Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
J Nucl Cardiol ; 24(1): 212-223, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-26396025

RESUMEN

BACKGROUND: Performing both single photon emission computerized tomography (SPECT) and coronary computed tomography angiography (CCTA) in patients suspected for coronary artery disease (CAD) leads to increased radiation exposure. We evaluated the need for additional imaging and following implications for radiation exposure of a sequential SPECT/computed tomography (CT) algorithm. METHODS AND RESULTS: 5018 consecutive patients without history of CAD were referred for stress-first SPECT and coronary artery calcium (CAC) scoring. If stress SPECT was abnormal, additional rest SPECT and, if feasible, CCTA were acquired. Stress SPECT was normal in 2617 patients (52%). CCTA was not performed in 1289 of the 2401 patients referred for additional imaging (54%), mainly because of severe CAC (47%) or fast/irregular heart rate (22%). 642 patients with abnormal SPECT underwent CCTA, which excluded significant CAD in 378 patients (59%). Mean radiation dose was 4.5 ± 0.3 mSv for stress-only imaging and 13.2 ± 3.3 mSv for additional imaging (P < 0.001). CONCLUSIONS: Half of the patients do not require additional imaging in our sequential SPECT/CT algorithm, which is accompanied with low radiation exposure. CCTA cannot be performed in half of the patients who undergo additional imaging because of (relative) contra-indications. CCTA is able to correct for false-positive SPECT findings in our algorithm.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/epidemiología , Uso Excesivo de los Servicios de Salud/estadística & datos numéricos , Exposición a la Radiación/prevención & control , Exposición a la Radiación/estadística & datos numéricos , Derivación y Consulta/estadística & datos numéricos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricos , Progresión de la Enfermedad , Femenino , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Evaluación de Necesidades , Países Bajos/epidemiología , Prevalencia , Factores de Riesgo , Técnica de Sustracción/estadística & datos numéricos , Revisión de Utilización de Recursos
2.
Magn Reson Med Sci ; 15(1): 146-8, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26104080

RESUMEN

We propose a novel image processing technique that combines images routinely acquired with low and high b values to create a single image that contains clinically useful information without the ambiguity of T2 shine-through. The contrast of resulting images is similar to that of a T2 image, but the signals of pixels with low apparent diffusion coefficient (ADC) values are inverted. The proposed technique takes the threshold ADC value as the one adjustable parameter.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/estadística & datos numéricos , Procesamiento de Imagen Asistido por Computador/estadística & datos numéricos , Algoritmos , Humanos , Técnica de Sustracción/estadística & datos numéricos
3.
Med Image Anal ; 24(1): 205-219, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26201875

RESUMEN

Multi-atlas segmentation (MAS), first introduced and popularized by the pioneering work of Rohlfing, et al. (2004), Klein, et al. (2005), and Heckemann, et al. (2006), is becoming one of the most widely-used and successful image segmentation techniques in biomedical applications. By manipulating and utilizing the entire dataset of "atlases" (training images that have been previously labeled, e.g., manually by an expert), rather than some model-based average representation, MAS has the flexibility to better capture anatomical variation, thus offering superior segmentation accuracy. This benefit, however, typically comes at a high computational cost. Recent advancements in computer hardware and image processing software have been instrumental in addressing this challenge and facilitated the wide adoption of MAS. Today, MAS has come a long way and the approach includes a wide array of sophisticated algorithms that employ ideas from machine learning, probabilistic modeling, optimization, and computer vision, among other fields. This paper presents a survey of published MAS algorithms and studies that have applied these methods to various biomedical problems. In writing this survey, we have three distinct aims. Our primary goal is to document how MAS was originally conceived, later evolved, and now relates to alternative methods. Second, this paper is intended to be a detailed reference of past research activity in MAS, which now spans over a decade (2003-2014) and entails novel methodological developments and application-specific solutions. Finally, our goal is to also present a perspective on the future of MAS, which, we believe, will be one of the dominant approaches in biomedical image segmentation.


Asunto(s)
Algoritmos , Interpretación de Imagen Asistida por Computador/métodos , Reconocimiento de Normas Patrones Automatizadas/estadística & datos numéricos , Técnica de Sustracción/estadística & datos numéricos , Humanos , Reconocimiento de Normas Patrones Automatizadas/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
4.
Br J Oral Maxillofac Surg ; 53(1): 54-7, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25445390

RESUMEN

To identify the incidence of different causes of benign obstruction of the salivary glands, we retrospectively analysed 788 anonymised sialography reports of 719 patients referred to the department of dental and maxillofacial radiology between 2006 and 2012. Reports that showed evidence of benign obstruction were included (n=493). Salivary stones were identified in 151 (31%), ductal strictures in 115 (23%), and mucus plugs in 295 (60%). In 67 cases (14%) there was evidence of 2 or 3 causes of obstruction. As previously reported, mucous plugs were the most common finding, possibly because of the use of fluoroscopy or digital subtraction sialography, or both. These methods enable images to be captured during the initial filling of the main duct and are likely to prevent mucus plugs from being obscured by the contrast medium, which is the case in conventional sialography when a single image is produced after the contrast has been injected.


Asunto(s)
Fluoroscopía/estadística & datos numéricos , Enfermedades de las Glándulas Salivales/epidemiología , Sialografía/estadística & datos numéricos , Técnica de Sustracción/estadística & datos numéricos , Adolescente , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Constricción Patológica/epidemiología , Medios de Contraste , Femenino , Humanos , Incidencia , Londres/epidemiología , Masculino , Persona de Mediana Edad , Moco/diagnóstico por imagen , Estudios Retrospectivos , Conductos Salivales/patología , Cálculos de las Glándulas Salivales/epidemiología , Adulto Joven
5.
AJR Am J Roentgenol ; 204(1): 83-91, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25539241

RESUMEN

OBJECTIVE: The purpose of this article is to compare transrectal ultrasound (TRUS) biopsy accuracies of operators with different levels of prostate MRI experience using cognitive registration versus MRI-TRUS fusion to assess the preferred method of TRUS prostate biopsy for MRI-identified lesions. SUBJECTS AND METHODS; One hundred patients from a prospective prostate MRI-TRUS fusion biopsy study were reviewed to identify all patients with clinically significant prostate adenocarcinoma (PCA) detected on MRI-targeted biopsy. Twenty-five PCA tumors were incorporated into a validated TRUS prostate biopsy simulator. Three prostate biopsy experts, each with different levels of experience in prostate MRI and MRI-TRUS fusion biopsy, performed a total of 225 simulated targeted biopsies on the MRI lesions as well as regional biopsy targets. Simulated biopsies performed using cognitive registration with 2D TRUS and 3D TRUS were compared with biopsies performed under MRI-TRUS fusion. RESULTS: Two-dimensional and 3D TRUS sampled only 48% and 45% of clinically significant PCA MRI lesions, respectively, compared with 100% with MRI-TRUS fusion. Lesion sampling accuracy did not statistically significantly vary according to operator experience or tumor volume. MRI-TRUS fusion-naïve operators showed consistent errors in targeting of the apex, midgland, and anterior targets, suggesting that there is biased error in cognitive registration. The MRI-TRUS fusion expert correctly targeted the prostate apex; however, his midgland and anterior mistargeting was similar to that of the less-experienced operators. CONCLUSION: MRI-targeted TRUS-guided prostate biopsy using cognitive registration appears to be inferior to MRI-TRUS fusion, with fewer than 50% of clinically significant PCA lesions successfully sampled. No statistically significant difference in biopsy accuracy was seen according to operator experience with prostate MRI or MRI-TRUS fusion.


Asunto(s)
Competencia Clínica/estadística & datos numéricos , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/estadística & datos numéricos , Imagen por Resonancia Magnética Intervencional/estadística & datos numéricos , Neoplasias de la Próstata/patología , Técnica de Sustracción/estadística & datos numéricos , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Análisis y Desempeño de Tareas
6.
J Ultrasound Med ; 32(9): 1557-64, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23980215

RESUMEN

OBJECTIVES: The purpose of this study was to evaluate the effectiveness of real-time fusion imaging (sonography combined with computed tomography or magnetic resonance imaging) for percutaneous sonographically guided biopsy of focal hepatic lesions with poor sonographic conspicuity. METHODS: This study was conducted as a retrospective analysis of a prospective database and was approved by the Institutional Review Board. Patients who had target lesions with poor conspicuity on B-mode sonography for percutaneous biopsy were enrolled in the study. Lesion conspicuity was assessed by conventional B-mode sonography first and then by fusion imaging later in the same session. We compared lesion conspicuity and detection rates between B-mode sonography and fusion imaging and evaluated how many cases of initially invisible lesions on B-mode sonography became visible on fusion imaging. The technical success rate was evaluated on the basis of the final diagnoses, which were established by pathologic examination of the biopsy specimens as well as follow-up clinical and radiologic examinations. RESULTS: A total of 22 patients were enrolled in the study. On fusion imaging, lesion conspicuity was increased in 63.6% of focal hepatic lesions (14 of 22). Moreover, 66.7% of lesions (6 of 9) that were invisible on B-mode sonography became visible on fusion imaging. The true-positive detection rate was significantly different between B-mode sonography and fusion imaging (9 of 22 versus 19 of 22; P = .0044). Percutaneous biopsy was performed for all lesions, including 3 target lesions that were invisible even on fusion imaging. The technical success rate was 95.5% (21 of 22). CONCLUSIONS: Fusion imaging is effective for percutaneous biopsy of focal hepatic lesions with poor sonographic conspicuity.


