Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.417
Filtrar
1.
Vestn Oftalmol ; 140(2): 72-77, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38742501

RESUMEN

The modern treatment strategy for keratoconus (KC) involves sequential application of medical technologies aimed at stabilizing pathological changes in the cornea and restoring visual acuity. PURPOSE: This study compares the effect of implantation of intrastromal corneal ring segment (ICRS) and fitting of individual scleral rigid contact lenses (RCLs) on visual functions in patients with stage II-III KC after previously performed corneal collagen cross-linking. MATERIAL AND METHODS: The Helmholtz National Medical Research Center of Eye Diseases examined and treated 34 patients (69 eyes) aged 18 to 33 years with stage II-III KC. The study included patients who had previously undergone standard corneal collagen cross-linking. Depending on the type of optical correction, the patients were divided into two groups: patients in group 1 underwent ICRS implantation using a femtosecond laser; patients in group 2 were fitted with individual scleral RCLs. RESULTS: Improvement in clinical and functional parameters was observed in both groups. A higher clinical and functional result was achieved in group 2. CONCLUSION: For patients with stable stage II-III KC, it is advisable to recommend fitting of individual scleral RCLs for visual rehabilitation.


Asunto(s)
Lentes de Contacto , Queratocono , Esclerótica , Agudeza Visual , Humanos , Queratocono/cirugía , Queratocono/diagnóstico , Queratocono/fisiopatología , Queratocono/terapia , Femenino , Masculino , Adulto , Esclerótica/cirugía , Implantación de Prótesis/métodos , Implantación de Prótesis/instrumentación , Resultado del Tratamiento , Topografía de la Córnea , Prótesis e Implantes , Adulto Joven , Ajuste de Prótesis/métodos , Adolescente , Sustancia Propia/cirugía
2.
J Refract Surg ; 40(5): e328-e335, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717080

RESUMEN

PURPOSE: To evaluate moderate to high astigmatism corrections on the outcomes of SmartSight lenticule extraction for myopic astigmatism with a new femtosecond laser system. METHODS: Two hundred ninety-two eyes consecutively treated for myopic astigmatism with astigmatism magnitude greater than 1.00 diopter (D) were evaluated at the 6-month follow-up visit. The mean age of the patients was 29 ± 6 years with a mean spherical equivalent of -5.06 ± 2.20 diopters (D) and a mean magnitude of refractive astigmatism of 1.74 ± 0.61 D. RESULTS: At 6 months, astigmatism was 0.10 ± 0.20 D. Uncorrected and corrected distance visual acuities (UDVA and CDVA, respectively) were both 0.0 ± 0.1 logMAR. Differences between postoperative UDVA and preoperative CDVA and the change in CDVA were both +0.4 ± 0.7 lines better than preoperatively (P < .0003). CONCLUSIONS: Lenticule extraction treatment using Smart-Sight is safe and efficacious at 6 months. Findings suggest that moderate to high astigmatism improves after SmartSight lenticule extraction in the treatment of myopic astigmatism. [J Refract Surg. 2024;40(5):e328-e335.].


Asunto(s)
Astigmatismo , Sustancia Propia , Láseres de Excímeros , Miopía , Refracción Ocular , Agudeza Visual , Humanos , Astigmatismo/fisiopatología , Astigmatismo/cirugía , Agudeza Visual/fisiología , Estudios Retrospectivos , Adulto , Refracción Ocular/fisiología , Masculino , Femenino , Miopía/cirugía , Miopía/fisiopatología , Adulto Joven , Sustancia Propia/cirugía , Láseres de Excímeros/uso terapéutico , Topografía de la Córnea , Estudios de Seguimiento , Resultado del Tratamiento , Cirugía Laser de Córnea/métodos
3.
J Refract Surg ; 40(5): e291-e303, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717083

RESUMEN

PURPOSE: To compare differences in corneal densitometry (CD) and higher order aberrations (HOAs) in eyes that underwent small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for the treatment of myopia and myopic astigmatism at postoperative months 3, 6, and 12, and to evaluate their changes in a separate cohort of eyes after SMILE enhancement. METHODS: In this prospective, randomized, paired-eye clinical trial, consecutive eligible participants were randomized to undergo SMILE or FS-LASIK in either eye. Main outcome measures were CD and HOAs preoperatively and at 3, 6, and 12 months postoperatively. A separate cohort of consecutive patients who had SMILE and underwent enhancement were also included for comparison. RESULTS: For CD, no significant differences were found between SMILE and FS-LASIK up to month 12. For HOA measured by wavefront aberrometry, both SMILE and FS-LASIK had an increase in total root mean square (RMS) HOAs, spherical aberration (SA), and vertical coma up to month 12. SMILE had an additional increase in vertical quatrefoil, and FS-LASIK had an increase in horizontal coma at month 12. FS-LASIK had higher SA than SMILE, whereas SMILE had higher vertical quatrefoil than FS-LASIK at month 12. Central and posterior zone CD had significantly decreased after SMILE enhancement compared to after primary SMILE up to 2 years after enhancement. RMS HOAs, lower order aberrations, and SA were all increased after SMILE enhancement compared to after primary SMILE. CONCLUSIONS: SMILE induced lower SA but higher vertical quatrefoil than FS-LASIK at 1 year. Both SMILE and FS-LASIK had similar increases in RMS HOAs and vertical coma up to 1 year. There were no differences in CD between both groups. SMILE enhancement additionally had decreased central and posterior CD but greater RMS HOAs and SA compared to primary SMILE. [J Refract Surg. 2024;40(5):e291-e303.].


