Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63.383
Filtrar
1.
BMC Neurol ; 24(1): 144, 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38724916

RESUMEN

BACKGROUND: Restoring shoulder function is critical for upper-extremity rehabilitation following a stroke. The complex musculoskeletal anatomy of the shoulder presents a challenge for safely assisting elevation movements through robotic interventions. The level of shoulder elevation assistance in rehabilitation is often based on clinical judgment. There is no standardized method for deriving an optimal level of assistance, underscoring the importance of addressing abnormal movements during shoulder elevation, such as abnormal synergies and compensatory actions. This study aimed to investigate the effectiveness and safety of a newly developed shoulder elevation exoskeleton robot by applying a novel optimization technique derived from the muscle synergy index. METHODS: Twelve chronic stroke participants underwent an intervention consisting of 100 robot-assisted shoulder elevation exercises (10 × 10 times, approximately 40 min) for 10 days (4-5 times/week). The optimal robot assist rate was derived by detecting the change points using the co-contraction index, calculated from electromyogram (EMG) data obtained from the anterior deltoid and biceps brachii muscles during shoulder elevation at the initial evaluation. The primary outcomes were the Fugl-Meyer assessment-upper extremity (FMA-UE) shoulder/elbow/forearm score, kinematic outcomes (maximum angle of voluntary shoulder flexion and elbow flexion ratio during shoulder elevation), and shoulder pain outcomes (pain-free passive shoulder flexion range of motion [ROM] and visual analogue scale for pain severity during shoulder flexion). The effectiveness and safety of robotic therapy were examined using the Wilcoxon signed-rank sum test. RESULTS: All 12 patients completed the procedure without any adverse events. Two participants were excluded from the analysis because the EMG of the biceps brachii was not obtained. Ten participants (five men and five women; mean age: 57.0 [5.5] years; mean FMA-UE total score: 18.7 [10.5] points) showed significant improvement in the FMA-UE shoulder/elbow/forearm score, kinematic outcomes, and pain-free passive shoulder flexion ROM (P < 0.05). The shoulder pain outcomes remained unchanged or improved in all patients. CONCLUSIONS: The study presents a method for deriving the optimal robotic assist rate. Rehabilitation using a shoulder robot based on this derived optimal assist rate showed the possibility of safely improving the upper-extremity function in patients with severe stroke in the chronic phase.


Asunto(s)
Electromiografía , Dispositivo Exoesqueleto , Estudios de Factibilidad , Músculo Esquelético , Hombro , Rehabilitación de Accidente Cerebrovascular , Humanos , Masculino , Femenino , Rehabilitación de Accidente Cerebrovascular/métodos , Persona de Mediana Edad , Anciano , Hombro/fisiopatología , Hombro/fisiología , Electromiografía/métodos , Músculo Esquelético/fisiopatología , Músculo Esquelético/fisiología , Rango del Movimiento Articular/fisiología , Terapia por Ejercicio/métodos , Accidente Cerebrovascular/fisiopatología , Robótica/métodos , Fenómenos Biomecánicos/fisiología , Adulto
2.
J Orthop Surg Res ; 19(1): 288, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38725067

RESUMEN

BACKGROUND: The Enhanced Recovery After Surgery (ERAS) Society recommends that after total knee arthroplasty (TKA), patients should be mobilized early. However, there is no consensus on how early physical therapy should be commenced. We aim to investigate whether ultra-early physical therapy (< 12 h postoperatively) leads to better outcomes. METHODS: This is a retrospective cohort study of 569 patients who underwent primary TKA from August 2017 to December 2019 at our institution. We compared patients who had undergone physical therapy either within 24 h or 24-48 h after TKA. Further subgroup analysis was performed on the < 24 h group, comparing those who had undergone PT within 12 h and within 12-24 h. The outcomes analyzed include the Oxford Knee Scoring System score, Knee Society Scores, range of motion (ROM), length of stay (LOS) and ambulatory distance on discharge. A student's t test, chi-squared test or Fisher's exact test was used where appropriate, to determine statistical significance of our findings. RESULTS: LOS in the < 24 h group was shorter compared to the 24-48 h group (4.87 vs. 5.34 days, p = 0.002). Subgroup analysis showed that LOS was shorter in the ultra-early PT (< 12 h) group compared to the early PT (12-24 h) group (4.75 vs. 4.96 days, p = 0.009). At 3 months postoperatively, there was no significant difference in ROM, ambulatory distance or functional scores between the < 24 h group and 24-48 h group, or on subgroup analysis of the < 24 h group. CONCLUSION: Patients who underwent physical therapy within 24 h had a shorter length of stay compared to the 24-48 h group. On subgroup analysis, ultra-early (< 12 h) physical therapy correlated with a shorter length of stay compared to the 12-24 h group (4.75 vs. 4.96 days, p = 0.009) - however, the difference is small and unlikely to be clinically significant. Ultra-early (< 12 h) physical therapy does not confer additional benefit in terms of functional scores, ROM or ambulatory distance. These findings reinforce the importance of early physical therapy after TKA in facilitating earlier patient discharge.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Tiempo de Internación , Modalidades de Fisioterapia , Recuperación de la Función , Humanos , Artroplastia de Reemplazo de Rodilla/rehabilitación , Artroplastia de Reemplazo de Rodilla/métodos , Estudios Retrospectivos , Femenino , Masculino , Anciano , Persona de Mediana Edad , Resultado del Tratamiento , Factores de Tiempo , Rango del Movimiento Articular , Estudios de Cohortes , Anciano de 80 o más Años
3.
PLoS One ; 19(5): e0303365, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38728246