Asunto(s)
Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/métodos , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/estadística & datos numéricos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/epidemiología , Técnica de Sustracción/estadística & datos numéricos , Ultrasonografía/estadística & datos numéricos , Adulto , Anciano , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Reproducibilidad de los Resultados , República de Corea/epidemiología , Estudios Retrospectivos , Factores de Riesgo , Sensibilidad y Especificidad
7.
Radiology ; 268(3): 752-60, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23687175

RESUMEN

PURPOSE: To perform external validation of a computer-assisted registration algorithm for prone and supine computed tomographic (CT) colonography and to compare the results with those of an existing centerline method. MATERIALS AND METHODS: All contributing centers had institutional review board approval; participants provided informed consent. A validation sample of CT colonographic examinations of 51 patients with 68 polyps (6-55 mm) was selected from a publicly available, HIPAA compliant, anonymized archive. No patients were excluded because of poor preparation or inadequate distension. Corresponding prone and supine polyp coordinates were recorded, and endoluminal surfaces were registered automatically by using a computer algorithm. Two observers independently scored three-dimensional endoluminal polyp registration success. Results were compared with those obtained by using the normalized distance along the colonic centerline (NDACC) method. Pairwise Wilcoxon signed rank tests were used to compare gross registration error and McNemar tests were used to compare polyp conspicuity. RESULTS: Registration was possible in all 51 patients, and 136 paired polyp coordinates were generated (68 polyps) to test the algorithm. Overall mean three-dimensional polyp registration error (mean ± standard deviation, 19.9 mm ± 20.4) was significantly less than that for the NDACC method (mean, 27.4 mm ± 15.1; P = .001). Accuracy was unaffected by colonic segment (P = .76) or luminal collapse (P = .066). During endoluminal review by two observers (272 matching tasks, 68 polyps, prone to supine and supine to prone coordinates), 223 (82%) polyp matches were visible (120° field of view) compared with just 129 (47%) when the NDACC method was used (P < .001). By using multiplanar visualization, 48 (70%) polyps were visible after scrolling ± 15 mm in any multiplanar axis compared with 16 (24%) for NDACC (P < .001). CONCLUSION: Computer-assisted registration is more accurate than the NDACC method for mapping the endoluminal surface and matching the location of polyps in corresponding prone and supine CT colonographic acquisitions.


Asunto(s)
Algoritmos , Pólipos del Colon/diagnóstico por imagen , Pólipos del Colon/epidemiología , Colonografía Tomográfica Computarizada/estadística & datos numéricos , Posicionamiento del Paciente/estadística & datos numéricos , Intensificación de Imagen Radiográfica/métodos , Técnica de Sustracción/estadística & datos numéricos , Puntos Anatómicos de Referencia/diagnóstico por imagen , Humanos , Prevalencia , Posición Prona , Posición Supina , Estados Unidos/epidemiología
8.
Radiology ; 268(3): 761-9, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23564713

RESUMEN

PURPOSE: To evaluate the diagnostic performance of multiparametric (MP) magnetic resonance (MR) imaging for prostate cancer detection by using transperineal template prostate mapping (TTPM) biopsies as the reference standard and to determine the potential ability of MP MR imaging to identify clinically significant prostate cancer. MATERIALS AND METHODS: Institutional review board exemption was granted by the local research ethics committee for this retrospective study. Included were 64 men (mean age, 62 years [range, 40-76]; mean prostate-specific antigen, 8.2 ng/mL [8.2 µg/L] [range, 2.1-43 ng/mL]), 51 with biopsy-proved cancer and 13 suspected of having clinically significant cancer that was biopsy negative or without prior biopsy. MP MR imaging included T2-weighted, dynamic contrast-enhanced and diffusion-weighted imaging (1.5 T, pelvic phased-array coil). Three radiologists independently reviewed images and were blinded to results of biopsy. Two-by-two tables were derived by using sectors of analysis of four quadrants, two lobes, and one whole prostate. Primary target definition for clinically significant disease necessary to be present within a sector of analysis on TTPM for that sector to be deemed positive was set at Gleason score of 3+4 or more and/or cancer core length involvement of 4 mm or more. Sensitivity, negative predictive value, and negative likelihood ratio were calculated to determine ability of MP MR imaging to rule out cancer. Specificity, positive predictive value, positive likelihood ratio, accuracy (overall fraction correct), and area under receiver operating characteristic curves were also calculated. RESULTS: Twenty-eight percent (71 of 256) of sectors had clinically significant cancer by primary endpoint definition. For primary endpoint definition (≥ 4 mm and/or Gleason score ≥ 3+4), sensitivity, negative predictive value, and negative likelihood ratios were 58%-73%, 84%-89%, and 0.3-0.5, respectively. Specificity, positive predictive value, and positive likelihood ratios were 71%-84%, 49%-63%, and 2.-3.44, respectively. Area under the curve values were 0.73-0.84. CONCLUSION: Results of this study indicate that MP MR imaging has a high negative predictive value to rule out clinically significant prostate cancer and may potentially have clinical use in diagnostic pathways of men at risk.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/normas , Neoplasias de la Próstata/patología , Técnica de Sustracción/estadística & datos numéricos , Anciano , Estudios de Cohortes , Humanos , Masculino , Persona de Mediana Edad , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Reino Unido
9.
AJR Am J Roentgenol ; 200(5): 1006-13, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23617482