Asunto(s)
Aberrometría , Astigmatismo , Córnea , Sustancia Propia , Aberración de Frente de Onda Corneal , Densitometría , Queratomileusis por Láser In Situ , Láseres de Excímeros , Miopía , Refracción Ocular , Agudeza Visual , Humanos , Queratomileusis por Láser In Situ/métodos , Aberración de Frente de Onda Corneal/fisiopatología , Estudios Prospectivos , Miopía/cirugía , Miopía/fisiopatología , Adulto , Femenino , Masculino , Láseres de Excímeros/uso terapéutico , Agudeza Visual/fisiología , Sustancia Propia/cirugía , Córnea/cirugía , Córnea/fisiopatología , Adulto Joven , Refracción Ocular/fisiología , Astigmatismo/cirugía , Astigmatismo/fisiopatología , Cirugía Laser de Córnea/métodos , Topografía de la Córnea
4.
J Refract Surg ; 40(5): e321-e327, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717082

RESUMEN

PURPOSE: To evaluate the characteristic of corrective epithelial thickness after femtosecond laser-assisted lenticule intrastromal keratoplasty (LIKE) to correct moderate-to-high hyperopia. METHODS: The prospective case series study of the LIKE procedure was performed to correct moderate-to-high hyperopia. The epithelial thickness map was generated by anterior segment optical coherence tomography (AS-OCT) in the corneal central 9-mm zone. Keratometry and corneal higher order aberrations were analyzed by Pentacam (Oculus Optikgeräte GmbH) preoperatively and postoperatively. RESULTS: In the 26 eyes of 13 participants who underwent the LIKE procedure for moderate-to-high hyperopia, the attempted spherical equivalence (SEQ) was +6.50 ± 1.09 diopters (D). Compared to the preoperative epithelial thickness maps, the postoperative epithelial thickness had become significantly thinner in the central 5-mm zone; the difference was 6 to 7 µm. The paracentral epithelium performed nonuniform remodeling; the thinnest epithelial thickness was located in the inferotemporal section, which has the greatest difference from the superonasal; the difference between these two was approximately 3 µm. Through correlation analysis, it was found that the sections with thinner epithelium were significantly related to corneal curvature and corneal vertical coma. CONCLUSIONS: The LIKE procedure can be used to correct moderate-to-high hyperopia. This study further indicated the epithelial remodeling characteristic after the LIKE procedure: the central and paracentral corneal epithelial thickness becomes thinner, and the epithelial thickness distributes non-uniformly, which may be the important factor of the postoperative curvature asymmetric distribution and induction of corneal vertical coma. [J Refract Surg. 2024;40(5):e321-e327.].


Asunto(s)
Sustancia Propia , Topografía de la Córnea , Epitelio Corneal , Hiperopía , Refracción Ocular , Tomografía de Coherencia Óptica , Agudeza Visual , Humanos , Hiperopía/cirugía , Hiperopía/fisiopatología , Estudios Prospectivos , Sustancia Propia/cirugía , Sustancia Propia/patología , Masculino , Femenino , Adulto , Agudeza Visual/fisiología , Epitelio Corneal/cirugía , Epitelio Corneal/patología , Refracción Ocular/fisiología , Persona de Mediana Edad , Láseres de Excímeros/uso terapéutico , Adulto Joven , Aberración de Frente de Onda Corneal/fisiopatología , Cirugía Laser de Córnea/métodos , Enfermedades Hereditarias del Ojo
5.
BMC Ophthalmol ; 24(1): 211, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38741093

