Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 285
Filtrar
1.
BMC Ophthalmol ; 24(1): 210, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38741065

RESUMEN

BACKGROUND: Parry-Romberg syndrome (PRS) is a rare progressive degenerative disorder of unknown etiology. Here we report a rare case of PRS combined with lens subluxation in Eye and ENT hospital of Fudan University, Shanghai. To our knowledge, it is the first reported case of PRS combined with lens subluxation that has been managed surgically with phacoemulsification and CTR placement and IOL implantation in Shanghai. CASE PRESENTATION: A 60-year-old woman was referred for "right visual blur for 2 years" and had persistent right facial paralysis of unknown etiology since the age 12. She had right facial muscle atrophy and paralysis. Eye examination also showed the right eyelid pseudoptosis, enophthalmos, age-related cataract combined with lens subluxation existed in the right eye. The patient was diagnosed as age-related cataract and lens subluxation in the right eye and progressive hemifacial atrophy (Parry-Romberg syndrome). We conducted a combined phacoemulsification, IOL and CTR implantation and pupilloplasty surgery for the patient under general anesthesia and the postoperative UCVA was 20/30 and remained for 1 year's follow up. CONCLUSIONS: Here we reported a rare case of PHA combined with lens subluxation in China. After appropriate eye surgery, the patient achieved satisfying vision result in the right eye.


Asunto(s)
Hemiatrofia Facial , Subluxación del Cristalino , Facoemulsificación , Humanos , Femenino , Hemiatrofia Facial/complicaciones , Hemiatrofia Facial/diagnóstico , Hemiatrofia Facial/cirugía , Persona de Mediana Edad , Subluxación del Cristalino/cirugía , Subluxación del Cristalino/diagnóstico , Subluxación del Cristalino/etiología , Implantación de Lentes Intraoculares , Agudeza Visual/fisiología
2.
Jpn J Ophthalmol ; 68(3): 200-205, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38587787

RESUMEN

PURPOSE: To evaluate the surgical outcomes of intrascleral intraocular lens (IOL) fixation using ab interno trabeculotomy (LOT) in patients with exfoliation glaucoma with lens subluxation. STUDY DESIGN: Retrospective case series. METHODS: Twenty eyes of 18 patients with exfoliation glaucoma and lens or IOL subluxations were included. Three success criteria were based on postoperative intraocular pressure (IOP) (A, ≤15 mmHg; B, ≤18 mmHg; C, ≤21 mmHg). The IOP, number of glaucoma medications, and visual acuity were compared before and after surgery. Success probability was analyzed using Kaplan-Meier survival curves. Cox proportional hazards' regression models were used to examine prognostic factors for surgical failure. RESULTS: The mean follow-up period was 23.4 ± 7.8 months. The mean IOP significantly decreased from 23.2 ± 6.8 mmHg preoperatively to 14.0 ± 4.4 mmHg at 1 year postoperative (P<0.001). Postoperative hyphema and vitreous hemorrhage were observed in seven and 15 eyes, respectively, and washout in the anterior chamber or vitreous cavity was performed in four eyes. Postoperative IOP spikes and hypotony were observed in four eyes each. Glaucoma reoperation was performed in two eyes. The success rates at 12 months were 65%, 85%, and 90% using criteria A, B, and C, respectively. The IOP at 1 month after surgery was a significant prognostic factor for surgical failure according to criterion A (hazard ratio: 1.08; P=0.034). CONCLUSION: Intrascleral IOL fixation combined with microhook LOT is a promising option in cases of exfoliation glaucoma with subluxated lens/IOL; however, the high rate of postoperative hyphema and vitreous hemorrhage should be noted.


Asunto(s)
Síndrome de Exfoliación , Presión Intraocular , Implantación de Lentes Intraoculares , Subluxación del Cristalino , Esclerótica , Trabeculectomía , Agudeza Visual , Humanos , Estudios Retrospectivos , Masculino , Femenino , Anciano , Esclerótica/cirugía , Síndrome de Exfoliación/fisiopatología , Síndrome de Exfoliación/cirugía , Síndrome de Exfoliación/complicaciones , Trabeculectomía/métodos , Presión Intraocular/fisiología , Agudeza Visual/fisiología , Subluxación del Cristalino/cirugía , Subluxación del Cristalino/fisiopatología , Subluxación del Cristalino/diagnóstico , Estudios de Seguimiento , Persona de Mediana Edad , Implantación de Lentes Intraoculares/métodos , Anciano de 80 o más Años , Lentes Intraoculares , Resultado del Tratamiento
3.
BMC Ophthalmol ; 24(1): 192, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38664661

RESUMEN

BACKGROUND: Ectopia lentis is the dislocation of the natural crystalline lens and usually presents in the setting of trauma or other systemic diseases. Herein, we describe a case of an otherwise healthy four-year-old boy with isolated ectopia lentis whose partial lens dislocation was captured on a smartphone by the patient's father several days prior. CASE PRESENTATION: A four-year-old boy with no past medical, developmental, or trauma history presented with bilateral partial anterior lens dislocation with pupillary block. Initial ophthalmic evaluation two months prior was notable for uncorrected visual acuity at 20/100 OD, 20/250 OS, bilateral iridodenesis, and partially dislocated lenses inferonasally OD and inferiorly OS on slit lamp. Genetic testing found no abnormalities. Ten months later, the patient developed sudden onset of left eye pain. A dislocated lens and temporarily dilated left pupil were captured on a smartphone by the patient's father. He was evaluated 3 days later after a second episode and found to have hand motion vision OS, a fixed 8 mm left pupil with the crystalline lens subluxed into the pupil space and accompanying intraocular pressure OS of 40 mmHg. The lens was surgically removed with a limited anterior vitrectomy. Four and a half years after surgery, visual acuity was 20/125 OS with aphakic correction. The right eye eventually underwent prophylactic lensectomy and was 20/30 in aphakic correction. CONCLUSIONS: This report presents a unique presentation of isolated ectopia lentis with anterior lens dislocation and pupillary block and illustrates the role of smartphone photography in assisting in the triage of eye emergencies.


Asunto(s)
Desplazamiento del Cristalino , Subluxación del Cristalino , Trastornos de la Pupila , Humanos , Desplazamiento del Cristalino/diagnóstico , Desplazamiento del Cristalino/cirugía , Masculino , Preescolar , Subluxación del Cristalino/diagnóstico , Subluxación del Cristalino/cirugía , Subluxación del Cristalino/etiología , Trastornos de la Pupila/diagnóstico , Trastornos de la Pupila/etiología , Agudeza Visual/fisiología , Vitrectomía/métodos
4.
Int Ophthalmol ; 44(1): 148, 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38502381

RESUMEN

PURPOSE: To investigate corneal biomechanical properties and its associations with the severity of lens dislocation in patients with Marfan syndrome. METHODS: A total of 30 patients with Marfan syndrome and 30 age-, sex- and axial length (AL)-matched controls were recruited. Corneal biomechanical parameters of both groups were measured by CorVis ST and were compared between groups. Potential associations between corneal biomechanical parameters and severity of lens dislocation were also investigated. RESULTS: Lower applanation 1 velocity (A1V) (0.13 ± 0.004 vs. 0.15 ± 0.003, P = 0.016), shorter applanation 2 time (A2T)(22.64 ± 0.11 vs. 22.94 ± 0.11, P = 0.013), longer peak distance (PD) (5.03 ± 0.07 vs. 4.81 ± 0.05, P = 0.008), longer radius (R) of highest concavity (7.44 ± 0.16 vs. 6.93 ± 0.14, P = 0.012), greater Ambrosio relational thickness horizontal (ARTh) (603 ± 20 vs. 498 ± 12, P < 0.001), and integrated radius (IR) (8.32 ± 0.25 vs. 8.95 ± 0.21, P = 0.033) were detected among Marfan eyes compared with controls (all P < 0.05). Marfan individuals with more severe lens dislocation tended to have increased stiffness parameter as longer A1T, slower A1V, shorter A2T, slower application 2 velocity (A2V), smaller PD and smaller Distance Amplitude (DA) (P < 0.05). CONCLUSION: Marfan patients were detected to have increased corneal stiffness compared with normal subjects. Corneal biomechanical parameters were significantly associated with the severity of lens dislocation in Marfan patients.


Asunto(s)
Subluxación del Cristalino , Síndrome de Marfan , Humanos , Síndrome de Marfan/complicaciones , Síndrome de Marfan/diagnóstico , Presión Intraocular , Fenómenos Biomecánicos , Córnea , Subluxación del Cristalino/diagnóstico , Subluxación del Cristalino/etiología , Tonometría Ocular
5.
Ophthalmic Res ; 67(1): 248-256, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38527448

RESUMEN

INTRODUCTION: This study aimed to determine the interchangeability of bilateral anterior chamber depth (ACD) in intraocular lens (IOL) power calculations for cataractous eyes and refractive outcomes using the unaffected fellow eye's ACD in subluxated crystalline lenses. METHODS: The predicted postoperative spherical equivalent (SE) calculated using the Kane formula with and without fellow eye's ACD in 202 cataract patients was compared. Refractive outcomes of the newer formulas (the Kane, Barrett Universal II [BUII], and Pearl-DGS formulas) with affected eye's ACD and with unaffected fellow eye's ACD were compared in 33 eyes with lens subluxation (the affected eye) undergoing in-the-bag IOL implantation. The SD of the prediction error (PE) was assessed using the heteroscedastic method. RESULTS: In 202 paired cataractous eyes, no marked ACD difference was found bilaterally; the predicted SE obtained without the fellow eye's ACD was comparable with that calculated with the fellow eye one (p = 0.90), with a mean absolute difference of 0.03 ± 0.03 D. With the affected eye AL, keratometry, and ACD, the median absolute error (MedAE) was 0.38-0.64 D, and the percentage of PE within ±0.50 D was 30.30-57.58%. The unaffected eye's ACD improved the results (MedAE, 0.35-0.49 D; the percentage of PE within ±0.50 D, 54.55-63.64%). The SDs of the BUII (0.82 D) and Pearl-DGS formulas (0.87 D) with the affected eye's ACD were significantly larger than those of the Kane and Pearl-DGS formulas (both 0.69 D) with the unaffected eye's ACD. CONCLUSION: Bilateral ACD was interchangeable in IOL power calculation for cataractous eyes when using the Kane formula. Unaffected eye's ACD in lieu of affected eye's ACD can enhance the accuracy of newer formulas in patients with unilateral subluxated lenses undergoing in-the-bag IOL implantation.


Asunto(s)
Cámara Anterior , Subluxación del Cristalino , Lentes Intraoculares , Refracción Ocular , Humanos , Masculino , Femenino , Anciano , Refracción Ocular/fisiología , Persona de Mediana Edad , Subluxación del Cristalino/cirugía , Subluxación del Cristalino/diagnóstico , Subluxación del Cristalino/fisiopatología , Adulto , Agudeza Visual , Estudios Retrospectivos , Óptica y Fotónica , Implantación de Lentes Intraoculares/métodos , Biometría/métodos , Anciano de 80 o más Años
6.
BMC Ophthalmol ; 24(1): 66, 2024 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-38355462

RESUMEN

BACKGROUND: Iridoschisis is a rare condition that primarily affects individuals aged 60-70 years. The predominant characteristics of iridoschisis involve the tissue splitting and separation of the iris stromal layers, often resulting in two distinct layers and the presence of floating fibers in the anterior chamber. This article reports the case of a 48-year-old male with iridoschisis with partial lens dislocation in both eyes. CASE PRESENTATION: Trauma is the leading factor in the development of iridoschisis. However, there is no documented case of ocular trauma in the patient's medical history. Visible white atrophic fibers were observed bilaterally in the anterior iris stroma of both eyes of the individual, accompanied by a small quantity of iris tissue within the anterior chamber. In this instance, the magnitude of the iridoschisis corresponded with the degree of lens dislocation. We were apprised that the patient had regularly used a cervical massager for a prolonged period of time, positioning it upon the ocular region. Frequent stimulation of both eyes with excessive force resulted in the development of iridoschisis and the partial dislocation of the lens.During the initial surgical procedure, phacoemulsification (Phaco) was carried out on the left eye without the placement of an intraocular lens (IOL). Following a two-month interval, we proceeded with the IOL suspension. Subsequently, the right eye underwent Phaco, accompanied by the implantation of an IOL. After closely monitoring the patient's progress for two months, it was evident that their vision had significantly improved, substantiating the success of the surgical interventions. CONCLUSIONS: This finding posits that the recurrent friction applied to both eyes may induce iridoschisis and various ocular complications. In the event of ocular intricacies manifesting, expeditious medical intervention becomes imperative.