RESUMEN

OBJECTIVE: The objective of our study was to compare the effect of dual-energy subtraction and bone suppression software alone and in combination with computer-aided detection (CAD) on the performance of human observers in lung nodule detection. MATERIALS AND METHODS: One hundred one patients with from one to five lung nodules measuring 5-29 mm and 42 subjects with no nodules were retrospectively selected and randomized. Three independent radiologists marked suspicious-appearing lesions on the original chest radiographs, dual-energy subtraction images, and bone-suppressed images before and after postprocessing with CAD. Marks of the observers and CAD marks were compared with CT as the reference standard. Data were analyzed using nonparametric tests and the jackknife alternative free-response receiver operating characteristic (JAFROC) method. RESULTS: Using dual-energy subtraction alone (p = 0.0198) or CAD alone (p = 0.0095) improved the detection rate compared with using the original conventional chest radiograph. The combination of bone suppression and CAD provided the highest sensitivity (51.6%) and the original nonenhanced conventional chest radiograph alone provided the lowest (46.9%; p = 0.0049). Dual-energy subtraction and bone suppression provided the same false-positive (p = 0.2702) and true-positive (p = 0.8451) rates. Up to 22.9% of lesions were found only by the CAD program and were missed by the readers. JAFROC showed no difference in the performance between modalities (p = 0.2742-0.5442). CONCLUSION: Dual-energy subtraction and the electronic bone suppression program used in this study provided similar detection rates for pulmonary nodules. Additionally, CAD alone or combined with bone suppression can significantly improve the sensitivity of human observers for pulmonary nodule detection.


Asunto(s)
Competencia Profesional/estadística & datos numéricos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Imagen Radiográfica por Emisión de Doble Fotón/estadística & datos numéricos , Radiografía Torácica/estadística & datos numéricos , Nódulo Pulmonar Solitario/diagnóstico por imagen , Nódulo Pulmonar Solitario/epidemiología , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Huesos/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Intensificación de Imagen Radiográfica/métodos , Radiografía Torácica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Técnica de Sustracción/estadística & datos numéricos , Suiza/epidemiología , Tomografía Computarizada por Rayos X/métodos
10.
Radiology ; 266(1): 104-13, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23169790

RESUMEN

PURPOSE: To compare radiologists' diagnostic accuracy and recall rates for breast tomosynthesis combined with digital mammography versus digital mammography alone. MATERIALS AND METHODS: Institutional review board approval was obtained at each accruing institution. Participating women gave written informed consent. Mediolateral oblique and craniocaudal digital mammographic and tomosynthesis images of both breasts were obtained from 1192 subjects. Two enriched reader studies were performed to compare digital mammography with tomosynthesis against digital mammography alone. Study 1 comprised 312 cases (48 cancer cases) with images read by 12 radiologists; study 2, 312 cases (51 cancer cases) with 15 radiologists. Study 1 readers recorded only that an abnormality requiring recall was present; study 2 readers had additional training and recorded both lesion type and location. Diagnostic accuracy was compared with receiver operating characteristic analysis. Recall rates of noncancer cases, sensitivity, specificity, and positive and negative predictive values determined by analyzing Breast Imaging Reporting and Data System scores were compared for the two methods. RESULTS: Diagnostic accuracy for combined tomosynthesis and digital mammography was superior to that of digital mammography alone. Average difference in area under the curve in study 1 was 7.2% (95% confidence interval [CI]: 3.7%, 10.8%; P < .001) and in study 2 was 6.8% (95% CI: 4.1%, 9.5%; P < .001). All 27 radiologists increased diagnostic accuracy with addition of tomosynthesis. Recall rates for noncancer cases for all readers significantly decreased with addition of tomosynthesis (range, 6%-67%; P < .001 for 25 readers, P < .03 for all readers). Increased sensitivity was largest for invasive cancers: 15% and 22% in studies 1 and 2 versus 3% for in situ cancers in both studies. CONCLUSION: Addition of tomosynthesis to digital mammography offers the dual benefit of significantly increased diagnostic accuracy and significantly reduced recall rates for noncancer cases. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12120674/-/DC1.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mamografía/estadística & datos numéricos , Intensificación de Imagen Radiográfica/métodos , Técnica de Sustracción/estadística & datos numéricos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Femenino , Humanos , Variaciones Dependientes del Observador , Prevalencia , Reproducibilidad de los Resultados , Factores de Riesgo , Sensibilidad y Especificidad , Estados Unidos/epidemiología
11.
Eur J Radiol ; 82(2): 281-7, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23177185

