illinois, United States). METHODS: Biomechanical E-staging for ectatic corneal diseases was applied retrospectively on 49 KC corneas of 41 patients who underwent ICRS implantation. The main outcome parameters included the Corvis Biomechanical Factor (CBiF, the linearized Corvis Biomechanical Index and the biomechanical parameters included), the resulting biomechanical E-staging, the stress-strain index, thinnest corneal thickness (TCT), maximal anterior keratometry (Kmax), and the anterior radius of curvature (ARC). They were evaluated at 1.9 ± 1.1 months preoperatively and postoperatively after 2.8 ± 0.7, 5.8 ± 1.0, and 10.6 ± 2.3 months. RESULTS: The CBiF decreased (4.9 ± 0.5 | 4.7 ± 0.5, P = 0.0013), and the E-staging increased significantly (2.8 ± 0.8 | 3.1 ± 0.9, P = 0.0012, paired t-test) from preoperatively to the first postoperative follow-up. The difference remained significant after 6 months; however, there was no more difference after 11 months. TCT was stable, whereas Kmax and ARC significantly decreased after ICRS implantation (TCT: 464 ± 49, 470 ± 51, 467 ± 38, 461 ± 48; Kmax: 56.3 ± 4.5, 54.7 ± 4.5, 54.2 ± 4.8, 54.1 ± 4.3; ARC: 51.5 ± 3.4, 48.3 ± 3.8, 48.6 ± 3.0, 48.6 ± 3.2 preoperatively and 3, 6, and 11 months postoperatively, respectively). Besides Kmax and ARC, Ambrósio's relational thickness to the horizontal profile (ARTh) was the only parameter that was significantly lower than preoperatively at any follow-up (P ≤ 0.0024, Wilcoxon matched-pairs test). CONCLUSION: Intacs® SK implantation results in an increasing biomechanical E-staging in the first postoperative months with stabilization near preoperative values after 1 year. Significantly lower ARTh values at any follow-up document the ICRS effect and contribute to a slightly higher postoperative biomechanical E-staging value.


Asunto(s)
Córnea , Sustancia Propia , Topografía de la Córnea , Queratocono , Prótesis e Implantes , Implantación de Prótesis , Agudeza Visual , Humanos , Queratocono/cirugía , Queratocono/diagnóstico , Queratocono/fisiopatología , Estudios Retrospectivos , Femenino , Masculino , Adulto , Implantación de Prótesis/métodos , Córnea/patología , Estudios de Seguimiento , Sustancia Propia/patología , Sustancia Propia/cirugía , Agudeza Visual/fisiología , Fenómenos Biomecánicos , Adulto Joven , Persona de Mediana Edad , Refracción Ocular/fisiología , Diseño de Prótesis , Adolescente
9.
BMJ Open Ophthalmol ; 9(1)2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38653536

RESUMEN

OBJECTIVE: Our objective is to develop a novel keratoconus image classification system that leverages multiple pretrained models and a transformer architecture to achieve state-of-the-art performance in detecting keratoconus. METHODS AND ANALYSIS: Three pretrained models were used to extract features from the input images. These models have been trained on large datasets and have demonstrated strong performance in various computer vision tasks.The extracted features from the three pretrained models were fused using a feature fusion technique. This fusion aimed to combine the strengths of each model and capture a more comprehensive representation of the input images. The fused features were then used as input to a vision transformer, a powerful architecture that has shown excellent performance in image classification tasks. The vision transformer learnt to classify the input images as either indicative of keratoconus or not.The proposed method was applied to the Shahroud Cohort Eye collection and keratoconus detection dataset. The performance of the model was evaluated using standard evaluation metrics such as accuracy, precision, recall and F1 score. RESULTS: The research results demonstrated that the proposed model achieved higher accuracy compared with using each model individually. CONCLUSION: The findings of this study suggest that the proposed approach can significantly improve the accuracy of image classification models for keratoconus detection. This approach can serve as an effective decision support system alongside physicians, aiding in the diagnosis of keratoconus and potentially reducing the need for invasive procedures such as corneal transplantation in severe cases.


Asunto(s)
Queratocono , Queratocono/diagnóstico , Queratocono/clasificación , Humanos , Córnea/patología , Algoritmos , Topografía de la Córnea/métodos
10.
J Refract Surg ; 40(4): e253-e259, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38593262

RESUMEN

PURPOSE: To compare simulated keratometry (SimK) and total corneal power (TCP) in keratoconic eyes, to determine whether the differences are systematic and predictable and to evaluate an adjusted TCP-based formula for intraocular lens (IOL) power calculation. METHODS: In a consecutive series of keratoconic eyes, measurements of SimK, TCP, posterior keratometry, and anterior and posterior corneal asphericities (Q-values) were retrospectively collected. The difference between SimK and TCP was linearly correlated to the biometric parameters. In a separate sample of keratoconic eyes that had undergone cataract surgery, IOL power was calculated with the Barrett Universal II, Hoffer QST, Holladay 1, Kane, and SRK/T formulas using the SimK and an adjusted TCP power. The respective prediction errors were calculated. RESULTS: A total of 382 keratoconic eyes (271 patients) were enrolled. An increasing overestimation of SimK by TCP was detected from stage I to III, with a significant correlation between the SimK and TCP difference and SimK in the whole sample (P < .0001, r2 = 0.1322). Approximately 7% of cases presented an underestimation of SimK by TCP. IOL power calculation with the adjusted TCP improved outcomes, achieving a maximum of 80% of eyes with a prediction error within ±0.50 diopters with the Hoffer QST, Holladay 1, and Kane formulas. CONCLUSIONS: Overall, SimK overestimated TCP. Such a difference could not be predicted by any variable. The proposed TCP-adjustment formula (TCPadj = TCP + 0.56 diopters) in keratoconic eyes for IOL power calculation might be valuable for improving refractive outcomes. [J Refract Surg. 2024;40(4):e253-e259.].


Asunto(s)
Queratocono , Lentes Intraoculares , Facoemulsificación , Humanos , Queratocono/diagnóstico , Implantación de Lentes Intraoculares/métodos , Estudios Retrospectivos , Facoemulsificación/métodos , Óptica y Fotónica , Refracción Ocular , Biometría/métodos
11.
J Refract Surg ; 40(4): e260-e269, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38593263

RESUMEN

PURPOSE: To compare the parameters of three different topographic devices (Pentacam HR, Oculus Optikgeräte GmbH; Sirius, Costruzione Strumenti Oftalmici; and Cassini, i-Optics) in grading the severity of keratoconus in cross-linked and non-cross-linked eyes. METHODS: This was a prospective comparative interventional study done in a tertiary eye care center, wherein 114 eyes of 68 patients with keratoconus were divided into two groups: 62 eyes that were observed and 52 eyes that were cross-linked. All eyes were evaluated on all three topographers at baseline, 3-month follow-up, and 6-month follow-up. RESULTS: The Sirius showed significantly lower values of mean flat keratometry in comparison to the Pentacam HR (limits of agreement [LoA]: 1.75 to 3.51%) and Cassini (LoA: 1.75 to 3.51%). The mean steep keratometry values were higher for the Cassini in comparison to the Pentacam HR (LoA: 4.39 to 7.02%) and Sirius (LoA: 3.51 to 6.14%). The mean steep keratometry values of the Sirius were significantly lower than those of the Pentacam HR and in both the cross-linked and observation groups (LoA: 3.51 to 6.14%). The mean keratometry values were significantly higher in the Cassini compared to the Pentacam HR (LoA: 3.51 to 8.77%) and significantly lower in the Sirius in comparison to the Pentacam HR (LoA: 3.51 to 6.14%). The mean difference in astigmatism was also statistically significant between the three tomographers in both groups, with the Cassini showing higher values (LoA: 3.51 to 5.26%) and the Sirius lower values than the Pentacam HR (LoA: 5.26 to 6.14%). CONCLUSIONS: The authors conclude the three devices cannot be used interchangeably. The Cassini showed better agreement and correlation with the Pentacam HR in the staging of keratoconus, whereas the Sirius tended to underdiagnose and under-stage the disease. [J Refract Surg. 2024;40(4):e260-e269.].


Asunto(s)
Queratocono , Humanos , Queratocono/diagnóstico , Topografía de la Córnea , Estudios Prospectivos , Reproducibilidad de los Resultados , Córnea
12.
Int Ophthalmol ; 44(1): 172, 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38594548

RESUMEN

INTRODUCTION: Keratoconus is a progressive disorder of the cornea that causes thinning (Sedaghat et al. in Sci Rep 11(1):11971, 2021), ectasia, and irregular astigmatism, resulting in poor visual acuity that cannot be corrected with standard sphero-cylindrical spectacle lenses. One feature distinguishing keratoconic corneas is ocular aberrations, manifesting up to five or six times the amount of higher-order aberrations than a normal, healthy eye. These aberrations can cause visual disturbances even at the very early stages of the disease. METHODS: In the past, a diagnosis was derived from clinical symptoms, but technological advances have revealed multiple pre-clinical features, allowing for the differentiation between keratoconic and normal eyes at a much earlier stage. These include anterior and posterior corneal surface elevations, the corneal pachymetry profile, corneal epithelial patterns, wavefront aberration metrics, and corneal biomechanics (Sedaghat et al. in Sci Rep 11(1):11971, 2021).This review discusses the aberrations associated with keratoconus, how to measure them, and treatment methods to minimize their negative influence. CONCLUSIONS: Early diagnosis can lead to early treatment and may allow for arresting progression, thereby improving the long-term prognosis. With the acceleration of refractive surgery, it is important to identify patients with keratoconus, as they are usually contraindicated for refractive surgery.


Asunto(s)
Astigmatismo , Queratocono , Humanos , Queratocono/diagnóstico , Queratocono/etiología , Queratocono/terapia , Topografía de la Córnea/métodos , Córnea , Astigmatismo/diagnóstico , Trastornos de la Visión
13.
Int Ophthalmol ; 44(1): 132, 2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38478103

RESUMEN

PURPOSE: Corneal biomechanics is an emerging field and the interest into physical and biological interrelations in the anterior part of the eye has significantly increased during the past years. There are many factors that determine corneal biomechanics such as hormonal fluctuations, hydration and environmental factors. Other factors that can affect the corneas are the age, the intraocular pressure and the central corneal thickness. The purpose of this review is to evaluate the factors affecting corneal biomechanics and the recent advancements in non-destructive, in vivo measurement techniques for early detection and improved management of corneal diseases. METHODS: Until recently, corneal biomechanics could not be directly assessed in humans and were instead inferred from geometrical cornea analysis and ex vivo biomechanical testing. The current research has made strides in studying and creating non-destructive and contactless techniques to measure the biomechanical properties of the cornea in vivo. RESULTS: Research has indicated that altered corneal biomechanics contribute to diseases such as keratoconus and glaucoma. The identification of pathological corneas through the new measurement techniques is imperative for preventing postoperative complications. CONCLUSIONS: Identification of pathological corneas is crucial for the prevention of postoperative complications. Therefore, a better understanding of corneal biomechanics will lead to earlier diagnosis of ectatic disorders, improve current refractive surgeries and allow for a better postoperative treatment.


Asunto(s)
Córnea , Queratocono , Humanos , Fenómenos Biomecánicos , Queratocono/diagnóstico , Queratocono/cirugía , Presión Intraocular , Complicaciones Posoperatorias
14.
Comput Biol Med ; 172: 108286, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38493602

RESUMEN

PURPOSE: To ascertain whether the integration of raw Corvis ST data with an end-to-end CNN can enhance the diagnosis of keratoconus (KC). METHOD: The Corvis ST is a non-contact device for in vivo measurement of corneal biomechanics. The CorNet was trained and validated on a dataset consisting of 1786 Corvis ST raw data from 1112 normal eyes and 674 KC eyes. Each raw data consists of the anterior and posterior corneal surface elevation during air-puff induced dynamic deformation. The architecture of CorNet utilizes four ResNet-inspired convolutional structures that employ 1 × 1 convolution in identity mapping. Gradient-weighted Class Activation Mapping (Grad-CAM) was adopted to visualize the attention allocation to diagnostic areas. Discriminative performance was assessed using metrics including the AUC of ROC curve, sensitivity, specificity, precision, accuracy, and F1 score. RESULTS: CorNet demonstrated outstanding performance in distinguishing KC from normal eyes, achieving an AUC of 0.971 (sensitivity: 92.49%, specificity: 91.54%) in the validation set, outperforming the best existing Corvis ST parameters, namely the Corvis Biomechanical Index (CBI) with an AUC of 0.947, and its updated version for Chinese populations (cCBI) with an AUC of 0.963. Though the ROC curve analysis showed no significant difference between CorNet and cCBI (p = 0.295), it indicated a notable difference between CorNet and CBI (p = 0.011). The Grad-CAM visualizations highlighted the significance of corneal deformation data during the loading phase rather than the unloading phase for KC diagnosis. CONCLUSION: This study proposed an end-to-end CNN approach utilizing raw biomechanical data by Corvis ST for KC detection, showing effectiveness comparable to or surpassing existing parameters provided by Corvis ST. The CorNet, autonomously learning comprehensive temporal and spatial features, demonstrated a promising performance for advancing KC diagnosis in ophthalmology.


Asunto(s)
Queratocono , Humanos , Queratocono/diagnóstico , Topografía de la Córnea , Córnea/diagnóstico por imagen , Curva ROC , Fenómenos Biomecánicos
15.
Int Ophthalmol ; 44(1): 145, 2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38498219

RESUMEN

PURPOSE: To compare the visual, refractive, and topographic outcomes of a high irradiance accelerated corneal crosslinking (ACXL) protocol after a 12-month follow-up between pediatric and adult patients with progressive keratoconus (KC). METHODS: Retrospective, comparative, cohort study. Patients with KC were divided into two groups: pediatric (≤ 18 years) and adult (> 18 years). All of them were managed with epi-OFF ACXL (30 mW/cm2, 8 min, pulsed 1:1 on and off = 7.2 J/cm2). Visual, refractive, and topographic values were measured preoperatively and at 1, 3, 6, and 12 months postoperative. KC progression, defined as a Kmax increase of ≥ 1D during follow-up, was recorded. RESULTS: Eighty-nine eyes (53 patients) were included for analysis; 45 (50.6%) eyes were from pediatric patients and 44 (49.4%) from adults. At one-year follow-up, pediatric patients experienced significantly higher rates of progression (22.2% vs. 4.5%, p = .014). Contrariwise, female gender (Beta = - 3.62, p = .018), a baseline uncorrected visual acuity of Snellen ≥ 20/60 (Beta = - 5.96, p = .007), and being ≥ 15 years at ACXL treatment (Beta = - 0.31, p = .021) were associated with non-progressive disease. A significant improvement in best-corrected visual acuity, Kmin, Km, and Kmax was recorded in both groups. Overall, 86.5% of eyes from both groups showed Kmax stabilization or improvement. CONCLUSIONS: Despite the similarity in visual, refractive, and topographic outcomes in both groups, younger age was associated with KC progression after ACXL at one year of follow-up.


Asunto(s)
Queratocono , Fotoquimioterapia , Adulto , Humanos , Femenino , Niño , Queratocono/diagnóstico , Queratocono/tratamiento farmacológico , Fármacos Fotosensibilizantes/uso terapéutico , Fotoquimioterapia/métodos , Reticulación Corneal , Estudios Retrospectivos , Estudios de Cohortes , Riboflavina/uso terapéutico , Rayos Ultravioleta , Topografía de la Córnea/métodos , Estudios de Seguimiento , Reactivos de Enlaces Cruzados/uso terapéutico , Colágeno/uso terapéutico
16.
Int Ophthalmol ; 44(1): 146, 2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38499839

RESUMEN

PURPOSE: To evaluate the effect of transepithelial corneal collagen crosslinking (CXL) treatment on the optical performance of the cornea at 12-month follow-up after CXL in patients with progressive keratoconus. METHODS: One hundred and ten eyes of 67 patients were included. The following corneal optical aberrations over the 4-mm-diameter pupil were recorded via Sirius dual-scanning corneal tomography: total, anterior and posterior amount of corneal higher order aberrations [HOAs], vertical coma, horizontal coma, vertical trefoil, oblique trefoil, and spherical aberration, and Strehl ratio of point spread function (PSF). RESULTS: There were significant improvements in mean root mean square error values for corneal total HOA, total coma, anterior HOA, anterior coma, and vertical coma following CXL (P > 0.05, for all). No significant changes were found in the posterior aberometric parameters. PSF value did not change after CXL (P > 0.05). The corneal topographic measurements not revealed a change in the mean simulated keratometry-1, simulated keratometry-2, and maximum keratometry compared with the baseline measurements (P > 0.05, for all). At 12 months, there was a significant improvement in the uncorrected (UCVA) and best corrected (BCVA) visual acuity (P < 0.001, both). Most corneal aberrations correlated significantly with postoperative BCVA, but changes in HOAs were not statistically associated with improvements in visual acuity. CONCLUSIONS: Transepithelial CXL was effective in stabilizing the keratometric indices and improving the most corneal aberrations in keratoconic eyes 1 year after the procedure. While the healing effect on aberrations after CXL was in total and anterior parameters, no significant changes were observed in the posterior surface. In addition, it was observed that transepithelial CXL treatment did not cause a significant change in PSF distribution data.


Asunto(s)
Queratocono , Fotoquimioterapia , Humanos , Queratocono/diagnóstico , Queratocono/tratamiento farmacológico , Reticulación Corneal , Coma , Fármacos Fotosensibilizantes/uso terapéutico , Riboflavina/uso terapéutico , Córnea , Topografía de la Córnea , Fotoquimioterapia/métodos , Colágeno/uso terapéutico , Reactivos de Enlaces Cruzados/uso terapéutico , Rayos Ultravioleta
17.
Afr J Prim Health Care Fam Med ; 16(1): e1-e11, 2024 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-38426773

RESUMEN

BACKGROUND: Keratoconus (KC) is a progressive condition that usually affects young persons between their first and fourth decades. Myopia and irregular astigmatism are the common presentations which are proceeded by corneal steepening and thinning. Keratoconus is a progressive ectasia of the cornea that presents bilaterally, although often asymmetrical. AIM: To explore the experiences of KC patients attending public eye care facilities in Capricorn District of Limpopo province. SETTING: Capricorn District, Limpopo province, South Africa. METHODS: Descriptive qualitative phenomenology approach was used in the study to explore the lived experiences of patients diagnosed with KC, attending public eye care facilities. Purposive sampling was used to select 16 patients who were diagnosed with KC and referred for contact lens fitting. Data were collected through face-to-face, one-on-one interviews. RESULTS: Patients reported to have developed gradual vision loss which worsened when they grew older. There was lack of knowledge of KC amongst patients and this was exacerbated by limited health literacy and vocabulary barriers. Patients had difficulty performing daily activities where some had dropped out of school while others worked at a slower pace and reduced working distances. CONCLUSION: Patients with KC received inadequate information on their condition due to limited health literacy and vocabulary barriers. Programmes to promote practitioner and patient education are required to improve the perceived service level provided to KC patients.Contribution: The findings of this study will assist to improve the experiences of KC patients on perceived service quality received from public facilities.


Asunto(s)
Queratocono , Humanos , Queratocono/diagnóstico , Sudáfrica , Instalaciones Públicas , Córnea
18.
Eur J Ophthalmol ; 34(3): 649-655, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38425220

RESUMEN

PURPOSE: To estimate the prevalence of keratoconus in a population of subjects undergoing first eye examination in an eye clinic in Italy. METHODS: A single-center, cross-sectional, study was conducted involving patients who underwent first eye examination at an eye clinic in Rome between September 2021 and June 2022. The prevalence of keratoconus was determined by Placido-disk corneal topography using the maximum keratometry (Kmax) value and the Cone Magnitude and Location Index (CLMI) for keratoconus screening. Subjective analysis was performed by two experienced corneal specialists, who classified the outcome into two groups: normal and keratoconus. Risk factors, including family history of keratoconus, allergy or atopy, thyroid disease, eye rubbing habit and gender were also examined. RESULTS: A total of 512 subjects between 7 and 81 years old were evaluated. The inter-observer agreement to classify subjects in normal or keratoconus group was excellent (k = 1.0); the estimated prevalence in the specific population was 2.1%. Presence of positive family history (9% of keratoconus vs 5% normal), concomitant allergy or atopy (27% vs 9%) and eye rubbing habit (18% vs 4%) were associated with a higher risk of disease. CONCLUSION: This study reported a high estimated prevalence of keratoconus in a metropolitan area of Italy, as found in recent studies in the Mediterranean and Middle East countries. Screening for keratoconus is highly recommendable and easily feasible with corneal topography under expert supervision and may be indicated primarily in young population to improve early detection and prompt therapeutic management for halting disease progression.


Asunto(s)
Topografía de la Córnea , Queratocono , Humanos , Queratocono/epidemiología , Queratocono/diagnóstico , Prevalencia , Femenino , Masculino , Estudios Transversales , Adulto , Persona de Mediana Edad , Niño , Adolescente , Anciano , Adulto Joven , Anciano de 80 o más Años , Italia/epidemiología , Factores de Riesgo , Población Urbana/estadística & datos numéricos , Córnea/patología , Distribución por Edad
20.
Indian J Ophthalmol ; 72(4): 495-507, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38317314

RESUMEN

Acute corneal hydrops (ACH) is a rare but sight-threatening complication of corneal ectasias. We aim to review the current literature on etiopathogenesis, histology, role of ancillary investigations, management, and outcomes of ACH by classifying the various management strategies based on their site of action and the underlying mechanism. A review of the literature was conducted by searching the following databases: PubMed (United States National Library of Medicine), Embase (Reed Elsevier Properties SA), Web of Science (Thomson Reuters), and Scopus (Elsevier BV) till April 2023. The literature search used various combinations of the following keywords: acute corneal hydrops, keratoconus, ectasia, management, keratoplasty. Nine hundred eighty-three articles were identified based on the above searches. Case reports which did not add any new modality of treatment to the existing literature, articles unrelated to management, those with no full text available, and foreign-language articles with no translation available were excluded. Eventually, 75 relevant articles that pertained to the management of ACH were shortlisted and reviewed. Recent studies have described newer surgical interventions like full-thickness or pre-Descemetic sutures, thermokeratoplasty, and plasma injection that aim to close the posterior stromal break. Posterior lamellar keratoplasties act by replacing the posterior torn Descemet's membrane (DM), and early deep anterior lamellar keratoplasty (DALK) has been attempted to combine the correction of the anatomical defect and visual rehabilitation in a single surgery. These surgical interventions may help by reducing the scarring and increasing the number of patients who can be visually rehabilitated with contact lenses rather than keratoplasty.


Asunto(s)
Edema Corneal , Trasplante de Córnea , Queratocono , Humanos , Edema Corneal/diagnóstico , Edema Corneal/etiología , Edema Corneal/terapia , Trasplante de Córnea/efectos adversos , Córnea , Queratocono/complicaciones , Queratocono/diagnóstico , Queratocono/cirugía , Edema
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...