RESUMEN

OBJECTIVE: To investigate the correlation between higher-order aberrations (HOA) after small incision lenticule extraction (SMILE) and the severity of myopia and astigmatism, along with the relevant factors. These findings will provide valuable insights for decreasing the occurrence of HOA after SMILE and enhancing visual quality. METHODS: A total of 75 patients (150 eyes) with myopia and astigmatism who underwent SMILE were categorized into four groups based on the severity of myopia and astigmatism: Myopia Group 1 (Group M1, spherical diopter ranged from -1.00 D to -4.00 D), Myopia Group 2 (Group M2, spherical diopter ranged from -4.10 D to -10.00 D), Astigmatism Group 1 (Group A1, cylindrical diopter ranged from 0 D to -1.00 D), and Astigmatism Group 2 (Group A2, cylindrical diopter ranged from -1.10 D to -3.00 D). A comprehensive assessment was performed to examine the association between HOA and various relevant factors, including a detailed analysis of the subgroups. RESULTS: Group M1 had significantly lower levels of total eye coma aberration (CA), corneal total HOA (tHOA), internal tHOA, and vertical CA ( Z 3 - 1 ) after SMILE than Group M2 (P < 0.05). Similarly, Group A1 had significantly lower levels of total eye tHOA, CA, trefoil aberration (TA), corneal tHOA, TA, and vertical TA ( Z 3 - 3 ) after SMILE than Group A2 (P < 0.05). Pearson correlation analysis indicated a statistically significant positive relationship between the severity of myopia/astigmatism and most HOA (P < 0.05). Subgroup evaluations demonstrated a notable increase in postoperative HOA associated with myopia and astigmatism in Groups M2 and A2 compared with the control group. Lenticule thickness, postoperative central corneal thickness (CCT), postoperative uncorrected distance visual acuity (UDVA), and postoperative corneal Km and Cyl were strongly correlated with most HOA. Age, eyes, and postoperative intraocular pressure (IOP) were only associated with specific HOA. CONCLUSION: HOA positively correlated with the severity of myopia and astigmatism after SMILE. However, this relationship was not linear. HOA after SMILE was influenced by various factors, and additional specialized investigations are required to establish its clinical importance.


Asunto(s)
Astigmatismo , Cirugía Laser de Córnea , Aberración de Frente de Onda Corneal , Miopía , Refracción Ocular , Agudeza Visual , Humanos , Miopía/cirugía , Miopía/fisiopatología , Astigmatismo/fisiopatología , Astigmatismo/etiología , Masculino , Femenino , Adulto , Agudeza Visual/fisiología , Cirugía Laser de Córnea/métodos , Cirugía Laser de Córnea/efectos adversos , Aberración de Frente de Onda Corneal/fisiopatología , Aberración de Frente de Onda Corneal/etiología , Adulto Joven , Refracción Ocular/fisiología , Sustancia Propia/cirugía , Estudios Retrospectivos , Láseres de Excímeros/uso terapéutico , Complicaciones Posoperatorias , Topografía de la Córnea , Adolescente
6.
Sci Rep ; 14(1): 8732, 2024 04 16.
Artículo en Inglés | MEDLINE | ID: mdl-38627567

RESUMEN

We sought to evaluate the topographic risk factors for early myopic regression after small-incision lenticule extraction (SMILE). A retrospective case‒control study was conducted, and individuals who underwent SMILE surgery were enrolled. Among them, 406 and 14 eyes were categorized into the nonregression and regression groups, respectively. The preoperative and postoperative parameters in the two groups were collected, including spherical refraction (SE), axial length (AXL) and topographic data. A generalized linear model was adopted to analyze the difference in each parameter between the two groups. After 6 months, UCVA decreased in the regression group, and SE increased in the regression group (both P < 0.05). The increase in the CCT at the thinnest point (P = 0.044), flat corneal curvature (P = 0.012) and TCRP (P = 0.001) were significantly greater in the regression group. Regarding the risk factors for myopic regression, preoperative SE, preoperative sphere power, preoperative AXL, preoperative flat corneal curvature, preoperative SA, early postoperative SE, early postoperative sphere power, early postoperative AXL and early postoperative CCT difference were significantly greater in the regression group (all P < 0.05). The SE, sphere power, AXL, preoperative flat corneal curvature, preoperative SA, and postoperative CCT difference correlate with early myopic regression after SMILE.


Asunto(s)
Cirugía Laser de Córnea , Miopía , Herida Quirúrgica , Humanos , Córnea/cirugía , Sustancia Propia/cirugía , Agudeza Visual , Estudios Retrospectivos , Estudios de Casos y Controles , Cirugía Laser de Córnea/efectos adversos , Láseres de Excímeros/uso terapéutico , Refracción Ocular , Miopía/cirugía , Herida Quirúrgica/cirugía
7.
BMC Ophthalmol ; 24(1): 158, 2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38600456