RESUMEN

AIM: To evaluate the potential of SPECT myocardial perfusion imaging (MPI)-computed tomography coronary angiography (CTCA) hybrid fusion imaging to improve the diagnostic performance of cardiac SPECT/MPI and CTCA alone in order to act as more accurate gate keeper to further investigation invasive or not. METHODS AND RESULTS: Twenty-five patients were subjected to SPECT/MPI and CTCA within a period of 1 month without any medical treatment modification. A fusion software package was used for cardiac SPECT-CTCA image fusion. Semiquantitative analysis was performed for cardiac SPECT, CTCA and SPECT/MPI-CTCA fusion images. Patients were classified in 2 groups according to the clinical decision for further investigation (group A), or not (group B). Statistically significant differences were observed when SPECT/MPI-CTCA fusion images were used instead of cardiac SPECT alone (p<0.05). No statistically significant differences were observed comparing CTCA alone to SPECT/MPI-CTCA fusion images (p=0.25). A mid-term follow-up (mean 3.58 ± 0.24 years) showed that all patients classified in group A based on the interpretation of SPECT MPI-CTCA fused images underwent conventional coronary angiography with further necessity for PTCA or CABG whereas absence of major or minor cardiac events was revealed for all patients of group B. CONCLUSION: In patients suspected for coronary artery disease, cardiac SPECT/MPI-CTCA fusion imaging was found to considerably alter the clinical decision for referral to further investigation derived from SPECT/MPI.


Asunto(s)
Angiografía Coronaria/estadística & datos numéricos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Imagen de Perfusión Miocárdica/estadística & datos numéricos , Técnica de Sustracción/estadística & datos numéricos , Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Adulto , Anciano , Femenino , Grecia/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Reproducibilidad de los Resultados , Factores de Riesgo , Sensibilidad y Especificidad , Análisis de Supervivencia , Tasa de Supervivencia
13.
Eur J Radiol ; 81(5): 1002-6, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-21349672

RESUMEN

OBJECTIVES: To compare the diagnostic performances of computed tomography (CT), magnetic resonance (MR) imaging, and positron emission tomography (PET or PET/CT) for detection of metastatic lymph nodes in patients with ovarian cancer. METHODS: Relevant studies were identified with MEDLINE and EMBASE from January 1990 to July 2010. We estimated the weighted summary sensitivities, specificities, OR (odds ratio), and summary receiver operating characteristic (sROC) curves of each imaging technique and conducted pair-wise comparisons using the two-sample Z-test. Meta-regression, subgroup analysis, and funnel plots were also performed to explain the between-study heterogeneity. RESULTS: Eighteen eligible studies were included, with a total of 882 patients. PET or PET/CT was a more accurate modality (sensitivity, 73.2%; specificity, 96.7%; OR [odds ratio], 90.32). No significant difference was detected between CT (sensitivity, 42.6%; specificity, 95.0%; OR, 19.87) and MR imaging (sensitivity, 54.7%; specificity, 88.3%; OR, 12.38). Meta-regression analyses and subgroup analyses revealed no statistical difference. Funnel plots with marked asymmetry suggested a publication bias. CONCLUSION: FDG-PET or FDG-PET/CT is more accurate than CT and MR imaging in the detection of lymph node metastasis in patients with ovarian cancer.


Asunto(s)
Carcinoma/diagnóstico , Carcinoma/secundario , Imagen por Resonancia Magnética/estadística & datos numéricos , Neoplasias Ováricas/diagnóstico , Neoplasias Ováricas/epidemiología , Tomografía de Emisión de Positrones/estadística & datos numéricos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Carcinoma/epidemiología , Femenino , Humanos , Metástasis Linfática , Prevalencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Técnica de Sustracción/estadística & datos numéricos
14.
Eur J Radiol ; 81(5): 1007-15, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-21354739

