Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Intervalo de año de publicación
1.
Chem Biol Interact ; 345: 109564, 2021 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-34161785

RESUMEN

Suppressive effect of bis (3-amino-2-pyridine) diselenide (BAPD) on psychiatric disorders - atopic dermatitis (AD) comorbidity in mice was investigated. To sensitize the animals, 2,4-dinitrochlorobenzene (DNCB) was applied to their dorsal skin on days 1-3. Mice were challenged with DNCB on their ears and dorsal skin on days 14, 17, 20, 23, 26, and 29. BAPD and Dexamethasone were administered to the animals, from days 14-29, and skin severity scores and behavioral tests were determined. Oxidative stress and inflammatory parameters were evaluated on the dorsal skin of mice. Na+, K+-ATPase activity and corticosterone levels were determined in hippocampus/cerebral cortex and plasma of mice, respectively. BAPD improved cutaneous damage, scratching behavior, inflammatory and oxidative stress markers. BAPD showed anxiolytic- and antidepressant-like effects and restored Na+, K+-ATPase activity and corticosterone levels. The present study was performed using female mice due the susceptibility for this disease. But, the evaluation of AD model in male mice would help to verify whether the male gender has the same predisposition to present this pathology. Our data demonstrated the suppressive effect of BAPD on psychiatric disorders - AD comorbidity by regulating inflammatory and oxidative status in mice.


Asunto(s)
Dermatitis Atópica/tratamiento farmacológico , Dermatitis Atópica/epidemiología , Trastornos Mentales/tratamiento farmacológico , Trastornos Mentales/epidemiología , Siloxanos/farmacología , Animales , Conducta Animal/efectos de los fármacos , Corteza Cerebral/efectos de los fármacos , Corteza Cerebral/metabolismo , Comorbilidad , Corticosterona/sangre , Corticosterona/metabolismo , Dermatitis Atópica/complicaciones , Dermatitis Atópica/metabolismo , Femenino , Hipocampo/efectos de los fármacos , Hipocampo/metabolismo , Inflamación/complicaciones , Trastornos Mentales/complicaciones , Trastornos Mentales/metabolismo , Ratones , Oxidación-Reducción/efectos de los fármacos , Estrés Oxidativo/efectos de los fármacos , Siloxanos/uso terapéutico
2.
Colloids Surf B Biointerfaces ; 164: 144-154, 2018 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-29413591

RESUMEN

Medical device-related infections represent a major healthcare complication, resulting in potential risks for the patient. Antimicrobial materials comprise an attractive strategy against bacterial colonization and biofilm proliferation. However, in most cases these materials are only bacteriostatic or bactericidal, and consequently they must be used in combination with other antimicrobials in order to reach the eradication condition (no viable microorganisms). In this study, a straightforward and robust antibacterial coating based on Phosphotungstate Ormosil doped with core-shell (SiO2@TiO2) was developed using sol-gel process, chemical tempering, and Ag nanoparticle photoassisted synthesis (POrs-CS-Ag). The coating was characterized by X-ray Fluorescence Spectroscopy (XRF), Field Emission Scanning Electron Microscopy (FE-SEM), Atomic Force Microscopy (AFM) and X-ray Photoelectron Microscopy (XPS). The silver free coating displays low antibacterial activity against Staphylococcus aureus and Pseudomonas aeruginosa, in opposition to the silver loaded ones, which are able to completely eradicate these strains. Moreover, the antimicrobial activity of these substrates remains high until three reutilization cycles, which make them a promising strategy to develop self-sterilizing materials, such as POrs-CS-Ag-impregnated fabric, POrs-CS-Ag coated indwelling metals and polymers, among other materials.


Asunto(s)
Luz , Nanopartículas del Metal/química , Siloxanos/farmacología , Plata/química , Esterilización , Antibacterianos/farmacología , Adhesión Bacteriana/efectos de los fármacos , Nanopartículas del Metal/ultraestructura , Pruebas de Sensibilidad Microbiana , Viabilidad Microbiana/efectos de los fármacos , Microscopía de Fuerza Atómica , Espectroscopía de Fotoelectrones , Pseudomonas aeruginosa/efectos de los fármacos , Pseudomonas aeruginosa/crecimiento & desarrollo , Espectrofotometría Ultravioleta , Staphylococcus aureus/efectos de los fármacos , Staphylococcus aureus/crecimiento & desarrollo , Propiedades de Superficie
3.
Dental Press J Orthod ; 22(4): 77-85, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28902253

RESUMEN

INTRODUCTION:: Plasma-polymerized film deposition was created to modify metallic orthodontic brackets surface properties in order to inhibit bacterial adhesion. METHODS:: Hexamethyldisiloxane (HMDSO) polymer films were deposited on conventional (n = 10) and self-ligating (n = 10) stainless steel orthodontic brackets using the Plasma-Enhanced Chemical Vapor Deposition (PECVD) radio frequency technique. The samples were divided into two groups according to the kind of bracket and two subgroups after surface treatment. Scanning Electron Microscopy (SEM) analysis was performed to assess the presence of bacterial adhesion over samples surfaces (slot and wings region) and film layer integrity. Surface roughness was assessed by Confocal Interferometry (CI) and surface wettability, by goniometry. For bacterial adhesion analysis, samples were exposed for 72 hours to a Streptococcus mutans solution for biofilm formation. The values obtained for surface roughness were analyzed using the Mann-Whitney test while biofilm adhesion were assessed by Kruskal-Wallis and SNK test. RESULTS:: Significant statistical differences (p< 0.05) for surface roughness and bacterial adhesion reduction were observed on conventional brackets after surface treatment and between conventional and self-ligating brackets; no significant statistical differences were observed between self-ligating groups (p> 0.05). CONCLUSION:: Plasma-polymerized film deposition was only effective on reducing surface roughness and bacterial adhesion in conventional brackets. It was also noted that conventional brackets showed lower biofilm adhesion than self-ligating brackets despite the absence of film.