RESUMEN

BACKGROUND: This study aimed to compare the visual outcomes of the first operated eyes with those of the second operated eyes following small-incision lenticule extraction (SMILE). METHODS: A total of 202 patients (404 eyes) underwent SMILE using the tear film mark centration method for myopia and myopic astigmatism correction. Baseline characteristics, objective optical quality, decentered displacement, induced corneal aberrations, and modulation transfer function (MTF) values were assessed. Linear regression analyzed the relationship between decentration and visual quality parameters, including corneal aberrations and MTF values. RESULTS: No significant difference was observed in objective visual quality, efficacy, and safety indexes between the two groups (all P > 0.05). The average decentered displacement for the first and second surgical eyes was 0.278 ± 0.17 mm and 0.315 ± 0.15 mm, respectively (P = 0.002). The horizontal coma in the first surgical eyes were notably lower than in the second (P = 0.000). MTF values at spatial frequencies of 5, 10, 15, and 20 cycles/degree (c/d) were higher in the first surgical eyes compared to the second (all P < 0.05). Linear regression indicated that high-order aberrations (HOAs), root mean square (RMS) coma, spherical aberration, horizontal coma, vertical coma, and eccentric displacement were all linearly correlated. Furthermore, MTF values exhibited a linear relationship with eccentric displacement across these spatial frequencies. CONCLUSIONS: There was no discernible difference in visual acuity, efficacy, or safety between the two operated eyes. Nonetheless, the first operated eyes exhibited reduced decentered displacement and demonstrated superior outcomes in terms of horizontal coma and MTF values compared to the second operated eyes following SMILE. The variations in visual quality parameters were linearly correlated with decentered displacement.


Asunto(s)
Astigmatismo , Aberración de Frente de Onda Corneal , Miopía , Humanos , Refracción Ocular , Coma , Topografía de la Córnea , Láseres de Excímeros/uso terapéutico , Miopía/cirugía , Astigmatismo/cirugía , Sustancia Propia/cirugía
8.
Indian J Ophthalmol ; 72(Suppl 3): S495-S500, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38648457

RESUMEN

PURPOSE: This retrospective longitudinal study evaluated the biomechanical E-staging in KC corneas before and after intracorneal ring segment (ICRS) implantation (Intacs® SK, Addition Technology, Illinois, United States). METHODS: Biomechanical E-staging for ectatic corneal diseases was applied retrospectively on 49 KC corneas of 41 patients who underwent ICRS implantation. The main outcome parameters included the Corvis Biomechanical Factor (CBiF, the linearized Corvis Biomechanical Index and the biomechanical parameters included), the resulting biomechanical E-staging, the stress-strain index, thinnest corneal thickness (TCT), maximal anterior keratometry (Kmax), and the anterior radius of curvature (ARC). They were evaluated at 1.9 ± 1.1 months preoperatively and postoperatively after 2.8 ± 0.7, 5.8 ± 1.0, and 10.6 ± 2.3 months. RESULTS: The CBiF decreased (4.9 ± 0.5 | 4.7 ± 0.5, P = 0.0013), and the E-staging increased significantly (2.8 ± 0.8 | 3.1 ± 0.9, P = 0.0012, paired t-test) from preoperatively to the first postoperative follow-up. The difference remained significant after 6 months; however, there was no more difference after 11 months. TCT was stable, whereas Kmax and ARC significantly decreased after ICRS implantation (TCT: 464 ± 49, 470 ± 51, 467 ± 38, 461 ± 48; Kmax: 56.3 ± 4.5, 54.7 ± 4.5, 54.2 ± 4.8, 54.1 ± 4.3; ARC: 51.5 ± 3.4, 48.3 ± 3.8, 48.6 ± 3.0, 48.6 ± 3.2 preoperatively and 3, 6, and 11 months postoperatively, respectively). Besides Kmax and ARC, Ambrósio's relational thickness to the horizontal profile (ARTh) was the only parameter that was significantly lower than preoperatively at any follow-up (P ≤ 0.0024, Wilcoxon matched-pairs test). CONCLUSION: Intacs® SK implantation results in an increasing biomechanical E-staging in the first postoperative months with stabilization near preoperative values after 1 year. Significantly lower ARTh values at any follow-up document the ICRS effect and contribute to a slightly higher postoperative biomechanical E-staging value.


Asunto(s)
Córnea , Sustancia Propia , Topografía de la Córnea , Queratocono , Prótesis e Implantes , Implantación de Prótesis , Agudeza Visual , Humanos , Queratocono/cirugía , Queratocono/diagnóstico , Queratocono/fisiopatología , Estudios Retrospectivos , Femenino , Masculino , Adulto , Implantación de Prótesis/métodos , Córnea/patología , Estudios de Seguimiento , Sustancia Propia/patología , Sustancia Propia/cirugía , Agudeza Visual/fisiología , Fenómenos Biomecánicos , Adulto Joven , Persona de Mediana Edad , Refracción Ocular/fisiología , Diseño de Prótesis , Adolescente
9.
BMC Ophthalmol ; 24(1): 117, 2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38481187

RESUMEN

BACKGROUND: To report a case of interface fluid syndrome (IFS) following traumatic corneal perforation repair after small incision lenticule extraction (SMILE). CASE PRESENTATION: A 23-year-old woman, with a past history of SMILE, was struck in the left eye with a barbecue prod and subsequently underwent corneal perforation repair at local hospital. Primary wound repaired with a single 10 - 0 nylon suture at the area of leakage. After the surgery, her best corrected visual acuity (BCVA) was 20/30. Four days later, she presented at our hospital with blurred vision, and interface fluid syndrome (IFS) was diagnosed. Intraoperative optical coherence tomography (iOCT) was used to guide the resuturing of the corneal perforation in the left eye, followed by anterior chamber gas injection. At the first postoperative month, the BCVA was 20/25. The corneal cap adhered closely to the stroma, the surface became smooth. CONCLUSIONS: This case illustrates that any corneal perforation following lamellar surgery, including SMILE, may lead to IFS. It is crucial to consider the depth of corneal perforation, and intraoperative optical coherence tomography (iOCT) plays a unique role in the repair procedure.


Asunto(s)
Perforación Corneal , Cirugía Laser de Córnea , Miopía , Humanos , Femenino , Adulto Joven , Adulto , Perforación Corneal/diagnóstico , Perforación Corneal/etiología , Perforación Corneal/cirugía , Miopía/cirugía , Miopía/diagnóstico , Sustancia Propia/cirugía , Procedimientos Quirúrgicos Oftalmológicos , Córnea , Tomografía de Coherencia Óptica/métodos , Cirugía Laser de Córnea/efectos adversos , Cirugía Laser de Córnea/métodos , Topografía de la Córnea , Láseres de Excímeros
10.
Int Ophthalmol ; 44(1): 153, 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38509410

RESUMEN

PURPOSE: This study aimed to measure the Raman spectrum of the human corneal stroma lens obtained from small incision lenticule extraction surgery (SMILE) in Asian myopic eyes using a confocal Raman micro-spectrometer built in the laboratory. METHODS: Forty-three myopic patients who underwent SMILE with equivalent diopters between - 4.00 and - 6.00 D were selected, and the right eye data were collected. Corneal stroma lenses were obtained during surgery, and the Raman spectra were measured after air drying. The complete Raman spectrum of human myopic corneal stroma lens tissue was obtained within the range of 700-4000 cm-1. RESULTS: Thirteen characteristic peaks were found, with the stronger peaks appearing at 937 cm-1, corresponding to proline, valine, and the protein skeleton of the human myopic corneal stroma lens; 1243 cm-1, corresponding to collagen protein; 1448 cm-1, corresponding to the collagen protein and phospholipids; and 2940 cm-1, corresponding to the amino acid and lipids, which was the strongest Raman peak. CONCLUSION: These results demonstrated that Raman spectroscopy has much potential as a fast, cost-effective, and reliable diagnostic tool in the diagnosis and treatment of eye diseases, including myopia, keratoconus, and corneal infection.


Asunto(s)
Cirugía Laser de Córnea , Queratomileusis por Láser In Situ , Miopía , Humanos , Sustancia Propia/cirugía , Agudeza Visual , Miopía/diagnóstico , Miopía/cirugía , Queratomileusis por Láser In Situ/métodos , Colágeno , Láseres de Excímeros , Refracción Ocular
11.
J Refract Surg ; 40(3): e133-e141, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38466766

RESUMEN

PURPOSE: To evaluate changes in posterior corneal asphericity (ΔQ) using the tangential radius of curvature after femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and small incision lenticule extraction (SMILE) procedures. METHODS: One hundred twenty right eyes of myopic patients who underwent either FS-LASIK or SMILE procedures were analyzed using Sirius 3D corneal topography for assessment. The tangential radius was employed to calculate both preoperative and postoperative posterior corneal Q-values across each semimeridian. After both surgical interventions, the ΔQ value variations across the 360° semimeridional regions of the posterior corneal surface were compared. RESULTS: A marked postoperative increase in the posterior corneal Q-value was documented. No significant differences were noted between the postoperative Q-values or ΔQ-values of the two surgical approaches. Among patients with moderate myopia, postoperative Q-value exhibited considerably lower increases and ΔQ-value significantly smaller than their counterparts with high myopia. Moreover, the fluctuation in ΔQ across semimeridional regions was less evident in patients with moderate myopia than in those with high myopia. Notably, the degree of ΔQ fluctuation across semimeridional regions was similar between both surgical categories. These data offer insights into variations in the posterior corneal surface after refractive surgeries depending on the degree of myopia, illuminating their clinical relevance. CONCLUSIONS: Both FS-LASIK and SMILE introduce notable changes to posterior corneal asphericity among patients with different myopia intensities. Furthermore, the influence on the asphericity across the entire posterior surface is similarly distributed between FS-LASIK and SMILE techniques. [J Refract Surg. 2024;40(3):e133-e141.].