RESUMEN

BACKGROUND AND PURPOSE: Lung cancer is the most common cause of cancer related death among both men and women worldwide. The skeleton is the most common site of cancer metastasis. Early detection is crucial for prognosis. To evaluate and compare the capability for bone metastasis assessment of [(18)F] fluoro-2-d-glucose positron emission tomography with computed tomography ((18)FDG-PET-CT), [(18)F] fluoro-2-d-glucose positron emission tomography ((18)FDG-PET), magnetic resonance imaging (MRI) and bone scintigraphy (BS) in lung cancer patients, a meta-analysis is preformed. METHODS: We searched MEDLINE, OVID, EMBASE and the Cochrane Library for studies evaluating diagnosis validity of (18)FDG-PET-CT, (18)FDG-PET, MRI and BS between January 1990 and August 2010. Meta-analysis methods were used to pool sensitivity, specificity, diagnostic odd ratios (DORs) and to construct a summary receiver-operating characteristic curve (SROC). RESULTS: A total of 17 articles (9 (18)FDG-PET-CT studies, 9 (18)FDG-PET studies, 6 MRI studies and 16 BS studies) that included 2940 patients who fulfilled all of the inclusion criteria were considered for inclusion in the analysis. The pooled sensitivity for the detection of bone metastasis in lung cancer using (18)FDG-PET-CT, (18)FDG-PET, MRI and BS were 0.92 (95% CI, 0.88-0.95), 0.87 (95% CI, 0.81-0.92), 0.77 (95% CI, 0.65-0.87) and 0.86 (95% CI, 0.82-0.89), respectively. The pooled specificity for the detection of bone metastasis from lung cancer using (18)FDG-PET-CT, (18)FDG-PET, MRI and BS were 0.98 (95% CI, 0.97-0.98), 0.94 (95% CI, 0.92-0.96), 0.92 (95% CI, 0.88-0.95), 0.88 (95% CI, 0.86-0.89), respectively. The pooled DORs estimates for (18)FDG-PET-CT 449.17 were significantly higher than for (18)FDG-PET (118.25, P<0.001), MRI (38.27, P<0.001) and BS (63.37, P<0.001). The pooled sensitivity of BS was not correlated with the prevalence of bone metastasis. CONCLUSION: The results showed that both (18)FDG-PET-CT and (18)FDG-PET were better imaging methods for diagnosing bone metastasis from lung cancer than MRI and BS. (18)FDG-PET-CT has higher diagnostic value (sensitivity, specificity and DORs) for diagnosing bone metastasis from lung cancer than any other imaging methods.


Asunto(s)
Neoplasias Óseas/diagnóstico , Neoplasias Óseas/secundario , Fluorodesoxiglucosa F18 , Neoplasias Pulmonares/diagnóstico , Imagen por Resonancia Magnética/estadística & datos numéricos , Tomografía de Emisión de Positrones/estadística & datos numéricos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Neoplasias Óseas/epidemiología , Femenino , Humanos , Neoplasias Pulmonares/epidemiología , Masculino , Prevalencia , Radiofármacos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Técnica de Sustracción/estadística & datos numéricos
15.
Eur J Radiol ; 81(2): 303-11, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21145680

RESUMEN

BACKGROUND AND PURPOSE: Evaluation of bone marrow infiltration is an essential step in the staging of lymphoma. The accuracy of (18)F-fluorodeoxyglucose-positron emission tomography ((18)F-FDG PET), combined (18)F-fluorodeoxyglucose-positron emission tomography/computed tomography ((18)F-FDG-PET/CT) and magnetic resonance imaging (MRI) in diagnosing bone marrow involvement of lymphoma has never been systematically assessed, and the present systematic review was aimed at this issue. METHODS: MEDLINE, EMBASE, Cochrane library and some other databases, from January 1995 to July 2010, were searched for initial studies. All the studies published in English or Chinese relating to the diagnostic value of (18)F-FDG PET, PET/CT and MRI for patients with bone marrow involvement of lymphoma were collected. We extracted data to calculate sensitivity, specificity, SROC curves and AUC and to test for heterogeneity. The statistic software called "Meta-Disc 1.4" was used for data analysis. RESULT: In 32 included studies, PET/CT had the highest pooled sensitivity, 91.6% (95%CI: 85.1, 95.9) and highest pooled specificity, 90.3% (95%CI: 85.9, 93.7). PET/CT also had the highest pooled DOR, 68.89 (95%CI: 15.88, 298.92). The AUC of PET, PET/CT, and MRI were 0.9430, 0.9505 and 0.8764. There was heterogeneity among studies and no evidence of publication bias. CONCLUSION: PET/CT was a highly sensitive and specific modality in diagnosing patients with bone marrow involvement in lymphoma. Compared with MRI and PET alone, PET/CT can play important roles in the staging of lymphoma.


Asunto(s)
Neoplasias de la Médula Ósea/epidemiología , Neoplasias de la Médula Ósea/patología , Linfoma/epidemiología , Linfoma/patología , Imagen por Resonancia Magnética/estadística & datos numéricos , Tomografía de Emisión de Positrones/estadística & datos numéricos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Comorbilidad , Femenino , Fluorodesoxiglucosa F18 , Humanos , Masculino , Estadificación de Neoplasias , Prevalencia , Radiofármacos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Técnica de Sustracción/estadística & datos numéricos
16.
Eur J Radiol ; 81(5): 1062-7, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-21382681

RESUMEN

PURPOSE: The purpose of this study is to evaluate the usefulness of a novel computerized method to select automatically the similar chest radiograph for image subtraction in the patients who have no previous chest radiographs and to assist the radiologists' interpretation by presenting the "similar subtraction image" from different patients. MATERIALS AND METHODS: Institutional review board approval was obtained, and the requirement for informed patient consent was waived. A large database of approximately 15,000 normal chest radiographs was used for searching similar images of different patients. One hundred images of candidates were selected according to two clinical parameters and similarity of the lung field in the target image. We used the correlation value of chest region in the 100 images for searching the most similar image. The similar subtraction images were obtained by subtracting the similar image selected from the target image. Thirty cases with lung nodules and 30 cases without lung nodules were used for an observer performance test. Four attending radiologists and four radiology residents participated in this observer performance test. RESULTS: The AUC for all radiologists increased significantly from 0.925 to 0.974 with the CAD (P=.004). When the computer output images were available, the average AUC for the residents was more improved (0.960 vs. 0.890) than for the attending radiologists (0.987 vs. 0.960). CONCLUSION: The novel computerized method for lung nodule detection using similar subtraction images from different patients would be useful to detect lung nodules on digital chest radiographs, especially for less experienced readers.


Asunto(s)
Reconocimiento de Normas Patrones Automatizadas/métodos , Intensificación de Imagen Radiográfica/métodos , Radiografía Torácica/estadística & datos numéricos , Nódulo Pulmonar Solitario/diagnóstico por imagen , Nódulo Pulmonar Solitario/epidemiología , Técnica de Sustracción/estadística & datos numéricos , Femenino , Humanos , Japón/epidemiología , Masculino , Prevalencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
Acad Radiol ; 19(1): 69-77, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22142679

RESUMEN

RATIONALE AND OBJECTIVES: Stage IV non-small-cell lung cancer (NSCLC) consists of a heterogeneous group of patients with different prognoses. We assessed the prognostic value of baseline whole body tumor burden as measured by metabolic tumor volume (MTV), total lesion glycolysis (TLG), and standardized uptake values (SUV(max) and SUV(mean)) of all tumors in nonsurgical patients with Stage IV NSCLC. MATERIALS AND METHODS: Ninety-two consecutive patients with newly diagnosed Stage IV NSCLC who had a pretreatment F-18 fludeoxyglucose positron emission tomography/computed tomography scan were retrospectively reviewed. The MTV, TLG, SUV(mean), and SUV(max) of whole-body (WB) tumors were measured with the MIMvista workstation with manual adjustment. RESULTS: There was a statistically significant association between overall survival (OS) and ln(MTV)/ln(TLG) at the level of WB tumor burden (MTV(WB)) and of primary tumor (MTV(T)). The hazard ratio (HR) for a 1-unit increase of ln(MTV(WB)) and ln(MTV(T)) before and after adjusting for age and gender was 1.48/1.48 (both P < .001) and 1.25/1.25 (P = .006, .007), respectively. The HR for a 1-unit increase of ln(TLG(WB)) and ln(TLG(T)) before and after adjusting for age and gender was 1.37/1.37 (both P = .001) and 1.19/1.19 (P = .001, .017), respectively. There was no statistically significant association between OS and ln(SUV(max)) and ln(SUV(mean)) at WB tumor burden, primary tumor, nodal metastasis, or distant metastasis (P > .05). There was low interobserver variability between two radiologists with concordance correlation coefficients of 0.90 for ln(MTV(WB)) and greater than 0.90 for SUV(maxWB), SUV(meanWB), and ln(TLG(WB)). CONCLUSION: Baseline WB metabolic tumor burden, as measured with MTV and TLG, is a prognostic measurement in patients within Stage IV NSCLC with low interobserver variability. This study also suggests pretreatment MTV and TLG measurements may be used to further stratify patients with Stage IV NSCLC and are better prognostic measures than SUV(max) and SUV(mean) measurements.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/mortalidad , Carcinoma de Pulmón de Células no Pequeñas/secundario , Fluorodesoxiglucosa F18 , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/mortalidad , Tomografía de Emisión de Positrones/estadística & datos numéricos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Anciano , Anciano de 80 o más Años , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico , Femenino , Fluorodesoxiglucosa F18/farmacocinética , Humanos , Illinois , Neoplasias Pulmonares/metabolismo , Masculino , Persona de Mediana Edad , Prevalencia , Pronóstico , Radiofármacos/farmacocinética , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Técnica de Sustracción/estadística & datos numéricos , Análisis de Supervivencia , Tasa de Supervivencia
18.
Skeletal Radiol ; 41(3): 249-56, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22072239

RESUMEN

OBJECTIVE: To systematically review and meta-analyse literature data on the diagnostic performance of fluorine-18-fluorodeoxyglucose (FDG) positron emission tomography (PET) and positron emission tomography/computed tomography (PET/CT) in patients with Ewing sarcoma family tumours (ESFT). MATERIALS AND METHODS: PubMed/MEDLINE, Embase and Scopus databases were searched for articles that evaluated FDG-PET and PET/CT in patients with ESFT from inception to 31 May 2011. Studies that fulfilled the three following criteria were included in the systematic review: FDG-PET or PET/CT performed in patients with ESFT; articles about the diagnostic accuracy of FDG-PET and PET/CT; sample size of at least 10 patients with ESFT were included. Studies in which there were sufficient data to reassess sensitivity and specificity of FDG-PET or PET/CT in ESFT were included in the meta-analysis, excluding duplicate publications. Finally, pooled sensitivity, pooled specificity and area under the receiver operating characteristic (ROC) curve of FDG-PET or PET/CT in ESFT were calculated. RESULTS: We found 13 studies comprising a total of 342 patients with ESFT. The main findings of the studies included are presented. The meta-analysis of five selected studies provided these results about FDG-PET and PET/CT in ESFT: pooled sensitivity: 96% (95% confidence interval [CI] 91-99%); pooled specificity: 92% (95% CI 87-96%); area under the ROC curve: 0.97. CONCLUSION: With regard to the staging and restaging of patients with ESFT, the sensitivity, specificity and accuracy of FDG-PET and PET/CT are high; the combination of FDG-PET or PET/CT with conventional imaging is a valuable tool for the staging and restaging of ESFT and has a relevant impact on the treatment strategy plan.


Asunto(s)
Neoplasias Óseas/diagnóstico , Neoplasias Óseas/epidemiología , Fluorodesoxiglucosa F18 , Tomografía de Emisión de Positrones/estadística & datos numéricos , Sarcoma de Ewing/diagnóstico , Sarcoma de Ewing/epidemiología , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Humanos , Prevalencia , Radiofármacos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Técnica de Sustracción/estadística & datos numéricos
19.
Med Phys ; 38(8): 4579-82, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21928630

RESUMEN

PURPOSE: To develop an automatic knot placement algorithm to enable the use of NonUniform Rational B-Splines (NURBS) in deformable image registration. METHODS: The authors developed a two-step approach to fit a known displacement vector field (DVF). An initial fit was made with uniform knot spacing. The error generated by this fit was then assigned as an attractive force pulling on the knots, acting against a resistive spring force in an iterative equilibration scheme. To demonstrate the accuracy gain of knot optimization over uniform knot placement, we compared the sum of the squared errors and the frequency of large errors. RESULTS: Fits were made to a one-dimensional DVF using 1-20 free knots. Given the same number of free knots, the optimized, nonuniform B-spline fit produced a smaller error than the uniform B-spline fit. The accuracy was improved by a mean factor of 4.02. The optimized B-spline was found to greatly reduce the number of errors more than 1 standard deviation from the mean error of the uniform fit. The uniform B-spline had 15 such errors, while the optimized B-spline had only two. The algorithm was extended to fit a two-dimensional DVF using control point grid sizes ranging from 8 x 8 to 15 x 15. Compared with uniform fits, the optimized B-spline fits were again found to reduce the sum of squared errors (mean ratio = 2.61) and number of large errors (mean ratio = 4.50). CONCLUSIONS: Nonuniform B-splines offer an attractive alternative to uniform B-splines in modeling the DVF. They carry forward the mathematical compactness of B-splines while simultaneously introducing new degrees of freedom. The increased adaptability of knot placement gained from the generalization to NURBS offers increased local control as well as the ability to explicitly represent topological discontinuities.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/estadística & datos numéricos , Algoritmos , Fenómenos Biofísicos , Humanos , Movimiento , Técnica de Sustracción/estadística & datos numéricos
20.
Adv Exp Med Biol ; 696: 441-9, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21431584

RESUMEN

Medical image fusion has been used to derive the useful complimentary information from multimodal images. The prior step of fusion is registration or proper alignment of test images for accurate extraction of detail information. For this purpose, the images to be fused are geometrically aligned using mutual information (MI) as similarity measuring metric followed by genetic algorithm to maximize MI. The proposed fusion strategy incorporating multi-resolution approach extracts more fine details from the test images and improves the quality of composite fused image. The proposed fusion approach is independent of any manual marking or knowledge of fiducial points and starts the procedure automatically. The performance of proposed genetic-based fusion methodology is compared with fuzzy clustering algorithm-based fusion approach, and the experimental results show that genetic-based fusion technique improves the quality of the fused image significantly over the fuzzy approaches.


Asunto(s)
Algoritmos , Diagnóstico por Imagen/estadística & datos numéricos , Interpretación de Imagen Asistida por Computador/métodos , Encéfalo/anatomía & histología , Encéfalo/diagnóstico por imagen , Análisis por Conglomerados , Biología Computacional , Lógica Difusa , Humanos , Imagen por Resonancia Magnética/estadística & datos numéricos , Técnica de Sustracción/estadística & datos numéricos , Tomografía Computarizada por Rayos X/estadística & datos numéricos
SELECCIÓN DE REFERENCIAS