Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.591
Filtrar
1.
Cancer Imaging ; 24(1): 57, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38711135

RESUMEN

BACKGROUND: PSMA PET/CT is a predictive and prognostic biomarker for determining response to [177Lu]Lu-PSMA-617 in patients with metastatic castration resistant prostate cancer (mCRPC). Thresholds defined to date may not be generalizable to newer image reconstruction algorithms. Bayesian penalized likelihood (BPL) reconstruction algorithm is a novel reconstruction algorithm that may improve contrast whilst preventing introduction of image noise. The aim of this study is to compare the quantitative parameters obtained using BPL and the Ordered Subset Expectation Maximization (OSEM) reconstruction algorithms. METHODS: Fifty consecutive patients with mCRPC who underwent [68Ga]Ga-PSMA-11 PET/CT using OSEM reconstruction to assess suitability for [177Lu]Lu-PSMA-617 therapy were selected. BPL algorithm was then used retrospectively to reconstruct the same PET raw data. Quantitative and volumetric measurements such as tumour standardised uptake value (SUV)max, SUVmean and Molecular Tumour Volume (MTV-PSMA) were calculated on both reconstruction methods. Results were compared (Bland-Altman, Pearson correlation coefficient) including subgroups with low and high-volume disease burdens (MTV-PSMA cut-off 40 mL). RESULTS: The SUVmax and SUVmean were higher, and MTV-PSMA was lower in the BPL reconstructed images compared to the OSEM group, with a mean difference of 8.4 (17.5%), 0.7 (8.2%) and - 21.5 mL (-3.4%), respectively. There was a strong correlation between the calculated SUVmax, SUVmean, and MTV-PSMA values in the OSEM and BPL reconstructed images (Pearson r values of 0.98, 0.99, and 1.0, respectively). No patients were reclassified from low to high volume disease or vice versa when switching from OSEM to BPL reconstruction. CONCLUSIONS: [68Ga]Ga-PSMA-11 PET/CT quantitative and volumetric parameters produced by BPL and OSEM reconstruction methods are strongly correlated. Differences are proportional and small for SUVmean, which is used as a predictive biomarker. Our study suggests that both reconstruction methods are acceptable without clinical impact on quantitative or volumetric findings. For longitudinal comparison, committing to the same reconstruction method would be preferred to ensure consistency.


Asunto(s)
Algoritmos , Teorema de Bayes , Isótopos de Galio , Radioisótopos de Galio , Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata Resistentes a la Castración , Humanos , Masculino , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Neoplasias de la Próstata Resistentes a la Castración/diagnóstico por imagen , Neoplasias de la Próstata Resistentes a la Castración/patología , Anciano , Persona de Mediana Edad , Estudios Retrospectivos , Oligopéptidos , Ácido Edético/análogos & derivados , Imagen de Cuerpo Entero/métodos , Radiofármacos , Anciano de 80 o más Años , Metástasis de la Neoplasia , Procesamiento de Imagen Asistido por Computador/métodos , Dipéptidos/uso terapéutico
2.
Cancer Imaging ; 24(1): 56, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38702821

RESUMEN

BACKGROUND: This study aimed to compare the diagnostic value of [68 Ga]Ga-DOTA-FAPI-04 and [18F]FDG PET/CT imaging for primary lesions and metastatic lymph nodes in patients with tonsil cancer. METHOD: Twenty-one tonsil cancer patients who underwent [68 Ga]Ga-DOTA-FAPI-04 and [18F]FDG PET/CT scans within two weeks in our centre were retrospectively enrolled. The maximum standardized uptake value (SUVmax) and tumor-to-background ratio (TBR) of the two tracers were compared by using the Mann‒Whitney U test. In addition, the sensitivity, specificity, and accuracy of the two methods for diagnosing metastatic lymph nodes were analysed. RESULTS: In detecting primary lesions, the efficiency was higher for [68 Ga]Ga-DOTA-FAPI-04 PET/CT (20/22) than for [18F]FDG PET/CT (9/22). Although [68 Ga]Ga-DOTA-FAPI-04 uptake (SUVmax, 5.03 ± 4.06) was lower than [18F]FDG uptake (SUVmax, 7.90 ± 4.84, P = 0.006), [68 Ga]Ga-DOTA-FAPI-04 improved the distinction between the primary tumor and contralateral normal tonsillar tissue. The TBR was significantly higher for [68 Ga]Ga-DOTA-FAPI-04 PET/CT (3.19 ± 2.06) than for [18F]FDG PET/CT (1.89 ± 1.80) (p < 0.001). In lymph node analysis, SUVmax and TBR were not significantly different between [68 Ga]Ga-DOTA-FAPI-04 and [18F]FDG PET/CT (7.67 ± 5.88 vs. 8.36 ± 6.15, P = 0.498 and 5.56 ± 4.02 vs. 4.26 ± 3.16, P = 0.123, respectively). The specificity and accuracy of [68 Ga]Ga-DOTA-FAPI-04 PET/CT were higher than those of [18F]FDG PET/CT in diagnosing metastatic cervical lymph nodes (all P < 0.05). CONCLUSION: The availability of [68 Ga]Ga-DOTA-FAPI-04 complements the diagnostic results of [18F]FDG by improving the detection rate of primary lesions and the diagnostic accuracy of cervical metastatic lymph nodes in tonsil cancer compared to [18F]FDG.