Asunto(s)
Adhesión Bacteriana/efectos de los fármacos , Biopelículas/efectos de los fármacos , Soportes Ortodóncicos/microbiología , Siloxanos/farmacología , Streptococcus mutans/efectos de los fármacos , Streptococcus mutans/fisiología , Diseño de Aparato Ortodóncico , Plasma , Polimerizacion , Streptococcus mutans/aislamiento & purificación , Propiedades de Superficie
4.
Dental press j. orthod. (Impr.) ; 22(4): 77-85, July-Aug. 2017. tab, graf
Artículo en Inglés | LILACS | ID: biblio-891079

RESUMEN

ABSTRACT Introduction: Plasma-polymerized film deposition was created to modify metallic orthodontic brackets surface properties in order to inhibit bacterial adhesion. Methods: Hexamethyldisiloxane (HMDSO) polymer films were deposited on conventional (n = 10) and self-ligating (n = 10) stainless steel orthodontic brackets using the Plasma-Enhanced Chemical Vapor Deposition (PECVD) radio frequency technique. The samples were divided into two groups according to the kind of bracket and two subgroups after surface treatment. Scanning Electron Microscopy (SEM) analysis was performed to assess the presence of bacterial adhesion over samples surfaces (slot and wings region) and film layer integrity. Surface roughness was assessed by Confocal Interferometry (CI) and surface wettability, by goniometry. For bacterial adhesion analysis, samples were exposed for 72 hours to a Streptococcus mutans solution for biofilm formation. The values obtained for surface roughness were analyzed using the Mann-Whitney test while biofilm adhesion were assessed by Kruskal-Wallis and SNK test. Results: Significant statistical differences (p< 0.05) for surface roughness and bacterial adhesion reduction were observed on conventional brackets after surface treatment and between conventional and self-ligating brackets; no significant statistical differences were observed between self-ligating groups (p> 0.05). Conclusion: Plasma-polymerized film deposition was only effective on reducing surface roughness and bacterial adhesion in conventional brackets. It was also noted that conventional brackets showed lower biofilm adhesion than self-ligating brackets despite the absence of film.


RESUMO Introdução: a deposição de filme de polímero a plasma foi criada para modificar as propriedades de superfície dos braquetes ortodônticos metálicos, com o intuito de inibir a adesão bacteriana. Métodos: filmes finos de polímero de hexametildisiloxano (HMDSO) foram depositados em braquetes ortodônticos de aço inoxidável convencionais (n = 10) e autoligáveis (n = 10), utilizando a técnica de radiofrequência PECVD (Plasma-Enhanced Chemical Vapor Deposition). As amostras foram divididas em dois grupos, de acordo com o tipo de braquete, e dois subgrupos após o tratamento de superfície. A microscopia eletrônica de varredura (MEV) foi realizada para avaliar a presença de adesão bacteriana sobre as superfícies das amostras (região de ranhura horizontal e aletas) e a integridade da camada de filme. A Interferometria Confocal (CI) avaliou a rugosidade, e a molhabilidade superficial foi avaliada por goniometria. Para análise de adesão bacteriana, as amostras foram expostas durante 72 horas a uma solução de Streptococcus mutans, para formação de biofilme. Os valores obtidos para a rugosidade da superfície foram analisados pelo teste de Mann-Whitney, enquanto a adesão do biofilme foi avaliada pelos testes de Kruskal-Wallis e SNK. Resultados: observaram-se diferenças estatisticamente significativas (p <0,05) para a rugosidade superficial e redução da adesão bacteriana em braquetes convencionais após o tratamento da superfície, e entre braquetes convencionais e autoligáveis. Não foram observadas diferenças estatísticas significativas entre os grupos autoligáveis (p> 0,05). Conclusão: a deposição de polímero a plasma só foi efetiva na redução da rugosidade superficial e adesão bacteriana em braquetes convencionais. Observou-se, também, que os braquetes convencionais apresentaram menor adesão ao biofilme do que os braquetes autoligáveis, apesar da ausência de filme.


Asunto(s)
Siloxanos/farmacología , Streptococcus mutans/efectos de los fármacos , Streptococcus mutans/fisiología , Adhesión Bacteriana/efectos de los fármacos , Soportes Ortodóncicos/microbiología , Biopelículas/efectos de los fármacos , Plasma , Streptococcus mutans/aislamiento & purificación , Propiedades de Superficie , Diseño de Aparato Ortodóncico , Polimerizacion
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA