1.
J Thromb Haemost ; 16(10): 2050-2056, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30007048

RESUMEN

Essentials ClotChip is a novel microsensor for comprehensive assessment of ex vivo hemostasis. Clinical samples show high sensitivity to detecting the entire hemostatic process. ClotChip readout exhibits distinct information on coagulation factor and platelet abnormalities. ClotChip has potential as a point-of-care platform for comprehensive hemostatic analysis. SUMMARY: Background Rapid point-of-care (POC) assessment of hemostasis is clinically important in patients with a variety of coagulation factor and platelet defects who have bleeding disorders. Objective To evaluate a novel dielectric microsensor, termed ClotChip, which is based on the electrical technique of dielectric spectroscopy for rapid, comprehensive assessment of whole blood coagulation. Methods The ClotChip is a three-dimensional, parallel-plate, capacitive sensor integrated into a single-use microfluidic channel with miniscule sample volume (< 10 µL). The ClotChip readout is defined as the temporal variation in the real part of dielectric permittivity of whole blood at 1 MHz. Results The ClotChip readout exhibits two distinct parameters, namely, the time to reach a permittivity peak (Tpeak ) and the maximum change in permittivity after the peak (Δεr,max ), which are, respectively, sensitive towards detecting non-cellular (i.e. coagulation factor) and cellular (i.e. platelet) abnormalities in the hemostatic process. We evaluated the performance of ClotChip using clinical blood samples from 15 healthy volunteers and 12 patients suffering from coagulation defects. The ClotChip Tpeak parameter exhibited superior sensitivity at distinguishing coagulation disorders as compared with conventional screening coagulation tests. Moreover, the ClotChip Δεr,max parameter detected platelet function inhibition induced by aspirin and exhibited strong positive correlation with light transmission aggregometry. Conclusions This study demonstrates that ClotChip assesses multiple aspects of the hemostatic process in whole blood on a single disposable cartridge, highlighting its potential as a POC platform for rapid, comprehensive hemostatic analysis.


Asunto(s)
Trastornos de la Coagulación Sanguínea/diagnóstico , Coagulación Sanguínea , Dispositivos Laboratorio en un Chip , Técnicas Analíticas Microfluídicas/instrumentación , Pruebas en el Punto de Atención , Transductores , Tiempo de Coagulación de la Sangre Total/instrumentación , Aspirina/farmacología , Trastornos de la Coagulación Sanguínea/sangre , Factores de Coagulación Sanguínea/metabolismo , Estudios de Casos y Controles , Espectroscopía Dieléctrica , Diseño de Equipo , Humanos , Agregación Plaquetaria/efectos de los fármacos , Inhibidores de Agregación Plaquetaria/farmacología , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
2.
J Int Med Res ; 46(2): 873-882, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28974132

RESUMEN

Objective This study compared the activated clotting time (ACT) measured using the Hemochron Jr. Signature (HACT) with the ACT measured using the Medtronic ACT Plus (MACT) during cardiopulmonary bypass (CPB) with acute normovolemic haemodilution (ANH) in patients undergoing cardiac surgery. Methods The ACT was checked at baseline with both devices after inducing anaesthesia, and 400 to 800 mL of whole blood was withdrawn to induce moderate ANH. Before initiating CPB, a 300-IU/kg bolus dose of heparin was administered to maintain the HACT at >400 s; protamine was later given to reverse the anticoagulation. The ACT was checked using both devices at baseline, during heparinisation, and after protamine administration. Results In total, 106 pairs of samples from 29 patients were analysed. The ACT showed a good correlation between the two devices (r = 0.956). However, Bland-Altman analysis showed that the MACT was higher, particularly at baseline and during heparinisation. Multiple regression analysis showed that the blood glucose concentration significantly influenced the differences between the two ACT devices. Conclusions The HACT was lower than the MACT during CPB with ANH in patients undergoing cardiac surgery. Clinicians should be cautious when using each ACT device within generally accepted reference ACT values.


Asunto(s)
Automatización de Laboratorios/instrumentación , Puente Cardiopulmonar , Hemodilución/métodos , Flebotomía/métodos , Tiempo de Coagulación de la Sangre Total/instrumentación , Anciano , Anestesia General , Anticoagulantes/uso terapéutico , Artefactos , Automatización de Laboratorios/normas , Glucemia/metabolismo , Viscosidad Sanguínea , Femenino , Heparina/uso terapéutico , Antagonistas de Heparina/uso terapéutico , Humanos , Masculino , Persona de Mediana Edad , Protaminas/uso terapéutico , Análisis de Regresión , Tiempo de Coagulación de la Sangre Total/normas
3.
Ann Biol Clin (Paris) ; 73(2): 225-54, 2015.
Artículo en Francés | MEDLINE | ID: mdl-25847747

RESUMEN

Point of care testing (POCT) must comply with regulatory requirements according to standard EN ISO 22870, which identify biologists as responsible for POCT. Activated clotting time (ACT) is mandatory to monitor on whole blood, anticoagulation achieved by unfractionated heparin during cardiopulmonary bypass (CPB) or cardiac catheterization. This test has no equivalent in the laboratory. With the aim to help the multidisciplinary groups for POCT supervision when they have to analyse the wish of medical departments to use ACT and to help the biologists to be in accordance with the standard, we present the guidelines of the GEHT (Groupe d'étude d'hémostase et thrombose) subcommittee "CEC et Biologie délocalisée" for the certification of ACT. These guidelines are based on the SFBC guidelines for the certification of POCT and on the analysis of the literature to ascertain the justification of clinical need and assess the analytical performance of main analyzers used in France, as well as on a survey conducted with French and Belgian biologists.


Asunto(s)
Coagulación Sanguínea , Certificación , Monitoreo Intraoperatorio/métodos , Monitoreo Intraoperatorio/normas , Trombosis/sangre , Acreditación , Procedimientos Quirúrgicos Cardíacos/instrumentación , Procedimientos Quirúrgicos Cardíacos/métodos , Procedimientos Quirúrgicos Cardíacos/normas , Francia , Hemostasis , Humanos , Monitoreo Intraoperatorio/instrumentación , Estándares de Referencia , Trombosis/diagnóstico , Tiempo de Coagulación de la Sangre Total/instrumentación , Tiempo de Coagulación de la Sangre Total/normas
4.
Nephrol Dial Transplant ; 29(5): 1092-6, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24366900

RESUMEN

BACKGROUND: During haemodialysis, anticoagulants are required to prevent clotting in the extracorporeal circuit. Low-molecular weight heparins (LMWH) are frequently used because of the ease of a single injection at the start of dialysis. Disadvantages of LMWH include the lack of a reliable bedside assay for measuring their anticoagulant effect. METHODS: We investigated a bedside test for LMWH activity. The relationship between anti-Xa (chromogenic assay) and Hemonox point-of-care assay was evaluated in 21 dialysis patients (12 men and 9 women) with a median age of 71 years, receiving tinzaparin at the start of a haemodiafiltration session. RESULTS: At the start, before tinzaparin administration, median (interquartile ranges) of Hemonox values were 74 (67-82) s. Thirty minutes after tinzaparin administration, Hemonox values were increased to 496 (360-736) s, followed by a decrease to 149 (135-301) s after 120 min, 102 (97-144) s after 180 min and 92 (83-100) s after 240 min. Corresponding anti-Xa activities were 0 (0-0), 1.12 (0.9-1.29), 0.74 (0.57-0.96), 0.47 (0.31-0.7) and 0.31(0.16-0.49) IU/mL. Hemonox values showed an exponential relation to anti-Xa levels. Interchangeability of tests was shown by Bland-Altman plot. CONCLUSION: Point-of-care Hemonox test is a valuable bedside method for monitoring anti-Xa activity in dialysis patients anticoagulated with tinzaparin.


Asunto(s)
Anticoagulantes/uso terapéutico , Fibrinolíticos/uso terapéutico , Heparina de Bajo-Peso-Molecular/uso terapéutico , Monitoreo Fisiológico , Sistemas de Atención de Punto , Diálisis Renal , Tiempo de Coagulación de la Sangre Total/métodos , Anciano , Anciano de 80 o más Años , Coagulación Sanguínea/efectos de los fármacos , Enfermedad Crónica , Inhibidores del Factor Xa , Femenino , Humanos , Masculino , Persona de Mediana Edad , Curva ROC , Tinzaparina , Tiempo de Coagulación de la Sangre Total/instrumentación
7.
Asian Cardiovasc Thorac Ann ; 20(5): 544-7, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23087297

RESUMEN

BACKGROUND: This study aimed to compare preoperative baseline Sonoclot variables between acyanotic and cyanotic congenital heart disease patients. METHODS: 100 patients aged from infancy to 9-years were studied. Fifty patients each from the cyanotic and acyanotic groups were studied for Sonoclot parameters preoperatively. After inhalational anesthetic induction, blood was collected from the arterial line and analyzed in a Sonoclot analyzer to measure Sonoclot activated coagulation time, clot rate, and platelet function. RESULTS: Sonoclot activated coagulation time was normal in both groups, but lower in the cyanotic group (127.95 ± 51.4 s) than the acyanotic group (147.85 ± 45.48 s; p = 0.54). Both groups had abnormal clot rates and platelet function. The clot rate was significantly lower in the cyanotic group (19.31 ± 10.68 U·min(-1)) than acyanotic group (24.88 ± 9.23 U·min(-1); p = 0.009). Platelet function was deranged in 31% of patients (cyanotic, 59%; acyanotic, 8%; p <0.001). Platelet function was the most severely affected baseline parameter. CONCLUSIONS: Pediatric acyanotic and cyanotic congenital heart disease patients have deranged coagulation parameters as assessed by the Sonoclot analyzer. The abnormality is more marked in cyanotic patients. Platelet function is the most severely affected parameter. These baseline parameters in conjunction with post-bypass parameters for an individual patient will help in the formulation of specific blood component transfusion guidelines.


Asunto(s)
Trastornos de la Coagulación Sanguínea/diagnóstico , Coagulación Sanguínea , Cardiopatías Congénitas/sangre , Sistemas de Atención de Punto , Tiempo de Coagulación de la Sangre Total/instrumentación , Trastornos de la Coagulación Sanguínea/sangre , Trastornos de la Coagulación Sanguínea/complicaciones , Procedimientos Quirúrgicos Cardíacos , Distribución de Chi-Cuadrado , Niño , Preescolar , Cianosis/sangre , Cianosis/etiología , Elasticidad , Femenino , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/cirugía , Humanos , Lactante , Recién Nacido , Masculino , Pruebas de Función Plaquetaria , Valor Predictivo de las Pruebas , Estudios Prospectivos , Viscosidad
8.
J Extra Corpor Technol ; 44(1): 15-20, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22730859

RESUMEN

This study compares four different activated clotting time (ACT) point-of-care (POC) testing systems used at our institution for the management of patients undergoing heparin therapy. We evaluated these systems under identical conditions to determine their accuracy, reproducibility, ease of use, and cost. Two separate testing stations containing four ACT systems were used. The testing order was randomized for every sample and performed by two trained individuals. Samples of fresh heparinized whole blood were taken at regular intervals and distributed to each station. Each operator tested 50 samples, totaling 400 ACT tests. The ACT value was significantly affected by the type of machine used at both stations 1 and 2 (p < .001). Compared with all systems, the Medtronic ACT Plus Automated Coagulation Timer System (ACT Plus) resulted in the most consistent ACT values (median = 171, Interquartile Range (IQR): 169-175) and least variability (172.17 +/- 5.24). The Hemochron Signature Elite Whole Blood Microcoagulation System had the most variability (221.10 +/- 14.78) and yielded consistently higher ACT values (median = 220, IQR: 210-229.5) compared with other systems. The ACT values reported by the i-STAT Handheld and Test Cartridge Blood Analysis System (153.30 +/- 7.87) were consistently lower (median = 154, IQR: 147-161) in comparison to the ACT Plus and Medtronic HMS Plus Hemostasis Management System (180.60 +/- 7.60, median = 181, IQR: 175-186). There was no statistical difference in results between the two testing sites (p > .05) or the operators (p > .05). The significant finding of this study was the affect each system has on the ACT value. This investigation demonstrates the variability that exists among different ACT monitoring systems at our institution. The discrepant variation in ACT values that exists with the Hemochron system questions the reliability of its use in the management of patients undergoing heparin therapy.


Asunto(s)
Coagulación Sanguínea/efectos de los fármacos , Coagulación Sanguínea/fisiología , Monitoreo de Drogas/instrumentación , Heparina/farmacología , Sistemas de Atención de Punto , Tiempo de Coagulación de la Sangre Total/instrumentación , Anticoagulantes/farmacología , Niño , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
9.
Anesth Analg ; 115(2): 244-52, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22584552

RESUMEN

BACKGROUND: The activated clotting time (ACT) is widely used for monitoring heparin anticoagulation during cardiac surgery. Celite-based ACT values are prolonged when aprotinin is administered. MDCO-2010, a novel serine protease inhibitor, is currently being evaluated as a possible alternative to aprotinin. Therefore, we evaluated the in vitro effects of this novel agent on ACT values using 3 different point-of-care instruments with kaolin or celite as an activator. METHODS: The study was performed in 2 parts. In the first part, blood samples were obtained from 15 healthy volunteers. Samples were pipetted into small Eppendorf tubes and 2 concentrations of the MDCO-2010 (100 and 500 nM, final concentration) alone or with heparin (1.2 or 2.4 U/mL) were added. ACTs were measured using Helena (celite), Hemochron (kaolin), and Medtronic (kaolin) devices. In the second part of the study, blood samples were obtained intraoperatively, at 5 time points, from 15 patients undergoing cardiopulmonary bypass. MDCO-2010 at a final concentration of 100 or 500 nM was added and ACT testing was performed as before. Additional coagulation tests included prothrombin time, activated partial thromboplastin time, fibrinogen, antithrombin, prothrombin, and anti-Xa levels. RESULTS: Addition of MDCO-2010 concentration-dependently prolonged ACTs in volunteers' and patients' blood samples regardless of the ACT activator or device used. In volunteer samples (no heparin) and in patient samples (baseline and intensive care unit) percent changes in ACTs due to MDCO-2010 were on average 3.1 ± 1.8 times higher (95% confidence interval 2.6-3.6; P < 0.001) for the celite-based Helena device compared with either Hemochron or Medtronic devices. CONCLUSION: MDCO-2010 causes less ACT prolongation with kaolin than with celite activation.


Asunto(s)
Anticoagulantes/farmacología , Antifibrinolíticos/farmacología , Coagulación Sanguínea/efectos de los fármacos , Procedimientos Quirúrgicos Cardíacos , Heparina/farmacología , Inhibidores de Serina Proteinasa/farmacología , Tiempo de Coagulación de la Sangre Total , Adulto , Anciano , Anticoagulantes/efectos adversos , Antifibrinolíticos/efectos adversos , Puente Cardiopulmonar , Tierra de Diatomeas , Relación Dosis-Respuesta a Droga , Interacciones Farmacológicas , Monitoreo de Drogas/métodos , Femenino , Heparina/efectos adversos , Humanos , Caolín , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio/métodos , Sistemas de Atención de Punto , Valor Predictivo de las Pruebas , Inhibidores de Serina Proteinasa/efectos adversos , Factores de Tiempo , Tiempo de Coagulación de la Sangre Total/instrumentación
11.
J Biomed Opt ; 16(5): 057001, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21639579

RESUMEN

We report a new technique to measure coagulation dynamics on whole-blood samples. The method relies on the analysis of the speckle figure resulting from a whole-blood sample mixed with coagulation reagent and introduced in a thin chamber illuminated with a coherent light. A dynamic study of the speckle reveals a typical behavior due to coagulation. We compare our measured coagulation times to a reference method obtained in a medical laboratory.


Asunto(s)
Coagulación Sanguínea/fisiología , Rayos Láser , Fotometría/instrumentación , Refractometría/instrumentación , Tiempo de Coagulación de la Sangre Total/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Luz , Dispersión de Radiación
12.
Am J Clin Pathol ; 135(5): 741-8, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21502428

RESUMEN

Historically, it has been difficult for hospitals to change methods for activated clotting time (ACT) testing because of differences in ACT values obtained with different instruments, wide differences in target ranges used in different procedures, and the difficulty of performing crossover studies at the bedside in critical care situations. There are limited published data comparing the i-STAT (Abbott Point of Care, Princeton, NJ) kaolin ACT with the Medtronic ACT Plus (Medtronic, Minneapolis, MN). The i-STAT system can perform ACT testing in addition to testing of a number of critical care analytes and may offer potential advantages over other ACT analyzers. Comparison of ACT values on 121 simultaneous split-sample tests yielded an R(2) of 0.88 with i-STAT = 0.79 Medtronic + 72.0. The Pearson correlation was R = 0.94, indicating statistically significant correlation between the 2 methods. Based on this comparison, we were able to implement the i-STAT ACT throughout our institution without changing target ranges for any individual procedure.


Asunto(s)
Tiempo de Coagulación de la Sangre Total/normas , Centros Médicos Académicos , Coagulación Sanguínea , Procedimientos Quirúrgicos Cardiovasculares , Tierra de Diatomeas , Humanos , Caolín , Valores de Referencia , Tiempo de Coagulación de la Sangre Total/instrumentación
13.
Anesth Analg ; 113(1): 31-9, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21519054

RESUMEN

BACKGROUND: Acquired platelet dysfunction due to aspirin ingestion may increase bleeding tendency during surgery. Thus, we examined the diagnostic accuracy of in vivo bleeding time (BT) and 2 platelet function assays for the preoperative assessment of a residual antiplatelet effect in patients treated with aspirin. METHODS: Consecutive patients scheduled for surgery were prospectively enrolled in this study. The patients' last aspirin ingestion had occurred within the previous 48 hours before blood sampling in the "full aspirin effect" group, between 48 and 96 hours before in the "variable aspirin effect" group, and >96 hours before in the "recovered aspirin effect" group. The control group had not taken any aspirin. Multiple electrode aggregometry, platelet function analyzer (PFA)-100, and in vivo BT were performed to assess the effects of aspirin. One-way analysis of variance on ranks with a post hoc multiple-comparison procedure (Dunn) was used to detect differences among the groups. Categorical data were compared using the z test. Receiver operating characteristic (ROC) curves were created to determine the diagnostic accuracy of the platelet function assays investigated. The area under the ROC curve (AUC), sensitivity, and specificity of the assays were calculated. The level of statistical significance was set at P < 0.05. RESULTS: Three hundred ninety-four patients were included in the analysis (133 control and 261 aspirin-treated patients). All 3 methods were able to detect the antiplatelet effect of aspirin in the full aspirin effect group. Furthermore, no difference in the measurement values between the recovered aspirin effect and control group was found, irrespective of the assay performed. Measurement values in the variable aspirin effect group were different from those of the control group in the ASPItest using multiple electrode aggregometry and COL-EPI using PFA-100 but not in BT. ROC analysis showed the highest diagnostic accuracy in excluding the residual aspirin effect in the ASPItest (AUC 0.81, P < 0.001), followed by COL-EPI (AUC 0.78, P < 0.001) and BT (AUC 0.56, P = 0.05). The cutoff value of 53 U in the ASPItest excluded the effect of aspirin with a sensitivity of 88% and specificity of 71%. CONCLUSIONS: The full therapeutic antiplatelet effects of aspirin can be expected within 48 hours of the patient's last aspirin ingestion. Platelet function recovered in our study if aspirin cessation occurred >96 hours (4 days) before; thus, in these patients, preoperative platelet function testing is not useful. To quantify any residual aspirin effect in patients who ceased their intake of aspirin between 48 and 96 hours before surgery, the ASPItest might have the highest diagnostic accuracy.


Asunto(s)
Aspirina/efectos adversos , Tiempo de Sangría/métodos , Plaquetas/efectos de los fármacos , Sistemas de Atención de Punto , Cuidados Preoperatorios/métodos , Tiempo de Coagulación de la Sangre Total/métodos , Adulto , Anciano , Tiempo de Sangría/instrumentación , Plaquetas/fisiología , Electrodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/efectos adversos , Recuento de Plaquetas/instrumentación , Recuento de Plaquetas/métodos , Cuidados Preoperatorios/instrumentación , Estudios Prospectivos , Tiempo de Coagulación de la Sangre Total/instrumentación
14.
J Cardiothorac Vasc Anesth ; 25(3): 395-401, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21376632

RESUMEN

OBJECTIVE: To compare the activated coagulation times (ACTs) measured with the blood-saving kaolin i-STAT 1 ACT technique (Abbott Point of Care Inc, Princeton, NJ) with ACTs obtained from the widely used ACTR II device (Medtronic, Inc, Minneapolis, MN) in children undergoing cardiac surgery. DESIGN: A prospective, observational single-center study. PARTICIPANTS: Forty-four pediatric cardiac surgery patients. INTERVENTION: Surgery was performed with cardiopulmonary bypass (CPB) necessitating heparinization. METHODS AND MAIN RESULTS: ACTs measured on the i-STAT 1 device (2 × 95 µL) were compared with those obtained from the Medtronic ACTR II device (2 × 0.5 mL). Blood samples were drawn before, during, and after heparinization for CPB and paired for statistical analysis. The 2 techniques were compared using simple and multiregression analyses and the Bland-Altman method. In total, 179 intrarater and 142 interrater data pairs were analyzed. The intrarater reliability of the 2 devices was good, with a mean bias and limits of agreement of +2.0 and -55.5/+59.5 seconds for the Medtronic ACTR II and +0.5 and -59.9/+60.9 seconds for the i-STAT 1. An interrater reliability analysis of the mean of simultaneously measured ACT of the Medtronic ACTR II and both i-STAT 1 devices yielded a mean bias of -5.3 seconds and limits of agreement of -210.1/+199.5 seconds. A comparison of the higher of the paired ACT values from both devices showed similar results. After the removal of heparin, the i-STAT 1's ACT values became significantly lower than those measured on the Medtronic ACTR II (p < 0.001). Simple and multiregression analyses revealed that base excess independently influenced the mean bias of the ACT values from the Medtronic ACTR II (p = 0.037) and i-STAT 1 devices (p = 0.036). CONCLUSION: The kaolin i-STAT 1 ACT technique agreed well with the Medtronic ACTR II technique during the nonheparinized phase that preceded CPB. The overall agreement between the ACT obtained from the 2 devices was poor. The routine use of i-STAT 1 measured ACT values cannot be recommended as a reliable alternative to the Medtronic ACTR II.


Asunto(s)
Anestesia/normas , Coagulación Sanguínea , Puente Cardiopulmonar/normas , Monitoreo Intraoperatorio/normas , Tiempo de Coagulación de la Sangre Total/normas , Adolescente , Factores de Edad , Anestesia/métodos , Procedimientos Quirúrgicos Cardíacos/normas , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Monitoreo Intraoperatorio/instrumentación , Monitoreo Intraoperatorio/métodos , Tiempo de Tromboplastina Parcial/instrumentación , Tiempo de Tromboplastina Parcial/métodos , Tiempo de Tromboplastina Parcial/normas , Estudios Prospectivos , Tiempo de Coagulación de la Sangre Total/instrumentación , Tiempo de Coagulación de la Sangre Total/métodos
15.
Technol Health Care ; 19(2): 109-14, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21422535

RESUMEN

Since heparin has been in use as an anticoagulant during vascular surgery and medical problems such as DVT or pulmonary embolism, there has been no consensus as to the best method of monitoring its effect on anticoagulation. In this study we used Sonoclot Analyzer to detect hemostasis changes resulting from heparin administration. The study involved 16 randomly selected male patients undergoing peripheral reconstructive surgery. Blood samples were drawn and analyzed in the operating room on the Sonoclot Coagulation and Platelet Function Analyzer. Results showed that patients respond to heparin differently. The Sonoclot monitors the hemodynamics of blood using four variables: SonACT (activated clotting time) time, rate, peak, and contraction rate. Heparin has three effective on the Sonoclot Signature; prolonged ACT result, lower clot rate, and reduction in clot retraction. The SonACT time is the time for first fibrin to form. Prolong this time indicates the presence of anticoagulation. The Sonoclot Analyzer results confirm that it is a reliable and sensitive device for monitoring heparinization levels.


Asunto(s)
Heparina/uso terapéutico , Enfermedad Arterial Periférica/cirugía , Trombofilia/prevención & control , Tiempo de Coagulación de la Sangre Total/instrumentación , Anciano , Anticoagulantes/efectos adversos , Anticoagulantes/uso terapéutico , Hemostasis/fisiología , Heparina/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Sistemas de Atención de Punto , Complicaciones Posoperatorias/prevención & control , Procedimientos de Cirugía Plástica , Trombofilia/complicaciones , Trombofilia/diagnóstico , Procedimientos Quirúrgicos Vasculares
16.
Anesth Analg ; 111(1): 173-9, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20519414

RESUMEN

BACKGROUND: Monitoring heparin concentration along with the activated clotting time (ACT) may provide a more accurate guide for the administration of heparin to infants during cardiopulmonary bypass (CPB). However, standard laboratory assays of heparin concentration (antifactor Xa heparin concentration) require plasma instead of whole blood, and results are not immediately available to clinicians. Alternatively, measurements of whole blood heparin concentration may be performed at the bedside using an automated protamine titration device, the Hepcon instrument (Hepcon Hemostasis Management System Plus; Medtronics, Minneapolis, MN). The purpose of this investigation was to compare ACT measurements from 3 commercially available instruments and bedside measurements of whole blood heparin concentration using the Hepcon instrument with laboratory measurements of antifactor Xa plasma heparin concentration in infants younger than 6 months of age undergoing CPB. METHODS: Forty-four pediatric patients younger than 6 months of age scheduled for elective cardiac surgery requiring CPB were enrolled in this prospective study. Blood samples were drawn 3 minutes after the initial heparin bolus and immediately before the termination of CPB to obtain measurements of heparin anticoagulation. Kaolin-activated ACTs were performed with the Hemochron (International Technidyne Corporation, Edison, NJ), Hepcon, and i-STAT (i-STAT Corporation, East Windsor, NJ) instruments. Whole blood heparin concentration was measured using the Hepcon instrument. Plasma heparin concentration was measured using an antifactor Xa chromogenic substrate assay. RESULTS: Immediately after the initial heparin bolus, none of the ACT values correlated with plasma heparin concentration. When measured immediately before the termination of CPB, only the i-STAT ACT showed a moderate correlation. Conversely, bedside measurements of whole blood heparin concentration showed satisfactory agreement with laboratory measurements of plasma heparin concentration at both time points (concordance correlation coefficients 0.30 and 0.67, respectively). There is a bias in that antifactor Xa-measured plasma heparin concentration tends to be higher than Hepcon-measured whole blood heparin concentration. CONCLUSIONS: In infants younger than 6 months old undergoing CPB, caution is warranted when using ACT values as the sole indication of adequate heparin anticoagulation. In general, ACT prolongation correlates poorly with plasma heparin concentration. Only i-STAT ACT values showed a moderate correlation when measured immediately before the termination of CPB. Alternatively, bedside measurements of whole blood heparin concentration measured by the Hepcon instrument agreed well with antifactor Xa laboratory measurements. Our data support the clinical utility of bedside measurements of heparin concentration to provide timely, convenient, and accurate measurements of heparin concentration in these infants.


Asunto(s)
Anticoagulantes/sangre , Coagulación Sanguínea/efectos de los fármacos , Puente Cardiopulmonar , Heparina/sangre , Tiempo de Coagulación de la Sangre Total , Anticoagulantes/farmacología , Procedimientos Quirúrgicos Cardíacos , Relación Dosis-Respuesta a Droga , Factor Xa/metabolismo , Femenino , Heparina/farmacología , Humanos , Lactante , Recién Nacido , Masculino , Sistemas de Atención de Punto , Tetralogía de Fallot/cirugía , Tiempo de Coagulación de la Sangre Total/instrumentación
17.
J Extra Corpor Technol ; 40(3): 193-5, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18853832

RESUMEN

Activating clotting time (ACT) is a point-of-care, blood clotting test used to monitor anticoagulation. Recently, institutional requirements have required that ACT testing be completed outside the operating room with trained, certified personnel other than anesthesia staff. For this reason, in this study, we looked at whether a delay in processing an ACT makes a significant difference to the ACT results. Twenty patients between 18 and 65 years of age consented to the study, each undergoing non-cardiac surgery, with no intraoperative administration of heparin. The study was approved by our Institutional Review Board. A blood sample was taken from the patient's arterial line in the operating room. Immediately afterward, 1 mL was placed into each of two ACT cartridges and the measurement was done in a Medtronic ACT2 machine. The first ACT value was 126.9 +/- 14.5 seconds. The ACT value at approximately 30 minutes was 108.3 +/- 20.3 seconds (p < .0001). The time between the first and last measurements was 29.4 +/- 3.0 minutes. The results suggest that the ACT values decrease over time between sampling all measurements. At approximately 30 minutes, the ACT values average 15% less than the control measurements. Therefore, it would seem prudent to determine ACT values immediately in the operating room without any delay, using point-of-care testing.


Asunto(s)
Coagulación Sanguínea/fisiología , Tiempo de Coagulación de la Sangre Total/instrumentación , Tiempo de Coagulación de la Sangre Total/métodos , Coagulación Sanguínea/efectos de los fármacos , Diseño de Equipo , Análisis de Falla de Equipo , Heparina/farmacología , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Factores de Tiempo
18.
J Cardiothorac Vasc Anesth ; 22(1): 47-52, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18249330

RESUMEN

OBJECTIVE: The inadequacy of heparinization during cardiopulmonary bypass (CPB) can lead to hemostatic activation with increases in postoperative blood loss and blood product requirements after cardiac surgery. Because activated coagulation time (ACT) measurements may not be accurate during CPB, the use of a heparin management system (HMS) has been advocated. This study compared the efficacy of a modified ACT-based system versus an HMS (Hepcon; Medtronic Inc, Minneapolis, MN) for CPB anticoagulation. DESIGN: Randomized controlled trial. SETTING: Regional cardiac surgery center. PARTICIPANTS: Adult elective cardiac surgical patients. INTERVENTIONS: Patients allocated to the HMS group (HC) received individualized heparin doses as indicated by the Hepcon system. Patients in the modified ACT group (C) received a standard weight-based heparin bolus with further doses as dictated by the ACT (Max-ACT, Helena Labs, Sunderland, UK). In addition, group C received supplemental heparin, independent of the ACT, as dictated by the volume of crystalloid added to the extracorporeal circuit. Outcome measures examined were hemostatic activation, postoperative chest tube loss, and blood product requirements. RESULTS: This study showed no significant difference in efficacy between the modified ACT and HMS heparinization strategies. Although the HC group received significantly greater amounts of heparin, this did not reduce hemostatic activation, postoperative blood loss, or transfusion requirements. CONCLUSION: ACT-based heparinization was found to be as efficacious as the Hepcon HMS system.


Asunto(s)
Anticoagulantes/administración & dosificación , Coagulación Sanguínea/efectos de los fármacos , Puente Cardiopulmonar , Heparina/administración & dosificación , Tromboelastografía/efectos de los fármacos , Tiempo de Coagulación de la Sangre Total/métodos , Anciano , Anticoagulantes/efectos adversos , Coagulación Sanguínea/fisiología , Relación Dosis-Respuesta a Droga , Diseño de Equipo , Femenino , Hemostasis/efectos de los fármacos , Heparina/efectos adversos , Antagonistas de Heparina/administración & dosificación , Antagonistas de Heparina/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Protaminas/administración & dosificación , Protaminas/efectos adversos , Factores de Tiempo , Tiempo de Coagulación de la Sangre Total/instrumentación
19.
J Extra Corpor Technol ; 40(4): 271-4, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19192757

RESUMEN

Modern management of extracorporeal circulation, especially during long-term support of post-cardiac surgical patients, remains challenging and requires optimal care of the patient's fluid balance and coagulation hemostasis for its successful outcome. The activated clotting time assay is one of the tests used to manage extracorporeal circulation and is available in a low- and high-range level. The question of which assay is more appropriate for procedures that require low to moderate heparin dosing is still unclear. We report our experience with a neonate diagnosed with hypoplastic left heart syndrome who needed emergent extracorporeal membrane oxygenation support for 13 days after Norwood stage I palliation using a Sano shunt. Although successful, bleeding complications prompted us to review our strategy for management of coagulation hemostasis.


Asunto(s)
Anticoagulantes/uso terapéutico , Coagulación Sanguínea/efectos de los fármacos , Puente Cardiopulmonar/efectos adversos , Heparina/uso terapéutico , Tiempo de Coagulación de la Sangre Total/instrumentación , Circulación Extracorporea/instrumentación , Circulación Extracorporea/métodos , Femenino , Humanos , Recién Nacido , Hemorragia Posparto/prevención & control , Tromboelastografía/instrumentación , Tromboelastografía/métodos , Factores de Tiempo , Tiempo de Coagulación de la Sangre Total/métodos
20.
Blood Coagul Fibrinolysis ; 18(7): 619-22, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17890948

RESUMEN

Fondaparinux is a new anticoagulant that interacts with antithrombin III and activated coagulation factor X resulting in an inhibition of the coagulation system. It has been successful in doses of 2.5 mg for thromboprophylaxis as well as in higher therapeutic doses of 5-7.5 mg. No optimal method for monitoring the effects of fondaparinux has been proposed. The aim of the present study was to investigate whether a viscoelastic coagulation analyzer, the Sonoclot (Sienco, Denver, Colorado, USA), could be used for in-vitro monitoring of fondaparinux. Different concentrations of fondaparinux were added in vitro to whole blood taken from eight volunteers. The blood samples mixed with the various amounts of fondaparinux were analyzed using the Sonoclot. The whole-blood activated partial thromboplastin time with the Hemochron Jr (ITC, Edison, New Jersey, USA) was used as the reference coagulation analysis. All analyses were started expeditiously, within 30 s from sampling, and were performed at 37 degrees C. The values of the Sonoclot parameter clot rate, which measures the rate of fibrin formation, fibrin polymerization and platelet-fibrin interactions, were significantly correlated to increasing concentrations of fondaparinux (R = -0.90). The Sonoclot parameters of activated coagulation time, time to peak and clot retraction had weaker, but still significant, correlations to fondaparinux concentrations. At prophylactic doses (0.38 microg/ml blood) the clot rate decreased 15% compared with the initial unanticoagulated value, whereas at therapeutic doses (1.53 microg/ml blood) there was a 27% decrease. In conclusion, the Sonoclot parameter clot rate could be of clinical value to individualize the fondaparinux dosage, especially the higher, therapeutic, dosages.


Asunto(s)
Anticoagulantes/sangre , Pruebas de Coagulación Sanguínea/métodos , Polisacáridos/sangre , Tiempo de Coagulación de la Sangre Total/instrumentación , Tiempo de Coagulación de la Sangre Total/métodos , Anticoagulantes/uso terapéutico , Retracción del Coagulo/efectos de los fármacos , Relación Dosis-Respuesta a Droga , Fondaparinux , Humanos , Cinética , Polisacáridos/uso terapéutico , Ultrasonido , Tiempo de Coagulación de la Sangre Total/estadística & datos numéricos