Resultados 1 - 20 de 3.073
Filtrar
1.
BMC Urol ; 24(1): 77, 2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38570777

RESUMEN

BACKGROUND: This study aimed to evaluate the intrarenal pelvic pressure in endoscopic combined intrarenal surgery using an artificial kidney model. METHODS: An artificial kidney model was created using the Urovac evacuator™. Four sizes of nephrostomy sheaths (MIP-L: 25/26 Fr, MIP-M: 16.5/17.5 Fr, MIP-S: 11/12 Fr, MIP-XS: 8.5/9.5 Fr) and two sizes of ureteral access sheaths (12/14 Fr and 10/12 Fr) were installed into the model. For each combination of nephrostomy and ureteral access sheath, renal pelvic pressure was measured with and without insertion of the retrograde flexible ureteroscope. Irrigation from the nephroscope was adjusted to 40-160 mmHg using an automatic irrigation device, and the irrigation of the ureteroscope was by spontaneous dripping at 80 cmH2O. Conditions were measured six times, and the renal pelvic pressure was compared in different conditions. RESULTS: Without ureteroscope insertion through the ureteral access sheath, the renal pelvic pressure never exceeded 30 mmHg. Meanwhile, when the ureteroscope was inserted, the renal pelvic pressure increased as the nephrostomy sheath and ureteral access sheath became narrower and as the irrigation pressure increased. Intrarenal pelvic pressure exceeded 30 mmHg when the irrigation pressure was increased in 12/14 Fr ureteral access sheath when MIP-XS was used, and in 10/12 Fr ureteral access sheath when MIP-XS and MIP-S were used. CONCLUSIONS: The use of a thin nephrostomy sheath in endoscopic combined intrarenal surgery can lead to increased intrarenal pelvic pressure. Although our results are from an artificial kidney model, special care is suggested to be required when using a retrograde flexible ureteroscope simultaneously in treatment of patients.


Asunto(s)
Cálculos Renales , Riñones Artificiales , Uréter , Humanos , Ureteroscopía/métodos , Pelvis Renal/cirugía , Riñón/cirugía , Uréter/cirugía , Ureteroscopios , Cálculos Renales/cirugía , Nefrotomía
2.
Infect Dis Health ; 29(2): 107-111, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38485528

RESUMEN

BACKGROUND: To reduce the risk of viral transmission, guidelines recommend the use of designated haemodialysis machines and patient isolation for patients with chronic hepatitis B virus (HBV). These practices are without a strong evidence base, and may no longer be necessary in the setting of heat disinfection programs and standard precautions. METHODS: An online cross-sectional survey was developed for renal clinicians across Australia and New Zealand to explore infection prevention policy concerning patients with chronic HBV in haemodialysis units. We sought to determine whether psychosocial and cultural impacts might result from the mandatory use of machine designation and patient isolation practices, as perceived by multidisciplinary healthcare workers with experience working with this patient population. RESULTS: Sixty-seven responses from 27 health districts across all states of Australia and one New Zealand district were received. Most respondents were from urban areas (65%), and were nurses (87%). 50% of health districts reported using designated machines, while 32% isolate patients. Lack of necessary resources limited the use of designated machines (57%), and patient isolation (78%). Respondents not routinely using these precautions were more likely to express concerns regarding patient psychosocial wellbeing and cultural appropriateness. Overall, 30% of respondents expressed concerns regarding the cultural appropriateness of these recommendations. CONCLUSION: We demonstrate wide variation in haemodialysis infection prevention and control policy and practice with regards to managing patients with chronic HBV. While use of standard precautions and machine disinfection are consistently applied, resource availability and concerns for patient psychosocial wellbeing limit adherence to international guidelines.


Asunto(s)
Hepatitis B Crónica , Riñones Artificiales , Virosis , Humanos , Diálisis Renal , Australia , Estudios Transversales , Virosis/prevención & control , Aislamiento de Pacientes , Encuestas y Cuestionarios
3.
Clin J Am Soc Nephrol ; 19(4): 517-524, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-37639246

RESUMEN

Writing a home hemodialysis (HD) prescription is a complex, multifactorial process that requires the incorporation of patient values, preferences, and lifestyle. Knowledge of the different options available for home HD modality (conventional, nocturnal, short daily, and alternate nightly) is also important when customizing a prescription. Finally, an understanding of the different home HD machines currently approved for use at home and their different attributes and limitations helps guide providers when formulating their prescriptions. In this review article, we set out to address these different aspects to help guide providers in providing a patient-centered home HD approach.


Asunto(s)
Fallo Renal Crónico , Riñones Artificiales , Humanos , Hemodiálisis en el Domicilio , Diálisis Renal , Prescripciones , Atención Dirigida al Paciente
4.
Int J Urol ; 31(2): 177-181, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37888949

RESUMEN

OBJECTIVES: This study compares intrapelvic pressure (IPP) during retrograde intrarenal surgery with various single-use flexible ureteroscopes (f-URS) in an artificial kidney model. METHODS: We created an artificial kidney model with a pressure sensor using a bladder evacuation device. The model was completely closed and the only backflow was on the side of the ureteroscope inside the ureteral access sheath (UAS). We tested five single-use f-URSs (LithoVue, Wiscope, PU3022A, PU3033A, and AXIS) with six different types of UAS (9.5/11.5-14/16 Fr). Using the automatic irrigation system, 30 s of irrigation was performed at various pressures (40-180 mmHg) and steady-state IPP was recorded. IPP was compared between the five single-use f-URSs. IPP cutoff value was determined at 30 mmHg. The diameter of the endoscope tip and the curved and shaft parts were also measured and recorded. RESULTS: The diameters of all parts were significantly different between single-use f-URSs. The maximum IPP tended to be higher in ureteroscopes with larger diameters of the proximal parts (curved part/shaft part). In LithoVue and Uscope PU3022A f-URSs, the maximum IPP did not exceed 30 mmHg when UAS ≥12/14 Fr was used. In AXIS and Wiscope f-URSs, it did not exceed the cutoff value when the UAS ≥11/13 Fr was used. In Uscope PU3033A f-URS, it did not exceed 30 mmHg when the UAS ≥10/12 Fr was used. CONCLUSIONS: Maximum IPP tended to be higher in f-URSs with larger diameters of the proximal part and the appropriate size of the UAS differed between various single-use f-URSs.


Asunto(s)
Cálculos Renales , Riñones Artificiales , Uréter , Humanos , Ureteroscopios , Ureteroscopía , Cálculos Renales/cirugía , Presión , Diseño de Equipo , Uréter/cirugía
5.
Artif Organs ; 48(4): 365-374, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37962073

RESUMEN

BACKGROUND: Clearum™ is a high flux steam sterilized dialyzer for patients with hemodialysis or hemodiafiltration. This study evaluated the safety and performance of the Clearum high flux steam sterilized hemodialyzer in the removal of small and middle-sized toxins. METHODS: A prospective, interventional, nonrandomized study enrolled twenty end-stage renal disease patients undergoing hemodialysis. The Clearum high flux steam sterilized dialyzer was compared to Fresenius FX dialyzers for baseline comparison. The duration of the trial was 2 weeks for the FX dialyzer and 6 weeks with the Clearum high flux steam sterilized dialyzer. In vitro studies with dextrans of varying sizes were performed to compare the membrane characteristics and sieving coefficient curves for the two dialyzers. RESULTS: The primary objective of a mean urea reduction ratio >65% was met, with no significant difference in mean urea reduction ratio between the Clearum high flux steam sterilized and Fresenius FX-series of dialyzers (p = 0.86). No dialyzer-related adverse events were reported in the study. ß-2-microglobulin reduction with the Clearum high flux steam sterilized dialyzer was statistically higher than the FX-series dialyzer (66.5% vs. 53.6%; p < 0.0001). Predialysis interleukin-6 and C-reactive protein concentrations, blood-rest scores (residual blood after blood restitution), and thrombin-anti-thrombin values were comparable. Albumin remained stable during the 6 weeks of Clearum high flux steam sterilized dialyzer use, with no appreciable differences compared to the Fresenius FX-series. CONCLUSION: The Clearum high flux steam sterilized dialyzer showed good mid-term effectivity for small and middle molecule removal with no reported dialyzer-related adverse events.


Asunto(s)
Riñones Artificiales , Humanos , Estudios Prospectivos , Vapor , Diálisis Renal/efectos adversos , Membranas Artificiales , Urea
6.
Artif Organs ; 48(2): 115-116, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37970710

RESUMEN

Dialysis remains an imperfect treatment for over two million patients with renal failure worldwide. This bioreactor may lead to the completely implantable, continuous filtration system they need.


Asunto(s)
Fallo Renal Crónico , Riñones Artificiales , Humanos , Animales , Porcinos , Diálisis Renal , Filtración , Terapia de Inmunosupresión , Riñón , Fallo Renal Crónico/terapia
7.
Toxins (Basel) ; 15(9)2023 09 04.
Artículo en Inglés | MEDLINE | ID: mdl-37755973

RESUMEN

Reliable models of renal failure in large animals are critical to the successful translation of the next generation of renal replacement therapies (RRT) into humans. While models exist for the induction of renal failure, none are optimized for the implantation of devices to the retroperitoneal vasculature. We successfully piloted an embolization-to-implantation protocol enabling the first implant of a silicon nanopore membrane hemodialyzer (SNMHD) in a swine renal failure model. Renal arterial embolization is a non-invasive approach to near-total nephrectomy that preserves retroperitoneal anatomy for device implants. Silicon nanopore membranes (SNM) are efficient blood-compatible membranes that enable novel approaches to RRT. Yucatan minipigs underwent staged bilateral renal arterial embolization to induce renal failure, managed by intermittent hemodialysis. A small-scale arteriovenous SNMHD prototype was implanted into the retroperitoneum. Dialysate catheters were tunneled externally for connection to a dialysate recirculation pump. SNMHD clearance was determined by intermittent sampling of recirculating dialysate. Creatinine and urea clearance through the SNMHD were 76-105 mL/min/m2 and 140-165 mL/min/m2, respectively, without albumin leakage. Normalized creatinine and urea clearance measured in the SNMHD may translate to a fully implantable clinical-scale device. This pilot study establishes a path toward therapeutic testing of the clinical-scale SNMHD and other implantable RRT devices.


Asunto(s)
Riñones Artificiales , Insuficiencia Renal , Humanos , Porcinos , Animales , Creatinina , Proyectos Piloto , Silicio , Porcinos Enanos , Soluciones para Diálisis , Urea
8.
Toxins (Basel) ; 15(7)2023 07 20.
Artículo en Inglés | MEDLINE | ID: mdl-37505734

RESUMEN

Bisphenol A (BPA)-based materials are used in the manufacturing of hemodialyzers, including their polycarbonate (PC) housings and polysulfone (PS) membranes. As concerns for BPA's adverse health effects rise, the regulation on BPA exposure is becoming more rigorous. Therefore, BPA alternatives, such as Bisphenol S (BPS), are increasingly used. It is important to understand the patient risk of BPA and BPS exposure through dialyzer use during hemodialysis. Here, we report the bisphenol levels in extractables and leachables obtained from eight dialyzers currently on the market, including high-flux and medium cut-off membranes. A targeted liquid chromatography-mass spectrometry strategy utilizing stable isotope-labeled internal standards provided reliable data for quantitation with the standard addition method. BPA ranging from 0.43 to 32.82 µg/device and BPS ranging from 0.02 to 2.51 µg/device were detected in dialyzers made with BPA- and BPS-containing materials, except for the novel FX CorAL 120 dialyzer. BPA and BPS were also not detected in bloodline controls and cellulose-based membranes. Based on the currently established tolerable intake (6 µg/kg/day), the resulting margin of safety indicates that adverse effects are unlikely to occur in hemodialysis patients exposed to BPA and BPS quantified herein. With increasing availability of new data and information about the toxicity of BPA and BPS, the patient safety limits of BPA and BPS in those dialyzers may need a re-evaluation in the future.


Asunto(s)
Riñones Artificiales , Diálisis Renal , Fenoles/análisis
9.
Nat Rev Nephrol ; 19(8): 481-490, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37277461

RESUMEN

Haemodialysis is life sustaining but expensive, provides limited removal of uraemic solutes, is associated with poor patient quality of life and has a large carbon footprint. Innovative dialysis technologies such as portable, wearable and implantable artificial kidney systems are being developed with the aim of addressing these issues and improving patient care. An important challenge for these technologies is the need for continuous regeneration of a small volume of dialysate. Dialysate recycling systems based on sorbents have great potential for such regeneration. Novel dialysis membranes composed of polymeric or inorganic materials are being developed to improve the removal of a broad range of uraemic toxins, with low levels of membrane fouling compared with currently available synthetic membranes. To achieve more complete therapy and provide important biological functions, these novel membranes could be combined with bioartificial kidneys, which consist of artificial membranes combined with kidney cells. Implementation of these systems will require robust cell sourcing; cell culture facilities annexed to dialysis centres; large-scale, low-cost production; and quality control measures. These challenges are not trivial, and global initiatives involving all relevant stakeholders, including academics, industrialists, medical professionals and patients with kidney disease, are required to achieve important technological breakthroughs.


Asunto(s)
Riñones Artificiales , Dispositivos Electrónicos Vestibles , Humanos , Calidad de Vida , Diálisis Renal , Soluciones para Diálisis
10.
Pediatr Nephrol ; 38(11): 3863-3866, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37099185

RESUMEN

BACKGROUND: From 2006 to 2020, 24% of children starting haemodialysis in France weighed < 20 kg. Most new-generation long-term haemodialysis machines do not propose paediatric lines anymore but Fresenius has validated two devices for use in children above 10 kg. Our aim was to compare the daily use of these two devices in children < 20 kg. METHODS: Retrospective single-center evaluation of daily practice with Fresenius 6008® machines, and low-volume paediatric sets (83 mL), as compared to 5008® machines with paediatric lines (108 mL). Each child was treated randomly with both generators. RESULTS: A total of 102 online haemodiafiltration sessions were performed over 4 weeks in five children (median body weight 12.0 [range 11.5-17.0] kg). Arterial aspiration and venous pressures were maintained respectively over - 200 mmHg and under 200 mmHg. For all children, blood flow and volume treated per session were lower with 6008® vs. 5008® (p < 0.001), median difference between the two devices being 21%. In the four children treated in post-dilution mode, substituted volume was lower with 6008® (p < 0.001, median difference: 21%). Effective dialysis time was not different between the two generators; however, the difference between total duration of session and dialysis effective time was slightly higher (p < 0.05) with 6008® for three patients, due to treatment interruptions. CONCLUSION: These results suggest that children between 11 and 17 kg should be treated with paediatric lines on 5008® if possible. They advocate for modification of the 6008 paediatric set to decrease resistance to blood flow. The possibility to use 6008® with paediatric lines in children below 10 kg deserves further studies.


Asunto(s)
Hemodiafiltración , Riñones Artificiales , Niño , Humanos , Hemodiafiltración/métodos , Hemodinámica , Diálisis Renal/métodos , Estudios Retrospectivos
13.
Semin Dial ; 36(3): 184-192, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36461085

RESUMEN

Prescribing dialysate sodium is the responsibility of the physician, but there are currently no clear guidelines for this prescription. Furthermore, there is quite frequently a significant difference between prescribed and measured dialysate sodium. Several arguments, both theoretical and experimental, suggest that dialysate sodium should be adjusted individually in such a way as to result in a decreasing sodium profile that takes into account the patient's predialytic natremia. The generalization in clinical routine of this strategy requires the integration into the hemodialysis monitor of software making the machine capable to automatically adjust the dialysate sodium at each session. The only three such softwares that have been integrated into hemodialysis machines for routine clinical use are discussed. All three work with conductivity measurements as a surrogate for sodium concentrations. Although there are only a few publications on the use of these softwares in clinical practice, they appear to result in improved intradialytic tolerance to the dialysis treatment, better control of hypertension, and reduced thirst, leading to decreased interdialytic weight gain.


Asunto(s)
Hipertensión , Riñones Artificiales , Humanos , Diálisis Renal/efectos adversos , Soluciones para Diálisis , Sodio
14.
Artif Organs ; 47(4): 649-666, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36129158

RESUMEN

BACKGROUND: Chronic kidney disease (CKD) is a major cause of early death worldwide. By 2030, 14.5 million people will have end-stage kidney disease (ESKD, or CKD stage 5), yet only 5.4 million will receive kidney replacement therapy (KRT) due to economic, social, and political factors. Even for those who are offered KRT by various means of dialysis, the life expectancy remains far too low. OBSERVATION: Researchers from different fields of artificial organs collaborate to overcome the challenges of creating products such as Wearable and/or Implantable Artificial Kidneys capable of providing long-term effective physiologic kidney functions such as removal of uremic toxins, electrolyte homeostasis, and fluid regulation. A focus should be to develop easily accessible, safe, and inexpensive KRT options that enable a good quality of life and will also be available for patients in less-developed regions of the world. CONCLUSIONS: Hence, it is required to discuss some of the limits and burdens of transplantation and different techniques of dialysis, including those performed at home. Furthermore, hurdles must be considered and overcome to develop wearable and implantable artificial kidney devices that can help to improve the quality of life and life expectancy of patients with CKD.


Asunto(s)
Fallo Renal Crónico , Riñones Artificiales , Insuficiencia Renal Crónica , Dispositivos Electrónicos Vestibles , Humanos , Calidad de Vida , Fallo Renal Crónico/cirugía , Insuficiencia Renal Crónica/terapia
15.
Zhongguo Yi Liao Qi Xie Za Zhi ; 46(4): 417-421, 2022 Jul 30.
Artículo en Chino | MEDLINE | ID: mdl-35929158

RESUMEN

With the rapid development of my country's hemodialysis industry, the application of hemodialysis machines has become more and more extensive, but at the same time, the quality control technology of hemodialysis machines is not perfect. Especially for a wide range of leachable substances in dialyzers, there are few studies and detection methods. This study first briefly describes the development of hemodialyzers, and then expounds the common types of leachables, extraction methods, and chromatography and mass spectrometry conditions. It is summarized that the research plan of leachable substances is to determine the type first, then formulate the extraction plan, and then establish the detection method. Finally, we look forward to the research prospects of hemodialyzer leachables, and point out that with the deepening and extensive development of research, it can further promote the healthy development of the hemodialyzer industry.


Asunto(s)
Fallo Renal Crónico , Riñones Artificiales , Humanos , Fallo Renal Crónico/terapia , Diálisis Renal
16.
Int J Artif Organs ; 45(11): 889-897, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36036062

RESUMEN

Dialysis-induced changes in plasma sodium concentration may cause undesirable side effects. To prevent these, the sodium content in dialysis fluid has to be individualized based on the patient's plasma sodium concentration. In this paper, we describe a simple conductivity based method for measuring the plasma sodium concentration. The method is based on performing a bypass during which the residual volume on the dialysate side of the dialyzer at least partially adopts the sodium concentration on the blood side. The conductivity at dialysate outlet of the dialyzer after the end of bypass corresponds to the sodium concentration. We show that already 14 s of bypass are sufficient to subsequently measure a conductivity that correlates with the blood-side sodium concentration. Thus, the short bypass method allows a time saving of 88% compared to the long bypass of 120 s. In vitro experiments with bovine blood show that plasma sodium concentration can be non-invasively and time-efficiently measured during dialysis. Bland Altman analysis reveals a bias of 0.28 mmol/l and limits of agreement of -3.17 and 3.74 mmol/l for the long bypass. For the short bypass, bias is 0.09 mmol/l and limits are -3.90 and 4.08 mmol/l. Since the method presented is based on established conductivity cells, no additional sensors are required, so that the method could be easily implemented in dialysis machines. In future, performing a bypass at the beginning of a treatment may be used to adjust the composition of dialysis fluid individually for each patient.


Asunto(s)
Riñones Artificiales , Diálisis Renal , Animales , Bovinos , Soluciones para Diálisis , Humanos , Diálisis Renal/métodos , Sodio
17.
Artif Organs ; 46(6): 1192-1197, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35438199

RESUMEN

HemoCleanse collaborated with Dr. John Sherman and Union Carbide in the 1980s to develop a cation exchanger with high selectivity for potassium and ammonium, for use in a wearable artificial kidney. Synthetic zeolites had unexpected solubility in this application but by 2000, UOP (a sister company of Union Carbide) had developed zirconium cyclosilicate (SZC). HemoCleanse performed early animal studies of SZC as an oral sorbent. These showed remarkable binding characteristics. HemoCleanse then obtained the license for SZC for medical applications, helped to form ZS Pharma, and collaborated in further animal studies and clinical trials. AstraZeneca purchased ZS Pharma in 2015, and SZC (Lokelma®) has now become an effective treatment for hyperkalemia in patients with kidney failure and cardiac conditions.


Asunto(s)
Hiperpotasemia , Riñones Artificiales , Humanos , Hiperpotasemia/tratamiento farmacológico , Potasio/uso terapéutico , Resultado del Tratamiento , Circonio/uso terapéutico
18.
ACS Biomater Sci Eng ; 8(4): 1726-1734, 2022 04 11.
Artículo en Inglés | MEDLINE | ID: mdl-35302761

RESUMEN

Acute kidney injury (AKI) has emerged as a major public health problem affecting millions of people worldwide without specific and satisfactory therapies due to the lack of an effective delivery approach. In the past few decades, hydrogels present infinite potential in localized drug delivery, while their poor adhesion to moist tissue and isotropic diffusion character always restrict the therapeutic efficiency and may lead to unwanted side effects. Herein, we proposed a novel therapeutic strategy for AKI via a customizable artificial kidney capsule (AKC) together with a mesenchymal stem cell (MSC)-laden hydrogel. Specifically, an elastic capsule owning an inner chamber with the same size and shape as the kidney is designed and fabricated through three-dimensional (3D) modeling and printing, serving as an outer wrap for kidney and cell-laden hydrogels. According to the in vitro experiment, the excellent biocompatibility of gelatin-based hydrogel ensures viability and proliferation of MSCs. In vivo mice experiments proved that this concept of AKC-assisted kidney drug delivery could efficiently reduce epithelial cell apoptosis and minimize the damage of the renal tubular structure for mice suffering AKI. Such a strategy not only provides a promising alternative in the treatment of AKI but also offers a feasible and versatile approach for the repair and recovery of other organs.


Asunto(s)
Lesión Renal Aguda/terapia , Hidrogeles/uso terapéutico , Riñones Artificiales , Trasplante de Células Madre Mesenquimatosas , Células Madre Mesenquimatosas , Rabdomiólisis/complicaciones , Lesión Renal Aguda/etiología , Animales , Humanos , Hidrogeles/administración & dosificación , Hidrogeles/química , Trasplante de Células Madre Mesenquimatosas/métodos , Ratones , Impresión Tridimensional , Rabdomiólisis/tratamiento farmacológico
20.
Pediatr Nephrol ; 37(3): 667-675, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34414499

RESUMEN

BACKGROUND: The most severely ill neonates and infants with AKI who need kidney replacement therapy have had to rely upon peritoneal dialysis, or adaptations of veno-venous continuous kidney replacement therapy (CKRT) devices for adults. Data from the Prospective Pediatric CRRT (ppCRRT) registry observed children < 10 kg had a lower survival rate than children > 10 kg (44% vs. 64%, p < 0.001). A CKRT device designed specifically for small children could improve outcomes. The Cardio-Renal Pediatric Dialysis Emergency Machine (CARPEDIEM™) is specifically dedicated to providing CKRT for newborns and small infants. METHODS: We performed a retrospective cohort analysis comparing patient severity of illness and outcomes between the ppCRRT and CARPEDIEM registries, involving 6 Italian pediatric intensive care units. Thirty-eight subjects from the CARPEDIEM registry and 84 subjects from the ppCRRT registry < 10 kg were screened for comparison. We compared patient outcomes with a weight-matched cohort (< 5 kg) of 34 patients from the CARPEDIEM registry and 48 patients from the ppCRRT registry. RESULTS: The ppCRRT subjects had higher rates of vasoactive medication at CKRT initiation. Survival to CKRT termination was higher for CARPEDIEM subjects (33/34 vs. 21/48, p < 0.0001). Multivariable logistic regression showed that CARPEDIEM registry cohort was the only variable to retain an association with survival to CKRT discontinuation. CONCLUSIONS: We suggest children receiving CKRT using CARPEDIEM have excellent survival. Our data should be interpreted with caution given the retrospective comparison across two eras more than a decade apart.


Asunto(s)
Lesión Renal Aguda , Terapia de Reemplazo Renal Continuo , Riñones Artificiales , Lesión Renal Aguda/terapia , Adulto , Niño , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Estudios Prospectivos , Terapia de Reemplazo Renal , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS