Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Int J Occup Saf Ergon ; 29(2): 765-772, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35622373

RESUMEN

Objectives. This study aimed to perform content and construct validation of the questionnaire for detection of sick building syndrome for health-care workers in the Brazilian context; and to evaluate the length of employment in relation to the level of exposure to occupational risks that trigger occupational disease. Methods. This methodological and cross-sectional study consisted of validation of the questionnaire for detection of sick building syndrome for Brazil, and application of this to health workers. The questionnaire was validated through two axes: content and construct by contrasted groups. Results. The general index corresponded to 0.81, considering the instrument validated as to content. Fleiss' K index showed an inter-rater agreement of 68.59%, with a free margin of 0.53. Regarding the analysis by contrasted groups, there was a significant association with the two contrasted groups for time of work in the building and in the sector with some variables described as follows: age group, level of education, time of work in the position, satisfaction with the usual working hours, promotion of workers, etc. Conclusion. It is hoped that the validation of this questionnaire can contribute to a greater visibility of this pathology in the Brazilian worker's health scenario.


Asunto(s)
Síndrome del Edificio Enfermo , Humanos , Brasil , Estudios Transversales , Encuestas y Cuestionarios , Empleo , Reproducibilidad de los Resultados
2.
Bol. malariol. salud ambient ; 62(1): 47-54, jun, 2022. tab, ilus
Artículo en Español | LILACS, LIVECS | ID: biblio-1381292

RESUMEN

El síndrome del edificio enfermo, se refiere a un conjunto de síntomas generales en mucosa (ocular y/o respiratoria) y piel que presentan los ocupantes de edificaciones con calidad ambiental deficientes, exponiendo a sus ocupantes a factores de riesgos físicos, mecánicos, químicos, biológicos y psicosociales, que puede afectar negativamente la salud y productividad de las personas. Con el propósito de determinar la frecuencia de los síntomas de los ocupantes de una industria manufacturera del Perú, se realizó estudio transversal aplicándose a 237 trabajadores, estratificados por áreas laborales, el cuestionario sugerido por el Instituto Nacional de Higiene y Seguridad en el Trabajo, además de evaluar la condición ambiental mediante la determinación de bioaerosoles cultivables y contables. Los resultados mostraron prevalencia superior al 20% en síntomas como: sequedad en ojos y garganta, picor en garganta congestión nasal, dolor de cabeza y debilidad general. Se tomaron, cuantificaron y caracterizaron 164 muestras de bioaerosoles, los microrganismos encontrados con mayor porcentaje fueron, Aspergillus sp. 54,68% (68) en el área administrativa, mientras que en las áreas de producción y almacén predomino Penicillium sp. con 87,10% (108) y 62,21% (77) respectivamente. Otros géneros encontrados en mayor porcentajes, en las tres áreas fueron: Trichoderma, Acremonium, Monilia, Cladosporium, entre otros. Los hallazgos se correlacionan con lo reportado en diversas investigaciones, la presencia de mencionados hongos, sugiere que existe una inadecuada calidad ambiental y aunada a la prevalencia obtenida en cuanto a sintomatología, se puede clasificar la edificación objeto de estudio con el Síndrome del edificio enfermo(AU)


Sick building syndrome refers to a set of general mucosal (ocular and/or respiratory) and skin symptoms presented by occupants of buildings with poor environmental quality, exposing their occupants to physical, mechanical, chemical, biological and psychosocial, which can negatively affect the health and productivity of people. In order to determine the frequency of the symptoms of the occupants of a manufacturing industry in Peru, a cross-sectional study was carried out, applying to 237 workers, stratified by work areas, the questionnaire suggested by the National Institute of Hygiene and Safety at Work, in addition to to evaluate the environmental condition by determining cultivable and countable bioaerosols. The results showed a prevalence greater than 20% in symptoms such as: dry eyes and throat, itchy throat, nasal congestion, headache and general weakness. 164 samples of bioaerosols were taken, quantified and characterized, the microorganisms found with the highest percentage were Aspergillus sp. 54.68% (68) in the administrative area, while in the production and storage areas, Penicillium sp. with 87.10% (108) and 62.21% (77) respectively. Other genera found in higher percentages in the three areas were: Trichoderma, Acremonium, Monilia, Cladosporium, among others. The findings correlate with what has been reported in various investigations, the presence of these fungi suggests that there is an inadequate environmental quality and, together with the prevalence obtained in terms of symptoms, the building under study can be classified with the Sick Building Syndrome(AU)