Asunto(s)
Extracción de Catarata , Enfermedades del Iris , Subluxación del Cristalino , Lentes Intraoculares , Facoemulsificación , Masculino , Humanos , Persona de Mediana Edad , Enfermedades del Iris/diagnóstico , Enfermedades del Iris/cirugía , Iris/cirugía , Facoemulsificación/métodos , Subluxación del Cristalino/diagnóstico , Subluxación del Cristalino/etiología , Subluxación del Cristalino/cirugía
7.
Ophthalmic Surg Lasers Imaging Retina ; 55(5): 293-298, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38270569

RESUMEN

BACKGROUND AND OBJECTIVE: We describe an in-office lens repositioning technique for anterior crystalline lens dislocation. PATIENTS AND METHODS: We present a case series of four patients with spontaneous or traumatic anterior crystalline lens dislocation. RESULTS: The technique included supine patient positioning, gentle pressure with a cotton swab on the peripheral cornea to guide the lens into the posterior chamber, and the use of a miotic agent afterward to prevent subsequent subluxation. In the four cases described, the in-office technique successfully restored the lens to the posterior chamber, improved vision, and decreased intraocular pressure in most instances by resolving the angle closure secondary to pupillary block. CONCLUSIONS: The in-office lens repositioning technique is appropriate as an acute non-surgical intervention or temporizing measure for anterior crystalline lens dislocation. [Ophthalmic Surg Lasers Imaging Retina 2024;55:293-298.].


Asunto(s)
Subluxación del Cristalino , Cristalino , Humanos , Subluxación del Cristalino/cirugía , Subluxación del Cristalino/diagnóstico , Masculino , Cristalino/lesiones , Cristalino/cirugía , Femenino , Adulto , Persona de Mediana Edad , Agudeza Visual , Procedimientos Quirúrgicos Ambulatorios/métodos , Procedimientos Quirúrgicos Oftalmológicos/métodos
9.
Retin Cases Brief Rep ; 18(1): 15-17, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-35963000

RESUMEN

PURPOSE: The purpose of this study was to describe two cases of traumatic lens subluxation resulting from pickleball injury. METHODS: This is a case series. RESULTS: A 77-year-old man presented with worsening vision and was noted to have subluxation of his intraocular lens 10 days after being struck in the eye with a pickleball. The patient underwent a lens exchange with scleral fixation. A 76-year-old woman presented with blurry vision on the same day as her injury and was noted to have subluxation of her crystalline lens. She also underwent a lens insertion with scleral fixation. However, she experienced additional complications of postoperative cystoid macular edema and traumatic glaucoma. CONCLUSION: We recommend increased use of eye protection in pickleball.


Asunto(s)
Lesiones Oculares , Subluxación del Cristalino , Cristalino , Lentes Intraoculares , Masculino , Femenino , Humanos , Anciano , Implantación de Lentes Intraoculares/efectos adversos , Subluxación del Cristalino/diagnóstico , Subluxación del Cristalino/etiología , Subluxación del Cristalino/cirugía , Lentes Intraoculares/efectos adversos , Lesiones Oculares/complicaciones , Lesiones Oculares/diagnóstico , Estudios Retrospectivos , Complicaciones Posoperatorias/cirugía
10.
Indian J Ophthalmol ; 72(1): 126-127, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38131583

RESUMEN

Bimanual phacoemulsification has been established as a safe and efficacious means of nuclear emulsification in the past. This case report presents the use of this technique in a man in his early forties, who had subluxated cataractous lenses in both eyes. The technique allowed for effective nuclear emulsification within a closed chamber, providing better control over intraocular events. The report emphasizes the safety and effectiveness of bimanual phacoemulsification in cataract extraction, even in challenging cases like a subluxated lens.


Asunto(s)
Extracción de Catarata , Subluxación del Cristalino , Lentes Intraoculares , Facoemulsificación , Humanos , Masculino , Implantación de Lentes Intraoculares/métodos , Subluxación del Cristalino/diagnóstico , Subluxación del Cristalino/etiología , Subluxación del Cristalino/cirugía , Facoemulsificación/métodos , Adulto
12.
J AAPOS ; 27(4): 226-228, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37302726

RESUMEN

We present the case of a 14-year-old boy with a known diagnosis of Knobloch syndrome (KS) referred for bilateral cataract evaluation and possible cataract surgery. At time of initial presentation, no lens subluxation was appreciated, and no phacodonesis was detected on slit lamp biomicroscopy. However, 7-weeks later, on the day of surgery, his right eye was found to have a complete lens dislocation into the vitreous cavity, with no zonule attachment. The left eye did not have subluxated lens; however, intraoperatively, after irrigation into the eye, near complete zonular dialysis was observed. This case highlights the importance of regular follow-up of children with KS.


Asunto(s)
Extracción de Catarata , Catarata , Subluxación del Cristalino , Cristalino , Masculino , Humanos , Niño , Adolescente , Subluxación del Cristalino/diagnóstico , Subluxación del Cristalino/etiología , Subluxación del Cristalino/cirugía , Cristalino/cirugía , Catarata/complicaciones , Catarata/diagnóstico
16.
Int Ophthalmol ; 43(4): 1317-1324, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36149618

RESUMEN

PURPOSE: The aim of this study was to evaluate ocular and systemic risk factors for posterior chamber intraocular lens dislocation, as well as forms of manifestation. METHODS: A retrospective case-control study were all patients presented in the period 2012-2016 having intraocular lens dislocation and being treated with implantation of an iris-fixated intraocular lens was conducted at the University Hospital Mainz. As controls, pseudophakic patients presenting for other reasons were included. RESULTS: 150 eyes of 150 patients (mean age 72.7 ± 12.4 years, range 24-93 years) with IOL dislocation and 150 eyes of 103 controls were included in this study. The average time between primary implantation and IOL luxation was 86 months (iQR: 39.25-127 months) for all dislocations. Previous pars plana vitrectomy (PPV) (crudeOR = 2.14 (95% CI 1.23, 3.72), p = 0.011) and PEX (crudeOR = 11.6 (4.79, 28.12), p < 0.001) was linked with a higher risk of IOL luxation. Luxation occurs also earlier in patients with previous PPV and PEX than in eyes with neither PEX nor previous PPV (82.2 vs. 127 months). Rhegmatogenous retinal detachment was the major pathology that required a previous PPV for eyes with an IOL dislocation (57%). The average time between PPV and IOL dislocation was 74.67 months (range 0-186 months). CONCLUSION: Patients with a coexistence of both: PEX and a previous PPV had an elevated risk of IOL dislocation, and also had a shorter time interval between primary IOL implantation and IOL dislocation followed by eyes with PEX only and eyes with only a previous PPV.


Asunto(s)
Subluxación del Cristalino , Lentes Intraoculares , Humanos , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Implantación de Lentes Intraoculares/efectos adversos , Estudios Retrospectivos , Estudios de Casos y Controles , Agudeza Visual , Lentes Intraoculares/efectos adversos , Vitrectomía/efectos adversos , Subluxación del Cristalino/diagnóstico , Subluxación del Cristalino/etiología , Subluxación del Cristalino/cirugía , Factores de Riesgo , Complicaciones Posoperatorias/etiología
17.
Rev. bras. oftalmol ; 82: e0050, 2023. graf
Artículo en Portugués | LILACS | ID: biblio-1521785

RESUMEN

RESUMO Ao longo da vida, o cristalino produz novas fibras dispostas de forma concêntrica, que aumentam seu diâmetro anteroposterior e peso, tornando seu núcleo mais compacto e endurecido. A catarata hipermadura é uma forma de progressão avançada dessa proliferação de fibras, que pode desencadear uma variedade de complicações. A ruptura espontânea da cápsula anterior do cristalino, evoluindo com deslocamento anterior do núcleo, é uma complicação rara e com poucos casos publicados na literatura. Descrevemos o caso de uma paciente do sexo feminino, 68 anos, que apresentou ruptura espontânea da cápsula anterior do cristalino com deslocamento anterior do núcleo em olho esquerdo sem histórico de trauma ocular. A paciente foi submetida à facoemulsificação do cristalino e ao controle da pressão intraocular, evoluindo com melhora do quadro clínico.


ABSTRACT Throughout life, the lens produces new fibers arranged concentrically, which increase its anteroposterior diameter and weight, making its nucleus more compact and hardened. Hypermature cataract is an advanced stage of this fiber proliferation, which can trigger a variety of complications. Spontaneous rupture of the anterior lens capsule evolving with anterior displacement of the nucleus is a rare complication, with few cases published in the literature. We describe the case of a 68-year-old female patient, who presented spontaneous rupture of the anterior lens capsule with anterior displacement of the nucleus in the left eye, without a history of ocular trauma. The patient underwent phacoemulsification and clinical control of intraocular pressure, improving her condition.


Asunto(s)
Humanos , Femenino , Anciano , Catarata/complicaciones , Subluxación del Cristalino/diagnóstico , Subluxación del Cristalino/etiología , Cápsula Anterior del Cristalino/patología , Rotura Espontánea/cirugía , Catarata/terapia , Glaucoma Neovascular , Subluxación del Cristalino/cirugía , Ultrasonografía , Facoemulsificación/métodos , Microscopía con Lámpara de Hendidura , Presión Intraocular , Núcleo del Cristalino/patología , Cámara Anterior/patología
19.
Medicine (Baltimore) ; 101(35): e30428, 2022 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-36107580

RESUMEN

INTRODUCTION: Hypermature cataract is a form of late-stage cataract progression that can lead to a variety of complications. Spontaneous capsular rupture with lens nucleus displacement in hypermature cataracts has rarely been reported. We describe 2 cases of spontaneous dislocation of the lens nucleus in a hypermature cataract and perform a review of the literature on this complication. PATIENT CONCERNS: We report 2 rural men aged 50 and 76 years with deteriorating vision. DIAGNOSIS: The final diagnosis was senile hypermature cataract with dislocation of the lens nucleus in both patients and secondary glaucoma for the second patient. INTERVENTIONS AND OUTCOMES: During admission, both patients complained of deteriorating vision. Slit-lamp examination showed lens nucleus dislocation into the anterior chamber. The 50-year-old patient exhibited a residual lens capsule and a turbid cortex, with a normal anterior chamber and intraocular pressure. The 76-year-old patient presented a shrunken and ruptured capsule and no cortex in the pupillary area, mild inflammation in the anterior chamber, and high intraocular pressure. Both patients underwent intracapsular cataract extraction combined with anterior vitrectomy and achieved good postoperative recovery. CONCLUSION: Lens nucleus dislocation in hypermature cataracts can be seen in clinical practice, particularly in underdeveloped areas. Early recognition and surgery can improve vision.


Asunto(s)
Extracción de Catarata , Catarata , Glaucoma , Luxaciones Articulares , Cápsula del Cristalino , Subluxación del Cristalino , Anciano , Cámara Anterior , Catarata/complicaciones , Catarata/etiología , Extracción de Catarata/efectos adversos , Glaucoma/cirugía , Humanos , Luxaciones Articulares/cirugía , Subluxación del Cristalino/diagnóstico , Subluxación del Cristalino/etiología , Subluxación del Cristalino/cirugía , Masculino , Persona de Mediana Edad , Rotura Espontánea/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...