Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 322
Filtrar
2.
J Vasc Interv Radiol ; 32(5): 677-682, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33933250

RESUMEN

In the merit-based incentive payment system (MIPS), quality measures are considered topped out if national median performance rates are ≥95%. Quality measures worth 10 points can be capped at 7 points if topped out for ≥2 years. This report compares the availability of diagnostic radiology (DR)-related and interventional radiology (IR)-related measures worth 10 points. A total of 196 MIPS clinical quality measures were reviewed on the Center for Medicare and Medicaid Services MIPS website. There are significantly more IR-related measures worth 10 points than DR measures (2/9 DR measures vs 9/12 IR measures; P = .03), demonstrating that clinical IR services can help mixed IR/DR groups maximize their Center for Medicare and Medicaid Services payment adjustment.


Asunto(s)
Benchmarking/economía , Diagnóstico por Imagen/economía , Costos de la Atención en Salud , Indicadores de Calidad de la Atención de Salud/economía , Radiografía Intervencional/economía , Radiología Intervencionista/economía , Benchmarking/normas , Centers for Medicare and Medicaid Services, U.S./economía , Diagnóstico por Imagen/normas , Costos de la Atención en Salud/normas , Humanos , Planes de Incentivos para los Médicos/economía , Indicadores de Calidad de la Atención de Salud/normas , Radiografía Intervencional/normas , Radiología Intervencionista/normas , Reembolso de Incentivo/economía , Estados Unidos
8.
J Cardiovasc Comput Tomogr ; 15(1): 2-15, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33032977

RESUMEN

Cardiovascular computed tomography (CCT) is a well-validated non-invasive imaging tool with an ever-expanding array of applications beyond the assessment of coronary artery disease. These include the evaluation of structural heart diseases, congenital heart diseases, peri-procedural electrophysiology applications, and the functional evaluation of ischemia. This breadth requires a robust and diverse training curriculum to ensure graduates of CCT training programs meet minimum competency standards for independent CCT interpretation. This statement from the Society of Cardiovascular Computed Tomography aims to supplement existing societal training guidelines by providing a curriculum and competency framework to inform the development of a comprehensive, integrated training experience for cardiology and radiology trainees in CCT.


Asunto(s)
Cardiólogos/educación , Cardiología/educación , Educación de Postgrado en Medicina , Radiografía Intervencional , Radiólogos/educación , Radiología Intervencionista/educación , Tomografía Computarizada por Rayos X , Cardiólogos/normas , Cardiología/normas , Competencia Clínica , Consenso , Curriculum , Educación de Postgrado en Medicina/normas , Humanos , Radiografía Intervencional/normas , Radiólogos/normas , Radiología Intervencionista/normas , Especialización , Tomografía Computarizada por Rayos X/normas
9.
Tech Vasc Interv Radiol ; 23(3): 100696, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33308526

RESUMEN

There are active debates surrounding patient evaluation and procedural techniques of prostate artery embolization. This review evaluates the available evidence on the value of urodynamics, the effect of prostate gland size, the benefits of pre- and intraprocedural cross-sectional imaging, the utility of a balloon-occlusion microcatheter, the differences among embolic particle sizes and types, and the merits of radial versus femoral arterial access.


Asunto(s)
Embolización Terapéutica/normas , Síntomas del Sistema Urinario Inferior/terapia , Próstata/irrigación sanguínea , Hiperplasia Prostática/terapia , Radiografía Intervencional/normas , Toma de Decisiones Clínicas , Embolización Terapéutica/efectos adversos , Humanos , Síntomas del Sistema Urinario Inferior/diagnóstico por imagen , Síntomas del Sistema Urinario Inferior/fisiopatología , Masculino , Selección de Paciente , Hiperplasia Prostática/diagnóstico por imagen , Hiperplasia Prostática/fisiopatología , Calidad de Vida , Radiografía Intervencional/efectos adversos , Recuperación de la Función , Factores de Riesgo , Resultado del Tratamiento , Urodinámica
10.
Tech Vasc Interv Radiol ; 23(3): 100695, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33308532

RESUMEN

Medically refractory benign prostatic hyperplasia induced lower urinary tract symptoms is an extremely prevalent issue in older men. The current gold standard therapy transurethral resection of the prostate does produce urologic improvements but is also associated with higher than desired morbidity. This has led to the need to develop new minimally invasive means to treat this disease; prostate artery embolization (PAE) has emerged as one minimally invasive treatment option for these patients. The body of evidence which supports the use of PAE has grown quickly and substantially over the last decade. The goal of this review is to introduce and summarize the published urologic outcomes for PAE when utilized to treat benign prostatic hyperplasia induced lower urinary tract symptoms as well as document the established complication profile. Finally, the paper reviews current societal recommendations as they relate to PAE.


Asunto(s)
Embolización Terapéutica/normas , Medicina Basada en la Evidencia/normas , Síntomas del Sistema Urinario Inferior/terapia , Guías de Práctica Clínica como Asunto/normas , Próstata/irrigación sanguínea , Hiperplasia Prostática/terapia , Radiografía Intervencional/normas , Embolización Terapéutica/efectos adversos , Humanos , Síntomas del Sistema Urinario Inferior/diagnóstico por imagen , Síntomas del Sistema Urinario Inferior/fisiopatología , Masculino , Hiperplasia Prostática/diagnóstico por imagen , Hiperplasia Prostática/fisiopatología , Calidad de Vida , Radiografía Intervencional/efectos adversos , Recuperación de la Función , Resultado del Tratamiento , Urodinámica
12.
Br J Radiol ; 93(1116): 20200814, 2020 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-32822543

RESUMEN

Notwithstanding that 100 mSv is not a threshold for radiation effects, cumulative effective dose (CED) for patients of ≥100 mSv derived from recurrent imaging procedures with ionising radiation has been recently the topic of several publications. The International Commission on Radiological Protection has alerted on the problems to use effective dose for risk estimation in individual patients but has accepted to use this quantity for comparison the relative radiation risks between different imaging modalities. A new International Commission on Radiological Protection document on the use of effective dose (including medicine), is in preparation. Recently published data on the number of patients with CED ≥100 mSv ranged from 0.6 to 3.4% in CT and around 4% in interventional radiology. The challenges to manage the existing situation are summarised. The main aspects identified are: 1) New technology with dose reduction techniques. 2) Refinements in the application of the justification and optimisation for these groups of patients. 3) Patient dose management systems with alerts on the cumulative high doses. 4) Education on the proper use of cumulative effective dose for referrers and practitioners including information for patients. 5) Future research programmes in radiation biology and epidemiology may profit the patient dose data from the groups with high cumulative dose values.


Asunto(s)
Dosis de Radiación , Protección Radiológica , Radiografía Intervencional/normas , Tomografía Computarizada por Rayos X/normas , Humanos , Protección Radiológica/normas
13.
AJR Am J Roentgenol ; 215(6): 1499-1503, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32442029

RESUMEN

OBJECTIVE. The purpose of this article is to present strategies and guidelines that can be implemented in the performance of cross-sectional interventional procedures during the coronavirus disease (COVID-19) pandemic. CONCLUSION. Radiologists who perform cross-sectional interventional procedures can take several steps to minimize the risks to patients and radiology personnel, including screening referred patients to decide which procedures can be postponed, using appropriate personal protective equipment (PPE), minimizing the number of people involved in procedures, preserving PPE when possible, and applying proper room and equipment cleaning measures.


Asunto(s)
COVID-19/prevención & control , Control de Infecciones/normas , Radiografía Intervencional/normas , Servicio de Radiología en Hospital/normas , COVID-19/epidemiología , Guías como Asunto , Humanos , Pandemias , Selección de Paciente , Equipo de Protección Personal , SARS-CoV-2 , Estados Unidos/epidemiología
14.
Eur Radiol ; 30(10): 5690-5701, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32361774

RESUMEN

OBJECTIVES: To establish national reference levels (RLs) in interventional procedures under CT guidance as required by the 2013/59/Euratom European Directive. METHODS: Seventeen categories of interventional procedures in thoracic, abdominopelvic, and osteoarticular specialties (percutaneous infiltration, vertebroplasty, biopsy, drainage, tumor destruction) were analyzed. Total dose length product (DLP), number of helical acquisitions (NH), and total DLP for helical, sequential, or fluoroscopic acquisitions were recorded for 10 to 20 patients per procedure at each center. RLs were calculated as the 3rd quartiles of the distributions and target values for optimization process (TVOs) as the median. RLs and TVOs were compared with previously published studies. RESULTS: Results on 5001 procedures from 49 centers confirmed the great variability in patient dose for the same category of procedures. RLs were proposed for the DLPs and NHs in the seventeen categories. RLs in terms of DLP and NH were 375 mGy.cm and 2 NH for spinal or peri-spinal infiltration, 1630 mGy.cm and 3 NH for vertebroplasty, 845 mGy.cm and 4 NH for biopsy, 1950 mGy.cm and 8 NH for destruction of tumors, and 1090 mGy.cm and 5 NH for drainage. DLP and NH increased with the complexity of procedures. CONCLUSIONS: This study was the first nationwide multicentric survey to propose RLs for interventional procedures under CT guidance. Heterogeneity of practice in centers were found with different levels of patient doses for the same procedure. The proposed RLs will allow imaging departments to benchmark their practice with others and optimize their protocols. KEY POINTS: • National reference levels are proposed for 17 categories of interventional procedures under CT guidance. • Reference levels are useful for benchmarking practices and optimizing protocols. • Reference levels are proposed for dose length product and the number of helical acquisitions.


Asunto(s)
Dosis de Radiación , Radiografía Intervencional/normas , Valores de Referencia , Tomografía Computarizada por Rayos X/normas , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Biopsia , Femenino , Fluoroscopía/métodos , Francia , Humanos , Masculino , Persona de Mediana Edad , Radiografía Intervencional/métodos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Columna Vertebral , Encuestas y Cuestionarios , Tomografía Computarizada por Rayos X/métodos , Vertebroplastia , Adulto Joven
16.
J Neurointerv Surg ; 12(10): 1014-1017, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32024785

RESUMEN

BACKGROUND: The prevalence of women physicians is steadily rising, but the field of neurointervention remains one of the most male-dominated subspecialties in medicine. A fear of radiation exposure, particularly during pregnancy and childbearing years, may be responsible for deterring some of the best and brightest. This is the first study to examine the amount of maternal and fetal radiation exposure during a pregnant neurointerventional fellow's training. METHODS: We retrospectively analyzed the radiation exposure of a neurointerventional fellow prior to and during pregnancy from February 2018 to May 2019 in 758 neurointerventional cases. The collar dosimeter was used to measure overall maternal exposure and an additional fetal dosimeter was worn under two lead apron skirts to estimate fetal radiation exposure. RESULTS: There was not a significant difference between pre- and post-pregnancy overall maternal radiation exposure as measured by the collar dosimeter (151 mrem pre-pregnancy and 105 mrem during pregnancy, p=0.129). Mean fluoroscopy time and fluoroscopy emission per procedure also did not differ prior to and during pregnancy. Fetal radiation exposure measurements from both the Mirion Genesis Ultra TLD dosimeter as well as the Mirion Instadose dosimeters worn under double lead apron skirts were 0 mrem for all 6 months. CONCLUSION: These findings suggest that, when optimal radiation safety practices are implemented, the fetal dose of a pregnant neurointerventionalist is negligible. Further studies and education are necessary to encourage women to choose neurointervention and allow practicing women neurointerventionalists to maintain their productivity during their reproductive years.


Asunto(s)
Exposición Profesional/prevención & control , Médicos , Dosis de Radiación , Exposición a la Radiación/prevención & control , Protección Radiológica/métodos , Radiografía Intervencional/métodos , Femenino , Fluoroscopía/efectos adversos , Humanos , Exposición Profesional/efectos adversos , Médicos/normas , Embarazo , Efectos Tardíos de la Exposición Prenatal/diagnóstico , Efectos Tardíos de la Exposición Prenatal/etiología , Efectos Tardíos de la Exposición Prenatal/prevención & control , Exposición a la Radiación/efectos adversos , Exposición a la Radiación/normas , Protección Radiológica/normas , Radiografía Intervencional/efectos adversos , Radiografía Intervencional/normas , Estudios Retrospectivos
18.
Radiography (Lond) ; 26(2): 163-166, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32052766

RESUMEN

INTRODUCTION: To evaluate the technical success, radiation dose, complications and costs from the introduction of a radiographer-led nephrostomy exchange service. METHODS: Post-graduate qualified interventional radiographers with several years' experience in performing other interventional procedures began performing nephrostomy exchanges. Training was provided by an interventional radiologist. Each radiographer performed ten procedures under direct supervision followed by independent practice with remote supervision. Each radiographer was then responsible for the radiological report, discharge, re-referral for further exchange and, where indicated, sending urine samples for culture and sensitivity. Data extraction included the time interval between exchanges, radiation dose/screening time and complications. RESULTS: Thirty-eight long-term nephrostomy patients had their histories interrogated back to the time of the initial insertion. The mean (range) age at nephrostomy insertion was 67 (35-93) years and 65% were male. Indications for nephrostomy were prostatic or gynaecological malignancy, ureteric injury, bulky lymphoma and post-transplant ureteric stricture. A total of 170 nephrostomy exchanges were performed with no statistically significant differences in the radiation dose, fluoroscopy time nor complication rates between consultants and radiographers. There was, however, a statistically significant reduction in the time interval between nephrostomy exchanges for the radiographer group (P = 0.022). CONCLUSION: Interventional radiographers can provide a safe, technically successful nephrostomy exchange program with radiation doses equivalent to radiologists. This is a cost-effective solution to the capacity issues faced in many departments, whilst providing career progression, job satisfaction and possibly improved care. IMPLICATIONS FOR PRACTICE: Radiographer-led interventional services should be considered by other institutions as a means of providing effective nephrostomy exchanges.


Asunto(s)
Técnicos Medios en Salud/normas , Nefrostomía Percutánea/normas , Radiografía Intervencional/normas , Radiólogos/normas , Adulto , Anciano , Anciano de 80 o más Años , Técnicos Medios en Salud/economía , Competencia Clínica , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Nefrostomía Percutánea/economía , Dosis de Radiación , Radiografía Intervencional/economía , Radiólogos/economía , Factores de Tiempo
19.
Phys Med ; 70: 169-175, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32032801

RESUMEN

The aim of this study is to propose national diagnostic reference levels (DRL) for updating in the field of interventional cardiology and to include technical details to help plan optimization. Medical physics experts and interventional cardiologists from 14 hospitals provided patient dose indicators from coronary angiography and percutaneous coronary interventions. Information about X-ray system dose settings and image quality was also provided. The dose values from 30,024 procedures and 26 interventional laboratories were recorded. The national DRLs proposed for coronary angiography and percutaneous coronary interventions were respectively 39 and 78 Gy·cm2 for air kerma area product (PKA), 530 and 1300 mGy for air kerma at reference point (Ka,r), 6.7 and 15 min of fluoroscopy time and 760 and 1300 cine images. 36% of the KAP meters required correction factors from 10 to 35%. The dose management systems should allow these corrections to be included automatically. The dose per image in cine in reference conditions differed in a factor of 5.5. Including X-ray system dose settings in the methodology provides an insight into the differences between hospitals. The DRLs proposed for Spain in this work were similar to those proposed in the last European survey. The poor correlation between X-ray systems dose settings and patient dose indicators highlights that other factors such as operation protocols and complexity may have more impact in patient dose indicators, which allows a wide margin for optimization. Dose reduction technology together with appropriate training programs will be determinant in the future reduction of patient dose indicators.


Asunto(s)
Angiografía Coronaria/normas , Intervención Coronaria Percutánea/normas , Dosis de Radiación , Radiografía Intervencional/normas , Radioterapia/métodos , Fluoroscopía , Humanos , Estándares de Referencia , Valores de Referencia , España , Encuestas y Cuestionarios
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...