Asunto(s)
Humanos , Masculino , Adulto , Persona de Mediana Edad , Estudios Transversales , Síndrome del Edificio Enfermo/etiología , Síndrome del Edificio Enfermo/epidemiología , Contaminación del Aire/efectos adversos , Aspergilosis Pulmonar/epidemiología , Perú/epidemiología , Asma , Rinitis , Trastornos de Cefalalgia , Otomicosis , Industria Manufacturera
3.
Bol. malariol. salud ambient ; 62(5): 960-967, 2022. tab
Artículo en Español | LILACS, LIVECS | ID: biblio-1426706

RESUMEN

En todo el mundo, los cambios climáticos y estilo de vida han resultado en un cambio de ambientes de aire libre a ambientes herméticos y energéticamente eficientes en el hogar y en los lugares de trabajo, donde las personas pasan parte sustancial de su tiempo. En esos entornos, el mantenimiento inadecuado de los aparatos de aire acondicionado, el diseño deficiente de edificio o de los hogares, y las actividades de sus ocupantes pueden dar lugar a condiciones de salud precaria, que pueden incluir enfermedades respiratorias. Bajo un estudio descriptivo, de cohorte transversal, se evaluaron 104 residencias familiares tipo apartamento con sistemas de aclimatización tipo Split en las habitaciones de descanso. Se obtuvieron resultados positivos para dermatofitos en 34 de las 104 muestras (33,65%), mientras que los hongos filamentosos y levaduras fueron 27 casos (25,96%). La concentración osciló entre 17 y 227 UFC/m3 y de 9 a 46 UFC/m3 para dermatofitos y para filamentosos y levaduras, respectivamente. Las especies de hongos dermatofitos aislados en el aire fueron Trichophyton rubrum y Trichophyton mentagrophytes, siendo el más frecuente fue el Trichophyton rubrum que apareció en el 73,52% de las muestras positivas, representamdo una frecuencia de ocurrencia de 24,04%; en ninguna de las muestras se observaron colonias mixtas con ambas especies a la vez. En el grupo de los no dermatofitos, el Penicillium spp. se presento en 10,58% de las muestras evaluadas, siendo el hongo mas prevalente de este grupo, con contajes que alcanzaron hasta 46 UFC/m3. Este grupo en los 27 positivos, se evidencio al menos dos especies de hongos y adicionalmente en 14 casos una levadura. Este estudio demostró que el no aplicar las medidas correctivas y sistema de limpieza de los aires acondiconados puede comprometer la salud de sus habitantes, especialmente por problemas respiratorios, por la presencia de hongos(AU)


Throughout the world, climate and lifestyle changes have resulted in a shift from outdoor environments to airtight and energy-efficient environments at home and in workplaces, where people spend a substantial part of their time. In these environments, inadequate maintenance of air conditioners, poor building or home design, and the activities of its occupants can lead to poor health conditions, which may include respiratory diseases. Under a descriptive, cross-sectional cohort study, 104 apartment-type family residences with acclimatization systems in Split-type rest rooms were evaluated. Positive results for dermatophytes were obtained in 34 of the 104 samples (33.65%), while filamentous fungi and yeasts were 27 cases (25.96%). The concentration ranged between 17 and 227 CFU/m3 and from 9 to 46 CFU/m3 for dermatophytes and for filamentous and yeasts, respectively. The species of dermatophyte fungi isolated in the air were Trichophyton rubrum and Trichophyton mentagrophytes, the most frequent being Trichophyton rubrum, which appeared in 73.52% of the positive samples, representing a frequency of occurrence of 24.04%; mixed colonies with both species at the same time were not observed in any of the samples. In the group of non-dermatophytes, Penicillium spp. it was present in 10.58% of the evaluated samples, being the most prevalent fungus of this group, with counts that reached up to 46 CFU/m3. This group in the 27 positives, evidenced at least two species of fungi and additionally in 14 cases a yeast. This study showed that not applying corrective measures and the air conditioning cleaning system can compromise the health of its inhabitants, especially due to respiratory problems, due to the presence of fungi


Asunto(s)
Monitoreo del Ambiente , Síndrome del Edificio Enfermo , Aire Acondicionado , Estilo de Vida , Enfermedades Pulmonares Fúngicas , Aspergilosis , Aspergillus fumigatus , Cambio Climático , Mantenimiento de Equipo , Hongos
4.
Rev. cuba. enferm ; 36(3): e3404, tab
Artículo en Portugués | CUMED, LILACS, BDENF - Enfermería | ID: biblio-1280272

RESUMEN

Introdução: A mensuração de fenômenos em Saúde possui implicação na detecção precoce de agravos. A Saúde do Trabalhador no Brasil e seu potencial para internacionalização facilitam o uso de materiais estrangeiros de mensuração de fenômenos. Objetivo: Adaptar transculturalmente o Cuestionario para Detección del Síndrome del Edifício Enfermo para o contexto de trabalhadores de saúde brasileiros. Métodos: Estudo metodológico, transversal, quantitativo, a partir das etapas: 2 traduções iniciais, 1 síntese das traduções, 2 retrotraduções, comitê de especialistas e pré-teste realizado com 37 trabalhadores de saúde de um hospital. As variáveis numéricas foram abordadas por análise estatística descritiva univariada, utilizando-se tabelas de frequência para sumarizar os dados. Resultados: O instrumento foi traduzido e submetido às etapas de adaptação transcultural, e sofreu alterações de itens, além de adequações: semântica, idiomática, cultural e conceitual. Os trabalhadores participantes do pré-teste também contribuíram com modificações no questionário e eram em sua maioria técnicos de enfermagem, enfermeiros e médicos; referiram preocupação com sua saúde, e muitos apresentaram queixas de adoecimento físico relacionado ao trabalho. Após as modificações de itens e substituições de termos, foi obtida uma versão adaptada. O pré-teste possibilitou a observação de problemas frequentes como trabalho em turnos prolongados e a pouca oportunidade de tomada de decisão do trabalhador. Conclusão: O questionário adaptado para o português do Brasil está adequado ao contexto dos trabalhadores de saúde brasileiros e constitui recurso a detecção precoce da Síndrome do Edifício Doente na visão contextual do trabalho(AU)


Introducción: La medición de los fenómenos de salud tiene implicaciones para la detección temprana de enfermedades. La salud laboral en Brasil y su potencial de internacionalización facilitan el uso de materiales extraños para medir fenómenos. Objetivo: Adaptar transculturalmente el cuestionario para detección del síndrome de edificio enfermo en el contexto de los trabajadores de salud brasileños. Métodos: Estudio metodológico, transversal y cuantitativo, a partir de los pasos: 2 traducciones iniciales, 1 síntesis de traducciones, 2 traducciones posteriores, comité de expertos y prueba previa realizada con 37 trabajadores de salud de un hospital. Las variables numéricas se abordaron por análisis estadístico descriptivo univariado, utilizando tablas de frecuencia para resumir los datos. Resultados: El instrumento fue traducido y sometido a las etapas de adaptación intercultural, y sufrió cambios en los ítems, así como ajustes: semántico, idiomático, cultural y conceptual. Los trabajadores que participaron en la prueba previa también contribuyeron a las modificaciones en el cuestionario y fueron en su mayoría técnicos de enfermería, enfermeras y médicos; informaron preocupación por su salud y muchos se quejaron de enfermedades físicas relacionadas con el trabajo. Después de las modificaciones de los ítems y las sustituciones de términos, se obtuvo una versión adaptada. La prueba previa permitió observar problemas frecuentes, como trabajar turnos largos y la poca oportunidad para que el trabajador tomara decisiones. Conclusiones: El cuestionario adaptado al portugués brasileño es apropiado para el contexto de los trabajadores de salud brasileños y es una característica de detección temprana del síndrome del edificio enfermo en la vista del trabajo(AU)


Introduction: The measurement of health phenomena has implications concerning early detection of diseases. Occupational health in Brazil and its potential for internationalization facilitate the use of foreign materials to measure phenomena. Objective: To adapt, cross-culturally, the questionnaire for the detection of sick-building syndrome in the setting of Brazilian health workers. Methods: Methodological, cross-sectional and quantitative study based on the following steps: two initial translations, one synthesis of translations, two subsequent translations, a committee of experts, and a preliminary test carried out with 37 health workers from a hospital. The numerical variables were addressed by univariate descriptive statistical analysis, using frequency tables to summarize the data. Results: The instrument was translated and subjected to the intercultural adaptation stages, and underwent changes in the items, as well as adjustments of the following types: semantic, idiomatic, cultural and conceptual. The workers who participated in the pre-test also contributed to the modifications in the questionnaire and were mostly nursing technicians, nurses and doctors; they reported concern for their health, and many complained over work-related physical illnesses. After the modifications of the items and the substitutions of terms, an adapted version was obtained. The pre-test revealed frequent problems, such as working long shifts and little opportunity for the worker to make decisions. Conclusions: The questionnaire adapted to Brazilian Portuguese is appropriate for the setting of Brazilian health workers, and is a feature of early detection of sick-building syndrome in the workplace(AU)


Asunto(s)
Humanos , Encuestas y Cuestionarios , Salud Laboral , Síndrome del Edificio Enfermo/diagnóstico , Adaptación a Desastres , Horario de Trabajo por Turnos , Estudios Transversales
5.
Rev. cuba. enferm ; 36(2): e3284, abr.-jul.2020. tab, graf
Artículo en Español | CUMED, LILACS, BDENF - Enfermería | ID: biblio-1280262

RESUMEN

Introducción: La salud ocupacional involucra importantes líneas de debate. La enfermedad ocupacional ve el ejercicio del trabajo y el ambiente de trabajo como causas de la enfermedad de los trabajadores, como es el caso del síndrome del edificio enfermo. Objetivo: Discutir, en base a la literatura científica, el síndrome del edificio enfermo en el contexto de los trabajadores de la salud. Métodos: Revisión integradora realizada en abril de 2019. Se usaron cuatro bases de datos en las cuales se obtuvieron 37 artículos inicialmente. No se aplicaron los criterios de delimitación temporal o idiomática. Después de leer por completo se dejaron 10 estudios primarios que se trataron más adelante. Toda la selección y el análisis siguieron un diagrama de flujo y la estrategia de PRISMA. Conclusión: Se encontró poca producción sobre el síndrome del edificio enfermo enfocado en el contexto de los trabajadores de la salud, lo que dificulta la obtención de estudios actuales que aborden el problema. Sin embargo, según lo que se ha revisado, los factores causales van desde fallas en los sistemas de ventilación y sus cualidades hasta el problema de la sobrecarga de trabajo y los entornos con microorganismos. Los síntomas son diversos y se caracterizan principalmente por problemas relacionados con las vías respiratorias, la piel y el tracto psicológico. Las actividades de intervención involucran el desempeño de profesionales dirigidos a unidades de salud ocupacional, el uso de instrumentos para detectar riesgos de exposición y cambios en los hábitos estructurales(AU)