Asunto(s)
Fluorodesoxiglucosa F18 , Metástasis Linfática , Tomografía Computarizada por Tomografía de Emisión de Positrones , Radiofármacos , Neoplasias Tonsilares , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Masculino , Femenino , Estudios Retrospectivos , Metástasis Linfática/diagnóstico por imagen , Persona de Mediana Edad , Anciano , Neoplasias Tonsilares/diagnóstico por imagen , Neoplasias Tonsilares/patología , Adulto , Radioisótopos de Galio , Compuestos Organometálicos , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/patología
3.
World J Urol ; 42(1): 285, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38695883

RESUMEN

PURPOSE: This study is to investigate the diagnostic value of 68Ga-PSMA-11 in improving the concordance between mpMRI-TB and combined biopsy (CB) in detecting PCa. METHODS: 115 consecutive men with 68Ga-PSMA-11 PET/CT prior to prostate biopsy were included for analysis. PSMA intensity, quantified as maximum standard uptake value (SUVmax), minimum apparent diffusion coefficient (ADCmin) and other clinical characteristics were evaluated relative to biopsy concordance using univariate and multivariate logistic regression analyses. A prediction model was developed based on the identified parameters, and a dynamic online diagnostic nomogram was constructed, with its discrimination evaluated through the area under the ROC curve (AUC) and consistency assessed using calibration plots. To assess its clinical applicability, a decision curve analysis (DCA) was performed, while internal validation was conducted using bootstrapping methods. RESULTS: Concordance between mpMRI-TB and CB occurred in 76.5% (88/115) of the patients. Multivariate logistic regression analyses performed that SUVmax (OR= 0.952; 95% CI 0.917-0.988; P= 0.010) and ADCmin (OR= 1.006; 95% CI 1.003-1.010; P= 0.001) were independent risk factors for biopsy concordance. The developed model showed a sensitivity, specificity, accuracy and AUC of 0.67, 0.78, 0.81 and 0.78 in the full sample. The calibration curve demonstrated that the nomogram's predicted outcomes closely resembled the ideal curve, indicating consistency between predicted and actual outcomes. Furthermore, the decision curve analysis (DCA) highlighted the clinical net benefit achievable across various risk thresholds. These findings were reinforced by internal validation. CONCLUSIONS: The developed prediction model based on SUVmax and ADCmin showed practical value in guiding the optimization of prostate biopsy pattern. Lower SUVmax and Higher ADCmin values are associated with greater confidence in implementing mono-TB and safely avoiding SB, effectively balancing benefits and risks.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata , Humanos , Masculino , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Anciano , Persona de Mediana Edad , Medición de Riesgo , Isótopos de Galio , Biopsia Guiada por Imagen/métodos , Estudios Retrospectivos , Próstata/patología , Próstata/diagnóstico por imagen , Radioisótopos de Galio , Valor Predictivo de las Pruebas , Nomogramas , Biopsia/métodos
4.
Dalton Trans ; 53(18): 7946-7952, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38646723

RESUMEN

The absence of better biomarkers currently limits early diagnosis and treatment of triple-negative breast cancer (TNBC). Our previously published study reported that the cyclic-peptide SD01 exhibited specific binding to EphA2 (Ephrin type-A receptor 2) on TNBC. To develop a novel PET imaging agent, we prepared gallium-68 (68Ga) labeled-DOTA-SD01 and evaluated its specificity and effectiveness through micro PET/CT imaging in a TNBC-bearing mouse model. SD01 and a control linear peptide YSA were conjugated to DOTA and subsequently labeled with 68Ga, obtaining 68Ga-DOTA-SD01 and 68Ga-DOTA-YSA. Both showed high radiochemical purity, stability, good hydrophilicity, and high binding affinity to 4T1 cells. Micro PET/CT imaging showed high radioactivity accumulation in tumors; SUVmean (mean standardized uptake value) of tumors in the group of 68Ga-DOTA-SD01 was 3.34 ± 0.25 and 2.65 ± 0.32 in the group of 68Ga-DOTA-YSA; T/NT ratios (target to non-target, SUVmean ratios of tumor to muscle) were 3.12 ± 0.06 and 2.77 ± 0.11 at 30 min, respectively (p < 0.05). The biodistribution study showed that tumor uptake % ID per g (percentage of injected dose per gram of tissue) in the group of 68Ga-DOTA-SD01 was 2.73 ± 0.34, and 1.77 ± 0.38 in the group of 68Ga-DOTA-YSA; T/NT ratios (radioactivity of tumor to muscle) were 3.55 ± 0.12 and 3.05 ± 0.10 for both groups at 30 min, respectively (p < 0.05). All these suggest that 68Ga-DOTA-SD01 may act as a better novel PET imaging agent for EphA2 positive tumors, such as TNBC.


Asunto(s)
Radioisótopos de Galio , Péptidos Cíclicos , Receptor EphA2 , Neoplasias de la Mama Triple Negativas , Neoplasias de la Mama Triple Negativas/diagnóstico por imagen , Radioisótopos de Galio/química , Animales , Péptidos Cíclicos/química , Péptidos Cíclicos/farmacocinética , Receptor EphA2/metabolismo , Ratones , Femenino , Línea Celular Tumoral , Tomografía Computarizada por Tomografía de Emisión de Positrones , Distribución Tisular , Ratones Endogámicos BALB C , Compuestos Heterocíclicos con 1 Anillo/química , Humanos , Radiofármacos/química , Tomografía de Emisión de Positrones
5.
BMJ Open ; 14(4): e075680, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38643004

RESUMEN

INTRODUCTION: Accurate baseline clinical staging is critical to inform treatment decision-making for patients with gastric cancers. Peritoneal metastasis (PM) is the most common form of metastasis in gastric cancer and mainly diagnosed by diagnostic laparoscopy and peritoneal lavage evaluation. However, diagnostic laparoscopy is invasive and less cost-effective. It is urgent to develop a safe, fast and non-invasive functional imaging method to verify the peritoneal metastasis of gastric cancer. The aim of our study was to evaluate the proportion of patients in whom 68Ga-FAPI-04 positron emission tomography/CT (PET/CT) led to a change in treatment strategy and to assess the diagnostic accuracy of 68Ga-FAPI-04 PET/CT for the detection of occult peritoneal metastasis compared with laparoscopic exploration. METHODS AND ANALYSIS: In this single-centre, prospective diagnostic test accuracy study, a total of 48 patients with locally advanced gastric or gastro-oesophageal junction adenocarcinoma (cT4a-b, N0-3, M0, based on CT images) who are considering radical tumour surgery will be recruited. All participants will undergo 68Ga-FAPI-04 PET/CT before the initiation of laparoscopic exploration. The primary outcome is the proportion of patients with occult peritoneal metastatic lesions detected by 68Ga-FAPI-04 PET/CT, leading to a change in therapy strategy. The secondary outcomes include the diagnostic performance of 68Ga-FAPI-04 PET/CT for occult peritoneal metastasis, including sensitivity, specificity, accuracy, positive predictive value and negative predictive value. ETHICS AND DISSEMINATION: The study protocol was approved by the Ethics Committee of West China Hospital, Sichuan University (2022-1484). Study results will be presented at public and scientific conferences and in peer-reviewed journals. TRIAL REGISTRATION NUMBER: ChiCTR2300067591.


Asunto(s)
Laparoscopía , Neoplasias Peritoneales , Quinolinas , Neoplasias Gástricas , Humanos , Neoplasias Gástricas/diagnóstico por imagen , Radioisótopos de Galio , Estudios Prospectivos , Neoplasias Peritoneales/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones , Fluorodesoxiglucosa F18
6.
Hell J Nucl Med ; 27(1): 16-26, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38629815

RESUMEN

OBJECTIVE: Recently, gallium-68-prostate-specific membrane antigen-11 (68Ga-PSMA-11) positron emission tomography/computed tomography (PET/CT) has become a key imaging method in prostate carcinoma staging and biochemical progression, with varying sensitivities in different studies (from 40% to 80%). After four years of experience with 68Ga-PSMA-11 PET/CT, we found that it is possible to detect lesions with increased PSMA expression in patients with undetectable prostate specific antigen (PSA) levels after radical prostatectomy. The key questions we wanted to answer were as follows: if those lesions were malignant and could the early detection of those malignant lesions have a role in patient management? We aimed to identify and follow up PSMA-positive findings for a period of 4 years in patients with prostate cancer after radical prostatectomy and undetectable PSA values at the time of the examination. We also explored false-positive lesions in detail. SUBJECTS AND METHODS: The study included all patients who underwent radical prostatectomy and had undetectable PSA values <0.05ng/mL and who underwent 68Ga-PSMA-11 PET/CT between July 2019 and December 2019. We performed 220 studies and found 40 patients with these characteristics; these patients were included in this study. All of them were followed up until July 2023. Any finding with increased radiopharmaceutical accumulation above the background activity in the respective area was considered a false positive. Prostate-specific membrane antigen accumulation in established lesions was assessed semi-quantitatively by the maximum standardized uptake value (SUVmax) and qualitatively by the four-point visual scale proposed in the E-PSMA recommendations. RESULTS: We found 15/40 (37.5%) patients with PSMA-positive findings. These were predominantly bone changes without a corresponding CT abnormality or discrete cystic or osteoblastic lesions with above-background increased PSMA expression. The mean SUVmax of these non-specific lesions was 3.02 (SD 2.86). After 3.5-4 years of follow-up, biochemical progression was found in only two of the patients.The great sensitivity of the method nowadays is a powerful engine for the development of new therapeutic options. On the other side, the lower specificity due to false positive findings, if misinterpreted, might lead to switching to a higher stage, with the planned radical treatment replaced by palliative treatment. CONCLUSION: The presence of 68Ga-PSMA-11 PET/CT-positive findings in patients after radical prostatectomy and an undetectable PSA had a low predictive value for future progression. The interpretation of 68Ga-PSMA-11 PET/CT should always include a complex assessment of the clinical setting-the risk group, PSA value and degree of PSMA accumulation in the lesions. In these situations, further clarification of PSMA-positive findings is appropriate before deciding to change treatment.


Asunto(s)
Ácido Edético , Isótopos de Galio , Radioisótopos de Galio , Oligopéptidos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Antígeno Prostático Específico , Prostatectomía , Neoplasias de la Próstata , Humanos , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía , Neoplasias de la Próstata/metabolismo , Ácido Edético/análogos & derivados , Antígeno Prostático Específico/sangre , Anciano , Persona de Mediana Edad , Reacciones Falso Positivas , Pronóstico
7.
Bioorg Med Chem Lett ; 104: 129727, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38582132

RESUMEN

ß-galactosidase (ß-gal) has high activity in various malignancies, which is suitable for targeted positron emission tomography (PET) imaging. Meanwhile, ß-gal can successfully guide the formation of nanofibers, which enhances the intensity of imaging and extends the imaging time. Herein, we designed a ß-galactosidase-guided self-assembled PET imaging probe [68Ga]Nap-NOTA-1Gal. We envisage that ß-gal could recognize and cleave the target site, bringing about self-assembling to form nanofibers, thereby enhancing the PET imaging effect. The targeting specificity of [68Ga]Nap-NOTA-1Gal for detecting ß-gal activity was examined using the control probe [68Ga]Nap-NOTA-1. Micro-PET imaging showed that tumor regions of [68Ga]Nap-NOTA-1Gal were visible after injection. And the tumor uptake of [68Ga]Nap-NOTA-1Gal was higher than [68Ga]Nap-NOTA-1 at all-time points. Our results demonstrated that the [68Ga]Nap-NOTA-1Gal can be used for the purpose of a new promising PET probe for helping diagnose cancer with high levels of ß-gal activity.


Asunto(s)
Nanofibras , Neoplasias , Humanos , Radioisótopos de Galio , Tomografía de Emisión de Positrones/métodos , beta-Galactosidasa , Línea Celular Tumoral
8.
J Immunother Cancer ; 12(4)2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38580333

RESUMEN

BACKGROUND: The programmed cell death protein-1 (PD-1)/programmed death receptor ligand 1 (PD-L1) axis critically facilitates cancer cells' immune evasion. Antibody therapeutics targeting the PD-1/PD-L1 axis have shown remarkable efficacy in various tumors. Immuno-positron emission tomography (ImmunoPET) imaging of PD-L1 expression may help reshape solid tumors' immunotherapy landscape. METHODS: By immunizing an alpaca with recombinant human PD-L1, three clones of the variable domain of the heavy chain of heavy-chain only antibody (VHH) were screened, and RW102 with high binding affinity was selected for further studies. ABDRW102, a VHH derivative, was further engineered by fusing RW102 with the albumin binder ABD035. Based on the two targeting vectors, four PD-L1-specific tracers ([68Ga]Ga-NOTA-RW102, [68Ga]Ga-NOTA-ABDRW102, [64Cu]Cu-NOTA-ABDRW102, and [89Zr]Zr-DFO-ABDRW102) with different circulation times were developed. The diagnostic efficacies were thoroughly evaluated in preclinical solid tumor models, followed by a first-in-human translational investigation of [68Ga]Ga-NOTA-RW102 in patients with non-small cell lung cancer (NSCLC). RESULTS: While RW102 has a high binding affinity to PD-L1 with an excellent KD value of 15.29 pM, ABDRW102 simultaneously binds to human PD-L1 and human serum albumin with an excellent KD value of 3.71 pM and 3.38 pM, respectively. Radiotracers derived from RW102 and ABDRW102 have different in vivo circulation times. In preclinical studies, [68Ga]Ga-NOTA-RW102 immunoPET imaging allowed same-day annotation of differential PD-L1 expression with specificity, while [64Cu]Cu-NOTA-ABDRW102 and [89Zr]Zr-DFO-ABDRW102 enabled longitudinal visualization of PD-L1. More importantly, a pilot clinical trial shows the safety and diagnostic value of [68Ga]Ga-NOTA-RW102 immunoPET imaging in patients with NSCLCs and its potential to predict immune-related adverse effects following PD-L1-targeted immunotherapies. CONCLUSIONS: We developed and validated a series of PD-L1-targeted tracers. Initial preclinical and clinical evidence indicates that immunoPET imaging with [68Ga]Ga-NOTA-RW102 holds promise in visualizing differential PD-L1 expression, selecting patients for PD-L1-targeted immunotherapies, and monitoring immune-related adverse effects in patients receiving PD-L1-targeted treatments. TRIAL REGISTRATION NUMBER: NCT06165874.


Asunto(s)
Antígeno B7-H1 , Carcinoma de Pulmón de Células no Pequeñas , Compuestos Heterocíclicos con 1 Anillo , Neoplasias Pulmonares , Anticuerpos de Dominio Único , Humanos , Antígeno B7-H1/efectos de los fármacos , Antígeno B7-H1/metabolismo , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/tratamiento farmacológico , Carcinoma de Pulmón de Células no Pequeñas/patología , Línea Celular Tumoral , Radioisótopos de Galio , Neoplasias Pulmonares/tratamiento farmacológico , Neoplasias Pulmonares/patología , Receptor de Muerte Celular Programada 1 , Anticuerpos de Dominio Único/farmacología , Anticuerpos de Dominio Único/uso terapéutico
9.
Nucl Med Rev Cent East Eur ; 27(0): 6-12, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38680016

RESUMEN

BACKGROUND: As in disease recurrence, providing clinicians with the exact extent of the disease at the time of initial diagnosis is key in the management and individual treatment of prostate cancer (PC) patients. Intending to examine the usefulness of gallium- 68 PSMA-11 positron emission tomography/computed tomography ([68Ga]Ga-PSMA-11 PET/CT) and to determine if there is a correlation between prostate-specific antigen (PSA) serum values, WHO/ISUP (World Health Organization/International Society of Urological Pathology's) grade group of the tumor and SUVmax (maximized standardized uptake value) values we retrospectively analyzed PET/CT studies performed for initial staging of the disease. PATIENTS AND METHODS: We retrospectively evaluated 34 studies of patients who underwent [68Ga]Ga-PSMA-11 PET/CT as part of the initial staging of prostate cancer. All patients had prostate cancer confirmed by histological assessment after biopsy and had Gleason score and PSA serum values obtained. The mean PSA value was 33.8 ± 40.9 nmol/L (range 2.2-232). RESULTS: Nineteen patients had extended disease (55.9%). The mean SUVmax in prostate lesions was 19.5 ± 12.6. The mean value of SUVmax of PET studies in the high-risk group was significantly higher than those of low risk (23.5 ± 13.2 and 10.6 ± 5.4, p < 0.05). A positive correlation was observed between the ISUP group and SUVmax value of prostate lesions (Pearson's r = 0.557, p < 0.01). A positive correlation was also found in the comparison between PSA values and SUVmax (Pearson's r = 0.34, p < 0.05). CONCLUSIONS: In our study, [68Ga]Ga-PSMA-11 PET/CT scans detected the extended disease in more than half of the patients. Locating disease beyond the prostate gland allowed better informed clinical decisions and modified treatment. A positive correlation was found between intraprostatic SUVmax values and the ISUP group of prostate cancer. High-risk patients had SUVmax values that were significantly higher than those of low-risk patients. The correlation between the Gleason score and SUVmax value can be explained by the increased intensity of PSMA expression as the tumor grade increases.


Asunto(s)
Ácido Edético , Isótopos de Galio , Radioisótopos de Galio , Estadificación de Neoplasias , Oligopéptidos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata , Humanos , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Ácido Edético/análogos & derivados , Anciano , Persona de Mediana Edad , Estudios Retrospectivos , Anciano de 80 o más Años , Antígeno Prostático Específico/sangre
10.
Surgery ; 175(1): 228-233, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38563428

RESUMEN

BACKGROUND: Fluorodeoxyglucose uptake on positron emission tomography imaging has been shown to be an independent risk factor for malignancy in thyroid nodules. More recently, a new positron emission tomography radiotracer-Gallium-68 DOTATATE-has gained popularity as a sensitive method to detect neuroendocrine tumors. With greater availability of this imaging, incidental Gallium-68 DOTATATE uptake in the thyroid gland has increased. It is unclear whether current guideline-directed management of thyroid nodules remains appropriate in those that are Gallium-68 DOTATATE avid. METHODS: We retrospectively reviewed Gallium-68 DOTATATE positron emission tomography scans performed at our institution from 2012 to 2022. Patients with incidental focal Gallium-68 DOTATATE uptake in the thyroid gland were included. Fine needle aspiration biopsies were characterized via the Bethesda System for Reporting Thyroid Cytopathology. Bethesda III/IV nodules underwent molecular testing (ThyroSeq v3), and malignancy risk ≥50% was considered positive. RESULTS: In total, 1,176 Gallium-68 DOTATATE PET scans were reviewed across 837 unique patients. Fifty-three (6.3%) patients demonstrated focal Gallium-68 DOTATATE thyroid uptake. Nine patients were imaged for known medullary thyroid cancer. Forty-four patients had incidental radiotracer uptake in the thyroid and were included in our study. Patients included in the study were predominantly female sex (75%), with an average age of 62.9 ± 13.9 years and a maximum standardized uptake value in the thyroid of 7.3 ± 5.3. Frequent indications for imaging included neuroendocrine tumors of the small bowel (n = 17), lung (n = 8), and pancreas (n = 7). Thirty-three patients underwent subsequent thyroid ultrasound. Sonographic findings warranted biopsy in 24 patients, of which 3 were lost to follow-up. Cytopathology and molecular testing results are as follows: 12 Bethesda II (57.1%), 6 Bethesda III/ThyroSeq-negative (28.6%), 1 Bethesda III/ThyroSeq-positive (4.8%), 2 Bethesda V/VI (9.5%). Four nodules were resected, revealing 2 papillary thyroid cancers, 1 neoplasm with papillary-like nuclear features, and 1 follicular adenoma. There was no difference in maximum standardized uptake value between benign and malignant nodules (7.0 ± 4.6 vs 13.1 ± 5.7, P = .106). Overall, the malignancy rate among patients with sonography and appropriate follow-up was 6.7% (2/30). Among patients with cyto- or histopathology, the malignancy rate was 9.5% (2/21). There were no incidental cases of medullary thyroid cancer. CONCLUSION: The malignancy rate among thyroid nodules with incidental Gallium-68 DOTATATE uptake is comparable to rates reported among thyroid nodules in the general population. Guideline-directed management of thyroid nodules remains appropriate in those with incidental Gallium-68 DOTATATE uptake.


Asunto(s)
Carcinoma Neuroendocrino , Tomografía de Emisión de Positrones , Cintigrafía , Neoplasias de la Tiroides , Nódulo Tiroideo , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Nódulo Tiroideo/patología , Radioisótopos de Galio , Estudios Retrospectivos , Neoplasias de la Tiroides/diagnóstico , Biopsia con Aguja Fina , Carcinoma Neuroendocrino/diagnóstico por imagen , Carcinoma Neuroendocrino/terapia
11.
Mol Pharm ; 21(5): 2375-2382, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38573777

RESUMEN

We investigated the importance of the carboxy group density in bone affinity during the development of peptide-based bone-seeking radiopharmaceuticals and carriers. Oligo-γ-carboxy glutamic acid peptides [(Gla)n] with higher carboxy group density than oligo-glutamic acid peptides [(Glu)n] and oligo-aspartic acid peptides [(Asp)n] were chosen. Using the radiogallium chelator N,N'-bis-[2-hydroxy-5-(carboxyethyl)benzyl]ethylenediamine-N,N'-diacetic acid (HBED-CC), we synthesized [67Ga]Ga-HBED-CC-(Gla)n (n = 1, 2, 5, 8, 11, or 14) with high yields. Hydroxyapatite-binding assays, biodistribution, and SPECT imaging showed higher affinity and bone accumulation for [67Ga]Ga-HBED-CC-(Gla)n compared to [67Ga]Ga-HBED-CC-(Glu)n. Notably, [67Ga]Ga-HBED-CC-(Gla)8 and [67Ga]Ga-HBED-CC-(Gla)11 exhibited superior bone accumulation and rapid blood clearance. SPECT/CT imaging with [67Ga]Ga-HBED-CC-(Gla)8 exclusively visualized the bone tissue. These findings support the potential use of [67Ga]Ga-HBED-CC-(Gla)n as excellent bone-imaging PET probes, suggesting (Gla)n peptides are superior bone-seeking carriers.