RESUMEN

INTRODUCTION/BACKGROUND: Neck pain is a burdensome condition associated with pain, disability, and economic cost. Neck pain has been associated with observable changes in neuromuscular function and biomechanics. Prior research shows impairments in kinematic control, including reduced mobility, velocity, and smoothness of cervical motion. However, the strength of association between these impairments and patient-reported pain and disability is unclear rendering development of novel and relevant rehabilitation strategies difficult. The aim of this systematic review is to synthesize existing evidence on the strength of association between clinical biomechanical metrics of neck function (ROM, strength, acceleration, accuracy, smoothness, etc.) and patient-reported neck pain and disability. METHODS/ANALYSIS: This protocol follows Cochrane guidelines and adheres to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Protocols (PRISMA-P). MEDLINE, EMBASE, CINAHL, SPORTDiscus, Web of Science and Scopus will be searched, along with the gray literature, up to 20 November 2023, using terms and keywords derived from initial scoping searches. Observational studies, including cohorts and cross-sectional studies, that explore associations between clinical biomechanics of the neck and patient-reported outcomes of neck pain or disability will be included. Two reviewers will independently perform study selection, data extraction, and risk of bias assessment (National Institute of Health tool). Data will be synthesized using either a random effects meta-analytic approach or qualitatively using a modified Grading of Recommendations, Assessment, Development and Evaluation (GRADE) approach, dependent on the homogeneity of data available. DISCUSSION AND RELEVANCE: This review addresses a gap in the literature by systematically synthesizing findings on the relationship between neck function impairments and patient-reported outcomes. It will identify priorities for neck pain rehabilitation and gaps in current knowledge. DISSEMINATION: The results of this review will be disseminated through a peer-reviewed publication, conference presentation, and lay language summaries posted on an open-access website. TRIAL REGISTRATION: PROSPERO Registration number: CRD42023417317. https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42023417317.


Asunto(s)
Vértebras Cervicales , Metaanálisis como Asunto , Dolor de Cuello , Revisiones Sistemáticas como Asunto , Humanos , Dolor de Cuello/fisiopatología , Vértebras Cervicales/fisiopatología , Fenómenos Biomecánicos , Rango del Movimiento Articular
4.
PLoS One ; 19(5): e0303066, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38728251

RESUMEN

INTRODUCTION: People with chronic neck pain (CNP) commonly exhibit a range of physical impairments including cervical proprioceptive deficits. Assessing proprioception using a head mounted laser to assess joint position error (JPE) is a reliable and valid measure. However, the responsiveness of this measure has not been assessed. OBJECTIVE: To assess the responsiveness of the measure of cervical JPE after a 4-week home-based neck proprioceptive training intervention in people with CNP. DESIGN: An observational study to assess the responsiveness of the measure of cervical JPE. METHODS: The JPE test was assessed in people with CNP before and after 4 weeks of neck proprioception training. JPE was assessed as participants performed neck joint position sense tests for flexion, extension, right rotation, and left rotation in sitting and standing which were performed in a random order. Both the absolute and constant JPE were assessed. The intervention consisted of neck repositioning exercises as well as movement sense exercises. Cohen's d effect size was used to assess the internal responsiveness of the JPE test. The Pearson's correlation was used to assess the change of scores of the laser pointer and measures from inertial measurement units (IMUs) (external responsiveness). RESULTS: After 4 weeks of proprioception training, JPE assessed in sitting reduced from 2.69◦-3.57◦ to 1.88◦-1.98◦ for flexion, extension, and right rotation with large effect sizes (Cohen's d range: 1.25-2.00). For left rotation, JPE reduced from 3.23◦ to 1.9◦, and the effect size was close to being large (Cohen's d: 0.79). When assessed in standing, JPE reduced from 3.49◦-4.52◦ to 1.5◦-2.33◦ with large effect sizes (Cohen's d range: 0.89-1.25) for flexion, extension, right rotation, and left rotation. Large effect sizes were not observed for the constant JPE when assessed in either sitting or standing. The assessment of the external responsiveness revealed weak correlations between the change of scores obtained from the laser pointer and the IMUs for all movements, apart from the constant JPE in sitting for left rotation, which showed a strong correlation (r = 0.7). CONCLUSION: The results of this study showed that the measure of the JPE has sufficient internal responsiveness, however, the external responsiveness was inadequate. Further research is advised.


Asunto(s)
Dolor de Cuello , Propiocepción , Humanos , Propiocepción/fisiología , Femenino , Masculino , Adulto , Dolor de Cuello/fisiopatología , Dolor de Cuello/terapia , Persona de Mediana Edad , Terapia por Ejercicio/métodos , Rango del Movimiento Articular/fisiología , Cuello/fisiología , Cuello/fisiopatología , Vértebras Cervicales/fisiopatología
5.
Int J Med Robot ; 20(3): e2635, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38733580

RESUMEN

BACKGROUND: Rotational alignment in total knee arthroplasty (TKA) is a crucial technical point that needs attention. We conducted a retrospective study to investigate whether a new robot-assisted TKA (RA-TKA) could improve the accuracy of rotational alignment and whether rotational alignment affects postoperative pain and functional evaluation of the knee. METHODS: A total of 136 consecutive patients who underwent TKA were included in this study. Half of the patients underwent RA-TKA and the other half underwent conventional TKA (CON-TKA) by the same group of surgeons. Collect the relevant parameters. RESULTS: The postoperative femoral rotation angle (FRA) was -0.72 ± 2.59° in the robot-assisted group and 1.13 ± 2.73° in the conventional group, and were statistically significantly different (p < 0.001). CONCLUSION: This study provides preliminary evidence that the RA-TKA provides more precise control of FRA than CON-TKA, and verifies that tibial rotation angle and combined rotation angle affect postoperative knee pain and functional evaluation.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Fémur , Procedimientos Quirúrgicos Robotizados , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Estudios Retrospectivos , Femenino , Masculino , Anciano , Persona de Mediana Edad , Rotación , Fémur/cirugía , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiopatología , Rango del Movimiento Articular , Dolor Postoperatorio/prevención & control , Dolor Postoperatorio/etiología , Resultado del Tratamiento
6.
J Pediatr Health Care ; 38(3): e1-e4, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38697700

RESUMEN

We describe the case of a 6-year-old female who presented with tender nodules and fixed flexion of her thumbs, diagnosed as bilateral pediatric trigger thumb. Though present since infancy, her condition was not diagnosed in prior clinical visits. Pediatric trigger digit is a clinical diagnosis, often missed if the digit's range of motion is not assessed routinely. Given the duration, pain, and severity of her condition, conservative management was deferred, and she was referred for surgery. An approach to clinical management is discussed. Ultimately, further study is required to develop structured management guidelines for pediatric trigger digit.


Asunto(s)
Diagnóstico Tardío , Trastorno del Dedo en Gatillo , Humanos , Femenino , Trastorno del Dedo en Gatillo/diagnóstico , Niño , Rango del Movimiento Articular , Pulgar/fisiopatología
7.
Sci Rep ; 14(1): 10428, 2024 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-38714762

RESUMEN

Muscle strength assessments are vital in rehabilitation, orthopedics, and sports medicine. However, current methods used in clinical settings, such as manual muscle testing and hand-held dynamometers, often lack reliability, and isokinetic dynamometers (IKD), while reliable, are not easily portable. The aim of this study was to design and validate a wearable dynamometry system with high accessibility, accuracy, and reliability, and to validate the device. Therefore, we designed a wearable dynamometry system (WDS) equipped with knee joint torque sensors. To validate this WDS, we measured knee extension and flexion strength in 39 healthy adults using both the IKD and WDS. Comparing maximal isometric torque measurements, WDS and IKD showed strong correlation and good reliability for extension (Pearson's r: 0.900; intraclass correlation coefficient [ICC]: 0.893; standard error of measurement [SEM]: 9.85%; minimal detectable change [MDC]: 27.31%) and flexion (Pearson's r: 0.870; ICC: 0.857; SEM: 11.93%; MDC: 33.07%). WDS demonstrated excellent inter-rater (Pearson's r: 0.990; ICC: 0.993; SEM: 4.05%) and test-retest (Pearson's r: 0.970; ICC: 0.984; SEM: 6.15%) reliability during extension/flexion. User feedback from 35 participants, including healthcare professionals, underscores WDS's positive user experience and clinical potential. The proposed WDS is a suitable alternative to IKD, providing high accuracy, reliability, and potentially greater accessibility.


Asunto(s)
Articulación de la Rodilla , Dinamómetro de Fuerza Muscular , Fuerza Muscular , Torque , Dispositivos Electrónicos Vestibles , Humanos , Masculino , Adulto , Femenino , Articulación de la Rodilla/fisiología , Fuerza Muscular/fisiología , Reproducibilidad de los Resultados , Rango del Movimiento Articular/fisiología , Adulto Joven , Diseño de Equipo
8.
Sci Rep ; 14(1): 10437, 2024 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-38714766

RESUMEN

The Waveflex semi-rigid-dynamic-internal-fixation system shows good short-term effects in the treatment of lumbar degenerative diseases, but there are few long-term follow-up studies, especially for recovery of sagittal balance. Fifty patients with lumbar degenerative diseases treated from January 2016 to October 2017 were retrospectively analysed: 25 patients treated with Waveflex semi-rigid-dynamic-internal-fixation system (Waveflex group) and 25 patients treated with double-segment PLIF (PLIF group). Clinical efficacy was evaluated by Visual Analogue Scale (VAS) and Oswestry Disability Index (ODI). Imaging data before surgery and at 3 months, 1 year, and 5 years postoperatively was used for imaging indicator assessment. Local disc degeneration of the cephalic adjacent segment (including disc height index (DHI), intervertebral foramen height (IFH), and range of motion (ROM)) and overall spinal motor function (including lumbar lordosis (LL), pelvic incidence (PI), sacral slope (SS), pelvic tilt (PT), and |PI-LL|) were analysed. Regarding clinical efficacy, comparison of VAS and ODI scores between the Waveflex and PLIF groups showed no significant preoperative or postoperative differences. The comparison of the objective imaging indicators showed no significant differences in the DHI, IFH, LL, |PI-LL|, and SS values between the Waveflex and PLIF groups preoperatively and 3 months postoperatively (P > 0.05). These values were significantly different at 1 and 5 years postoperatively (P < 0.05), and the Waveflex group showed better ROM values than those of the PLIF group (P < 0.05). PI values were not significantly different between the groups, but PT showed a significant improvement in the Waveflex group 5 years postoperatively (P < 0.05). The Waveflex semi-rigid dynamic fixation system can effectively reduce the probability of intervertebral disc degeneration in upper adjacent segments. Simultaneously, patients in the Waveflex group showed postoperative improvements in LL, spinal sagittal imbalance, and quality of life.


Asunto(s)
Degeneración del Disco Intervertebral , Vértebras Lumbares , Humanos , Masculino , Femenino , Degeneración del Disco Intervertebral/cirugía , Degeneración del Disco Intervertebral/diagnóstico por imagen , Persona de Mediana Edad , Estudios Retrospectivos , Vértebras Lumbares/cirugía , Vértebras Lumbares/diagnóstico por imagen , Resultado del Tratamiento , Adulto , Rango del Movimiento Articular , Fusión Vertebral/métodos , Anciano , Fijadores Internos , Lordosis/diagnóstico por imagen , Lordosis/cirugía
9.
J Orthop Surg Res ; 19(1): 273, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38698477

RESUMEN

BACKGROUND: Talar malignant tumor is extremely rare. Currently, there are several alternative management options for talus malignant tumor including below-knee amputation, tibio-calcaneal arthrodesis, and homogenous bone transplant while their shortcomings limited the clinical application. Three-dimensional (3D) printed total talus prosthesis in talus lesion was reported as a useful method to reconstruct talus, however, most researches are case reports and its clinical effect remains unclear. Therefore, the current study was to explore the application of 3D printed custom-made modular prosthesis in talus malignant tumor. METHODS: We retrospectively analyzed the patients who received the 3D printed custom-made modular prosthesis treatment due to talus malignant tumor in our hospital from February 2016 to December 2021. The patient's clinical data such as oncology outcome, operation time, and volume of blood loss were recorded. The limb function was evaluated with the Musculoskeletal Tumor Society 93 (MSTS-93) score, The American Orthopedic Foot and Ankle Society (AOFAS) score; the ankle joint ranges of motion as well as the leg length discrepancy were evaluated. Plain radiography and Tomosynthesis-Shimadzu Metal Artefact Reduction Technology (T-SMART) were used to evaluate the position of prosthesis and the osseointegration. Postoperative complications were recorded. RESULTS: The average patients' age and the follow-up period were respectively 31.5 ± 13.1 years; and 54.8 months (range 26-72). The medium operation time was 2.4 ± 0.5 h; the intraoperative blood loss was 131.7 ± 121.4 ml. The mean MSTS-93 and AOFAS score was 26.8 and 88.5 respectively. The average plantar flexion, dorsiflexion, varus, and valgus were 32.5, 9.2, 10.8, and 5.8 degree respectively. One patient had delayed postoperative wound healing. There was no leg length discrepancy observed in any patient and good osseointegration was observed on the interface between the bone and talus prosthesis in all subjects. CONCLUSION: The modular structure of the prosthesis developed in this study seems to be convenient for prosthesis implantation and screws distribution. And the combination of solid and porous structure improves the initial stability and promotes bone integration. Therefore, 3D printed custom-made modular talus prosthesis could be an alternative option for talus reconstruction in talus malignant tumor patients.


Asunto(s)
Neoplasias Óseas , Impresión Tridimensional , Diseño de Prótesis , Astrágalo , Humanos , Astrágalo/cirugía , Astrágalo/diagnóstico por imagen , Masculino , Adulto , Femenino , Neoplasias Óseas/cirugía , Neoplasias Óseas/diagnóstico por imagen , Estudios Retrospectivos , Persona de Mediana Edad , Adulto Joven , Implantación de Prótesis/métodos , Implantación de Prótesis/instrumentación , Adolescente , Articulación del Tobillo/cirugía , Articulación del Tobillo/diagnóstico por imagen , Oseointegración , Resultado del Tratamiento , Rango del Movimiento Articular , Prótesis e Implantes
10.
J Orthop Surg Res ; 19(1): 282, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38711065

RESUMEN

BACKGROUND: The aim of this study was to compare the effects of four different immobilization methods [single sugar tong splint (SSTS), double sugar tong splint (DSTS), short arm cast (SAC), and long arm cast (LAC)] commonly used for restricting forearm rotation in the upper extremity. METHODS: Forty healthy volunteers were included in the study. Dominant extremities were used for measurements. Basal pronation and supination of the forearm were measured with a custom-made goniometer, and the total rotation arc was calculated without any immobilization. Next, the measurements were repeated with the SAC, LAC, SSTS and DSTS. Each measurement was compared to the baseline value, and the percentage of rotation restriction was calculated. RESULTS: The most superior restriction rates were observed for the LAC (p = 0.00). No statistically significant difference was detected between the SSTS and DSTS in terms of the restriction of supination, pronation or the rotation arc (p values, 1.00, 0.18, and 0.50, respectively). Statistically significant differences were not detected between the SAC and the SSTS in any of the three parameters (p values, 0.25; 1.00; 1.00, respectively). When the SAC and DSTS were compared, while there was no significant difference between the two methods in pronation (p = 0.50), a statistically significant difference was detected in supination (p = 0.01) and in the total rotation arc (p = 0.03). CONCLUSION: The LAC provides superior results in restricting forearm rotation. The SAC and SSTS had similar effects on forearm rotation. The DSTS, which contains, in addition to the SSTS, a sugar tong portion above the elbow, does not provide additional rotational stability.


Asunto(s)
Antebrazo , Inmovilización , Férulas (Fijadores) , Humanos , Masculino , Femenino , Adulto , Rotación , Antebrazo/fisiología , Adulto Joven , Inmovilización/métodos , Supinación/fisiología , Pronación/fisiología , Moldes Quirúrgicos , Voluntarios Sanos , Rango del Movimiento Articular/fisiología
11.
BMC Musculoskelet Disord ; 25(1): 382, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38745166

RESUMEN

BACKGROUND: An isokinetic moment curve (IMC) pattern-damaged structure prediction model may be of considerable value in assisting the diagnosis of knee injuries in clinical scenarios. This study aimed to explore the association between irregular IMC patterns and specific structural damages in the knee, including anterior cruciate ligament (ACL) rupture, meniscus (MS) injury, and patellofemoral joint (PFJ) lesions, and to develop an IMC pattern-damaged structure prediction model. METHODS: A total of 94 subjects were enrolled in this study and underwent isokinetic testing of the knee joint (5 consecutive flexion-extension movements within the range of motion of 90°-10°, 60°/s). Qualitative analysis of the IMCs for all subjects was completed by two blinded examiners. A multinomial logistic regression analysis was used to investigate whether a specific abnormal curve pattern was associated with specific knee structural injuries and to test the predictive effectiveness of IMC patterns for specific structural damage in the knee. RESULTS: The results of the multinomial logistic regression revealed a significant association between the irregular IMC patterns of the knee extensors and specific structural damages ("Valley" - ACL, PFJ, and ACL + MS, "Drop" - ACL, and ACL + MS, "Shaking" - ACL, MS, PFJ, and ACL + MS). The accuracy and Macro-averaged F1 score of the predicting model were 56.1% and 0.426, respectively. CONCLUSION: The associations between irregular IMC patterns and specific knee structural injuries were identified. However, the accuracy and Macro-averaged F1 score of the established predictive model indicated its relatively low predictive efficacy. For the development of a more accurate predictive model, it may be essential to incorporate angle-specific and/or speed-specific analyses of qualitative and quantitative data in isokinetic testing. Furthermore, the utilization of artificial intelligence image recognition technology may prove beneficial for analyzing large datasets in the future.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Articulación de la Rodilla , Rango del Movimiento Articular , Humanos , Masculino , Femenino , Adulto , Rango del Movimiento Articular/fisiología , Articulación de la Rodilla/fisiopatología , Lesiones del Ligamento Cruzado Anterior/fisiopatología , Adulto Joven , Fenómenos Biomecánicos/fisiología , Traumatismos de la Rodilla/fisiopatología , Valor Predictivo de las Pruebas , Lesiones de Menisco Tibial/fisiopatología , Articulación Patelofemoral/fisiopatología , Articulación Patelofemoral/lesiones , Persona de Mediana Edad
12.
BMC Surg ; 24(1): 155, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38745183

RESUMEN

OBJECTIVE: The relationships between preoperative cervical spine range of motion (ROM) and postoperative cervical sagittal alignment (CSA), and clinical outcomes after laminoplasty (LMP) have been widely studied. However, the impact of ROM changes on postoperative CSA and clinical outcomes after LMP remains unclear. Herein, patients with cervical spondylotic myelopathy (CSM) were retrospectively analyzed to explore the association between postoperative cervical ROM changes and CSA and surgical outcomes. METHODS: Patients who underwent cervical LMP at our hospital between January 2019 to June 2022 were retrospectively reviewed. CSA parameters were measured before the surgery and at the final follow-up. Loss of cervical lordosis (LCL) was defined as preoperative cervical lordosis (CL) - postoperative CL. An increase in the cervical sagittal vertical axis (I-cSVA) was defined as postoperative cervical sagittal vertical axis (cSVA) - preoperative cSVA. We defined the changes in cervical flexion range of motion (△Flex ROM, preoperative Flex ROM minus postoperative Flex ROM) > 10° as L- Flex ROM group, and △Flex ROM ≤ 10° as S- Flex ROM group. Japanese Orthopedic Association (JOA) score and visual analog score (VAS) were used to assess the surgical outcomes. RESULTS: The study comprised 74 patients and the average follow-up period was 31.83 months. CL, total ROM, and Flex ROM decreased and cSVA increased after cervical LMP. LCL and I-cSVA were positively correlated with △Flex. Multiple linear regression analysis showed that a decrease in the Flex ROM was a risk factor for LCL and I-cSVA after LMP. LCL and I-cSVA were higher in the L-Flex ROM group than in the S-Flex ROM group. Postoperative JOA and the JOA recovery rate were worse in the L-Flex ROM group than in the S-Flex ROM group. CONCLUSIONS: Cervical total and Flex ROM decreased after cervical LMP. The reduction of Flex ROM was associated with LCL and I-cSVA after surgery. The preservation of cervical Flex ROM helps maintain CSA after LMP. Therefore, more attention should be paid to maintaining cervical ROM to obtain good CSA and surgical effects after cervical LMP.


Asunto(s)
Vértebras Cervicales , Laminoplastia , Rango del Movimiento Articular , Humanos , Laminoplastia/métodos , Vértebras Cervicales/cirugía , Femenino , Rango del Movimiento Articular/fisiología , Masculino , Estudios Retrospectivos , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Espondilosis/cirugía , Espondilosis/fisiopatología , Periodo Posoperatorio , Lordosis/fisiopatología , Adulto , Enfermedades de la Médula Espinal/cirugía , Enfermedades de la Médula Espinal/fisiopatología , Estudios de Seguimiento
13.
PLoS One ; 19(5): e0302885, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38739584

RESUMEN

BACKGROUND: The Vega System® PS (Aesculap AG, Tuttlingen, Germany) is an advanced, third generation fixed implant that aims to mimic natural knee kinematics by optimizing pivotal motion while reducing surface stress. This study evaluated mid-term survival and clinical outcomes, including range of motion (ROM) of the modern posterior stabilized implant in order to analyse whether this biomechanically successful implant reaches good results in situ. METHODS: The first 100 patients to receive the Vega PS System for total knee arthroplasty were invited to take part in this single centre, single surgeon study. Of these, 84 patients were clinically assessed 5-6 years postoperatively. Data which was obtained during this follow-up examination included revision data, range of motion and clinical scores. RESULTS: The 5-year survival rate for exchange of any component was 97.6%, whereby two patients required replacement of the polyethylene gliding surface. Secondary patella resurfacing was performed in 7 patients. Significantly improved results in comparison to the preoperative state could be obtained at the follow-up: KOOS improved from 39.4 to 78.8, SF-12 PCS improved from 32.1 to 42 SF-12 MCS improved from 46 to 53.8 and patella pain improved from 2.7 to 0.3. The mean ROM of the 84 patients after 5 years was 133.1° and mean total KSS was 189.9. DISCUSSION & CONCLUSIONS: This study demonstrates a high survival rate of the Vega PS System® and significant improvements in clinical outcomes 5 years after implantation. The obtained mean ROM indicates that this implant provides good flexibility of the knee joint, allowing a high number of activities. However, due to the rate of secondary patella implantation, routine resurfacing of the patella for all PS TKA cases is highly recommended. CLINICAL TRIALS REGISTRATION: The study was registered at clinicaltrials.gov (NCT02802085).


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Rango del Movimiento Articular , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Femenino , Masculino , Anciano , Estudios de Seguimiento , Persona de Mediana Edad , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiopatología , Anciano de 80 o más Años , Actividades Cotidianas , Fenómenos Biomecánicos , Resultado del Tratamiento , Diseño de Prótesis
14.
PLoS One ; 19(5): e0302922, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38739595

RESUMEN

Handstand is a basic element common across gymnastic disciplines and physical education classes that is frequently evaluated for quality in competition or skill acquisition. The correct handstand execution relies on maintaining balance, for which the shoulders seem particularly important. This study explores the relationship between shoulder joint function and the quality of handstand execution in novice college athletes (n = 111; aged 19-23 years). We assessed the shoulder joint function using standardized field tests (Upper Quarter Y Balance Test and Closed Kinetic Chain Upper Extremity Stability Test) and evaluated handstand execution on official rating scale. Ordinal logistic regression models showed no relationship between the quality of handstand execution (E-score) and measures of shoulder joint stability or mobility in our sample (POR = 0.97 [0.91, 1.03] and 1.00 [0.91, 1.09] for E-score). Two major factors may have caused an observed pattern of results. Firstly, the standardized tests assess shoulder joints in different loads and ranges of motion compared to handstands. Secondly, our novice sample was not able to perform the handstand sufficiently well. In our sample of novice college athletes, shoulder function seems not related to handstand execution as other latent factors hindered their performance.


Asunto(s)
Rango del Movimiento Articular , Articulación del Hombro , Humanos , Masculino , Adulto Joven , Femenino , Articulación del Hombro/fisiología , Rango del Movimiento Articular/fisiología , Atletas , Gimnasia/fisiología , Adulto , Rendimiento Atlético/fisiología
15.
Jt Dis Relat Surg ; 35(2): 285-292, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38727106

RESUMEN

OBJECTIVES: The study aimed to investigate the factors associated with shoulder stiffness following open reduction and internal fixation (ORIF) of proximal humeral fractures. PATIENTS AND METHODS: The retrospective study included a total of 151 patients who underwent ORIF of proximal humeral fractures between January 2016 and May 2021. Based on their shoulder joint motion at the latest follow-up, the patients were divided into two groups. The stiffness group (n=32; 8 males, 24 females; mean age: 62.4±9.3 years; range, 31 to 79 years), exhibited restricted shoulder forward flexion (<120°), limited arm lateral external rotation (<30°), and reduced back internal rotation below the L3 level. The remaining patients were included in the non-stiffness group (n=119; 52 males, 67 females; mean age: 56.4±13.4 years; range, 18 to 90 years). Various factors were examined to evaluate the association with shoulder stiffness following ORIF of proximal humeral fractures by multivariate unconditional logistic regression models. RESULTS: The mean follow-up duration was 31.8±12.6 (range, 12 to 68) months. Based on the results of the multivariate regression analysis, it was found that high-energy injuries [compared to low-energy injuries; adjusted odds ratio (aOR)=7.706, 95% confidence interval (CI): 3.564-15.579, p<0.001], a time from injury to surgery longer than one week (compared to a time from injury to surgery equal to or less than one week; aOR=5.275, 95% CI: 1.7321-9.472, p=0.031), and a body mass index (BMI) >24.0 kg/m2 (compared to a BMI between 18.5 and 24.0 kg/m2 ; aOR=4.427, 95% CI: 1.671-11.722, p=0.023) were identified as risk factors for shoulder stiffness following ORIF of proximal humeral fractures. CONCLUSION: High-energy injury, time from injury to surgery longer than one week, and BMI >24.0 kg/m2 were identified as independent risk factors for shoulder stiffness after proximal humeral fracture surgery, which should be treated with caution in clinical treatment.


Asunto(s)
Fijación Interna de Fracturas , Reducción Abierta , Rango del Movimiento Articular , Fracturas del Hombro , Humanos , Masculino , Persona de Mediana Edad , Fracturas del Hombro/cirugía , Femenino , Anciano , Estudios Retrospectivos , Adulto , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/métodos , Reducción Abierta/métodos , Reducción Abierta/efectos adversos , Articulación del Hombro/cirugía , Articulación del Hombro/fisiopatología , Anciano de 80 o más Años , Factores de Riesgo , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/epidemiología , Adulto Joven
16.
Jt Dis Relat Surg ; 35(2): 422-432, 2024 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-38727124

RESUMEN

Distal femoral varus osteotomy (DFVO) is a widely recognized surgical procedure used to address valgus malalignment in patients with knee joint disorders. However, it still remains unclear whether anterior cruciate ligament (ACL) reconstruction can be performed in a single procedure along with DFVO. Herein, we present a 73-year-old female patient who developed lateral osteoarthritis of the knee with valgus alignment due to chronic ACL deficiency following a twisting injury during skiing. She was physiologically very active, and strongly demanded to return to sports. We performed a combined procedure involving a medial closing wedge DFVO using an anatomical locking plate, along with double-bundle ACL reconstruction. The postoperative radiograph confirmed successful correction of knee alignment, specifically achieving varus alignment with precise conformance of the anatomical plate to the medial contour of the distal femur following the osteotomy. The patient resumed her previous sports activities without experiencing knee pain. The operated knee demonstrated restored anterior stability, as indicated by negative Lachman test results, and regained full range of motion. Both the Knee Injury and Osteoarthritis Outcome Score and the 2011 Knee Society score demonstrated continuous postoperative improvements over the three-year follow-up period, indicating positive functional outcomes and joint preservation. To the best of our knowledge, this is the first case of medial closing wedge DFVO with anatomic double-bundle ACL reconstruction in the symptomatic femoral valgus deformity with chronic ACL deficiency in the literature.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior , Fémur , Osteoartritis de la Rodilla , Osteotomía , Humanos , Femenino , Osteotomía/métodos , Anciano , Fémur/cirugía , Reconstrucción del Ligamento Cruzado Anterior/métodos , Osteoartritis de la Rodilla/cirugía , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/anomalías , Articulación de la Rodilla/diagnóstico por imagen , Lesiones del Ligamento Cruzado Anterior/cirugía , Lesiones del Ligamento Cruzado Anterior/complicaciones , Resultado del Tratamiento , Rango del Movimiento Articular
17.
Jt Dis Relat Surg ; 35(2): 396-403, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38727120

RESUMEN

OBJECTIVES: This study aimed to compare the functional outcomes of patients undergoing fixed-bearing medial unicompartmental knee arthroplasty (UKA) classified as either varus or neutral based on their postoperative femorotibial angle (FTA), with the goal of evaluating the impact of FTA on functional results. PATIENTS AND METHODS: A total of 38 knees of 35 patients (27 females, 8 males; mean age: 63.6±7.1 years; range, 52 to 75 years) were included in this retrospective study. The data was collected between December 15, 2020, and January 15, 2021. Patients were categorized into two groups based on their postoperative FTA. The neutral group consisted of patients with an FTA range of 5.1° to 7.4°, while the varus group included patients with an FTA range of 0.1° to 4.8°. Knee Outcome Osteoarthritis Score (KOOS), Visual Analog Scale (VAS) scores, sit to stand test results, and six minute walk test data were analyzed. RESULTS: The mean follow-up was 42.0±19.3 months. The postoperative VAS score for the varus group was 0.95±0.99, whereas the neutral group had a VAS score of 2.19±1.83 (p=0.021). The mean KOOS for the varus group was 88.01±7.88, whereas the neutral group had a mean KOOS score of 78.46±13.69 (p=0.006). CONCLUSION: In patients undergoing UKA, mild varus alignment could yield superior early and midterm functional outcomes compared to a neutral femorotibial angle.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Fémur , Osteoartritis de la Rodilla , Humanos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Osteoartritis de la Rodilla/cirugía , Osteoartritis de la Rodilla/fisiopatología , Fémur/cirugía , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiopatología , Rango del Movimiento Articular , Resultado del Tratamiento , Tibia/cirugía , Prótesis de la Rodilla , Recuperación de la Función
18.
Jt Dis Relat Surg ; 35(2): 410-416, 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38727122

RESUMEN

Congenital radial head subluxation is relatively rare and may be overlooked due to mild symptoms. The diagnosis mainly relies on imaging and history. Observation is an option for those with insignificant symptoms, while surgical intervention, such as ulnar osteotomy or arthroscopy, is often required when dysfunction exists. A 30-year-old man was admitted with congenital radial head dislocation, which was treated with manipulative repositioning. During follow-up, the patient regained the original mobility of the elbow joint and had no recurrence of dislocation. In conclusion, in adults with congenital dislocation of the radial head, we recommend conservative treatment as a first step.


Asunto(s)
Tratamiento Conservador , Articulación del Codo , Luxaciones Articulares , Radio (Anatomía) , Humanos , Masculino , Adulto , Articulación del Codo/cirugía , Articulación del Codo/diagnóstico por imagen , Luxaciones Articulares/congénito , Luxaciones Articulares/terapia , Luxaciones Articulares/cirugía , Luxaciones Articulares/diagnóstico por imagen , Tratamiento Conservador/métodos , Radio (Anatomía)/anomalías , Radio (Anatomía)/diagnóstico por imagen , Radio (Anatomía)/cirugía , Rango del Movimiento Articular , Resultado del Tratamiento , Manipulación Ortopédica/métodos
19.
Jt Dis Relat Surg ; 35(2): 448-454, 2024 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-38727128

RESUMEN

Several surgical procedures are used to treat dynamic pronation position of the forearm and flexion deformity of the wrist in cerebral palsy. Postoperative results of pronator teres rerouting were explored, while specially designed postoperative physiotherapy and its outcomes were limited. Herein, we present a case in whom the outcomes of electromyographic biofeedback (EMG-BF) training were assessed after pronator teres rerouting and brachioradialis tendon to extensor carpi radialis brevis tendon transfer combined with derotation osteotomy. The peak value increased, while the resting value decreased for the muscles after the intervention. Range of motion, hand function, manual ability, functional independence, and quality of life levels were improved. In conclusion, EMG biofeedback training may have a positive effect on neuromuscular control of pronator teres and brachioradialis. Free use of the upper extremity and improved manual ability positively affect the activity and quality of life of the patients.


Asunto(s)
Parálisis Cerebral , Músculo Esquelético , Rango del Movimiento Articular , Transferencia Tendinosa , Humanos , Transferencia Tendinosa/métodos , Parálisis Cerebral/cirugía , Parálisis Cerebral/rehabilitación , Parálisis Cerebral/fisiopatología , Músculo Esquelético/cirugía , Músculo Esquelético/fisiopatología , Masculino , Antebrazo/cirugía , Electromiografía , Calidad de Vida , Resultado del Tratamiento , Biorretroalimentación Psicológica/métodos , Osteotomía/métodos , Pronación/fisiología , Recuperación de la Función/fisiología
20.
Lasers Med Sci ; 39(1): 124, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38709332

RESUMEN

The purpose of this systematic review was to evaluate the effects of high-intensity laser therapy (HILT) on pain, disability, and range of movement in patients with neck pain. Randomized controlled trials (RCTs) of HILT for neck pain disorders were searched across databases such as PubMed, Web of Science, Scopus, CINAHL, Science Direct, Cochrane Library, the PEDro database, and Google Scholar (updated January 7, 2024). The main outcome was pain intensity, with neck disability and cervical range of motion as secondary outcomes. Researchers reviewed article titles and abstracts from different databases using the Rayyan web app. Study quality was assessed using the Cochrane risk of bias tool, and evidence-based recommendations were developed using the GRADE approach. A meta-analysis was conducted to calculate the pooled effect in terms of mean differences (MD) for the outcomes of interest, along with a 95% confidence interval (95% CI). Twenty studies met the selection criteria and were potentially eligible for inclusion in the meta-analysis. At the end of the treatment, there was a statistically significant (p < 0.01) pooled MD of -14.1 mm for pain intensity (17 RCTs) with the VAS (95% CI:-18.4,-9.7), 3.9° (95% CI:1.9,6.7) for cervical extension (9 RCTs), and -8.3% (95% CI:-14.1,-4.1) for disability diminish (12 RCTs) with the neck disability index in favor of HILT. Only the results for pain intensity are in line with the minimal clinically important differences (MCID) reported in the literature. Overall, the evidence was deemed significant but with low certainty, attributed to observed heterogeneity and some risk of bias among the RCTs. HILT demonstrates effectiveness in reducing neck pain and disability while enhancing cervical extension when added to other physical therapy interventions, especially therapeutic exercise, based on a moderate level of evidence. This review highlights that the most favorable results are obtained when HILT is employed to address myofascial pain, cervical radiculopathy and chronic neck pain.PROSPERO registration number: CRD42023387394 (Registration date, 14/01/2023).


Asunto(s)
Dolor de Cuello , Ensayos Clínicos Controlados Aleatorios como Asunto , Humanos , Dolor de Cuello/radioterapia , Dolor de Cuello/terapia , Terapia por Láser/métodos , Resultado del Tratamiento , Rango del Movimiento Articular , Dimensión del Dolor
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...