Introduction: Occupational health involves important lines of debate. Occupational disease sees working and the work environment as causes of workers' disease, as is the case of sick building syndrome. Objective: To discuss, based on the scientific literature, the sick building syndrome in the setting of health workers. Methods: Integrative review carried out in April 2019. Four databases were used, in which 37 articles were initially obtained. The criteria of time or language delimitation were not applied. After reading the whole information, 10 primary studies were chosen, which were discussed later. All the choosing and the analysis followed a flow chart and the strategy of PRISMA. Conclusion: Little production was found about sick building syndrome focused on the setting of health workers, making it difficult to obtain current studies that address the problem. However, based on what has been reviewed, the causal factors range from failure of ventilation systems and their qualities to the problem of work overload and environments with microorganisms. The symptoms are diverse and characterized mainly by problems related to the respiratory tract, the skin, and the psychological aspect. Intervention activities involve professional performance targeted to occupational health units, the use of instruments to detect exposure risks, and changes in structural habits(AU)


Asunto(s)
Humanos , /métodos , Salud Laboral , Personal de Salud , Síndrome del Edificio Enfermo/etiología , Literatura de Revisión como Asunto , Bases de Datos Bibliográficas
6.
Cien Saude Colet ; 16(8): 3583-90, 2011 Aug.
Artículo en Portugués | MEDLINE | ID: mdl-21860958

RESUMEN

Indoor Air Quality (IAQ) emerged as a science from the 1970s onwards with the energy crisis and the subsequent construction of sealed buildings (without natural ventilation). This mainly occurred in developed countries and it soon came to public attention that lower levels of air exchange in these environments was the main culprit for the increase in concentration of indoor air pollutants. It is common knowledge that ventilation is one of the principal factors that interfere with air quality in indoor environments and that the occupants contribute to the pollution of these environments with their activities. Furthermore, poor indoor air quality is associated with some diseases (cough, rhinitis, allergy, etc.) and with Sick Building Syndrome (SBS). For sampling of the indoor contaminants there are several methodologies, available including passive monitoring systems, active and automatic systems. To ensure a healthy indoor environment, the application of specific legislation needs to be reconciled with research and fostering awareness among the occupants of such buildings. This survey seeks to identify the different contaminants found in internal environments, their effects on human health and the methodologies available for sampling them.


Asunto(s)
Contaminación del Aire Interior/efectos adversos , Síndrome del Edificio Enfermo/etiología , Humanos
7.
Ciênc. Saúde Colet. (Impr.) ; Ciênc. Saúde Colet. (Impr.);16(8): 3583-3590, ago. 2011. tab
Artículo en Portugués | LILACS | ID: lil-595947

RESUMEN

A Qualidade do Ar Interno (QAI) surgiu como ciência a partir da década de 70 com a crise energética e a consequente construção dos edifícios selados (desprovidos de ventilação natural), principalmente nos países desenvolvidos, e se destacou após a descoberta de que a diminuição das taxas de troca de ar nesses ambientes era a grande responsável pelo aumento da concentração de poluentes no ar interno. Admite-se que a ventilação seja um dos principais fatores que interferem na qualidade do ar interno e que os próprios ocupantes dos edifícios contribuem substancialmente com a poluição destes ambientes através de suas atividades. Sabe-se ainda que a má qualidade do ar interno está associada a doenças (como tosse, rinite, alergia, etc.) e à Síndrome dos Edifícios Doentes (SED). Para amostragem de substâncias gasosas no ar de ambientes internos dispõe-se de diversas metodologias, sendo as principais: sistemas passivos de monitoramento, sistemas ativos e automáticos. Para a efetiva promoção de um ambiente saudável, deve-se conciliar a aplicação de legislações específicas com pesquisas e conscientização dos ocupantes dos edifícios. Essa revisão objetiva relacionar os diferentes contaminantes encontrados em ambientes internos, seus efeitos à saúde humana e suas metodologias de amostragem.