Asunto(s)
Queratomileusis por Láser In Situ , Miopía , Herida Quirúrgica , Humanos , Queratomileusis por Láser In Situ/métodos , Sustancia Propia/cirugía , Radio (Anatomía) , Agudeza Visual , Láseres de Excímeros/uso terapéutico , Miopía/cirugía
12.
Zhonghua Yan Ke Za Zhi ; 60(3): 275-277, 2024 Mar 11.
Artículo en Chino | MEDLINE | ID: mdl-38462377

RESUMEN

A 31-year-old female patient with refractive error in both eyes underwent small incision lenticule extraction. On the 4th day after surgery, arc-shaped peripheral corneal infiltrates appeared in the right eye. Tobramycin and dexamethasone eye drops, 0.3% gatifloxacin eye drops, and a corneal bandage lens were applied to the eye. After bacterial infection was ruled out, dexamethasone sodium phosphate was injected subconjunctivally near the corneal lesion. The symptoms improved and the corneal lesion subsided afterwards.


Asunto(s)
Enfermedades de la Córnea , Cirugía Laser de Córnea , Miopía , Femenino , Humanos , Adulto , Sustancia Propia/cirugía , Agudeza Visual , Miopía/cirugía , Córnea/cirugía , Cirugía Laser de Córnea/efectos adversos , Enfermedades de la Córnea/cirugía , Soluciones Oftálmicas , Topografía de la Córnea , Refracción Ocular , Láseres de Excímeros
13.
Cornea ; 43(6): 784-789, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38437155

RESUMEN

PURPOSE: The purpose of this study was to highlight characteristic clinical and microscopic findings and report the long-term follow-up of pediatric excimer laser-assisted penetrating keratoplasty (excimer-PKP) for congenital stromal corneal dystrophy (CSCD). METHODS: A 2-year-old Greek child presented with CSCD at our department. Clinical examination showed bilateral flake-like whitish corneal opacities affecting the entire corneal stroma up to the limbus. Genetic testing identified a mutation of the decorin gene (c.962delA). The variant was not present in the parents and represented a de novo mutation. The uncorrected visual acuity was 20/100 in both eyes. Excimer-PKP (8.0/8.1 mm) was performed on the right eye at the age of 2.5 years and on the left eye at the age of 3 years. Postoperatively, alternating occlusion treatment was performed. RESULTS: The light microscopic examination demonstrated a disorganized extracellular matrix of the corneal stroma characterized by a prominent irregular arrangement of stromal collagen lamellae with large interlamellar clefts containing ground substance, highlighted by periodic acid-Schiff- and Alcian blue-positive reaction detecting acid mucopolysaccharides. Electron microscopy showed disorganization and caliber variation of collagen lamellae and thin filaments within an electron-lucent ground substance. The postoperative course was unremarkable. Both grafts remained completely clear 14 years postoperatively. Corneal tomography showed moderate regular astigmatism with normal corneal thickness. The corrected distance visual acuity was 20/25 in both eyes. CONCLUSIONS: Excimer-PKP for CSCD might be associated with excellent long-term results and a good prognosis, particularly when the primary surgery is performed at a very young age. However, this requires close postoperative follow-up examinations by an experienced pediatric ophthalmologist to avoid severe amblyopia.


Asunto(s)
Distrofias Hereditarias de la Córnea , Queratoplastia Penetrante , Láseres de Excímeros , Agudeza Visual , Humanos , Queratoplastia Penetrante/métodos , Estudios de Seguimiento , Distrofias Hereditarias de la Córnea/cirugía , Distrofias Hereditarias de la Córnea/fisiopatología , Preescolar , Agudeza Visual/fisiología , Láseres de Excímeros/uso terapéutico , Masculino , Sustancia Propia/cirugía , Sustancia Propia/patología , Femenino , Decorina/genética
14.
PLoS One ; 19(2): e0288181, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38319899

RESUMEN

OBJECTIVES: To identify predictive factors and to construct predictive models using epidemiological and clinical preoperative factors for the visual acuity change after intracorneal ring segment (ICRS) implantation in patients with keratoconus. METHODS: The medical records of 287 keratoconic eyes of 230 patients implanted with ICRS at Chula Refractive Surgery Center of a tertiary university hospital (Bangkok, Thailand) between January 2012 and March 2022 were retrospectively reviewed for epidemiological and clinical preoperative variables, including those derived from Scheimpflug tomography. After randomly excluding one eye for each bilateral case, the remaining 230 eyes were randomized into two groups: a training group (184 eyes) and a validation group (46 eyes). In the training group, the correlation between the interesting variables and postoperative uncorrected and corrected distance visual acuity change (ΔUDVA and ΔCDVA; logMAR scale) at 6 months was explored, and then the multiple linear regression analysis was used to develop the predictive models. The obtained models were tested using the validation group. RESULTS: There were 5 and 14 preoperative variables that statistically correlated with ΔUDVA and ΔCDVA respectively. Only the preoperative corrected distance visual acuity (CDVAp) strongly correlated with ΔCDVA (Beta = -0.746). Using multiple regression, the preoperative uncorrected distance visual acuity (UDVAp) and front mean keratometry were selected in the proposed model for ΔUDVA (adjusted R2 = 38.8%), while the CDVAp and index of surface variance (ISV) were selected in the model [Formula: see text] (adjusted R2 = 48.9%). The ΔUDVA and ΔCDVA models were correct in 47.83% and 63.4% of the validation group within 0.20 logMAR, respectively. CONCLUSIONS: Potential predictive factors and models for ICRS-induced changes in visual acuity are proposed as adjunctive tools for clinicians. Such tools could be used for case selection and during counselling before ICRS implantation to maximize surgical outcomes.


Asunto(s)
Queratocono , Humanos , Sustancia Propia/cirugía , Topografía de la Córnea , Ojo Artificial , Queratocono/cirugía , Prótesis e Implantes , Implantación de Prótesis/métodos , Refracción Ocular , Estudios Retrospectivos , Tailandia
15.
Indian J Ophthalmol ; 72(5): 745-747, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38389247

RESUMEN

Lamellar surgeries have revolutionized our understanding and practice of keratoplasties. However, the learning curve in deep anterior lamellar keratoplasty (DALK) makes it daunting for novice surgeons. This paper describes a unique intraoperative sign - the radial "spike sign," which heralds the commencement of a big bubble in some cases of advanced keratoconus in eyes that have not undergone any previous surgery. The spike sign was noted during big bubble DALK surgery and was then retrospectively looked for in recorded DALK surgical videos and correlated with the formation of a big bubble. The movement of air after injection was classified into the direct formation of a big bubble, stromal emphysema with no big bubble, and emphysema with the spike sign followed by a big bubble. In total, 104 surgical videos of big bubble attempts were evaluated and classified as such. The spike sign helps reduce the number of unnecessary attempts at big bubble formation during DALK, thus improving surgical outcomes.


Asunto(s)
Trasplante de Córnea , Queratocono , Humanos , Queratocono/cirugía , Queratocono/diagnóstico , Trasplante de Córnea/métodos , Estudios Retrospectivos , Masculino , Complicaciones Intraoperatorias , Agudeza Visual , Adulto , Femenino , Sustancia Propia/cirugía , Sustancia Propia/patología
16.
Cornea ; 43(3): 398-401, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38315501

RESUMEN

ABSTRACT: Corneal allogeneic intrastromal ring segments (CAIRS) refer to the placement of allogeneic rings and segments in intrastromal channels within the cornea. Currently, a deepithelialized donor cornea is used as the allogeneic source for CAIRS and the cut ring is turned sideways and implanted so that the thickness can be varied by varying the distance between the concentric trephine blades. In addition, to obtain a greater effect, CAIRSs are preferred to be implanted with the Bowman layer (BL) facing the corneal apex and posterior stroma facing limbally. Being flexible tissue, it is, however, important to prevent twisting and to maintain correct orientation. We describe a simple technique of marking the BL with a gentian violet surgical marker to simplify CAIRS insertion. BL marking allows easy visibility of twists and helps identify improper orientation, thus allowing correct insertion of CAIRS.


Asunto(s)
Trasplante de Células Madre Hematopoyéticas , Queratocono , Humanos , Sustancia Propia/cirugía , Córnea/cirugía , Prótesis e Implantes , Implantación de Prótesis , Topografía de la Córnea , Queratocono/cirugía
17.
J Fr Ophtalmol ; 47(4): 104085, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38377878

RESUMEN

PURPOSE: To evaluate the safety, efficacy and postoperative visual quality of small incision lenticule extraction (SMILE) and Wavefront-Guided Laser in situ keratomileusis (WFG-LASIK) and to analyze their efficacy in correcting astigmatism. METHODS: A systematic literature search was performed using Cochrane Collaboration methodology. Databases searched included PubMed, Embase, the Cochrane Library and Web of Science. RevMan software version 5.3.0 was used for meta-analysis. RESULTS: A total of 976 eyes were included in 8 studies, of which 539 eyes underwent SMILE and 437 eyes underwent WFG-LASIK. There were no statistically significant differences in the proportion of eyes achieving uncorrected distance visual acuity of 20/20 or better (P=0.18), the proportion of eyes within±0.50 diopter of target refraction postoperatively (P=0.10), or the postoperative magnitude of cylinder (P=0.10). Regarding the Alpins vector analysis of astigmatism, there was no statistically significant difference in the surgical magnitude of error (P=0.09) between the two groups. WFG-LASIK has a lower surgical angle of error (P= 0.002) and higher surgical correction index of cylinder (P=0.03) than SMILE. In terms of aberrations, higher order aberrations (P=0.46), spherical aberrations (P=0.22) and trefoil (P=0.56) were not statistically different, while WFG-LASIK induced less coma than SMILE surgery (P=0.02). CONCLUSION: Both SMILE and WFG-LASIK are safe and effective ways to correct myopia and astigmatism. Compared with SMILE, WFG-LASIK has a lower surgical angle of error, higher surgical correction index of cylinder and induces less coma.


Asunto(s)
Astigmatismo , Queratomileusis por Láser In Situ , Miopía , Herida Quirúrgica , Humanos , Queratomileusis por Láser In Situ/efectos adversos , Queratomileusis por Láser In Situ/métodos , Astigmatismo/cirugía , Coma/cirugía , Láseres de Excímeros/uso terapéutico , Estudios Prospectivos , Refracción Ocular , Córnea , Sustancia Propia/cirugía , Miopía/cirugía , Resultado del Tratamiento
18.
Int Ophthalmol ; 44(1): 52, 2024 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-38340212

RESUMEN

PURPOSE: To evaluate the initial visual outcomes of Small Incision Lenticule Extraction (SMILE) Pro® using a 2 MHz femtosecond laser (VisuMax 800, Carl Zeiss Meditec) and to assess the efficacy, safety, predictability, accuracy, and complication rate. METHODS: This retrospective analysis included eyes which underwent the SMILE Pro® procedure using VisuMax 800 femtosecond laser to correct myopia. All surgeries were performed by one surgeon (DB). Follow-up was conducted 3 months postoperatively to evaluate visual outcomes after neuroadaptation, corrected visual acuity (CDVA) and intra- and postoperative complications. RESULTS: One hundred and fifty-two eyes of 82 patients (mean age 31 ± 6 years) results at 3 months are presented. The mean spherical equivalent (SE) was - 4.44 ± 1.86 D preoperatively while -0.24 ± 0.32 D postoperatively. 99% of eyes achieved SE within ± 1.0 D of attempted correction and 91% were within ± 0.5 D. Efficacy index was 0.93 while the safety index was 1. No complications occurred intra- or postoperatively. No eyes lost more than 1 line of their preoperative CDVA. All highly myopic eyes (- 6.25 to - 10.00 D; n = 18) achieved 20/20 at 3 months postoperatively and were within 0.5 D from the attempted SE and no eyes lost more than 1 line of CDVA. CONCLUSION: The SMILE Pro® is a safe, efficient, and predictable procedure for the treatment of myopia and myopic astigmatism, with comparable results of conventional SMILE surgery. High myopic eyes achieve better results than low and moderate myopia. No complications were recorded in our patients.


Asunto(s)
Astigmatismo , Cirugía Laser de Córnea , Miopía , Humanos , Adulto , Agudeza Visual , Estudios Retrospectivos , Refracción Ocular , Córnea/cirugía , Sustancia Propia/cirugía , Miopía/cirugía , Astigmatismo/cirugía , Rayos Láser , Resultado del Tratamiento , Láseres de Excímeros/uso terapéutico
19.
Int Ophthalmol ; 44(1): 50, 2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38336951

RESUMEN

PURPOSE: Intrastromal corneal ring segment (ICRS) implantation is a surgical technique developed with the purpose of avoiding the progression of corneal protrusion and is considered a viable option for managing patients with keratoconus as it stabilizes or improves vision thus delaying or excluding the need of more advanced surgical intervention such as penetrating keratoplasty. However, long term follow up is still limited to determine its actual success in achieving this goal. The current project aims to provide an extended follow up reporting a mean followup of around 5 years, extending up to 12.5 years. METHODS: We recruited patients who performed their ICRS between 2008 and 2013. We contacted patients for a follow up exam with a possible corneal tomography. For each patient, we obtained baseline pre operative data and latest follow up data which included visual acuity, subjective refraction, clinical slit-lamp exam, and corneal tomography. We compared the change in best corrected visual acuity and maximum keratometry readings from clinical visits before ring implantation to the latest follow up. RESULTS: A total of 68 eyes for 53 patients were included. The mean duration of follow up was 53.87 (± 38.8) months, with a maximum duration of 153 months. We found a significant improvement in corrected and uncorrected visual acuity, keratometries and refraction during the follow up period. On correlation analysis, strong negative significant correlation was found between duration since surgery and change in uncorrected visual acuity (p = 0.03, ρ = 0.338) and mean keratometry values (p = 0.033, ρ = 0.296). At the latest follow up for majority of patients with more than 100 weeks of follow up (12 eyes), uncorrected visual acuity were equal to or worse than baseline. CONCLUSION: This study represents the largest follow up for ICRS implanted in keratoconus patients. Improvement of visual acuity following ICRS implantation can be expected in the first few years, after which, a decline occurring thereafter.


Asunto(s)
Queratocono , Humanos , Queratocono/diagnóstico , Queratocono/cirugía , Estudios de Seguimiento , Sustancia Propia/cirugía , Topografía de la Córnea , Implantación de Prótesis , Refracción Ocular , Prótesis e Implantes , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...