Asunto(s)
Huesos , Radioisótopos de Galio , Radiofármacos , Tomografía Computarizada de Emisión de Fotón Único , Animales , Radioisótopos de Galio/farmacocinética , Radioisótopos de Galio/química , Radiofármacos/farmacocinética , Ratones , Distribución Tisular , Tomografía Computarizada de Emisión de Fotón Único/métodos , Huesos/diagnóstico por imagen , Huesos/metabolismo , Péptidos/química , Durapatita/química , Masculino , Ácido Glutámico/metabolismo , Femenino
12.
Mol Pharm ; 21(5): 2415-2424, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38606663

RESUMEN

Chemokines and chemokine receptors are indispensable to play a key role in the development of malignant tumors. As one of the most widely expressed chemokine receptors, chemokine (C-X-C motif) receptor 4 (CXCR4) has been a popular research focus. In most tumors, CXCR4 expression is significantly upregulated. Moreover, integrated nuclide diagnosis and therapy targeting CXCR4 show great potential. [68Ga]Ga-pentixafor, a radioligand targeting CXCR4, exhibits a strong affinity for CXCR4 both in vivo and in vitro. However, [177Lu]Lu-pentixather, the therapeutic companion of [68Ga]Ga-pentixafor, requires significant refinement to mitigate its pronounced hepatic biodistribution. The objective of this study was to synthesize theranostic molecular tracers with superior CXCR4 targeting functions. The Daudi cell line, which highly expressed CXCR4, and the MM.1S cell line, which weakly expressed CXCR4, were used in this study. Based on the pharmacophore cyclo (-d-Tyr-n-me-d-Orn-l-Arg-L-2-NAL-Gly-) (CPCR4) of pentixafor, six tracers were synthesized: [124I]I-1 ([124I]I-CPCR4), [99mTc]Tc-2 ([99mTc]Tc-HYNIC-CPCR4), [124I]I-3 ([124I]I-pentixafor), [18F]AlF-4 ([18F]AlF-NETA-CPCR4), [99mTc]Tc-5 ([99mTc]Tc-MAG3-CPCR4) and [124I]I-6 ([124I]I-pentixafor-Ga) and their radiochemical purities were all higher than 95%. After positron emission tomography (PET)/single-photon emission computed tomography (SPECT) imaging, the [124I]I-6 group exhibited the best target-nontarget ratio. At the same time, comparing the [68Ga]Ga-pentixafor group with the [124I]I-6 group, we found that the [124I]I-6 group had a better target-nontarget ratio and lower uptake in nontarget organs. Therefore, compound 6 was selected for therapeutic radionuclide (131I) labeling, and the tumor-bearing animal models were treated with [131I]I-6. The volume of the tumor site was significantly reduced in the treatment group compared with the control group, and no significant side effects were found. [124I]I-6 and [131I]I-6 showed excellent affinity for targeting CXCR4, and they showed great potential for the integrated diagnosis and treatment of tumors with high CXCR4 expression.


Asunto(s)
Complejos de Coordinación , Receptores CXCR4 , Receptores CXCR4/metabolismo , Receptores CXCR4/genética , Animales , Humanos , Ratones , Línea Celular Tumoral , Distribución Tisular , Radiofármacos/farmacocinética , Radiofármacos/farmacología , Radiofármacos/química , Péptidos Cíclicos/química , Péptidos Cíclicos/farmacología , Sondas Moleculares/química , Sondas Moleculares/farmacocinética , Radioisótopos de Galio , Ratones Desnudos , Nanomedicina Teranóstica/métodos , Femenino
13.
Clin Nucl Med ; 49(6): 587-588, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38557426

RESUMEN

ABSTRACT: Prostate carcinoma (PC) is the second most common malignant tumor in males globally. The metastatic spread of PC usually involves the pelvic and abdominal lymph nodes and the skeletal system. Cutaneous metastases are exceedingly uncommon and typically manifest themselves late in the disease course, considered as ominous sign with limited treatment options and a poor prognosis. We describe a patient wherein 68 Ga-PSMA-11 PET/CT detected multiple uncommon metastatic sites in the cutaneous region of the scrotum, penis, and thigh, as well as in the subcutaneous region of anterior abdominal wall, and in bilateral adrenal glands. These findings served as a theranostic tool for selecting 177 Lu-PSMA-617 treatment for these extremely rare metastatic sites.


Asunto(s)
Neoplasias de las Glándulas Suprarrenales , Isótopos de Galio , Radioisótopos de Galio , Lutecio , Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata , Neoplasias Cutáneas , Humanos , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Neoplasias de las Glándulas Suprarrenales/diagnóstico por imagen , Neoplasias de las Glándulas Suprarrenales/secundario , Neoplasias Cutáneas/diagnóstico por imagen , Neoplasias Cutáneas/patología , Compuestos Heterocíclicos con 1 Anillo/uso terapéutico , Ácido Edético/análogos & derivados , Progresión de la Enfermedad , Radioisótopos/uso terapéutico , Dipéptidos/uso terapéutico , Anciano , Oligopéptidos , Tejido Subcutáneo/diagnóstico por imagen , Tejido Subcutáneo/patología , Medicina de Precisión
14.
Clin Nucl Med ; 49(6): 564-566, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38557828

RESUMEN

ABSTRACT: We report findings from 68 Ga-DOTATATE and 68 Ga-FAPI PET/CT in a 43-year-old woman with neuroendocrine neoplasms. DOTATATE and FAPI uptake differed in different lesions. These results suggest a potential value for dual-tracer imaging in the evaluation of neuroendocrine neoplasms that have different grades.


Asunto(s)
Tumores Neuroendocrinos , Compuestos Organometálicos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Femenino , Adulto , Tumores Neuroendocrinos/diagnóstico por imagen , Tumores Neuroendocrinos/patología , Clasificación del Tumor , Radioisótopos de Galio
15.
Clin Nucl Med ; 49(6): e278-e280, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38598550

RESUMEN

ABSTRACT: A 72-year-old man revealed typical findings of cardiac sarcoidosis on cardiovascular MRI. However, 18 F-FDG PET showed no hypermetabolism. Therefore, immunosuppression was not initiated. After 2 years, ventricular arrhythmias and heart failure worsened. 68 Ga-fibroblast activation protein inhibitor PET was initiated to evaluate potential adverse remodeling due to progressive myocardial fibrosis. A second 18 F-FDG PET still revealed no hypermetabolism, and the patient received an implanted cardioverter defibrillator after electrophysiological risk stratification. We present a case of intense fibroblast activation despite a missing 18 F-FDG uptake (mismatch).


Asunto(s)
Biomarcadores , Cardiomiopatías , Radioisótopos de Galio , Sarcoidosis , Humanos , Sarcoidosis/diagnóstico por imagen , Masculino , Anciano , Cardiomiopatías/diagnóstico por imagen , Biomarcadores/metabolismo , Tomografía de Emisión de Positrones , Transporte Biológico , Fluorodesoxiglucosa F18
16.
Clin Nucl Med ; 49(6): 592-593, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38630995

RESUMEN

ABSTRACT: An 83-year-old woman with newly diagnosed multiple myeloma (MM) was enrolled in our 68 Ga-pentixather and 68 Ga-pentixafor PET/CT trial for evaluation of tumor burden. 68 Ga-pentixather PET/CT detected more focal bone lesions, and the uptake levels of focal bone lesions on 68 Ga-pentixather PET/CT were higher than those on 68 Ga-pentixafor PET/CT. This suggests that 68 Ga-pentixather PET/CT may be an alternative imaging modality and more sensitive in detecting MM lesions than 68 Ga-pentixafor PET/CT.


Asunto(s)
Mieloma Múltiple , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Mieloma Múltiple/diagnóstico por imagen , Femenino , Anciano de 80 o más Años , Radioisótopos de Galio , Péptidos Cíclicos , Complejos de Coordinación
17.
J Nucl Med ; 65(5): 761-767, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38514083

RESUMEN

The membrane protein carbonic anhydrase IX (CAIX) is highly expressed in many hypoxic or von Hippel-Lindau tumor suppressor-mutated tumor types. Its restricted expression in healthy tissues makes CAIX an attractive diagnostic and therapeutic target. DPI-4452 is a CAIX-targeting cyclic peptide with a DOTA cage, allowing radionuclide chelation for theranostic purposes. Here, we report CAIX expression in multiple tumor types and provide in vitro and in vivo evaluations of 68Ga-labeled DPI-4452 ([68Ga]Ga-DPI-4452) and 177Lu-labeled DPI-4452 ([177Lu]Lu-DPI-4452). Methods: CAIX expression was assessed by immunohistochemistry with a panel of tumor and healthy tissues. The molecular interactions of complexed and uncomplexed DPI-4452 with CAIX were assessed by surface plasmon resonance and cell-binding assays. In vivo characterization of radiolabeled and nonradiolabeled DPI-4452 was performed in HT-29 colorectal cancer (CRC) and SK-RC-52 clear cell renal cell carcinoma (ccRCC) human xenograft mouse models and in healthy beagle dogs. Results: Overexpression of CAIX was shown in several tumor types, including ccRCC, CRC, and pancreatic ductal adenocarcinoma. DPI-4452 specifically and selectively bound CAIX with subnanomolar affinity. In cell-binding assays, DPI-4452 displayed comparably high affinities for human and canine CAIX but a much lower affinity for murine CAIX, demonstrating that the dog is a relevant species for biodistribution studies. DPI-4452 was rapidly eliminated from the systemic circulation of beagle dogs. The highest uptake of [68Ga]Ga-DPI-4452 and [177Lu]Lu-DPI-4452 was observed in the small intestine and stomach, 2 organs known to express CAIX. Uptake in other organs (e.g., kidneys) was remarkably low. In HT-29 and SK-RC-52 xenograft mouse models, both [68Ga]Ga-DPI-4452 and [177Lu]Lu-DPI-4452 showed tumor-selective uptake; in addition, [177Lu]Lu-DPI-4452 significantly reduced tumor growth. These results demonstrated the theranostic potential of DPI-4452. Conclusion: DPI-4452 selectively targets CAIX. [68Ga]Ga-DPI-4452 and [177Lu]Lu-DPI-4452 localized to tumors and were well tolerated in mice. [177Lu]Lu-DPI-4452 demonstrated strong tumor growth inhibition in 2 xenograft mouse models. Thus, the 2 agents potentially provide a theranostic approach for selecting and treating patients with CAIX-expressing tumors such as ccRCC, CRC, and pancreatic ductal adenocarcinoma.


Asunto(s)
Anhidrasa Carbónica IX , Radioisótopos de Galio , Lutecio , Radioisótopos , Anhidrasa Carbónica IX/metabolismo , Humanos , Animales , Ratones , Radioisótopos/uso terapéutico , Línea Celular Tumoral , Distribución Tisular , Ligandos , Antígenos de Neoplasias/metabolismo , Nanomedicina Teranóstica , Medicina de Precisión , Femenino , Perros
18.
Clin Nucl Med ; 49(6): 572-573, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38466027

RESUMEN

ABSTRACT: A 67-year-old woman was enrolled in our 68 Ga-FAPI PET/CT tumor clinical trial due to her lung adenocarcinoma. The PET/CT scan additionally revealed increased uptake of FAPI in the tongue. Combined with the patient's medical history and the contrast-enhanced CT of the maxillofacial region, it was suspected to be a hemangioma. Subsequently, the patient underwent surgery and was diagnosed with capillary hemangioma of the left side of her tongue.


Asunto(s)
Hemangioma Capilar , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Femenino , Anciano , Hemangioma Capilar/diagnóstico por imagen , Hemangioma Capilar/metabolismo , Radioisótopos de Galio , Transporte Biológico
19.
Nucl Med Biol ; 130-131: 108892, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38447298

RESUMEN

INTRODUCTION: Increased demand for NetSpot and Illuccix as requirement to receive the respective Lutathera and Pluvicto radiotherapies, and monitor subsequent response to treatment, have reinforced the need to develop alternative ways of producing gallium-68 (68Ga). Building on our efforts to produce 68Ga in a liquid target on a GE PETtrace, the goal of this work is to modify the current GE Gallium Chloride cassette using the FASTLab 2 synthesis module to produce [68Ga]GaCl3 equivalent to a 1.85 GBq generator and demonstrate compatibility with FDA-approved kits for production of 68Ga-labeled radiopharmaceuticals. METHODS: 68Ga was produced in a liquid target via the 68Zn(p,n)68Ga reaction. 68Ga was loaded onto various sizes of ZR resins (ZR Load, 0.3 mL, 1 mL, or 2 mL). The loading efficiency was determined using a dose calibrator. After washing with HNO3, 1.75 M HCl was used to elute the ZR Load resin through various sizes of a second ZR resin (ZR CG, 0 mL, 2 mL, 4 mL). Using 0.5 mL fractions, the elution profile was determined. Compatibility of the [68Ga]GaCl3 with NetSpot and Illuccix kits was investigated. Radiochemical purity (RCP) and 4 h stability were determined using radioTLC and radioHPLC. Using a modified [68Ga]GaCl3 cassette and new FASTLab program, 6 validation preparations were conducted using NetSpot and Illuccix kits for which RCP, stability, sterility and suitability were determined. Dual irradiation of 2 liquid targets was also performed, which was used to simultaneously prepare 1 NetSpot and 2 Illuccix kits by diluting the required activity with 0.1 M HCl. RESULTS: The commercially available GE Cassette gave low RCP using commercial FDA kits. To optimize this, the loading efficiency onto ZR Load and the ratio of ZR resin used to load the initial activity and subsequent elution were explored. When using a 2:4 ratio of ZR Load to ZR CG, 97.89 % RCP was observed when a 3.8 mL [68Ga]GaCl3 solution was used. For Dotatate validation, 0.55 mL of buffer was added to 4.2 mL of [68Ga]GaCl3 which gave 1.35 GBq of formulated product. For Illuccix validation, [68Ga]GaCl3 was added to 2.5 mL of buffer which gave 1.52 GBq of [68Ga]Ga-PSMA-11. Formulated products passed package insert quality control (QC) requirements. When dual target irradiations were performed, 2.84 GBq was delivered to an external vial and used to label 1 NetSpot and 2 Illuccix kits simultaneously, and each kit also met or exceeded established QC criteria. CONCLUSION: Methods are reported for using cyclotron-produced 68Ga from a liquid target in conjunction with FDA-approved NetSpot and Illucix kits. By employing a 2 mL ZR Load resin with a 4 mL ZR CG resin, adequate resolution between residual 68Zn and desired 68Ga was achieved. By modifying the FASTLab procedure to retain the final 2.5 mL of eluate from the ZR CG resin, [68Ga]GaCl3 equivalent to a new 1.85 GBq generator was obtained. This was suitable for labeling NetSpot and Illucix kits, resulting in high incorporation of 68Ga (RCP >95 %), which has not previously been demonstrated. Delivering [68Ga]GaCl3 into an external vial and diluting with 0.1 M HCl makes it possible to prepare multiple kits simultaneously. These new procedures should facilitate use of cyclotron-produced [68Ga]GaCl3 for clinical production going.


Asunto(s)
Radioisótopos de Galio , Compuestos Organometálicos , Radiofármacos , Radiofármacos/metabolismo , Radioisótopos de Galio/metabolismo , Ciclotrones
20.
J Med Chem ; 67(6): 4793-4803, 2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38450559

RESUMEN

Bone metastasis in cancer patients is a major disease advancement for various types of cancer. Previously, [68Ga]Ga-HBED-CC-bisphosphonate ([68Ga]Ga-P15-041) showed excellent bone uptake and efficient detection of bone metastasis in patients. To accommodate different α- or ß--emitting metals for radionuclide therapy, a novel DOTA-HBED-CC-bisphosphonate (P15-073, 1) was prepared and the corresponding [68Ga]Ga-1 and [177Lu]Lu-1 were successfully synthesized in high yields and purity. Gallium-68 conjugation to HBED-CC at room temperature and lutetium-177 conjugation to DOTA at 95 °C were verified in model compounds through secondary mass confirmation. These bisphosphonates, [68Ga]Ga-1 and [177Lu]Lu-1, displayed high binding affinity to hydroxyapatite in vitro. After an iv injection, it showed excellent uptake in the spine of normal mice, and micro-PET/CT imaging of nude mice model of bone metastasis showed high bone uptake in tumor tissue. The results indicated that [68Ga]Ga/[177Lu]Lu-1 holds promise as a theranostic radioligand agent for managing cancer bone metastases.


Asunto(s)
Neoplasias Óseas , Ácido Edético/análogos & derivados , Radioisótopos de Galio , Compuestos Heterocíclicos con 1 Anillo , Humanos , Ratones , Animales , Tomografía Computarizada por Tomografía de Emisión de Positrones , Difosfonatos/uso terapéutico , Medicina de Precisión , Ratones Desnudos , Neoplasias Óseas/diagnóstico por imagen , Neoplasias Óseas/tratamiento farmacológico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...