Indoor Air Quality (IAQ) emerged as a science from the 1970s onwards with the energy crisis and the subsequent construction of sealed buildings (without natural ventilation). This mainly occurred in developed countries and it soon came to public attention that lower levels of air exchange in these environments was the main culprit for the increase in concentration of indoor air pollutants. It is common knowledge that ventilation is one of the principal factors that interfere with air quality in indoor environments and that the occupants contribute to the pollution of these environments with their activities. Furthermore, poor indoor air quality is associated with some diseases (cough, rhinitis, allergy, etc.) and with Sick Building Syndrome (SBS). For sampling of the indoor contaminants there are several methodologies, available including passive monitoring systems, active and automatic systems. To ensure a healthy indoor environment, the application of specific legislation needs to be reconciled with research and fostering awareness among the occupants of such buildings. This survey seeks to identify the different contaminants found in internal environments, their effects on human health and the methodologies available for sampling them.


Asunto(s)
Humanos , Contaminación del Aire Interior/efectos adversos , Síndrome del Edificio Enfermo/etiología
8.
Ingenieria sanitaria y ambiental (Buenos Aires) ; (72): 80-82, ene.-feb. 2004. Ilus
Artículo en Español | BINACIS | ID: bin-139795

RESUMEN

El síndrome del edificio enfermo es un fenómeno relativamente reciente y reconocido internacionalmente. Los problemas derivados de este síndrome pueden aumentar debido a un diseño y mantenimiento inapropiado del sistema de ventilación y de aire acondicionado, equipamiento de oficina, amoblamiento, suministro y operaciones dentro del edificio


Asunto(s)
Vivienda , Contaminación del Aire , Síndrome del Edificio Enfermo
9.
Buenos Aires; ene.-feb. 2004. ilus.(Ingenieria sanitaria y ambiental, 72).
Monografía en Español | BINACIS | ID: biblio-1221404

RESUMEN

El síndrome del edificio enfermo es un fenómeno relativamente reciente y reconocido internacionalmente. Los problemas derivados de este síndrome pueden aumentar debido a un diseño y mantenimiento inapropiado del sistema de ventilación y de aire acondicionado, equipamiento de oficina, amoblamiento, suministro y operaciones dentro del edificio


Asunto(s)
Vivienda , Contaminación del Aire , Síndrome del Edificio Enfermo
10.
Cad Saude Publica ; 19(5): 1389-97, 2003.
Artículo en Portugués | MEDLINE | ID: mdl-14666220

RESUMEN

Air quality in industrial environments has been studied since the second half of the 20th century. Well-documented results show that exposure to chemical pollutants through their consumption, production, and storage can damage workers' health. New research focusing on non-industrial environments has shown unexpected correlations between air quality and health effects. Artificial ventilation systems have been related to health-related complaints and a high rate of absenteeism. Symptoms related to air quality in non-industrial environments are recognized by the World Health Organization and encompassed under the so-called sick building syndrome (SBS). In Brazil there are few studies comparing indoor air quality and health. The present study is intended to map the studies already conducted in Brazil in order to encourage further research in this area, due to its importance for public health.


Asunto(s)
Contaminación del Aire Interior/efectos adversos , Exposición Profesional/efectos adversos , Síndrome del Edificio Enfermo/etiología , Aire Acondicionado/efectos adversos , Contaminación del Aire Interior/economía , Contaminación del Aire Interior/legislación & jurisprudencia , Brasil/epidemiología , Humanos , Industrias , Exposición Profesional/economía , Exposición Profesional/legislación & jurisprudencia , Síndrome del Edificio Enfermo/diagnóstico , Síndrome del Edificio Enfermo/epidemiología , Lugar de Trabajo
12.
Rev. ciênc. farm ; 22(1): 31-39, 2001. tab
Artículo en Portugués | LILACS | ID: lil-318747

RESUMEN

Este trabalho objetivou conhecer a concentraçäo microbiana e a influência de alguns fatores ambientais na dispersäo de bioaerossóis em cômodos específicos, de uso restrito e público, do Prédio Tradicional da Faculdade de Ciências Farmacêuticas, onde situa o Departamento de Análises Clínicas, Farmácia Escola e Unidade Auxiliar. As amostragens foram realizadas utilizando-se o MAS-100, durante 2 períodos do ano, em 15 cômodos, sendo 5 laboratórios didáticos, 5 laboratórios de rotina e 5 salas de atendimento ao público. Os ambientes foram analisados em relaçäo ao tipo de climatizaçäo (natural ou artificial) e ao número de ocupantes. O tipo de climatizaçäo demonstrou näo influenciar no número de unidades formadoras de colônia por metro cúbico de ar dos diferentes ambientes. Diferenças significativas foram observadas em ambientes onde circulavam menos de 9 e 9 ou mais pessoas, independentemente do tipo de atividade desenvolvida. O fato de os próprios ocupantes serem as fontes mais prováveis de bioaerossóis em ambientes interiores estimula a instalaçäo de equipamentos eficientes que promovam a filtraçäo e renovaçäo do ar, diluindo partículas originadas dentro deles, principalmente naqueles onde há maior fluxo de indivíduos.


Asunto(s)
Humanos , Aerosoles/efectos adversos , Contaminantes Atmosféricos , Contaminación del Aire Interior/análisis , Recuento de Colonia Microbiana , Sector Público , Síndrome del Edificio Enfermo
13.
Arch Environ Health ; 55(4): 279-83, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-11005434

RESUMEN

In this questionnaire study, the authors compared the prevalence of certain symptoms and signs associated with Sick Building Syndrome and perceptions relative to environmental discomfort of employees in a central-air-conditioned dropping center and in natural-ventilation commercial shops located on the streets of Niteroi, Rio de Janeiro, Brazil. There was a statistically significant higher prevalence of symptoms (e.g., water and itching of eyes, sore throat, nose irritation, difficulty breathing, skin irritation, sneezing) that were characteristic of Sick Building Syndrome in the air-conditioned building than in the naturally ventilated stores. The results indicated that there exists a continuing need for further research in Brazilian work environments.


Asunto(s)
Exposición Profesional/efectos adversos , Síndrome del Edificio Enfermo/epidemiología , Ventilación/métodos , Adulto , Aire Acondicionado/efectos adversos , Brasil/epidemiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Exposición Profesional/análisis , Prevalencia , Síndrome del Edificio Enfermo/etiología , Síndrome del Edificio Enfermo/fisiopatología , Encuestas y Cuestionarios
14.
Gerencia ambiental ; 7(64): 329-30,332,334, Jun. 2000. ilus
Artículo en Español | BINACIS | ID: bin-141062

RESUMEN

La Legionella pneumophilla es una bacteria que produce una neumonía infecciosa y que puede encontrarse en sistemas de aire acondicionado, torres de refrigeración, condensadores evaporativos y humectadores. En este informe se detalla, entre otras cosas, cómo prevenir esta infección que tiene una vinculación directa con el síndrome del edificio enfermo


Asunto(s)
Síndrome del Edificio Enfermo , Infecciones Bacterianas
15.
Buenos Aires; Jun. 2000. ilus.(Gerenc. ambient., 7, 64).
Monografía en Español | BINACIS | ID: biblio-1222038

RESUMEN

La Legionella pneumophilla es una bacteria que produce una neumonía infecciosa y que puede encontrarse en sistemas de aire acondicionado, torres de refrigeración, condensadores evaporativos y humectadores. En este informe se detalla, entre otras cosas, cómo prevenir esta infección que tiene una vinculación directa con el síndrome del edificio enfermo


Asunto(s)
Infecciones Bacterianas , Síndrome del Edificio Enfermo
16.
In. Fernandes, Antonio Tadeu; Fernandes, Maria Olívia Vaz; Ribeiro Filho, Nelson; Graziano, Kazuko Uchikawa; Cavalcante, Nilton José Fernandes; Lacerda, Rúbia Aparecida. Infecçäo hospitalar e suas interfaces na área da saúde. Säo Paulo, Atheneu, 2000. p.1307-22, ilus, tab, graf.
Monografía en Portugués | LILACS, Sec. Est. Saúde SP | ID: lil-268095
17.
Rev. Asoc. Colomb. Alerg. Inmunol ; 8(4): 7-14, dic. 1999. tab, graf
Artículo en Español | LILACS | ID: lil-346721

RESUMEN

Objetivo: Determinar la prevalencia de síntomas alérgicos, respiratorios y neurológicos en trabajadores de un edificio de oficinas; asociar la prevalencia de los diferentes síntomas en función de la edad, el sexo, localización, frecuencia de presentación en la semana, antecedentes personales de rinitis, asma, alergias y ausentismo laboral, para compararlos con estudios realizados en otros países. Material y métodos: El estudio se realizó en Medellín; se seleccionó de forma aleatoria una muestra representativa de trabajadores, según la densidad de población en cada piso, expuestos a aire acondicionado central, en un edificio de trece pisos y un sótano, con una población total de 1.920 trabajadores. Se calculó la muestra teniendo en cuenta un nivel de confianza del 95 por ciento y un margen de error máximo del 5 por ciento. Se tuvo en cuenta la prevalencia de estos síntomas, en diferentes series de la literatura; previamente estandarizado con prueba piloto se aplicó el cuestionario entre octubre de 1996 y julio de 1997, por médicos y enfermeras adiestrados para tal fin. Resultados; Se aplicó el cuestionario a 350 trabajadores, 88(25.1 por ciento) hombres y 262 (74.9 por ciento) mujeres, la mayoría de ellos, 268 (76.6 por ciento), entre 30 y 49 años, presentaron algún síntoma 323 (92.3 por ciento); síntomas alérgicos como carraspera, estornudos, prurito nasal, la mayoría de ellos (62.6 por ciento, 57.1 por ciento, 50.0 por ciento respectivamente); síntomas neurológicos tales como cefalea y mareo, 189 (54.0 por ciento); síntomas respiratorios tales como tos, 131 (37.4 por ciento) y respiración corta 95 (27.1 por ciento). Los síntomas se presentaron principalmente el primer día de la semana, 323 (92.3 por ciento); se asociaron con antecedentes personales de rinitis, asma y alergias 111 personas (31.8 por ciento). 118 (33.7 por ciento) eran fumadores activos; 297 (84.9 por ciento) dijeron haber tenido al menos un episodio gripal en el último año y 97 (27.7 por ciento) fueron incapacitados por este problema...


Asunto(s)
Hipersensibilidad , Síndrome del Edificio Enfermo/epidemiología , Síndrome del Edificio Enfermo/inmunología , Condiciones de Trabajo
20.
s.l; s.n; 1997. 8 p.
No convencional en Portugués | LILACS | ID: lil-198750

RESUMEN

Aborda as condiçöes físicas dos ambientes internos que podem ter a sua qualidade alterada pela presença de gases e partículas estranhos à sua composiçäo normal, assim como, as outras condiçöes internas, como ventilaçäo, ruído, iluminaçäo e condiçöes ergonômicas, podem levar aos diversos sintomas apresentados por ocupantes de edificaçöes näo adequadamente projetadas ou utilizadas ou mantidas inadequadamente conhecido como "síndrome dos edifícios doentes"


Asunto(s)
Síndrome del Edificio Enfermo , Ventilación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA